m q
w
.,w k?
YANKEEATOMICELECTRIC CObfPANY.
- C"%l.jl7$i'l" I
L D
pb
'580 Main Street, Bolton, Massachusetts 01740-1398
.YANKEIE m.
November 30,.1989
'C
~
BVY 89-111 DCC 89-055 v
- A yU,
," United States Nuclear Regulatory Commission fDocument Control Desk 5;
.L Washington, DC 20555
References:
(a) License.No.-DPR-28 (Docket No. 50-271)
-(b) Letter, VYNPC to USNRC, BVY 89-60, dr.ted Juni 30, 1989 with Topical Reports YAEC-1693 and YAEC-1694 (c) Letter, YAEC to USNRC, BVY 89-102=and DCC 89-049, dated November 6, 1989 Subjects.
Submittal of " Application of One-Dimensional Kinet.ics to Boiling Water Reactor Transient Analysis Methods" Report i
L
Dear Sir:
In accordance with Reference (c), Yankee Atomic Electric Company submits the subject report which is a revised version of the report submittad with I
Reference (b).
In Reference (c).we modified our request for review and approval of the Vermont Yankee One-Dimensional (1-D) kinetics topical reports f.YAEC-1693 and YAEC-1694) to incorporate a generic topical review and approval._:The enclosed. minor administrative changes to this report should K'
permit'your generic' review and approval of our 1-D kinetics methods to be
-finalized.
The report, " Application of One-Dimensional Kinetics to Boiling Water Reactor Transient Analysis Methods," YAEC-1693'(enclosed with Reference (b)),
presents the methodology, verification, and just ification for. application of RETRAN-02'l-D kinetics option to the prerently approved transient analysis methods.- - The report documents the method for analyzing boiling ws '.Ar reector transients with RETRAN-02 with the 1-D kinetics option using Vertrvat 'fenkee results to verify the methods.' The minor administrative' changes to the report
-which properly identify the generic applical. ion of-the methods occur in the
~
Title Page, the Abstract (Page iv), Section 1.0 (Introduction, Page 1),
Section 2.0.(Description or Current Licensing Method,'Pages 2 and 31,
- Section 3.0~(Description of the Application of One-Dimensional Kinetics,
,Pages 7.through 9), Section 4.0 (Verification of One-Dimensional Kinetics N
. Application, Pages 15 through 21), Section 5.0 (Licensing Approach and
. Treatment of Uncertainties, Pages 36, 38, and 39),
~
Section 6.0 (Conclusions, Pages 40 and 41), and Appendix A (Determination of ACPR95 Through a Response Surface. Appe, ":h, Page A-1).
W 1
w 8912140211 g91130
\\
ADOCK 0 % [
. P.
. ~
m;.
~
c, ' " y 3
j4f+
United Statss Nuclear Regulatory Commission November 30, 1989 Page 2 I;,
t lb l;i m
The report, " Method for Generation of One-Dimensional Kinetics Data for RETRAN-02 " YAEC-1694.(also enclosed with Reference (b)), does not require-Q reviolon for generic application because it is already presented in the-terminology of a generic topical report..
We trust that this information supports our request; however, should you have any questions on this matter, please contact us.
L Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY E4/
Stephen P. Schultz Vice President
-SPS/gj t/0939u Enclosure cc: USNRC Region I Administrator USNRC Resident Inspector, VYNPS lJ USNRC Project Manager VYNPC 1
e
{
1' i
L L
1 1 -.
l-l
"