LER 83-038/03L-0:on 830627,during Turbine Driven Auxiliary Feedwater Pump Inservice Test,Pump Failed to Start from Train a Steam Supply & Declared Inoperable.Caused by Valve HV-3226 Failing to Stroke properly.W/830726 Ltr
ML20024D087
Person / Time
Site: Farley Southern Nuclear icon.png
Issue date: 07/26/1983
From: Clayton F, Hairston W
ALABAMA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
LER-83-038-03L, LER-83-38-3L, NUDOCS 8308030145
Download: ML20024D087 (3)


Text

  • ..

e ec PereJ ss u o. nucLean estuLarsav enumersism APPAOVED WY OMJ Pone c,id so LICENSEE EVENT REPORT 3'5840" CONTROL BLOCK: l l l l l l@ (PLEASE PRINT OR TYPE ALL REoulRED INFoRMATioN) l oli l. l. A lLLIClJEN.El M

, l F ] 1 l@l0 l0 l- l 0LIClEN.E E CooE l. 9.

0 lNUM 0 BlE0l R

0l -l0 l 0 l@l 4 l 1l 1l 1l1 l@l

.. .. LIC E NP E T V ,E ..

l

., CAT ..

l@

CON'T l o l1 l ";gg l L l@l 0 l 5 l 0l 0l 0l 3 l 4 l 8 l@l0 l6 l2 l 7 l 8 l 3 l@l0 l 7 l 0i 6 l 8 l 3 l@

y g .. .s ..CM E T NWM B E R .. .. EV ENT . ATE .. .. R E,oN T . AT E ..

EVENT DESCRIPTION ANO PROBABLE CONSEQUENCES h l o l2 l l At 1915 on 6-27-83, during the performance of FNP-1-STP-22.16 (Turbine Driven l l0 l3 l l Auxiliary Feedwater Pump Inservice Test), the TDAFWP was declared inoperable when]

lo l4 l lit failed to start from the A train steam supply. Tech. Spec. 3.7.1.2. in part, l lo15ll requires the TDAFWP to be operable. Tech. Spec. 3.7.1.2 action statement re- l l o l s l l auirements were met. Health / safety of the public was not affected. l loI7ll l loIeil l

'an" 'c'M"

. t"#E co-,oNENTcooE

.o'. c"le . "'M "E lo l9 l l Cl Hl@ lE l@ l X l@ lVl Al Ll VlE lX l@ l Fl@ l Dl@

-E,EN,,E..  :' o":,"'..' """"'"**

""?"' "".'.'*"

@ h,*,""',,

l 8i 3l ..

l-l l 01 3l 8l l/l l0 l 3 l l Ll l-l l 0l a n'*" '.11""" ."It?s '" ;",t"" .. .. @ ^!a:","1T ,o"I"!J.. '".'O't,6,i"'-

  • n 27ts",'E.@

lx l@l zi@ L..z_lO Iz l@ lolololof

,, .. L.v_J @ lNl@ l A l@

l Hl 0l 3l 5l .,

CAUSE DESCRIPTION AND CORRECTIVE ACTIONS b27 l i l o l l Following a determination that tTris event was due to valve HV-3226 (Steam Supply l l 1 l 1 l l to TDAFWP) failing to stroke properly, a stroke time test, FNP-1-STP-21.1 (Main l 1112 l l Steam Isolation Valve Operability Test). was performed on the valve. This test l 1 3 l was nerformed satisfactorily. The TDAFWP was declared operable at 2130 on l l 114 l l 6-27-83 following the satisfacto ry performance of FNP-1-STP-22.16. Subsequent l

',le ,Lin

.T.Tv. s...E. of-E. .T .eu. icovE

@ l o [Bj@lSurveillanceTest E.T oo .o,,

o . cove., E.c.

(See@ Attached) "

Tion l115llEl@l1l0l0!@l

, . . .. i...

NA l RELE .E. nELEasE AMOUNT o, ACTgygTV l 1 l 6 l l.1] @ l_Zj@l NA l l NA l NUMBER TV E oE.CRI, TION NA 11171i o f ol ol@lz l@l

.. .. i. ..

l

,E N.ONNEL INJURIE.

NA l I il 81 L.o I o "l ol@l Mg ii .. ..

'i,f" *" *.'E .u"/T o'." * '"@

i 119 l l z l@l" NA g( l 830803'0145 830726

~

i.'.u RI?"'cE .'e'.Q

. Tion PDR ADOCK 05000348 NRC USE ONLY PDR l 2 l o l l N I@l

, . . i.

llll[lll((lll NAME OF PREPARER W. G. Hairston, III psoye. (205) 899-5156

,n .

4 .... .

(

Licensee Event Report LER 83-038/03L-0 Page 2 of 2 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS disassembly of.the valve to repair body to bonnet leak rev'ealed no cause

'for'the failure.

d 4

t f

i 1

t 7

1 i

I 7

i

, , . , . , - . _ ..___.,.,,......__m. , ,. . _ _ ,. .._ . . . -,.. .. . . . _ , _ , . . . . . _ . ,, . . _ . , _ _ _ ,_ _ _ , . ~ ,_- , , _ .._ . _ . . , _..

Rbiting Addrns Alabama Power Company 600 North 18tn Street U$$,

Post Office Box 2641 4 h ' 8 -T(,' ..

Birmingham, Alabama 35291 -

Aj 7 - 'C. ,.

Teleptohe 205 783-6081 '

..;-// ..

F. L Clayton, Jr.

/

Senior Vice President Fhntndge Build:ng [g'/ p & p 11n? sauttum chxtnc sy .

July 26, 1983 Docket No. 348 U. S. Nuclear Regulatory Commission Of fice of Inspection and Enforcement Region II 101 Marietta Street, N.W.

Suite 3100 Atlanta, Georgia 30303

Dear Sir:

Joseph M. Farley Nuclear Plant, Unit 1, Licensee Event Report No.

LER 83-038/03L-0 is forwarded with three (3) copies in accordance with FNP Technical Specification 6.9.1.13 to provide thirty (30) days written noti-fication of the occurrence.

If you have any questions, please advise.

Yours very truly, hf '

F. L. Clayton, J r.

FLCJ r/KWM:nac Enclosures xc: Director, IE (30 copies)

Director, MIPC (3 copies) bb[4,Lff'P]l 4A