November 10, 2016 ULNRC-06330 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC20555-0001 10 CFR 50.7l(e) 10 CFR 54.37(b) 10 CFR 50.4(b)(6) | November 10, 2016 ULNRC-06330 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC20555-0001 10 CFR 50.7l(e) 10 CFR 54.37(b) 10 CFR 50.4(b)(6) | ||
Ladies and Gentlemen: | Ladies and Gentlemen: | ||
DOCKET NUMBER 50-483 CALLAWAY PLANT UNIT 1 UNION ELECTRIC CO. | DOCKET NUMBER 50-483 CALLAWAY PLANT UNIT 1 UNION ELECTRIC CO. | ||
RENEWED FACILITY OPERATING LICENSE NPF-30 FINAL SAFETY ANALYSIS REPORT REVISION OL-22 ANDTECHNICAL SPECIFICATION BASES REVISION 13 In accordance with the requirements of 10 CFR 50.71(e) and 10 CFR 50.4(b)(6), Union Electric Company (Ameren Missouri) herewith submits the Callaway Plant Final Safety Analysis Report (FSAR) (Standard Plant and Site Addendum) updated through Revision OL-22. The FSAR has been revised to include changes made to the plant up to 6 months prior to the date of this filing. | RENEWED FACILITY OPERATING LICENSE NPF-30 FINAL SAFETY ANALYSIS REPORT REVISION OL-22 ANDTECHNICAL SPECIFICATION BASES REVISION 13 In accordance with the requirements of 10 CFR 50.71(e) and 10 CFR 50.4(b)(6), Union Electric Company (Ameren Missouri) herewith submits the Callaway Plant Final Safety Analysis Report (FSAR) (Standard Plant and Site Addendum) updated through Revision OL-22. The FSAR has been revised to include changes made to the plant up to 6 months prior to the date of this filing. | ||
Line 32: | Line 30: | ||
Ameren Missouri has reviewed Revision OL-22 of the FSAR for sensitive information. Consequently, Revision OL-22 of the FSAR is being provided on two CD-ROMs (CDs). One version, ori CD 1 (provided as Enclosure 2), is a complete text of the FSAR and contains sensitive information which should be withheld from public disclosure per the guidance in RIS 2015-17. The information that Ameren Missouri has identified to be withheld is designated by the statement "Withhold per RIS 2015-17" at the top and bottom of the page. The second version, on CD 2 (provided as Enclosure 3), | Ameren Missouri has reviewed Revision OL-22 of the FSAR for sensitive information. Consequently, Revision OL-22 of the FSAR is being provided on two CD-ROMs (CDs). One version, ori CD 1 (provided as Enclosure 2), is a complete text of the FSAR and contains sensitive information which should be withheld from public disclosure per the guidance in RIS 2015-17. The information that Ameren Missouri has identified to be withheld is designated by the statement "Withhold per RIS 2015-17" at the top and bottom of the page. The second version, on CD 2 (provided as Enclosure 3), | ||
is a redacted text of the FSAR. Each page on which information was withheld contains the | is a redacted text of the FSAR. Each page on which information was withheld contains the | ||
***************************************************************************************************************************** PO Box 620 Fulton, MO 65251 . AmerenMissouri.com ************** | ***************************************************************************************************************************** PO Box 620 Fulton, MO 65251 . AmerenMissouri.com ************** | ||
***************************************************************************************************************************** : STARS~ Alliance | ***************************************************************************************************************************** : STARS~ Alliance | ||
ULNRC-06330 November 10, 2016 Page2 designation "Withheld per RIS 2015-17." The version on CD 2 is therefore suitable for public disclosure. | ULNRC-06330 November 10, 2016 Page2 designation "Withheld per RIS 2015-17." The version on CD 2 is therefore suitable for public disclosure. | ||
Line 121: | Line 111: | ||
Attachment 1 to Enclosure 1 to ULNRC-06330 Attachment 1 The following tables contain the newly identified components and structures requiring aging management and provide how the effects of aging are managed so that the intended functions are effectively maintained during the period of extended operation. | Attachment 1 to Enclosure 1 to ULNRC-06330 Attachment 1 The following tables contain the newly identified components and structures requiring aging management and provide how the effects of aging are managed so that the intended functions are effectively maintained during the period of extended operation. | ||
Table 1 Alternate Emergency Power System Aging Management Review | Table 1 Alternate Emergency Power System Aging Management Review | ||
.. '*' *' : A9i!1g*Effect | .. '*' *' : A9i!1g*Effect | ||
... '. .. '"" ; | ... '. .. '"" ; | ||
>/' . 'r,,, | >/' . 'r,,, | ||
Line 130: | Line 118: | ||
* :Req"uirin'g * *~ging 1V1ana~ementP..rogi"arn .' | * :Req"uirin'g * *~ging 1V1ana~ementP..rogi"arn .' | ||
F,u*n~tion 111* * | F,u*n~tion 111* * | ||
.Internal/External.:" . ' . ' | .Internal/External.:" . ' . ' | ||
**Mari'agi~ment. * | **Mari'agi~ment. * | ||
' ,~ | ' ,~ | ||
; | ; | ||
. .. . ,* . ' \" . , ,. *'', | . .. . ,* . ' \" . , ,. *'', | ||
/ ,' '* *' | / ,' '* *' | ||
Loss of Preload Closure Bolting PB Carbon Steel Plant Indoor Air (Ext) Bolting Integrity (FSAR SP 19.1.8) | Loss of Preload Closure Bolting PB Carbon Steel Plant Indoor Air (Ext) Bolting Integrity (FSAR SP 19.1.8) | ||
Loss of Material External Surfaces Monitoring of Plant Indoor Air (Ext) Loss of Material Mechanical Components Damper PB Carbon Steel (FSAR SP 19.1.21) | Loss of Material External Surfaces Monitoring of Plant Indoor Air (Ext) Loss of Material Mechanical Components Damper PB Carbon Steel (FSAR SP 19.1.21) | ||
Line 156: | Line 136: | ||
Attachment 1 to Enclosure 1 to ULNRC-06330 Alternate Emergency Power System Aging Management Review | Attachment 1 to Enclosure 1 to ULNRC-06330 Alternate Emergency Power System Aging Management Review | ||
; .. ), ' ",~ " ,, *\', ,<< | ; .. ), ' ",~ " ,, *\', ,<< | ||
~rivfi*?~m~nts. | ~rivfi*?~m~nts. | ||
* | * | ||
Line 164: | Line 143: | ||
Material .. . | Material .. . | ||
." ; | ." ; | ||
~eCluiring " Aging Management Program | ~eCluiring " Aging Management Program | ||
,')., | ,')., | ||
Function* 111 | Function* 111 | ||
.. lnt~r'nal/External ** .. '.~ . 1 | .. lnt~r'nal/External ** .. '.~ . 1 | ||
,." "'- /,, < I**/ ** | ,." "'- /,, < I**/ ** | ||
l'' | l'' | ||
{' | {' | ||
.Management '*/* | .Management '*/* | ||
*;. ""* ; | *;. ""* ; | ||
Closed Cycle Cooling Hardening and Loss Inspection of Internal Surfaces in Water (Int) of Strength Miscellaneous Piping and Ducting Components (FSAR SP 19.1.23) | Closed Cycle Cooling Hardening and Loss Inspection of Internal Surfaces in Water (Int) of Strength Miscellaneous Piping and Ducting Components (FSAR SP 19.1.23) | ||
Hardening and Loss Inspection of Internal Surfaces in Fuel Oil (Int) of Strength Miscellaneous Piping and Ducting Flexible Hoses PB Elastomer Components (FSAR SP 19.1.23} | Hardening and Loss Inspection of Internal Surfaces in Fuel Oil (Int) of Strength Miscellaneous Piping and Ducting Flexible Hoses PB Elastomer Components (FSAR SP 19.1.23} | ||
Line 194: | Line 163: | ||
Loss of Material HT, PB - Copper Alloy Lubricating Oil Analysis Lubricating Oil (Ext) Loss of Material (FSAR SP 19.1.24) | Loss of Material HT, PB - Copper Alloy Lubricating Oil Analysis Lubricating Oil (Ext) Loss of Material (FSAR SP 19.1.24) | ||
One-Time Inspection (FSAR SP 19.1.18) 7 to Enclosure 1 to ULNRC-06330 Alternate Emergency Power System Aging Management Review | One-Time Inspection (FSAR SP 19.1.18) 7 to Enclosure 1 to ULNRC-06330 Alternate Emergency Power System Aging Management Review | ||
,. * ,,,,. ~ , .*. A~* in.*.g;*. E.,,ff.ect | ,. * ,,,,. ~ , .*. A~* in.*.g;*. E.,,ff.ect | ||
,~-. | ,~-. | ||
*. ,.Envirqnments.: , .. . , > ,' . '* * '" * ** | *. ,.Envirqnments.: , .. . , > ,' . '* * '" * ** | ||
* * . | * * . | ||
Line 221: | Line 188: | ||
:*:f:.~n~tion(il : . c.: Mate~iaf . .. " ln~e~n~I /External | :*:f:.~n~tion(il : . c.: Mate~iaf . .. " ln~e~n~I /External | ||
. *: Man~g.em,en,t ,, * * . .* . . >* .* .' ** | . *: Man~g.em,en,t ,, * * . .* . . >* .* .' ** | ||
;: , ... , .., ' . . J ' | ;: , ... , .., ' . . J ' | ||
.:: ' " '.,'* .~ ~*'. " *. ,, , | .:: ' " '.,'* .~ ~*'. " *. ,, , | ||
Line 246: | Line 212: | ||
Attachment 1 to Enclosure 1 to ULNRC-06330 Alternate Emergency Power System Aging Management Review | Attachment 1 to Enclosure 1 to ULNRC-06330 Alternate Emergency Power System Aging Management Review | ||
.. AgingEffect Envir~nm~nts. 1 * * * * * | .. AgingEffect Envir~nm~nts. 1 * * * * * | ||
. componenttyp~ | . componenttyp~ | ||
Line 276: | Line 241: | ||
Attachment 1 to Enclosure 1 to ULNRC-06330 Alternate Emergency Power System Aging Management Review I | Attachment 1 to Enclosure 1 to ULNRC-06330 Alternate Emergency Power System Aging Management Review I | ||
,, : ' '"*'' ;i | ,, : ' '"*'' ;i | ||
, *.lnt~nded. * | , *.lnt~nded. * | ||
Line 285: | Line 246: | ||
*Environments, ' -- . ~ | *Environments, ' -- . ~ | ||
Agin9E1'.fect. ,. '* | Agin9E1'.fect. ,. '* | ||
'l ' | 'l ' | ||
*comporientType*:. '. | *comporientType*:. '. | ||
'' ** * ' '11 :Material* '' | '' ** * ' '11 :Material* '' | ||
. * .Requiring . . .:Ag.ing Management Program* | . * .Requiring . . .:Ag.ing Management Program* | ||
l | l | ||
* > fun~t1on | * > fun~t1on | ||
( .* "* **Internal /;External . | ( .* "* **Internal /;External . | ||
* ~"Management. **.. ' | * ~"Management. **.. ' | ||
" ..: :>**' :.,; " " .:<< ... :' .\," | " ..: :>**' :.,; " " .:<< ... :' .\," | ||
Atmosphere/ Weather Structures Monitoring Loss of material | Atmosphere/ Weather Structures Monitoring Loss of material | ||
{Structural) {Ext) {FSAR SP 19.1.31) | {Structural) {Ext) {FSAR SP 19.1.31) |
Revision as of 22:53, 4 February 2020
ML16334A025 | |
Person / Time | |
---|---|
Site: | Callaway ![]() |
Issue date: | 11/10/2016 |
From: | Wink R Ameren Missouri |
To: | Document Control Desk, Office of Nuclear Reactor Regulation |
References | |
ULNRC-06330 | |
Download: ML16334A025 (22) | |
Text
\. ': ,* .
-~rt_.
VIAmeren Callaway Plant MISSOURI