PNO-III-85-060, on 850712,facility Shut Down for Maint on RHR Sys Train a Shutdown Cooling Injection Valve & Train B Suppression Pool Spray Valve.Valves Failed Local Leak Rate Testing.Outage Expected to Last Until 850722

From kanterella
Jump to navigation Jump to search
PNO-III-85-060:on 850712,facility Shut Down for Maint on RHR Sys Train a Shutdown Cooling Injection Valve & Train B Suppression Pool Spray Valve.Valves Failed Local Leak Rate Testing.Outage Expected to Last Until 850722
ML20128K271
Person / Time
Site: LaSalle Constellation icon.png
Issue date: 07/16/1985
From: Chrissotimos N, Landsman R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
References
PNO-III-85-060, PNO-III-85-60, NUDOCS 8507240078
Download: ML20128K271 (1)


-

PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE--PNO-III-8 5-60 Date July 16, 1985 b

Thispreliminaryn;tificationctnstitutesEARLYnsticeofeventsofPOSSIBLEsafetyor*),g1 public interest significance. The information is as initially received without veri-

' fication or evaluation, and is basically all that is known by the staff on this date.

Facility: Commonwealth Edison Co. Licensee Emergency Classification:

LaSalle Unit 1 Notification of an Unusual Event Marseilles, IL 61341 Alert Site Area Emergency Docket No: 50- 373 General Emergency xx Not Applicable

Subject:

SHUTDOWN FOR VALVE MAINTENANCE Unit I was shut down on July 12, 1985, for maintenance on two containment valves which had failed local leak rate testing. The two valves are the suppression pool spray valve from the "B" train of the Residual Heat Removal (RHR) system and the shutdown cooling injection valve in the "A" train of the RHR system.

The outage is expected to last until about July 22, 1985. The resident inspectors are monitoring the maintenance activities.

The State of Illinois will be notified.

This infonnation is current as of 11 a.m., July 16, 1985.

CONTACT:

kR. Landsman W%\

N. Chris otimos FTS 388-5587 FTS 388-5716 8507240078 850716 fNO-I 85-060 PDR DISTRIBUTION: