Line 3: |
Line 3: |
| | issue date = 12/18/1992 | | | issue date = 12/18/1992 |
| | title = Acceptance Criteria for ECCS in Light Water Nuclear Power Reactors, Annual Rept for CY92 | | | title = Acceptance Criteria for ECCS in Light Water Nuclear Power Reactors, Annual Rept for CY92 |
| | author name = PLUNKETT T F | | | author name = Plunkett T |
| | author affiliation = FLORIDA POWER & LIGHT CO. | | | author affiliation = FLORIDA POWER & LIGHT CO. |
| | addressee name = | | | addressee name = |
Revision as of 09:07, 18 June 2019
|
---|
Category:ANNUAL OPERATING REPORT
MONTHYEARML20217B9871999-04-0808 April 1999 Changes,Tests & Experiments Made as Allowed by 10CFR50.59 for Period Covering 971014-990408 ML17354A8851997-10-13013 October 1997 FPL Units 3 & 4 Changes,Tests & Experiments Made as Allowed by 10CFR50.59 for Period Covering 960408-971013. ML17354A4181996-12-31031 December 1996 Radiation Exposure Monitoring & Access Control Sys - Remacs Statistical Whole Body Exposure Rept. ML17352B1661994-12-0101 December 1994 Changes,Tests & Experiments Made as Allowed by 10CFR50.59 for Period 930601-941201. W/950512 Ltr ML17352A3021993-11-18018 November 1993 Annual 10CFR50.59 Rept on Changes Test & Experiments for 920701-930601.W/931118 Ltr ML17349A5601992-12-18018 December 1992 Acceptance Criteria for ECCS in Light Water Nuclear Power Reactors, Annual Rept for CY92 ML17349A3661992-06-30030 June 1992 Annual 10CFR50.59 Rept of Changes,Tests & Experiments for Jan-June 1992. W/920829 Ltr ML17348B0931991-06-30030 June 1991 Rept on Changes,Tests & Experiments Made W/O Prior Commission Approval for Period 900701-910630.W/910830 Ltr ML17348A5421990-06-30030 June 1990 Changes,Tests & Experiments Made as Allowed by 10CFR50.59 for Period of Jul 1989 - June 1990. W/900830 Ltr L-89-316, Changes,Tests & Experiments Made as Allowed by 10CFR50.59 for Period of Jul 1988 - June 19891989-06-30030 June 1989 Changes,Tests & Experiments Made as Allowed by 10CFR50.59 for Period of Jul 1988 - June 1989 L-88-366, Changes,Tests & Experiments Made W/O Prior Commission Approval for Jul 1987 - June 19881988-06-30030 June 1988 Changes,Tests & Experiments Made W/O Prior Commission Approval for Jul 1987 - June 1988 L-87-365, Changes,Tests & Experiments Made W/O Prior Commission Approval,For Jul 1986 - June 19871987-06-30030 June 1987 Changes,Tests & Experiments Made W/O Prior Commission Approval,For Jul 1986 - June 1987 ML20215K0501986-06-30030 June 1986 Changes,Tests & Experiments Made W/O Prior Commission Approval for Period Jul 1985 - June 1986 L-85-347, Changes,Tests & Experiments Made W/O Prior Commission Approval for Jul 1984 - June 1985, Per 10CFR50.59(b).Related Info Encl1985-06-30030 June 1985 Changes,Tests & Experiments Made W/O Prior Commission Approval for Jul 1984 - June 1985, Per 10CFR50.59(b).Related Info Encl L-84-224, Rept of Changes,Tests & Experiments Made W/O Prior Commission Approval,Jul 1983 - June 19841984-06-30030 June 1984 Rept of Changes,Tests & Experiments Made W/O Prior Commission Approval,Jul 1983 - June 1984 L-83-479, Annual Rept on Changes,Tests & Experiments Made W/O Prior Commission Approval from Jul 1982 - June 19831983-06-30030 June 1983 Annual Rept on Changes,Tests & Experiments Made W/O Prior Commission Approval from Jul 1982 - June 1983 ML17338A2101978-07-31031 July 1978 Fifth-yr Surveillance Rept of Containment Structure post- Tensioning Sys.Info Includes Wire Testing & Analysis of Sheath Filter 1999-04-08
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML20217L9371999-10-20020 October 1999 Safety Evaluation Supporting Licensee Proposed Alternative from Certain Requirements of ASME Code,Section XI for First 10-Yr Interval Request for Relief for Containment Inservice Insp Program ML17355A4471999-09-30030 September 1999 Monthly Operating Repts for Sept 1999 for Turkey Point,Units 3 & 4.With 991008 Ltr ML17355A4121999-08-31031 August 1999 Monthly Operating Repts for Aug 1999 for Turkey Point,Units 3 & 4.With 990909 Ltr ML17355A3981999-07-31031 July 1999 Monthly Operating Repts for July 1999 for Turkey Point,Units 3 & 4.With 990809 Ltr ML17355A3891999-07-20020 July 1999 LER 99-001-00:on 990623,manual Rt from 100% Power Following Multiple Control Rod Drops Was Noted.Caused by Manual Action Taken by Reactor Control Operator.Inspected & Repaired Stationary Gripper Regulating Cards.With 990720 Ltr ML17355A3841999-06-30030 June 1999 Monthly Operating Repts for June 1999 for Turkey Point,Units 3 & 4.With 990713 Ltr ML17355A3681999-06-30030 June 1999 Revised Update to Topical QA Rept, Dtd June 1999 ML17355A3611999-06-30030 June 1999 Refueling Outage ISI Rept. ML17355A3511999-05-31031 May 1999 Monthly Operating Repts for May 1999 for Turkey Point,Units 3 & 4.With 990609 Ltr ML17355A3331999-04-30030 April 1999 Monthly Operating Repts for Apr 1999 for Turkey Point,Units 3 & 4.With 990511 Ltr ML20217B9871999-04-0808 April 1999 Changes,Tests & Experiments Made as Allowed by 10CFR50.59 for Period Covering 971014-990408 ML17355A2881999-04-0505 April 1999 COLR for Turkey Point Unit 4 Cycle 18. ML17355A2911999-03-31031 March 1999 Monthly Operating Repts for Mar 1999 for Turkey Point,Units 3 & 4.With 990414 Ltr ML17355A2551999-02-28028 February 1999 Monthly Operating Repts for Feb 1999 for Turkey Point Nuclear Power Plant,Units 3 & 4.With 990315 Ltr ML17355A2261999-01-31031 January 1999 Monthly Operating Repts for Jan 1999 for Turkey Point,Units 3 & 4.With 990211 Ltr ML17355A2201999-01-20020 January 1999 Refueling Outage ISI Rept. ML17355A1911998-12-31031 December 1998 Monthly Operating Repts for Dec 1998 for Turkey Point,Units 3 & 4.With 990112 Ltr ML18008A0461998-11-30030 November 1998 Monthly Operating Repts for Nov 1998 for Turkey Point,Units 3 & 4.With 981209 Ltr ML17354B1921998-11-18018 November 1998 LER 98-007-00:on 981020,containment Purge Supply,Valve Opened Wider than TS Limit.Caused by Improper Setting of Mechanical Stops.Incorporated Improved Standard Method of Measuring Angular Valve Position Into Sp.With 981118 Ltr ML17354B1891998-11-0909 November 1998 Simulatory Certification Update 2. ML17354B1901998-10-31031 October 1998 Monthly Operating Repts for Oct 1998 for Turkey Point,Units 3 & 4.With 981112 Ltr ML17354B1591998-10-23023 October 1998 COLR for Turkey Point Unit 3 Cycle 17. ML17354B1361998-10-16016 October 1998 LER 98-004-00:on 980921,automatic Reactor Trip Occurred. Caused by Inadequate re-correlation of Intermediate Range Neutron Flux Instrumentation Reactor Trip Bistable. Enhanced Applicable Plant Procedures.With 981016 Ltr ML17354B1311998-09-30030 September 1998 Monthly Operating Repts for Sept 1998 for Turkey Point Unit 3 & 4.With 981012 Ltr ML17354B0971998-09-0909 September 1998 Part 21 Rept Re Possible Machining Defect in Certain One Inch Stainless Steel Swagelok Front Ferrules,Part Number SS-1613-1.Caused by Tubing Slipping Out of Fitting at Three Times Working Pressure of Tubing.Notified Affected Utils ML17354B0981998-08-31031 August 1998 Monthly Operating Repts for Aug 1998 for Turkey Points,Units 3 & 4.With 980915 Ltr ML17354B0771998-07-31031 July 1998 Monthly Operating Repts for July 1998 for Turkey Point,Units 3 & 4.W/980810 Ltr ML17354B0341998-07-15015 July 1998 LER 98-003-00:on 980619,discovered That Auxiliary Feedwater Sys Was Inoperable Due to Inadequate Inservice Testing of Valves.Caused by Misunderstanding of Testing Criteria.Util Revised Procedures & Verified Operability of Valves ML17354B0241998-06-30030 June 1998 Monthly Operating Repts for June 1998 for Turkey Point,Units 3 & 4.W/980709 Ltr ML17354B0171998-06-29029 June 1998 Rev 1 to PTN-FPER-97-013, Evaluation of Turbine Lube Oil Fire. ML17354A9841998-06-18018 June 1998 LER 97-007-01:on 970730,automatic Reactor Trip Occurred Due to Closure of B Msiv.Caused by Failed BFD22S Relay.Six Relays on 3A,3B & 3C MSIVs Were Replaced & Implemented Plant Change to Disable Electronic Trip Function on 3 AFW Pumps ML17354A9741998-06-0909 June 1998 LER 98-002-00:on 980513,discovered Potential LOCA-initiated Electrical Fault Which Places ECCS Outside Design Basis. Caused by Inadequate Review of Effect on non-safety Circuit failures.Re-powered PC-*-600A Relays ML20248F7441998-05-31031 May 1998 Reactor Vessel Working Group,Response to RAI Regarding Reactor Pressure Vessel Integrity ML17354A9711998-05-31031 May 1998 Monthly Operating Repts for Turkey Point,Units 3 & 4. W/980611 Ltr ML17354A9231998-04-30030 April 1998 Monthly Operating Repts for Apr 1998 for Turkey Point,Units 3 & 4.W/980511 Ltr ML17354A8821998-03-31031 March 1998 Monthly Operating Repts for Mar 1998 for Turkey Point,Units 3 & 4.W/980409 Ltr ML17354A8511998-03-24024 March 1998 LER 97-009-01:on 971114,discovered That CR Console Switch for 3B Sgfp Was Not in Start Position.Caused by Inadequate Procedural Guidance.Revised Procedures 3/4-OP-074,informed Personnel of Event & Performed Walkdown of CR ML17354B0001998-03-18018 March 1998 Florida Power & Light Topical Quality Asurance Rept, Dtd June 1998 ML17354A8441998-03-18018 March 1998 LER 98-001-00:on 980216,manual Reactor Trip Occurred Due to Loss of Turbine Control Oil Pressure W/Steam Leak in Auxiliary Feedwater Steam Supply Piping.Auxiliary Governor Maint Instructions Will Be revised.W/980318 Ltr ML17354A8311998-02-28028 February 1998 Monthly Operating Repts for Feb 1998 for Turkey Point,Units 3 & 4.W/980311 Ltr ML17354A7871998-01-31031 January 1998 Monthly Operating Repts for Jan 1998 for Turkey Point,Units 3 & 4.W/980209 Ltr ML17354A7581997-12-31031 December 1997 Monthly Operating Repts for Dec 1997 for Turkey Point,Unit 3 & 4.W/980112 Ltr ML17354A7361997-12-12012 December 1997 LER 97-009-01:on 971114,identified That CR Console Switch for 3B SG Feedwater Pump Was Not in Start Position.Caused by Inadequate Procedural Guidance.Procedures 3/4-OP-074,SGFP Were revised.W/971212 Ltr ML17354A7381997-11-30030 November 1997 Monthly Operating Repts for Nov 1997 for Turkey Point,Units 3 & 4.W/971215 Ltr ML17354A7211997-10-31031 October 1997 Monthly Operating Repts for Oct 1997 for Turkey Point,Units 3 & 4.W/971114 Ltr ML17354A7491997-10-13013 October 1997 SG Insp Rept. ML17354A8851997-10-13013 October 1997 FPL Units 3 & 4 Changes,Tests & Experiments Made as Allowed by 10CFR50.59 for Period Covering 960408-971013. ML17354A6801997-10-0808 October 1997 LER 97-008-00:on 970909,containment Sump Debris Screens Outside Design Basis Due to Stress Damage Was Discovered. Caused by Inadequate Procedural Guidance & Personnel Error. Discrepancies Found on Screens corrected.W/971008 Ltr ML17354A6791997-10-0606 October 1997 COLR Unit 4 Cycle 17, for Turkey Point ML17354A6811997-09-30030 September 1997 Monthly Operating Repts for Sept 1997 for Turkey Point,Units 3 & 4.W/971009 Ltr 1999-09-30
[Table view] |
Text
ACCEI ERAT DOCUMENT DISTR UTION SYSTEM REGULATO INFORMATION DISTRIBUTION STEM (RIDS)ACCESSION NBR:9212280161 DOC.DATE: 92/12/18 NOTARIZED:
NO FACIE:50-250 Turkey Point Plant, Unit 3, Florida Power and Light C 50-251 Turkey Point Plant, Unit 4, Florida Power and Light C AUTH.NAME AUTHOR AFFILIATION PLUNKETT,T.F.
Florida Power&Light Co.RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)
SUBJECT:
"Acceptance Criteria for ECCS in Light Water Nuclear Power Reactors," annual rept for CY92.DISTRIBUTION CODE: AOOID COPIES RECEIVED:LTR i ENCL i SIZE: 5 TITLE: OR Submittal:
General Distribution DOCKET 05000250 05000251 R D NOTES NRR RAGHAVAN P L NRR RAGHAVAN,L 05000250/05000251 RECIPIENT ID CODE/NAME PD2-2 LA AULUCKiR INTERNAL: NRR/DET/ESGB NRR/DST/SELB 7E NRR/DST/SRXB 8E OC LFMB-~EM Ol EXTERNAL: NRC PDR NOTES: COPIES LTTR ENCL 1 1 2 2 1 1 1 1 1 1 1 0 1 1 1 1 1 1 RECIPIENT ID CODE/NAME PD2-2 PD NRR/DOEA/OTSB11 NRR/DST/SICB8H7 NUDOCS-ABSTRACT OGC/HDS3 RES/DSIR/EIB NSIC COPIES LTTR ENCL 1.1 1 1 1 1 1 1 1 0 1 1 1 1 D D D D NOTE TO ALL"RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTE!CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT.504-2065)TO ELIMINATE YOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!D TOTAL NUMBER OF COPIES REQUIRED: LTTR 17 ENCL 15
'Il~'
P.O.Box 029100, Miami, FL, 33102-9100 OIS 18'(992 L-92-338 10 CFR 50.46 U.S.Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C.20555 Re: Turkey Point Units 3 and 4 Docket Nos.50-250 and 50-251 10 CFR 50.46,"Acceptance Criteria for Emergency Core Cooling Systems In Light Water Nuclear Power Reactors"-Annual Re ort Gentlemen:
10 CFR 50.46 (a)(3)(ii) requires that licensees report to the Commission at least annually the nature of changes to, or errors discovered in, the emergency core cooling system (ECCS)evaluation models, or in the application of such models that affect the peak clad temperature calculation and their effect on the limiting ECCS analysis.This letter provides Florida Power and Light Company's report for Turkey Point Units 3 and 4 for calendar year 1992.Should there be any questions, please contact us.Very truly yours, Wr.7/~EH 8 T.F.Plunkett Vice President.
Turkey Point Nuclear Attachment TFP/RJT/rjt cc: Stewart D.Ebneter, Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, Turkey Point Plant r;~OO'zs 9212280ibi 9212i8 PDR ADQCK 05000250 R PDR an FPL Group company g0 c'-92-338 Attachment Page 1 ATTACHMENT Re: Turkey Point Units 3 and 4 Docket Nos.50-250 and 50-251 10 CFR 50.46,"Acceptance Criteria for Emergency Core Cooling Systems In Light Water Nuclear Power Reactors" Annual Re ort Lar e Break IOCA LBLOCA By letter L-91-165 dated June 7, 1991'lorida Power and Light Company (FPL)reported a peak clad temperature of 2132'F in the event of a worst case large break loss of coolant accident (LBLOCA)transients This value included a calculated peak temperature of 2082'F plus 50 F increment due to containment purge coincident with a LBLOCA, increased steady-state pressurizer pressure uncertainty band, transition fuel core penalty, implementation of debris resistant fuel assemblies and stainless steel rods in fuel assemblies, and steam generator tube collapse during an earthquake.
Recent corrections to LBLOCA modelling have resulted in a decrease in the peak clad temperature for the worst case LBLOCA of 3'F for a total of 2129'F.This 3 F benefit is a result of a revision in the grid loss coefficients for the Optimized Fuel Assemblies (OFA).The LBLOCA analysis as de'scribed in the Updated Final Safety Analysis Report (UFSAR)was performed by Westinghouse in 1991 using the BART computer model with fuel assembly spacer grids.Small Break LOCA SBLOCA By letter L-91-165, Florida Power and Light Company reported a peak clad temperature of 1749'F in the event of a worst case small break loss of coolant accident (SBLOCA)transient.
This value was based upon a new Turkey Point SBLOCA analysis performed by Westinghouse in 1991 using the NOTRUMP digital computer code.Recent plant changes and corrections in SBLOCA coding have resulted in a decrease in the peak clad temperature for the worst case SBLOCA of 33'F for a total of 1716'F.This value includes a 2'F increase due to the presence of stainless steel rods in fuel assemblies, and a 35'F benefit due to a NOTRUMP Bessel function correction.
C L-92-338 Attachment Page 2~Summa+The revised peak clad temperatures of 2129'F for the worst case LBLOCA and 1716'F for the worst case SBLOCA, correcting for the effects discussed herein and summarized in the enclosed Tables 1 and 2, are below the 10 CFR 50.46 acceptance limit of 2200'F.
L-92-338 Attachment Page 3 TABLE 1 TURKEY POINT UNITS 3 AND 4 PREDICTED PEAK CLAD TEMPERATURES CURRENT LBLOCA EVALUATIONS THAT HAVE ASSESSED PCT PENALTIES Analysis of Record Evaluations s ecified in FPL letter L-91-165 2082'F Effect of Containment Purging Pressurizer Pressure Uncertainty Implementation of Debris Resistant FA Transition Core Penalty Stainless Steel Rods in Fuel Assemblies Steam Generator Tube Collapse During an Earthquake Total LBLOCA PCT specified in FPL Letter L-91-165 9 F 8oF 3 F 10 F 18oF 2 F 2132'F Evaluations since issuance of FPL letter L-91-165 Increase Core Pressure Drop Total Estimated LBLOCA PCT 3 F 2129'F L-92-338 Attachment Page 4 TABLE 2 TURKEY POINT UNITS 3 AND 4 PREDICTED PEAK CLAD TEMPERATURES CURRENT SBLOCA EVALUATIONS THAT HAVE ASSESSED PCT PENALTIES Analysis of Record Evaluations since issuance of L-91-165 Stainless Steel Rods-Cycle 12 Fuel NOTRUMP Bessel Function Correction Tota1 Estimated SBLOCA PCT 2'F-35'F 1749 F 1716 F
~'f