Text
f
~
~
jj,,,,i,,,,,,,,_,,i,,
=y PECO NUCLEAR reco cae<av comneev 1848 t.ay Road
)
' A Unir or. PECO Entacy yyQ4MM May 10, 1996 Docket Nos.
50-278 License Nos.
DPR-56 Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555
SUBJECT:
PEACH BOTTOM ATOMIC POWER STATION UNIT 3 SPECIAL REPORT-VENT STACK WIDE RANGE GAS RADIATION MONITOR SYSTEM OUT OF SERVICE GREATER THAN SEVEN i
DAYS
REFERENCES:
PEACH BOTTOM ATOMIC POWER STATION TECHNICAL REQUIREMENTS MANUAL 3.6.D.1
Dear Sir:
1 Description of Occurrence On 4/22/96, the Unit 3 Vent Stack Wide Range Gas Radiation Monitor System was removed from service for a planned modification.
The Peach Bottom Technical Requirements Manual requires a special report submission when this system is inoperable greater than seven days. The system is expected to be returned to service by 5/25/96.
Corrective Actions Taken The Vent Stack Wide Range Gas Radiation Monitor System is used for post-accident monitoring. In the remote possibility that an accident was to occur during this period of inoperability, field survey teams would be dispatched to monitor radioactive effluents as defined in the Peach Bottom Emergency Plan.
Plan for Restorina Eauipment to an Operable Status The system _will be returned to service after modification work is complete. The work is expected to be complete by 5/25/96.
4 i
'9605140451 960510 73 0
- PDR ADOCK 05000278-i S
PDR n.
U. S. Nuclear Regulatory Commission Page2 If you have any questions or require additionalinformation, please do not hes! tate to contact us.
Sincerely, Garrett D. Edwards Plant Manager i
GDE/
JHG:jhg cc:
B.
Gorman, Public Service Electric & Gas R. R. Janati, Commonwealth of Pennsylvania T. T. Martin, US NRC, Administrator, Region i R.1. McLean, State of Maryland W. L. Schmidt, US NRC, Senior Resident inspector A. F. Kirby ill, DelMarVa Power H. C. Schwemm, VP - Atlantic Electric l
CCN#96-14044
-