Final Significant Deficiency Rept SDR 84-05 Re Potential for Valve Operator Motor Pinion Gear Key Failure Due to Improper Matls in Certain Limitorque Motor Operators.Initially Reported on 840418.All Affected Gear Keys Replaced
ML20084Q391
Person / Time
Site: Wolf Creek, Callaway, 05000000
Issue date: 05/09/1984
From: Seiken S
STANDARDIZED NUCLEAR UNIT POWER PLANT SYSTEM
To: Jay Collins, James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III), NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
SDR-84-05, SDR-84-5, SLNRC-84-078, SLNRC-84-78, NUDOCS 8405210238
Download: ML20084Q391 (2)


Text

n 7

5 e

SNUPPS Standardized Nuclear Unit Power Plant System 5 Choke Cherry Road Rockvitse, Maryland 20850 (301)869 8010 May 9, 1984 SLNRC 84- 078 FILE: 0491.10.2 SUBJ: Final Significant Deficiency Report (SDR 84-05): Limitorque Operators

- Sheared Motor Pinion Keys Mr. James G. Keppler Regional Administrator, Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 Mr. John T. Collins Regional Administrator, Region-IV U.S. Nuclear Regulatory Coirmssion Suite 1000, Parkway Central Plaza Arlington, Texas 76012 Docket Nos. STN 50-482 and STN 50-483

Reference:

IE Information Notice 81-08, March 20,1981: Motor-to-Shaft Keys in Limitorque Model SMB-4 Operators Gentlemen:

IE Infonnation Notice 81-08 provided notification of the potential for valve operator motor pinion gear key failure due to improper materials in certain Limitorque motor operators.

Investigation by the SNUPPS Pro-ject revealed that the reported problem was potentially applicable to pinion gear keys in Limitorque Models SMB-3 and

-4, SB-3 and -4, and SBD-3 and -4 equipped with motors that de'elop 150 foot-pounds torque or greater, and to all Limitorque Model SMB-5. operators.

As followup to the Information Notice 81-08, it had been determined that 150 foot-pound torque Model SBD-3 operators are used generically in both SNUPPS units in conjunction with seven (7) safety-related NSSS valves supplied by Westinghouse Electromotive Division (WEMD).

In addition, six

'(6) 150 foot-pound torque Model SMB-4 operators aiid one Model SMB-5 oper-ator are used,in conjunction with nonsafety-related, balance of plant valves supplied by the Crane Company. These latter seven (7) operators are also used generically on the SNUPPS plants.

Q MAY 141984

I a

SLNRC 84 078 Page Two The supplier of the operators, Limitorque, indicated the inability to confirm from their records which of these operators, if any, contained pinion gear keys manufactured from the incorrect material.

Consequently, it was decided to_ replace the motor pinion gear keys in all affected operators at both SNUPPS plants with keys manufactured from the correct,

9. 4140 steel, material.

In the course of replacing the suspect keys in d

th WEMD valves at the SNUPPS Callaway plant, physical damage to motor pinion keys, pinion keyways, gear set screws, and motor shafts were observed in two operators.

Had the damage to these two operators gone uncorrected, the valves would not have been able to perform their intended safety functions.

Consequently, these damaged actuators are considered reportable to NRC pursuant to the requirements of 10CFR50.55(e). Since the potential' exists for inadequate materials in the remaining SDB-3 and SMB-4 and -5 operator units, this matter is being treated as a deficiency generic to the two SNUPPS plants.

[ Note: The two damaged Limitorque operators identified at Callaway were reported to NRC Region III by Union Electric Co. (J. Laux and S. Shepley) on April 18,1984.] No damage has been observed in the process of pinion gear key changeout for the seven (7) nonsafety-related operators at Callaway, nor in any of the fourteen (14) operators at Wolf Creek.

Replacement of all affected motor pinion

~

gear kcys and correction of any damaged components have been completed at Callaway and Wolf Creek.

This report should be considered the final report on this issue. The NRC will be notified should there be any significant developments concerning this Significant Deficiency Report.

Should further questions arise on this subject, please do not hesitate to contact the undersigned or Mr.

White of my Staff.

Very truly yours, s

S. J. Seiken QA Manager RPW/dck/14a5 cc:

D. F. Schnell UE G. L. Koester KGE D. T. McPhee KCPL W. S. Schum NRC/WC J. H. Neisler NRC/ CAL B. H. Little NRC/ CAL R. C. DeYoung NRC/IE: HQ J. E. Konklin NRC/IE: III Record 4.