PNO-II-85-120, on 851119 & 1217,concentrated Hydrazine/ Ammonia Mixture Leaked from Steam Generator Vent Valve. Personnel Evacuated.Several Cases of Breathing Difficulties Noted
ML20138Q159 | |
Person / Time | |
---|---|
Site: | Vogtle ![]() |
Issue date: | 12/20/1985 |
From: | Brownlee V, Sinkule M NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
To: | |
References | |
PNO-II-85-120, NUDOCS 8512270074 | |
Download: ML20138Q159 (1) | |
Similar Documents at Vogtle | |
---|---|
Category:PRELIMINARY NOTIFICATION OF EVENT OR OCCURRENCE (PNO
MONTHYEARPNO-II-98-032, on 980609,electrical Fault on 2C Condensate Pump Motor Caused Loss of 1NAB 13.8KV Bus.Fault Also Caused Main Generator Trip,Turbine Trip & Reactor Trip.Reactor Coolant Pump 2 & 4 Lost Power Because of Bus Loss1998-06-10010 June 1998
[Table view]PNO-II-98-032:on 980609,electrical Fault on 2C Condensate Pump Motor Caused Loss of 1NAB 13.8KV Bus.Fault Also Caused Main Generator Trip,Turbine Trip & Reactor Trip.Reactor Coolant Pump 2 & 4 Lost Power Because of Bus Loss PNO-II-98-017, on 980320,female Contract Worker Found Unconscious at Bottom of man-lift Station in Turbine Bldg. Plant First Aid Team Responded & Ambulance Was Called. Injured Person Transported to Hosp & Pronounced Dead1998-03-20020 March 1998 PNO-II-98-017:on 980320,female Contract Worker Found Unconscious at Bottom of man-lift Station in Turbine Bldg. Plant First Aid Team Responded & Ambulance Was Called. Injured Person Transported to Hosp & Pronounced Dead PNO-II-93-055, on 931007,unusual Event Declared Due to Toxic Gas Release Into Unit 2 Control Room Bldg.Chemical Concentrations in Bldg Exceeded Threshold Limit for Chemicals.Personnel Evacuated & Purge of Areas in Progress1993-10-0707 October 1993 PNO-II-93-055:on 931007,unusual Event Declared Due to Toxic Gas Release Into Unit 2 Control Room Bldg.Chemical Concentrations in Bldg Exceeded Threshold Limit for Chemicals.Personnel Evacuated & Purge of Areas in Progress PNO-II-93-054, on 931001,media Reported That Whistleblower Won One Million Dollars in Damages as Result of Civil Action Initiated by Whistleblower Against Three Westinghouse Engineers Who Allegedly Conspired to Fire Whistleblower1993-10-0606 October 1993 PNO-II-93-054:on 931001,media Reported That Whistleblower Won One Million Dollars in Damages as Result of Civil Action Initiated by Whistleblower Against Three Westinghouse Engineers Who Allegedly Conspired to Fire Whistleblower PNO-II-89-066A, updates Status of Hurricane Hugo for Nuclear Facilities in Southeast.Manning of Incident Response Ctr by Region II Continuing1989-09-21021 September 1989 PNO-II-89-066A:updates Status of Hurricane Hugo for Nuclear Facilities in Southeast.Manning of Incident Response Ctr by Region II Continuing PNO-II-89-027, on 890328,initial Criticality Achieved within Estimated Critical Conditions.Regional Specialist & Resident Inspector Observed Reactor Startup.Low Power License Received on 890209.Commission Briefing Set for 8903301989-03-28028 March 1989 PNO-II-89-027:on 890328,initial Criticality Achieved within Estimated Critical Conditions.Regional Specialist & Resident Inspector Observed Reactor Startup.Low Power License Received on 890209.Commission Briefing Set for 890330 PNO-II-89-013, on 890221,chemical Technician in Demineralized Water Plant Slipped Because of Oil Film on Room Floor.In Falling,Technician Broke Instrument Line Containing Sulfuric Acid & Received Chemical Burns on 15% of Body1989-02-21021 February 1989 PNO-II-89-013:on 890221,chemical Technician in Demineralized Water Plant Slipped Because of Oil Film on Room Floor.In Falling,Technician Broke Instrument Line Containing Sulfuric Acid & Received Chemical Burns on 15% of Body PNO-II-88-058, on 880916,electrician Employed by Catalytic Industrial Maint Co Had Heart Attack Outside Plant Protected Area Near Cooling Towers.Employee Pronounced Dead at Hosp1988-09-16016 September 1988 PNO-II-88-058:on 880916,electrician Employed by Catalytic Industrial Maint Co Had Heart Attack Outside Plant Protected Area Near Cooling Towers.Employee Pronounced Dead at Hosp PNO-II-88-028, on 880424,unit Manually Tripped from 100% Power for More than 48 H in Order to Complete Repairs on Main Feedwater Isolation & Replace Transformer.Licensee Action Monitored by Resident Inspector1988-04-26026 April 1988 PNO-II-88-028:on 880424,unit Manually Tripped from 100% Power for More than 48 H in Order to Complete Repairs on Main Feedwater Isolation & Replace Transformer.Licensee Action Monitored by Resident Inspector PNO-II-87-035, on 870601,Georgia Power Co Declared Facility in Commercial Operation Following Completion of 100 H Warranty Run at 100% Power on 8705311987-06-0101 June 1987 PNO-II-87-035:on 870601,Georgia Power Co Declared Facility in Commercial Operation Following Completion of 100 H Warranty Run at 100% Power on 870531 PNO-II-87-031, on 870519,low Level Radioactively Contaminated Water Leaked Into Turbine Bldg.Caused by Pressurization of Crud Tank.Some Contaminated Water Diluted & Discharged Into Savannah River.Decontamination Efforts Continuing1987-05-21021 May 1987 PNO-II-87-031:on 870519,low Level Radioactively Contaminated Water Leaked Into Turbine Bldg.Caused by Pressurization of Crud Tank.Some Contaminated Water Diluted & Discharged Into Savannah River.Decontamination Efforts Continuing PNO-II-87-028, on 870513,device Suspected of Being Bomb Was Identified.Licensee Declared Security Alert & FBI Notified. Device Determined by Bomb Squad to Be Nonexplosive1987-05-13013 May 1987 PNO-II-87-028:on 870513,device Suspected of Being Bomb Was Identified.Licensee Declared Security Alert & FBI Notified. Device Determined by Bomb Squad to Be Nonexplosive PNO-II-87-016, on 870309,Vogtle Unit 1 Achieved Initial Criticality.Nrc Senior Resident Inspector & Region II Specialist Were Present.All Parameters Were Reported to Be Near Anticipated Values1987-03-0909 March 1987 PNO-II-87-016:on 870309,Vogtle Unit 1 Achieved Initial Criticality.Nrc Senior Resident Inspector & Region II Specialist Were Present.All Parameters Were Reported to Be Near Anticipated Values PNO-II-87-008, on 870116,low Power License Issued.Problem Experienced W/Fuel Upender on Fuel Handling Side While Loading First Element.Problem Corrected.Resident Inspector Monitoring Efforts to Correct Source Range Monitor NI-311987-01-21021 January 1987 PNO-II-87-008:on 870116,low Power License Issued.Problem Experienced W/Fuel Upender on Fuel Handling Side While Loading First Element.Problem Corrected.Resident Inspector Monitoring Efforts to Correct Source Range Monitor NI-31 PNO-II-86-019, on 860303,const Employee Suffered Fatal Injuries After Falling 40 Ft Down Turbine Bldg Elevator Shaft.Employee Attempting to Open Door When Elevator Suddenly Opened.Licensee Responding to Media1986-03-0404 March 1986 PNO-II-86-019:on 860303,const Employee Suffered Fatal Injuries After Falling 40 Ft Down Turbine Bldg Elevator Shaft.Employee Attempting to Open Door When Elevator Suddenly Opened.Licensee Responding to Media PNO-II-86-005, on 860111,plant Swtichboard Operator Received off-site Call from Unidentified Male,Stating That There Was Bomb in Power Block Set to Go Off at Noon.Caller Stated He Had on Bomb.Search for Bomb Proved Negative1986-01-13013 January 1986 PNO-II-86-005:on 860111,plant Swtichboard Operator Received off-site Call from Unidentified Male,Stating That There Was Bomb in Power Block Set to Go Off at Noon.Caller Stated He Had on Bomb.Search for Bomb Proved Negative PNO-II-85-120, on 851119 & 1217,concentrated Hydrazine/ Ammonia Mixture Leaked from Steam Generator Vent Valve. Personnel Evacuated.Several Cases of Breathing Difficulties Noted1985-12-20020 December 1985 PNO-II-85-120:on 851119 & 1217,concentrated Hydrazine/ Ammonia Mixture Leaked from Steam Generator Vent Valve. Personnel Evacuated.Several Cases of Breathing Difficulties Noted PNO-II-85-119, on 851216,painter Fell 20 Ft from Scaffold While Working in Containment.Painter Hospitalized in Stable Condition,But W/Serious Head & Back Injuries.State of Ga & OSHA Notified1985-12-17017 December 1985 PNO-II-85-119:on 851216,painter Fell 20 Ft from Scaffold While Working in Containment.Painter Hospitalized in Stable Condition,But W/Serious Head & Back Injuries.State of Ga & OSHA Notified PNO-II-85-099, on 851022,telephone Threat Received from Recently Terminated Worker Threatening to Blow Up General Carpentry Laborer Assigned to Turbine Bldg Area.Area Searched.No Bomb Found1985-10-23023 October 1985 PNO-II-85-099:on 851022,telephone Threat Received from Recently Terminated Worker Threatening to Blow Up General Carpentry Laborer Assigned to Turbine Bldg Area.Area Searched.No Bomb Found PNO-II-85-060, on 850613,device Rigged to Resemble Homemade Bomb Found in Area Inside Equipment Hatch.Licensee Officials Evacuated Area.Police Bomb Squad Assistance Requested.Device Described as Flashlight Battery & Wires1985-06-13013 June 1985 PNO-II-85-060:on 850613,device Rigged to Resemble Homemade Bomb Found in Area Inside Equipment Hatch.Licensee Officials Evacuated Area.Police Bomb Squad Assistance Requested.Device Described as Flashlight Battery & Wires PNO-II-83-086, on 831102,employee of Moser Iron Works Was Fatally Injured When He Fell 27 Feet from Structural Beam in Unit 2 Containment Building.Licensee Responding to Inquiries.Nrc Does Not Plan News Release1983-11-0202 November 1983 PNO-II-83-086:on 831102,employee of Moser Iron Works Was Fatally Injured When He Fell 27 Feet from Structural Beam in Unit 2 Containment Building.Licensee Responding to Inquiries.Nrc Does Not Plan News Release PNO-II-83-069, on 830901,GPC Sent 3300 Employees Home for Day as Result of Telephoned Bomb Threat.Caller Said Five Pounds of Plastic Explosives Would Go Off in Power Block.Licensee Believes Threat Related to Layoff of 600 Employees1983-09-0101 September 1983 PNO-II-83-069:on 830901,GPC Sent 3300 Employees Home for Day as Result of Telephoned Bomb Threat.Caller Said Five Pounds of Plastic Explosives Would Go Off in Power Block.Licensee Believes Threat Related to Layoff of 600 Employees PNO-II-82-068, on 820617,stop Work Order Issued on Use of Class 2 & 3 4-1/2 Inch or Larger Piping Spool Pieces Supplied by Pullman Power Products Due to Presence of Surface Defects.Audit to Be Performed at Fabrication Shop1982-06-17017 June 1982 PNO-II-82-068:on 820617,stop Work Order Issued on Use of Class 2 & 3 4-1/2 Inch or Larger Piping Spool Pieces Supplied by Pullman Power Products Due to Presence of Surface Defects.Audit to Be Performed at Fabrication Shop ML20249A6261978-06-28028 June 1978 PNS-78-030:on 780628,twelve Members of Protest Group, Southerners Mobilizing for Survival,Visited Region II Ofc to Stage Protest Against Licensing of Seabrook Nuclear Plant & to Request That Work Be Halted at Vogtle Plant 1998-06-10 Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS MONTHYEARIR 05000424/19990061999-10-0101 October 1999
[Table view]Insp Repts 50-424/99-06 & 50-425/99-06 on 990725-0904. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000424/19990051999-08-16016 August 1999 Insp Repts 50-424/99-05 & 50-425/99-05 on 990620-0724.No Violations Noted.Major Areas Inspected:Opertions, Engineering,Maintenance & Plant Support.Results of Announced Insp by Security Inspector Also Encl IR 05000424/19990041999-07-15015 July 1999 Insp Repts 50-424/99-04 & 50-425/99-04 on 990502-0619. Non-cited Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000424/19990031999-05-19019 May 1999 Insp Repts 50-424/99-03 & 50-425/99-03 on 990321-0501. Non-cited Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000424/19990021999-04-15015 April 1999 Insp Repts 50-424/99-02 & 50-425/99-02 on 990214-0320. Violations Noted.Major Areas Inspected:Operations, Engineering,Maint & Plant Support ML20207L8511999-03-0808 March 1999 Notice of Violation from Insp on 990125-27.Violation Noted: on Numerous Occasions from Mar 1997 to Oct 1998,select Response Force Officers Were Posted in Locations That Would Not Permit Them to Interpose Themselves Between Intruder IR 05000424/19990011999-03-0808 March 1999 Partially Withheld Insp Repts 50-424/99-01 & 50-425/99-01 on 990125-27 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Area of Plant Support by Regional Safeguards Inspector & Select Personnel from NRR IR 05000424/19980101999-03-0303 March 1999 Insp Repts 50-424/98-10 & 50-425/98-10 on 981227-990213.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support.Rept Covers 7-wk Period of Insp & Insps in Area of Health Physica & EP IR 05000424/19980091999-01-20020 January 1999 Insp Repts 50-424/98-09 & 50-425/98-09 on 981115-1226.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000424/19980081998-12-11011 December 1998 Insp Repts 50-424/98-08 & 50-425/98-08 on 980927-1114.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000424/19980121998-11-0909 November 1998 Partially Withheld Insp Repts 50-424/98-12 & 50-425/98-12 on 981005-09 (Ref 10CFR73.21)Major Areas Inspected:Physical Security Program for Power Reactors ML20155A7621998-10-15015 October 1998 Notice of Violation from Insp on 980816-0926.Violation Noted:On 980824,licensee Failed to Adequately Establish Sufficient Procedural Control for Demolition of Concrete Missile Barrier IR 05000424/19980071998-10-15015 October 1998 Insp Repts 50-424/98-07 & 50-425/98-07 on 980816-0926. Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support.Insp Also Addressed 980904 Reactor Trip IR 05000424/19980061998-09-10010 September 1998 Insp Repts 50-424/98-06 & 50-425/98-06 on 980628-0815.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support ML20154C5131998-09-10010 September 1998 Notice of Violation from Insp on 980628-0815.Violation Noted:Corrective Actions Taken in Response to Violations Associated with Entry Into TS LCO for Maint & Surveillances Activities Were Inadequate to Preclude Repetition IR 05000424/19980111998-07-31031 July 1998 Insp Repts 50-424/98-11 & 50-425/98-11 on 980622-26.No Violations Noted.Major Areas Inspected:Announced Insp Was Observation & Evaluation of Biennial Emergency Preparedness Exercise for Plant ML20236T5871998-07-23023 July 1998 Notice of Violation from Insp on 980517-0627.Violation Noted:On 980419,Unit 2 Entered Mode 2 W/O Meeting LCO of TS 3.3.2,which Requires Two Trains of Turbine Trip Function to Be Operable Prior to Entering Mode 2 IR 05000424/19980051998-07-23023 July 1998 Insp Repts 50-424/98-05 & 50-425/98-05 on 980517-0627. Violation Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000424/19983021998-07-21021 July 1998 NRC Operator Licensing Exam Repts 50-424/98-302 & 50-425/98-302 for Tests Administered on 980721 ML20236H3971998-06-15015 June 1998 Notice of Violations from Insp on 980419-0516.Violations Noted:On 980415,upon Identification That 1 of 3 Letdown Orifice Isolation Valves Would Not Open,Unit 2 Uss Proceeded to Allow Operation of Unit in Water Solid Conditions ML20236H4081998-06-15015 June 1998 Insp Repts 50-424/98-04 & 50-425/98-04 on 980419-0516. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support PNO-II-98-032, on 980609,electrical Fault on 2C Condensate Pump Motor Caused Loss of 1NAB 13.8KV Bus.Fault Also Caused Main Generator Trip,Turbine Trip & Reactor Trip.Reactor Coolant Pump 2 & 4 Lost Power Because of Bus Loss1998-06-10010 June 1998 PNO-II-98-032:on 980609,electrical Fault on 2C Condensate Pump Motor Caused Loss of 1NAB 13.8KV Bus.Fault Also Caused Main Generator Trip,Turbine Trip & Reactor Trip.Reactor Coolant Pump 2 & 4 Lost Power Because of Bus Loss ML20247K7531998-05-15015 May 1998 Notice of Violation from Insp on 980308-0418.Violation Noted:On 980401,Procedure PT-V-605,was Not Properly Implemented,In That,Liquid Penetrant pre-exam Cleaning for Safety Injection Sys Weld 21204-122-6 Was Inadequate IR 05000424/19980031998-05-15015 May 1998 Insp Repts 50-424/98-03 & 50-425/98-03 on 980308-0418. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000424/19983011998-05-0707 May 1998 NRC Operator Licensing Exam Repts 50-424/98-301 & 50-425/98-301 on 980413-15.Exams Results:All Candidates Passed Tests Except for One SRO ML20216J6611998-04-0202 April 1998 Notice of Violation from Insp on 980125-0307.Violation Noted:On 980219,Unit 2 Shift Supervisor Authorized Maint on Control Room Emergency Filtration Sys Train B W/O Recognizing Work Would Render Train Inoperable IR 05000424/19980021998-04-0202 April 1998 Insp Repts 50-424/98-02 & 50-425/98-02 on 980125-0307. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering PNO-II-98-017, on 980320,female Contract Worker Found Unconscious at Bottom of man-lift Station in Turbine Bldg. Plant First Aid Team Responded & Ambulance Was Called. Injured Person Transported to Hosp & Pronounced Dead1998-03-20020 March 1998 PNO-II-98-017:on 980320,female Contract Worker Found Unconscious at Bottom of man-lift Station in Turbine Bldg. Plant First Aid Team Responded & Ambulance Was Called. Injured Person Transported to Hosp & Pronounced Dead IR 05000424/19970121998-02-23023 February 1998 Insp Repts 50-424/97-12 & 50-425/97-12 on 971214-980124.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20198M3681998-01-12012 January 1998 Notice of Deviation from Insp on 971102-1213.Deviation Noted:Since Initial Startup of Both Units 1 & 2,licensee Failed to Perform 18-month Surveillance Testing on Reactor Coolant Pump 125V Direct Current non-1E Control Breakers ML20198M6861998-01-12012 January 1998 Insp Repts 50-424/97-11 & 50-425/97-11 on 971102-1213. Violations Noted.Major Areas Inspected:Operations & Maint ML20198M3401998-01-12012 January 1998 Notice of Violation from Insp on 971102-1213.Violation Noted:Since Initial Startup of Both Units 1 & 2,procedures 14420-1/2 & 14421-1/2 Inadequate ML20202E1971997-11-26026 November 1997 Notice of Violation from Insp on 970921-1101.Violation Noted:On 971003,10 Unit Heater Breakers on MCC 1NBG Were Found Open & Not Tagged IR 05000424/19970101997-11-26026 November 1997 Insp Repts 50-424/97-10 & 50-425/97-10 on 970921-1101. Violations Noted.Major Areas Inspected:Operations, Engineering,Maint & Plant Support IR 05000424/19970091997-10-20020 October 1997 Insp Repts 50-424/97-09 & 50-425/97-09 on 970803-0920. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering,Plant Support & Security & Safeguards Procedures & Documentation ML20212F3471997-10-20020 October 1997 Notice of Violation from Insp on 970803-0920.Violations noted:54 Fire Extinguishers W/Insp Sticker ,were Issued Between 970730 & 0815 & Did Not Meet Insp Criteria of Procedure 92020-C ML20211F2501997-09-15015 September 1997 SALP Repts 50-424/97-99 & 50-425/97-99 for Vogtle Electric Generating Plant for 960128-970802 ML20210S0601997-08-28028 August 1997 Insp Repts 50-424/97-07 & 50-425/97-07 on 970706-0802. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support ML20210S0551997-08-28028 August 1997 Notice of Violation from Insp on 970706-0802.Violation Noted:On 970708,during Maint on Shaft Seal in Unit 1 Personnel Airlock,Licensee Failed to Document Entry Into Appropriate Action Condition for TS LCO 3.6.2 ML20210N6731997-08-14014 August 1997 Insp Repts 50-424/97-08 & 50-425/97-08 on 970623-27. Deviations Noted.Major Areas Inspected:Qa in Operations, Maint,Engineering & Health Physics ML20210N6521997-08-14014 August 1997 Notice of Deviation from Insp on 970623-27.Deviation Noted: Incidents or Events Associated W/Ufsar Section 17.2.1.1.1.F & H Were Not Reviewed on 961218 & 970430 Srb Meetings ML20198F8631997-08-0404 August 1997 Insp Repts 50-424/97-06 & 50-425/97-06 on 970601-0705. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20198F8551997-08-0404 August 1997 Notice of Violation from Insp on 970601-0705.Violation Noted:Six Individuals Reported for Duty to ERFs & Failed to Complete sign-in Sheets on 970527,during Performance of Recall Emergency Drill ML20141F6971997-06-24024 June 1997 Notice of Violation from Insp on 970427-0531.Violation Noted:Time Between Performances of Procedure 29100-C,for Visual Insp of Fire Extinguishers & Fire Hose Stations, Exceeded 31 Days ML20141F7031997-06-24024 June 1997 Insp Repts 50-424/97-05 & 50-425/97-05 on 970427-0531. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support Re Scenario for off-hour Emergency Response Drill ML20140B4071997-05-21021 May 1997 Insp Repts 50-424/97-04 & 50-425/97-04 on 970316-0426. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support & Emergency Preparedness Area ML20140B3951997-05-21021 May 1997 Notice of Violation from Insp on 970316-0426.Violation Noted:Between 970329 & 0404,numerous Examples of Unattended & Unevaluated Debris Have Been Identified & Eight EPIP Revs Had Not Been Distributed ML20138J4161997-04-25025 April 1997 Notice of Violation from Insp on 970210-0307.Violation Noted:Licensee Offered for Transportation by exclusive-use, Closed Transport Vehicle,Package Which Arrived Having Max Surface Radiation Levels Exceeding 10 Msv/Hr ML20137X3751997-04-14014 April 1997 Notice of Violation from Insp on 970202-0315.Violation Noted:Positions of Valves 2-1302-U4-180 - 185 Not Verified Every 31 Days as Required ML20137X3811997-04-14014 April 1997 Integrated Insp Repts 50-424/97-01 & 50-425/97-01 on 970202- 0315.Violations Noted.Major Areas Inspected:Operations, Maint,Engineering & Plant Support 1999-08-16 |
_
December 20, 1985 l -PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE PN0-II-85-120 This preliminary notification constitutes EARLY notice of events of POSSIBLE safety or public interest significance. The information is as initially received without verifi-cation or evaluation, and is basically all that is known by the Region II staff on this data.
FACILITY: Georgia Power Company Licensee Emergency Classification:
Vogtle Unit 1 Notification of Unusual Event Docket No. 50-424 Alert Waynesboro, Georgia - Site Area Emergency General Emergency X Not Applicable
SUBJECT:
MEDIA INTEREST IN CONTAINMENT EVACUATION Tha NRC Resident Inspector informed Region II today that area media interest has developed in two events which occurred on November 19 and December 17 when a concentrated i hydrazine/ ammonia mixture leaked from a steam generator vent valve, forcing evacuation of personnel in the containment area.
Tha plant is under construction, and the event posed no nuclear safety problem. However, several employees complained of chest pains after breathing the fumes, and one person was briefly hospitalized with breathing difficulties, treated and released following the November 19 event. No adverse effects on personnel were reported following the December 17 occurrence.
The licensee is responding to media inquiries.
The Occupational Safety & Health Administration (OSHA) has been notified.
This PN is being issued for information purposes only.
This information is current as of 11:00 a.m. (EST) on December 20.
Contact:
M. Sinkule, 242-5506 V. Brownlee, 242-5583 i DISTRIBUTION:
H. Street MNBB Phillips E/W Willste MAIL:
Chairman Palladino IDT NRR T NMSS ADNiLh8 Comm. Roberts PA OIA RES D0T: Trans Only Comm. Asselstine MPA AE00 Applicable State Comm. Bernthal ELD Comm. Zech Air Rights INP0 2 %
CA
'PDR Regions: f: 2 :20 .2H' J .'d , 2-3 M')
3 1
Licensee: 2:n (Reactor Licensees) l Applicable Resident Site 2. *. W
~
O g22g74e51220 [