PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE--PNO-III-87-44A Date March 30, 1987 .

1 This preliminary notification constitutes EARLY notice of events of POSSIBLE safety or public interest significance. The information is as initially received without verification or evaluation, and is basically all that is known by the Region III staff on this date.

Facility: Consumers Power Company Licensee Emergency Classification:

Palisades Nuclear Power Plant Notification of an Unusual Event Covert, MI 49043 Alert Site Area Emergency Docket: 50-255 General Emergency XX Not Applicable

Subject:

CAL ISSUED ALLOWING RESTART OF PALISADES (UPDATE)

After an attempted critical approach on March 27, 1987, the Palisades plant was taken back to cold shutdown to replace a nuclear instrument detector which did not indicate properly.

Tha Palisades plant had been shut down since a trip on May 19, 1986, during which several equipment malfunctions were noted. As a result of the concerns raised by the NRC, the licensee comitted to go to cold shutdown and investigate a variety of problems and a Confirmatory Action Letter (CAL) was issued on May 21, 1986. A ten month outage ensued during which the licensee identified and corrected a number of design bases and material condition problems. On March 26, 1987, the licensee notified the Regional Administrator that all commitments had been met and requested permission to restart. Authorization was granted on March 27, 1987, to restart but replacement of a failed nuclear instrument required the plant to return to cold shutdown. The licensee estimates completion of the work by April 1, 1987.

The State of Michigan will be notified.

This information is current as of 10:30 a.m. (CST), March 30, 1987, CONTACT:

h Y B. Burge'ss W. Guldemond l

FTS 388-5689 FTS 388-5574 DISTRIBUTION:

H. St. ED0 NRR E/W Willste Mail: ADM:DMB Chairman Zech PA IE NMSS D0T:Trans only Comm. Roberts ELD OIA RES Comm. Asselstine AE0D NRC Ops Ctr W @

Comm. Bernthal Comm. Carr SP WO\ Regional Offices ACRS SECY INP0 W O h NSAC @ 07 CA RIII Resident Qf,fice PDR Licensee: M* A% (Corp. Office - Reactor Lic. Only)

Region III B704030200 870330 ev. oveder N

-1 87- Y PDR 153l