. NRC FORM 366 U. b. NUCLtAH HtGUL AIUHY CUMM15SIUN (7 77)

LICENSEE EVENT REPORT ,

CONTROL BLOCK: l 1

l l l l l 6

!h (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION)

ITTTl l Mi 0l c ci Ni zig l 0 l 0 i -l 0101010101 - 10 l 01@l 4 l 111 l 1111@l l lg 7 8 9 LICENSEE CODE 14 15 LICENSE NUMBER 25 26 LICENSE TYPE 40 57 CAT 68 CON'T o

7 5

8 s$ % l60L l@l61 0l 5 l 010 l 0l 3 l 1 l 868l@l691 l 211 DOCKET NUM8ER l 217 l 974l@ 750 l 1REPORT EVENT DATE l 013 l 8 l O80 l@

DATE EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h O 2 l At 0705 Channel A wide range nuclear Instrument (WRNI).was discovered to l 0 a i be malfunctionino. The instrument was olaced out of service in accordance O A t wi th T.S . 3.3.1.1. The three redundant WRNI channels remained operable l 0 s I during the event. Channel A WRNI was returned to service at 1630. This l g l is not a repetitive occurrence.

O 7 l O 8 l  !

7 8 9 80 DE CODE 5 BC E COMPONENT CODE SU8 CODE SU E O 9 ltlcl@ LE_j@ W @ l I N IS IT R lU @ lE l@ Q @

7 8 9 10 11 12 13 18 19 20

_ SEQUENTIAL OCCORRENCE REPORT REVISION L E R / RO, EVENT YE AR R EPORT NO. CODE TYPE N O.

@ , reg

_ l217 22l9 l-l 23 l0l4 3l 24 26 l/l 27 l0 l3 l 28 29 lL 30 g

31 l0 l 32 K N A O ON PLANT ME SOURS 22 SB i POR 8. $UPPLI MANUFAC RER L8_l@

33 34 W@ lzl@

35 l_z_j@

36 IOl0l0 uI 33 40 LY_J @

41 lYl@

42 43 Nl@ l44W l 1 l 2 l 047 l@

CAUSE OESCRIPTION AND CCARECTIVE ACTIONS h i o l The problem was found to be a lack of fission chamber current from the Ch.

LLLLJ l A Wide Rance detector. This was caused by the center ein in a connector' I

, , having parted from the fission chamber extender cable conductor. Lack of i i a l fission chamber current caused erratic indication. I i 4 l l

's#M7s*

A sPowER OrsER STATUS @ oisERv' DisCOvERv oEsCRiPTiON @

i s J @ l0l0l0l@l NA . l -l A l@l Ooerator Observation l A TlVITY CO TENT RECE ASED OF RELEASE AMOUNT OF ACTIVlW -

L'OC ATION OF RELEASE -

1- 6 NA l NA

@ .LZ_J@l l PERSONNEL EXPOS ES NUMSER TYPE DESCRIPTION i 7 I0 01 Ol@l Zl@f" NA l PERsONNE L iN;u'R'iEs

  • NUM8FR DESCniPtiON 7

1 s 8 9 l Ol 0 Ol@l 11 12 NA 80

= '

wPE ' es=T Jr^o"" @

i 9 IZI@l NA 1707 211 7 8 9 to 80 ISS

  • LuoJ8, l9 NEI'8lDE CRIPTION NA 8001090 3 m  ;  ;;;;;;;;;;;jjg 7 10 68 69 '
  • 80 ~

NAME OF PREPARER PHONE:

LER NO. 79-43/3L DOCKET NO. 50-318 EVENT DATE 12/4/79 REPORT DATE 1/2/80 ATTACHMENT CAUSE DESCRIPTION AND CORRECTIVE ACTION: (CONTIN.UED)

The connector was repaired, and satisfactory indication was restored.

- Detector and extension cable connectors are routinely disconnected and tested or cleaned. It is believed that this type of failure is an effect of the wear and deterioration-normally expected to occur through handling. This type of failure has not been repetitive, th6refore, no preventive action is presently -

being taken to prevent recurrence.

b 1707 212 9

9