,s e/                              TENNESSEE VALLEY AUTHORITY Sequoyah Nuclear Plant Post Office Box 2000 Soddy-Daisy, Tennesseo 37379 October 28, 1988 U.S. Nuclear Regulatory Comission Document Control Desk                                                                    ,
Washington, DC 20555 l
Gentle <nen TENNESSEE VALLEY AUTHORITY - SEQUOYAH NUCLEAR PLANT UNIT 1 - DOCKET NOS.
l 50-327 - FACILITY OPERATING LICENSE DPR-77 REPORTABLE OCCU''2ENCE REPORT SQRO-50-327/88036 I
l          The enclosed licensee event report provides details concerning a unit 1 l          reactor trip sig3al resulting from a steam flow to feedwater flow mismatch I
with low steam generator level signal which was caused by a breakdown of management systema and procedural inadequacy. This event is being reported in accordance with 10 CFR 50.73, paragraph a.2.Lv.
Very truly yours.
l          TENNESSEE VALLEY AUTHORITY S.    . ., i t                                                                            :
P1 nt Manager llRR:JDS PAL Er.c losure cc (Enclosure):
J. Nelson Crace, Regional Administrator            RIMS, MR 4N 72A-C U. S. Nuclear Regulatory Comission                M. A. Cooper, O&PS-4, SQN Suite 2900                                        R. D. Erickson, PRS, BFN 101 Marietta Street, NW                            R. L. Cridley, LP SN 1578-C Atlanta, Georgia 30323                                (Attention: D. E. McCloud)
(Attention: R. ii. Shell)
Records Center                                    W. H. Hannum, BR IN 77B-C Institute of Nuclear Power Operations              P. G. Trvdel, DSC-E, SQN Suite 1500                                        R. J. Johnson, POTC 1100 circle 75 Parkway                                (Attention: C. H. Noe)
Atlanta, Georgia 30339                            J. L. McAnally, LP SS 83E-C Ceorge Toto Site Director, WBN I              NRC Inspector, Sequoyah Nuclear Plant            J. S. Woods, PRS, WBN M. K. Sasser, PRS, WBN 1
i 8811070248 S31028 PDR    ADOCK 05000327 def
                                                                                                /
g                    P Dt..
go An E vat 0;;xv tun.ty Employer}}

Latest revision as of 17:08, 16 December 2020

Forwards LER Providing Details Re Reactor Coolant Trip Resulting from Steam Flow to Feedwater Flow Mismatch.Caused by Breakdown of Mgt Sys & Procedural Inaddequacy.W/O LER
ML20195E131
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 10/28/1988
From: Shawn Smith
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
NUDOCS 8811070248
Download: ML20195E131 (1)


Text

3s 4 '

,s e/ TENNESSEE VALLEY AUTHORITY Sequoyah Nuclear Plant Post Office Box 2000 Soddy-Daisy, Tennesseo 37379 October 28, 1988 U.S. Nuclear Regulatory Comission Document Control Desk ,

Washington, DC 20555 l

Gentle <nen TENNESSEE VALLEY AUTHORITY - SEQUOYAH NUCLEAR PLANT UNIT 1 - DOCKET NOS.

l 50-327 - FACILITY OPERATING LICENSE DPR-77 REPORTABLE OCCU2ENCE REPORT SQRO-50-327/88036 I

l The enclosed licensee event report provides details concerning a unit 1 l reactor trip sig3al resulting from a steam flow to feedwater flow mismatch I

with low steam generator level signal which was caused by a breakdown of management systema and procedural inadequacy. This event is being reported in accordance with 10 CFR 50.73, paragraph a.2.Lv.

Very truly yours.

l TENNESSEE VALLEY AUTHORITY S. . ., i t  :

P1 nt Manager llRR:JDS PAL Er.c losure cc (Enclosure):

J. Nelson Crace, Regional Administrator RIMS, MR 4N 72A-C U. S. Nuclear Regulatory Comission M. A. Cooper, O&PS-4, SQN Suite 2900 R. D. Erickson, PRS, BFN 101 Marietta Street, NW R. L. Cridley, LP SN 1578-C Atlanta, Georgia 30323 (Attention: D. E. McCloud)

(Attention: R. ii. Shell)

Records Center W. H. Hannum, BR IN 77B-C Institute of Nuclear Power Operations P. G. Trvdel, DSC-E, SQN Suite 1500 R. J. Johnson, POTC 1100 circle 75 Parkway (Attention: C. H. Noe)

Atlanta, Georgia 30339 J. L. McAnally, LP SS 83E-C Ceorge Toto Site Director, WBN I NRC Inspector, Sequoyah Nuclear Plant J. S. Woods, PRS, WBN M. K. Sasser, PRS, WBN 1

i 8811070248 S31028 PDR ADOCK 05000327 def

/

g P Dt..

go An E vat 0;;xv tun.ty Employer