Text
_.
Commonwealth Miv,n onninny 1.a$alk Gencrating Station 501 North 21st lhiad Marscifics, it 6 u i s ens 7 T'cl 8 5-3574761 February 15,1995 U.S. Nuclear Regulatory Commission Region 111 801 Warrenville Road Lisle, Illinois 60532-4351 Attn: Chief Reactor Support Programs Branch Dear Sir Enclosed is the Semi-annual Radioactive Effluent Report for July through December, 1994 for LaSalle County Nuclear Station, Docket Numbers 50-373 and 50-374.
Two copies of the report are provided for your use. Two copies will be forwarded to the Document Control Desk and one copy to the Senior Resident inspector.
f Sincerely, 1
1, d7 D.. Ray
. Station Manager LaSalle County Station DJR/TG/mkl Attachment cc:
Document Control Desk, U.S. NRC (2)
I"inois Department of Nuclear Safety i
e Tierican Nuclear insurers B 3.1.
U.S. EPA Murray and Trettel, Inc.
j Teledyne isotopes Midwest Laboratory 1
Chemistry Support (Downers Grove)
]
NRC Senior Resident inspector (LaSalle) h Site Quality Verification (LaSalle) g Central File Illini State Park EP File: EPG-01-R09 9502280124 941231 FEB 2 21995 PDR ADOCK 05000373 R
PDR A Unkom company
l f4 LASALLE COUNTY NUCLEAR POWER STATION UNITS ONE AND TWO DOCKET NUMBERS 50-373 AND 50-374 EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1994)
GASEOUS EFFLUENTS-SUMMATION OF ALL RELEASES Estimated Third Fourth Total Quarter Quarter Error %
A.
Fission and Activation Gases 1.
Total release ci 3.68E-03 3.69E-03 36 2.
Average release rate for period uCi/sec 4.68E-04 4.69E-04 B.
Iodines 1.
Total iodine-131 Ci 8.44E-04 2.52E-04 35 2.
Average release rate for period uCi/sec 1.07E-04 3.21E-05 C.
Particulates 1.
Particulates with T1/2 >8 days Ci 2.62E-03 1.99E-05 2.
Average release rate for period uCi/sec 3.33E-04 2.50E-06 29 3.
Gross alpha radioactivity (estimate)Ci
<1.00E-11 <1.00E-11 D.
Tritium 1.
Total release ci 3.31E+01 3.87E+01 19 2.
Average release rate for period uci/sec 4.21E+00 4.92E+00
"<" indicates activity of sample is less than LLD given in uci/ml t-P i
rad / misc /194-93b.wpf 1 of 25
e c.
. EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1994)
GASEOUS EFFLUENTS-ELEVATED RELEASE Unit 1 and Unit 2 Continuou9 Mode Third Nuclides Released July August September Quarter 1.
Fission Gases Ar-41 Ci
<1.00E-06
<1.00E-06
<1.00E-06
<1.00E-06 Kr-85 Ci
<1.00E-06
<1.00E-06
<1.00E-06
<1.00E-06 Kr-85m Ci
<1.00E-06
<1.00E-06
<1.00E-06
<1.00E-06 Kr-87 Ci
<1.00E-06
<1.00E-06
<1.00E-06
<1.00E-06
~
Kr-88 Ci
<1.00E-06
<1.00E-06
<1.00E-06
<1.00E-06 Xe-133 Ci 4.13E-04
<1.00E-06 2.55E-03 2.96E-03 Xe-133m Ci
<1.00E-06
<1.00E-06
<1.00E-06
<1.00E-06' Xe-135 Ci 1.00E-04
<1.00E-06 7.15E-04 7.15E-04 Xe-135m Ci
<1.00E-06
<1.00E-06
<1.00E-06
<1.00E-06 Xe-138 Ci
<1.00E-06
<1.00E-06
<1.00E-06
<1.00E-06 4
i Total for period Ci 4.13E-04
<1.00E-06 3.27E-03 3.68E-03 l
2.
<1.00E-11 3.00E-05
<1.00E-11 3.00E-05 t
I-132 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 I-133 Ci 6.83E-05 3 96E-04 3.50E-04 8.14E-04 I-134 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 I-135 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Total for period Ci 6.83E-05 4.26E-04 3.50E-04 8.44E-04 3.
Particulates Cr-51 Ci
<1.00E-11 3.88E-04
<1.00E-11 3.88E-04 Mn-54 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Co-58 Ci
<1.00E-11 3.69E-05
<1.00E-11 3.69E-05 Fe-59 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Co-60 C1 1.52E-03 4.35E-04
<1.00E-11 1.96E-03 Zn-65 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Sr-89 (Estimate)
Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Sr-90 (Estimate)
Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Nb-95 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Mo-99 Ci
<1.00E-11
<*.00E-11
<1.00E-11
<1.00E-11 Cs-134 Ci
<1.00E-11
<1.00E-11
<1.00E-11'
<1.00E-11 Cs-137 Ci
<1.00E-11
<1 00E-11
<1.00E-11
<1.00E-11 Ba-140 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 La-140 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Ce-141 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11
+
Ce-144 Ci
<1.00E-11 7.82E-05 1.62E-04 2.40E-04 Total for period Ci 1.52E-03 9.38E-04 1.62E-04 2.62E-03
"<" indicates activity of sample is less than LLD given uci/nd 4
r l'
1 rad / misc /194-93b.wpf 2 of 25
?
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1994)
GAT,EOUS EFFLUENTS-ELEVATED RELEASE Unit 1 and Unit 2 Continuous Mode Fourth Nuclides Released October November December Quarter 1.
Fission Gases Ar-41 C1 2.54E-05
<1.00E-06
<1.00E-06 2.54E-05 Kr-85 Ci
<1.00E-06
<1.00E-06
<1.00E-05
<1.00E-06 Kr-85m Ci
~1.00E-06
<1.00E-06
<1.00E-06
<1.00E-06 Kr-87 Ci
<1.00E-06
- 1. 00E-06
<1.00E-06
<1.00E-06 Kr-88 Ci
<1.00E-06 41.00E-06
<1.00E-00
<1.00E-06 Xe-133 C1 1.16E-08
<1.00E-06 3.36E-03 3.36E-03 Xe-133m Ci
<1.00E-06
<1.00E-06
<1.00E-06
<1.00E-06 Xe-135 Ci 8.97E-07
<1.00E-06 3.00E-04 3.01E-04 Xe-135m Ci
<1.00E-06
<1.00E-06
<1.00E-06
<1.00E-06 Xe-138 Ci
<1.00E-06
<1.00E-06
<1.00E-06
<1.00E-06 Total for period Ci 2.63E-05
<1.00E-06 3.66E-03 3.69E-03 2.
Iodines 1-131 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 I-132 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 I-133 Ci
<1.00E-11 2.52E-04
<1.00E-11 2.52E-04 I-134 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 I-135 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Total for period Ci
<1.00E-11 2.52E-04
<1.00E-11 2.52E-04 3.
Particulates Cr-51 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Mn-54 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Co-58 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Fe-59 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Co-60 Ci
<1.00E-11 1.99E-05
<1.00E-11 1.99E-05 Zn-65 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Sr-89 (Estimate)
Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Sr-90 (Estimate)
Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Nb-95 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Mo-99 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Cs-134 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Cs-137 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Ba-140 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 La-140 Ci
<1.00E-11
<1.00E-l'
<1.00E-11
<1.00E-11 Ce-141 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Ce-144 Ci
< 1. 00 E-11
<1.00E-11
<1.00E-11
<1.00E-11 Total for period C1
<1.00E-11 1.99E-05
<1.00E-11 1.99E-05
"<" indicates activity of sample is less than LLD given uci/ml 1
rad / misc /194-93b. wpf 3 of 25
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1994 UNIT ONE LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES ESTIMATED Third Fourth TOTAL Quarter Quarter ERROR %
A.
Fission and Activation Products 1.
Total release (not including Ci 0.00E+00 4.37E-03 9%
tritium, gases, alpha) 2.
Average concentration released uCi/ml N/A 6.99E-05 3.
Maximum concentration released uCi/ml N/A 6.99E-05 B.
Tritium 1.
Total release ci 0.00E+00 1.45E-01 8%
2.
Average concentration released uCi/ml N/A 4.34E-03 C.
Dissolved Noble Gases 1.
Total release ci 0.00E+00 0.00E+00 7%
2.
Average concentration released uCi/ml N/A N/A D.
Gross Alpha Radioactivity 1.
Total release Ci 0.00E+00 2.31E-07 N/A 2.
Average concentration released uCi/ml N/A
<3.69E-09 E.
Volume of Waste Released (prior to dilution) liters 0.00E+00 6.26E+04 F.
Volume of Dilution Water liters 0.00E+00 5.93E+07
"<" indicates activity of sample is less than LLD given in uCi/ml rad / misc /194-93b.wpf 4 of 25 j
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1994)
UNIT ONE BATCH MODE LIQUID EFFLUENTS Third iNuclides Released
. July August September Quarter Cr-51 Ci Mn-54 Ci No No No No Fe-55 Ci Releases Releases Releases Releases Co-58 Ci Fe-59 Ci Co-60 Ci Zn-65 Ci Sr-8 Ci
-Sr-90 Ci Nb-95 Ci
'Zr-95 Ci Mo-99 Ci Tc-99m Ci I-131-Ci Cs-134 Ci Cs-137 Ci Ba-140 Ci La-140 C1 Ce-141 Ci Co-144 Ci Total for period Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00' Xe-131m Ci Xe-133m Ci Xe-133 Ci Xe-135m Ci Xe-135 Ci
"<" indicates activity of sample is less than LLD given in uCi/ml rad / misc /194-93b.wpf 5 of 25
??:
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1994)
UNIT ONE BATCH MODE 4
LIQUID EFFLUENTS Fourth
~
Nuclides Released October November December Quarter Cr-51 Ci
<5.00E-07 No No
<5.00E-07 Mn-54 Ci 1.83E-04 Releases Releases 1.83E-04 Fe-55 Ci 2.03E-03 2.03E-03 Fe-59 Ci
<5.00E-07
<5.00E-07 Co-60 Ci 2.15E-03 2.15E-03 i
Zn-65 Ci
<5.00E-07
<5.00E-07 Sr-89 Ci 8.20E-08 8.20E-08 Sr-90 Ci 4.82E-08 4.82E-08 Zr-95 Ci
<5.00E-07
<5.00E-07 Mo-99 Ci
<5.00E-07
<5.00E-07 I-131 Ci
<1.00E-06
<1.00E-06 Cs-134 Ci
<5.00E-07
<5.00E-07 Cs-137 Ci 1.14E-05 1.14E-05 Ba-140 Ci
<5.00E-07
<5.00E-07 i
La-140 Ci
<5.00E-07
<5.00E-07 Ce-141 Ci
<5.00E-07
<5.00E-07 Ce-144 Ci
<5.00E-07
<5.00E-07 Total for period Ci 4.37E-03 0.00E+00 0.00E+00 4.37E-03 Xe-131m Ci
<1.00E-05
<1.00E-05 Xo-133m Ci
<1.00E-05
<1.00E-05 Xo-133 Ci
<1.00E-05
<1.00E-05 Xe-135m Ci
<1.00E-05
<1.00E-05 Xe-135 Ci
<1.00E-05
<1.00E-05 4
"<" indicates activity of sample is less than LLD given in uCi/ml rad / misc /194-93b.wpf 6 of 25
.~
d EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1994)
UNIT TWO LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES Third Fourth Quarter Quarter
. A.
Fission and Activation Products 1.
Total release (not including Ci 0.00E+00 0.00E+00 tritium, gases, alpha) 2.
Average concentration released uCi/ml N/A N/A 3.
Maximum concentration released uCi/ml N/A N/A B.
Tritium 1.
Total release ci 0.00E+00 0.00E+00 2.
Average concentration released uCi/ml N/A N/A C.
Dissolved Noble Gases 1.
Total release Ci 0.00E+00 0.00E+00 2.
Average concentration released uC1/ml N/A N/A D.
Gross Alpha Radioactivity 1.
Total release Ci 0.00E+00 0.00E+00 2.
Average concentratt.on released uCi/ml N/A N/A E.
Volume of Waste Released liters 0.00E+00 0.00E+00 P.
Volume of Dilution Water liters 0.00E+00 0.00E+00
"<" indicates activity of semple is less than LLD given in uCi/ml I
rad / misc /194-93b.wpf 7 of 25
a EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1994)
UNIT TWO BATCH MODE LIQUID EFFLUENTS Third Nuclides Released July August September Quarter Cr-51 C1 Mn-54 Ci No No No No Fe-55 Ci Releases Releases Releases Releases co-58 Ci Fe-59 Ci Co-60 Ci Zn-65 Ci Sr-89 Ci Sr-90 Ci Nb-95 Ci Zr-95 Ci Mo-99 Ci Tc-99m Ci I-131 C1 Cs-134 Ci Cs-137 Ci Ba-140 Ci La-140 Ci Ce-141 Ci Ce-144 Ci Total for period Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Xe-131m Ci Xe-133m Ci Xe-133 Ci Xe-135m Ci Xe-135 Ci
"<" indicates activity of sample is less than LLD given in uC1/ml rad / misc /194-93b wpf 8 of 25 i
a
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1994)
UNIT TWO BATCH MODE LIQUID EFFLUENTS Fourth Nuclides Released October November December Quarter Cr-51 Ci No No No No Mn-54 Ci Releases Releases Releases Releases Fe-55 C1 Co-58 Ci Fe-59 Ci Co-60 Ci Zn 65-Ci Sr-89 Ci Sr-90 Ci Nb-95 Ci I
Zr-95 Ci Mo Ci Tc-99m C1 I-131 Ci Cs-134 Ci Cs-137 C1 Ba-140 Ci La-140 Ci Ce-141 Ci Ce-144 Ci Total for period Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Xe-131m Ci Xe-133m Ci Xc-133 Ci Xe-135m Ci Xe-135 Ci
"<" indicates activity of sample is less than LLD given in uCi/ml l
l l
rad / mis c/194-93b. wpf 9 of 25
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1994)
MAXIMUM DOSES RESULTING FROM RELEASES Third Fourth Quarter Quarter A.
Gaseous Effluents (Units One and Two)
'1.
Gamma air mrad 3.79E-09 2.53E-09 2.
Beta air mrad 1.29E-09 1.10E-09 3.
Total body mrem 2.85E-09 1.90E-09 4.
Skin mrem 3.40E-09 2.28E-09 5.
Organ (infant thyroid) mrem 0.00E+00 0.00E+00 B.
Liquid Ef fluents (Unit One) 1.
Total body mrem 0.00E+00 5.84E-06 4.
Internal organ (adult liver) mrem 0.00E+00 1.51E-05
-C.
Liquid Effluents (Unit Two) 1.
Total body mrem 0.00E+00 0.00E+00 4.
Internal organ mrem 0.00E+00 0.00E+00 COMPLIANCE STATUS A.
Gaseous Effluents (Units One and Two) 1.
Gamma air
% of Tech. Spec. Limit 0.00 0.00 2.
Beta air
% of Tech. Spec. Limit 0.00 0.00 3.
Total body
% of Tech. Spec. Limit 0.00 0.00 4.
Skin
% of Tech. Spec. Limit 0.00 0.00 5.
Organ
% of Tech. Spec. Limit 0.00 0.00 The maximum dose resulting from releases include nuclides with half-lives less than eight days.
B.
Liquid Effluents (Unit One) 1.
Total body
% of Tech. Spec. Limit 0.00 0.00 2.
Internal organ
% of Tech. Spec. Limit 0.00 0.00 C.
Liquid Effluents (Unit Two) 1.
Total body
% of Tech. Spec. Limit 0.00 0.00 2.
Internal organ (adult liver)
% of Tech. Spec. Limit 0.00 0.00 The maximum dose resulting from releases include nuclides with half-lives less than eight days.
rad / misc /194-93b.wpf 10 of 25
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1994)
SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL Third July August September Quarter
.l.
Spent resins, filter sludges, NO NO NO evaporator bottoms, etc.
SHIPMENTS SHIPMENTS SHIPMENTS N/A a.
Quantity shipped cu.m.
b.
Total activity Ci c.
Major nuclides (estimate %)
.d.
Container type e.
Container volume cu.m.
f.
Solidification agent
.2.
Dry compressible waste, contaminated equipment, etc.
a.
Quantity shipped cu.m.
b.
Total activity Ci c.
Major nuclides (estimate %)
d.
Container type e.
Container volume cu.m.
i i
l rad / misc /194-93b.wpf 11 of 25 1
)
c:
-o -
J
- e-EFFLUENT AND DASTE DISPOSAL SEMI-ANNUAL REPORT (1994)
SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL
+
Third July August September Quarter 3.
Other a.
Quantity shipped cu.m.
NO NO NO N/A SHIPMENTS SHIPMENTS SHIPMENTS b.
Total activity Ci c.
Major nuclides (estimate %)
d.
Container type e.
Container volume cu.m.
.4.
Irradiated Components a.
Number cf shipments b.
Mode of Transportation c.
Destination 5.
Solid Waste Disposition a.
' Number of Shipments b.
Mode of Transportation 5 c.
Destination 5
rad / misc /194-93b.wpf 12 of 25 e
-,,.--o-e y
y
.rg
?
)
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1994) 1 SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL Fourth October November December Quarter 1.
Spent resins, filter sludges, NO NO NO N/A evaporator bottoms, etc.
SHIPMENTS
.SHI PMENTS SHIPMENTS e :,
a.
Quantity shipped cu.m.
b.
Total activity Ci c.
Major nuclides d.
Container type e.
Container volume cu.m.
f.
Solidification agent 2.
Dry compressible waste, contaminated equipment, etc.
a.
Quantity shipped cu.m.
b.
Total activity Ci c.
Major nuclides (estimate %)
d.
Container type e.
Container volume cu.m.
t rad / misc /194-93b.wpf 13 of 25
.~....
?
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1994) 4
. SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL Fourth October November December Quarter 3.
Other a.
Quantity shipped-cu.m. NO NO NO N/A SHIPMENTS SHIPMENTS SHIPMENTS b.
Total activity C1 c.
Major nuclides (estimate %)
d.
container type e.
Container volume cu.m.
4.
Irradiated Components a.
Number of shipments b.
Mode of Transportation c.
Destination 5.
Solid Waste Disposition a.
Number of Shipments b.
Mode of Transportation c.
Destination rad / misc /194-93b.wpf 14 of 25
r
=
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1994) i Supplemental Information
'l.
Regulatory Limits a.
Gaseous Effluents 1)
The air dose due to noble gases released in gaseous effluents, from each reactor unit, from the site shall be limited to the following:
a)
During any calendar quarter:
Less than or equal to 5 mrad for gamma radiation and less than or equal to 10 mrad for beta radiation, and 4
b)
During any calendar year: Less than or equal to 10 mrad for gamma radiation and less than or equal to 20 mrad for beta radiation.
=
2)
The dose to an individual from radioiodines and radioactive materials in particulate form, and radionuclides, other than noble gases, with half-lives greater than eight days in gaseous effluents released, from each reactor unit, from the site shall be limited to the following:
a)
During any calendar quarter: Less than or equal to 7.5 mRems to any organ, and b)
During any calendar year:
Less than or equal to 15 mRems to any organ.
b.
Liquid Effluents 1)
The dose or dose commitment to an individual from radioactive materials in liquid effluents released, from each reactor unit, from the site shall be limited:
a)
During any calendar quarter to less than or equal to 1.5 mrem to the total body and to less than or equal to 5 mrem to any organ, and b)
During any calendar year to less than or equal to 3 mrem to the total body and to less than or equal to 10 mrem to any organ, c.
Total Dose 1)
The dose or dose commitment to any member of the public, due to releases or radioactivity and radiation, from uranium fuel cycle sout :.es shall be limited to less than or equal to 25 mrem to the body or any organ (except the thyroid, which shall be limited to less than or equal to 75 mrem) over 12 consecutive months.
t rad / misc /194-93b.wpf 15 of 25
^
EFFLUENT AND WASTE DISPOSAL ~ SEMI-AN:!UAL REPORT (1994)
I e
l Supplemental Information (continued) t 2.
Allowable Concentrations a.
Gaseous Effluents 1)
The dose rate due to radioactive materials released in gaseous effluentt from the site shall be limited to the following:
a)
For noble gases: Less than or equal to 500 mrem / year to the total body and less than or equal to 3000 mrem / year to the skin, and b)
For all radiciodines and for all radioactive materials in particulate form, and radionuclides, other than noble i
gases, with half-lives greater than eight days:
Less than or equal to 1500 mrem / year to any organ via the inhalation pathway.
b.
Liquid Effluents 1)
The concentration of radioactive material released from the site shall be limited to the concentrations specified in 10 CFR Part 20, Appendix B, Table II, Column 2 for radionuclides other than dissolved or entrained noble gases. For dissolved or ent. ined noble gases, the concentration shall be limited to the following:
Nuclide DWC (pci/ml)
Kr-85m 2.00E-04 Kr-85 5.00E-04 Kr-87 4.00E-05 Kr-88 9.00E-05 Ar-41 7.00E-05 Xe-131m 7.00E-04
)
Xe-133m 5,00E-04 Xe-133 6.00E-04 Xe-135m 2.00E-04 Xe-135 2.00E-04 3.
Average Energy i.
Not Applicable.
4.
Measurements and Approximations of Total Radioactivity a.
Gaseous Effluents 1)
Containment Vent and Purge System is sampled by grab sample which is analyzed for principal gamma emitters and H-3.
2)
Main Vent Stack is sampled by grab sample which is analyzed for principal gamma emitters and H-3.
3)
Standby Gas Treatment System is sampled by grab sample which is analyzed for principal gamma emitters.
rad / misc /194-93b.wpf 16 of 25 l
1
EFFLUENT AND f3ASTE DISPOSAL SEMI-ANNUAL REPORT (1994)
's Supplemental Information (continued) 4)
All release types as listed in 1 and 2 above, at the vent stack and as listed in 3 above, at the Standby Gas Treatment System whenever there is a flow, are continuously sampled by charcoal, particulate and composite samples which are analyzed for iodines, principal gamma emitters, gross alpha, Sr-89 and Sr-90.
Noble gases, gross beta and gamma are continuously monitored by noble gas monitors for the vent stack and the standby gas treatment system.
b.
Liquid Effluents 1)
Batch waste release tanks are sampled each batch for principal gamma emitters, I-131, dissolved and entrained noble gases, H-3, gross alpha, Sr-69, Sr-90 and Fe-55.
2)
Continuous releases are sampled continuously in proportion to the rate of flow of the effluent stream and by grab sample.
Samples are analyzed for principal gamma emitters, I-131, dissolved and entrained noble gases, H-3, gross ipha, Sr-89, Sr-90 and Fe-55.
5.
Batch Releases a.
Gaseous 1)
Number of batch releases:
None 2)
Total time period for batch releases:
N/A 3)
Maximum time period for a batch release:
N/A 4)
Average time period for batch releases:
N/A 5)
Minimum time period for a batch release:
N/A b.
Liquid 1)
Number of batch releases:
1 2)
Total time period for batch releases:
Min.
570 3)
Maximum time period for a batch release: Min.
570 4)
Average time period for batch releases:
Min.
570 5)
Minimum time period for a batch release: Min.
570 6)
Average stream flow during periods of release of effluent into a flowing stream:
gpm 5.88E+06 rad / mis c/194-93b. wp f 17 of 25 i
\\
/ '
^
EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1994)
Supplemental Information (continued) i 6.
Abnormal Releases a.
Gaseous 1)
Number of releases:
None 2)
Total activity released:
N/A b.
Liquid 1)
Number of releases:
None 2)
Total activity released:
N/A 7.
There were no changes to the Process Control Program.
e.
Effluent Monitoring Instrumentation timeclocks.
There were no timeclocks for the effluent monitoring instrumentatron exceeded.
E I
r i
1 r
A i
rad / misc /194-93b.wpf 18 of 25 1
- s-
-e EFFLUENT AND UASTE DISPOSAL SEMI-ANNUAL REPORT (1994) 1.
METEOROLOGICAL DATA A
i i
a (See following pages.)
I
?
P i
i 1
I I
rad / misc /194-93b,wpf 19 of 25
)
i
CECO LASALLE 5!AT13 kir5epteser 1994 El ft. V:0 9ED ed V!E DIRECil3 375 33 ft. D!ifRBilAL TDFBATIE EES Of OB58 VAT 135 21D VMS ME PRS DCClEEEE MilliY CLASSE5 - - - --
g[g
........................ M DRKilm CLASSE5 -
CLASS I ME E EE E ESI SE SSE 5 SSV SW V5W V N W N TOTAL EU t 50 R SS MS [5 10iAt l
EU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 m.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 C SU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 A I.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 i
L $5.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 N 6.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 1
E3.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.00 EU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 m.00.00.00.00.00.00.00.00.00.00.05.00.00.00.00.00.05
.05 1 SU.00.00.00.00.00.00.00.5.00.00.00.00.00.00.00.00.05
.05 l
N.09.14.05.00.00.00.05.09.09.00.00.6.00.05
.1.09.82
.82 i
3 55.05.09.05.00.00.05.09.00.05.00.09.05.00.00.05.05.60
.60 E.05.00.00.05.05.00.05.00.09.00.00.00.00.05.00.00.32
.32 ES.00.00.00.00.00.00.00.05.05.05.00.00.00.00.00.00.14
.14 1.97 EU.00.00.05.00.00.00.00.00.00.00.09.00.00.00.00.00.14.14 W.00.09.05.00.00.00.00.05.18.14.09.00.00.14.6.00.82
.82 4 $U.05.18.14.14.14.05.ll.!8.23.05.18.09.18.05.05.00 1.88 1.88 X.37.H.55.09.41.60.69.32.32.D.46.60.41.41.50.P 6.69 6.69 7 55.23.23.05.14.14.14.14.14.09.09.18.00.23.14.14.00 2.06 2.06 5.05.18.14.00.14.14.27.00.M.00.00.09.05.14.00.00 1.19 1.19
[5.18.00.00.00.00.05.00.00.00. 5.00.14.05.00.00.00.46
.46 13.24 (U.00.18.D.00.00.00.00.05.05.09.00.00.00.00.00.00.64.64 N.18.27.D.18.00.00.00.14.50.69.27.37.14.05.00.05 3.07 3.07 8 50.18.18.09.00.00.00.00.18.55.5.18.D.P.32.09.18 2.89 2.89 I.U.60.92.32.D.37.U.D.32.46.46.U.87 1.19.55.69 8.29 8.29 155.18.32.32.00.D.U.18.23.14.18.D.46.27.32.32.00 3.76 3.76 2 E.23.14.00.5.00.23.09.18.18.23.46.32.14.05.U.27 233 2.93 ES.00.05.30.00.00.05.00.18.14.05.23.14.5.09.05.14 1.15 1.15 22.72 (U.00.00.00.00.00.00.00.00.00.23.05.00.00.00.00.00.27.27 1 N.05.09.00.05.09.00.00.00.05.78.50.32.05.00.00.D 2.20 2.20 3 SU.14.05.00.09.18.00.5.00.05.U.46.50.09.00.41.73 3.11 3.11 I.32.37.82.73.73.32.U.41.46.82.55 1.42 1.24 1.51 1.19.82 12.00 12.00 1 55.50. 5.14.5.41.37.U.P.55.78.D.50.18.27.41.55 6.09 6.09 8 E.14.14.00.00.18.55.55.41.37.32.55.!!.37.41 1.33.82 6.55 6.55 ES.09.00.00.00.00.5.05.78.46.D.18.6.14.05.46.18 2.98 2.98 13.21 20 of 25
q i
_y CICo1ASALLE STAT 13 kly-Septaber 19N
-l N5 ft. WlE SPEG ad VIE DIECTIE 375 33 ft. DIREITIAL IDPRATWE j
i SPEG Wie DECT13 CLASES --- - -- --- -- - -- - -- --
--- STMILITY CLASES --- -----
CLASS I E E EE E N E SSE 5 52 2N W N W N TOTAL G W 2 1 55 15 ES TOTAL 0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00. 00 15.00.00.00.00.5.00.00.00.M.5.18.14.00.00.05.09
.H
.64 9 2.00.00.00.00.00.00.00.00.00. 5.09.05.14. 5.32. 5.73
.73 i
I.18.09.5.5.09.18.2.32.H 1.01.50.3
.78.09.41.32 5. 2 5.9 2 55 E.18.00.5.23.23.50.55.H E.H.50 E.32.32.37 5.36 5.36 i
4 E.23.5.00.00.00.14.14.18.41.4.4.55.18.23.27.00 3.30 3.30 ES.00.18.00.00.00.00.18.32.4.18 3.4.14.00.M.00 2.38 2.38 18.09 i
9.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 6 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 T 2.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 I.00.00.00.00.00.09.05.00.05 E.00.M.18.00.05.00.78
.78 2 $$.5.14.00.00.09.00.18.32.181.19 1.05.32.05.23.00.00 3.80 3.80 4 E.09.00.00.00.00.14 E.00.461.24 IS.14.09.14.00.00 4.54 4.54 ES.00.00.00.00.00.00.5.5.27.55.4.27.00.00.00.00 1.6 1.5 10.H i
T014.26 4.67 3.89 IS 3.39 4.08 5.36 5.U 8.1111.4111.27 9.30 6.64 6.28 7.60 6.00100.001.05 6.78 8.66 34.26 21E 18.83 8.75 100.00 -
Vind Directie by Stability I E E EE E ESE SE SSE 5 SW 2N W W W N TOTAL STMILITY CLASSES-
.00.18.32.00.00.00.00. 5 5.32.14.00.00.00.00.00 1. 5 Extreely htable
.23. 4.27.23.14.00.00.18.82 1.65 1.10.82.18.18.14 3 6.78 bderately htable J.41.23.23.32.5.23.41 R.73.92.92.78.41 5.N B.66 Slightly htable 1.33 1.56 2.38 1.19 1,47 1.56 2.02 1 3 1.88 2.79 I S 2.93 3.48 3.25 2.79 2.29 34.26 letral 1.28 1.33.55.23 1.10 1.15 14 1.60 1.5 2.52 24 1.83 1.01 1.28 1.24.96 21R Slightly Stable
.78.50.14.5.N 1.1913.781.512.N 3.441.51.82 !.01 IS 1.1018.83 hhrately Stable E.23.00.00.00.14 E 1 N 131.151.241.28 3.14.60.32 8.75 Extratly Stable Vind Direction by Wind Speed r
i K E EE E ESE SE SSE 5 52 2N W N W N TOTAL -115 SPED CLASSES-
.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 CAlI
.18.23.09.5.5.5.18.18.27.5.14.14.00.M.14.14 IS 0.8 3.5 $
E 1.5.96.N.82.N 1.25.H &.551.01.92.92 R.78 313.N 3.6 7.5 d 1.151.7414.55.461.01.H 1.191.88 IS 1.831.921.83 2.02131.33 22.72 7.6 12.5 W l.N 1.01.96.921.601.281.51515 3S 2S 3.44 2.06 2.24 3.80 3.34 33.!!
!!.6 - 18.5 W
.H.50.5.5 3.51.4213 2.N 2.02 2.M 2.061.51.6514 R 18.M 18.6 24.5 W
.14.14.00.00.09.23.55 3.96 3.25 3.48 R.32 3.5.00 10.H
> N.5 $
21 of 25
ECalASALLE $1 Ail 3 Octate-Decaber 1994 375 ft. VIE PEG ad VIE O!BEUl3 375-33 ft. OlffEBTIAL IDFRATf!
4 t
WER Of 062All35 = 215 VALUES ME BEXT OfMEI VIO DIR!tT104 CLASSE5 -
- --- --- STElllTY CLASSES yED GA55 i ME E EE E ESE SE SSE 5 55W SW F V M W W TOTAL EU t 50 1 55 E ES TOTAL B.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 m.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 C 50.00.00.00.00.00.00.00.A.00.00.00.00.00.00.00.00.00
.00 A R.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 L 55.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 N E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.00 EU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 t.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 1 50.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 X.00.05.00.05.00.09.05.05.05.05.00.00.00.00.00.05.41
.41 3 55.05.05.14.18.09.00.09.00.05.00.05.09. 5.05.00.00.92
.92 5.00.00.00.00.00.00.05.00.00.00.00.00.00.00.09.00.14
.14 ES.00.00.00.00.00.00.00.00.00.00.09.00.09.00.00.00.18
.18 1.65 EU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 m.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 4 SU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
- h.46.46.41.U.09.32.32.18.14.27.18.05.05.U.09.46 4.03 4.03 7 55.14. 5.14.09.18.04.18.05.14. 5.14.05.09.09.14.09 1. 0 1.0 6.00.00.00.00.09.23.09.05.00.14.09.09.09.00.09.05 1.01 1.01 (5.00.00.00.00.00.00.00.04.09. 5.00.00.04.05.00.09
.D
.27 7.00 B.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 t.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 8 SU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 t.50 1.01.78.6.82.55.64.18.05.73.D.18.14.U l.14 1.28 9.20 9.20 1 55.50.55.82.41.37.46.32.05. 5.00.18.05.46.18.18.09 4.67 4.67 2 E.05.18.D.00.05.23.14.14.05.05.05.09.00.5.11.23 1.0 1.0 ES.00.00.00.00.00.00.00.00.14.14.5.05.00.00.18.14
.0
.0 16.25 EU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 1 E.00.00.00.05.00.00.00.00.00.00.00.00.00.00.00.00.05
.05 3 SU.00.00.00.09.00.00.00.00.00.09.00.00.00.00.00.00.18
.18 I.78.37 1.78.59 1.05.78.23.32.46.82.59.14.50.96 1.60 1.33 12.31 12.31 155.55.41.41.41.64.14.23.D.18.50.32.23.41.55.73.32 6.32 6.32 8 E.09.6.32.05.00.18.D
.0"
.14.18.5.18.18.18.23.D 2.61 2.61 ES.00.00.00.00.00.00.05.14.18.18.05.05.05.00.00.09.7!
.78 22.24 22 of 25
~
EEE0 LASALLE STAT 13 Octder Deteder 10 375 ft. VIE SPEB am!V!E 01ECil5 375 33 ft. OlfflitEFIAL TERRATJtE 1
SPEB - - -....- -- ----- --- -- VIE DIRECHON CLASSE5 --- -- - - ---- -- --- -- -
-- - -. U2ll!TY CLA55!$ - -----
CIA 55 X K FT E ESE SE SSE 5 SW WH W N N N TOTAi. G E 2 i SS E E5 TOTAL i
G.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 1 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 9 SU.00.00.00.00.14.00.00.00.00.00.00.00.M.5.00.00.27
.27 I.18.32.D 1.4 1.10.4.41.50 1.01 1.14.6.37.50 1.42 1.24.4 11.99 11.99 2 55.00.18.05.41.H 1.10.2.32.92.D.50.09.4.41.37.18 6.86 6.86 4 E.23.00.00.M.27.41.U.14.18.14.23.05.55.59.32.09 3.f.6 3.66 ES.00.00.00.00.00.00.09.27.37.18.37.14.05.05.00.41 1.92 1.92 24.11 5.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 6 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 12.05.5.00.05.00.00.00.00.00.00.00.00.05.M.00.00
.H
.27 I.18. 5.14.32 1.05.18.00. 9.82 1.19.32.92.92.64.87.14 8.10 8.10 2 55.09.00.00.D.50.41.9.87 1.83 3.20 1.4.U l.37.78.32.5 12.17 12.17 4 6.00.00.00.00.5.9.18.18.82 1.19.96.H.E.32.05.00 5.13 5.13 E5.00.00.00.00.00.5.27.55.50.18.32.23.18.14.00.5 2.47 2.47 28.15 TOT 3.84 3.98 5.95 5.49 7.19 6.36 5.03 4.718.1511.216.913.48 6.86 7.14 7.0 ! 86100.00.00.05.D H.04 32.6314.23 6.32100.00 Vim!Directia by 5tdility i E E EE E ESE SE SSE 5 SW WG V N N N TOTAL -SiA61t!1Y CLASSES-
.00.00.00.00.00.00.00 00.00.00.00.00.00.00.00.00
-.00 Extreely hstdle
.00.00.00. 5.00.00.00.00.00.00.00.00.00.00.00.00
.5 Werately hstdle
. 5. 5.00.14.14.00.00.00.00.09.00.00.14.14.00.00.73 511ptly hstdle 2.11 2.24 3.84 3.39 4.12 2.38 1.6 1.60 2.52 4.21 2.01 1.E 2.11 3.57 4.H 3.H 4.H betral 1.33 1.24 1.56 1.78 2.43 2.20 1.92 1.56 3.16 4.49 2. 6.87 2.88 2.06 1.74.78 32. 0 511$tly Stele
.U.4.E.14.9 1.74 1.05.H 1.19 1.69 1.U.50 1.9 1.14.96.59 14.23 bderately Stdie
.00.00.00.00.00.05.41.96 1.28.73.87.4.U.23.18.78 6.32 Extremly 5ttle lim!Directia by Wimf Speed i E E DE E ESE SE 55E 5 SW WG W N W N TOTAL -VIE SPEB CLASSES-
.00.00.00.00 00.00.00.00.00.00.00.00.00.00.00.00.00 CALM
.5.09.14.23.09.09.18.05.5.5.14.5.18.5.09.5 1.E 0.8 3.5 W
.59.2.5.37.9.64.9.H.37.50.41.18.23.41.32.9 7.00 3.6 7.5 W l.05 1.74 1.0 1.10 1.24 1.24 1.10.9.D.92.50.U.59.50 1.H 1.74 16.25 7.6 12.5 $
1.42 1.05 2.52 1.19 1.0 1.10.D.82.96 1.78 1.01.59 1.14 1.0 2.56 1.9 22.24 12.6 - !!.5 W
.41.2.78 1.9 2.15 1.97 1.N 1.24 2.47 2.20 1.78.64 1.0 2.52 1.92 1.14 24.H 18.6 - 24.5 W
.32.5.14.64 1.6 1.33 1.05 1.57 3.98 5.D 3.07 1.60 3.07 1.9 1.24.D 28.15
> 24.5 W 23 of 25
~
,i e
' FAILURE TO PERFORM THE MONTHLY SOURCE CHECK OF THE OFFGAS PRETREATED LOG AND LINEAR fliOCESS RADTXTION MONITOR ON TIME DESCRIPTION AND CAUSE OF EVENT:
A monthly source check of the OFFGAS (0/G) pretreat log and linear process radiation monitor (PRM) was performed late. This source check is required to be performed once every 31 days.
This surveillance is performed by the Radiation Protection Department (RPD), using the General Surveillance Tracking Program (GSRV) printout as a schedule.
In the latter part of August 1994, the GSRV printout format for the RPD was changed. The change that occurred was the GSRV printout to the RPD would be a single printout and would include all of the Health Physics (HP) surveillances, and the HP Department surveillances.
Prior to this change there were two printouts, an HP printout and an HPD printout. The HPD printout contained all the RPD surveillances. This printout was approximately five pages in length and would include the surveillances for the O/G protreat log and linear RPMs. These surveillance are unit specific, that is listed by each unit specifically, Unit 1, Unit 2 or Unit 0.
Unit 0 is used to indicate the surveillance applies for both Unit 1 and Unit 2.
The HP printout contained all the surveillances due on the RPD instruments. This printout for a six week period is approximately 50 pages in length. These items would be associated with Unit 0 since they are performed for both Unit 1 and Unit 2.
When both GSRV and Electronic Work Control System (EWCS) reports were combined, the resulting printout was approximately 55 paces in length. The first 50 pages being Unit 0 surveillances, and the last five pages being specific to Unit 1 and Unit 2 surveillances.
All GSRV/EWCS surveillance printouts are unit specific and in date due order.
All the items are printed first in date due order specific to Unit 0, then items for Unit 1 are printed in date due order, and tinally items for Unit 2 are printed in date due order. The RP Department GSRV Coordinator only went through the first 40 pages of the GSRV to sign off the required items.
He was unaware that the GSRV/EWCS paperwork had been changed and the last five pages of the teport were specific surveillances for Unit 1 and 2.
- On September 20, 1994 it was discovered that the monthly source check of the O/G pretreat log and linear PRMs had not been performed. The monthly source check was immediately scheduled, and on September 26, 1994 both units passed satisfactorily. The missed surveillance for the monthly source check should have been performed within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> once it was discovered that it had been missed.
I i
i rad / misc /194-93b.wpf 24 of 25
e 9
a CORRECTIVE ACTIONS:
l'.
The monthly source check was immediately scheduled, and on September 26, 1994 both units passed satisfactorily.
(This item is complete).
2.
Revise the current ODCM to provide specific guidance concerning any missed surveillances.
Action Item Record ( AIR) 373-200-94-0215401 has been generated and will track completion of the ODCM revision.
The AIR due date is July 15, 1995, this item will be completed then.
3.
Include this event and investigation in the next Semiannual Effluent Report.
Action Item Record (AIR) 373-200-94-0215402 has been generated and will track completion of this commitment.
Submission of this report will complete this item.
4.
A memo was generated November 11, 1994 to communicate this event and the revised GSRV/EWCS format to the personnel in each department responsible for GSRV surveillance tracking.
(This item complete).
rad / misc /194-93b.wpf 25 of 25