ML20196C268
| ML20196C268 | |
| Person / Time | |
|---|---|
| Site: | LaSalle |
| Issue date: | 12/31/1986 |
| From: | Diederich G COMMONWEALTH EDISON CO. |
| To: | Davis A NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| References | |
| NUDOCS 8802160040 | |
| Download: ML20196C268 (20) | |
Text
.-
LASALLE COUNTY NUCLEAR POWER STATION UNITS ONE-AND TWO DOCKET NUMBERS 50-373 AND 50-374 ERRATA TO THE EFFLUENT AND WASTE DISP _ 4. ANNUAL REPORT (1986)
GASEOUS EFFLUENTS-SUMMATION OF ALL RELEASES First Second Guarter Quarter A. Fission and Activation Gases
- 1. Total release C1 1.63E+03 1.31E+03
- 2. Average release rate for period uCi/sec 2.10E+22 3.70E+02
- 3. Percent of Tech. Spec. limit 6.90E-01 3.90E-01 B.
- 1. Total iodine-131 Ci 5.82E-02 3.04E-03.
- 2. Average release rate for period uCi/sec 2.10E-02 9.40E-04
- 3. Percent of Tech. Spec. limit 1.90E-02 8.90E-04 C. Particulates
- 1. Particulates with T1/2 )8 days Ci 1.36E-03 1.90E-03
- 2. Average release rate for period uCi/sec 1.75E-04 2.42E-04
- 3. Percent of Tech. Spec. limit 6.60E-03 1.70E-02
- 4. Gross alpha radioactivity Ci 2.00E-12 5.00E-12 D. Tritium i
- 1. Total release Ci
.1.52E+00 1.81E+00
- 2. Average release rate for period uCi/see 1.90E-01 2.30E-01
- 3. Percent of Tech. Spec. limit 2.00E-03 2.40E-03 8802160040 861231 PDR ADOCK 05000373 4( \\\\\\
R PDR
./
LASALLE COUNTY NUCLEAR POWER STATION UNITS ONE AND TWO DOCKET NUMBERS 50-373 AND 50-374 ERRATA TO THE EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT (1986)
GASEOUS EFFLUENTS-SUMMATION OF ALL RELERSES Third Fourth Quarter Quarter A. Fission and Activation Bases
- 1. Total release Ci 3.60E+00 4.12E+01
- 2. Average release rate for period uCi/sec 4.50E-01 5.20E+00
- 3. Percent of Tech. Spec. limit 7.00E-05 2.80E-03 B.
- 1. Total iodine-131 Ci 8.00E-04 3.31E-03
- 2. Average release rate for period uCi/see 1.40E-03 9.10E 3. Percent of Tech. Spec. limit 5.30E-04 4.40E-02 C. Particulates
- 1. Partictlates with T1/2 )8 days Ci 8.05E-04 1.48E-03
- 2. Average release rate for period uCi/sec 1.01E-04 1.86E-04
- 3. Percent of Tech. Spec. limit 7.00E-03 5.10E-03
- 1. Total release Ci 6.21E-01 6.71E+00
- 2. Average release rate for period uCi/cee 7.80E-02 8.50E-01
- 3. Percent of Tech. Spec. limit 6.30E-0' 9.00E-03
( " indicates activity of sample is less than LLD given in aci/ml l
l
ERRATA TO THE EFFLUENT AND WASTE DISPOSAL REPORT (1986)
GASEOUS EFFLUENTS-ELEVATED RELEASE Nuclides Released Jan.
Feb.
March First Usarter
- 1. Fission Gases Ar-41 Ci 4.10E+00 4.20E-01 9.80E-03 4.53E+('
Kr-85m Ci 8.10E+01 8.90E+01 1.10E+02 2.80E+0E Kr-87 Ci 5.90E+00 1.20E+01 0.00E+00 1.79E+01 Kr-88 C1 1.20E+02 9.40E+01 1.90E+02 4.04E+02 Xe-131m Ci 0.00E+00 1.10E-01
-6.00E-01 7.10E-01 Xe-133 Ci 8.10E'01 2.40E+02 4.80E+02 8.01E+02 Xe-133m C1 (1.00E-06 5.30E-02 (1.00E-06 5.30E-02 Xe-135 C1 1.20E-02 3.90E+01 5.10E+01 9.00E+01 Xe-135m Ci 0.00E+00 0.00E+00 3.20E+01 3.20E+01 Xe-138 Ci (1.00E-06 (1.00E-06 (1.00E-06 (1.00E-06 Total for period Ci 2.92E+02 4.74E+02 8.64E+02 1.63E+03
- 2. Iodines I-131 Ci (1.00E-11 5.40E-02 4.20E-03 5.82E-02 I-132 Ci (1.00E-11 (1.00E-11 5.50E-04 5.50E-04 I-133 C1 1.00E-01 2.10E-04 1.70E-03 1.02E-01 I-134 Ci 3.80E-03 (1.00E-11 (1. 00E-11 3.80E-03 I-135 Ci 5.90E-04 4.70E-04 (1.00E-11 1.06E-03 Total for period C1 1.04E-01 5.47E-02 6.45E-03 1.66E-01
- 3. Particulates Mn-54 Ci 1.40E-04 4.80E-04 1.40E-04 7.60E-04 Co-58 Ci (1.00E-04 (1.00E-04 (1.00E-04 (1.00E-04 Fe-59 Ci (1.00E-04 (1.00E-04 (1.00E-04 (1.00E-04 Co-69 Ci 1.40E-04 2.70E-04 1.50E-04 5.60E-04 Zn-65 Ci (1.00E-04 (1.00E-04 (1.00E-04 (1.00E-04 Se-75 Ci 3.80E-05 0.00E+00 0.00E+00 3.80E-05 l
Sr-89 Ci 1.10E-11 (1.00E-11 (1.00E-11 1.10E-11 Sr-90 Ci (1.00E-11 6.00E-09 (1. 00E-11 6.00E-09 Cs-134 Ci (1.00E-04 (1.00E-04 (1. 00E-04 (1.00E-04 Cs-137 Ci (1.00E-04 (1.00E-04 (1. 00E-04 (1.00E-04 Ce-141 Ci (1.00E-04 (1.00E-04 (1.00E-04 (1.00E-04 Ce-144 Ci (1.00E-04 (1.00E-04 (1.00E-04 (1.00E-04 Total for period Ci 3.18E-04 7.50E-04 2.90E-04 1.36E-03
(
indicates activity of sample is less than LLD given in uci/ml j
i l
l i
ERRATA TO THE EFFLUENT AND WASTE DISPOSAL REPORT (1986)
GASEOUS EFFLUENTS-ELEVATED RELEASE Nuclides Released April May June Second Guarter
- 1. Fission Gases Ar-41 Ci 6.60E-04 5.30E-06 0.00E+00 6.65E-04 Kr-85m Ci 8.50E+01 1.90E+01 0.00E+00 1.04E+02 Kr-87 Ci (1. 00E-06 9.70E-03 (1.00E-06 9.70E-03 Kr-88 Ci 1.30E+02 4.70E+01 (1.00E-06 1.77E+02 Xe-133 Ci 2.90E+02 1.00E+02 4.70E-01 3.90E+02 Xe-133m Ci (1.00E-06 1.40E-02 (1.00E-06 1.40E-02 Xe-135 Ci 5.70E+02 5.90E+01 3.40E-02 6.29E+02 Xe-135m Ci (1. 00E-06 7.50E+00 (1.00E-06 7.50E+00 Xe-138 Ci (1. 00E-06 (1.00E-06 (1.00E-06 (1.00E-06 l
Total for period Ci 1.08E+03 2.33E+02 5.04E-01 1.31E+03 2.
Iodines I-131 Ci 5.80E-04 2.30E-03 1.60E-04 3.04E-03 1-132 Ci (1.00E-11 4.20E-04 (1.00E-11 4.20E-04 I-133 Ci 1.70E-03 1.20E-03 1.30E-04 3.03E-03 1-134 C1 (1.00E-11 3.90E-04 (1.00E-11 3.90E-04 I-135 Ci (1.00E-11 4.40E-04 (1.00E-11 4.40E-04 Total for period Ci 2.28E-03 4.75E-03 2.90E-04 7.32E-03
- 3. Particulates Mn-54 Ci 7.00E-05 7.90E-05 2.60E-04 4.09E-04 Co-58 Ci (1.00E-04 (1.00E-04 (1.00E-04 (1.00E-04 Fe-59 Ci (1. 00E-04 (1.00E-04 (1.00E-04 (1. 00E-04 Co-60 Ci 1.70E-04 6.00E-04 7.10E-04 1.48E-03 Zn-65 Ci (1.00E-04 (1.00E-04 (1.00E-04 (1. 00E-04 Sr-89 Ci 3.10E-11 (1.00E-11 (1.00E-11 3.10E-11 Sr-90 Ci 9.00E-12 (1. 00E-11 (1.00E-11 9.00E-12 Ag-110m Ci 0.00E+00 0.00E+00 9.30E-06 9.30E-06 Cs-134 Ci (1.00E-04 (1.00E-04 (1.00E-04 (1.00E-04 Cs-137 Ci (1.00E-04 (1.00E-04 (1.00E-04 (1.00E-04 i
Ce-141 Ci (1. 00E-04 (1.00E-04 (1.00E-04 (1. 00L-04K l
Ce-144 Ci (1.00E-04 (1.00E-04 (1.00E-04 (1.00E-04 Total for period Ci 2.40E-04 6.79E-04 9.80E-04 1.90E-03
(
indicates activity of sample is less than LLD given in uci/ml l
ERRATA TO THE EFFLUENT AND WASTE DISPOSAL REPORT (1986)
GASEQUS EFFLUENTS-ELEVATED RELEASE Nuclides Released July Aug.
Sept.
Third Guarter
- 1. Fission Gases Kr-87 Ci (1. 00E-06 (1.00E-06 (1.00E-06 (1. 00E-06 Kr-88 Ci (1.00E-06 (1.00E-06 (1.00E-06 (1. 00E-06 Xe-133 Ci (1.00E-06 (1.00E-06 3.60E+00 3.60E+00 Xe-133m Ci (1.00E-06 (1.00E-06 (1.00E-06 (1.00E-06 Xe-135 Ci (1.00E-06 (1.00E-06 (1.00E-06 (1.00E-06 Xe-138 C1 (1.00E-06 (1.00E-06 (1.00E-06 (1.00E-06 Total for period C1 (1. 00E-06 (1.00E-06 3.60E+00 3.60E+00 2.
Iodines I-131 Ci (1.00E-11 1.40E-04 6.60E-04 8.00E-04 I-132 Ci (1.00E-11 (1.00E-11 2.10E-03 2.10E-03 I-133 Ci (1.00E-11 2.30E-03 3.80E-03 6.10E-03 I-134 Ci (1.00E-11 5.80E-04 (1.00E-11 5.80E-04 I-135 Ci (1.00E-11 (1.00E-11 1.40E-03 1.40E-03 Total for period Ci (1.00E-11 3.02E-03 7.96E-03 1.10E-02
- 3. Particulates Mn-54 Ci 4.70E-05 1.10E-04 1.10E-05 1.68E-04 Co-58 Ci (1.00E-04 (1.00E-04 (1.00E-04 (1.00E-04 Fe-59 Ci (1. 00E-04 (1.00E-04 (1.00E-04 (1.00E-04 Co-60 Ci 8.60E-05 3.70E-04 1.70E-04 6.26E-04 2n-65 Ci (1.00E-04 (1.00E-04 1.10E-05 1.10E-05 Sr-89 Ci (1.00E-11 (1.00E-11 1.30E-11 1.30E-11 Sr-90 Ci (1. 00E-11 (1.00E-11 4.00E-12 4.00E-12
)
Cs-134 Ci (1.00E-04 (1.00E-04 (1.00E-04 (1.00E-04 Cs-137 Ci (1. 00E-04 (1.00E-0)
(1.00E-04 (1. 00E-04 l
Ce-141 C1 (1.00E-04 (1.00E-04 (1.00E-04 (1.00E-04 j
Ce-144 Ci (1.00E-04 (1.00E-04 (1.00E-04 (1.00E-04 i
Total for period C1 1.33E-04 4.80E-04 1.92E-04 8.05E-04
(
indicates activity of sample is less than LLD given in uci/ml i
w ERRATA TO THE EFFLUENT AND WASTE DISPOSAL REPORT (1986)
GASEOUS EFFLUENTS-ELEVATED RELEASE Nuclides Released Oct.
Nov.
Dec.
Fourth Quarter
- 1. Fission Gase-a Ar-41 Ci 0.00E+00 1.50E+00 8.80E-01 2.38E+00 Kr-85m Ci 0.00E+00 8.00E-03 1.80E+00 1.81E+00 Kr-87 Ci (1. 00E-06 (1.00E-06 (1.00E-06 (1.00E-06 Kr-88 Ci (1.00E-06 (1.00E-06 (1.00E-06 (1.00E-06
~.00E+01 3.70E+01 Xe-133 C1 (1. 00E-06 2.70E+01 1
Xe-133m Ci (1.00E-06 (1.00E-06 (1.00E-06 (1.00E-06 Xe-135 Ci (1.00E-06 (1. 00E-06 (1.00E-06 (1.00E-06 Xe-138 C1 (1.00E-06 (1. 00E-06 (1.00E-06 (1.00E-06 Total for period Ci (1.00E-06^
2.85E+01 1.27E+01 4.12E+01
- 2. Iodines I-131 C1 1.50E-03 7.10E-04 1.10E-03 3.31E-03 I-132 Ci 8.50E-03 4.50E-03 1.40E-03 1.44E-02 I-133 C1 1.00E-02 5.80E-03 6.50E-03 2.23E-02 I-134 C1 (1.00E-11 1.50E-03 (1. 00E-11 1.50E-03 I-135 Ci 1.50E-02 6.00E-03 8.90E-03 2.99E-02 Total for period Ci 3.50E-02 1.85E-02 1.79E-02 7.14E-02
- 3. Particulates Cr-51 Ci 0.00E+00 7.50E-04 0.00E+00 7.50E-04 Mn-54 Ci 6.40E-05 1.90E-04 4.10E-05 2.95E-04 Co-58 Ci (1.00E-04 (1.00E-04 (1.00E-04 (1.00E-04 Fe-59 C1 (1.00E-04 (1. 00E-04 (1.00E-04 -(1.00E-04 Co-60 C1 2.80E-04 1.30E-04 2.80E-05 4.38E-04 Zn-65 Ci (1.00E-04 (1.00E-04 (1.00E-04 (1.00E-04 Sr-89 C1 1.60E-09 (1. 00E-11 (1. 00E-11 1.60E-09 Sr-90 Ci (1.00E-11 (1. 00E-11 (1.00E-11 (1.00E-11 Cs-134 C1 (1. 00E-04 (1. 00E-04 (1.00E-04 (1.00E-04 Cs-137 Ci (1.00E-04 (1.00E-04 (1. 00E-04 (1.00E-04 Ce-141 Ci (1.00E-04 (1. 00E-04 (1. 00E-04 (1.00E-04 Ce-144 Ci (1. 00E-04 (1. 00E-04 (1. 00E-04 (1.00E-04 Total for period Ci 3.44E-04 1.07E-03 6.90E-05 1.48E-03
(
indicates activity of semple is less than LLD given in uci/ml
r ERRATA TO THE EFFLUENT AND WASTE DISPOSAL APNUAL REPORT (1986)
LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES First Second Guarter Quarter A. Fission and Activation Products
- 1. Total release (not icluding Ci No No tritium, gases, alpha)
Releases Releases
- 2. Average concentration released uCi/ml
- 3. Maximum concentration released uCi/ml
- 4. Percent of Tech. Spec. limit B. Tritium
- 1. Total release C1
- 2. Average concentration released uCi/ml
- 3. Percent of Tech. Spec. limit C. Dissolved Noble Bases
- 1. Total release Ci
- 2. Average concentration released uCi/ml
- 3. Percent of Tech. Spec. limit D. Gross Alpha Radioactivity
- 1. Total release Ci
- 2. Average concentration released uCi/ml E. Volume of Waste Released liters F. Volume of Dilution Water liters
ERRATA TO THE EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT (1986)
LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES Third Fourth Guarter Guarter A. Fission and Activation Products
- 1. Total release (not icluding Ci 1.78E-02 No tritium, gases, alpha)
Releases
- 2. Average concentration released uCi/ml 1.11E-07
- 3. Maximum concentration released uCi/ml 2.80E-07 4.
Percent of Tech. Spec. limit 1.33E-03 B. Tritium
- 1. Total release C1 1.37E-01
- 2. Average concentration released uCi/ml 3.00E-04
- 3. Percent of Tech. Spec. limit 2.88E-05 C. Dissolved Noble Gases
- 1. Total release Ci 0.00E+00
- 2. Average concentration released uCi/ml N/A
- 3. Percent of Tech. Spec. limit 0.00E+00 D. Gross Alpha Radioactivity
- 1. Total release Ci 3.10E-07
- 2. Average concentration released uCi/ml 2.34E-10 E. Volume of Waste Released liters 4.43E+05 l
F. Volume of Dilution Water liters 1.86E+09 1
ERRATA TO THE EFFLUENT AND WASTE DISPOSAL REPORT (1986)
LIQUID EFFLUENTS Nuclides Released July Aug.
Sept.
-Third Guarter Cr-51 Ci 0.00E+00 0.00E+00 1.40E-03 1.40E-03 Mn-54 Ci 6.00E-05 2.30E-04 4.40E-03 4.69E-03 Fe-55 Ci 6.10E-04 5.90E-04 1.90E-03 3.10E-03 Co-58 Ci 4.90E-06 1.10E-05 3.90E-04 4.06E-04 Fe-59 C1 (5.00E-07 (5.00E-07 2.10E-04 2.10E-04 Co-60 Ci 1.20E-04 2.50E-04 6.50E-03 6.87E-03 Zn-65 Ci (5.00E-07 (5.00E-07 1.40E-04 1.40E-04 As-76 Ci 0.00E+00 0.00E+00 3.00E-05 3.00E-05 Sr-89 Ci 1.00E-06 1.00E-06 5.00E-06 7.00E-06 Sr-90 Ci 2.90E-08 2.10E-08 1.00E-07 1.50E-07 Mo-99 Ci (5. 00E-07 (5.00E-07 (5.00E-07 (5.00E-07 Sb-124 Ci 0.00E+00 0.00E+00 1.40E-05 1.40E-05 I-131 Ci (1.00E-06 (1.00E-06 (1.00E-06 (1.00E-06 Cs-134 C1 (5.00E-07 (5.00E-07 (5.00E-07 (5.00E-07 Cs-137 Ci (5.00E-07 (5.00E-07 (5.00E-07 (5.00E-07 Ce-141 Ci (5.00E-07 (5.00E-07 (5.00E-07 (5.00E-07 Ce-144 Ci (5.00E-07 (5.00E-07 (5.00E-07 (5.00E-07 Xe-133 Ci (1.00E-05 (1.00E-05 (1.00E-05 (1. 00E-05 Xe-133m Ci (1.00E-05 (1. 00E-05 (1.00E-05 (1.00E-05 Xe-135 Ci (1. 00E-05 (1.00E-05 (1.00E-05 (1.00E-05 Total for period Ci 7.96E-04 1.08E-03 1.50E-02 1.69E-02
(
indicates activity of sample is less than LLD given in uci/ml
ERRATA TO THE EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT (1986)
SCLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL Jan.
Feb.
Mar.
First Guarter
- 1. Spent resins, filter sludges, evaporator bottoms, etc.
- a. Quantity shipped cu.m.
5.90E+01 4.80E+01 3.00E+01 1.37E+02
- b. Total activity (measured) Ci 3.40E+01 5.50E+01 4.20E+01 1.31E+02
- c. Major nuclides (estimate)
Co-60 19 19 19 Mn-54 32 32 32 Cr-51 22 22 22
- e. Container volume cu. m.
2.10E-01 2.10E-01 2.10E-01 3.30E-01
- f. Solidification agent Ceraent Cement Cement
- 2. Dry compressible waste, contaminated equipment, etc.
- a. Quantity shipped
- u. m.
1.70E+01 3.60E+01 1.70E+01 7.00E+01
- b. Total activity (measured) Ci 2.10E-01 1.50E+00 1.60E-01 1.87E+00
- c. Major nuclides (estimate)
Co-60 16 19 28 Mn-54 28 31 28 Cr-51 28 21 22
- e. Container volume cu. m.
2.10E-01 2.10E-01 2.10E-01 3.30E-01 3.30E-01 l
'l
ERRATA TO THE EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT (1986)
SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL April May June
'Second Quarter
- 1. Spent resins, filter sludges, evaporato" bottoms, etc.
- a. Quantity shipped cu.m.
2.10E+01 2.70E+01 3.10E+0!
7.90E+01
- b. Total activity (measured) Ci 2.40E+02 4.50E+02 3.30E+01 7.23E+02
- c. Major nuclidos (tstimate)
Co-60 19 19 19 Mn-54 32 32 32 Cr-51 1
22 22 22
- e. Container volume cu. e.
2.10E-01 2.10E-01 2.10E-01
- f. Solidification agent Cement Cement Cement
- 2. Dry compressible waste, contaminated equipment, etc.
- a. Quantity shipped cu.m.
1.80E+01 3.60E+01 1.90E+V1 7.30E+01
- b. Total activity (measured) Ci 4.10E-01 1.00E+00 3.20E-01 1.73E+00
- c. Major nuclides (estimate)
Co-60 20 20 20 Mn-54 30 30 30 Cr-51 20 20 20
- e. Container volume cu. m.
2.10E-01 2.10E-01 2.10E-01 2.70E+00 2.90E-01
ERRATA TO THE EFFLUENT AND WY.3TE DISPOSAL ANNUAL itEPORT (1986)
SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL July Aug.
Sept.
Third Quarter
- 1. Spent resins, filter sludges, evaporstor bottoms, ate, a.
Quantity shipped cu.m.
3.60E+01 5.80E+01 8.20E+01
- 1. 76E4 02
- b. Total activity (measured) Ci 3.80E+01-6.20E+01 5.70E+01 1.57E+02
- c. Major nuclides (estimate)
Co-60 f.
22 20 20 Mn-54 32 32 32 Fe-55 19 03 03
- e. Container volume eu, m.
2.10E-01 2.10E-01 2.10E-01
- f. Solidification agent Cement Cement Cement
- 2. Dry compressible waste, contaniinated equipoent, etc.
- 4. Quantity shipped cu.m.
1.60E+01 2.00E+0i 1.40E+01 5.00E+01
- b. Total activity (measured) Ci 1.70E-01 4.30E-01 5.50E-01 3.15E+00
- c. Major nuclides (estimate)
Co-60 28 28 28 Mn-54 28 28 2s Fe-55 16 16 16
- e. Container volume cu. m.
2.10E-01 2.10E-01 2.10E-01 2.90E-01 3.30E-01 2.70E+00 2.70E+00 t
i W-*
vy n
y
,y
-y_,,,
1 l
i ERRATA TO THE EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT (1986)
SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL Oct.
Nov.
Dec.
-Fourth Guarter
- 1. Spent resins, filter sludges, evaporator bottoms, etc.
- a. Quantity shipped cu.m.
6.30E+01 5.80E+01 4.30E+01 1.64E+02
- b. Total activity (measured) Ci 5.00E+01 9.00E+01 3.90E+01 1.79E+02
- c. Major nuclides (estimate)
Co-60 20 36 19 Mn-54 32 25 32 Cr-51 22 00 22 Fe-55 00 20 11
- e. Container volume cu. m.
2.10E-01 2.10E-01 2.10E-01 2.70E+00 4.80E+00
- f. Solidification agent Cement Cement Cement
- 2. Dry compressible waste, contaminated equipment, etc.
- a. Quantity shipped cu.m.
1.40E+01 0.00E+00 3.90E+01 5.30E+01
- b. Total activity (measured) Ci 1.30E-01 0.00E+00 5.50E-01 6.80E-01
- c. Major nuclides (estimate)
Co-60 28 28 Mn-54 28 28 Fe-55 16 16
- d. Container type LSA LSA
- e. Container volume cu. m.
2.10E-01 2.10E-01 3.30E-01 3.30E-01 2.70E+00 2.70E+00 l
ERRATA TO THE EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT (1986)
SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (CONTINUED)
- 3. Solid waste disposition Date Transport Company Destination 01/06/86 HN Richland, WA 01/09/86 HN Richland, WA 01/16/86 TSMT Richland, WO 01/20/86 HN Barnwell, SC 01/22/86 HN Darnwell, SC 01/24/86 HN Richland, WA 01/27/80 HN Barnwell, SC 01/30/86 HN Barnwell, SC 02/03/86 HN Barnwell, SC 02/04/J6 HN Barnwell, SC 02/06/86 HN Barnwc11, SC 02/07/B6 HACKE Barnwell, SC 02/07/86 HN Barnwell, SC 02/10/86 HN Barnwell, SC 02/13/86 HN Barnwell, SC 02/14/86 HN Barnwell, S?
02/14/86 HN Barnwell, SC 02/18/86 HN Barnwell, SC 02/19/86 HN Barnwell, SC 02/20/86 HN Barnwell, SC 02/21/36 HN Barnwall, SC 02/24/86 HN Barnwell, SC 02/25/86 HN Barnwell, SC 02/28/86 HACKE Richland, WA 03/06/86 HACKE Richland, WA 03/10/86 HN Barnwell, SC 03/14/'36 HN Barnwell, SC 03/18/86 HN Richland, WA 03/25/86 HN Richland, WA 04/01/85 TSMT Richland, WA 04/02/06 HN Richland, WA 04/03/86 HN Richland, WA 04/67/86 CN Richland, WA 04/15/E6 CN Richland, WA Transport Company Kev HACKE = Ray Hacke Trucking Company HN = Hittman Nuclear TSMT = Tri-State Motor Transport
. _,. _. ~. _ -.. _ _ _
- 3. Solid waste disposition (continued)
Date Transport Company Destination 04/22/86 CN Richland, WA 04/24/86 CN Richland, WA 04/24/86 HN Pichland, WA 05/01/86 CN Richland, WA 05/01/86 TSMT Ricnland, WA 05/05/86 CN Richland, WA 05/08/86 CN Richland, WA 05/13/86 CN Richland, WA 05/15/86 CN Richland, WA 05/21/86 CN Richland, WA 05/22/86 CN Richland, WA 05/23/86 CN Richland, WA 03/29/86 TSMT Richlano, WA 05/30/86 HN Barnwell, SC 06/02/86 HN Barnwell, SC 06'03/86 HN Barnwell, SC 06/04/86 HN Barnwell, SC 06/05/86 HN Barnwell, SC 06/06/86 HN Barnwell, SC 06/09/86 HN Barnwell, SC 06/17/86 HN Barnwell, SC 06/17/86 TSMT Hanford, WA 06/19/86 HN Hanford, WA 06/23/86 HN Barnwell, SC 06/23/86 HN Barnwell, SC 07/02/86 HN Barnwell, SC 37/02/86 TSMT Richland, WA 07/07/86 HN Barnwell, SC 07/09/86 HN Barnwell, SC 07/18/86 HN Barnwell, SC 07/21/86 HN Barnwell, SC 07/22/86 HN Barnwell, SC 07/24/86 HN Barnwell, SC 07/25/86 HN Barnwell, SC 07/28/86 HN Barnwell, SC 07/29/86 HN Barnwell, SC 07/30/86 HN Barnwell, SC 07/31/86 HN Bcenwell, SC Transport Company Key HACKE = Ray Hacke Trucking Company HN = Hittman Nuclear TSMT = Tri-State Mctor Trar. sport
- 3. Solid waste disposition (continued)
Date Iransport Company Destination 08/01/86 HN Barnwell, SC 08/04/36 HN Barnwell, SC 08/07/86 TSMT Richland, WA 08/07/86 HN Barnwell, SC 08/08/86 HN Barnwell, SC 03/12/86 HN Barnwell, SC 08/13/86 HN Barnwell, SC 08/14/86 HN Barnwell, SC 08/15/86 HN Barnwell, SC 08/18/86 HN Barnwell, SC 08/19/86 HN Barnwell, SC 08/20/86 HN Barnwell, SC 08/21/86 HN Barnwell, SC 08/22/86 HN Barnwell, SC 08/25/86 HN Barnwell, SC 08/26/86 HN Barnwell, SC 08/27/86 HN Barnwell, SC 08/29/86 HN Barnwell, SC 08/29/86 HN Barnwell, SC 09/02/86 HN Barnwell, SC 09/04/86 HN Barnwell, SC 09/04/86 HN Barnwell, SC 09/05/86 HN Barnwell, SC 09/08/86 HN Barnwell, SC 09/12/86 TSMT Richland, WA 09/11/86 HN Barnwell, SC 09/12/86 HN Barnwell, SC 09/11/86 HN Barnwell, SC 09/15/86 HN Barnwell, SC 09/16/86 HN Barnwell, SC 09/17/86 HN Barnwell, SC 09/18/86 HN Barnwell, SC 09/19/86 HN Barnwell, SC 09/22/86 HN Barnwell, SC 09/26/86 TSMT Richland, WA 09/25/86 HN Barnwell, SC 09/26/86 HN Barnwell, SC 09/29/86 HN Barnwell, SC Transport Company Meg HACKE = Ray Hacke Trucking Company HN = Hittrnan Nuclear TSMT = Tri-State Motor Transport
a
- 3. Solid waste disposition (continued)
Date Transport Company Destination 09/30/86 HN Barnwell, SC 10/01/86 HN Barnwell, SC 10/02/86 HN Barnwell, SC 10/03/86 HN Barnwell, SC 10/06/86 HN Barnwell, SC 10/07/86 HN Barnwell, SC 10/09/86 HN Barnwell, SC 10/10/86 HN Barnwell, SC 10/10/86 HN Barnwell, SC 10/14/86 HN Barnwell, SC 10/15/86 HN Barnwell, SC 10/16/86 HN Barnwell, SC 10/17/86 HN Barnwell. SC
{
10/20/86 HN Barnwell, SC 10/23/86 TSMT Richland, WA 10/23/86 HN Barnwell, SC 10/28/86 HN Barnwell, SC 10/29/86 HN Barnwell, SC 10/30/86 HN Barnwell, SC 10/31/86 HN Barnwell, SC 11/05/86 HN Barnwell, SC 11/06/86 HN Barnwell, SC 11/07/86 HN Barnwell, SC 11/10/86 HN Barnwell, SC 11/12/86 HN Barnwell, SC 11/13/86 HN Barnwell, SC 11/13/86 HN Barnwell, SC 11/14/86 HN Barnwell, SC 11/17/86 HN Barnwell, SC 11/19/86 HN Barnwell, SC 11/20/86 HN Barnwell, SC 11/20/86 HN Barnwell, SC 11/21/86 HN Barnwell, SC 11/24/86 HN Barnwell, SC
!.1/25/86 HN Barnwell, SC 11/26/86 HN Barnwell, SC 12/01/86 HN Barnwell, SC I
12/02/86 HN Barnwell, SC
)
Transoort Company key HACKE = Ray Hacke Trucking Company HN = Hittman Nuclear l
TSMT = Tri-State Motor Transport J
- 3. Solid waste disposition (continued)
Date Transport Company Dg,5tination 12/04/85 HN Barnwell, SC 12/04/86 TSMT Hanford, WA 18/08/86 HN Barnwell, SC 12/09/86 HN Barnwell, SC 12/10/86 HN Parnwell, SC 12/11/026 HN Barnwall, SC 12/12/86 HN Barnwell, SC 22/15/86 HN Barnwell, SC 12/16/86 HN Barnwell, 6C 12r19/86 HN Barnwell, SC 12/19/86 TSMT Hanford, WA 12/22/86 HN Barnwell, SC 12/30/86 HN Barnwell, SC Transport Company Kev HRCKE = Ray Hacke Trucking Company HN = Hittman Nuclear TSMT = Tri-State Motor Transport
DM (5
/'
Commonw 2lth Edison l
..m s
[
) LaSalle County Nuclear Station j
f
_. ;r Rural Route #1, Box 220 -
Marseilles, Illinois 61341 l
\\
7
\\
/
Telephone 815/357-6761
' PRIORITY ROUf! Nil l
{Irtt e
I 7@!-
- !?i'-
5
$L
-fw-g,70f Vr A
filh January 21, 1988 Mr. A. Bert Davis Regional Administrator Directorate of Inspection and Enforcement Region III U.
S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137
SUBJECT:
LaSalle County Station Operating Reoort, NRC Dockets 450-373 and
- 50-374 Enclosed is an errata to Parts 1 and 2 of the 198o LaSalle County Station Operating Report, reporting radioactive effluents for January through December.
Two copies of the report are provided for your use. One copy will be forwarded to Document Control and the NRC Resident Inspector will receive a report as outlined in the November 1986 Federal Register.
Sincerely,
[. 0. $-
,'/sG.
J. Diederich Station Manager LaSalle County Station GJD/Lwa/xx/sje Enclosure DOCUMENT ID 0643h/
V'E.3 8 1ggg
.