ML20206C986: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
Line 2: Line 2:
| number = ML20206C986
| number = ML20206C986
| issue date = 03/27/1987
| issue date = 03/27/1987
| title = Ack Receipt of 870319 Ltr Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 70-1151/87-02
| title = Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 70-1151/87-02
| author name = Stohr J
| author name = Stohr J
| author affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
| author affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Line 11: Line 11:
| contact person =  
| contact person =  
| document report number = NUDOCS 8704130209
| document report number = NUDOCS 8704130209
| title reference date = 03-19-1987
| document type = CORRESPONDENCE-LETTERS, NRC TO VENDOR/MANUFACTURER, OUTGOING CORRESPONDENCE
| document type = CORRESPONDENCE-LETTERS, NRC TO VENDOR/MANUFACTURER, OUTGOING CORRESPONDENCE
| page count = 1
| page count = 1

Latest revision as of 14:35, 6 December 2021

Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 70-1151/87-02
ML20206C986
Person / Time
Site: Westinghouse
Issue date: 03/27/1987
From: Stohr J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Loch E
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
References
NUDOCS 8704130209
Download: ML20206C986 (1)


Text

. _ .. . .

06106)

{ Pfa 2 71987

. ~.,

Westinghouse Electric Corporatitn 4 ATTN
Mr. E. P. Loch, Manager i Columbia Plant l Commercial Nuclear Fuel Division Drawer R Columbia, SC 29250 il j Gentlemen:

SUBJECT:

NRC INSPECTION REPORT N0. 70-1151/87-02

, Thank you for your response of March 19, 1987, to our Notice of Violation, j issued on February 18, 1987, concerning activities conducted at your Columbia j facility. We have evaluated your response and found that it meets the j requirements of 10 CFR 2.201. We will examine the implementation of your corrective actions during future inspections.

We appreciate your cooperation in this matter.

Sincerely,

] .

J. Philip Stohr, Director Division of Radiation Safety and Safeguards bec: License Fee Management Branch j Document Control Desk i State of North Carolina I

i I

l ffi g Rll jA'-l gaff l Cliosey DCollins E e ine v 3/g/87 3/g7/87 3 87 3 87 ' [ 7 l

i 0704130209 070327 1

} PDR ADOCK 0700 C

l!

s\0 reoq