ML20195B295

From kanterella
Jump to navigation Jump to search
Forwards Rev 0 to LGS Unit 2 Reload 5,Cycle 6 COLR, IAW TS Section 6.9.1.12.Values Listed Have Been Determined Using NRC-approved Methodology & Are Established Such That All Applicable Limits of Plants Safety Analysis Are Met
ML20195B295
Person / Time
Site: Limerick Constellation icon.png
Issue date: 05/20/1999
From: Geoffrey Edwards
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20195B299 List:
References
NUDOCS 9905280214
Download: ML20195B295 (1)


Text

y

. Ctation support Department A

V TS 6.9.1.12 PECO NUCLEAR- nco m.c-965 Chesterbrook Boulevard A Unit of PECO Energy Wayne. PA 190874691 May 20,1999 Docket No. 50-353 i

License No. NPF-85 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555

Subject:

Limerick Generating Station, Unit 2 issuance of the Core Operating Limits Report for Reload 5, Cycle 6, Revision 0

Dear Sir / Madam:

Enclosed is a copy of the Core Operating Limits Report (COLR) Revision 0 for Limerick Generating Station (LGS), Unit 2. Reload 5, Cycle 6. This COLR provides the cycle-specific parameter limits for; Maximum Average Planar Linear Heat Generation Rate (MAPLHGR);

Minimum Critical Power Ratio (MCPR); ARTS MCPR thermal limit adjustments and multipliers; ARTS MAPLHGR thermal limit multipliers; Rod Block Monitor (RBM) setpoints; MAPLHGR single loop operation (SLO) reduction factor; Linear Heat Generation Rate (LHGR); Turbine Bypass Valve parameters; Recirculation Pump Motor Generator (MG) Set Scoop Tube Stops; and Reactor Coolant System Recirculation Flow Upscale Trips. These values have been determined using NRC-approved methodology and are established such that all applicable limits of the plant safety analysis are met.

This COLR Revision was implemented on May 20,1999, and is being submitted to the NRC in accordance with LGS, Unit 2 Technical Specifications (TS) Section 6.9.1.12.

l' If you have any questions, please do not hesitate to contact us.

Very truly yours, Y -

arrett D. Edwards Director- Licensing Enclosure cc: (w/ encl) H. J. Miller, Administrator, Region 1, USNRC j A. L. Burritt, USNRC Senior Resident inspector, LGS 1 R. R. Janati, PA Bureau of Radiological Protection l

,.0 go D

j 9905290214 990520 l PDR ADOCK 05000353 '

P PDR ,

I