Enclosure 2 to ULNRC-06766 September 8, 2022 Page 1 of4 ATTACHMENT 2 RETYPED TS PAGES FOR TS 3.6.8 to ULNRC-06766 September 8, 2022 Page 2 of 4 Containment Sumps 3.6.8 3.6 CONTAINMENT SYSTEMS 3.6.8 Containment Sumps LCO 3.6.8 Two containment sumps shall be OPERABLE.

APPLICABILITY:

MODES I

, 2, 3, and 4.

ACTIONS CONDITION REQUIRED ACTION COMPLETION A.

One or more containment A.1 Initiate actions to reduce Immediately sumps inoperable due to containment accident containment accident generated and generated and transported transported debris.

debris exceeding the analyzed limits.

A.2 Perform SR 3.4. 1 3. 1 Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> AND A.3 Restore the containment 90 days sump(s) to OPERABLE status.

continuea CALLAWAY PLANT 3.6-24 Amendment No. 228 to ULNRC-06766 September 8, 2022 Page 3 of 4 Containment Sumps 3.6.8 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION B.

One or more containment B.J NOTES sumps inoperable for I

Enter applicable reasons other than Conditions and Condition A.

Required Actions of LCO 3.5.2, ECCS Operating, and LCO 3.5.3, ECCS Shutdown, for emergency core cooling trains made inoperable by the containment sump(s).

2.

Enter applicable Conditions and Required Actions of LCO 3.6.6, Containment Spray and Cooling Systems, for containment spray trains made inoperable by the containment sump(s).

Restore the containment 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> sump(s) to OPERABLE status.

C.

Required Action and C.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Timenotmet.

AND C.2 Be in MODE 5.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> CALLAWAY PLANT 3.6-25 Amendment No. 228 to ULNRC-06766 September 8, 2022 Page 4 of4 Containment Sumps 3.6.8 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.6.8.1 Verify, by visual inspection, the containment sumps do In accordance with not show structural damage, abnormal corrosion, or the Surveillance debris blockage.

Frequency Control Program CALLAWAY PLANT 3.6-26 Amendment No. 228