Jump to navigation Jump to search
Notice of Violation from Insp on 891016-20.Violation Noted: on 891018,auxiliary Operator Entered Safety Injection Pump Room B & Proceeded to Climb in Areas Posted as Contaminated W/O Wearing Required Full Protective Clothing
ML19325E935
Person / Time
Site: Waterford Entergy icon.png
Issue date: 11/03/1989
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
Shared Package
ML19325E934 List:
References
50-382-89-35, NUDOCS 8911130049
Download: ML19325E935 (1)


Text

w

, [c APPENDIX A NOTICE OF VIOLATION

' Louisiana Power & Light Company Docket:

50 382 Waterford Steam Electric Station, Operating License: NPF-38 Unit 3

~

a During an NRC inspection conducted on October 16-20, 1989, a violation of NRC requirements was identified. The violation involved a failure to take adequate corrective action with regard to following radiation protection procedures.

In accordance with the ' General Statement of Polic and Procedure for NRC Enforcement Actions," 10 CFR Part 2. Appendix C (1989) y(Enforcement Policy), the violation is listed below:

Failure to follow Radiological Protection Control procedures Technical Specification 6.11.1 requires, in part, that approved procedures for personnel radiation protection shall be adhered to for all operations involving personnel radiation exposure.

Paragraph 4.8.6 of approved radiation protection Procedure HP-1-110, Fevision 8. " Radiation Work Permits," requires observing and abiding by radiation work permits and posted radiological signs.

Standing Radiation work Permit (RWP) 89000002 requires full ant 1 contamination protective clothing when climbing in a contaminated area.

Contrary to the above, on October 18, 1989, an auxiliary operator entere<1 the Safety injection Pump Room B and proceeded to climb in areas posted as contaminated without wearing the required full anticontamination protective clothing.

This is a repeat of a violation that occurred on May 26, 1989.

This is a Severity Level IV violation.

(Supplement 1)(382/8935-01)

Pursuant to the provisions of 10 CFR 2.201 Louisiana Power & Light Company is hereby required to submit to this office, within 30 days of the date of the letter transmitting this Notice, a written statement or explanation in reply, including for each violation:

(1) the reason for the violation if admitted.

(2) the corrective steps which have been taken and the results achieved.

(3) the corrective steps which will be taken to avoid further violations, and (4)thedatewhenfullcompliancewillbeachieved. Where good cause is shown, consideration will be given to extending the response time.

Dated at Arlington, Texas, yy/tc6 day of f/gf @ pd ot/1989 this 0911130049 891103 ADOCK 0500 2

gDR l