Text
- _ _ _ _ --
[
NERMONT YANKEE NdciEAR. POWER CORPORATION p
BVY 89-83 Ferry Road, Brattleboro, VT 05301-7002 ENGINEERING OFFICE d
580 MAIN STREET BoLTON, t/A 01740 1508)779-6711 September 1, 1989 U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Attention:
Document Control Desk
References:
a)
License No. DPR-28 (Docket No. 50-271) b)
Letter, VYNPC to USNRC, FVY 88-16, dated 3/1/88
Dear Sir:
Subject:
~ Vermont. Yankee Containment Safety Initiatives Status Update Vermont Yankee provided a status report (Reference b)] with regard to implementation of an enhanced containment spray capability, end ongoing investi-gation into the need for a containment overpressure protection (COP) capability associated with postulated severe accident scenarios.
l Since our March 1, 1988 letter, Vermont Yankee has completed the installa-tion of an enhanced containment spray capability. The enhanced containment spray capability was shown to have benefits for beyond design basis events without adversely affecting plant capabilities with regard to-design basis events. NRC and industry studies have shown that for'certain scenarios, the enhanced containment spray capability provides significant benefit for plant severe accident (beyond design basis) mitigation.
In addition to enhanced con-tainment spray capability, this modification enhances the capability to inject water to the reactor core.
Our letter also indicated that efforts were continuing in order to assess the value of venting as a means to provide containment overpressure protection.
Based upon our continuing evaluation of the investigations by the NRC, industry, and Vermont Yankee, we have concluded that an enhanced COP could be of some benefit during certain severe accident events.
Providing that the overpressure protection would not reduce the overall margin of safety, is of a passive design, and is designed such that it in no way adversely affects the existing design basis, Vermont Yankee believes that such a feature could provide an overall enhancement in our ability to respond to a severe accident.
Vermont Yankee expects to establish specific design criteria such that we can install enhanced containment' overpressure protection capability by the end of the 1992 refueling outage.
8909120372 890901 PDR ADOCK 05000271 P
PDC r i
~ ',
VERMONT YANKEE NUCLEAR POWER CORPORATION
..a U.S. Nuclear Regulatory Commission September 1, 1989 Page 2 The design will consist of a hardened vent line from the wetwell vapor space to the plant stack. The basic design objective is to provide sufficient capability to prevent long-term overpressurization of the containment.
The exhaust path will have the capability to be isolated by a suitable isolation valve.
Vermont Yankee will continue to support and follow the various efforts in progress aimed at resolving severe accident issues. We feel that installation of an enhanced containment overpressure protection capability, in addition to the enhanced containment spray capability that we installed during our last l
(1989) refueling outage, demonstrates Vermont Yankee's ongoing commitment l
toward improving overall plant safety.
We will keep the NRC informed on the progress of our design and our final plans for implementation.
If you have any questions or concerns, please do not hesitate to contact us.
Very truly yours, VERMONT YANKEE NUCL EAR POWER CORPORATION gian- ---
9 Warren P.
rph Vice President and Manager of Operatio
/dm cc: USNRC Regional Administrator, Region I USNRC Resident Inspector, VYNPS USNRC Project Manager, VYNPS
_