ML19340A145

From kanterella
Jump to navigation Jump to search
Forwards Amend to BAW-1432 & Proposed Tech Specs Changes
ML19340A145
Person / Time
Site: Oconee Duke Energy icon.png
Issue date: 10/20/1976
From: Powell E
DUKE POWER CO.
To: Schwencer A
Office of Nuclear Reactor Regulation
Shared Package
ML19340A146 List:
References
NUDOCS 8001100611
Download: ML19340A145 (3)


Text

{{#Wiki_filter:_ _____ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

    'NRC potu 195                                                 u.c. NUCLEAn REGULATORY Cr      'ISS IO N 00CKET NUMOER (2 788                                                                                                         50-287 NRC DISTRIBUTION Fon PART 50 DOCKET MATERI AL TO:                                                 FROM:                                               DATE OF DOCUMENT Duke Power Company                                       10/20/76 Mr. Senard C. Rusche                           Charlotte, North Carolina                         o4TE REcEivEo E. D. Powell                                             10/26/76 MLETTEA                 MOTORIZED                   PROP                       fNPUT PORM               NUMBER OF COPIES RECEIVED JEORICINAL           MUNCLASSIFIE o                                                                      Three si;;ned C co"                                                                                                37 conies enci reevd.

DESCnlPTioN ENCLOSU R E Ltr. re their 7/21/76 ltr....notori:cd 10/20/76. ...trans the following: Attachment 1: Amendment to 3A'I-1432 _ Oconee 3, Cycle 2 _- Reload Report October 20, 1976 Attachment 2:

                                                      ~]
                                                   '~~~

Proposed Revisions to Ceonee Nucl' ear S tation Technical Specifications

                              ~

October 20, 1976 Oconee Unit 3 (2-P) (19-P) 5 SAFETY FOR ACTION /INFORMATION ENVTRo 10/27/79 'tJL

.I ACSICNED AD: . , h ASSICNED AD!

X BRANCH CHIEF: Scnuencer (,f")

                                                              '      ~

BRANCH cnTEF.  ! V PROJECT MANAGER: Zech PROJECT MANAGERr I V LIC. ASST.: sheppard LIC. ASST.? M Afe d~nw d - v _-A INTERNAL OlSTRIBUTION VTLES FILV SYSTEMS SAFETY PUNT KYSTFun SITE SAETY & XMC 7D1C _ HEINEMAN TFnescn ENVIRO ANALYSIS X I&E (p ) SCHROEDER BENAROYA DENTON & VUTT.cR 6 X

                       ~

OELD MINAS X GOSSICK & STAFF ENGINEERING IPPOLITO ENVIRO TECH _ MIPC MACCARRY KIRKWOOD FRNST CASE KNICHT BALMRD I HAN/.UER SIHWEIL OPERATING REACTORS SPANcTTR HARLESS PAWLICKI ST2LLO RTTY T7t'TR_ PROJECT MANAGEMENT REACTOR SAFETY OPERATING TECH. CAMMTLL BOYD ROSS Y EISENHiTr ( l G ./ STEPP P. COLLINS NOVAK V SHA0 M1TLMAN H0_U_S_ TON ROSZTOCZY M BAER PETERSON CHECK V B1TrLER SITE ANALYSIS i MELTZ f CRIMES VOT.T MER iHELTEMES AT & I BUNcM I SK'0VHOLT SALTZMAN y .T. COT.T.TNM RUTBERG tcRFcFR l EXTERNAL DISTRl0UTION CONTROL NUMBE R ! $LPDR: Tal5alla. 9.C. NAT MB: BROOKE E U AT M B t M TIC: REC. VIE ULRIKSON(ORPO

    % sic.                                  tA_ PoR                                                                  /oE/ 7                                        /

i ASLB; . CONSULTANTS [ACRS/kCY,S ::^ .;;;e/SENT . T//#A-dddM -* R90s -{ j Cc FonM ton (2 M3

 . ,-        ~                            r                                          R l

DUKE PowEn COMPANY Powra Bettnixo 422 SocTu Cut acu SrazzT. CnAntoTTr. N. C. ae24a

c.o neweuu October 20, 1976 Alss?an? /icg Ant %
QtN' TCLE***0NE. &# Ea 704 Ps0cgf GN a Q TeaNSw'S S'QN 374-4682
                                       -.n.,.                                                a..   \@

i Mr. Benard C. Rusche, Director ig# l Office of Nuclear Reactor Regulation Y ' U. S. Nuclear Regulatory Commission - 20555 Washington, D. C. OCl26[hp si l Attention: Mr. A. Schwencer, Chief Operating Reactors Branch No. 1 hUS*h#'d y [

                                                                                                                  'e l           Re: Oconee Unit 3                                                                       %

Docket No. 50-287 l

Dear Sir:

My letter dated July 21, 1976 proposed revisions to the Oconee Nuclear Station Technical Specifications to assure the operation of the Oconee 3, Cycle 2 core within acceptable fuel design and performance criteria. Subsequent to this submittal, it has become necessary to replace four of the proposed replacement fuel assemblies with those of a slightly different enrichment. Attachment 1 provides an amendment to Babcock & Wilcox Report BAW-1432, "Oconee Unit 3, Cycle 2 Reload Report" which demonstrates the acceptability of this action. Pursuant to 10CFR50, 550.90 proposed changes to the Oconee Nuclear Station Technical Specifications are requested which will provide for the operation of Oconee Unit 3, Cycle 2 with the above changes. These revisions are incor-porated in the revised figures shown in Attachment 2. I Very truly yours,

                                                                                 ,- & ~

s ne' Q p f , L E. D. Pcvell ,'

                                                                        /'       :q(3 MST:ge                                                      d               "            ~
                                                                       'Ic 9
Attachment (s) 10819

. . O O, Mr. Benard C. Rusche Page 2 October 20, 1976 E. D. POWELL, being. duly sworn, states that he is Assistant Vice President of Duke Power' Company; that he is authorized on the part of said Company to sign and file with the Nuclear Regulatory Commission this request for amendment of the Oconee Nuclear Station Facility Operating Licenses DPR-38, DPR-47, and DPR-55; and that all statements and matters set forth therein are true-and correct to the best of his knowledge.

                                                                  .g E. D. Powell, Assistant Vice President                         REcB/E0'>
                                                             /U OCi h 1976 3 y'f v.s.eccue  nu m y/
                                                                      $=Ys$$"       ,Q?

ATTEST: / 1 C. Goodman, Jr. / sistant Secretary Subscribed and sworn to before me this 20th day of October, 1976. bts ( M J) % ,/ Notary Public My Commission Expires:

         /f M , 2 d M '1
  • 10819
                          /
   ,          ,                                                             _ . _ _  _}}