I Commonwulth Edison LaSalle County Nuclear Station d
2601 N.21st Rd.
' Marseilles, Illinois 61341 Telephone 815/357 6761 February 8, 1994 Nuclear Regulatory Commission Region III Attn: Chief Reactor Support Programs Branch 9 Roosevelt Road Glen Ellyn, Illinois 60137
Dear Sir:
Enclosed is the Semi-annual Radioactive Effluent Report for July through December, 1993 for LaSalle County Nuclear Station, Docket Numbers 50-373 and 50-374.
Two copies of the report are provided for your use. Two copies will be forwarded to the Document Control Desk and one copy to the Resident Inspector.
Sincerely, D. J. Ray
/ Station Manager LaSalle County Station enclosure cc: Document Control Desk, U.S. NRC Illinois Department of Nuclear Safety American Nuclear Insurers B. P. I.
U.S. EPA Murray and Trettel, Inc.
Teledyne Isotopes Midwest Laboratory Chemistry Services (OPUS)
NRC Resident Inspector (LaSalle)
Nuclear Quality Programs Supt. (LaSalle)
Station Manager, Central File Illini State Park EP File: EPG-01-R09 280044 -
i 9403070080 931231 3 5 L3 ADOCK 0500
i l
1 1
l LASALLE COUNTY NUCLEAR POWER STATION i UNITS ONE AND TWO l DOCKET NUMBERS 50-373 AND 50-374 '
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1993)
GASEOUS EFFLUENTS-SUMMATION OF ALL RELEASES Estimated Third Fourth Total Quarter Quarter Error %
A. Fission and Activation Gases
- 1. Total release Ci 9.85E+02 5.85E+01 44
- 2. Average release rate for period uCi/sec 1.24E+02 7.36E+00 B. Iodines
- 1. Total iodine-131 Ci 7.71E-03 2.08E-03 33
- 2. Average release rate for period uC1/sec 9.70E-04 2.62E-04 C. Particulates
- 1. Particulates with T1/2 >8 days Ci 1.61E-02 6.22E-03 25
- 2. Average release rate for period uCi/sec 2.03E-03 7.82E-04
! 1. Total release Ci 3.70E+01 1.95E+01 20 i
- 2. Average release rate for period uC1/sec 4.65E+00 2.45E+00
"<" indicates activity of sample is less than LLD given in uci/ml 1
1 i
4 1 of 25 ZCADRAD/194
- _ _ _____ . - . _ _ . . ~ _ . _ _
j EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1993)
I GASEOUS EFFLUENTS-ELEVATED RELEASE Unit 1 and Unit 2 Continuous Mode Third Nuclides Released July August September Quarter
- 1. Fission Gases Ar-41 Ci <1.00E-06 <1.00E-06 <1.00E-06 <1.00E-06 Kr-85 Ci <1.00E-06 <1.00E-06 <1.00E-06 <1.00E-06 Kr-85m Ci 4.10E+00 <1.00E-06 <1.00E-06 4.10E+00 Kr-87 Ci <1.00E-06 <1.00E-06 <1.00E-06 <1.00E-06 Kr-88 Ci <1.00E-06 9.73E+02 7.86E+00 9.81E+02 Xe-133 Ci <1.00E-06 2.97E-04 6.54E-02 6.55E-02 Xe-133m Ci <1.00E-06 <1.00E-06 <1.00E-06 <1.00E-06 Xe-135 Ci- <1.00E-06 1.96E-04 2.62E-02 2.64E-02 Xe-135m Ci <1.00E-06 <1.00E-06 <1.00E-06 <1.00E-06 Xe-138 Ci <1.00E-06 <1.00E-06 <1.00E-06 <1.00E-06 Total for period Ci 4.10E+00 9.73E+02 7.86E+00 9.85E+02
- 2. Iodines '
I-131 Ci 2.64E-04 6.05E-04 1.51E-04 1.02E-03 I-132 Ci 4.84E-04 <1.00E-11 <1.00E-11 4.84E-04 I-133 Ci 3.96E-03 1.95E-03 3.01E-04 6.21E-03 I-134 Ci <1.00E-11 <1.00E-11 <1.00E-11 <1.00E-11 I-135 Ci <1.00E-11 <1.00E-11 <1.00E-11 <1.00E-11 Total for period ~ Ci 4.71E-03 2.51E-03 4.52E-04 7.71E-03 ,
- 3. Particulates Cr-51 Ci 1.10E-04 1.63E-03 <1.00E-11 1.74E-03 Mn-54 Ci 5.48E-05 <1.00E-11 2.82E-05 Co-58 8.30E-05 Ci <1.00E-11 <1.00E-11 6.70E-05 6.70E-05 Na-24 Ci 5.31E-03 6.04E-03 6.37E-04 Fe-59 1.20E-02 Ci <1.00E-11 <1.00E-11 <1.00E-11 <1.00E-11 i
Tc-99m Ci 3.00E-04 <1.00E-11 <1.00E-11 l Co-60 3.00E-04 Ci 1.83E-04 1.75E-04 3.13E-04 6.71E-04
[ Zn-65 Ci <1.00E-11 <1.00E-11 <1.00E-11 <1.00E-11
- Sr-89 (Estimate) Ci <1.00E-11 .<1.00E-11 <1.00E-11 <1.00E-11 l
Sr-90 (Estimate) Ci <1.00E-11 <1.00E-11 <1.00E-11 <1.00E-11 Nb-95 Ci <1.00E-11 <1.00E-11 <1.00E-11 Mo-99 <1.00E-11 Ci <1.00E-11 <1.00E-11 <1.00E-11 <1.00E-11 Cs-134 Ci <1.00E-11 <1.00E-11 <1.00E-11 Cs-137 <1.00E-11 Ci <1.00E-11 <1.00E-11 <1.00E-11 <1.00E-11 Cs-138 Ci <1.00E-11 <1.00E-11 <1.00E-11 Ba-139 <1.00E-11 C1 1.26E-03 <1.00E-11 <1.00E-11 1.26E-03 Ba-140 Ci <1.00E-11 <1.00E-11 <1.00E-11 La-140 <1.00E-11 Ci <1.00E-11 <1.00E-11 <1.00E-11 <1.00E-11 Ce-141 Ci <1.00E-11 <1.00E-11 <1.00E-11 Ce-144 <1.00E-11 Ci <1.00E-11 <1.00E-11 <1.00E-11 <1.00E-11 Total for period Ci 7.22E-03 7.85E-03 1.05E-03 1.61E-02
"<" indicates activity of sample is less than LLD given uci/nd l
2 of 25 ZCADRAD/194 L
t - , - , , - - - , - , . , . , - - . - - - . . . - - - . . .-
i .
i, .
i -
1 i EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1993)
GASEOUS EFFLUENTS-ELEVATED RELEASE Unit 1 and Unit 2 Continuous Mode i I
l 1
Fourth Nuclides Released October November December Quarter 1
1
- 1. Fission Gases i
Ar-41 Ci <1.00E-06 <1.00E-06 <1.00E-06 <1.00E-06 Kr-85 Ci <i.00E-06 <1.00E-06 <1.00E-06 <1.00E-06 Kr-85m Ci <1.00L-06 <1.00E-06 3.24E+00 3.24E+00 Kr-87 Ci 5.05E+00 <1.00E-06 1.54E+01 2.05E+01 Kr-88 Ci 7.13E+00 8.10E+00 1.77E+01 3.29E+01 Xe-133 Ci 2.30E-04 <1.00E-06 6.98E-04 9.28E-04 Xe-133m Ci <l.00E-06 <1.00E-06 <1.00E-06 <1.00E-06 Xe-135 Ci 1.85E+00 <1.00E-06 2.92E-04 1.85E+00 i Xe-135m Ci <1.00E-06 <1.00E-06 <1.00E-06 <1.00E-06 Xe-138 Ci <1.00E-06 <1.00E-06' <1.00E-06 <1.00E-06 Total for period Ci 1.40E+01' 8.10E+00 9.63E+01 5.85E+01
- 2. Iodines I-131 Ci <1.00E-11 5.14E-05 <1.00E-11 5.14E-05 I-132 Ci <1.00E-11 <1.00E-11 <1.00E-11 <1.00E-11 I-133 Ci 1.92E-04 1.26E-04 5.76E-04 2.03E-03 I-134 Ci <1.00E-11 <1.00E-11 <1.00E-11 <l.00E-11 I-135 Ci <1.00E-11 <1.00E-11 <1.00E-11 <1.00E-11 Total for period C1 1.92E-04 1.77E-04 5.76E-04 2.08E-03
- 3. Particulates Cr-51 Ci <1.00E-11 1.30E-04 <1.00E-11 1.30E-04 Mn-54 Ci 4.59E-07 <1.00E-11 <1.00E-11 Na-24 4.59E-07 Ci 7.44E-04 2.45E-03 7.93E-04 3.99E-03 Co-58 Ci <1.00E-11 <1.00E-11 <1.00E-11 Fe-59 <1.00E-11 Ci <1.CCE-li s1 00E-11 <1.00E-11 <1.00E-11 Tc-99m Ci <1.00E-11 6. 9 '.E-04 1.82E-04 Co-60 8.73E-04 Ci 6.95E-05 1.9bE-04 1.71E-04 4.38E-04 Zn-65 Ci <1.00E-11 <l.00E-11 <1.00E-11 <1.00E-11 Sr-89 (Estimate) Ci <1.00E-11 <1.00E-11 <1.00E-11 <1.00E-13 Sr-90 (Estimate) Ci <1.00E-11 <1.00E-11 <1.00E-11 <1.00E-ll Nb-95 Ci <1.00E-11 <1.00E-11 <1.00E-11 Mo-99 <1.00E-11 Ci <1.00E-11 <l.00E-11 <1.00E-11 <1.00E-11 Cs-134 Ci <1.00E-11 <1.00E-11 <1.00E-11 Cs-137 <1.00E-11 Ci <1.00E-11 <1.00E-11 <1.00E-11 <1.00E-11 Cs-138 Ci <1.00E-11 <1.00E-11 <1.00E-11 l
Ba-139 Ci
<1.00E-11
<1.00E-11 <1.00E-11 7.92E-04 7.92E-04 Ba-140 Ci <1.00E-11 <1.00E-ll <1.00E-11 La-140 Ci
<1.00E-11
<1.00E-11 <1.00E-11 <1.00E-11 <1.00E-11 l Ce-141 Ci <1.00E-11 <l.00E-11 <1.00E-11 Ce-144 <1.00E-11 C1 <1.00E-11 <1.00E-11 <1.00E-11 <1.00E-11 Total for period Ci 8.14E-04 4.64E-03 1.94E-03 6.22E-03
"<" indicates activity of sample is less than LLD given uci/ml 3 of 25 ZCADRAD/194
. , . _ .- - - . . . - - . _- . ~ . - - - - - . __ _ . - _ . - . . , - .
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1993)
UNIT ONE LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES Third Fourth Quarter Quarter-A. Fission and Activation Products
- 1. Total release (not including Ci 0.00E+00 0.00E+00 tritium, gases, alpha)
- 2. Average concentration releraed uCi/ml N/A N/A
- 3. Maximum concentration released uCi/ml N/A N/A B. Tritium
- 1. Total release Ci 0.00E+00 0.00E+00
- 2. Average concentration released uCi/ml N/A N/A C. Dissolved Noble Gases
- 1. Total release 0.00E+00 2.
ci 0.00E+00 Average concentration released uCi/ml N/A N/A D. Gross Alpha Radioactivity
- 1. Total release 0.00E+00
- 2. Average concentration releared C1 0.00E+00 uCi/ml N/A N/A E. Volume of Waste Released (prior to dilution) liters 0.00E+00 0.00E+00 F. Volume of Dilution Water liters- 0.00E+00 0.00E+00
"<" indicates activity of sample is less than LLD given in uCi/ml 4 of 25 ZCADRAD/194
.-..__.m.. . _ . _ . . . _ . . . . . _ _ . . _ . . . _ . . _ . . . _ . . . . _ _ _ . . _ _ . . _ ~ _ _ . _ _ . _ _ . _ _ _ _ _ _ . _ _ .
l-I EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1993)
UNIT ONE BATCH MODE LIQUID EFFLUENTS Third Nuclides Released July August September Quarter Cr-51 Ci Mn-54 Ci No No No No Fe-55 Ci Releases Releases Releases Releases co-58 Ci Fe-59 C1 Co-60 Ci Zn-65 Ci Sr-89 Ci Sr-90 Ci Nb Ci Zr-95 Ci Mo-99 Ci Tc-99m Ci I-131 Ci Cs-134 Ci Cs-137 Ci Ba-140 Ci La-140 Ci Ce-141 Ci Ce-144 Ci Total for period C .. 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Xe-131m Ci Xe-133m Ci Xe-133 Ci Xe-135m Ci Xe-135 Ci ,
"<" indicates activity of sample is less than LLD given in uCi/ml l
l I
5 of 25 ZCADRAD/194
I
( .
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1993)
UNIT ONE BATCH MODE LIQUID EFFLUENTS 1
Fourth l Nuclides Released October November December Quarter {
Cr-51 Ci No No No No Mn-54 Ci Releases Releases Releases Releases Fe-55 Ci Co-58 Ci Fe-59 C1 Co-60 Ci I
Zn-65 Ci Sr-89' Ci Sr-90 Ci Nb-95 Ci Zr-95 Ci ;
Mo-99 Ci Tc-99m Ci I-131 C1 Cs-134 C1 Cs-137 Ci Ba-140 Ci La-140 Ci Ce-141 Ci Ce-144 Ci Total for period Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 l
Xe-131m Ci Xe-133m Ci Xe-133 Ci Xe-135m Ci Xe-135 Ci
"<" indicates activity of sample is less than LLD given in uci/ml i
i I
6 of 25 ZCADRAD/194
I f* EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1993)
UNIT TWO 1
LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES Third Fourth Quarter Quarter l A. Fission and Activation Products I 1. Total release (not including Ci 0.00E+00 0.00E+00 tritium, gases, alpha)
- 2. Average concentration released uCi/ml N/A N/A
- 3. Maximum concentration released uCi/nd N/A N/A B. Tritium
- 1. Total release ci 0.00E+00 0.00E+00
- 2. Average concentration released uCi/ml N/A N/A C. Dissolved Noble Gases
- 1. Total release Ci 0.00E+00 0.00E+00
- 2. Average concentration released uC1/nd N/A N/A D. Gross Alpha Radioactivity
- 1. Total release Ci 0.00E+00 0.00E+00 t 2. Average concentration released uCi/ml N/A N/A l
E. Volume of Waste Released liters 0.00E+00 0.00E+00 F. Volume of Dilution Water liters 0.00E+00 0.00E+00
"<" indicates activity of sample is less.than LLD given in uCi/ml l
l l
I 1
\
l \
l l
l l
l ;
I I I
l 7 of 25 ZCADRAD/194
.i
)
. l I
i I
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1993) l UNIT TWO BATCH MODE I ;
LIQUID EFFLUENTS ;
Third Nuclides Released July August September Quarter ,
Cr-51 Ci Mn-54 Ci No No No No Fe-55 Ci Releases Releases Releases Releases Co-58 Ci Fe-59 C1 Co-60 Ci Zn-65 Ci Sr-89 Ci Sr-90 Ci Nb-95 Ci l Zr-95 Ci
, Mo-99 Ci Tc-99m Ci I-131 C1 Cs-134 Ci Cs-137 Ci Ba-140 Ci La-140 Ci Ce-141 C1 Ce-144 Ci Total for period Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Xe-131m Ci Xe-133m Ci Xe-133 Ci Xe-135m Ci Xe-135 Ci s
"<" indicates activity of sample is less than LLD given in uCi/ml i
i l
l l
l l
l I
I l
l 8 of 25 ZCADRAD/194 l l
~ . - . . . . . . - .- .
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1993)
UNIT TWO BATCH MODE LIQUID EFFLUENTS Fourth Nuclides Released October November December Quarter
.Cr-51 Ci No No No No Mn-54 Ci Releases Releases Releases Releases l Fe-55 Ci Co-58 Ci Fe-59 Ci Co-60 Ci Zn-65 Ci l Sr-89 Ci Sr-90 Ci Nb-95 Ci l Zr-95 Ci
! Mo-99 Ci Tc-99m Ci I-131 Ci Cs-134- Ci Cs-137 Ci Ba-140 C1 La-140 1
Ci
! Ce-141 Ci l l Ce-144 Ci
! Total for period Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Xe-131m Ci l
Xe-133m Ci Xe-133 Ci Xe-135m Ci Xe-135 Ci
! "<" indicates activity of sample is less than LLD given in uCi/ml I
9 of 25 ZCADRAD/194 l
j i .
4 EFFLUENT AND WASTE DISPOSAL SD4I-ANNUAL REPORT (1993) l MAXIMUM DOSES RESULTING FROM RELEASES a
l Third Fourth {
j Quarter- Quarter 2
A. Gaseous Effluents (Units One and Two) 1 1. Gamma air mrad 4.28E-02 1.78E-03 l 2. Beta air mrad 7.05E-04 7.56E-05 l
! 3. Total body mrem 2.91E-02 1.21E-03 '
- 4. Skin mrem 3.37E-02 1.43E-03 j 5. Organ (infant thyroid) mrem 6.22E-03 2.00E-03 i
I B. Liquid Effluents (Unit One) i 1. Total body mrem 0.00E+00 0.00E+00
- 4. Internal organ (adult liver) mrem 0.00E+00 0.00E+00 l C. Liquid Effluents (Unit Two) i
! 1. Total body mrem 0.00E+00 0.00E+00
- 4. Internal organ mrem 0.00E+00 0.00E+00 ;
COMPLIANCE STATUS A. Gaseous Effluents (Units One and Two)
- 1. Gamma air % of Tech. Spec. Limit 0.86 0.04
- 2. Beta air % of Tech. Spec. Limit 0.01 0.00
- 3. Total body % of Tech. Spec. Limit 1.16 0.05
- 4. Skin % of Tech. Spec. Limit 0.45 0.02
- 5. Organ % of Tech. Spec. Limit 0.08 0.03 B. Liquid Effluents (Unit One)
- 1. Total body % of Tech. Spec. Limit 0.00
- 2. 0.00 Internal organ % of Tech. Spec. Limit 0.00 0.00 f
C. Liquid Effluents (Unit Two) 4
- 1. Total body % of Tech. Spec. Limit 0.00
- 2. 0.00 i Internal organ (adult liver) % of Tech. Spec. Limit 0.00 0.00 l I
ZCADRAD/194 l
. , . . . _ . . _ , - - _ m
. - _ . . . - .. . .- - - - . . . . . __ _ . _ = - . -. _ _ __ _ ..
1 1
l
! I l .
' ]
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1993)
SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL Third 1 July August September Quarter i 1. Spent resins, filter sludges,
- evaporator bottoms, etc.
1
] a. Quantity. shipped cu.m. 1.45E+01 3.08E+01 2.31E+01 6.84E+01 f b. Total activity Ci 1.54E+01 2.35E+02' 2.47E+02 4.97E+02
! c. Major nuclides (estimate)
- Mn-54 % 5.4 4 7
- Fe-55 % 72 79 75
- Co-58 % 0.31 0.35 1
?
Co-60 % 19 13 16
]
j e. Container volume cu.m. 4.83E+00 3.088+01 5.82E+00 i 5.82E+00 4.33E+00
, f. Solidification agent Cement Cement Cement
- 2. Dry compressible waste, contaminated equipment, etc.
- a. Quantity shipped cu.m. 0.00E+00 '7.24E+01 0.00E+00 7.24E+01
- b. Total activity Ci 0.00E+00 1.21E+00 0.00E+00 1.21E+00
- c. Major nuclides (estimate)
Cr-51 % 0 8 0 Mn-54 % 0 28 0 i
Fe-55 % 0 22 0 Fe-59 % 0 13 0 Co-60 % 0 0 0
- d. Container type N/A LSA N/A
- e. Container volume cu.m. N/A 7.24E+01 N/A )
1 1
1 i
i I
i I
1 i
i 11 of 15 ZCADRAD/194
_ _ - _ - - _ _ _ - _ _ - - _ - _ . _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _- +P--=r ,n- +- C T'
. .- - . - - . - . . . . . . . ~ . - -
1 k . .
- . i l
! l j
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1993) i 1 SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL 1
Third July August September Quarter-
- 3. Other
- a. Quantity shipped cu.m. 0.00E+00. 0.00E+00 0.00E+00 0.00E+00
- b. Total activity Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- c. Major nuclides (estimate).
Cr-51 % 0 0 0 Mn-54 % 0 0 0 Fe-55 .% 0 0 0' Fe-59 % 0 0 0 co-60 % 0 0 0
- d. Container type N/A N/A N/A
- e. Container volume cu.m. N/A N/A N/A
- 4. Irradiated Components
- a. Number of shipments 1 0 0 1-
- b. Mode of Transportation Truck N/A N/A'
- c. Destination Barnwell N/A N/A
- 5. Solid Waste Pisposition
- a. Number o' 9hipments 3 8 5 16
- b. Mode of Tran:portation' Truck Truck . Truck Number 3 8 5
- c. Destination ,
Oak Ridge, TN Oak Ridge, TN Oak Ridge, TN Numi.er 0 1 'O Barnwull, SCBarnwell, SCBarnwell, SC Number 3 7 5 12 of 25 ZCADRAD/194
e 1
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT . (1993) l l
SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL l
Fourta October hovember December ,Otta r t er
- 1. Spent resins, filter sludges, i evaporator bottoms, etc.
- a. Quantity shipped cu.m. 2.03E+01 1.88E+01 1.30E+01 5.21E+01
- b. Total activity Ci 7.80E+01 2.53E+02 2.38E+02 5.69E+02
- c. Major nuclides Mn-54 % 4 7 6 Fe-55 % 81 75 72 Co-58 % 0 0.08 0 Co-60 % 14 16 19 Ni-63 % 0.5 1 0.4
- e. Container volume cu.m. 4.33E+00 4.33E+00 4.33E+00 5.82E+00 5.82E+00 I
- f. Solidification agent Cement Cement Cement 1
- 2. Dry compressible waste, contaminated equipment, etc.
- a. Quantity shipped cu.m. 1.45E+00 7.66E+01 8.18E+01 1.60E+02
- b. Total activity Ci 2.38E+01 8.04E-01 1.36E-01 2.47E+01
- c. Major nuclides (estimate)
Cr-51 % 7 8 8 Mn-54 % 28 28 28 Fe-55 % 23 22 22 Fe-59 % 12 12 0 Co-60 % 28 27 27 i
i
- e. Container volume cu.m. 7.24E+01 4.33E+00 7.24E+01 9.34E+00 l
l 13 of 25 ZCADRAD/194
j g . .
3 .
- EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1993) j SOLID WASTE SHIPPED OFFSITE FOR BURIAL.OR DISPOSAL i
j Fourth October November December Quarter y 3. Other
] a. Quantity shipped cu.m. 0.00E+00 0.00E+00 3.41E+00 3.41E+00 l
- b. Total activity C1 0.00E+00 0.00E+00 1.64E+02 1.64E+02 1
, c. Major nuclides (estimate) l Cr-51 % 0 0 8
- Mn-54
' % 0 0 28 Fe-55 % 0 0 22 i Fe-59 % 0 0 13 l Co-60 % 0 0 27 j d. Container type N/A N/A LSA J
l e. Container volume cu.m. N/A N/A 3.41E+00 4
] 4. Irradiated Components
- a. Number of shipments 0 0 0
! b. Mode of Transportation N/A. N/A N/A i
- c. Destination N/A N/A N/A i
j
- 5. Solid Waste Disposition i
3 a. Number of Shipments 6 6 6 18
- b. Mode of Transportation Truck Truck Truck Number 6 6 6 J
- c. Destination j Oak Ridge, TN Oak Ridge, TN Oak Ridge, TN Number 2 1 2
! i 1
i Barnwell, SC Barnwell, SC Barnwell, SC 4
Number 4 5 4 4
k l i 1 !
2 d
- l 1
1 i
i 3 ;
a i
1 I
14 of 25 i 1
ZCADRAD/194
'a .
l EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1993)
Supplemental Information
- 1. Regulatory Limits
- a. Gaseous Effluents
- 1) The air dose due to noble gases released in gaseous ef fluents, from each reactor unit, from the site shall be limited to the following:
a) During any calendar quarter: Less than or equal to 5 mrad for gamma radiation and less than or equal to 10 mrad for beta radiation, and b) During any calendar year: Less than or equal to 10 mrad for gamma radiation and less than or equal to 20 mrad for beta radiation.
- 2) The dose to an individual from radiolodines and radioactive materials in particulate form, and radionuclides, other than noblo gases, with half-lives greater than eight days in gaseous effluents released, from each reactor unit, from the site shall be limited to the following:
a) During any calendar quarter: Less than or equal to 7.5 mRems to any organ, and b) During any calendar year: Less than or equal to 15 mRems to any organ,
- b. Liquid Effluents
- 1) The dose or dose commitment to an individual from radioactive materials in liquid effluents released, from each reactor unit, from the site shall be limited:
a) During any calendar quarter to less than or equal to 1.5 mrem to the total body and to less than or equal to 5 mrem to any organ, and b) During any calendar year to less than or equal to 3 mrem to the total body and to less than or equal to 10 mrem to any organ,
- c. Total Dose
- 1) The dose or dose commitment to any member of the public, due to releases or radioactivity and radiation, from uranium fuel cycle sources shall be lim ted to less than or equal to 25 mrem to the body or any organ (except the thyroid, which shall be limited to less than or equal to 75 mrem) over 12 l consecutive months, l
1 l
15 of 25 ZCADRAD/194 i i
.-,.._. - - - - - --- . . . . - - . - - . , - - . - . . . . . - -1
]
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1993)
Supplemental Information (continued) r
- 2. Maximum Permissible Concentrations t
l a. Gaseous Effluents i
- 1) The dose rate due to radioactive materials released in gaseous effluents from the site shall be limited to the following:
a) For noble gases: Less than or equal to 500 mrem / year to '
the total body and less than or equal to 3000 mrem / year to the skin, and b) For all radioiodines and for all radioactive materials in particulate form, and radionuclides, other than noble gases, with half-lives greater than eight days: Less than or equal to 1500 mrem / year to any organ via the inhalation pathway.
- b. Liquid Effluents
- 1) The concentration of radioactive material released form the site shall be limited to the concentrations specified in 10 CFR Part 20, Appendix B, Table II, Column 2 for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to the following:
Nuclide MPC (pci/ml)
Kr-85m 2.00E-04 Kr-85 5.00E-04 Kr-87 4.00E-05 Kr-88 9.00E-05
' Ar-41 7.00E-05 Xe-131m '7.00E-04 Xe-133m 5.00E-04
' Xe-133 6.00E-04 Xe-135m 2.00E-04 Xe-135 2.00E-04
- 3. Average Energy
- a. Not Applicable.
- 4. Measureme is and Approximations of Total Radioactivity
- a. Gaseous Effluents
- 1) Containment Vent and Purge System is sampled by grab sample which is analyzed for principal gamma emitters and H-3.
- 2) Main Vent Stack is sampled by grab sample which is analyzed for principal gamma emitters and H-3.
- 3) Standby Gas Treatment System is sampled by grab sample which is analyzed for principal gamma emitters.
16 of 25 ZCADRAD/194
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1993)
Supplemental Information (continued)
- 4) All release types as listed in 1 and 2 above, at the vent stack and as listed in 3 above, at the Standby Gas Treatment System whenever there is a flow, are continuously sampled by charcoal, particulate and composite samples which are analyzed for iodines, principal gamma emitters, gross alpha, Sr-89 and Sr-90. Noble gases, gross beta and gamma are continuously monitored by noble gas monitors for the vent stack and the-standby gas treatment system.
- b. Liquid Effluents
- 1) Batch waste release tanks are sampled each batch for principal gamma emitters, I-131, dissolved and entrained noble gases, H-3, gross alpha, Sr-89, Sr-90 and Fe-55,
- 2) continuous releases are sampled continuously in proportion to the rate of flow of the effluent stream and by grab sample.
Samples are analyzed for principal gamma - emitters, I-131, dissolved and entrained noble gases, H-3, gross alpha, Sr-89, Sr-90 and Fe-55.
- 5. Batch Releases I
- a. Gaseous ,
i
- 1) Number of batch releases: None t
- 2) Total time period for batch releases: N/A
- 3) Maximum time period for a batch release: N/A
- 4) Average time period for batch releases: N/A
- 5) Minimum time period for a batch release: N/A
- b. Liquid
- 1) Number of batch releases: N/A
- 2) Total time period for batch releases: N/A
- 3) Maximum time period for a batch release: N/A
- 4) Average time period for batch releases: N/A
- 5) Minimum time period for a batch release: N/A
- 6) Average stream flow during periods of release of effluent into a flowing stream: N/A l
17 of 25 ZCADRAD/194
~ . - - - - . - . . . _ . . . . . . . - _ - .. . . . . .- .
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1993)
Supplemental Information (continued) l
- 6. Abnormal Releases '
- a. Gaseous
- 1) Number of releases: None
- 2) Total activity released: N/A
- b. Liquid
- 1) Number of releases: None
- 2) Total activity released: N/A i
18 of 25 ZCADRAD/194 l
l, , . , _ _ , . _ ..
l EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1993)
METEOROLOGICAL DATA I
l l
(See following pages.)
I l
l I
l s
i l
19 of 25 ZCADRAD/194 l 1
a
I -
CECoLASALLESTATIOX hly-September 1993 375ft.V!XDSPEEDandVINDDICECTION 375-33ft.DIFFEDEti[ALTEMPERATURE XUW8EROFOBSERVATIONS: 2187 VALUESAREPER0ENTOCCURRENCE SPEED WINDDIRECTIONCLASSES--- - - - - - - - - - - - - - -
STA8IlliYCLASSES- ----
CLASS X HE XE EXE E ESE SE SSE S SSV St VSt W m H HV TOTAL EU H SU R $$ NS ES TOTAL EU .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 W .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 l C SU .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 ,00 .00 .00 .00
' AR .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .C0 .00 .00 .00 .00 .00 .00 L SS .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 NNS .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 ES .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00
.00 EU .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 H .00 .00 .00 .00 .00 .00 .00 .00 .00 .05 .00 .00 .00 .00 .00 .00 .05 .05 1 SU .05 .00 .00 .00 .05 ,00 .00 .09 .05 .00 .09 .00 .00 .00 .00 .00 .27 .21
-X .14 .05 .09 .09 .09 .05 .09 .09 .05 .05 .05 .00 .09 .14 .05 .14 1.23 1.23 l
3$$ .05 .00 .05 .05 .05 .05 .14 .00 .00 .00 .00 .00 .09 .05 .05 .00 .55 .55 NS .00 .00 .05 .05 .00 .00 .14 .05 .00 .05 .00 .09 .05 .00 .00 .00 .46 .46 ES .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 2.56 EU 00 .00 .05 .00 .05 .00 .00 .05 .05 .00 .00 .00 .00 .00 .00 .00 .18 .18 H .00 .09 .23 .00 .00 .00 .09 .14 .23 .09 .00 .00 .00 .00 .00 .05 .91 .91 4 SU .05 .05 .14 .05 .09 .00 .18 .09 .05 .14 .09 .09 .05 .14 .14 .00 1.33 1.33
-N .91 .64 .55 .69 .64 .59 .91 .2T .18 .00 .23 .18 .41 .46 .50 .27 f.45 1.45 iSS .14 .18 .59 .23 .27 .41 .14 .09 .05 .14 .09 .05 .00 .05 .09 .14 2.65 2.65 NS .00 .00 .00 .09 .14 .18 .23 .32 .21 .27 .23 .09 .23 .14 .00 .05 2.24 2.24 ES .00 .00 .00 .00 .00 .00 .09 .05 .00 .00 .09 .05 .00 .05 .05 .05 .41 .41 15.18 EU .00 .00 .00 .00 .00 .00 .00 .14 .09 .41 .05 .00 .00 .00 .00 .00 .69 .69 H .00 .23 .00 .00 .05 .00 .05 .14 .41 .32 .32 .00 .00 .00 .00 .09 1.60 1.60 8 SU .32 .05 .00 .00 .00 .09 .14 .05 .18 .09 .32 .18 .14 .23 .41 .37 2.56 2.56
- R 1.05 1.10 .41 .59 .73 1.10 1.42 .32 .46 .46 .55 .50 .37 .78 .73 .41 10.97 10.97 1SS .18 .46 .46 .23 .46 .46 .55 .32 .23 .50 .31 .41 .59 .59 .14 .18 6.13 6.13 2NS .05 .00 .05 .09 .05 .14 .32 .23 .23 .27 .37 .09 .14 .14 .18 .31 2.10 2.10 ES .00 .00 .00 .00 .00 .00 .00 .00 .09 .18 .09 .05 .00 .05 .00 .09 .55 .55 25.19 EU .00 .00 .00 .00 .00 .00 .00 .05 .00 .00 .00 .00 .00 .00 .00 .00 .05 .05 l 10 .05 .05 .00 .00 .00 .00 .05 .05 .27 .50 .18 .05 .00 .00 .00 .05 1.23 1.23 .
3 Sl! .09 .09 .05 .09 .18 .00 .14 .05 .18 .32 .09 .27 .05 .37 .23 .23 2.42 2.42 !'
- X 1.10 .46 .00 1.46 1.51 .55 .64 .32 .50 .82 .82 .59 .62 1.28 1.28 1/ a 21 13.21 1 $$ .18 .27 .09 .14 1.05 1.01 .69 .46 .37 .18 .46 .64 .78 .69 .59 8.50
.. 8.50 8 NS .18 .18 .00 .05 .00 .05 .50 .18 .23 .23 .31 .41 .27 .27 .32 .55 3.80 3.80 ES .00 .00 .00 .00 .00 .00 .00 .09 .05 .00 .00 .05 .05 .00 .05 .00 .21 .21 l I
29.49 ZCADRAD/194
. CEcoLASALLESTATION hly-September 1993 375ft.VIROSPEEDandVINDDI0ECTION 375-33ft.DIFFERENTIALTENPERATUQE SPEED -- ----- ----- -
VIND DIRECTION CLASSES ----------------- --- STA8IlliY CLASSES ----
CLASS N HE NE ENE E ESE SE SSE S S!V SV VSV V HV W NH TCTAL Eli WU SU N SS NS ES TOTAL EU .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 1NU .00 .00 .00 .00 .00 .00 .00 .09 .05 .00 .00 .00 .00 .37 .00 .00 .50 .50 9SU .00 .00 .00 .05 .00 .00 .00 .09 .14 .14 .05 .00 .14 .21 .14 .00 1.01 t01
-N .32 .00 .00 .50 .46 .09 .09 ,14 .46 .69 .21 .23 .32 .69 .69 .14 5.08 5.08 2$$ .05 .14 .00 .05 .32 .18 .50 .64 1.14 .69 .78 .!T .37 .46 .64 .27 6.49 6.49 4NS .00 .00 .00 .00 .00 .05 .14 .18 .27 .59 .91 .55 .37 .46 .32 .18 4.02 4.02 ES .00 .00 .00 .00 .00 .00 .00 .00 .18 .05 .05 .05 .00 .00 .05 .00 .31 .37 17.47 EU .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 G NU .00 .00 .00 .00 .00 .00 .00 .00 .00 .05 .00 .00 .00 .05 .00 .00 .09 .09 i SU .00 .00 .00 .00 .00 .00 .00 .00 .14 .41 .14 .09 .00 .00 .00 .00 .i8 .il I .00 .00 .00 .00 .00 .00 .00 .18 .81 .59 .32 .05 .2i .55 .27 .00 3.11 3.11 2 SS .00 .00 .00 .00 .00 .00 .09 .23 1.37 1.37 .73 .18 .23 .23 .41 .14 4.98 4.98 4NS .00 .00 .00 .00 .00 .05 .00 .05 .05 .09 .18 .00 .2T .14 .09 .00 .91 .91 ES .00 .00 .00 .00 .00 .00 .00 .00 .00 .05 .05 .00 .00 .00 .14 .00 .23 .23 10.11 T01 4.89 4.02 2.79 4.48 6.13 5.03 f.32 5.21 8.8710.38 8.32 5.21 6.08 8.60 7.54 5.12100.00 .91 4.39 8.37 41.06 29.31 14.13 1.83 100.
VindDirectionbyStability N HE NE ENE E ESE SE SSE S SSV SV VSV V HV XV HV TOTAL -STA81LITYCLASSES-
.00 .00 .05 .00 .05 .00 .00 .23 .14 .it .05 .00 .00 .00 .00 .00 .91 Extressly Unstable
.05 .31 .23 .00 .05 .00 .18 .41 .96 1.01 .50 .05 .00 .41 .00 .18 4.39 ModeratelyUnstable
.50 .t8 .18 .18 .21 .09 .46 .37 .73 1.10 .78 .64 .37 1.01 .91 .59 8.37 SlightlyUnstable 3.52 2.24 1.05 3.34 3.43 2.38 3.16 1.33 2.51 2.61 2.24 1.55 2.29 3.89 3.52 2.01 41.06 Neutral
.59 1.05 1.19 .69 2.15 2.10 2.10 1.74 1.16 3.48 2.42 1.55 2.06 2.06 1.92 1.05 29.31 Sli9htlyStable i
.23 .18
.09 .27 .18 .46 1.33 1.01 1.05 1.51 2.06 1.23 1.33 1.14 .91 1.14 14.13 NederatelyStable
.00 .j0 .00 .00 .00 .00 .09 .14 .32 .27 .27 .18 .05 .09 .27 .14 1.83 Extremelystable i Wind Direction by Vind Speed i HE NE ENE E ESE SE $$E S SSV SV VSV V HV NV NH TOTAL 4INDSPEEDCLASSES-l
.00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 CAtX
.23 .05 .18 .18 .14 .09 .37 .23 .09 .14 .14 .09 .23 .18 .09 .14 2.56 0.8 - 3.5 c;h 1.10 .96 1.55 1.05 1.19 1.19 1.65 1.01 .82 .64 .73 .46 .69 .82 .78 .55 15.18 3.6 - 1.5 s;h 1.60 1.83 .91 .91 1.28 1.78 2.47 1.19 1.69 2.24 2.06 1.23 1.23 1.78 1.46 1.51 25.19 7.6-12.5n;h 1.60 1.05 .14 1.74 2.74 1.60 2.01 1.19 1.60 2.65 1.92 2.01 1.97 2.61 2.47 2.19 29.49 12.6-18.5sph
.37 .14 .00 .59 .78 .32 .73 1.14 2.24 2.15 2.06 1.10 1.19 2.24 1.83 .59 17.47 18.6-24.5t;h
.00 .00 .00 .00 .00 .05 .09 .46 2.42 2.56 1.42 .32 .78 .96 .91 .14 10.11 >24.5s;h ZCADRAD/194 21 of 25
i CEcoLASAllESTATIOX October-December 1993 375ft.WINDSPEEDandWINDOIRECTION 375-33ft.DIffE0EXIIALTENPERATUOE UMBEROFOBSERVATIONS: 2183 YALUES ARE PERCERT OCCURREEE SMEO - - VItD DIRECTION CLASSES -
STABILITYCLASSES CLASS A RNE RE EXE E ESE SE SSE $ $$W SV WS1 V WNW RW XNW TOTAL EU NU SU N SS NS ES TOTAL i i
EU .00 .00 .00 .00 .C0 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 Nu .00 .00 .00 .00 :0 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 C SU .00 .00 .00 . 0". .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 AX .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 l SS .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 NNS .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 ES .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00
.00 l EU .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 l
NU .00 .00 ,00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 1 SU .00 .00 .00 .00 .00 .00 .00 .00 .05 .00 .00 .00 .00 .00 .00 .00 .05 .05
-X .00 .05 .09 .09 .09 .05 .05 .05 .05 .00 .00 .09 .05 .14 .00 .05 .82 .82 3 SS .00 .00 .09 .00 .05 .00 .00 .00 .05 .00 .00 .00 .09 .00 .05 .00 .12 .32 NS .05 .00 .00 .00 .00 .00 .00 .00 .09 .00 .00 .00 .00 .00 .05 .05 .23 .23 ES .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 1.42 EU .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 NU .00 .00 .00 .00 .00 .00 .00 .00 .00 .05 .05 .00 .00 .00 .00 .00 .09 .09 4 $U .00 .09 .05 .00 .00 .00 .00 .00 .00 .00 .05 .05 .00 .00 .00 .00 .23 .23
-X .18 .09 .32 .46 .82 46 .46 .23 .14 .27 .21 .23 .14 .41 .18 .23 4.90 4.90 l
7 $$ .05 .00 .09 .09 .21 .09 .27 .00 .05 .05 .14 .09 .09 .05 .00 .00 1.33 1.33 13 .00 .00 .05 .00 .05 .05 .00 .05 .05 .14 .09 .05 .09 .05 .00 .00 .64 .64 1
ES .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .05 .05 .09 .05 .00 .00 .23 .23 1.42 l
l EU .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 NU .00 .05 .00 .00 .00 .00 ,00 .00 .00 .00 .18 .09 .00 .00 .00 .00 .32 .32 8 $U .00 .05 .05 .00 .00 .00 .00 .00 .05 .00 .18 .18 .00 .00 .00 .00 .50 .50
-N .69 1.01 .96 .50 .64 .21 .41 .05 .64 .54 .37 .60 .87 .27 1.01 1.10 10.03 10.03 1 SS .09 .09 .41 .27 .32 .50 .t8 .09 .09 .18 .14 .18 .18 .00 .18 .05 2.98 2.98 2NS .00 .00 .09 .05 .00 .23 .14 .00 .14 .32 .00 .05 .14 .00 .18 .00 1.33 1.33 ES .00 .00 .00 .00 .00 .00 .00 .00 .05 .05 .14 .00 .05 .00 .05 .05 .31 .37 15.53 l,
l l
EU .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 '
1 NU .00 .00 .00 .00 .00 .00 .00 .00 .00 .18 .05 .00 .00 .00 .00 .00 .23 .23 3 SU .09 .05 .00 .00 .00 .00 .00 .00 .09 .32 .27 .18 .00 .09 .09 .00 1.19 1.19 l
- N 1.33 .96 1.65 .69 .18 .50 1.01 .55 .60 .78 .64 1.01 1,56 1.97 1.51 1.79 16.72 16.72 l 1SS .32 .50 .23 .18 .55 .09 .09 .23 .60 .37 .46 .21 .41 .32 .32 .09 5.04 5.04 l 8NS .23 .05 .00 .00 .05 .05 .14 .09 .27 .46 .09 .09 .09 .09 .32 .05 2.06 2.06 !
ES .00 .00 .00 .00 .00 .05 .09 .14 .23 .14 .00 .09 .00 .18 .00 .00 .92 .92 I 26.16
{
22 of 25 ZCADRAD/194 l I
, l
![
l CECoLASALLESTATION October-December 1993 375ft.VINDSPEE0andVINDDI0ECTION 375-33ft.DIffE0ERTIALTEMPE0ATURE i
l ---------
SPEED --------VIRODIRECTIONCLASSES----------- -- -
- STABILITY CLASSES -------
CLASS X HE XE EXE E ESE SE SSE SV VSV nV S SSV V XV HV TOTAL EU M SU X SS NS ES TOTAL ;
I Eu .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 l 1H .00 .00 .00 .00 .00 .00 .00 .00 .00 .09 .09 .18 .00 .09 .00 .00 .46 46 l 9 Su .0i .00 .00 .00 .00 .00 .00 .00 .09 .Di .18 .09 .00 .32 .00 .il t.05 1.05
-X .92 .32 .09 .32 .23 .09 .05 .37 1.01 1.24 1.19 .13 .55 1.65 1.01 .55 10.31 10.31 2SS .05 .05 .00 .05 .18 .23 .05 .50 .92 .92 1.24 .46 .87 1.37 .23 .00 1.10 1.10 4MS .00 .00 .00 .09 .00 .00 .09 .37 .46 .32 .50 .18 .32 .05 .09 .05 2.52 2.52 ES .00 .00 .00 .00 .00 .00 .00 .09 .27 .14 .32 .23 .18 .32 .05 .00 1.60 1.60 23.04 EU .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 6H .00 .00 .00 .00 .00 .00 .00 .00 .00 .09 .00 .00 .00 .00 .00 .00 .09 .09 iSU .00 .00 .00 .00 .00 .00 .00 .00 .05 .18 .09 .09 .00 .18 .00 .00 .60 .60 X .14 .21 .00 .23 .41 .32 .00 .05 .50 1.33 .69 .32 .96 1.88 1.15 .18 8.43 8.43 l 2SS .00 .00 .00 .00 .37 .09 .09 .69 1.97 2.70 1.97 .64 .64 1.15 .21 .00 10.58 10.58 4 MS .00 .00 .00 .00 .00 .00 .09 .05 .69 1.01 1.37 .37 .05 .05 .00 .00 3.66 3.66 I
ES .00 .00 .00 .00 .00 .00 .00 .14 .18 .50 1.37 .64 .14 .09 .00 .00 3.07 3.01 26.43 T01 4.21 3.62 4.17 3.02 4.21 3.07 3.21 3.71 9.34 12.55 12.19 7.24 1.56 10.71 6.73 4.40 100.00 .00 1.19 3.62 51.21 27.35 VladDirectionbyStability X HE RE EXE E ESE SE $$E $ SSV SV VSV V VH H HV TOTAL -$TABILITYCLASSES-
.00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 Extresely hstable
.00 .05 .00 .00 .00 .00 .00 .00 .00 .41 .37 .27 .00 .09 .00 .00 1.19 Nederately h stable
.!8 .18 .09 .00 .00 .00 .00 .00 .32 .60 .78 .60 .00 .60 .09 .18 3.62 SillhtlyUnstable 3.25 2.70 3.11 2.29 2.38 1.69 1.97 1.28 2.93 4.26 3.16 2.98 4.12 6.32 4.86 3.89 51.21 Xeutral
.50 .64 .82 .60 1.14 1.01 .69 1.51 3.66 4.21 3.94 1.65 2.29 2.89 1.05 .14 27.35 $119htlyStable
.27 .05 .14 .14 .09 .32 46 .55 1,69 2.24 2,06 .73 .69 .23 .64 .14 10.44 ModeratelyStable
.00 .00 .00 .00 .00 .05 .09 .37 .73 .82 1.88 1.01 .46 .64 .09 .05 6.18 ExtreetlyStable viadDirectionbyWindSpeed N ME XE ERE E ESE SE SSE S SSW SV VSV V HV H Hy TOTAL -VIRDSPEEDCLASSES-
.00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 CALN
.05 .05 .18 .09 .14 .05 .05 .05 .23 .00 .00 .09 .14 .14 .09 .09 1.42 0.8 - 3.5 mph
.23 .tl .50 .55 1.15 .60 .f3 .27 .23 .50 .64 46 .41 .55 .18 .23 1.42 3.6 - 7.5 rph
.78 1.19 1.51 .82 .96 1.01 .73 .14 .96 1.19 1.01 1.10 1.24 .27 1.42 1.19 15.53 7.6 12.5 sph 1.97 1.56 1.88 .87 .18 .69 i 33 1.01 1.79 2.24 1.51 1.65 2.06 2.66 2.24 1.92 26.16 12.6-18.5sph 1.05 .37 .09 46 .41 .P .11 1.33 2.75 2.79 3.53 1.88 1.92 3.80 1.37 .18 23. 6 18.6-24.5r;h
.14 .27 .00 .23 .18 .41 .18 .92 3.39 5.82 5.50 2.06 1.19 3.34 1,42 .18 26.43 )24.5eph 23 of 25 ZCADRAD/194
. -- .~ . -- - .
e t
STATION VENT STACK PARTICULATE SAMPLE LOST DURING SHIPMENT I
Description and cause of Event: I The July 1993 station vent stack particulate samples were shipped from i LaSalle Station in a five gallon bucket via Yellow Freight Lines to -)
'TMA/NORCAL in California for analysis in the vendor's laboratory. The i bucket never made it to the vendor. '
The Yellow Freight representative at Marseilles ran a tracer on the shipment for us. Yellow Freight was able to trace the bucket from LaSalle Station to Marseilles, and from Marseilles to the Chicago dock. The Chicago dock paperwork shows it loaded on the truck bound for Tracy California. However, Tracy California shows it as a shortage, that is, their paperwork shows it wasn't on the truck when it got there. Yellow Freight's Marseilles Representative said since it was shipped so long ago (August 24, 1993) they didn't think it was very likely they would be able to locate it, if it was going to turn up it would have by now. They considered the bucket lost.
Although these samples are sent out for analysis every month they are usually not a rad shipment and are able to be shipped together. This month the SVS particulate could not be unconditionally released and had to be shipped as radioactive material. These samples had not been shipped in this manner for the past 18 months.
Although there is a surveillance item on the 25th of each month to verify that the vendor has received the sample the station did not realize this sample had been lost until November 1, 1993. Usually this sample (SVS particulate) is shipped with the Lake Blowdown sample and their is one surveillance for the combined sample shipment. This time the SVS particulate could not be released as unconditional and was sent as a second shipment (radioactive material shipment). On September 24, 1993 TMA/NORCAL acknowledged receipt of the shipment thinking it was the July sample not realizing they had just received the August sample. On November 1,1993 the station Chemistry Department received the July sample analysis from TMA/NORCAL and recognized the results were missing for the SVS particulate sample. The length of time between the shipment date and the date the tracer was placed on the shipment added to the difficulty in tracing the bucket.
The significance of the lost bucket / sample is the failure of LaSalle Station to meet section 12.4.1.B.2 and Table 12.4.1-1 item D of the Station's ODCM. The consequence of the lost bucket / sample is the ODCM requires the station to include this information in the next semi-annual effluent report. The report is required to be completed 60 days af ter the end of the reporting period, in this case December 31, 1993 is the end of the reporting period.
24 of 25 ZCADRAD/194 i
l
i
~
l e 4
' j l
l Corrective Actions:
- 1. Station Chemistry to submit a separate surveillance (G-SURV) for each sample. Each sample will be tracked separately in the future.
- 2. Rad Protection will include the fact that the required ODCM monthly SVS particulate sample was ndssed and include details of this event in the next Semi-Annual Effluent Report.
1 l
l i
25 of 25 ZCADRAD/194