LASALLE em
1.0 INTRODUCTION
The following constitutes the current,1996 Monthly Progress Report for the Radiological Environmental l
Monitoring Program conducted at the LaSalle County Station, Marseilles, Illinois. Results of completed analyses are presented in the attached tables. Missing entries indicate analyses that are not completed and the results will appear in subsequent reports.
Missing tables indicate sample media scheduled for collection at a future date. Tables will appear in subsequent reports.
Data obtained in the program are well within the ranges previously encountered in the program and to be expected in the environmental media sampled.
For all gamma isotopic analyses, spectrum is computer scanned from 80 to 2048 kev. Specifically included are Mn-54, Fe-59, Co-58, Co-60, Zn-65, Zr-95, Nb-95, Ru 103, Ru 106,1-131, Ba-La-140, Cs-134, Cs-137, Ce-141, and Ce-144. Naturally occurring gamma-emitters, such as K-40 and Ra daughters, are frequently detected but not listed here. The data is reported in the format of x12s;2TPU, where "x" is the significant result, "s" is the one standard deviation counting uncertainty, and TPU is the total propagated uncertainty at the one sigma confidence level.
Locations denoted by a "(C)" after si:e code refer to controllocations.
l All concentrations, except gross alpha and beta, are decay corrected to the time of collection.
t
.V TLD data is provided by Commonv ealth Edison Company.
Deviations from Scheduled Sampling and Corrective Actions Taken All samples were collected within the schedu'ed period unless noted otherwise in the Listing of Missed Samples.
Unusual Environmental Measurements L cation Collection Sample Type Comments Code Date A(V t
IV 9709030160 970829 PDR ADOCK 05000373 R
LASALLE 2.0 SIATION ACTION ITEMS Item Problem Recommend (d Solution 1on car None 12/%
O O
LASALLE 3.0 LISTING OF hilSSED SAh1PLES 1 ocation ExmW Sample Type Collection Reason gg Date hil L-41 01 02-96 Cow is in calf.
SW L-40 01-09-96 River is frozen.
SW L-21 01-30-96 Riser is frozen.
SW L-21 02 06 96 River is frozen.
SW L-40 02-06-96 Riser is froren, hil L-41 02-06-96 Cow is in calf.
hil L-41 03-05-96 Cow is in calf, hil L-41 (M 02-96 Cow is in calf, hil L-41 05-07-96 Cow is in calf, hil L-41 05 21 96 Cow is in calf.
Nil L-41 064M 96 Cow is in calf.
[
hil L 41 06-18 96 Cow is in calf.
hil L-41 07 02 96 Cow is in calf.
SW L40 07-23-96 Access to sampling location restricted by thul waters.
hil L-41 07-30-96 Cow is in calf, hil L-41 08 13 96 Farmer requested to be remosed from program.
O t
vi
LASALLE 4.01.lSTING OF SAMPLE ANOMAllES Location Collection Sample Typ Reason C<xle Date M
L 10 01-02 96 Pump malfunction; installed replacement pump.
M L-03 05-14-96 Final Dowrate outside 109i; checked reputator and flowmeter; no problems discoscred.
M L-05 06-11 96 Final flowrate outside 109: checked regulator and nowmeter; no problems discoscred.
M L-03 07 23-96 Pump malfunction;installei, placement pump.
M L-06 07-30-96 Pump found off due to blown fuse; fuse replaced.
M L-03 10-01 96 Low Vmax; sample collector will check pauge and replace on 10/8/96, if necessary.
M L-05 10-29-96 Actual now high; no reason apparent TLD Other i1-05-96 Monthly sisual check - Unable to verify #305, LaSalle Lake, due to locked gate. Verified on Il-12 96.
TLD Other 12 31 96 L-305-1, gate locked. TLD given to T. Gibes at LaSalle
(
station for placement.
O
LASALLE Table 1.
Airborne Particulates and lodine I 131 Collection:
Continuous; weekly exchange Required LLD: Gross Beta = 0.01,1131 = 0.07 pCl/m' 4
Units:
10 pCi/m' L 01 Nearsite No.1 Date Volume Gras Date Volume Gross Collected (m')
Beta 1131 Collected (m')
Heta 1131 01-02 96 286 2.410.3;0.5
-0.711.8:1.8 07-02-96 296 2.410.3;0.5
-0.610.9;0.9 01-09-96 285 2.910.3;0.6 0.5 i 1.3;1.3 07-09 96 284 2.310.3;0.5 0.2 - 0.8;0.8 01 16-96 276 3.410.4;0.7 2.0 i 1.3;1.3 07 16-96 284 1.9 0.3; 0.5
-0.511.5;1.5 01 23 96 286 2.110.3;0.5 0.411.1;1.1 07 23 96 286 1.510.3;0.4 0.510.9;0,9 01 30-96 290 2.110.3;0.5 0.5 i 1.6; 1.6 07 30-96 290 1.4 0.3; 0.4 0.210.9;0.9 02-06-96 287 3.5 i 0.4 ; 0.7 1.011.3;1.3 08-07-96 334 2.0: 0.3; 0.5
-0.0 0.6; 0.6 02-13 96 283 1.810.3;0.4 0.210.9;0.9 08-13-96 241 2.1 0.3; 0.5 0.4 1.2; 1.2 02-20-96 285 1.510.3;0.4 0.110,9;0.9 08 20-96 288 2.2 0.3; 0.5 0.611.9;1.9 02 27 96 286 1.810.3;0.4 0.210.5;0.5 08-27-96 284 2.6 03;0,6
-0.2 0.9:0.9 03-05-96 291 2.010.3;0.5 0.211.2;1.2 09-03-96 286 3.410.4;0.7
-0.911.5;1.5 03 12-96 278 2.110.3;0.5 1.011.5;1.5 09-10-96 286 4.210.4;0.8
-1.I 1.2;1.2 03 19-96 293 2.5 i 0.3; 0.5 0.211.5;1.5 09 17 96 286 1.6 0.3 ; 0.4
-0.210.8;0.8 03-26-96 278 1.810.3;0.4 0,410.8;0.8 09-24-96 286 2.5 0.3 ; 0.6 0.3 1.0; 1.0 1st Qtr. hicanis.d. 2.310.6 0.310.7 3rd Qtr. hicanis.d. 2.3 0.8 0.210.5 04-02 96 295 1.710.3;0.4
-0.611.7;1.7 10-01-96 297 2.510.3;0.5 2.1 2.2 ; 2.2 04 09-96 279 2.0 i 0.3; 0.5
-0.211.0;1.0 10-08-96 284 2.2 0.3; 0.5 1.0 1.1 ; 1.1 04 16 96 283 1.410.3;0.4 0.511.2;1.2 10-15-96 286 2.3 0.3 : 0.5
-0.5 1.2; 1.2 04-23-96 285 1.210.3;0.4
-0.111.5;1.5 10-22 96 287 2.820.3;0.6 0.4 1.81.8 30-96 285 1.0 0.3; 0.3 0.9 i 1.1 ; 1.1 10 29-96 296 2.110.3;0.5 2.712.1;2.2 05-07-96 294 1.710.3;0.4
-0.611.0;1.0 11-05-96 287 2.410.3;0.5
-0.4 1.4 ; 1.4 05-14 96 287 1.7103;0.4 0.310.9;0.9 11-12-96 291 2.0 0.3; 0.5 0.2 1.4 ; 1.4 05-21 96 282 1.8i0.3;0.4
-0.2 i 1.1 ; 1.1 11 19-96 279 2.9 0.3; 0.6
-0.3 1.0; 1.0 05-28-96 290 1.7i0.30.4 1.5 1.4 ; 1.4 11 26-96 284 1.7 0.3; 0.4
-0.2 1.4 ; 1.4 06-04-96 290 1.210.3;0.3
-0.5 1.2; 1.2 12-03-96 287 2.5 0.3; 0.6
-0.3 1.5 ; 1.5 06-11-96 285 0.610.2;0.3 0.510.8;0.8
.12 10-96 286 2.5 0.3; 0.6 1.612,7;2.7 06-18 96 285 2.310.3;0.5 0.111.1;1.1 12 17-96 286 2.2 0.3; 0.5 0.2 1.3; 1.3 06-25-96 282 1.810.3;0.5
-0.310.9;0.9 12-24-96 283 2.4 0.3; 0.5 0.5 1.0; 1.0 2nd Qtr. hicanis.d. 1.6i0.5 0.110.6 12-31-96 290 4.1 0.4 ; 0.8 0.2 1.0; 1.0 4th Qtr. hiean s.d.
2.5 0.5 0.511.0 0
1-1
LASALLE Table 1.
Airborne Particulates and lodine 1131 Collection:
Continuous: weekly exchange Required LLD. Gross Beta 0.01, I 1'u = 0.07 pCi/m' Units:
10' pCi/m' L-03 Onsite No. 3 Date Volume Gnws Date Volume Gnw.s Collected (m';
Deta 1-131 Collected (m')
Deta 1-131 01-02 96 287 2.2 0.3; 0.5 0.111.1;1.1 07-02-96 287 2.1 i 0.3; 0.5
-0.121.9;1.9 OI-09-96 279 2.710.3;0.6 0.3 i 1.1 ; 1.1 07-09 96 288 2.3 i 0.3; 0.5
-0.221.5;1.5 01 16 96 281 3.510.4;0.7 0.2 i 1.5 ; 1.5 07-16-96 284 1.9 0.3; 0.5 0.1 1.5 ; !.5 01-23-96 279 2.210.3;0.5
-0.2 1.6;1.6 07 23 96 143 1.1 -t 0.5; 0.5
-0.5 2.1 ; 2.1 01-30-96 305 2.0 0.3; 0.5 0.110.7;0.7 07-30-96 285 1.7 0.3; 0.4
-0.3 05;0.5 02-06 96 282 3.610.4;0.8
-0.311.4;1.4 08-07-96 334 2.0 0.3 ; 0.5
-0.1 1.5;1.5 02 13 96 283 3.3 0.4;0.7
-0.2 0.7;0.7 08-13-96 236 1.7 0.3; 0,4 0.9 0.9 ; 0.9 02 20-96 285 1.810.3;0.4 0.810.9;0.9 08-20 96 283 2.4 0.3; 0.5
-0.5 1.1;1.1 l
02 27-96 286 1.8 0.3; 0.5
-0.110.5;0.5 08-27-96 284 2.6 0.3; 0.6 1.0 1.3;1.3 l
03-05-96 285 2.210.3;0.5
-0.211.2;1.2 09-03-96 287 3.410.4;0.7 0211.3;1.3 03-12-96 280 2.310.3;0.5
-1.0 i 1.6; 1.6 09-10-96 286 3.2
- 0. 4 ; 0.7 0.4 1.1;1.1 03-19 96 289 2.010.3:0.5 0.3 0.8;0.8 09-17 96 281 1.7 0.3; 0.4
-0.1 i 1.3; 1.3 03-26-96 275 1.6 0.3; 0.4 0.0 0.8 ;0.8 09-24-96 286 2.510.3;0.6
-0.3 1.1 ; 1.1 ist Qtr. hicanis.d. 2.410.7
-0.110.4 3rd Qtr. hieants.d.
2.20.6 0.00.5 04 02-96 290 1.910.3;0.5
-0.2 i 0.6;0.6 10-01-96 290 2.7 0.3 ; 0.6
-0.2 2.2 ; 2.2 04-09-96 280 1.810.3;0.4
-0.2106;0.6 10-08-96 276 2.2 0.3 ; 0.5 1.0 1.2 ; 1.2 04-16-96 286 1.4 i 0.3; 0.4
-0.5 1.2; 1.2 10-15-96 295 2.4 0.3 ; 0.5
-0.9 1.2 ; 1.2 04 23 96 285 1.4 0.3 ; 0.4
-0.411.5;1.5 10-22-96 2S7 0.6 0.2 ; 0.2
-0.7 1.7;t.7 04-30-96 280 0.7 0.3; 0.3
-0.611.1;1.1 10-29-96 286 2.1 0.3; 0.5 0.4 1.1;1.1 05 07-96 294 1.7 0.3; 0.4 0.5 1.1;1.1 11-05 96 280 2.4 0.3; 0.5 0.4 1.4 ; 1.4 05-14 96 248' 1.210.3;0.4
-0.5 i 1.2; 1.2 11-12-96 291 2.0 0.3; 0.5 0.810.7;0.7 05-21-96 279 1.7 0.3 ; 0.4 0.721.4;1.4 11-19-96 279 2.110.3;0.5
-1.5 1.1;1.2 05 28-96 294 1.5 0.3; 0.4 0.5 1.0; 1.0 11-26-96 284 1.3 03;0.4
-0.9 1.6;1.6 06-04 96 286 1.410.3;0.4 0.711.3;1.3 12-03-96 287 2.4 0.3; 0.6
-0.221.S;1.8 06-11-96 285' O.8 0.2; 0.3 0.5 1.1 ; 1.1 12 10-96 285 2.4. 0.3; 0.5
-0.1 2.3; 2.3 06-18-96 285 2.110.3;0.5 0.7 0.9:0.9 12-17-96 286 1.9 0.3; 0.5 0.4 0.7;0.7 06-?496 292 1.6 0.3; 0.4
-0.3 1.1;1.1 12-24-96 281 2.3 0.3 : 0.5 0.4 1.0 ; 1.0 2nd Qtr. hiean s.d.
1.510.4 0.1 0.5 12-31-96 288 2.8 0.3 ; 0.6
-1.3 1.1 ; 1.1 4th Qtr. hiean s.d.
2.1 0.6
-0.2 0.8
' Final flowrate outside 10%; checked regulator and flowmeter; no problems discovered.
1-2
LASALLE Table 1.
Airborne Particulates and lodine 1131
(
Collection:
Continuous; weekly exchange Required LLD; Gross Beta = 0.01 !.131 = 0.07 pC n'
4 Units:
10 pCi/m
L-05 Onsite Station No. 5 Date Volume Gross Date Volume Gnw.
Collected (m')
Beta I-131 Collected (m')
Deta 1-131 01-02 96 287 2.8 i 0.3; 0.6
-0.211.7;1.7 07 02 96 292 2.010.3;0.5
- 0.1 0.8;0.8 01-09-96 283 2.710.3;0.6 0.5 i 1.3; 1.3 07-09 96 282 1.8 0.3; 0.5
-0.5 1.4 ; 1.4 01 16-96 276 3.510.4;0.7
-0.2 1.2 ; 1.2 07-16-96 284 2.0 0.3; 0.5 0.3 1.6; 1.6 01 23 96 270 1.710.3; C.4 0.5i1.31.3 07 23-96 286 1.6 0.3; 0.4 0.011.0;1.0 01-30 96 285 1.9 i 0.3;0.5
-0.7 i 1.9; 1.9 07-30-96 285 1.810.3;0.4
-0.2 1.3; 1.3 02-06 96 287 2.1163;0.5 0.210.7;0.7 08-07-96 328 2.0 0.3; 0.5 0.5 1.4 ; 1.4 l
02 13 96 283 1.310.3;0.4 0.1 i 0.8;0.8 08-13-96 236 1.7 0.3; 0.5
-0.211.5;1.5 02-20-96 285 1.510.3;0.4 0.3 i 1.2;1.2 08-20-96 288 2.410.3;0.5 1.411.9;2.0 02 27-96 286 1.710.3;0.4
-0.110.4;0.4 08-27-96 284 2.410.3;0.5
-0.2 t 0.6;0.6 03-05-96 284 2.010.3;0.5 1.5 i 1.2;1.3 09-03-96 287 3.0 1 0.4; 0.7
-0.111.4;1.4 03-12-96 286 2.0 i 0.3; 0.5 0.311.5;1.5 09-10-96 286 3.9 0.4 ; 0.8 1.3 i 1.3; 1.3 03-19-96 288 2.110.3;0.5 0.610.9;0.9 09-17-96 285 2.0 0.3; 0.5 0.8 1.5;1.5
,\\ 26-96 275 1.210.3;0.3 0.310.8:0.8 09 24-96 286 2.4 1 0.3; 0.5 0.8 1.1 ; 1.1 1st Qtr. Meants.d. 2.010.6 0.210.6 3rd Qtr. Meants.d. 2.210.6 0.30.6 04-02-96 282 1.610.3;0.4 0.2 i 1.3; 1.3 10-01 96 288 2.5 0.3; 0.5 1.6 2.2; 2.2 04 09 96 282 1.910.3;0.5 0.110.9;0.9 10-08-96 283 1.8 0.3;0.5 0.2 1.1;1.1 04 16-96 283 1.S i 0.3; 0.4 1.3 1.2;1.2 10 15-96 286 2.4 0.3; 0.5
-0.411.1;1.1 04-23 96 285 1.510.3;0.4 0.211.1;1.1 10-22-96 292 2.8 0.3; 0.6 1.1 1.7; 1.7 04-30 285 0.910.3;0.3
-0.6 t 1.3;1.3 10-29-96 310 2.510.3;0.5 0.111.6;1.6 05-07-96 294 1.910.3;0.4
-0.2 i 1.0; 1.0 11-05-96 279 2.5 0.3; 0.6 1.0 1.1;1.2 05 14 96 272 1.2 i 0.3; 0.4
-0.611.3;1.3 11-12-96 286 2.0 0.3: 0.5 0.8 1.7;1.7 05 21-96 283 1.9i0.3;0.5 0.611.1;1.1 11-19-96 279 2.7 0.3; 0.6
-0.9 1.4 ; 1.4 05-28-96 290 1.5 0.3; 0.4 0.1 i 1,1 ; 1.1 11 26-96 284 1.610.3;0.4
-0.411.4;1.4 06 04-96 286 1.710.3;0.4
-0.7 1.3; 1.3 12-03-96 287 2.3 0.3; 0.5 1.2 2.0; 2.0 06-11-96 260' O.7i0.3;0.3 0.510.6;0.6 12-10-96 286 2.5 0.3; 0.5
-0.5 2.6;2.6 06-18-96 284 1.9 0.3; 0.4
-0.511.1;1.1 12-17-96 286 2.3 0.3; 0.5
-0.9 1.3; 1.3 06-25-96 282 1.510.3;0.4
-0.2 i 1.1 ; 1.1 12-24-96 301 2.410.3;0.5 0.3 0.9;0.9 2nd Qtr. Mean s.d.
1.510.4
-0.0 0.6 12-31-96 282 3.4 0.4;0.7
-0.211.2;1.2 4th Qtr. Mean s.d.
2.40.4 0.20.8 h
' Final flowrate outside 10%; checked regulator and flowmeter; no problems discovered.
\\
1-3 I
LASALLE Table 1.
Airborne Particulates and lodine 1131 Collection:
Continuous; weekly exchange Required LLD: Cross Beta = 0.01,1131 = 0.07 pCi/m' 4
Units:
10 pCi/m' L-06 Nearsite No. 6 Date Volume Gna Date \\'olume Gnw Collected (m')
Deta 1-131 Collected (m')
Peta 1-131 01-02-96 281 3.010.3;0.6
-0.611.3;1.3 07-02-96 286 1.9 0.3; 0.5 0.7 1.0; 1.0 01-09-96 285 3.0 0.3; 0.7 1.0 1.2 ; 1.2 07-09-96 284 2.0 0.3 ; 0.5 0.5 1.3 ; 1.3 01 16-96 281 2.9 i 0.3; 0.6 0.211.5;1.5 07-16-96 2S4 2.010.3;0.5 1.8 1.5;1.5 01-23-96 285 2.0 t 0.3; 0.5
-1.1 1.2 ; 1.2 07-23-96 284 1.4 0.3; 0.4 0.6 0.9;0.9 01-30-96 295 2.010.3;0.5 0.2 i 1.1 ; 1.1 07-30-96 135 3.3 0.6; 0.9
-0.5 1.3;1.3 02-06-96 292 4.010.4;0.8 0.211.3;1.3 0S-07-96 324 1.8 0.3; O 4 1.0 1.5;1.5 02 13-96 283 1.810.3;0.4
-0.3 0.8 ;0.8 08-13-96 236 1.910.3;0.5 0.5 1.9; 1.9 02 20-96 280 1.410.3;0.4
-0.111.1;1.1 08-20-96 288 2.1 0.3; 0.5
-0.9 2.1 ; 2.1 02-27-96 286 1.510.3;0.4
-0.210.6;0.6 08-27-96 284 2.8 0.3; 0.6 0.3 1.2 ; i.2 03-05-96 291 2.3 0.3 ; 0.5 0.2 1.2;1.2 09 03-96 286 2.8 0.4 ; 0.6 0.2 1.1;1.1 03 12 96 293 2.210.3;0.5 0.610.7;0.8 09-10-96 286 3.8 0.4 ; 0.8
-0.3 1.2,1.2 03-19-96 302 2.210.3;0.5 0.6 i 1.3; 1.3 09-17-96 286 1.7 0.3; 0.4
-0.3 0.7 ; 0.7 03-26-96 269 1.910.3;0.5
-0.310.5;0.5 09-24-96 283 2.7 0.3; 0.6 0.0 ! 1.1 ; 1.1 1st Qtr. Mean s.d.
2.310.7 0.010.6 3rd Qtr. Mean s.d.
2.3 0.7 0.310.7 04-02 96 290 1.810.3:0.4 0.110.6;0.6 10-01-96 291 2.3 0.3 ; 0.5
-3.1 3.0; 3.0 04-09-96 284 1.8 i 0.3; 0.4
-0.111.6;1.6 10-08-96 280 2.0 t 0.3; 0.5 0.8 1.2 ; 1.2 04-16-96 278 1.3 0.3; 0.4 0.6 1.3; 1.3 10-15-96 286 2.3 0.3; 0.5
-0.9 1.2 ; 1.2 04-23-96 281 1.310.3:0.4
-0.8 i 1.6; 1.6 10-22-96 287 2.9 0.3; 0.6 3.1 1.6; 1.7 04-30-96 285 0.9 0.3; 0.3 0.3 1.1;1.1 10-29-96 286 2.1 0.3; 0.5 0.1 0.90.9 05 07-96 294 1.5 0.3 ; 0.4
-0.1 1.0;1.0 11-05-96 292 2.2 0.3 ; 0.5
-0.1 1.4 ; 1.4 05-14 96 282 1.2 0.3; 0.3
-0.4 1.1;1.1 11-12-96 296 2.0 0.3;0.5 0.3 0.S;0.8 05-21-96 273 1.910.3;0.5
-0.1 1.5 ;1.5 11-19-96 284 2.510.3;0.6 0.I 1.1;1.1 05-28-96 290 1.2 0.2 ; 0.3 0.3 i 1.3; 1.3 11 26 96 2S4 1.4 0.3 ; 0.4
-0.5 1.6;1.6 06-04-96 2S5 1.410.3;0.4 0.5 1.0; 1.0 12-03-96 287 2.5 ! 0.3; 0.6
-1.9 2.0; 2.0 06-11-96 285 0.8 0.2 ; 0.3 0.3 1.0; 1.0 12-10-96 286 2.2 1 0.3; 0.5
-0.1 2.6 :2.6 06-18-96 285 2.2 0.3; 0.5 1.0 1.2; 1.2 12-17-96 286 2.5 0.3 ; 0.6
-0.5 1.3;1.3 06-25-96 283 1.6 0.3; 0.4
-0.7 1.0; 1.0 12-24-96 286 2.1 0.3 ; 0.5 0.1 0.9; 0.9 2nd Qtr. Mean s.d.
1.510.4 0.1 0.5 12-31-96 285 2.9 0.3; 0.6
-0.6 1.2 ; 1.2 4th Qtr. Mean s.d.
2.30.4
-0.2 1.4
\\
1-4
LASALLE Table 1.
Altborne Particulates and lodine 1-131 Collection:
Continuous; weekly exchange Required LLD: Gross Beta = 0.01,1131 = 0.07 pCi/m' 4
Units:
10 pCi/m' L-10 (C) Streator Date Volume Cross Date Volume Gnu Collected (m')
Beta 1 131 Collected (m')
Beta 1-131 01 02 96 144* 1.710.4;0.5 1.513.4;3.4 07 02-96 294 2.3 0.3; 0.5 1.011.9;1.9 01-09-96 282 2.710.3;0.6 0.0 i 1.3;1.3 07 09-96 280 2.310.3;0.5
-1.4 1.6; 1.6 01 16-96 286 3.510.4;0.7 0.611.3;1.3 07-16-96 284 2.2 0.3; 0.5 1.5 1.4 ; 1.4 01 23-96 285 2.110.3;0.5
-0.111.7;1.7 07-23-96 286 1.410.3;0.4 0.9 1.0; 1.0 01 30-96 291 1.910.3;0.4 0.212.2;2.2 07 30-96 280 1.6 i 0.3; 0.4 0.411.6;1.6 02 06-96 282 3.210.4;0.7 0.110.8;0.8 08-07-96 334 1.9 0.3 ; 0.4 0.1 0.8;0.8 02 13-96 283 1.910.3;0.4 0.210.6;0.6 08 13-96 237 1.910.3;0.5
-0.3 1.0; 1.0 l
02 20-96 285 1.610.3;0.4
-0.811.1;1.1 08 20-96 281 2.6 0.3: 0.6 0.111.4;1.4 02-27-96 286 1.710.3;0.4 0.1 i 0.9 ;0.9 08-27-96 285 2.910.3;0.6
-0.210.6;0.6 03 05-96 281 2.210.3;0.5
-0.5 i 1.3; 1.3 09-03-96 287 3.4 0.4 ; 0.7
-0.011.2;1.2 03 12-96 290 2.410.3;0.5 0.1 i 1.3; 1.3 09-10-96 286 4.110.4;0.8 0.1 i 1.3; 1.3 03 19-96 287 2.510.3;0.5 0.112.4;2.4 09 17-96 2S5 1.7 0.3 ; 0.4
-0.4 1.4 ; 1.4 03-26-96 283 1.710.3;0.4
-0.211.6;1.6 09-24-96 284 2.710.3;0.6 0.4 1.0; 1.0 l
ist Qtr. Meants.d. 2.210.6 0.110.5 3rd Qtr. Mean s.d.
2.410.8 0.010.8 04-02-96 303 1.6 i 0.3; 0.4
-0.5 i 1.2; 1.2 10-01 96 297 2.6 0.3;0.6 0.2 0.9;0.9 04-09-96 272 1.610.3;0.4
-0.511.0;1.0 10-08-96 279 2.010.3;0.5 0.2 1.4 ; 1.4 04 16 284 1.110.3;0.3 0.4 i 1.2 ; 1.2 10-15-96 286 2.7 0.3; 0.6
-0.5 1.2: 1.2 04-23-96 275 1.4 i 0.3; 0.4 0.010.8;0.8 10-22 96 -287 2.710.3;0.6
-1.6 2.5; 2.5 04-30-96 285 1.1 i 0.3; 0.4
-0.6 i 1.2; 1.2 10-29-96 285 2.4 0.3; 0.5
-1.4 2.3 ; 2.3 05-07-96 294 2.0 0.3; 0.5 0.3 i 1.0;1.0 11-05-96 287 2.310.3;0.5
-0.1 1.5; 1.5 05-14 96 276 1.5 0.3: 0.4 0.2 1.1 ; 1.1 11 12-96 285 2.1 0.3; 0.5 0.6 1.6; 1.6 05-21 96 281 1.810.3;0.4
-0.1 1.0;1.0 11-19-96 2S5 2.910.3;0.6 0.8 1.0; 1.0
' 05-28-96 292 1.6 i 0.3; 0.4 1.4 1.3; 1.4 11-26-96 284 1.4 0.3; 0.4 0.5 1.5 ; 1.5 06-04-96 286 1.210.3;0.3 0.711.2;1.2 12-03-96 288 2.810.3;0.6 0.6 2.1 ; 2.1 06-11 96 290 0.8 0.2: 0.3 0.3 0.5;0.5 12-10-96 285 2.5 0.3; 0.6 1.7 2.2; 2.2 06-18-96 285 2.110.3;0.5 0.1 1.1 ; 1.1 12 17-96 2S6 2.3 0.3 ; 0.5
-1.0 1.6; 1.6 06-25-96 287 1.610.3;0.4
-0.111.0;1.0 12-24-96 286 2.4 0.3; 0.5
-0.0 1.0; 1.0 2nd Qtr. Meanis.d. 1.50.4 0110.5 12-31-96 285 3.1 0.4 ; 0.7 0.2 1.2 ; 1.2 4th Qtr. Mean s.d.
2.50.4
-0.1 0.9
- Pump malfunction; installed replacement pump.
1-5
LASALLE Table 2.
Airborne Particulates Collection:
Quarterly composites of weekly collections Required LLD Cs-134 = 0.01, Cs-137 = 0.01 pCi/m' Units:
10* pCi/m' Sample Description and Concentration L-01 Nearsite No.1 1996 Collection 1st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Period Lab Code LAP 2551 LAP-5033 LAP-7543 LAP-9832 Volume 3,704 3,722 3,731 3,164 Mn-54
-0.415.5;5.5
-5.115.0;5.1
-4.8 5.9; 6.0
-2.8 6.4; 6.4 Fe-59
-1.31 11.5;11.5 5.3.t 13.0; 13.0 0.7 16.8; 16.8 17.2 i 16.6; 16.9 Co-58 0.3 1 5.6; 5.6
-0215.6;5.6 4.7 5.7; 5.8
-7.6 5.6; 5.8 Co-60
-2.815.5;5.5 5.015.4;5.5
-4.2 5.8;58 5.0 6.9; 6.4 Zn-65
-13.8 1 11.3; 11.6 9.2 10.8; 10.9
-2.8 10.6; 10.6 10.8 10.4; 10.6 Zr-Nb-95 7.5 8.6; 8.7
-4.6 i 9.6; 9.6 0.9 i 9.2; 9.2 6.9 9.4 ; 9.5 Cs-134 4.215.0;5.1
-3.315.5;5.5 2.2 5.4; 5.5
-3.3i 5.9; 5.9 Cs-137 2.314.4;4.4 3.614.S;4.9 3.3 5.0; 5.0
-2.6 6.0; 6.0 lla-La 140 11.6 1 26.4; 26.5
-30.0 32.4; 32.8 14.3 i 14.3; 14.5
-34.3 43.2;43.6 L-03 Onsite No. 3 1996 Collection 1st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Period Lab Code LAP-2552 LAP-5034 LAP-7544 LAP-9833 Volume 3,696 3,684 3,5 M 3,140 Mn-54
- 5.1 4.9; 4.9 3.7 4.0; 4.1 0.115.9;5.9 3.8 5.0; 5.0 Fe-59 10.6 i 11.2; 11.4 0.7 10.6; 10.6 1.5 13.4; 13.4 7.1 14.2; 14.3 Co-58 2.5 4.9; 4.9 8.3 6.0; 6.1
-4.3 6.8; 6.8
-1.3 6.4;6.4 Co-60 1.015.7;5.7 5.1 ' 5.5; 5.6 2.9 4.5; 4.5 5.4 6.3; 6.4 Zn-65
-5.6 11.0; 11.0
-1.0 9.0; 9.0 18.2 10 6;11.1
-17.5 13.3; 13.7 Zr-Nb-95
-7.6111.2:11.3
-5.9 11.2; 11.2 7.5 10.9; 11.0
-8.9 10.0; 10.1 Cs-134 1.115.4;5.4
-3.2 4.7; 4.7 1.9 5.6; 5.6 8.7 7.0; 7.2 Cs-137
-3.0 5.2; 5.2
-0.8 5.3; 5.3 5.515.5;5.5
-2.6 6.0; 6.0 lla-La-140
-5.8 21.7; 21.7
-2.5 24.3; 24.3 15.7 23.6; 23.8
-60.1 1 43.2;44.5 9
2-1 l
LASALLE Table 2.
Airborne Particulates Collection:
Quarterly composites of weekly collections Required LLD: Cs 134 = 0.01, Cs-137 = 0.01 pCi/m' Units:
10 pCi/m' Sample Description and Concentration L-05 Onsite Station No. 5 1996 Collection 1st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Period Lab Code LAP 2553 LAP-5035,6 LAP-7545 LAP-9834 Volurne 3,675 3,668 3,709 3,160 Mn-54 1.614.3;4.3
-0.512.0;2.0
-0.315.6;5.6
-0.416.2;6.2 Fe-59 10.7 1 14.9; 15.0
-1.614.1;4.1
-0.71 14.2;14.2
-9.5 18.3; 18.4 Co 58 6.71 6.0;6.2 0.912.7;2.7
-9.31 5.6;5.8 1.4 6.8;6.8 Co-60 1.31 5.3;5.3
-0.5 1 2.2; 2.2 2.314.5;4.5
-3.0 7.0; 7.0 Zn 65
-1.6110.0;10.0 1.2 i 3.7; 3.7 2.819.4;9.5
-3.62 14.6;14.6 Zr Nb-95 2.917.9;8.0 1.0 4.6; 4.6 6.819.2;9.3 1.3 9.8; 9.8 O-Cs-134 1.1 1 5.2: 5.2 0.9 1 2.2; 2.2 2.215.5;5.5 2.3 4.9; 4.9 Cs-137 5.514.9;5.0 1.9 2.3;2.3 2.6 4.9;4.9 1.516.5;6.5 lla-La 140 15.9 1 24.8; 25.0
-6.1112.9;12.9
-8.5132.8;32.8
-10.8 33.0; 33.1 L-06 Nearsite No. 6 i
l 1996 Collection 1st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Period Lab Code LAP-2554 LAP-5037 LAP-7546 LAP-9835 Volume 3,723 3,695 3,546 3,159 Mn-54 0.6 4.7; 4.7
-1.9i 5.1; 5.1 6.815.5;5.6 5.2 4.9;4.9 Fe-59 17.1 12.3; 12.7
-10.8 15.1; 15.2
- 9. 8 18.6; 18.7 2.4 16.2; 16.2 Co-58
-1.7 5.9; 5.9
-1.l i 5.5; 5.5 3.4 5.7;5.8 2.8 6.3; 6.3 Co-60
-3.315.4;5.4 8.1 4.1; 4.3
-0.3 5.8; 5.8
-1.5 7.7; 7.7 Zn-65 10.2 1 11.0; 11.1
-15.4 i 13.6; 13.9
-3.0 13.5;13.5 7.2 12.1; 12.2 Zr-Nb-95
-0.417.9;7.9
-0.1 i 9.2; 9.2 2.9 6.9; 6.9 5.4 9.8; 9.5 Cs 134
-2.5 t 3.7; 3.7 0.1 5.6; 5.6
-0.3 6.3; 6.3
-2.11 7.1;7.1 Cs-137 0.9 i 4.4; 4.4 4.0 5.0; 5.1
-5.015.7;5.8
-0.516.0;6.0 Ba-La-140
-55.0 1 37.4; 38.7
-16.9 i 26.3; 26.5 35.1 29.5; 30.2
-18.9 37.0; 37.2 C(
2-2
LASALLE Table 2.
Airborne Particulate Collection:
Quarterly composites of weekly collections itequired LLD: Cs 134 = 0.01, Cs-137 = 0.01 pCi/m' Units:
10" pCi/m' Sample Description and Concentration L-10 (C) Sta:ater 1996 Collection 1st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Period Lab Code LAP-2555 LAP-5038 LAP-7547 LAl'-4836 Volume 3,765 3,710 3,703 3,148 Mn 54
-7.0 6.1; 6.2 1.315.3;5.3 7.9 5.1; 5.2 2.2 54;5.4 Fe-59
-20.9 15.0; 15.5 9.4 10.9; 11.0
-2.9115.3;15.3
-1.6 17.1; 17.1 Co-58
-3.51 5.2;5.2 0.415.4;5.4 0.5 t 5.3; 5.3
-0.8 6.5; 6.5 Co 60 0.515.5;5.5 5.8 4.1; 4.2
-6.51 6.5;6.6 6.9160;6.2 Zn-65 6.5 i 9.3; 9.4
-1.5 i 9.9; 9.9 7.4110.5;10.6 7.4 11.1; 11.2 Zr-Nb-95 5.4110.4;10.4 1.4110.1;10.1 0.119.1;9.1
-2.5 11.9; 11.9 Cs 134 0.115.4;5.4
-0.1 4.6; 4.6 1.3 5.4; 5,4 3.5 5.2; 5.3 Cs 137
-0.614.6;4.6 1.6 i 4.5; 4.5 3.0 4.7; 4.7 7.8 5.2; 5.3 Ba La-140
-8.7126.5;26.5 30.1 21.0; 21.7
-1.8129.9;29.9 57.2 30.9; 32.5 9
2-3
LASALLE Table 3.
Milk Collection:
Biweekly (May October)
Monthly (November April)
Required LLD: 1-131 = 0.5 pCi/L (May October),1131= 5 pCi/L (November - April),
Cs-134 = 15, Cr 137 = 18, Ba-La 140 = 15 pCi/L Units:
pCi/L Sample Description and Concentration L-16 (C) Lowerv Dairy Date Collected 01 02 96 02 09 96 03-05-96 04-02 96 Lab Code Lh11-47,8 LMI 703 LMI 1070 LMI 1852 1
1 131 0.06 1 0.15;0.15
-0.05 1 0.18;0.18
-0.04 1 0.20;0.20 0.06 0.24;0.24 Mn-54 1.512.4;2.4 0.512.1;2.1 0.112.6;2.6 0.I12.1;2.1 Fe 59 1.216.3;6.3 0.514.8;4.8 1.014.9;4.9 2.0 7.4;7.4 Co-58 0.712.5;2.5 1.112.2;2.2
-0.81 2.5;2.5 0.912.9;2.9 Co-60 2.4 i 3.3; 3.3 0.3 i 3.1; 3.1 0.5 1 3.1; 3.1
-0.3 i 2.6; 2.6 Zn-65 2.1 i 6.1; 6.1 0.215.4;5.4 3.4 6.1; 6.1
-0.7 4.9; 4.9 Zr-Nb-95
-1.412.8;2.8
-0,412.3;2.3 2.2 2.5; 2.5 2.3 4.2; 4.2 Cs-134 2.112.7;2.7 1.7 1 2.5; 2.5 0.21 2.8;2.8 0.5 2.5; 2.5 Cs 137 0.6i 2.7; 2.7 0.6 2.2;2.2
-0.4 2.6; 2.6 0.4 2.1; 2.1 Ba-La 140 0.7i 5.1; 5.1 1.8 i 3.1; 3.1 0.21 2.9;2.9
-7.9 12.5; 12.5 Date Collected 05-07-96 05-21 96 06-04-96 06-18 96 Lab Code LMl-2837 LMl-3218 LM13578 LMl-3849 l131
-0.07 i 0.20;0.20 0.15 1 0.19;0.19 0.24 1 0.25;0.25 0.00 1 0.21;0.21 Mn41
-0.713.1;3.1
-0.9 i 3.2; 3.2
-0.413.1;3.1
-0.6 2.0; 2.0 Fe-59 2.219.5;9.5 7.0 8.7; 8.7 5.6 8.2;8.2
-0.9 4.5; 4.5 Co-58
-2.0i 3.4; 3.4 2.213.7;3.7
-2.114.0;4.0 0.1 ! 2.1; 2.1 Co-60 0.114.6;4.6 0.4 4.7; 4.7
-0.4 i 4.8; 4.8 1.3 2.5; 2.5 Zn-65 0.3i 7.2; 7.2 0.119.4;9.4 3.4 9.1; 9.1 1.214.9;4.9 Zr-Nb-95 0.313.8;3.8
-0.3 3,9; 3.9
-0.1 3.3; 3.3 0.8 2.3; 2.3 Cs-134 0.314.0;4.0 1.814.1;4.1
-0.3 3.6; 3.6
-0.1 2.2; 2.2 Cs-137 2.513.8;3.8 2.8 3.7; 3.7
-0.3 4.1; 4.1 0.5 2.4; 2.4 Ba La 140 2.713.6;3.6
-3.313.7;3.8
-2.2 5.4; 5.4 0.811.9;1.9 O
V 31 l
______u
LASALLE Table 3.
hiilk Collection:
Biweekly (hfay Cxtober) hionthly (November April)
Required LLD: 1-131 = 0.5 pCi/L (hf ay October),1131= 5 pCi/L (November - April),
Cs-134 = 15, Cs-137 = 18, Ba-La 140 = 15 pCi/L Units:
pCi/L Sample Description and Concentration L-16 (C) Lowery Dairy Date Collected 07-02-96 07-16-96 07-30-96 08-13-96 Lab Code Lh114399 Lh11-4746 Lhil-5050 Lh11-5494 1131
-0.18 1 0.38;0.38 0.21 1 0.33;0.33 0.05 0.30;0.30 0.00 0.25;0.25 hin-54
-0.3 2.6; 2.6
-0.113.1;3.1
-1.3 2.1; 2.1 0.5 2.9; 2.9 Fe-59 4.7i 5.4; 5.4 1.319.1;9.1
-3.115.7;5.7 1.2 t 7.6; 7.6 Co-58 0.5 1 2.4; 2.4
-2.513.1;3.1
-1.512.3;2.3 2.0 3.0; 3.0 Co-60 5.213.3;3.4 3.114.1;4.1 0.8 3.3; 3.3
-2.5 4.5; 4.5 Zn-65
-5.816.8;6.8
-1.417.9;7.9 0.216.1;6.1
-1.8 7.7; 7.7 Zr Nb-95
-0.312.6;2.6
-2.4 3.4; 3.4 0.7 2.7; 2.7
-0.1 3.2; 3.2 Cs 134
-1.013.0;3.0 0.313.4;3.4 0.71 2.7;2.7
-1.113.4;3.4 Cs 137 0.9 t 2.9; 2.9 2.4 3.6; 3.6 0.71 2.4;2.4
-0.5 3.1; 3.1 Ba-La-140
-0.814.2;4.2
-3.313.5;3.5 4.2-i 4.1; 4.1 1.3 4.6; 4.6 Date Collected 08-27-96 09-10-96 09-24 96 10-08 96 Lab Code th115817,8 Lh116191 Lh11-6497 Lh11-6486 1131 0.04 1 0.05;0.05 0.09 1 0.24;0.24 0.19 1 0.32;0.32
-0.23 1 0.26;0.26 hin-54 0.6 2.4; 2.4 2.8 2.7; 2.7
-0.4 3.2; 3.2
-0.7! 2.7; 2.7 Fe 59
-3.4 i 5.3; 5.3 0.4 5.9; 5.9 1.8 9.8;9.8
-1.71 5.3;5.3 Co-58 0.212.4;2.4 0.413.0;3.0 0.4 3.2; 3.2 0.2 2.1; 2.1 Co-60
-0.3 3.3; 3.3
-0.213.5;3.5 4.5 4.8; 4.8
-0.3 2.8; 2.8 Zn-65
-2.7i 6.0; 6.0
-4.2 7.0; 7.0
-6.1 9.0; 9.0 1.0 6.0; 6.0 Zr-Nb-95
-1.3 2.2; 2.2 1.213.1;3.1
-1.7 3.6; 3.6
-1.2 2.9; 2.9 Cs-134 0.7 2.8; 2.9
-1.512.5;2.5
-0.5 3.2;3.2 0.5: 2.9; 2.9 Cs-137 0.412.8;2.8
-1.612.9;2.9 1.8 3.3; 3.3 0.7 2.6; 2.6 Ba-La-140
-0.612.6;2.6 1.115.5;5.5 2.2 3.6;36
-0.51 3.6;3.6 9
3-2
LASALLE Table 3.
Milk Collection:
Biwe kly (May - October)
Monthly (November - April)
Required LLD: 1131 = 0.5 pCi/L (May October),1131= 5 pCi/L (November - April),
Cs-134 = 15, Cs 137 = 18, Ba La 140 = 15 pCi/L Units:
pCi/L Sample Description and Concentration L 16 (C) Lowery Dairy Date Collected 10-22 96 11 05-96 12-03-96 Lab Code LMl-7509 LMI 8047 LMI-8640 1131 0.26 1 0.29;0.30 0.24 1 0.21;0.21 0.15 1 0.17;0.18 Mn-54 0.8 i 4.4; 4.4 0.912.5;2.5 0.212.2;2.2 Fe 59 0.8111.3;11.3 0.3 5.1; 5.1 1.9i 5.1; 5.1 Co-58 1.214.4;4.4 0.912.3;2.3
-0.212.2;2.2 l
Co-60 1.51 6.6;6.6 0.412.9;2.9 0.6 1 2.5; 2.5 Zn-65 8.4111.2;11.3 2.315.8;5.8 0.3 5.1;5.1 Zr Nb-95 3.215.4;5.4 2.112.7;2.7 1.012.7;2.7 tqy Cs 134 3.5 4.9; 4.9 1.412.6;2,6
-1.812.6;2.6 Cs 137 3.014.8;4.8 1.0 1 2.6; 2.6 1.51 2.4;2.4 Da La 140
-11.5 i 9.2; 9.3
-1.113.1;3.1 1.0 3.3; 3.3 3-3
LASALLE Table 3, Milk Collection:
11iweekly (May - October)
Monthly (November - April) llequired LLD; l 131 = 0.5 pCi/L (May - October),1131= 5 pCi/L (November - Apnl),
Cs-134 = 15, Cs-137 = 18, Ba-La-140 = 15 pCi/L Units:
pCi/L Sample Description and Concentration L-41(C) Butten.Earm Date Collected 01 02-96 02-06-96 03 05-46 04-02-96 Lab Code NS' NS' NS' NS' 1-131 M n-54 Fe-59 Co-58 Co-60 Zn 65 Zr-Nb-95 Cs-134 Cs-137 Ba La-140 Date Collected 05-07-96 05-21-96 06-04-96 06-18 96 Lab Code NS' NS' NS' NS' I-131 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140
' NS = No sample; cow is in calf.
9 3-4
LASALLE G
Table 3.
Milk b
Collection:
Biweekly (May October)
Monthly (November April)
Required LLD: 1131 = 0.5 pCi/L (May October),1131= 5 pCi/L (November April),
Cs 134 = 15, Cs-137 = 18, Ba La-140 = 15 pCi/L Units:
pCi/L Sample Description and Concentration L-41 (C) Burton Farm Date Collected 07 02-96 07 16-96 07-30 96 08 13-96 Lab Code NS' NS' NS' NS6 1131 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Q
Zr-Nb 95 Cs 134 Cs 137 Ba La 140 O
' NS = No sample; cow is in calf.
- NS = No sample; farmer removed himself from program.
3-5
LASALLE l
Table 4.
Fish, Edible Portions Collection:
Semiannually Required LLD: Mn-54 = 0.13, Fe-59 = 0.26, Co-58 = 0.13, Co-60 = 0.13, Zn45 = 0.26, Cs-134 =
0.1, Cs 137 = 0.1 pCi/g wet weight Units:
10 pCi/g wet weight t
l Sample Description and Concentration t
L-35 Marseilles Pool of Illinois River Date Collected 05-02-96 05-02-96 05 02-96 05-02-96 Lab Code LF-2628 LF-2629 LF-2630 LF-2631 Type Quillback River Carpsucker Channel Catfish Carp Mn-54
-0.210.5;0.5 0.510.7;0.7 0.411.1;1.1 0.1 0.9; 0.9 Fe-59 0.111.0;1.0 0.311.8;1.8
-1.912.8;2.8 0.112.0;2.0 Co-58 0.110.5;0.5
-0.310.9;0.9
-0.4 1.1 ; 1.1
-0.110.9;0.9 Co-60
-0.010.6;0.6
-0.711.1;1.1 1.5 i 1.5; 1.5 0.411.4;1.4 Zn-65
-0.6 i 1.2; 1.2
-0.7i 2.0; 2.0 2.012.5;2.5
-1.112.2;2.2 Zr-Nh-95
-0.010.6;0.6
-0.210.8;0.8 0.3 1 1.2; 1.2
-0.4 1.0; 1.0 Cs-134
-0.210.5;0.5 0.4 i 0.9; 0.9 0.7 1 1.1; 1.1 0.910.8;0.8 Cs-137 0.110.6;0.6 0.110.9;0.9 0.811.2;1.2 0.7 1.0; 1.0 Ba-La 140
-0.310.6;0.6
-0.3 1 1.3; 1.3
-1.0 1.2; 1.2
-0.4 1.3; 1.3 Date Collected 05-02-96 10-24-96 10-24-96 10-24-96 Lab Code LF-2632 LF-7583 LF-7584,5 LF-7586 Type White Bass Channel Catfish Dmm Carp Mn 54 0.111.9;1.9
-0.410.7;0.7 0.1 0.5;0.5 0.3 0.6; 0.6 Fe-59 2.3i 4.0; 4.0 0.2 1 2.2: 2.2 0.5 1.1; 1.1 0.2 1.8; 1.8 Co-58 0.5 t 1.7; 1.7
-0.510.9;0.9 0.2 0.5; 0.5 0.4 0.6; 0.6 Co-60 0.712.1;2.1 0.2 1.0; 1.0 0.310.6;0.6 0.2 0.8; 0.8 Zn-65
-4.4 i 3.8; 3.9 0.5i 2.1; 2.1 0.4 1 1.2; 1.2
-0.511.8;1.8 Zr-Nb-95
-0.5i 3.2; 3.2
-0.2 1.2; 1.2
-0.1 0.5; 0.5 0.2 0.8; 0.8 Cs-134
-0.4 i 1.9; 1.9
-0.5 i 1.0; 1.0 0.3 0.5;0.5 0.1 i 0.7; 0.7 Cs-137 1.111.8;1.8 0.310.8;0.8 0.0 0.5; 0.5 0.11 0.6;0.6 Ba-La-140
-2.112.7;2.8 0.8 i 3.6; 3.6 0.3 i 1.0; 1.0 0.4 1 1.3; 1.3 O
l 1
4-1
LASALLE 1
Table 4.
Fish, Edible Portions Collection:
Semlannually Required LLD. Mn-54 = 0.13, Fe 59 = 0.26, Co 58 = 0.13, Co40 = 0.13, Zn-65 = 0.26, Cs 134 =
0.1, Cs 137 = 0.1 pCl/g wet weight Units:
10 pCi/g wet weight i
Sample Dvscription and Concentration L 35 Mars.ellies Pool of Illinois River Date Collected 10-24 96 10-24 96 Lab Code LF 7587 LF 7588 Type White Bass Largemouth Bass Mn 54 0.010.6;0.6 0.410.7;0.7 Fe 59 1.7i 1.8; 1.8 2.1
- 2.5; 2.5 Co 58 1.110.7;0.8 0.110.7;0.7 Co-60
-0.1 i 0.8; 0.8
-0.4 i 1.2; 1.2 Zn-65 0.211.4;1.4 1.712.4;2.4 Zr Nb 95
-0.210.9;0.9 0.6 i 0.9; 0.9 Cs 134 0.5
- 0.7; 0.7 0.2 i 0.3; 0.8 Cs 137 0.110.6;0.6 0.2
- 0,9; 0.9 Ba La 140
-0.5 i 1.0; 1.0 0.7 f 2.0; 2.0 O
' 42 m
LASALLE Table 4.
Fish, Edible Fortions Collection:
Semiannually Required LLD: Mn 54 = 0.13, Fe-59 0.26, Co 58 = 0.13, Co-60 = 0.13, Zn 65 = 0.26, Cs 134 =
0.1, Cs 137 = 0.1 pCi/g wet weight 4
Units:
10 pCl/g wet weight Sample Description and Concentration L 36 (C) lilinois Rh cr. Upstream l
Date Collected 05-02 96 05 02 96 05 02 96 05 02 96 Lab Code LF 2633,4 LF-2635 LF 2636 LF 2637 Type Carp Channel Catfish Freshwater i un Smallmouth Buffalo Mn 54 0.1 i 0.4; 0.4 0.011.0;1.0
-0.210.8;0.8 0.1 0.5; 0.5 Fe 59 0.31 1.0;1.0 0.5 1 2.2; 2.2 0.2 1.9;1.9 0.3 1 1.1; 1.1 Co-58 0.110.5;0.5 0.310.9;0.9 0.4 0.8; 0.8 0.310.5;0.5 Co-60 0.610.8;0.8 0.7 1 1.3; 1.3 0.211.1;1.1 0.510.6;0.6 Zn 65
-0.0 i 1.3; 1.3 0.712.4;2.4 0.1 1.8; 1.8 0.911.1;1.1 j
g Zr Nb 95
-0.51 0.5;0.5 0.2 i 1.0; 1.0 0.310.6;0.6 0.5 1 0.5; 0.5 Cs 134 0.110.5;0.5 1.2 1 1.0; 1.0
-0.210.8;0.8 0.1 06;0.6 Cs 137 0.5 i 0.5; 0.5 1.2 i 1.1; 1.1
-0.210.8;0.8 0.310.5;0.5 Da La 140 0.210.6;0.6 0.5 i 1.3; 1.3
-0.510.7;0.7
-0.010.5;0.5 Date Collected 05 02 96 10 24-96 10 24 96 10 24 96 Lab Code LF-2638 LF 7579 LF 7580 LT 7581 Type Smallmouth Dass Carp Smallmouth Buffalo River Carpsucker Mn-54 0.2 1 1.2; 1.2 0.110.9;0.9 0.410.7;0.7 0.1 0.7;0.7 Fe-59 1.31 2.5;2.5 0.512.8;2.8 0.812.0;2.0 0.1 2.6;2.6 Co 58 0.81 1.4;1.4 0.4 i 1.1; 1.1 0.210.7;0.7 0.5 0.9; 0.9 Co-60 0.511.5;1.5 0.0 t 1.1; 1.1 0.411.0;1.0 0.4 0.9; 0.9 Zn-65
-1.112.5;2.5 1.011.9;1.9 1.1 1 1.7; 1,7
-1.5 1.9; 1.9 Zr Nb-95 0.411.2;1.2 0.4 1 1.5; 1.5 0.5 0.9;0.9 0.6 1 1.2 1.2 C5134 0.7 1 1.5; 1.5 0.211.0;1.0 0.510.8;0.8 0.4 0.7; 0.7 Cs 137 0.3 1 1.3; 1.3
-0.310.8;0.8
-0.110.9;0.9 0.0 0.7; 0.7 0a La 140
-0.811.7;1.7 0.9 i 4.2; 4.2 1.6 1 1.0; 1.1 1.413.6;36 9
4 4-3
LASALLE l
Table 4.
Fish, Edible Portions Collection:
Semlannually llequired Lt.D; hin 54 = 0.13, Fe-59 = 0 26, Co-58 = 0.13, Co 60 = 0.13,2n 63 = 026, C3134 =
0.1, Cs 117 = 0.1 pCi/g wet weight Units:
10 pCi/g wet weight Sample Description and Concentration L-36 (C) lilinois Rh cr. U.P& cam Date Collected 10 24 96 Lab Cale LF 7582 Type Channel Catfish hin.54 0.1 1 0.7; 0.7 Fe 59 1.5i 2.5; 2.5 Co 58 0.711.0;1.0 Co-60 0.2 1 1.1; 1.1 Zn-65 0.612.3;2.3 Er Nb 95 0.111.5;1.5 C5134 0.61 0.9;0.9 Cs-137 0,110.7;0.7 Da La 140 0.3 1 4.5; 4.5
[
44
LASALLE Table 5.
Ilottom Sediments Collection:
Semiannually itequired LLD; Cs 134 = 0.15, Cs 137 = 0.18 pCi/g dry weight Units:
10 ' pCi/g dry weight Sample Description and Concentration 1.40_ lllinios liinulMantille Date Collected 05 21 96 10-15 06 1.ab Code LBS-3221 LDS 7334 hin+1 0.311.4;1.4 1.0 1.0; 1.0 Fe 59 1.114.0;4.0 0.9 2.5; 2.5 Co-58 0.711.5;1.5 0.1 1.1 ; 1.1 Co 60 0.3 2.3; 2.3 0.211.3;1.3 Zn-65
-8014.5;4.6
-0.212.6;2.6 Zr Nb 45 2.51 2.0;2.0
-4.01 1.5;1.6 C$ 134 2.31 1.7;1.8 0.2 i 1.0; 1.0 Cs-137 1.5 1.7; 1.7 0.911.0;1.0 lla La-140 0.1 3.0; 3.0 1.0180;8.0 9
5-1
LASALLE Table 6.
Vegetation Collection:
Triannually l
Required LLD; l 131 = 0 06, C$ 134 = 0.06, C5137 = 0.08 pCl/g wet weight Units:
10 pCi/g wet weight Sample Description and Concentration le.4016mb S.L l
Date l
Collected 08 13 96 08 13 96 08 13 96 0813 oo l
12b Code LVE 5500 LVE 5501 LVE-5502 LYE 5503 Type Kohlrabi Greens Deet Greens Kohlrabi
- Deet, l.131 0.65 i 1.35;1.35 0.65 i 1.81;1.81 0.201088;o88 1.2616 u7 ; 6.97 Mn 54 1.211.0;1.1 0.01 2.0;2.0 0.31 0.9;0.9 0.2 5.0;5.0 Fe-59 0.51 2.3;2.3 0.8 i 4.2; 4.2 0.51 1.7;1.7 6.8110.4;10.4 Co-58 0.51 1.0;1.0 1.312.0;2.0 0.110.6;o6 1.0 5.2i5.2 Co-60 0.21 1.4;1.4 0.812.4;2.4 0.111.1;1.1 0.31 5.9;5.9 Zn-65 0.21 2.8;2.8 0.214.6;4.6 1.811.5;1.6 11.0 1 12.1; 12.2 Zr-Nb 95 0.411.0;1.0 1.412.0;2.0 0.310.8;0.8 3,6 5.1;5.2 Cs134 0.5 i 1.1; 1.1 0.112.2;2.2 0.110.9;0.9 5.5 6.0; 6.0 C5137 0.1 1 1.1; 1.1 0.812.1;2.1 0.510.9;0.9 2.4 6.0; 6.0 lla.La 140 0.211.4;1.4 5.91 3.1;3.2 1.1 0.7;0.7 1.9 7.9;7.9 6-1
LASALLE Table 6.
Vegetation Collection:
Triannually itequired LLD. 1 131 = 0.06, Co 131 = 0.06, Cs-137 = 0 08 pCi/g wet weight 4
Units:
10 pCi/g wet weight l
Sample Description and Concentration l
1..LWtrel. Eugoe Ck mtnth Date l
Collected 10-14 96 10-14 96 10 14 96 1.ah Cnie LVE 7335 LVE 7336 LVE 7337 Type Cabbage l'epper Leaves Peppers 1131 0.421086;0.86 1.891216;2.77 0.97 1 2.15;2.15 Mn 54 0.110.8;O8 0.912.3;2.3 1.8 1.8; 1.8 re 59 1.912.2;2.2 1.714.4;4.4 2.31 3.2;3.2 Co-58 0.410.8;0.8 0.4120;2.0 1.31 1.8;1.8 Co-60 0.3 1 1.2; 1.2 2.212.7;2.7 0.0 2.1 ; 2.1 Zn 65
-0.712.1;2.1 0.7154;5.6 0.913.7; 3J Zr Nb-95 0.710.8;0.8
-0.612.6;2.6
-0.4 3.0; 3.0 Cs-134 0.510.9;0.9 1.8 1 2.8; 2.8
-0.3120;2.0 Cs 137 1.1 i 1.0; 1.0 1.7 2.6; 2.6 0.211.9;1.9 Ba La 140 0.211.0;1.0 0.512.7;2.7 1.0124;2.4
~.
O 6-2
l LASALLE Table 6.
Vegetation Collection:
Triannually llequired LLD. 1131 = OM Cs 134 = 0.06, CS 137 = 0.08 pCi/g wet weight l
l Units:
10 pC1/g wet weight l
Sample Description and Concentration 1 guad 1 (Location notyrildentified)
Date Collected 01 02 96 Lab Code NS Type 1131 Mn54 re 59 Co 58 Co-(4 Zn-65 Zr Nb-95 Cs 134 Cs 137 l
Ila La 140 l
- NS = No sample; sample collector unable to identify new vegetation location in this quadrant.
W
LASAll E Tatile 6.
Vegetation Collection:
Triannually 1(equired LLD: 1 131 - 0 06, Cs 134 = 0 06, Cs 137 = 0 08 pCi/g wet weight Units:
10 pCi/g wet weight Sample Description and Concentration kauadl_Ileralienneutudentied)
Date Collected 01 02 96 1.ab Code NS Type l
l131 Mn-54 fe 59 Co-58 Co-60 Zn-65 Zr Nb 95 Co.134 Cs-137 lla La 140
- NS = No sample; sample collector unable to identify new vegetation location in this quadrant.
O 64 l
LASALLE Table 6.
Vegetation Collection:
Triannually Required LLD: 1131 = 0.06, C61M = 0 06, C3-137 = 0 08 pCi/g wet weight Units:
10 pCl!g wet weight Sample Description and Concentration L. Quad 3 Ettema's Farrn Date Collected 07 23 96 07 23-96 08-07 96 08 07 96 Lab Code LVE 4901 LVE 4902 LVE 5366 1.YE 5367 Type Cabbage Corn Deets Deet Greens 1131 0.19 1 0.67;0.67 0,12 1 1.31;1.31 0.47 1 0.98;0.99 0.75 1 1.53;1.53 Mn 54 0.4 1 0.6; 0.6 0.710.8;0.8 0.210.6;0.6 0.4 0.8;0.8 Fe 59 0.211.4;1.4 0.312.0;2.0
-0.711.3;1.3
-0.71 2.4;2.4 Co 58
-0.110.6;0.6 0.6i 0.8; 0.8 0.01 0.6;0.6 0.51 0.9;0.9 Co 60 0.210.9;0.9 0.3 1 1.1; 1.1 0.310.7;0.7 0.31 1.3;1.3 Zn-65 2.011.4;1.5-0.312.1;2.1 0.711.3;1.3 0.2 2.4; 2.4 Zr Nb 95
-0.210.6;0.6 0.5 i 1.5; 1.5 0.010.5;0.5 0.111.0;1.0 C5134 0.21 0.7;0.7 0.411.0;1.0 0.610.6;0.6 0.31 1.1;1.1 Cs.137 0.110.6;06 0.411.0;1.0
-0.21 0.6;0.6 1.3 0.9; 0.9 Da La 140 0.31 0.4;0.4 0.210.8;0.8
-0.110.6;0.6 0.311.0;1.0 Date Collected 08-07 96 08-13 96 08 13 96 08-13 96 Lab Code LVE 5368 LVE 5497 LVE 5498 LVE 5499 Type Cabbage Red Cabbage Kohlrabi Greens Kohlrabi 1131 0.16 i 1.20;1.20 0.18 i 0.80;0.80 0.47 1 1.19;1.19 0.40 t 1.00; 1.00 Mn-54
-0.210.6;0.6 0.110.7;0.7 0.1 1 1.0; 1.0 0.6 0.8; 0.8 Fe-59 0.4 i 1.5; 1.5 0.2 1.4 ; 1.4 0.212.3;2.3 0.1 1 1.5; 1.5 Co-58 0.210.7;0.7
-0.710.7;0.7 0.5 1.1; 1.1 0.0 0.9;0.9 Co-60 0.31 0.9;0.9 0.5 1 0.8; 0.8 0.7 1.3; 1.3 0.51 0.9;0.9 Zn-65 1.412.0;2.0 0.411.5;1.5 0.6 1 2.5; 2.5 1.2 1.8; 1.8 Zr Nb-95 0.310.8;0.8 0.210.8;0.8 0.3 1.1;1.1 0.6 0.9;0.9 CS 134 0.611.0;1.0 0.210.8;0.8 0.5 1 1.2; 1.2 0.6 08;0.8 C3-137
-0.910.8;0.8 0.310.8;0.8
-0.811.3;1.3 0.8 0.9; 0.9 Da La 140 0.511.1;1.1 0.310.8;0.8
-0.21 1.3;1.3
-0.0 0.8;0.8 65
LASALLE Table 6.
Vegetation Collection:
Triannually itequired LLD. 1131 = 0 06. Cs-134 = 0 06, Cs-137 = 0 08 pCi/g u et weight 2
Units:
10 pCi/g wet weight Sample Description and Concentration L quad 4 (Location no13 et identified)
Date Collected 01 02 96 Lab Code NS Type 1131 Mn 54 l'e 54 Co-58 Co-60 Zn 65 Zr-Nb 95 Cs-134 Cs-137 Ila La 140
- NS = No sample; sample collector unable to identify new vegetation hication in this quadrant.
6-6
LASALLE Table 7.
Surface Water Collection:
Monthly composites of weekly collections Required LLD: Gross Beta = 4, Mn 54 = 15, Fe-59 = 30, co 58 = 15, Co-60 = 15, Zn-65 = 30, Zr Nb 95 = 15 Cs 134 = 15, Cs 137 = 18, Ba La 140 = 15 pCi/L Units:
pCl/L Sample Description and Concentration L 21 (C) Illinois River at Seneca 1996 Collection January February March l
Period Lab Code LSW 596*
LSW 916' LSW 1849 CrossBeta 5.811.0;1.4 6.211.4;1.7 4.811.4;1.6 Mn-54 1.9 i 2.7; 2.7 1.112.6;2.6 1.0i 1.7; 1.7 Fe 59 2.3i 5.6; 5.6 3.0i 5.9; 5.9
-0.413.7;3.7 Co 58 3.1 i 2.8; 2.8 1.512.7;2.7 0.5 i 1.6; 1.6 Co-60 0.8i 2.5; 2.5 0.5 i 2.3; 2.3 0.2 1 1.7; 1.7 e
Zn 1.21 5.3;5.3 1.915.6;5.6 1.8 3.2; 3.2 Zr Nb 95 2.213.4;3.4
-0.8i 2.6; 2.6 0.3 1 3.0; 3.0 Cs 134 1.2 i 3.1; 3.1
-1.6i 3.0; 3.0 1.011.9;1.9 Cs 137 0.3 i 2.9; 2.9 0.3 i 2.7; 2.7 0.4 1 1.9; 1.9 Ba La 140 9.5 6.3; 6.4 0.414.8;4.8 1.7 3.9; J.9 1996 Collection April May June Period Lab Code LSW-2801 LSW 3676 LSW 4477 Cross Beta 4.311.7;1.8 4.0 i 1.1 ; 1.3 4.9 i 1.2 ; 1.4 Mn 54 0.412.4;2.4 1.0 1 1.8; 1.8
-0.41 1.8;1.8 Fe 59 3.113.5;3.5 2.4 i 4.2; 4.3 1.713.9;3.9 Co-58 0.5i 2.0; 2.0 0.4 i 2.0; 2.0 0.8 1 2.1; 2.1 Co-60 0.5i 1.9; 1.9 1.2 i 1.7; 1.7 0.5 1.7; 1.7 Zn-65 0.514.8;4.8 0.5 t 3.2; 3.2
-1.9 4.1;4.1 Zr Nb 95 0.8 i 1.9; 1.9 0.212.2;2.2 0.1 1 2.5; 2.5 Cs 134
-1.412.3;2.3 0.111.8;1.8 0.612.0;2.0 Cs 137 1.61 2.5;2.5 0.212.1;2.1 0.2 1.8; 1.8 Ba La 140 2.413.1;31 1.7i 3.9; 3.9 2.0i 5.7; 5.7 O
' Results reflect four weekly collections during the month.
- Results reflect three weekly collections during the month.
71
LASALLE l
Table 7.
Surface Water Collection:
Monthly composites of weekly collections h
Required LLD. Gross Beta = 4, Mn 54 = 15 Fe-59 = 30, Co 58 = 15, Co-60 = 15, Zn 65 = 30, Zr Nb 95 = 15, Cs 134 = 15, Cs-137 = 18, Ba La 140 = 15 pCi/L Units:
pCi/L Sample Des.cription and Concentration L-21 (C) Illinois River at Seneca 1996 Collection July August September Period Lab Code LSW 5284*
LSW 6116 LSW 6995 Gross Deta 4.4 i 1.0:1.2 5.111.6;1.8 5.4 i 1.2 ; 1.5 Mn-54 1.012.8;2.8 1,712.7;2.7 0.912.1;2.1 Fe 59 1.217.4;7.4 2.912.9;2.9 1.1 i 4.9; 4.9 Co-58 2.812.5;2.6 1.013.5;3.5 0.8i 2.3; 2.3 Co-60 1.013.2;3.2 1.0i 3.0; 3.0 0.211.9;1.9 Zn-65 5.814.1;4.1 4.416.9;6.9 3.514.8;4.8 Zr Nb 95 0.6 i 3.4; 3.4
-1.113.1;3.1 0.5 1 3.4; 3.4 Cs 134 0.813.1;3.1 0.113.0;3.0 1.2 1 2.5; 2.5 Cs-137 0.113.7;3.7 1.4 i 3.3; 3.3
-0.9i 2.5; 2.5 Ba La 140 1.51 2.1;2.2 2.6i 7.7; 7.7 1.316.0;6.0 1996 Collection October November December Period Lab Code LSW 8131 LSW 8679 LSW 9719 Gross Beta 5.9 i 1.5 ; 1.7 7.011.4;1.7 4.7 i 1.7;1.8 Mn 54 0.3i 1.8; 1.8 0.3 t 2.3; 2.3 0.812.2;2.2 Fe 59 0.813.0;3.0 5.017.1;7.1 1.015.0;5.0 Co-58 1.412.0;2.0 1.3i 3.3; 3.3 1.812.4;2.4 Co-60 1.111.8;1.8
-1.013.3;3.3 1,0i 2.0; 2.0 Zn-65 0.713.3;3.3 0.2 1 5.2; 5.2 0.714.4;4.4
)
Zr Nb-95 2.712.8;2.8 1.513.1;3.1 0.612.9;2.9 C3-134 0.812.1;2.1
-1.913.0;3.1 0.812.0;2.0 Cs-137 0.512.0;2.0
-0.113,6;3.6 0.5 1 2.3; 2.3 Da La 140 4.113.7;3.7 3.6i 8.8; 8.8 11.217.2;7.3
' Results reDect four weekly collections during the month.
- Results reDect three weekly collections during the month.
7 -2
LASALLE Table 7.
Surface Water Collection:
hionthly composites of weekly collections Required LLD: Cross Deta = 4, hin 54 = 15, Fe-59 = 30 Co 58 = 15. Co-60 = 15, Zn-65 = 30.
Zr Nb-95 = 15, Cr.134 = 15, Cs 137 = 18, Ba La 140 = 15 pCi/L Urits:
pCl/L Sample Description and Concentration L-40 illinois River Downstream 1996 l
Collection January February h1 arch Period Lab Code LSW 597' LSW 917' LSW 1850 Cross !! eta 6.5 i 1.1 ; 1.5 7.311.3;1.7 6.511.4;1.7 hin 54 0.8 1.7; 1.7 0.512.9;2.9 0.812.4;2.4 Fe 59
-0.213.5;3.5 4.0i 6.0; 6.1 2.3 i 6.5; 6.5 Co 58 0.812.0;2.0 1.4 1 2.6; 2.6 0.913.0;3.0 Co-60 0.211.9;1.9 1.7 i 3.1; 3.1 0.513.2;3.2 Zn-65 0.714.5;4.5 2.415.6;5.6 0.2 1 5.5; 5.5 Zr Nb 95 0.112.2;2.2 0.213.2;3.2 1.7 4.9;4.9 Cs 134 0.7i 2.2; 2.2 0.113.1;3.1 0.2 i 2.7; 2.7 Cs 137 0.4 i 2.0; 2.0 1.612.9;2.9 1.8 i 2.9; 2.9 Ba La 140 0.413.7;3.7 2.115.3;5.3 2.9 1 5.3; 5.3 1996 Collection April hiay June Period Lab Code LSW 2802 LSW 3677,8 LSW 4478 Gross Beta 5.9 i 1.8 ; 2.0 5.710.9;1.1 4.7 1 0.9;1.2 hin 54 0.9i 2.6; 2.6 0.411.6;1.6 1.01 2.3;2.3 Fe 59 4.7i 7.2; 7.2 1.7i 4.2; 4.2 2.215.7;5.7 Co-58 1.1 i 3.0; 3.0 0.211.7;1.7 1.8 2.6;2.6 Co-60 2.4 i 3.6; 3.6 0.311.5;1.5 5.0 3.0; 3.1 Zn-65 2.215.3;5.3 2.213.5;3.6 3.814.9;4.9 Zr Nb-95 0.9 1 3.3; 3.3 2.412.1;2.1 0.3 3.5;3.5 Cs-134 2.71 3.1;3.1 0.4 i 2.2; 2.2 0.1 i 2.2: 2.2 Cs-137
-0.8 i 3.0; 3.0 0.21 2.0;2.0
-0.412,7;2.7 Ba La 140 4.213.5;3.5
-2.7i 3.8; 3.8 4.2 8.8;8.8
- Results reflect four weekly collections during the month.
- Results reflect three weekly collections during the month.
7-3
LASALLE Table 7.
Surface Water Collection:
hionthly composites of weekly collections itequired LLD; Cross Beta = 4, hin-54 = 15, re-59 = 30, Co-58 = 15, Co 60 = 15, Zn-65 = 30, Zr Nb 95 = 15, C8134 = 15, Cs 137 - 18, Da-La 140 = 15 pCi/L Units:
pCi/L Sample Description and Concentration L-40 tilinois River Downstream 1996 Collection July August September Period Lab Code LSW 5285' LSW 6117 LSW-6946 Gross Beta 5.310.9;1.2 5.611.7;1.9 62 1.3 ; 1.6 hin-54 0.811.9;1.9 0.112.0;2.0
-0.212.0,2.0 Fe 59 1.013.9;3.9
-0.414.8;4.8 05 52;52 Co-58 0.1 1.8; 1.8 0.8 2.0; 2.0 1.3 1 2.5; 2.5 Co 60 1.211.9;1.9 0.811.9;1.9 0.8i 2.3; 2.3 Zn-65 1.413.9;3.9 2.614.0;4.0 2.8 i 4.8; 4.8 Zr-Nb 95 1.012.0;2.0 0.21 2.7;2.7 1.9 3.6; 3.6 Cs 134 1.01 2.1;2.1 0.71 2.3;2.3 1.11 2.8;2.8 Cs 137 1.01 2.1;2.1 0.112.1;2.1 2.0 2.4; 2.4 Da La 140 1.31 3.8;3.8 0.714.8;4.8
-4.4 i 7.2; 7.3 1996 Collection October November December Period Lab Code LSW 8132 LSW 8680
'9720 Gross Deta 4.711.3;1.5 6.6 1.3 ; 1.6 5.1 1.6 ; 1.8 hin M 0.21 2.0;2.0 0.1 2.3;2.3 0.51 3.1;3.1 Fe-59 1.714.7;4.7
-2.014.1;4.1
-3019.3;9.3 Co-58 0.3 2.2; 2.2 0.81 2.6;2.6 0.3 3.2; 3.2 Co-60
-0.31 2.6;2.6 0.412.1;2.1 1.3 3.2:3.2 Zn 65 0.4 3.8; 3.8
-1.6 4.5; 4.5 2.3 5.3; 5.4 Zr-Nb-95 0.5 2.9; 2.9
-3.414.3;4.3
-30i3.8;3.8 Cs 134 0.3 2.1;2.1 0.2 2.3; 2.3
-0.8 34;3.4 C5-137
-0.7 2.1; 2.1 1.012.7;2.7 0.7 30;3.0 Ba La 140
-2.5 4.4; 4.5 1.9 1 5.6; 5.6 18.5 10.2:10.5 l
- Results reflect four weekly collections during the month.
O 7-4
LASALLE Table 7.
Surface Water Collection:
Quarterly composites of weekly collections Required LLD: H 3 = 200 pCi/L Units:
pCi/L 1996 Sample Descriplion and Ccncentration Collection Period Lab Code Tritium L 21 (C) filinois River at Seneca 1st Quarter LS W.1577 349 1 90;101 2nd Quarter LSW. 4039 220 1 85;90 3rd Quarter LSW. 6524,5 187 1 63;66 4Ih Quarter LSW 9494 616 1 104;134 LdLIllinois River Downstream 1st Quarter LSW 1578 380 1 91;105 2nd Quarter -
LSW. 4040 169 i 83;86 3rd Quarter LSW. 6526 164
- ss; 91 4th Quarter LSW 9495 384 1 96;109
(
75
LASALLE lable 8,
Well Water Collection:
Quarterly itequired LL11 113 = 200, Mn 54 = 15, Fe-54 = 30, Co-58 = 15, CoWI = 15. Zn-6; n 30, Zr-Nb 95 = 15, Cs 134 = 15, Cs 137 18, Ba La 140 = 15 pCi/L Units:
pCi/L Sample Description and Concentration L 27 LSCS Onsile_h'e.lj Date Collected 01 02 96 04 02 96 07-02-96 10-02 06 l
Lab Code LWW 5i LWW-1855 LWW 4402 LWW-6925 1
11 3
-351 76;76 23 1 71;71 44 i 85;85 124 1 83;85 Mn 54
-0.611.5;1.5
-0612.0;2.0
-0.511.7;1.7 0.111.8;1.8 l~e-54
-0.6 3.8; 3.8 2.4 4.5; 4.5 1.1 1 4.5; 4.5 1.1 46;4.6 Co-58 0.4 1.8; 1.8
-0.512.0;2.0 1.31 2.1;2.1 0312,2;22 Co 60 0.411.7;1,7 0.4 2.4; 2.4 1.6 1.7; 1.7
-0612.0;2.0 Zn-65
-5.8137;3.8 10.9 5.3; 5.5 0.71 4.0;4.0
-5.4 4.4; 4.5 Zr Nb 95
-0.9 2.3; 2.3 1.2 i 2.8; 2.8
-2,312.9;2.4 1.5 3.1; 3.1 Cs.134 0.411.8;1.8
-1.412.6;2.6 0 8.t 1.9; 1.4 1.2 2.4;2.4 Cs 137
-0.211.7;1.7 1.012.5;2.5
-0.911.9;1.4 1.4 ! 2.3; 2.3 Da La 140 2.715.9;5.9 0.4 35;3.5 3.5 5.0; 5.0
-36 5.5;5.5 L-28 Man.eilles Well Date Collected 01-02-96 04 02-96 07-03-96 10-02 46 Lab Code LWW-52 LWW-1856 LWW 4403 LWW-6426.7 1
11 3 24 1 93;43 34 1 73;73 44 85;85 2 55;55 Mn 54
-0.2 1.4 ; 1.4 06 1.9; 1.9
-0.412.1;2.1 0.8 1.5; 1.5 fe 59 3.213.8;3.9 2.614.0;4.0 3.S i 5.6; 5.7 04 4.4; 4.4 Co-58 0.511.8;1.8 0812.0;2.0
- 0. 2 2.6; 2.6 0511.8;1.8 Co-60 0.21 1.8;1.8 1.0 i 2.1; 2.1 0.211.8;1.S 0.2 2 1.6; 1.6 Zn-65 1.413.4;3.4
-0.724.3;4.3 2.5 4.0; 4.0
-1.2 3.2:3.2 Zr Nb 45 0.6 1 2.2; 2.2 1.5 2.3; 2.3 1.6 1 3.5; 3.5
-1.112.3;2.3 l
Cs-134 0.111.7;1.7
-0.2 2.3;2.3 2.112.4;2.4 0.2 2.1;2.1 1
Cs-137 0.421.6;1.6
-3.6 2,2;2.3 1.0 2.4; 2.4 1.6 1.s; 1.8 Da-La-140 3.215.6;5.6
-3.5 3.3; 3.3 6.5 6.1; 6.1
-2.2 6.s; 6.8 0
l S-1
. -_