Category:INSPECTION REPORT
MONTHYEARIR 05000213/19990021999-08-20020 August 1999 Insp Rept 50-213/99-02 on 990420-0719.No Violations Noted. Major Areas Inspected:Decommissioning Operations & Sf Safety Maint & Surveillance,Plant Support & Rediological Controls IR 05000213/19990011999-05-21021 May 1999 Insp Rept 50-213/99-01 on 980119-990419.No Violations Noted. Major Areas Inspected:Aspects of Licensee Activities in Preparation for Dismantlement & Decommissioning of Facility IR 05000213/19980061999-02-26026 February 1999 Insp Rept 50-213/98-06 on 981103-990118.Violations Noted. Major Areas Inspected:Aspects of Licensee Activities in Preparation for Dismantlement & Decommissioning of Facility. Security Program Was Also Inspected IR 05000213/19980051998-12-21021 December 1998 Insp Rept 50-213/98-05 on 980720-1102.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support ML20155F8511998-10-29029 October 1998 Insp Rept 50-213/98-04 on 980720-0911.Violations Noted. Major Areas Inspected:Aspects of Licensee Preparations, Planning & Implementation of RCS Chemical Decontamination, Operations,Engineering,Maint & Plant Support IR 05000213/19980031998-08-21021 August 1998 Insp Rept 50-213/98-03 on 980414-0803 & 13.Violations Noted. Major Areas Inspected:Operations,Maint,Sf Safety, Decommissioning Activities & Radiological Controls IR 05000213/19980011998-05-13013 May 1998 Insp Rept 50-213/98-01 on 980113-0413.Violations Noted.Major Areas Inspected:Decommissioning Support Activities,Spent Fuel Safety,Plant Support & Radiological Controls & Facility Mgt & Control IR 05000213/19980021998-05-0505 May 1998 Insp Rept 50-213/98-02 on 980316-20 & 25-27.No Violations Noted.Major Areas Inspected:Radiological Control Programs IR 05000213/19970091998-02-17017 February 1998 Insp Rept 50-213/97-09 on 971012-980112.Violations Noted. Major Areas Inspected:Decommissioning Operations & Planning & Included Aspects of Engineering,Maint & Plant Support IR 05000213/19970121998-01-15015 January 1998 Insp Rept 50-213/97-12 on 970812-13 & 1006-09.No Violations Noted.Major Areas Inspected:Status of Rp&C Facilities & Equipment ML20198Q9091998-01-14014 January 1998 Insp Rept 50-213/97-10 on 971008-1128.No Violations Noted. Major Areas Inspected:Plant Support IR 05000213/19970111997-12-29029 December 1997 Insp Rept 50-213/97-11 on 971006-09 & 1103-07.No Violations Noted.Major Areas Inspected:Programs for Radioactive Liquid Control IR 05000213/19970051997-11-26026 November 1997 Insp Rept 50-213/97-05 on 970708-1006.No Violations Noted. Major Areas Inspected:Plant Operations,Maint Engineering & Plant Support ML20199D4621997-11-0707 November 1997 Corrected Pages for Insp Rept 50-213/97-03 on 970408-0707 & 0805 ML20199D4881997-11-0707 November 1997 Corrected Page for Insp Rept 50-213/97-07 on 970715-30 ML20198N2821997-10-29029 October 1997 Insp Rept 50-213/97-08 on 970703,0811-0919.Violations Noted. Major Areas Inspected:Applied Radiological Controls Program, Contamination Control Program & Training of Personnel Relative to 49CFR172,subpart H IR 05000213/19970031997-10-0909 October 1997 Insp Rept 50-213/97-03 on 970408-0707 & 0805.Violations Noted.Major Areas Inspected:Operations,Engineering,Maint & Plant Support IR 05000213/19970071997-08-18018 August 1997 Insp Rept 50-213/97-07 on 970715-30.No Violations Noted. Major Areas Inspected:Plant Support Area IR 05000213/19970061997-08-12012 August 1997 Insp Rept 50-213/97-06 on 970616-0718.Violations Noted. Major Areas Inspected:Radiological Controls Program at Cyap Station,Haddam,Ct ML20149D6211997-06-13013 June 1997 Mgt Meeting Rept 50-213/97-03 on 970528.Areas Discussed: Actions in Response to Findings Detailed in NRC Insp Repts 50-213/96-12.96-201 & 97-01.Deficiencies Involved Implementation of Radiation Protection Program IR 05000213/19970041997-06-0303 June 1997 Physical Security Insp Rept 50-213/97-04 on 970505-08.No Violations Noted.Major Areas Inspected:Previously Identified Items,Mgt Control,Pa Detection Aids,Alarm Stations & Communication,Testing,Maint & Compensatory Measures ML20141F8301997-05-0808 May 1997 Insp Rept 50-213/97-01 on 970106-0407.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000213/19970021997-03-21021 March 1997 Insp Rept 50-213/97-02 on 970207-07 & 0224-26.Violation Noted.Major Area Inspected:Programs for Radioactive Liquid & Gaseous Effluent Control,Including Organization & Effectiveness of Program Implementation ML20136B4471997-02-25025 February 1997 Summary of Meeting Re Insp 50-213/96-12 on 970205 in King of Prussia,Pa to Discuss Findings Detailed in Insp Rept on 961102.Radiation Program Was Deficient in Several Areas That Resulted in Potential Exposure to Radiation ML20138J6751997-02-0404 February 1997 Insp Rept 50-213/96-13 on 961116-970105.Violations Noted. Major Areas Inspected:Plant Operations,Maintenance, Engineering & Plant Support ML20133A5031996-12-24024 December 1996 Insp Rept 50-213/96-11 on 960921-1115.Violations Noted. Major Areas Inspected:Plant Operations,Maint,Engineering & Plant Support ML20132G6211996-12-19019 December 1996 Insp Rept 50-213/96-12 on 961102-27.Apparent Violations Being Considered for Escalated Enforcement Action.Major Areas Inspected:Review of Airborne Radioactivity Event That Occurred on 961102 IR 05000213/19960101996-11-0505 November 1996 Insp Rept 50-213/96-10 on 960811-0920.No Violations Noted. Major Areas Inspected:Plant Operations,Maint,Engineering & Plant Support IR 05000213/19960801996-10-30030 October 1996 Insp Rept 50-213/96-80 on 960903-1002.Violation Noted. Major Areas Inspected:Operations,Maint,Engineering & Mgt Oversight & Controls ML20129F4701996-10-23023 October 1996 Insp Rept 50/213-96-07 on 960813-16.No Violations Noted. Major Areas Inspected:Licensee Performance During Biennial Emergency Preparedness Exercise,Emergency Facility Staffing, Procedure Emplementation & Effectiveness of Mitigation IR 05000213/19940011994-01-24024 January 1994 Insp Rept 50-213/94-01 on 940110-14.No Violations Noted. Major Areas Inspected:Projected Dose Calculation Capability from Radioactive Liquid & Gaseous Effluent Releases IR 05000213/19930211993-12-30030 December 1993 Insp Rept 50-213/93-21 on 931107-1211.Violations Noted. Major Areas Inspected:Plant Operations,Maintenance, Engineering & Technical Support & Plant Support Activities IR 05000213/19930231993-12-17017 December 1993 Insp Repts 50-213/93-23,50-245/93-30,50-336/93-25 & 50-423/93-27 on Stated Date.Violation Noted.Major Areas Inspected:Ffd Program,Policies & Procedures,Ffd Organization & Mgt Control,Training,Chemical Testing & FFD Audit IR 05000213/19930191993-11-23023 November 1993 Insp Rept 50-213/93-19 on 931003-1106.No Violations Noted. Major Areas Inspected:Plant Operations,Maintenance, Engineering & Technical Support & Plant Support Activities IR 05000213/19930161993-11-0404 November 1993 Insp Rept 50-213/93-16 on 930829-1002.No Violations Noted. Major Areas Inspected:Plant Operations,Maintenance, Engineering & Technical Support & Plant Support Activities IR 05000213/19930181993-10-0707 October 1993 Insp Rept 50-213/93-18 on 930927-30.No Safety Concerns or Violations Noted.Major Areas Inspected:Remp,Including Mgt Controls,Qa Audits,Meteorological Monitoring Program & QC Program for Analytical Measurements IR 05000213/19930151993-10-0101 October 1993 Insp Rept 50-213/93-15 on Stated Dates.No Violations Noted.Major Areas Inspected:Generic Ltr 89-10 Program & Related Activities ML20057E6661993-09-29029 September 1993 Insp Rept 50-213/93-16 on 930725-0828.No Violations Noted. Major Areas Inspected:Plant Operations,Maint,Engineering & Technical Support,Plant Support Activities,Outage Assessment & Emergency Planning Drill IR 05000213/19930121993-08-18018 August 1993 Safety Insp Rept 50-213/93-12 on 930620-0724.Violations Noted.Major Areas Inspected:Plant Operations,Outage Activities,Event Response,Maint,Engineering & Technical Support & Plant Support Activities IR 05000213/19920231993-02-0101 February 1993 Insp Rept 50-213/92-23 on 921214-18.Violations Noted.Major Areas Inspected:Ep Program Changes,Emergency Facilities, Equipment,Instrumentation & Supplies,Ep Organization & Management Control,Training & Independent Reviews/Audits IR 05000213/19920221993-01-21021 January 1993 Insp Rept 50-213/92-22 on 921116-20.Violations Noted.Major Areas Inspected:Corrective Actions of Previously Identified Insp Items IR 05000213/19920211993-01-15015 January 1993 Insp Rept 50-213/92-21 on 921115-1212.No Violations Noted. Major Areas Inspected:Plant Operations,Radiological Controls,Maint,Lers & Periodic Repts & Manual Operator Actions During Postulated Station Blackout IR 05000213/19920811993-01-0808 January 1993 Insp Rept 50-213/92-81 on 921005-09 & 29,1112,1210 & 930105 in Region I Ofc.Major Areas Inspected:Licensee Generic Ltr 89-10 Program,Including Scope & Administration of Program, Design Basis Reviews & MOV Training IR 05000213/19920241992-12-30030 December 1992 Insp Rept 50-213/92-24 on 921130-1204.No Violations Noted. Major Areas Inspected:Function of Engineering & Technical Support Reviewed to Evaluate Staffing of Engineering Dept IR 05000213/19920251992-12-22022 December 1992 Insp Rept 50-213/92-25 on 921214-17.No Violations Noted. Major Areas Inspected:Mgt Organization,Training & Assurance of Quality IR 05000213/19920201992-12-15015 December 1992 Insp Rept 50-213/92-20 on 921005-1114.No Violations Noted. Major Areas Inspected:Plant Operations,Radiological Controls,Maint,Surveillance,Licensee self-assessment & Periodic Repts IR 05000213/19900831990-11-0505 November 1990 Insp Repts 50-213/90-83,50-245/90-82,50-336/90-82 & 50-423/90-83 on 900924-28.No Violations Noted.Major Areas Inspected:Licensee Timeliness for Reporting/Operability Determinations IR 05000213/19900821990-10-23023 October 1990 Insp Repts 50-213/90-82,50-245/90-81,50-336/90-81 & 50-423/90-82,on 901001-12.No Violations Noted.Major Areas Inspected:Licensee Occupational Radiation Protection Program Activities During Unit 1 Refueling Outage IR 05000213/19900131990-10-19019 October 1990 Safety Insp Rept 50-213/90-13 on 900801-0911.Good Radiological Controls Performance Noted.Major Areas Inspected:Plant Startup Following 1989/1990 Refueling Outage,Reactor Trips on 900813 & 0903 & Safeguards Problems IR 05000213/19900181990-10-10010 October 1990 Insp Rept 50-213/90-18 on 900926.No Violations Noted 1999-08-20
[Table view] Category:NRC-GENERATED
MONTHYEARIR 05000213/19990021999-08-20020 August 1999 Insp Rept 50-213/99-02 on 990420-0719.No Violations Noted. Major Areas Inspected:Decommissioning Operations & Sf Safety Maint & Surveillance,Plant Support & Rediological Controls IR 05000213/19990011999-05-21021 May 1999 Insp Rept 50-213/99-01 on 980119-990419.No Violations Noted. Major Areas Inspected:Aspects of Licensee Activities in Preparation for Dismantlement & Decommissioning of Facility IR 05000213/19980061999-02-26026 February 1999 Insp Rept 50-213/98-06 on 981103-990118.Violations Noted. Major Areas Inspected:Aspects of Licensee Activities in Preparation for Dismantlement & Decommissioning of Facility. Security Program Was Also Inspected IR 05000213/19980051998-12-21021 December 1998 Insp Rept 50-213/98-05 on 980720-1102.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support ML20155F8511998-10-29029 October 1998 Insp Rept 50-213/98-04 on 980720-0911.Violations Noted. Major Areas Inspected:Aspects of Licensee Preparations, Planning & Implementation of RCS Chemical Decontamination, Operations,Engineering,Maint & Plant Support IR 05000213/19980031998-08-21021 August 1998 Insp Rept 50-213/98-03 on 980414-0803 & 13.Violations Noted. Major Areas Inspected:Operations,Maint,Sf Safety, Decommissioning Activities & Radiological Controls IR 05000213/19980011998-05-13013 May 1998 Insp Rept 50-213/98-01 on 980113-0413.Violations Noted.Major Areas Inspected:Decommissioning Support Activities,Spent Fuel Safety,Plant Support & Radiological Controls & Facility Mgt & Control IR 05000213/19980021998-05-0505 May 1998 Insp Rept 50-213/98-02 on 980316-20 & 25-27.No Violations Noted.Major Areas Inspected:Radiological Control Programs IR 05000213/19970091998-02-17017 February 1998 Insp Rept 50-213/97-09 on 971012-980112.Violations Noted. Major Areas Inspected:Decommissioning Operations & Planning & Included Aspects of Engineering,Maint & Plant Support IR 05000213/19970121998-01-15015 January 1998 Insp Rept 50-213/97-12 on 970812-13 & 1006-09.No Violations Noted.Major Areas Inspected:Status of Rp&C Facilities & Equipment ML20198Q9091998-01-14014 January 1998 Insp Rept 50-213/97-10 on 971008-1128.No Violations Noted. Major Areas Inspected:Plant Support IR 05000213/19970111997-12-29029 December 1997 Insp Rept 50-213/97-11 on 971006-09 & 1103-07.No Violations Noted.Major Areas Inspected:Programs for Radioactive Liquid Control IR 05000213/19970051997-11-26026 November 1997 Insp Rept 50-213/97-05 on 970708-1006.No Violations Noted. Major Areas Inspected:Plant Operations,Maint Engineering & Plant Support ML20199D4621997-11-0707 November 1997 Corrected Pages for Insp Rept 50-213/97-03 on 970408-0707 & 0805 ML20199D4881997-11-0707 November 1997 Corrected Page for Insp Rept 50-213/97-07 on 970715-30 ML20198N2821997-10-29029 October 1997 Insp Rept 50-213/97-08 on 970703,0811-0919.Violations Noted. Major Areas Inspected:Applied Radiological Controls Program, Contamination Control Program & Training of Personnel Relative to 49CFR172,subpart H IR 05000213/19970031997-10-0909 October 1997 Insp Rept 50-213/97-03 on 970408-0707 & 0805.Violations Noted.Major Areas Inspected:Operations,Engineering,Maint & Plant Support IR 05000213/19970071997-08-18018 August 1997 Insp Rept 50-213/97-07 on 970715-30.No Violations Noted. Major Areas Inspected:Plant Support Area IR 05000213/19970061997-08-12012 August 1997 Insp Rept 50-213/97-06 on 970616-0718.Violations Noted. Major Areas Inspected:Radiological Controls Program at Cyap Station,Haddam,Ct ML20149D6211997-06-13013 June 1997 Mgt Meeting Rept 50-213/97-03 on 970528.Areas Discussed: Actions in Response to Findings Detailed in NRC Insp Repts 50-213/96-12.96-201 & 97-01.Deficiencies Involved Implementation of Radiation Protection Program IR 05000213/19970041997-06-0303 June 1997 Physical Security Insp Rept 50-213/97-04 on 970505-08.No Violations Noted.Major Areas Inspected:Previously Identified Items,Mgt Control,Pa Detection Aids,Alarm Stations & Communication,Testing,Maint & Compensatory Measures ML20141F8301997-05-0808 May 1997 Insp Rept 50-213/97-01 on 970106-0407.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000213/19970021997-03-21021 March 1997 Insp Rept 50-213/97-02 on 970207-07 & 0224-26.Violation Noted.Major Area Inspected:Programs for Radioactive Liquid & Gaseous Effluent Control,Including Organization & Effectiveness of Program Implementation ML20136B4471997-02-25025 February 1997 Summary of Meeting Re Insp 50-213/96-12 on 970205 in King of Prussia,Pa to Discuss Findings Detailed in Insp Rept on 961102.Radiation Program Was Deficient in Several Areas That Resulted in Potential Exposure to Radiation ML20138J6751997-02-0404 February 1997 Insp Rept 50-213/96-13 on 961116-970105.Violations Noted. Major Areas Inspected:Plant Operations,Maintenance, Engineering & Plant Support ML20133A5031996-12-24024 December 1996 Insp Rept 50-213/96-11 on 960921-1115.Violations Noted. Major Areas Inspected:Plant Operations,Maint,Engineering & Plant Support ML20132G6211996-12-19019 December 1996 Insp Rept 50-213/96-12 on 961102-27.Apparent Violations Being Considered for Escalated Enforcement Action.Major Areas Inspected:Review of Airborne Radioactivity Event That Occurred on 961102 IR 05000213/19960101996-11-0505 November 1996 Insp Rept 50-213/96-10 on 960811-0920.No Violations Noted. Major Areas Inspected:Plant Operations,Maint,Engineering & Plant Support IR 05000213/19960801996-10-30030 October 1996 Insp Rept 50-213/96-80 on 960903-1002.Violation Noted. Major Areas Inspected:Operations,Maint,Engineering & Mgt Oversight & Controls ML20129F4701996-10-23023 October 1996 Insp Rept 50/213-96-07 on 960813-16.No Violations Noted. Major Areas Inspected:Licensee Performance During Biennial Emergency Preparedness Exercise,Emergency Facility Staffing, Procedure Emplementation & Effectiveness of Mitigation IR 05000213/19940011994-01-24024 January 1994 Insp Rept 50-213/94-01 on 940110-14.No Violations Noted. Major Areas Inspected:Projected Dose Calculation Capability from Radioactive Liquid & Gaseous Effluent Releases IR 05000213/19930211993-12-30030 December 1993 Insp Rept 50-213/93-21 on 931107-1211.Violations Noted. Major Areas Inspected:Plant Operations,Maintenance, Engineering & Technical Support & Plant Support Activities IR 05000213/19930231993-12-17017 December 1993 Insp Repts 50-213/93-23,50-245/93-30,50-336/93-25 & 50-423/93-27 on Stated Date.Violation Noted.Major Areas Inspected:Ffd Program,Policies & Procedures,Ffd Organization & Mgt Control,Training,Chemical Testing & FFD Audit IR 05000213/19930191993-11-23023 November 1993 Insp Rept 50-213/93-19 on 931003-1106.No Violations Noted. Major Areas Inspected:Plant Operations,Maintenance, Engineering & Technical Support & Plant Support Activities IR 05000213/19930161993-11-0404 November 1993 Insp Rept 50-213/93-16 on 930829-1002.No Violations Noted. Major Areas Inspected:Plant Operations,Maintenance, Engineering & Technical Support & Plant Support Activities IR 05000213/19930181993-10-0707 October 1993 Insp Rept 50-213/93-18 on 930927-30.No Safety Concerns or Violations Noted.Major Areas Inspected:Remp,Including Mgt Controls,Qa Audits,Meteorological Monitoring Program & QC Program for Analytical Measurements IR 05000213/19930151993-10-0101 October 1993 Insp Rept 50-213/93-15 on Stated Dates.No Violations Noted.Major Areas Inspected:Generic Ltr 89-10 Program & Related Activities ML20057E6661993-09-29029 September 1993 Insp Rept 50-213/93-16 on 930725-0828.No Violations Noted. Major Areas Inspected:Plant Operations,Maint,Engineering & Technical Support,Plant Support Activities,Outage Assessment & Emergency Planning Drill IR 05000213/19930121993-08-18018 August 1993 Safety Insp Rept 50-213/93-12 on 930620-0724.Violations Noted.Major Areas Inspected:Plant Operations,Outage Activities,Event Response,Maint,Engineering & Technical Support & Plant Support Activities IR 05000213/19920231993-02-0101 February 1993 Insp Rept 50-213/92-23 on 921214-18.Violations Noted.Major Areas Inspected:Ep Program Changes,Emergency Facilities, Equipment,Instrumentation & Supplies,Ep Organization & Management Control,Training & Independent Reviews/Audits IR 05000213/19920221993-01-21021 January 1993 Insp Rept 50-213/92-22 on 921116-20.Violations Noted.Major Areas Inspected:Corrective Actions of Previously Identified Insp Items IR 05000213/19920211993-01-15015 January 1993 Insp Rept 50-213/92-21 on 921115-1212.No Violations Noted. Major Areas Inspected:Plant Operations,Radiological Controls,Maint,Lers & Periodic Repts & Manual Operator Actions During Postulated Station Blackout IR 05000213/19920811993-01-0808 January 1993 Insp Rept 50-213/92-81 on 921005-09 & 29,1112,1210 & 930105 in Region I Ofc.Major Areas Inspected:Licensee Generic Ltr 89-10 Program,Including Scope & Administration of Program, Design Basis Reviews & MOV Training IR 05000213/19920241992-12-30030 December 1992 Insp Rept 50-213/92-24 on 921130-1204.No Violations Noted. Major Areas Inspected:Function of Engineering & Technical Support Reviewed to Evaluate Staffing of Engineering Dept IR 05000213/19920251992-12-22022 December 1992 Insp Rept 50-213/92-25 on 921214-17.No Violations Noted. Major Areas Inspected:Mgt Organization,Training & Assurance of Quality IR 05000213/19920201992-12-15015 December 1992 Insp Rept 50-213/92-20 on 921005-1114.No Violations Noted. Major Areas Inspected:Plant Operations,Radiological Controls,Maint,Surveillance,Licensee self-assessment & Periodic Repts IR 05000213/19900831990-11-0505 November 1990 Insp Repts 50-213/90-83,50-245/90-82,50-336/90-82 & 50-423/90-83 on 900924-28.No Violations Noted.Major Areas Inspected:Licensee Timeliness for Reporting/Operability Determinations IR 05000213/19900821990-10-23023 October 1990 Insp Repts 50-213/90-82,50-245/90-81,50-336/90-81 & 50-423/90-82,on 901001-12.No Violations Noted.Major Areas Inspected:Licensee Occupational Radiation Protection Program Activities During Unit 1 Refueling Outage IR 05000213/19900131990-10-19019 October 1990 Safety Insp Rept 50-213/90-13 on 900801-0911.Good Radiological Controls Performance Noted.Major Areas Inspected:Plant Startup Following 1989/1990 Refueling Outage,Reactor Trips on 900813 & 0903 & Safeguards Problems IR 05000213/19900181990-10-10010 October 1990 Insp Rept 50-213/90-18 on 900926.No Violations Noted 1999-08-20
[Table view] Category:INSPECTION REPORT
MONTHYEARIR 05000213/19990021999-08-20020 August 1999 Insp Rept 50-213/99-02 on 990420-0719.No Violations Noted. Major Areas Inspected:Decommissioning Operations & Sf Safety Maint & Surveillance,Plant Support & Rediological Controls IR 05000213/19990011999-05-21021 May 1999 Insp Rept 50-213/99-01 on 980119-990419.No Violations Noted. Major Areas Inspected:Aspects of Licensee Activities in Preparation for Dismantlement & Decommissioning of Facility IR 05000213/19980061999-02-26026 February 1999 Insp Rept 50-213/98-06 on 981103-990118.Violations Noted. Major Areas Inspected:Aspects of Licensee Activities in Preparation for Dismantlement & Decommissioning of Facility. Security Program Was Also Inspected IR 05000213/19980051998-12-21021 December 1998 Insp Rept 50-213/98-05 on 980720-1102.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support ML20155F8511998-10-29029 October 1998 Insp Rept 50-213/98-04 on 980720-0911.Violations Noted. Major Areas Inspected:Aspects of Licensee Preparations, Planning & Implementation of RCS Chemical Decontamination, Operations,Engineering,Maint & Plant Support IR 05000213/19980031998-08-21021 August 1998 Insp Rept 50-213/98-03 on 980414-0803 & 13.Violations Noted. Major Areas Inspected:Operations,Maint,Sf Safety, Decommissioning Activities & Radiological Controls IR 05000213/19980011998-05-13013 May 1998 Insp Rept 50-213/98-01 on 980113-0413.Violations Noted.Major Areas Inspected:Decommissioning Support Activities,Spent Fuel Safety,Plant Support & Radiological Controls & Facility Mgt & Control IR 05000213/19980021998-05-0505 May 1998 Insp Rept 50-213/98-02 on 980316-20 & 25-27.No Violations Noted.Major Areas Inspected:Radiological Control Programs IR 05000213/19970091998-02-17017 February 1998 Insp Rept 50-213/97-09 on 971012-980112.Violations Noted. Major Areas Inspected:Decommissioning Operations & Planning & Included Aspects of Engineering,Maint & Plant Support IR 05000213/19970121998-01-15015 January 1998 Insp Rept 50-213/97-12 on 970812-13 & 1006-09.No Violations Noted.Major Areas Inspected:Status of Rp&C Facilities & Equipment ML20198Q9091998-01-14014 January 1998 Insp Rept 50-213/97-10 on 971008-1128.No Violations Noted. Major Areas Inspected:Plant Support IR 05000213/19970111997-12-29029 December 1997 Insp Rept 50-213/97-11 on 971006-09 & 1103-07.No Violations Noted.Major Areas Inspected:Programs for Radioactive Liquid Control IR 05000213/19970051997-11-26026 November 1997 Insp Rept 50-213/97-05 on 970708-1006.No Violations Noted. Major Areas Inspected:Plant Operations,Maint Engineering & Plant Support ML20199D4621997-11-0707 November 1997 Corrected Pages for Insp Rept 50-213/97-03 on 970408-0707 & 0805 ML20199D4881997-11-0707 November 1997 Corrected Page for Insp Rept 50-213/97-07 on 970715-30 ML20198N2821997-10-29029 October 1997 Insp Rept 50-213/97-08 on 970703,0811-0919.Violations Noted. Major Areas Inspected:Applied Radiological Controls Program, Contamination Control Program & Training of Personnel Relative to 49CFR172,subpart H IR 05000213/19970031997-10-0909 October 1997 Insp Rept 50-213/97-03 on 970408-0707 & 0805.Violations Noted.Major Areas Inspected:Operations,Engineering,Maint & Plant Support IR 05000213/19970071997-08-18018 August 1997 Insp Rept 50-213/97-07 on 970715-30.No Violations Noted. Major Areas Inspected:Plant Support Area IR 05000213/19970061997-08-12012 August 1997 Insp Rept 50-213/97-06 on 970616-0718.Violations Noted. Major Areas Inspected:Radiological Controls Program at Cyap Station,Haddam,Ct ML20149D6211997-06-13013 June 1997 Mgt Meeting Rept 50-213/97-03 on 970528.Areas Discussed: Actions in Response to Findings Detailed in NRC Insp Repts 50-213/96-12.96-201 & 97-01.Deficiencies Involved Implementation of Radiation Protection Program IR 05000213/19970041997-06-0303 June 1997 Physical Security Insp Rept 50-213/97-04 on 970505-08.No Violations Noted.Major Areas Inspected:Previously Identified Items,Mgt Control,Pa Detection Aids,Alarm Stations & Communication,Testing,Maint & Compensatory Measures ML20141F8301997-05-0808 May 1997 Insp Rept 50-213/97-01 on 970106-0407.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000213/19970021997-03-21021 March 1997 Insp Rept 50-213/97-02 on 970207-07 & 0224-26.Violation Noted.Major Area Inspected:Programs for Radioactive Liquid & Gaseous Effluent Control,Including Organization & Effectiveness of Program Implementation ML20136B4471997-02-25025 February 1997 Summary of Meeting Re Insp 50-213/96-12 on 970205 in King of Prussia,Pa to Discuss Findings Detailed in Insp Rept on 961102.Radiation Program Was Deficient in Several Areas That Resulted in Potential Exposure to Radiation ML20138J6751997-02-0404 February 1997 Insp Rept 50-213/96-13 on 961116-970105.Violations Noted. Major Areas Inspected:Plant Operations,Maintenance, Engineering & Plant Support ML20133A5031996-12-24024 December 1996 Insp Rept 50-213/96-11 on 960921-1115.Violations Noted. Major Areas Inspected:Plant Operations,Maint,Engineering & Plant Support ML20132G6211996-12-19019 December 1996 Insp Rept 50-213/96-12 on 961102-27.Apparent Violations Being Considered for Escalated Enforcement Action.Major Areas Inspected:Review of Airborne Radioactivity Event That Occurred on 961102 IR 05000213/19960101996-11-0505 November 1996 Insp Rept 50-213/96-10 on 960811-0920.No Violations Noted. Major Areas Inspected:Plant Operations,Maint,Engineering & Plant Support IR 05000213/19960801996-10-30030 October 1996 Insp Rept 50-213/96-80 on 960903-1002.Violation Noted. Major Areas Inspected:Operations,Maint,Engineering & Mgt Oversight & Controls ML20129F4701996-10-23023 October 1996 Insp Rept 50/213-96-07 on 960813-16.No Violations Noted. Major Areas Inspected:Licensee Performance During Biennial Emergency Preparedness Exercise,Emergency Facility Staffing, Procedure Emplementation & Effectiveness of Mitigation IR 05000213/19940011994-01-24024 January 1994 Insp Rept 50-213/94-01 on 940110-14.No Violations Noted. Major Areas Inspected:Projected Dose Calculation Capability from Radioactive Liquid & Gaseous Effluent Releases IR 05000213/19930211993-12-30030 December 1993 Insp Rept 50-213/93-21 on 931107-1211.Violations Noted. Major Areas Inspected:Plant Operations,Maintenance, Engineering & Technical Support & Plant Support Activities IR 05000213/19930231993-12-17017 December 1993 Insp Repts 50-213/93-23,50-245/93-30,50-336/93-25 & 50-423/93-27 on Stated Date.Violation Noted.Major Areas Inspected:Ffd Program,Policies & Procedures,Ffd Organization & Mgt Control,Training,Chemical Testing & FFD Audit IR 05000213/19930191993-11-23023 November 1993 Insp Rept 50-213/93-19 on 931003-1106.No Violations Noted. Major Areas Inspected:Plant Operations,Maintenance, Engineering & Technical Support & Plant Support Activities IR 05000213/19930161993-11-0404 November 1993 Insp Rept 50-213/93-16 on 930829-1002.No Violations Noted. Major Areas Inspected:Plant Operations,Maintenance, Engineering & Technical Support & Plant Support Activities IR 05000213/19930181993-10-0707 October 1993 Insp Rept 50-213/93-18 on 930927-30.No Safety Concerns or Violations Noted.Major Areas Inspected:Remp,Including Mgt Controls,Qa Audits,Meteorological Monitoring Program & QC Program for Analytical Measurements IR 05000213/19930151993-10-0101 October 1993 Insp Rept 50-213/93-15 on Stated Dates.No Violations Noted.Major Areas Inspected:Generic Ltr 89-10 Program & Related Activities ML20057E6661993-09-29029 September 1993 Insp Rept 50-213/93-16 on 930725-0828.No Violations Noted. Major Areas Inspected:Plant Operations,Maint,Engineering & Technical Support,Plant Support Activities,Outage Assessment & Emergency Planning Drill IR 05000213/19930121993-08-18018 August 1993 Safety Insp Rept 50-213/93-12 on 930620-0724.Violations Noted.Major Areas Inspected:Plant Operations,Outage Activities,Event Response,Maint,Engineering & Technical Support & Plant Support Activities IR 05000213/19920231993-02-0101 February 1993 Insp Rept 50-213/92-23 on 921214-18.Violations Noted.Major Areas Inspected:Ep Program Changes,Emergency Facilities, Equipment,Instrumentation & Supplies,Ep Organization & Management Control,Training & Independent Reviews/Audits IR 05000213/19920221993-01-21021 January 1993 Insp Rept 50-213/92-22 on 921116-20.Violations Noted.Major Areas Inspected:Corrective Actions of Previously Identified Insp Items IR 05000213/19920211993-01-15015 January 1993 Insp Rept 50-213/92-21 on 921115-1212.No Violations Noted. Major Areas Inspected:Plant Operations,Radiological Controls,Maint,Lers & Periodic Repts & Manual Operator Actions During Postulated Station Blackout IR 05000213/19920811993-01-0808 January 1993 Insp Rept 50-213/92-81 on 921005-09 & 29,1112,1210 & 930105 in Region I Ofc.Major Areas Inspected:Licensee Generic Ltr 89-10 Program,Including Scope & Administration of Program, Design Basis Reviews & MOV Training IR 05000213/19920241992-12-30030 December 1992 Insp Rept 50-213/92-24 on 921130-1204.No Violations Noted. Major Areas Inspected:Function of Engineering & Technical Support Reviewed to Evaluate Staffing of Engineering Dept IR 05000213/19920251992-12-22022 December 1992 Insp Rept 50-213/92-25 on 921214-17.No Violations Noted. Major Areas Inspected:Mgt Organization,Training & Assurance of Quality IR 05000213/19920201992-12-15015 December 1992 Insp Rept 50-213/92-20 on 921005-1114.No Violations Noted. Major Areas Inspected:Plant Operations,Radiological Controls,Maint,Surveillance,Licensee self-assessment & Periodic Repts IR 05000213/19900831990-11-0505 November 1990 Insp Repts 50-213/90-83,50-245/90-82,50-336/90-82 & 50-423/90-83 on 900924-28.No Violations Noted.Major Areas Inspected:Licensee Timeliness for Reporting/Operability Determinations IR 05000213/19900821990-10-23023 October 1990 Insp Repts 50-213/90-82,50-245/90-81,50-336/90-81 & 50-423/90-82,on 901001-12.No Violations Noted.Major Areas Inspected:Licensee Occupational Radiation Protection Program Activities During Unit 1 Refueling Outage IR 05000213/19900131990-10-19019 October 1990 Safety Insp Rept 50-213/90-13 on 900801-0911.Good Radiological Controls Performance Noted.Major Areas Inspected:Plant Startup Following 1989/1990 Refueling Outage,Reactor Trips on 900813 & 0903 & Safeguards Problems IR 05000213/19900181990-10-10010 October 1990 Insp Rept 50-213/90-18 on 900926.No Violations Noted 1999-08-20
[Table view] Category:UTILITY
MONTHYEARIR 05000213/19900831990-11-0505 November 1990 Insp Repts 50-213/90-83,50-245/90-82,50-336/90-82 & 50-423/90-83 on 900924-28.No Violations Noted.Major Areas Inspected:Licensee Timeliness for Reporting/Operability Determinations IR 05000213/19900821990-10-23023 October 1990 Insp Repts 50-213/90-82,50-245/90-81,50-336/90-81 & 50-423/90-82,on 901001-12.No Violations Noted.Major Areas Inspected:Licensee Occupational Radiation Protection Program Activities During Unit 1 Refueling Outage IR 05000213/19900131990-10-19019 October 1990 Safety Insp Rept 50-213/90-13 on 900801-0911.Good Radiological Controls Performance Noted.Major Areas Inspected:Plant Startup Following 1989/1990 Refueling Outage,Reactor Trips on 900813 & 0903 & Safeguards Problems IR 05000213/19900181990-10-10010 October 1990 Insp Rept 50-213/90-18 on 900926.No Violations Noted IR 05000213/19900121990-08-22022 August 1990 Safety Insp Rept 50-213/90-12 on 900621-0731.Major Areas Inspected:Review of Final Refueling Outage Activities, Preparations for Reactor Startup,Exams of safety-related Equipment Readiness & Review of Operational Events IR 05000213/19900081990-07-11011 July 1990 Insp Rept 50-213/90-08 on 900509-0620.Weaknesses Noted.Major Areas Inspected:Plant Operations,Reactor Fuel Reload Activities,Radiological Controls,Loss of Power Testing, Cleaning & Insp of RCS & Insp of Pressurizer Clad Cracks IR 05000213/19900071990-05-18018 May 1990 Insp Rept 50-213/90-07 on 900402-05.No Violations Noted. Major Areas Inspected:Changes to Emergency Plan & Implementing Procedures,Emergency Response Facilities, Equipment & Organization & Mgt Control IR 05000213/19890121989-09-29029 September 1989 Insp Rept 50-213/89-12 on 890726-0905.No Violations Noted. Major Areas Inspected:Plant Operations,Radiation Protection, Fire Protection,Security,Maint,Surveillance Testing,Licensee Events,Open Items & Opening of New Security Access Point IR 05000213/19890141989-09-21021 September 1989 Insp Rept 50-213/89-14 on 890911-15.No Violations or Deviations Noted.Major Areas Inspected:Solid Radwaste Sys, Transportation,Liquid & Gaseous Effluents Programs, Including Mgt Controls,Audits & QA IR 05000213/19890131989-09-15015 September 1989 Insp Rept 50-213/89-13 on 890814-18.No Violations Noted. Major Areas Inspected:Const Activities of New Switchgear Bldg Constructed to Comply W/App R Requirements & Review of Adequacy & Implementation of Fire Protection Program IR 05000213/19890111989-08-24024 August 1989 Safety Insp Rept 50-213/89-11 on 890731-0804.No Violations Noted.Major Areas Inspected:Changes to Emergency Preparedness Program,Emergency Facilities,Equipment, Instrumentation,Supplies & Organization & Mgt Control IR 05000213/19890101989-08-18018 August 1989 Safety Insp Rept 50-213/89-10 on 890614-0725.No Violations & No New Unresolved Items Noted.Major Areas Inspected:Plant Operations,Radiation Protection,Fire Protection,Security, Maint,Surveillance Testing,Open Items & Safety Sys Lineups IR 05000213/19890091989-08-0303 August 1989 Partially Withheld Physical Security Insp Rept 50-213/89-09 on 890626-30 (Ref 10CFR73.21 & 2.790(a)).No Violations Noted.Major Areas Inspected:Mgt Support,Program Plans, Audits & Protected & Vital Area Physical Barriers IR 05000213/19890071989-07-11011 July 1989 Insp Rept 50-213/89-07 on 890503-0613.Violations Noted. Major Areas Inspected:Plant Operations,Radiation Protection, Fire Protection,Security,Maint,Surveillance Testing,Licensee Events & Open Items from Previous Insps IR 05000213/19890081989-07-0707 July 1989 Insp Rept 50-213/89-08 on 890614-16.No Violations Noted. Major Areas Inspected:Radiological Controls Program on Site, Including Changes in Organization,Personnel,Procedures & Review of Preparations for Refueling Outage ML20247J2391989-05-19019 May 1989 Insp Rept 50-213/89-200 on 890130-0210.Weaknesses Noted Re Installation of commercial-grade Items.Major Areas Inspected:Implementation of Vendor Interface Program & Program for Procurement of Items in safety-related Sys IR 05000213/19890051989-05-17017 May 1989 Safety Insp Rept 50-213/89-05 on 890329-0502.Violation Noted.Major Areas Inspected:Plant Operations,Radiation Protection,Fire Protection,Security,Maint,Surveillance Testing & Licensee Events IR 05000213/19890041989-05-12012 May 1989 Insp Rept 50-213/89-04 on 890421-22.No Violations Noted. Major Areas Inspected:Emergency Preparedness & Observation of Licensee partial-participation,emergency Preparedness Exercise Conducted on 890422 IR 05000213/19890021989-05-0303 May 1989 Safety Insp Rept 50-213/89-02 on 890222-0328.No Violations Noted.Major Areas Inspected:Plant Operations,Radiation Protection,Fire Protection,Security,Maint,Surveillance Testing,Events Occurring During Insp & Open Items IR 05000213/19890011989-03-10010 March 1989 Insp Rept 50-213/89-01 on 890104-0221.No Violations Noted. Major Areas Inspected:Plant Operations,Radiation Protection, Fire Protection,Security,Maint,Surveillance Testing,Noble Gas Source Investigation & Reactor Containment Temp IR 05000213/19880191988-12-0101 December 1988 Insp Rept 50-213/88-19 on 880928-1115.No Violations Noted. Major Areas Inspected:Plant Operations,Radiation Protection, Fire Protection,Security,Maint,Surveillance Testing,Licensee Events & Containment Integrated Leak Rate Test Rept IR 05000213/19880211988-11-15015 November 1988 Physical Security Insp Repts 50-213/88-21,50-245/88-22, 50-336/88-25 & 50-423/88-21 on 881017-21.No Noncompliance Noted.Major Areas Inspected:Safeguards Info Program - Corporate Ofcs IR 05000213/19880201988-11-0808 November 1988 Insp Rept 50-213/88-20 on 881014-16.No Violations,Deviations or Unresolved Items Noted.Major Areas Inspected:Emergency Preparedness Exercise Conducted on 881014-16 IR 05000213/19880161988-11-0404 November 1988 Insp Rept 50-213/88-16 on 880830-31 & 0901.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness Program IR 05000213/19880181988-10-14014 October 1988 Insp Rept 50-213/88-18 on 880906-09.No Violations Noted. Major Areas Inspected:Radiological Controls Program, Including Radiation Surveys,Respirator Issue & Maint,Air Sampling Equipment Calibr & Counting Room Operations IR 05000213/19880151988-10-12012 October 1988 Safety Insp Rept 50-213/88-15 on 880801-0912.No Violations Noted.Major Areas Inspected:Plant Operations,Radiation Protection,Fire Protection,Security,Maint,Surveillance Testing,Licensee Events & Open Items from Previous Insps IR 05000213/19880131988-10-0606 October 1988 Insp Rept 50-213/88-13 on 880822-26.No Violations Noted. Major Areas Inspected:Radiochemical Measurements Program, Including Confirmatory Measurements,Program for Qa/Qc of Radiological Measurements & Mgt Controls IR 05000213/19880171988-09-26026 September 1988 Insp Rept 50-213/88-17 on 880822-26.No Violations Noted. Major Areas Inspected:Inservice Insp Program Per ASME Code & Regulatory Requirements IR 05000213/19880141988-08-16016 August 1988 Insp Rept 50-213/88-14 on 880719-22.No Violations Noted. Major Areas Inspected:Concrete Work & Records,Structural Steel Work & Records for New Switchgear Bldg IR 05000213/19880111988-07-31031 July 1988 Insp Rept 50-213/88-11 on 880517-0731.No Violations Noted. Major Areas Inspected:Plant Operations,Radiation & Fire Protection,Security Maint,Surveillance Testing,Switchgear Bldg Const & Open Items from Previous Insps IR 05000213/19880091988-07-22022 July 1988 Insp Rept 50-213/88-09 on 880516-20.No Violations or Deviations Noted.Major Areas Inspected:Steam Generator Inservice Insp,Secondary Water Chemistry Control,Radiation Protection Results & Insp of Other Secondary HXs IR 05000213/19880101988-06-21021 June 1988 Insp Rept 50-213/88-10 on 880523-27.No Violations Noted. Major Areas Inspected:Operational Radiological Environ Monitoring Program,Including Mgt Organization,Environ Sample Collection & Meteorological Monitoring IR 05000213/19880081988-05-27027 May 1988 Safety Insp Rept 50-213/88-08 on 880405-0516.No Violations Noted.Major Areas Inspected:Plant Operations,Radiation Protection,Fire Protection,Security,Maint,Surveillance Testing & Generic Ltrs 87-12 & 81-21 IR 05000213/19880061988-04-21021 April 1988 Insp Rept 50-213/88-06 on 880307-11.No Violations Noted. Major Areas Inspected:Assurance of Readiness for Mode Changes Leading to Power Operation Based on Review of Operations,Mods,Preoperational/Startup & Low Physics Tests IR 05000213/19880031988-04-20020 April 1988 Insp Rept 50-213/88-03 on 880301-0404.No Violations Noted. Major Areas Inspected:Plant Operations,Radiation Protection, Fire Protection,Security,Maint,Surveillance Testing,Licensee Events & Open Items from Previous Insps IR 05000213/19880071988-04-0101 April 1988 Insp Rept 50-213/88-07 on 880314-17.No Violations Noted. Major Areas Inspected:Plan & Implementing Procedures, Organization,Program Audit,Records & Repts,Testing & Maint, Physical Barriers,Protected & Vital Areas & Lighting ML20151C1791988-03-29029 March 1988 Insp Rept 50-213/87-28 on 871116-20.Violations Noted. Major Areas Inspected:Licensee Implementation of Environ Qualification Program & Verification of Implementation Per 10CFR50.49 Requirements ML20148E9981988-03-11011 March 1988 Insp Rept 50-213/88-01 on 880111-21.Violations Noted.Major Areas Inspected:Inservice Test Program Which Included Review of Procedures,Witnessing of Test & Interviewing Test Personnel IR 05000213/19880021988-03-11011 March 1988 Safety Insp Repts 50-213/88-02 on 880113-0229.No Violations Noted.Major Areas Inspected:Outage Activities,Radiation Protection,Fire Protection,Security,Maint,Surveillance Testing & Events Occurring During Insp Period IR 05000213/19880041988-02-24024 February 1988 Insp Rept 50-213/88-04 on 880125-28.No Violations or Deviations Noted.Major Areas Inspected:Licensee Liquid & Gaseous Radioactive Effluents Program,Including Effluent Release Records & Repts IR 05000213/19870291988-01-14014 January 1988 Insp Rept 50-213/87-29 on 871130-1204.No Violations Noted. Major Areas Inspected:Nonradiological Chemistry Program. Areas Reviewed Included Measurement Control & Analytical Procedure Evaluations IR 05000213/19870271987-12-28028 December 1987 Safety Insp Rept 50-213/87-27 on 871009-1207.No Violations Noted.Major Areas Inspected:Plant Operations,Radiation Protection,Fire Protection,Security Maint,Surveillance Testing & Open Items from Previous Insp IR 05000213/19870301987-12-16016 December 1987 Safety Insp Rept 50-213/87-30 on 871116-20.No Violations Noted.Major Areas Inspected:Radiological Controls Program, Including outage-related Exposure Records & ALARA Measures, Whole Body Counting Program & Excreta Bioassay Program IR 05000213/19870221987-12-0404 December 1987 Insp Rept 50-213/87-22 on 870824-0924.Violation Noted.Major Areas Inspected:Safety Significant Activities,Accident Sequences Identified by NUS Probabilistic Safety Study Nusco 149 IR 05000213/19870251987-10-26026 October 1987 Safety Rept 50-213/87-25 on 870826-1008.No Violations Noted. One Unresolved Item Identified.Major Areas Inspected:Plant Outage Activities,Radiation Protection,Fire Protection, Security & Licensee Events IR 05000213/19870261987-10-0505 October 1987 Insp Rept 50-213/87-26 on 870831-0904.No Violations Noted. Major Areas Inspected:Foundation Design & Const Activities for New Switchgear Bldg to Fulfill Licensing Commitments Re Compliance w/10CFR50 App R IR 05000213/19870241987-09-17017 September 1987 Insp Rept 50-213/87-24 on 870810-14.No Violations Noted. Major Areas Inspected:Licensee Surveillance of Vendor Inservice Insp Activities,Review of Inservice Insp NDE Procedures & Balance of Plant Erosion/Corrosion Program IR 05000213/19870211987-09-10010 September 1987 Insp Rept 50-213/87-21 on 870715-0825.Violations Noted. Major Areas Inspected:Plant Operations,Outage Activities, Radiation Protection,Fire Protection,Security,Maint, Surveillance & Events Occurring During Insp Period IR 05000213/19870171987-09-0808 September 1987 Insp Rept 50-213/87-17 on 870727-31.No Violations or Deviations Noted.Major Areas Inspected:Licensee Radiation Protection & Mgt Controls,Personnel Selection,Qualifications & Training,Radwaste Mgt & Facilities & Equipment IR 05000213/19870201987-09-0101 September 1987 Insp Rept 50-213/87-20 on 870720-24.No Violations Noted. Major Areas Inspected:Preparations for 1987 Outage & Program for Control of Contamination by Radioactive Particles 1990-08-22
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARPNO-I-99-039, on 990831,Haddam Neck Plant CR Was Notified by Transportation Contractor,Hittman Transportation Svcs,That Driver of Truck,Left Plant Earlier in Day Noticed Water Leakage from from sea-land Container He Was Transporting1999-09-0101 September 1999 PNO-I-99-039:on 990831,Haddam Neck Plant CR Was Notified by Transportation Contractor,Hittman Transportation Svcs,That Driver of Truck,Left Plant Earlier in Day Noticed Water Leakage from from sea-land Container He Was Transporting IR 05000213/19990021999-08-20020 August 1999 Insp Rept 50-213/99-02 on 990420-0719.No Violations Noted. Major Areas Inspected:Decommissioning Operations & Sf Safety Maint & Surveillance,Plant Support & Rediological Controls IR 05000213/19990011999-05-21021 May 1999 Insp Rept 50-213/99-01 on 980119-990419.No Violations Noted. Major Areas Inspected:Aspects of Licensee Activities in Preparation for Dismantlement & Decommissioning of Facility ML20206R7391999-05-12012 May 1999 Notice of Violation from Investigation on 970616-0718. Violations Noted:On 961209 & 10,J Foley Deliberately Caused Util to Be in Violation of 10CFR50.9 & TS 6.11 & in June 1997 Provided Inaccurate Info to NRC Inspector ML20206R7141999-05-12012 May 1999 Notice of Violation from Investigation on 970314-0722. Violation Noted:M Thomas Engaged in Deliberate Misconduct on 970227,that But for Detection,Would Have Caused Licensee to Be in Violation of 10CFR20.1802 ML20205J8031999-04-0505 April 1999 Notice of Violation from Insp on 961102-27.Violation Noted:Licensee Failed to Adequately Instruct Workers & Failed to Perform Adequate Radiological Surveys in Reactor Cavity & Fuel Transfer Cavity ML20206B3801999-03-29029 March 1999 EN-99-015:informs Commission That Staff Intends to Exercise Discretion Pursuant to Section VII.B.6 of Enforcement Policy & Not Propose Civil Penalty for Severity Level III Problem That Occurred in Nov 1996,prior to Licensee Decision IR 05000213/19980061999-02-26026 February 1999 Insp Rept 50-213/98-06 on 981103-990118.Violations Noted. Major Areas Inspected:Aspects of Licensee Activities in Preparation for Dismantlement & Decommissioning of Facility. Security Program Was Also Inspected ML20207B7041999-02-26026 February 1999 Notice of Violation from Insp on 981103-990118.Violations Noted:Two Different Locked High Radiation Area Doors in Containment Builiding Found Unlocked & Unattended IR 05000213/19980051998-12-21021 December 1998 Insp Rept 50-213/98-05 on 980720-1102.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support ML20155F8511998-10-29029 October 1998 Insp Rept 50-213/98-04 on 980720-0911.Violations Noted. Major Areas Inspected:Aspects of Licensee Preparations, Planning & Implementation of RCS Chemical Decontamination, Operations,Engineering,Maint & Plant Support IR 05000213/19980031998-08-21021 August 1998 Insp Rept 50-213/98-03 on 980414-0803 & 13.Violations Noted. Major Areas Inspected:Operations,Maint,Sf Safety, Decommissioning Activities & Radiological Controls ML20237D4071998-08-21021 August 1998 Notice of Violations from Insp on 980414-0803 & 13. Violations Noted:Licensee Failed to Declare Unusual Event Re 980620 Release of About 800 Gallons of Water Containing Approx 2200 Uci Radioactivity from a Waste Test Tank PNO-I-98-033, on 980728,licensee Identified Leak of Approximately 1,000 Gallons of Demineralized Water & Chemical Agents Used for Decontamination of Plant Sys.Region I Radiation Specialist Will Be Onsite to Review Licensee1998-07-28028 July 1998 PNO-I-98-033:on 980728,licensee Identified Leak of Approximately 1,000 Gallons of Demineralized Water & Chemical Agents Used for Decontamination of Plant Sys.Region I Radiation Specialist Will Be Onsite to Review Licensee IR 05000213/19980011998-05-13013 May 1998 Insp Rept 50-213/98-01 on 980113-0413.Violations Noted.Major Areas Inspected:Decommissioning Support Activities,Spent Fuel Safety,Plant Support & Radiological Controls & Facility Mgt & Control IR 05000213/19980021998-05-0505 May 1998 Insp Rept 50-213/98-02 on 980316-20 & 25-27.No Violations Noted.Major Areas Inspected:Radiological Control Programs IR 05000213/19970091998-02-17017 February 1998 Insp Rept 50-213/97-09 on 971012-980112.Violations Noted. Major Areas Inspected:Decommissioning Operations & Planning & Included Aspects of Engineering,Maint & Plant Support ML20203E6771998-02-17017 February 1998 Notice of Violation from Insp on 971012-980112.Violation Noted:Licensee Did Not Provide for Verifying or Checking Adequacy of Design for Listed Sys & Components IR 05000213/19970121998-01-15015 January 1998 Insp Rept 50-213/97-12 on 970812-13 & 1006-09.No Violations Noted.Major Areas Inspected:Status of Rp&C Facilities & Equipment ML20198Q9091998-01-14014 January 1998 Insp Rept 50-213/97-10 on 971008-1128.No Violations Noted. Major Areas Inspected:Plant Support IR 05000213/19970111997-12-29029 December 1997 Insp Rept 50-213/97-11 on 971006-09 & 1103-07.No Violations Noted.Major Areas Inspected:Programs for Radioactive Liquid Control PNO-I-97-073A, on 971210,update of Offsite Surveys for Contaminated Blocks Made.Total of 114 Blocks Out of 3032 Indicated Radioactive Contamination at Greater than Two Times Background Levels.Licensee Plans to Return to Sites1997-12-11011 December 1997 PNO-I-97-073A:on 971210,update of Offsite Surveys for Contaminated Blocks Made.Total of 114 Blocks Out of 3032 Indicated Radioactive Contamination at Greater than Two Times Background Levels.Licensee Plans to Return to Sites PNO-I-97-074, on 971203,licensee Announced Senior Mgt Restructuring,Which Included Naming New Chairman,President, Chief Executive Officer,Chief Financial Officer & Promotion of Director of Site Operations1997-12-0404 December 1997 PNO-I-97-074:on 971203,licensee Announced Senior Mgt Restructuring,Which Included Naming New Chairman,President, Chief Executive Officer,Chief Financial Officer & Promotion of Director of Site Operations PNO-I-97-073, survey Identified Former Cask Wash Down Area Needing Further Characterization & Remediation within Licensee Control Area.Concrete Blocks Used for Temporary Shield Wall Was Used by 15 Households as of 9711301997-12-0101 December 1997 PNO-I-97-073:survey Identified Former Cask Wash Down Area Needing Further Characterization & Remediation within Licensee Control Area.Concrete Blocks Used for Temporary Shield Wall Was Used by 15 Households as of 971130 IR 05000213/19970051997-11-26026 November 1997 Insp Rept 50-213/97-05 on 970708-1006.No Violations Noted. Major Areas Inspected:Plant Operations,Maint Engineering & Plant Support ML20199D4881997-11-0707 November 1997 Corrected Page for Insp Rept 50-213/97-07 on 970715-30 ML20199D4621997-11-0707 November 1997 Corrected Pages for Insp Rept 50-213/97-03 on 970408-0707 & 0805 ML20198N2761997-10-29029 October 1997 Notice of Violation from Insp on 970703,0811-0919.Violation Noted:On 950222,individual Working on Radiation Work Permit (RWP) 1950603,received Facial Contamination & Not Sent to Be whole-body-counted ML20198N2821997-10-29029 October 1997 Insp Rept 50-213/97-08 on 970703,0811-0919.Violations Noted. Major Areas Inspected:Applied Radiological Controls Program, Contamination Control Program & Training of Personnel Relative to 49CFR172,subpart H IR 05000213/19970031997-10-0909 October 1997 Insp Rept 50-213/97-03 on 970408-0707 & 0805.Violations Noted.Major Areas Inspected:Operations,Engineering,Maint & Plant Support ML20217J3981997-10-0909 October 1997 Notice of Violation from Insp on 970408-0805.Violations Noted:From 960814-970311,licensee Did Not Assure That Significant Condition Adverse to Quality Was Promptly Corrected ML20199B5731997-10-0202 October 1997 EN-97-095:on 971009,staff Intends to Issue Notice of Violation for Two Severity Level III Violations of App B, Criterion Xvi, Corrective Actions. Violations Involved Discovery of Old Plant Design Discrepancy in SWS IR 05000213/19970071997-08-18018 August 1997 Insp Rept 50-213/97-07 on 970715-30.No Violations Noted. Major Areas Inspected:Plant Support Area ML20210P0101997-08-12012 August 1997 Notice of Violation from Insp on 970616-0718.Violation noted:post-dive Diver Tritium Bioassay Sample for 961108 Dive Was Not Shipped as Expeditiously as Possible for Analysis & No Preservative Was Added IR 05000213/19970061997-08-12012 August 1997 Insp Rept 50-213/97-06 on 970616-0718.Violations Noted. Major Areas Inspected:Radiological Controls Program at Cyap Station,Haddam,Ct PNO-I-97-049, on 970807,inadvertent Actuation of Halon Sys Occurred Affecting CR & Adjacent Central Alarm Station. Personnel Took Photographs of Panel of Halon Actuation Panel,Prior to Actuation.Root Cause of Actuation Evaluated1997-08-0808 August 1997 PNO-I-97-049:on 970807,inadvertent Actuation of Halon Sys Occurred Affecting CR & Adjacent Central Alarm Station. Personnel Took Photographs of Panel of Halon Actuation Panel,Prior to Actuation.Root Cause of Actuation Evaluated ML20149D6211997-06-13013 June 1997 Mgt Meeting Rept 50-213/97-03 on 970528.Areas Discussed: Actions in Response to Findings Detailed in NRC Insp Repts 50-213/96-12.96-201 & 97-01.Deficiencies Involved Implementation of Radiation Protection Program IR 05000213/19970041997-06-0303 June 1997 Physical Security Insp Rept 50-213/97-04 on 970505-08.No Violations Noted.Major Areas Inspected:Previously Identified Items,Mgt Control,Pa Detection Aids,Alarm Stations & Communication,Testing,Maint & Compensatory Measures ML20140G4491997-05-12012 May 1997 EN-97-035:on 970512,notice of Proposed Imposition of Civil Penalty in Amount of $650,000 Issued to Licensee.Action Based on Three Severity Level II Problems Consisting of Multiple Individual Violations ML20141D2621997-05-12012 May 1997 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $650,000.Violation Noted:Licensee Did Not Assure That Applicable Regulatory Requirements & Design Basis Were Correctly Translated Into Specifications ML20141F8181997-05-0808 May 1997 Notice of Violation from Insp on 970106-0407.Violation Noted:No RCS Chemistry Samples Were Taken from 961115-970206 ML20141F8301997-05-0808 May 1997 Insp Rept 50-213/97-01 on 970106-0407.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000213/19970021997-03-21021 March 1997 Insp Rept 50-213/97-02 on 970207-07 & 0224-26.Violation Noted.Major Area Inspected:Programs for Radioactive Liquid & Gaseous Effluent Control,Including Organization & Effectiveness of Program Implementation PNO-I-97-014, on 970227,retrieval of Contaminated Matl at Vendor Facility Made.Licensee Dispatched Survey Team, Consisting of HP Supervisor,Hp Technician & Radioactive Matl Handler to Vendor Facility to Survey & Retrieve Matl1997-02-28028 February 1997 PNO-I-97-014:on 970227,retrieval of Contaminated Matl at Vendor Facility Made.Licensee Dispatched Survey Team, Consisting of HP Supervisor,Hp Technician & Radioactive Matl Handler to Vendor Facility to Survey & Retrieve Matl ML20136B4471997-02-25025 February 1997 Summary of Meeting Re Insp 50-213/96-12 on 970205 in King of Prussia,Pa to Discuss Findings Detailed in Insp Rept on 961102.Radiation Program Was Deficient in Several Areas That Resulted in Potential Exposure to Radiation ML20138J6751997-02-0404 February 1997 Insp Rept 50-213/96-13 on 961116-970105.Violations Noted. Major Areas Inspected:Plant Operations,Maintenance, Engineering & Plant Support ML20138J6721997-02-0404 February 1997 Notice of Violation from Insp on 961116-970105.Violation Noted:On 961127,during Preparations to Test EG2B After Jacking Engine,Operator Failed to Remove Crank Over Tool Per Step 6.2.10 Prior to Running Diesel for One Hour Test ML20133A4911996-12-24024 December 1996 Notice of Violation from Insp on 960921-1115.Violation Noted:On 960924,B Residual Heat Removal Pump Failed Due to Inherent Manufacturing Defects & Marginal Design Tolerance ML20133A5031996-12-24024 December 1996 Insp Rept 50-213/96-11 on 960921-1115.Violations Noted. Major Areas Inspected:Plant Operations,Maint,Engineering & Plant Support ML20132G6211996-12-19019 December 1996 Insp Rept 50-213/96-12 on 961102-27.Apparent Violations Being Considered for Escalated Enforcement Action.Major Areas Inspected:Review of Airborne Radioactivity Event That Occurred on 961102 1999-09-01
[Table view] |
Text
. - , 4 m
.
,.a
.
.
.?
U.S. NUCLEAR REGULATORY COMMISSION REGION-I Report N /88-03 Docket'N ,
License N DPR-61 Licensee: Connecticut Yankee Atomic Power Company P. O. Box 270 Hartford, CT 06101
'
Facility: Haddam Neck Plant, Haddam. Neck, Connecticut Inspection at: Haddam Neck Plant Inspection ~ dates: March 1, 1988 through April 4, 1988
.
Inspectors; Andra A. Asars, Resident Inspector John T. Shediosky, Senior Resident Inspector- -
Approved by: , )k 20/E9 E. C. McCabe, Chief, Reactor Projects 18 Date
,
,
Summary: Inspection 50-213/88-03 (3/1/88 - 4/4/88)
Scope. ~ Routine safety inspection (147 hours0.0017 days <br />0.0408 hours <br />2.430556e-4 weeks <br />5.59335e-5 months <br />) by the resident inspectors. Areas i reviewed included plant operations, radiation protection, fire protection, security (including'a short strike by guards), maintenance, surveillance testing, licensee events (including licensee-identified violations), and open items from previous inspections and from the Systematic Evaluation Progra Results. No violations were cited. There were two licensee identified Technical !
. Specification violations: the Residual Heat Removal System was taken out of service -
on two occasions for over one hour (Report Detail 5.2); and a surveillance to .
monitor reactor power during low power physics testing was missed (Report Detail :
5.5). These were acceptably responded to by the licensee. The licensee's contin-gency planning for and response to a guards' strike were found to meet Station Physical Protection Plan commitments (Report Detail 5.3). Licensee actions upon detecting a potential calculational error in large Break LOCA ECCS delivery rates (Report Detail 5.6) were found appropriat l
,
f
8805030148 880421 PDR i
ADOCK 05000213
'
O DCD a
- -- - - . _ - . - . .. -- - - . - . - . .- .-
[
-
,
..
.
.
TABLE OF CONTENTS PAGE Summary of Facility Activities....................................... 1 Plant 0peraticns..................................................... 1 Plant Operations Review Committee.................................... 2 Maintenance and Surve111ance......................................... 2 Followup on Events Occurring During the Inspection................... 3 5.1 Licensee Event Reports and Safeguards Event Reports............. 3 5.2 Premature Shutdown of Residual Heat Removal System.............. 3 5.3 Strike By Bargaining Unit Security Officers..................... 4 5.4 Reactor Trips On Spurious High Startup Rate..................... 5 5.5 Mi ssed Surveillance During Physics Testing. . . . . . . . . . . . . . . . . . . . . . 5 5.6 Large Brea k LOCA ECCS Flow Delivery Error. . . . . . . . . . . . . . . . . . . . . . . 6 Periodic and Special Reports......................................... 7 Inoperable Dropped Rod Circuitry..................................... 7 Systematic Evaluation Program Findings............................... 8 8.1 Topic II-3.B Flooding Potential And Protection Requirements.... 8 8.2 Topic III-3.C, Inservice Inspection of Water Control Structure . Low Temperature Overpressure Protection.............................. 10 10. Exit Interview....................................................... 10
'
,,
.
- ,
.
n-l
,
.
i I
4 DETAILS Summary of Facility Activities The licensee' concluded their four.teenth refueling outage, which began on July 18, 1987. Initial criticality and initiation of Low Power. Physics Testing were on March 19. That same day, the reactor tripped automatically on a spurious high startup rate on Intermediate Range (IR) Channel 22. The reactor was made critical again on March 20. Physics testing continued. A planned manual reactor trip for physics testing was conducted at 10:25 a.m., March 21. The reactor was made critical at 12:06 p.m. the same day. A second automatic reactor trip on spurious high startup rate on IR Channel 22 occurred on March 22. The reactor was made critical later on March 22 and physics testing was completed. On March 24, while below 5% power, the licensee re-ported the discovery of an apparent error in the Large Break LOCA Analysi ,
This precipitated a limit of 40% on power operation. The licensee prepared
~
a Justification For Continued Operation (JCO) at up to 80% Power while the Large Break LOCA-Analysis was reevaluate On March 30, the NRC concurred with the JCO. At the conclusion of this inspection period, the plant was i operating at 80% pcwer and the licensee had submitted a Proposed Technical Specification Change to allow full power operation with the revised Large i
'
Break LOCA Analysi . Plant Operations (71707. 71711)
The inspector observed plant operation during regular tours of the following ,
plant areas ,
,
--
Control Room --
Security Building
--
Primary Auxiliary Building --
Fence Line (Protected Area)
'
--
Vital Switchgear Room --
Yard Areas .
--
Diesel Generator Rooms --
Turbine Building
--
Control Point --
Intake Structure and Pump Building Control room instruments were observed for correlation between channels and for conformance with Technical Specification requirements. The inspector observed various alarm conditions which had been received and acknowledge Operator awareness and response to these conditions were reviewed. Control
, room and shift manning were compared to regulatory requirements. Posting and control of radiation and high radiation areas were inspecte Compliance with Radiation Work Permits and use of appropriate personnel monitoring devices
-
were checked. Plant housekeeping controls were observed, including control and storage of flammable material and other potential safety hazards. The inspector also examined the condition of various fire protection systems.
- Logs and records were reviewed to determine if entries were properly made and
! communicated equipment status / deficiencies. These records included operating
'
logs, turnover sheets, tagout and jumper logs, process competer printouts, and Plant Information Reports. The inspector observed selected aspects of I
- _ _ - _ _ - _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ - _ _ _ _ _ - _ - _ _ - - - - _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ - _ _ _ _ _ _ - _ _ - - _ - _ _ _ _ - _ _ _ _ _ _ _ _ _ _
l '. ,. ,
'
-
!
-
plant security including access control, physical barriers, and personnel monitorun In addition to normal working hours,_the review of plant opera-tions was conducted during the following midnight shifts, and weekends:
--
March 13,~1988 11:00 AM to 4:00 PM
--
March 18, 1988 2:30 AM to 6:00 AM
--
March 20, 1988 2:00 PM to 5:00 PM '
--
March 26,.1988 2:00 PM to 3:00 PM No unacceptable conditions were identified. Operators were alert and dis- ,
played no signs of inattention to duty or fatigu . Plant Operations Review Committee (PORC) (40700)
The 1,1spector attended several Plant Operations Review Committee (PORC) meet- .
ings. Technical specification 6.5 requirements for required member attendance !
were verified. The meeting agenda included procedural changes, proposed changes to the Technical Specifications, and field changes to design change ,
packages. The meeting was characterized by frank discussions and questioning of the proposed changes. In particular, consideration was given to assure ,
clarity and consistency among procedures. Items for which adequate review >
time was not available were postponed to allow committee members time to re- i view and comment. Dissenting opinions were encouraged. 'The inspector had l no furthec comment l 4. Maintenance and Surveillance (61726, 62700)
The inspector observed various maintenance and problem investigation activi- i ties for compliance with requirements and applicable codes and standards, ;
QA/QC involvement, safety tags, equipment alignment and use Mf jumpers, per-
'
sonnel qualifications, radiological controls, fire protection, retest, and reportability. Also, the inspector witnessed selected a rveillance tests to i determine whether properly approved procedures were i i "se, test instrumenta- .
tion was properly calibrated and used, technical specifications were satisfied, ;
testing was performed by qualified personnel, procedure details were adequate,
,
and test results satisfied acceptance criteria or were properly dispositione The following activities were reviewed:
SUR 5.1-18, Test of Emergency Diesel Generator EG-2A With Partial Loss of AC Coincident With Core Cooling Actuation SUR 5.1-19, Test of Emergency Diesel Generator EG-28 With Partial Loss of AC Coincident With Core Cooling Actuation l Routine Operability Surveillances of A & B Emergency Diesel Generators, April 4, 1988 No deficiencies were identifie ;
. .
,
~
.
5. Events Occurring During the Inspection 5.1 Licensee Event " ets (LERs) and Safeguards Event Reports (SERs)
(90713, 937 W The following LERs and SERs were reviewed for clarity, accuracy of the description of cause, and adequacy of corrective action. The inspector determined whether further information was required and whether there were generic impl; cations. The inspector also verified that the report-ing requirements of 10 CFR 50.73, 10 CFR 73.71, and Station Administra-tive, Operating and Security Procedures had been met, that appropriate corrective action had been taken, and that the continued operation of the facility was concucted within Technical Specification Limit Electric Fire Fump Declared Inoperable Due To High Amperage 86-04 Dropped Red Circuitry Found Improperly Wired
- 88-05 Leak Path Renders Cable Vault CO2 System Inoperable 88-06 Leak Path Identified in Cable Vault Flood Barrier 88-501 Safeguards Event Report
- Event detailed in NRC Inspection Report 50-213/88-02 No unacceptable conditions were identifie .2 Premature Shutdown of RHR System (71707, 92702, 93702)
On March 10, during performance of an operating procedure checklist, the licensee identifiec' that, on two occasions during the station heatup from this refueling o/tage, the Residual Heat Removal System (RHR) was not in operation (with the station in mode 5) for more than the one hour period permitted by Technical Specifications (T5s).
Following each outage and during the heatup period, the licensee conducts a hydrostatic pressure test cf the Reactor Coolant System (RCS) at 245 degrees F. During this heatup period, all four RCS loops were unisolated, two reactor coolant pumps (RCPs) were operating, and two steam generato s were unisolated and available for service. Both RHR loops were operable with one operating in accordance with TS 3. 1.4.1. Heatup was hampered by the 'nability to complet.' ' iivert flou around the RHR heat exchangers and procedural limitations the number of RCPs whic' could be operecin In this configuration, end with limited decay heat due to the lengch of the outage, RCS heatup was three degrees per hou __
_______
. .
,
'
-
The two instances of RHR being out of service for greater than one hour with the plant in mode 5 were on March 5 for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />, 2 minutes and on March 10 for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />, 22 minutes. In each case, the plant enterea mode 4 at the end of the time period; in mode 4 it is not required to have
'
an RHR pump operatin The licensee conducted an extensive review of the circumstances which led to this violation of TS 3.3.1.4.1. That Specification was changed by Amendment 97 in November 1987. The previous TS permitted the RHR pumps to be shutdown in mode 5 while performing a plant heatup. When Amendment 97 was issued, the station operating procedures were changed to reflect the new TS, with a precaution statement added to to remind the operators of the new requirement. NOP 2,1-1, Cold Shutdown - Mode 5 to Hot Standby - Mode 3, was in use for the heatup which lasted several day The error is attributed to operations personnel failure to re-review procedural precautions during each shift turnover to ensure pro-cedural adherenc In order to prevent recurrence of events such as this, the licensee took several corrective measures including procedure changes and directing operators' attention to the violation and the necessity of reverifying precautions. The inspectors reviewed the procedure changes made and discussed this event with operations personnel. No inadequacies were identifie These events constitute a violation of TS 3.3.1.4.1. Because they were licensee-identified, appropriately identified to the NRC, appropriately corrected, of limited safety significance (low violation severity) be-cause the steam generators were available to remove decay heat, and judged to not be due to inadequate correction of a previous violation, no notice of violation was issue .3 Strike by Bargaining Unit Security Officers (92709, 92710)
At midnight on March 19, the station bargaining unit Security Officers went on strike af ter rejectir.g a contract renewal of fer from the security contract ,r, Burns International . In anticipation of a possible strike, the licen:,ee had implemented a contingency plan early on March 19 by placing security suparvisory personnel on shift in security officer position The picketil.g was orderly ar.d without incident, and had no effect on plant operations. There was local media coverage of the strik A tentative agreement was reached on March 21, and the security officers returned to their posts on March 2 The contract was ratified on March 2 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ .- _ _ _ _ _ __ _ _ _ _ _ . _ __
.,
.
..
.
Prior to the strike, the inspectors reviewed the contingency plan with security management. During the strike and associated turnover periods, the inspectors observed selected security activities. Additionally, an NRC inspection was performed of the station physical security program implementation during the period March 14 through 17, 1988. Contingency planning was also reviewed during that inspection; details are contained in NRC Report 50-213/88-07. No deficiencies were identified in activi-ties concerning strike contingency planning in either inspectio .4 Reactor Trips on Spurious High Startup Rate (71707, 93702)
The reactor was made critical at 12:55 a.m., March 19 to complete the refueling / maintenance outage and commence low power core physics testin Control rod outward motion was found blocked at 1:57 a.m.; with no pro-gress in solving the oroblem a reactor shutdown was started at 5:24 Inward motion of control rods was not affected. At 5:30 a.m., a reactor trip occurred on high startup rate of one (channel No. 22) of the two intermediate range nuclear instrument channels. At the time, reactor power was in tse intermediate range at 2E-11 amp After extensive investigation the licensee determined that an annunciator relay created an electrical noise spike in the intermediate range channe The problem was corrected by the addition of a suppression diode across the relay coil. A failed relay was found to have caused the outward rod motiun block and was replace The reactor was again made critical at 7:38 p.m., March 2 A second automatic reaccor trip occurred at 6:24 a.m., March 22. Again the trip was initiated by the high start up rate protective circuit of Incermediate Range channel No. 22. Reactor power was in the intermediate range at 2E-9 arnps during reactivity temperature coefficient measurement The plant had been maintained in a very stable configuration prior to the trip to support of the isothermal temperature measurements. Power was allowed to change slowly during those tests and had decreased to the point where Intermediate Range Channel No. 22 energized the source range detector high voltage. The licensees corrective actions included re-placement of components within the intermediate range instrument along with a length of electrical cable at the detector. The reactor was again mada critical at 8:00 p.m., March 22 and testing of the new low pressure tur..ne bega .5 Missed Surveillance During Physics Testing (71707, 92702, 93702)
During Low Power Physics Testing, the Special Test Exceptions of Techni-cal Specification (TS) 3.24.2 require that reactor thermal power be verified te be below 5% hourly. On March 21, while conducting physics testing, $ne licensee identified that they had missed one of these hourly surveillances by 42 minutes. Test personnel immediately verified that reactor thermal power was indeed less than 5%. Actual power was 0.02%.
/-
.
-
.
The licensee attributed this missed surveillance to personnel erro Because the plant process computer calorimetric program had not yet been fully tested and turned over, test personnel had to perform hand calcu-lations. The importance of performing these calculations on time was re-emphasized to test personnel. In the future, the licensee expects to have the plant process computer calorimetric program fully operatiena When this is the case, reactor power will be automatically calculated as necessary. Should hand calculations be required again, test personnel will be reminded of the hourly calculation requiremen There were no further instances of missed calculations during the physics test The inspector concluded that this licensee-identified event was appropriately corrected and reported, of minor safety significance, and not due to corrective action inadequacy on a previous violatio Therefore, no Notice of Violation was issue .6 Large Breat LOCA ECCS Flow Delivery Error (40701, 71707, 93702]
The NRC Resident Inspectors were informed of the discovery of a pctential error in the Emergency Core Cooling System (ECCS) flow delivery calcula-tions which were used as an input parameter in the Large Break Loss of Coolant Accident (LB-LOCA) analysis. At the time, the reactor wa; cri-tical in Mode 2, with power less than 5%.
The licensee has be:n performing an in-house LB-LOCA analysis. As part of that effort, the licensee recalculated the ECCS flow delivery rates with single active components as the input to the analysis. A discre-pancy was found between the results of their calculations and those pro-vided by the Nuclear Steam Supply System vendor, Westinghouse, in t' e original ECCS performance analysis docketed in 1971. Both the licensee and Westinghouse calculated ECCS delivery flow rates with assumed active component f ailures (that is a failed emergency "iesel generator, injec-tion valve, high pressure or low pressure injection pump). The licensee determined that limiting flow would occur with a failed shut Low Pressure Safety Injection isolation / injection valve at 866 lb mess /secon For the same failure ;lestinghouse calculated 1140 lb mass /second. The limiting Westinghouse case had been calculated as the failure of an emergency diesel generator (1060 lb mass /second). At the end of the inspection period, *.he licensee and Westinghouse were working to resolve the diff.renc However, since the case with one failed emergency gene-rator was ast med to be limiting and is the basis for the current LB-LOCA licensing ant > sis, it was conservatively assumed that the later, licen-see calculatisas were correct. Westinghouse was also recalculating the l LB-LOCA analysi The results are expected to be available during the f
week of April A conf once call was conducted between the licensee and the NRC - NRR at 4:10 p.m., March 24 The licensee explained the issue and was asked to provida a Justification for Continued Operation (JCO) at up to 40%
power prior to entering Mode That document was provided early in the evening of March 25 and was Dased on sensitivity studies which concluded . .
.
'
that a delivery rate at 80% of that previously assumed would result in post-LB-LOCA peak clad temperatures (PCT) of about 100 degrees above the Interim Acceptance Criteria (IAC) limit of 2300 degrees F (for stainless steel clad). To reduce PCT to within the IAC limit, the sensitivity studies also indicated that peak Linear Heat Generation Rate (LHGR)
needed to be reduced frora 14.3 to 13.3 kw/ft. Changes in LHGR also re-quired re-evaluation of axial offset limits, however a change in limits at 80% power and below were not recuire The licensee began a power increase and entered Mode 1 (5%) at 3:45 p.m.,
March 2 Turbine and generator voltage regulator testing were completed and plant power was held at 30% on March 28 to allow chemical cleanup of the steam generator secondary. At a 10:00 a.m., March 30 meeting the NRC - NRR concurred with the licensee's JC0 for up to 80% of rated powe Power was increased to 79% at 4:00 p.m., March 3 During this period the NRC Resident Inspectors monitored plant operations to insure that tne limiting conditions set by the licensee and agreed to by the NRC were implemente There were no unacceptable conditions identifie . Periodic and Special Reports (90713)
Upon receipt, periodic and special reports submitted pursuant to Technical Specification 6.9 were reviewed. This review verified that the reported in-formation was valid and included the NRC required data; that test results and supporti a information were consistent with design predictions and performance specifications; and that planned corrective actions were adequate for resolu-tion of the p;oble The inspector also ascertained whether any reported information should be classified as an abnormal occurrence. The following periodic report was reviewed:
--
Monthly Operating Report 88-02, February 1-29, 1988 No inadequacies were identifie .0 Inopecable Dropped Rod Circuitry (37701, 93702)
On February 25, during additional post modification testing of the dropped rod circuitry, the licensee identified that the circuitry for rods 12 and 13 in Control Bank B was improperly wire In this configuration, had one of 1 these rods dropped, there would not have been an initiation of the P3 permis-sive. Energi ation of the P3 relay initiates a turbine load runback to 80%
power and a block of automatic control rod withdrawa Earlier in the refueling outage, the licensee had made a minor modification to delete the bypass feature of the dropped rod circuitry. This bypass fea-ture allowed the dropped rod circuitry to be bypassed when Bank B rods were below a preset height to avoid inadvertent actuation of the P3 permissiv This feature was determined to not be necessary because, when Bank B is in-serted into the core, power level is generally below 80% and, when performing
- __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ - _ _ _ _ - _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _
'
.
.
.
.
.
a startup, control rods are withdrawn manually, not automatically. Post modification testing for this design change was conducted under SPL 10.2-48, Functional Verification of PDCR 924 (Dropped Rod Block Removal). This test verified circuit operability by individually energizing each bank relay (to simulate control rods inserted into the core) and verifying that the P3 relay was energize During test development and performance, test personnel ques-tiened how~ individual rod bottom signals feeding into the P3 function were verifie I&C personnel review of the rod position calibration procedure SUR 5.2-21, Rod Position Calibration, identified that the contact which feeds the rod bottom signal into the P3 function was not periodically verified. As a result, additional testing was performed on the dropped rod circuitr .
'
The additional testing simulated an individual dropped rod by systematically bypassing all but one bistable associated with each bank to initiate relay operation to energize the P3 relay. On February 25, it was identified that, had rods 12 and 13 of Bank B dropped, there would not be the associated energization of the P3 relay. Complete testing of all 45 control rods iden-tified no further inadequacies. Rcpairs and retesting were successfully per-formed on the circuitry for rods 12 and 13 of Bank The licensee has attributed the error in the wiring to pear post modification testing after modifications made to the circuitry several years ago. Current post modification testing practices have greatly imoroved and have identified several errors from previous modifications during this refueling outag Additionally, the Dropped Rod Analysis in the Updated Final Safety Analysis Report does not take credit for the turbine load runback or dropped rod sto Therefore, P3 does not have a safety-related function. The licensee had ad-ministratively downgraded the P3 permissive to control grade but maintains it to provide optimal station response to a dropped rod event. The inspector had no further questions on this matte .0 Systematic Evaluation Program Findings [92719]
8.1 Topic 11-3.8, Flooding Potential and Protection Requirements This topic addresses potential floods and required protection; including the type of protection, equipmert necessary, and implementation of the protection program. The portion of this topic which had not been veri-fied complete before this inspection period is the licensee's emergency procedures to initiate flood protection i..easures. This also has been identified as Integrated Plant Safety Assessment Report (IPSAR) Item e 4.1.4, Emergency Procedure In previous inspections, this item had been verified complete and close However, after the flood of June 1984, this issue was reopened when the licensee elected to make a major procedural change. Specifically, Ab-normal Operating Procedure (AOP) 3.2-24, Flooding of the Connecticut River, had required that protective measures be initiated when river water level reaches 16 feet mean sea level (M5L). (Site grade elevation
.
,
.
'
.
is 21 feet MSL.) The licensee wanted to change the action level to re-quire protective measures when the river reaches 16 feet MSL only if it is predicted to rise above 21 feet MSL. A review of the procedure, the area flooding history, and flood prediction capabilities was conducted by the NRC. It was determined adequate to initiate flood protection measures when the river reaches 16 feet NSL and there is a predicted crest above 19 feet MSL. NRC also recommended several additional changes to the A0P. The inspector reviewed the current revision (Revision 7)
of A0P 3.2-24 and verified that necessary changes have been incorporate This item is close . t. Topic III-3.C, Inservice Inspection of Water Control Structures This topic required an Inservice Inspection Program for Water Control Structures (WCSs). WCSs are used for flood protection or emergency core cooling systems. The program ensures that WCSs which are part of the ultimate heat sink are available at all times under normal and accident conditions. This issue also is IPSAR Item Final NRC review of this program was completed with the issuance of the Safety Evaluation, dated April 7, 1987. At that time, the licensee had not fully implemented commitments to assign a qualified engineer to supervise this program, maintain a central file for program inspection results, and perform a review of Regulatory Guide 1.127, Inspection of Water Control Structures Associated With Nuclear Power Plants, to ensure that Hacdam Nec'< complies to the extent possibl The inspector discussed the implementation of these commitments with the assigned engineer. Early in 1987, the licensee hired a Civil Engineer to oversee the WCS Inspection Program. The actual inspections are per-formed by this engineer and qualified corporate engineers. The licensee also reviewed Reg Guide 1.127 and elec.ted to develop several procedures to implement its recommen6 tion Fpecifically, ACP 1.0-51, Water Con-trol Structures / Flood Protection Barrier Inspection Program, was estab-lished as the controlling document for the WCS Inspection Program. It delineates the personnel responsibilities and identifies 1spection pro-cedures for WCS/ Flood Protection Barriers. The WCS Inspection Program is implerented by several Engineering and Preventive Maintenance Proce-dures. The central file for the completed inspection and maintenance i procedures is the Nuclear Records Department onsite.
!
'
The inspector reviewed the completed inspection and maintenance proce-dures from this refueling outage and verified that any discrepancies identified were adequately addressed through the Nonconformance Report process. The inspector also verified that the corporate engineers per-forming these inspections have appropriate, documented qualifications.
'
Based on this review, this item is closed.
l l
i I
_ _ _ _ _ _ _ - _ _
w ',
.
.
- 10
,
9.0 Low Temperature Overpressure orotection (LTOP) (25019)
Reactor vessel integrity can be threatened by sudden pressure increases com-bined with low reactor coolant system temperatures. This issue has been identified as Unresolved Safety Issue (USI) A-26: Reactor Vessel Pressure Transient Protection for Pressurized Water Reactors. Numerous reviews of licensee actions to resolve this issue have been performed. These are docu-mented in NRC Inspection Reports 50-213/85-21, 86-01, 87-06, 87-08, 87-21, and 87-27. Throughout these inspections, reviews have been made of the lic-ensee's LTOP design reviews, station drawings, administrative controls, sur-veillance and operations procedures, operator training, and Technical Speci-fication (TS) amendments. During this inspection period, the insptetor veri-fied that station procedures reflect the most recent TS amendments. Based on these reviews, the licensee has adequately addressed the concerns raised by USI A-2 . Exit interview (30703)
During this inspection, meetings were held with plant management to discuss the findings. No proprietary information related to this inspection was identified.