Forwards Application for Amend to Licenses DPR-42 & DPR-60, Revising Limiting Conditions for Operations & Miscellaneous Changes.Generic Action Statement Included Per Resident Inspector Recommendation.Fee Paid
ML20155A279
Person / Time
Site: Prairie Island  Xcel Energy icon.png
Issue date: 03/17/1986
From: Musolf D
NORTHERN STATES POWER CO.
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20155A284 List:
References
NUDOCS 8604080356
Download: ML20155A279 (2)


Text

r )

W Northern States Power Company 414 Nico%t mar Minneapoks. Minnesota 55401 March 17, 1986 Director Office of Nuclear Reactor Regulation U S Nuclear Regulatory Commission Washington, DC 20555 PRAIRIE ISIAND NUCLEAR GENERATING PIANT Docket Nos. 50 282 License Nos. DPR-42 50 306 DPR 60 License Amendment Request dated March 17, 1986 LCO Action Statements and Miscellaneous Changes _

Attached are three originals and thirty seven conformed copies of a request to change the Technical Specifications, Appendix A, of Operating Licenses DPR 42 and DPR-60. In accordance with 10 CFR Part 170, a check in the amount of $150.00 is enclosed.

This License Amendment Request contains a major revision to the Prairie Island Technical Specifications. Exhibit A describes the proposed changes, reasons for change and the significant hazards evaluation. Exhibit B contains the revised Technical Specification pages.

In response to a recommendation f rom the Prairie Island NRC Resident Inspector, a Technical Specification revision was initiated to incorporate a generic action statement. This generic action statement would be followed when required actions are not specified, or cannot be satisfied.

In conjunction with this revision, a thorough review of the Prairie island Technical Specifications was made to ensure th" compatibility of the generic action statement with the existing Technical Specifications.

During the course of this review it became apparent that additional improvements to action statements should be made.

Since the action statement improvements af fected a large number of Technical Specification sections, it was an ident time to also incorporata changes which would make the Technical Specifications caster for Plant and NRC personnel to use and which would reduce the potential for misinterpretat ion or human error. These changes support the ongoing human error reduction program at Prairie Island. The resulting changes include the reorganization and standardization of some sections, the removal of ambiguitics, and changes denignnd to ennure that a consintent tornat 1.

, utilized throughout the Technical Specificatlonn. Itowever, the original format of the Prairie Island Technical Specificationn was retained in order to minimize the amount of retraining f or operations personnel as well an \

others who use tha Technical Specifications. 00 b

0604000356 060317 PDR ADOCK 05000202 P PDR 0, k/CY(ICll $ &

Director of NRR Northern States Power Company March 17, 1986 Page 2 The changes noted above and other miscellaneous Technical Specification changes included in this License Amendment Request, are listed on the first page of Exhibit A.

Some of the format changes made to section 3.0 are also applicable to section 4.0. However, all pages of Section 4.0 are not included in this change, but will be revised in a future change.

Please contact us if you have any question concetning this License Am,ndment Request. Due to the magnitude of this change and it s af fect on plant procedures and training, please make this clange ef fective 90 days following it:: approval. This will allow time to complete plant procedure revision and operations personnel training.

DJ M.

David Musolf Manager - Nuclear Suppor Services DMM/EFE/tp c: Regional Administrator-III, NRC NRR Project Manager, NRC Resident Inspector, NRC MPCA Attn: F W Ferman C Charnoff Attachments: Affidavit of David Musolf Exhibit A, Evaluation of Proposed Changen Exhibit B, Proposed Changes Exhibit C, Safety Evaluation of 7.06 vs 6.9% Negative Rate Trip Setpoint Check (Attached to Director of NRR's copy) l i

-