 Issue dateTitleTopic
ML20043B58624 May 1990Special Rept 90-004:on 900427,fire Barriers Nonfunctional for More than 7 Days.Caused by Planned Const Activities to Modify Primary Access Point.Fire Barriers Expected to Be Restored by 900701Fire Barrier
ML20043B60524 May 1990Special Rept 90-005:on 900429,containment Bldg Personnel Hatch Opened to Support Maint Activities for More than 7 Days.Containment Personnel Hatch Closed & Declared Functional on 900509Fire Barrier
ML20042F7561 May 1990Special Rept 90-003:on 900326,yard Fire Hydrant Inoperable for More than 14 Days in Order to Support Mods to Primary Access Point.Hydrant Returned to Svc on 900425
ML20006C5171 February 1990Special Rept 90-002:on 900125,water Level in Both Fire Protection Water Storage Tanks Less than Tech Spec Limits. Pipe Will Be Evaluated to Determine Cause of Failure & Affected Section Will Be Replaced
ML20006D25331 January 1990Special Rept 90-001:on 900111,Train Reactor Vessel a Level Indicating Sys Inoperable for More than 7 Days.Replacement of Train a RVLIS Scheduled to Begin During Next Refueling Outage in Fall of 1990
ML20006B98126 January 1990Ro:On 900125,fire Protection Water Storage Tanks Decreased Below Required Min Level Caused by Crack in Fire Protection Sys Yard.Crack Was Isolated & Level Restored to Above Min within Two Hours
ML19332C82821 November 1989Special Rept 89-005:on 891030,fire Barrier Penetration Open for More than 7 Days During Ninth Refueling Outage.Cause Not Stated.Continuous Fire Watch,Operability of Fire Detectors & Hourly Watch Patrol EstablishedFire Barrier
Continuous fire watch
Hourly Fire Watch
ML19327B9731 November 1989Special Rept 89-003:on 891013,fire Barrier Penetration Open for More than 7 Days During Ninth Refueling Outage.Hatches Opened to Support Outage Activities.Containment Personnel & Equipment Hatches Closed on 891014Fire Barrier
Continuous fire watch
Hourly Fire Watch
ML19327B9701 November 1989Special Rept 89-004:during Refueling Outage,Six Steam Generator Tubes Exceeded Pluggable Limit Based on Eddy Current Testing Results.Total of 24 Steam Generator Tubes Plugged
ML20050C10812 March 1982Ro:During Low Power Physics Testing for Cycle 4,moderator Temp Coefficient in Hot Zero Power,Beginning of Cycle Condition Measured Greater than Required by Tech Spec. Control Rod Withdrawal Limits Established
ML20050C12212 March 1982Ro:On 820228,safety Injection & Reactor Trip Occurred During Attempt to Synchronize Unit.Also on 820228,boron Concentration in Boron Injecton Tank Fell Below Min Required Level
ML20050B00910 March 1982Ro:On 820310,inadvertent Actuation of Fire Protection Deluge Sys on Cooling Tower 1A Caused Levels in Fire Protection Tanks a & B to Fall Approx 85,000 Gallons.Caused by Maint Activities.Pressure Decrease Investigated
ML20041A5198 February 1982Ro:On 820101,fire Door 418 Declared Inoperable Due to Improper Closure.Door Repaired & Returned to Svc on 820114. Delay Due to Hardware Procurement
ML20039E07328 December 1981Ro:On 811226,containment Spray Additive Tank Isolation valve,V024,found in Closed Position Rendering Containment Spray Additive Tank Inoperable.Valve Opened & Locked. Investigation Underway.Further Details Forthcoming
ML20039D30518 December 1981Ro:On 811116,seal on Fire Barrier Cable Penetration 34-100-06 Damaged & Declared Inoperable.Cause Not Stated. Training in Administrative Requirements Will Be Given for Implementing Design Changes Re Breach of Fire BarrierFire Barrier
ML20039D30917 December 1981Ro:On 811211,analysis Performed Indicating Fecal Coliform Value Too High to Calculate for Sewage Treatment Plant 2A.Caused by Chlorination Sys Malfunctioning Causing Chlorine Residual to Decrease
ML20009F61724 June 1981Ro:On 810518,during Plant Fire Marshall Insp,Fire Barrier Penetration in Cable Spreading Room Was Declared Inoperable, Due to Improper Sealing.Penetration Sealed,Inspected & Returned to Svc on 810613Fire Barrier
ML20009F84011 June 1981Ro:On 810610,as Result of Inadvertent Actuation of Fire Protection Deluge Sys on Cooling Tower 2B,levels in Tanks a & B Fell to Approx 235,000 Gallons.Clipper Valve Opened & Deluge Sys Actuated
ML20009G14418 May 1981Ro:On 810515,fire Main in Low Voltage Switchyard Ruptured, Causing Protection Tanks a & B Levels to Fall Below Tech Specs.Cause of Initial Rupture Not Stated.Tank Returned to Acceptable Levels.Followup Will Be Provided
ML20003F68915 April 1981Ro:On 810321,cable Spreading Room Sprinkler Sys Was Declared Inoperable.Caused by Spurious Actuation of Sprinkler Sys. Smoke Detector Reset Switch Was Modified & Sys Returned to Svc
ML19341B28012 January 1981Ro:On 801227,one Tube in Steam Generator 1C Satisfactorily Plugged.Defective Tube Located by Pressurizing Secondary Side & Performing Visual Insp for Leaks.Tube Plugging Reported Per Tech Spec 4.4.5.5.a
ML19257C59221 January 1980Ro:On 791024,w/plant in Mode 4,train a Safety Injection Block Light Turned Off,Actuating Injection on Train A.Cause Undetermined.P/O Universal Card A416 Replaced.Logic Test Performed on Train a & Train Returned to Svc on 791025
ML19290B7408 November 1979RO-79-055-01P:Westinghouse Notified Util of Potential for P-4 Permissive Failures to Remain Unidentified During Performance of Surveillance Tests.Details Will Be Provided in Followup Rept
ML19210F0267 November 1979RO-79-054-01P:on 791107,cooling Tower B Fire Resulted in Reduction of Fire Protection Tank Levels.Tanks a & B Fell to 120,000 Gallons.Tank Levels Will Be Returned to Min Acceptable Levels on 791107
ML19250A4769 October 1979Nonroutine Environ Operating Rept:On 791008,inadvertent Gaseous Release Occurred During Maint on Waste Gas Decay Tank 8 Inlet Isolation Valve Bonnet.Caused by Faulty Instructions of Work Request & Inadequate Communication
ML19209D1378 October 1979Ro:On 791008,inadvertent Gas Release Occurred While Performing Maint on Waste Gas Decay Tank Inlet Isolation Valve Bonnet.Bldg Was Evacuated.Radiation Tests on Personnel Negative
ML19253B35520 September 1979Ro:On 790814,carbon Dioxide Fire Protection Sys for Diesel Generator Bldg Declared Inoperable.Caused by Malfunction of Carbon Dioxide Timers Associated W/Rooms 1-2A & 2R.Fire Watch Conducted Until Timer Replaced & Sys OperableFire Watch
ML19208B20128 August 1979RO-79-041-01P:on 790825,Westinghouse Submitted Rept Re Heat Sink Shorting on Certain 7300 Series Printed Circuit Cards. Seismic Vibration Could Cause Card Guide Rubbing of Heat Sinks & Calibr Shift