sk.

TENNESSEE VALLEY AUTHORITY CH ATTANOOG A. TENNESSEE 374o1 .;

400 Chestnut Street Tower II July 26, 1979 . -,

c.

co C:

Mr. James P. O'Reilly, Director Office of Inspection and Enforcement y U.S. Nuclear Regulatory Co= mission Region II - Suite 3100 101 Marietta Street Atlanta, Georgia 30303

Dear Mr. O'Reilly:

SEQUOYAH NUCLEAR PLANT UNITS 1 AND 2 - STEAM GENERATOR WA REFERENCE COLUMN ERROR - NCR MEB 79 FIRST INTERIM REPORT The subject deficiency was initially reported to NRC-0IE Inspector B. W. Riley on June 29, 1979, in accordance with 10 CFR 50.55(e).

Enclosed is our first interim report. We expect to submit our next report by September 28, 1979. An identical nonconformance has been reported for Watts Bar Nuclear Plant as NCR MEB 79-33.

in touch If you have any questions concerning this matter, please get with D. L. Lambert at FIS 854-2581.

Very truly yours, TENNESSEE VALLEY AUTHORITY

. M. Mills, Manager Nuclear Regulation and Saf ety Enclosure cc: Mr. Victor Stello, Jr., Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555