 Issue dateTitleTopic
ML20115H01117 July 1996Special Rept:On 960703,main Stack Wide Range Gas Radiation Monitor Sys Removed from Svc for Planned Mod.Sys Expected to Be Returned to Svc by 960830 After Mod Work Completed
ML20115H76817 July 1996Special Rept:On 960603,Unit 2 Vent Stack Wide Range Gas Radiation Monitor Sys Removed from Svc for Planned Mod.Sys Subsequently Returned to Svc on 960701.Mod Replaced
ML20111B47510 May 1996Special Rept:On 960422,vent Stack Wide Range Gas Radiation Monitor Sys Was Removed from Svc for Planned Mod.Field Survey Teams Would Be Dispatched to Monitor Radioactive Effluents as Defined in Plant Emergency Plan
ML20092M17522 September 1995Special Rept:On 950726,valid Failure of E-3 EDG Occurred Due to Dead Spot on Potentiometer Which Affected E-3 EDG Controller Output signal.E-3 EDG Returned to Operable Status Following Motor Operated Potentiometer Replacement
ML20087H25114 August 1995Special Rept:On 950726,non-valid Failure of E-3 EDG Occurred Due to Dead Spot on E-3 EDG Motor Operated Potentiometer (MOP).E-1 & E-3 EDG Mops Will Be Replaced W/New Type Mop During Future Mod Outages
ML20086R51725 July 1995Special Rept:On 950630,determined That Number 12 Cylinder on E-1 D/G Had Lower than Normal Operating Temps During Surveillance Test.Caused by Failure of Fuel Oil Injector Pump.Injector Pump Replaced & Satisfactorily Tested
ML20078C17024 October 1994Special Rept:On 940924,valid Failure of E-2 EDG Occurred. Caused by Problem w/4 Kv Breaker.Breaker Incorporated Into Preventive Maint Program to Replace Grease
ML20071Q5772 August 1994Special Rept:On 940706,valid Failure of E-4 Emergency Diesel Generator Occurred.Caused by Solenoid Valve Spuriously Sticking.Valves Replaced
ML20064C30128 February 1994Special Rept:On 940211,non Valid Failure of EDG E-4 Occurred When Voltage Shutdown Button Inadvertently Bumped.Maint Insp Initiated to Determine If Generator Damage May Have Occurred Due to Event.Remaining EDGs Were Operable
ML20059A82722 October 1993Special Rept:On 931012,valid Failure of EDG E-2 Occurred During Routine Monthly Test.Edg E-2 Declared Inoperable Due to High Fuel Oil Differential Pressure Condition.Edg E-2 Fuel Oil Filters Replaced
ML20056G87027 August 1993Special Rept:On 930803,discovered That Cylinder on 2-EDG Lower than Normal Operating Temps.Caused by Fuel Pin on Cylinder Injector Pump Not Fully Engaged
ML20079L62930 October 1991Special Rept:On 910916 & 23,cable Spreading & Computer Room CO2 Fire Protection Sys Out for Svc for More than 14 Days. Caused by Need to Provide for Worker Safety During Mod Work. Fire Detectors Verified Operable & Firewatch Stationed
ML20077P97015 August 1991Special Rept:On 910714,diesel Driven Fire Pump Out of Svc for More than Seven Days Due to Annual Preventative Maint Activities.Preventative Maint Completed & Pump Returned to Svc.Operability Testing Completed Satisfactorily on 910723
ML20064A46527 August 1990Special Rept:On 900802,diesel-driven Fire Pump Declared Inoperable During Testing Due to Engine Overheating.Caused by Silt & Marine Biotic Life Plugging Y Strainer in Cooling Line.Strainer Cleaned & Retested
ML20059B89921 August 1990Special Rept:On 900802,diesel Driven Fire Pump Declared Inoperable During Testing Due to Engine Overheating.Diesel Generator E-2 Returned to Operable Status & motor-driven Fire Pump Declared Operable on 900807
ML20058N6658 August 1990Special Rept:On 900802 & 07,diesel Driven & Motor Driven Fire Pumps,Respectively,Declared Administratively Out of Svc.Caused by Engine Overheating & Diesel Generator (DG) E-2 Out of Svc.Local Fire Depts Notified & DG E-2 Repaired
ML20245H44610 August 1989Ro:On 890710,diesel Driven Fire Pump Out of Svc for More than 7 Days.Caused by Disconnected Coolant Hose from Engine Block During Test,Draining Coolant from Engine & Heat Exchanger.Insp & Repair of Engine Performed
ML20245J5571 May 1989Ro:On 890331,motor Driven Fire Pump Out of Svc in Excess of 7 Days.Caused by Removal of Pump from Svc on 890324 to Allow Implementation of Electrical Mods.Diesel Driven Fire Pump Verified Operable & Tested Every 72 H
ML20245B33914 April 1989Special Rept:On 890303,seismic Monitoring Instruments Inoperable for More than 30 Days.Caused by Triaxial Accelerometer Cables Picking Up Electrical Noise Which Caused Spurious Alarms.Noise Filters Will Be Installed
ML20195E5013 November 1988Special Rept:On 881020,diesel Driven Fire Pump Failed to Start Automatically During Surveillance Test.Caused by Inadequate Test.Diesel Driven Fire Pump & auto-start Feature Tested & Rev of Fire Pumps Surveillance Tests in Process
ML20205H25621 October 1988Ro:On 881020,diesel Driven Fire Pump Failed to Start Automatically During Performance of Surveillance Test.Cause Under Investigation.Diesel Driven Fire Pump Subsequently Tested Successfully & Returned to Svc
ML20154A7262 September 1988Special Rept:On 880726,motor-driven Fire Pump Out of Svc for More than 7 Days.Caused by Action Taken to Allow Cleaning & Insp of of E-42 4 Kv bus.Motor-driven Fire Pump Restored to Operable Status on 880821
ML20154A9611 September 1988Special Rept:On 880822,discharge Pressure Lost While Motor Driven Fire Pump in Operation.Caused by Crack That Formed in Column Pipe Flange Area Where It Bolts to Pump.Motor Driven Pump Removed from Pump Structure,Disassembled & Inspected
ML20195B85015 June 1988Special Rept:On 870215,packing Leak from RCIC Outboard Isolation Valve Reported to Operating Shift.Caused by Steam Leak.New Grease Replaced.On 870915,degradation to Motor Operator & Field Wiring Discovered.Components ReplacedPacking leak
Stroke time
ML20154P35927 May 1988Special Rept:On 880415,carbon Dioxide Fire Suppression Sys Taken Out of Svc for More than 14 Days.Caused by Continuous Fire Watch Required in Cable Spreading Room During Repair of Hole in Floor.Hole Repaired & Subj Sys Returned to SvcFire Barrier
Continuous fire watch
Fire Watch
ML20153B31016 March 1988Special Rept:On 880302,E-224 440-volt Emergency Load Ctr Supply Breaker Tripped Open,Removing Power Supply for Motor Driven Fire Pump.Caused by Failure of Undervoltage Relay on E-22 Bus.Failed Relay Replaced
ML20153B46816 March 1988Revised Special Rept Re Diesel Driven Fire Pump out-of-svc for More than Tech Spec Limit of 7 Days.On 871111,diesel Driven Fire Pump Declared Inoperable.Probably Caused by Battery Failures.Surveillance Procedure Revised
ML20196G5527 March 1988Ro:On 880302 & 05,motor Driven Fire Pumps Declared Inoperable.Caused by Level in Storage Tank Dropped Due to Oil Being Transferred from Storage to Day Tank.Diesel Fuel Added Storage Tank to Bring Level Above 300 Gallon Limit
ML20147G1533 March 1988Ro:On 880302,both Fire Pumps Became Inoperable When Breaker E-224 for Motor Driven Fire Pump Tripped.Diesel Driven Fire Pump Taken Out of Svc for Maint on 880301.Caused by Failure of Bus E-22 Undervoltage Relay.Temporary Jumpers Installed
ML20147C20811 January 1988Special Rept:On 871216,planned Release of Liquid Radwaste from Laundry Drain Tank B Made W/O Being Treated as Described in Limiting Condition of Operation 3.8.B.4.Caused by Procedural Deficiency.Procedure Revised
ML20238C50721 December 1987Special Rept:On 871111,diesel-driven Fire Pump Failed Surveillance Test & Declared Inoperable.Cause Unknown.Four Sets of Cells for Two Batteries Replaced & Charged W/Portable Charger.Surveillance Test Procedure Revised
ML20236K9113 August 1987Ro:On 870731,motor Driven Fire Pump Automatically Started on Decreasing Header Pressure at 140 Psig.Caused by Personnel Digging in Yard Directly Behind Radwaste Bldg.Affected Portion of Fire Header Isolated for Repair of Leak
ML20214W7695 June 1987Special Rept:On 870428,bus E22 Deenergized to Perform Series of outage-related Mods,Causing Motor Driven Fire Pump to Be out-of-svc for More than 7 Days,In Violation of Tech Specs. Motor Driven Fire Pump Restored to Svc on 870515
ML20214U0344 June 1987Special Rept:During Update of Safe Shutdown Data Base, Conditions Re Unencapsulated Cables in Fire Areas Identified as Reportable Per Confirmatory Action Ltr 86-07 & App R. Caused by Exclusion from Previous Analysis.Fire Watch BegunSafe Shutdown
Fire Watch
05000000/LER-1986-009, Ro:On 860312,discovered That LER 2-86-04 & LER 86-009 Not Submitted to Nrc.Caused by Misplaced Repts.Repts Telecopied to Nrc.Procedure for Distribution of Repts Revised14 April 1986Ro:On 860312,discovered That LER 2-86-04 & LER 86-009 Not Submitted to Nrc.Caused by Misplaced Repts.Repts Telecopied to Nrc.Procedure for Distribution of Repts Revised
ML20199F44027 March 1986Special Rept:On 860216,during Cold Shutdown,Condensate Storage Tank (CST) Filled & Overflowed Into CST Moat & Outside Moat.Caused by Blown Fuse Resulting in Removal of Power from Hotwell Level Controllers.Fuse Mods Considered
ML20093F19521 September 1984RO MM-3-03:on 840823,routine Surveillance Testing Indicated Three Moisture Sensors in Recirculation Sys Moisture Monitoring Sys Functioning Improperly.Cause Not Determined. Hourly Monitoring Being Performed
ML20096F49014 August 1984RO-MM-3-02:on 840715,surveillance Test Revealed Malfunctioning of Moisture Sensors in Recirculation Sys Moisture Monitoring Sys.Cause Unknown.Hourly Monitoring of Drywell Sump Collection Initiated Until Next Outage
ML20094F44523 July 1984RO MM-3-01:on 840622 & 25,moisture Sensors in Recirculation Sys Moisture Monitoring Sys Functioned Improperly.Cause Unknown.Drywell Sump Collection Sys Monitored Hourly Until Next Outage
ML20083Q02323 March 1984Ro:On 840224,during Verification of Moisture Monitoring Sys,Point 7 Failed.Cause Will Be Determined During Next Outage W/Drywell Deinerted.Drywell Sump Collection Sys Will Be Monitored Hourly
ML20083P96312 March 1984Ro:On 840209,CO2 Fire Protection Sys,Serving Cable Spreading Room & Computer Room,Declared Inoperable.Caused by Ground in One of Two Cables from Smoke Detector Control Panel.Cables Replaced & Sys Available for SvcContinuous fire watch
ML20083P8205 March 1984Ro:On 840125,moisture Sensor in Recirculation Sys Moisture Monitoring Sys Functioned Improperly & Sys Declared Inoperable.Caused by Failed Techmark Limited Moisture Sensor Circuit Card.Sensor Replaced
ML20080A77316 January 1984Ro:On 831128,from 830830-1128,seismic Monitoring Sys Inoperable.Caused by Personnel Oversight.Startup check-off List Modified to Require Maint Request
ML20069L31711 April 1983Corrected RO 3-83-11/1P:on 830407,full-in Position Signal Jumpered Into Probe Buffer Cards.Control Rods Could Have Been Withdrawn W/O Initiating Single Control Rod Interlock. Caused by Personnel Error.Jumpers Removed
ML20079L26815 February 1983RO 3-83-08/1P:on 830214,three of Eight MSIVs Failed to Pass Tech Spec Limit of 11.5 Scfh & Containment Isolation Valve Mo 2-74 Failed Leak Rate Test.Caused by Abnormal Wear of Valve Internals.Valves to Be Inspected & Repaired
ML20066A58128 October 1982RO 2-82-36/1P:on 821024,71J Safety Relief Valve Opened When Pressure Reached 832 Psig.Cause Unknown.Valve to Be Sent to Vendor.Two Vacuum Breakers Replaced.Fatigue Analysis Determined Downstream Piping Not Overstressed
ML20066A93925 October 1982Ro:Response Spectrum Analyzer Component of Seismic Monitoring Sys Intermittently Inoperable Since 820909.Caused by Malfunctioning Power Control Card.Card Will Be Replaced. Component to Be Returned to Svc by 821130
ML20058B71014 July 1982Ro:On 820619,during Scheduled Loss of Power Test on Unit 2, Inadvertent Startup of ECCS on Unit 3 Initiated While at Full Power.Caused by Defective Elma Dc Power Supply to 24-volt Dc Logic Circuit
ML20055B51813 July 1982RO Advising That Triaxial Accelerometer Devices in Reactor Core Isolation Cooling Sys Pump Room Inoperable for More than 30 Days.Replacement Detector to Be Installed by 820831
ML20126L14420 May 1981RO 2-81-32/1P:on 810520,w/units in Shutdown Condition, re-evaluation of Concrete Block Walls Identified Four Walls Unstable Under Effects of Tornado Depressurization & Cardox Injection.Caused by Const or Design Error