Notice of Violation from Insp on 970519-0613.Violations Noted:Inspectors Identified on 970613 That Weld Procedure Wps GT-SM/3.3-2 Pb,Rev 1,did Not Meet Requirements of QW-409.1
ML20217A261
Person / Time
Site: Point Beach  NextEra Energy icon.png
Issue date: 09/15/1997
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20217A255 List:
References
50-266-97-10, 50-301-97-10, NUDOCS 9709190110
Download: ML20217A261 (2)


Text

- - - _ .- . - _ . - - _ _ -

0 NOTICE OF VIOLATION Wisconsin Electric Power Company Docket Nos. 50 266; 50 301 Point Beach Nuclear Plant License Nos. DPR 24; DPR 27 During an NRC inspection conducted from May 19,1997, through June 13,1997, violations of NRC requirements were identified. In accordance with NUREG 1600," General Statement of Policy and Procedure for NRC Enforcement Actions," the violations are listed below:

1. 10 CFR 50, Appendix B, Critorion V," Instructions, Procedures, and Drawings," requires, in part, that activities affecting uality be prescribed by documented procedures of a type appropriate to the circumstances and shall be accomplished in accordance with these procedures.

Nuclear Procedure (NP) 5.3.1, " Condition Reporting Sysm," states, in part, that the condition report (CR) is a method to identify, evaluate if necessary, and correct an event or condition which has the potential to adversely affect operability of safety related systems or equipment including discrepancies associated with calibrations.

Contrary to the above, the inspectors identified on June 5,1997, that the licensee failed to follow NP 5.3.1. A condition report was not initiated for the G03 emergency diesel Generator (EDG) voltage monitoring relay out of-calibration condition. The relay was successfully re calibrated on May 22,1997; however, the out-of tolerance condition was not evaluated as to the relay's potential impact on past EDG operability.

This is a Severity Level IV violation (Supplement 1).

2. 10 CFR 50, Appendix B, Criterion IX, *Contrui of Special Processes," requires,in part, that measures shall oc established to assure that special processes, including welding, are controlled and accomplished by qualified personnel using qualified procedures in accordance with applicable codes, or d standards.

ASME Section IX,1995 Edition, requirement QW-409.1, as implemented by requirement OW 250, requires that "A change in the type of current or polarity, an increase in heat input, or an increase in volume of wold metal deposited per unit length of weld, (is not allowed) over that qualified."

Contrary to the above, the inspcctors identified on June 13,1997, that weld procedure WPS GT SM/3.3-2 PB, Revision 1, did not meet the requirements of QW-409.1. The weld procedure allowed welding to be pMarmed with an increase in heat input over that which had been demonstrated through Charpy impact testing of the qualification wold.

This is a Severity Level IV violation (Supplement 1).

Pursuant to the provisions of 10 CFR 2.201, Wisconsin Electric Power Company is hereby required to submit a written statement or explanation to the U.S. Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington, D.C. 20555 with a copy to the 9709190110 970915 PDR ADOCK 05000266 G PDR t a

lC i Notice of Violation 2 .

l l Roglonal Administrator, U.S. Nuclear Regulatory Commission, Region Ill,801 Warrenville Rcad, Lisle, Illinois 60532, and a copy to the NRC Resident inspector at the facility that is the subject of this Notice, within 30 days of the date of the letter transmitting this Notice of Violation (Notico). This reply should be clearly marked as a " Reply to a Notice of Violation" and should include for each violation: (1) the reason for the violation, or, if contested, the basis for disputing the violation, (2) the corrective steps that have been taken and the results achieved, (3) the corrective steps that will be taken to avoid further violations, and (4) the date when full compilance will be achieved. Your response may reference or include previous docketed correspondence,if the correspondence adequately addresses the required response. If an adequate reply is not received within the time specified in this Notice, an order or a Demand for Information may be iqued as to why the license should not be modified, suspended, or revoked, or why such other action as may be proper should not be taken. Where good cause is shown, consideration will be given to extending the response time.

Because your response will be placed in the NRC Public Document Room (PDR), to the extent possible, it should not include any personal privacy, proprietary, or safeguards information so that it can be placed in the PDR without redaction, if personal privacy or proprietary information is necessary to provide an acceptable response, then please provide a bracketed copy of your response that identifies the information that should be protected and a redacted copy of your response that deletes such information. If you request withholding of such material, you must specifically identify the portions of your response that you seek to have withheld and provide in i detall the bases for your claim of withholding (e.g., explain why the disclosure of information will create an unwarranted invasion of personal privacy or provide the information required by 10 CFR 2.790(b) to support a request for withholding confidential commercial or financial information). If safeguards information is necessary to provide an acceptable response, please provide the level of protection described in 10 CFR 73.21.

Dated at Lisle, Illinois, this 15t.h day of September 1997 4