05000352/LER-1999-003, Forwards LER 99-003-00,re Rps,Pcrvics Actuations.Ler Contains Special Rept Info for HPCI & Reactor Core Isolation Cooling Sys Injections Into Rv

From kanterella
Jump to navigation Jump to search
Forwards LER 99-003-00,re Rps,Pcrvics Actuations.Ler Contains Special Rept Info for HPCI & Reactor Core Isolation Cooling Sys Injections Into Rv
ML20195B202
Person / Time
Site: Limerick Constellation icon.png
Issue date: 05/19/1999
From: Gallagher M
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20195B209 List:
References
NUDOCS 9905280180
Download: ML20195B202 (1)


LER-2099-003, Forwards LER 99-003-00,re Rps,Pcrvics Actuations.Ler Contains Special Rept Info for HPCI & Reactor Core Isolation Cooling Sys Injections Into Rv
Event date:
Report date:
3522099003R00 - NRC Website

text

E i

,- Michael P. Gallagher, P.E.

  • - Plant Manager I
Umerick Generating station L

4PECO NUCLEAR

[i Pfc C Era,en A Unit of PECO Energy

  • toga. P 19464-0920

{'

610 718 2000 10CFR50.73 Tech Spec 6.9.2 May 19,1999 Docket No. 50-352 License No. NPF-39 U.S. Nuclear Regulatory Commission Attn.: Document Control Desk Washington, DC 20555 l

SUBJECT:

Licensee Event Report Limerick Generating Station - Unit 1 This LER reports Reactor Protection System (RPS) and Primary Containment and Reactor Vessel isolation Control System (PCRVICS) actuations that resulted from a loss of feedwater flow due to the spurious tripping of a breaker that supplies power to position indication to the inlet valves to the deep bed condensate demineralizer system.

This LER also contains Special Report information for the High Pressure Coolant injection and Reactor Core Isolation Cooling system injections into the reactor vessel in l response to the loss of feedwater event described above.

Reference:

Docket No. 50-352 i Report Number: 1-99-003 Revision Number: 00 Event Date: April 20,1999 Report Date May 19,1999 Facility: Limerick Generating Station P.O. Box 2300, Sanatoga, PA 19464 ,

This LER is being submitted pursuant to the requirements of 10CFR50.73(a)(2)(lv). The

.-Reporting Special Requirement Report information is being submitted pursuant to Technical Specifications 6.9.2, as required by Technical Specifications Actions 3.7.3.b and 3.5.1.f.

Very truly yours, i y /

1, . 9 I

/V cc: H. J. Miller, Administrator Region I, USNRC ,S

- A. L. Burritt, USNRC Senior Resident inspector, LGS ,

l 9905290180 990519 l PDR ADOCK 05000352

S PDR .

t1 j