ML20080Q596

From kanterella
Jump to navigation Jump to search
Part 21 Rept Re Cracks in Limitorque Limit Switch Molded Components.Cracks Initially Limited to Component Surface. Recently Discovered Deeper Cracks Could Affect Component Integrity.Affected Components Should Be Replaced
ML20080Q596
Person / Time
Site: Callaway Ameren icon.png
Issue date: 02/21/1984
From: Denham F
LIMITORQUE CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
REF-PT21-84-128-000 PT21-84-128, PT21-84-128-000, NUDOCS 8402240127
Download: ML20080Q596 (3)


Text

.

LIMITORQUE CORPORATION g%,j"j;a t f 5114 Woodall Road P. O. Box 11318 Lynchburg, Virginia 24506 L_ w Telephone-804-528-4400 Telex--82-9448 February 21, 1984 g

.A /

,l O ',

!?

Office of the Director Ncclear Regulatory Commission Inspection & Enforcement Washington DC 20555

Subject:

Limitorque Advisory Gentlemen:

A recent experience at the Union Electric Company, Callaway Nuclear Station, has prompted an evaluation by our Design Review Committee.

It was judged that, although a design deficiency is not involved, the possi-bility of similar situations arising in the nuclear industry would suggest a 10CFR (Part 21) advisory might be appropriate from the standpoint of mainte-nance and on-going equipment inspection by the various utilities.

We enclose a copy of our letter February 15, 1984, to the Westinghouse Electric Corporation which contains full detail on this situation along with our evalu-ation and recommendations.

Yours very truly, LIMITORQUE CORPORATION

,, d. m-F. K. Denham Executive Vice President FKD:dr l enc.

l 8402240127 840221 PDR ADOCK 05000483 l S PDR I I Automated Valve Actuators and Jacks for Industry

. s.

~

LIMITORQUE CORPORATION i, g

2%r i 5114 Woodan Road - P. O. Box 11318 Lynchburg, Virginia 24506 i Te!ephone-804-528-4400 Telex-82-9448

. February 13, 1984 Ucstinghouse Electric Corporation Electre Mechanical Division Cheswick Avenue Cheswick, PA 15024 Attention: Mr. Rudy Mrozoski Gentlemen: -

Subject:

Limitorque Limit Switch Rotors Over the past three years we have had sporadic reports of surface cracks on our white color limit switch molded components.

In each case, we requested that samples be returned to us for analysis. Our investigation concluded in every instance that these were surface cracks resulting from post mold shrinkage, cosmetic in nature and having no effect on the integrity of the part.

Recently, we have had another report from Union Electric Company, Callaway Station, of white limit switch rotors having cracks. Two samples were returned to us from the Callaway site. The components were subjected to a material analysis and also found to be in con-formance with the material specifications. These cracks very defi-nitely had a greater depth than the surface cracks which we have investigated previously and could possibly effect the integrity of the component.

In examining the samples to determine the crack depth, we found that it required several sharp blows to break the molding. Although the limit switch rotor is not a load bearing component, piping vibration or normal in-service shock might possibly cause a similar significantly cracked rotor to break and impair its ability to function. It should be noted that the more severe cracks observed in the Calloway samples may have resulted from rough handling during shipment and installation.

In summary, these are the first cracked white limit switch moldings that we have examined which cannot be classified as cosmetic.

The extent of these cracks cannot be determined by a visual examination, consequently, the component must be destroyed to determine the crack Automated Valve Actuators and Jacks for industry

P

. . .l as

~

.. LIMITORQUE CORPORATION Sheet N1 2

? .

Westinghouse Electric Corp.

Mr. Rudy '4rozoski February 15, 1984 depth. It is our recommendation that any white limit switch components which are found with cracks should be replaced as we are unaware of any non-destructive procedure that would differen-tiate between a harmless shrinkage crack and a crack that could impair operation.

Our current standard rotor for inside containment service is made of a brown material. In 1979, the white material was replaced by the-brown compound because the white material was no longer available from the supplier. The brown retors are directly inter-changeable with the white components and there have not been any reports of cracking in the brown material.

Replacement parts of'the current design (brown color material) can be purchased from Limitorque Corporation.

Very truly yours, LIMITORQUE CORPORATION b O- bt)

Daniel S. Warsing Technical Manager fic

_