ULNRC-05908, Responses to Requests for Additional Information (RAI) for Severe Accident Mitigation Alternatives

From kanterella
(Redirected from ML12269A164)
Jump to navigation Jump to search
Responses to Requests for Additional Information (RAI) for Severe Accident Mitigation Alternatives
ML12269A164
Person / Time
Site: Callaway Ameren icon.png
Issue date: 09/24/2012
From:
Ameren Missouri
To:
Office of Nuclear Reactor Regulation
Shared Package
Ml122690189 List:
References
ULNRC-05908
Download: ML12269A164 (173)


Text

ULNRC-05908 September 24, 2012 Enclosure 1 Page 1 of 77 License Renewal Application Requests for Additional Information (RAI) Responses for Severe Accident Mitigation Alternatives for Callaway Plant, Unit 1

1. Relative to the Level 1 Probabilistic Risk Assessment (PRA):
a. Table F.3-1 appears to be a list of accident sequences contributing to core damage frequency (CDF) as it includes anticipated transient without scram (ATWS), station blackout (SBO), and reactor cooling pump (RCP) seal loss-of-coolant accident (LOCA). Provide a list of initiator event groups and their contribution to total CDF. Separately, please provide the CDF for the ATWS, SBO, and RCP seal LOCA sequences. Also confirm that the SBO frequency includes those following a loss of offsite power (LOSP) as well as those following other transients. If necessary, use an initiating event category of "Other" to ensure the list sums to the total internal events CDF.

Response

Table 1.a, below, provides a list of Callaway initiating events, and the contribution of each initiating event to the total internal events CDF.

Table 1.a - Contribution of Initiators to Internal Events CDF Percentage of Internal Initiating Event (IE) IE Description Core Damage Frequency Events CDF IF INTERNAL FLOODING 9.14E-06 35.0%

IE-S2 SMALL LOCA INITIATING EVENT FREQUENCY 5.87E-06 22.5%

IE-T1 LOSS OF OFFSITE POWER INITIATING EVENT FREQUENCY 5.58E-06 21.4%

IE-TSG STEAM GENERATOR TUBE RUPTURE IE FREQUENCY 2.34E-06 9.0%

IE-T3 TURBINE TRIP WITH MAIN FEEDWATER AVAILABLE IE FREQ 1.08E-06 4.1%

IE-S1 INTERMEDIATE LOCA INITIATING EVENT FREQUENCY 3.63E-07 1.4%

IE-TMSO MAIN STEAMLINE BREAK OUTSIDE CTMT IE FREQUENCY 3.54E-07 1.4%

RV Rupt. REACTOR VESSEL RUPTURE 3.00E-07 1.1%

IE-S3 VERY SMALL LOCA INITIATING EVENT FREQUENCY 2.07E-07 0.8%

IE-T2 LOSS OF MAIN FEEDWATER IE FREQUENCY 1.88E-07 0.7%

ISLOCA INTERFACING SYSTEMS LOCA 1.73E-07 0.7%

IE-TC LOSS OF ALL COMPONENT COOLING WATER IE FREQUENCY 1.20E-07 0.5%

IE-TSW LOSS OF SERVICE WATER INITIATING EVENT 1.15E-07 0.4%

IE-TFLB FEEDLINE BREAK UPSTREAM OF CKVS IE FREQUENCY 9.75E-08 0.4%

IE-TDCNK01 LOSS OF VITAL DC BUS NK01 INITIATING EVENT FREQUENCY 4.84E-08 0.2%

IE-A LARGE LOCA INITIATING EVENT FREQUENCY 4.21E-08 0.2%

IE-TDCNK04 LOSS OF VITAL DC BUS NK04 INITIATING EVENT FREQUENCY 3.13E-08 0.1%

IE-TMSI MAIN STEAMLINE BREAK INSIDE CTMT IE FREQUENCY 1.54E-08 0.1%

IE-TFLD FEEDLINE BREAK DOWNSTREAM OF CKVS IE FREQUENCY 1.43E-09 0.0%

Total Internal Events CDF: 2.61E-05 100%

ULNRC-05908 September 24, 2012 Page 2 of 77 The CDF for ATWS sequences is 3.14E-7, or 1.2 percent of the internal events CDF. The CDF for station blackout is 4.71E-6, or 18.0 percent of the internal events CDF.

RCP seal LOCAs are explicitly addressed in the Callaway PRA in two ways.

First, for non-LOCA transient initiators, a heading is placed early in the event tree to screen for loss of RCP seal cooling. Sequences involving loss of seal cooling are then evaluated / quantified as RCP seal LOCA sequences. The CDF from these RCP seal LOCA sequences is 8.35E-7, or 3.2 percent of the internal events CDF. Second, in certain support system initiator sequences (e.g., loss of all Component Cooling Water, followed by loss of the Normal Charging Pump (NCP)), an RCP seal LOCA is assumed to occur, and is addressed within the given event tree. A third category of RCP seal LOCAs, i.e., seal LOCAs that represent an initiating event, is not explicitly modeled in the Callaway PRA, but can be taken to be included in the Very Small LOCA initiating event category.

ATWS and RCP seal LOCA CDF values, as reported in Table 3-1 of the Environmental Report, have been updated to 3.14E-7 and 8.35E-7 respectively, as stated above.

In the internal events model version used in the SAMA analysis, station blackout sequences are initiated only by the loss of offsite power initiator. (In the upgraded Callaway internal events PRA model, consequential loss of offsite power events, following a loss of main feedwater or reactor trip initiator, are modeled, and can progress to station blackout. In this model, consequential LOOP accounts for approximately 28 percent of the SBO frequency. In addition, consequential LOOP-initiated SBO accounts for 2.5 percent of CDF. Thus, even in the upgraded internal events PRA, station blackout risk is dominated by the loss of offsite power initiator.)

The internal flooding analysis included in PRA Update 4B addresses ATWS and SBO. To simplify the quantification of internal flooding, ATWS sequences are assumed to go directly to core damage. Flooding-initiated sequences that result in SBO would be included via the combination of flood-induced equipment failures and random equipment failures. Note that flood-initiated ATWS and SBO CDF are reported within the Internal Flooding CDF category.

b. The internal events CDF is given as 1.66E-05 per year on page F-11. The CDF for the apparent latest revision, Update 4B, is given as 2.61E-05 per year on page F-20. While this difference may be due to exclusion of internal flooding (9.14E-06 in Table 3-4) from the 1.66E-05 value and inclusion of it in the external events multiplier, adding this value for internal floods to the Table 3-1 value yields 2.57E-05, which is close but not equal to the 2.61E-05 value. Provide the basis for the difference in these calculated values and the rationale for the value used in the SAMA analysis. Include discussion of how initiating event contributors were accounted for in each total value.

ULNRC-05908 September 24, 2012 Page 3 of 77

Response

The difference in the cited calculated values is due to the inclusion, or not, of the reactor vessel (RV) rupture event in the CDF results. RV rupture is assumed, in the Callaway PRA, to go directly to core damage. A reference frequency of 3E-7 per year is used, in Update 4B, for this event. If the RV rupture frequency is added to the 2.57E-5 value, cited above, the resulting CDF is approximately, i.e.,

within round-off, the 2.61E-5 value, or the overall Update 4B internal events CDF.

The SAMA analysis essentially uses the 1.66E-5 value, with a multiplier of 4.57 applied to account for external events (refer to the discussion in section 3.1.2.4 of Attachment F). The basis for this approach is that the 1.66E-5 value is the baseline internal events CDF, which is essentially the value perturbed when performing sensitivity analyses in support of the SAMA analysis. All internal initiating event contributors, except for internal flooding and RV rupture, are accounted for in the 1.66E-5 value. Internal flooding is accounted for via use of the 4.57 multiplier. RV rupture is not accounted for in the SAMA analysis. This is acceptable as RV rupture is a singular event that is assumed to go to core damage, and whose probability/frequency would not be directly affected by SAMAs.

c. Provide the truncation value used for each PRA.

Response

The truncation value used for quantification of the Level 1 internal events PRA used in the SAMA analysis is 1E-12.

d. Provide further discussion of the steps taken to ensure the technical adequacy of the Level 1 PRA subsequent to the 2000 Westinghouse owners group (WOG) peer review. Specifically include in this discussion:
i. Further support for the disposition of peer review facts and observations (F&Os)

IE-7 and ST-1 as described in Table 3-8 of the SAMA submittal.

Response

Further support for the disposition of WOG F&Os IE-7 and ST-1, relative to the SAMA analysis, is provided below.

IE-7:

This F&O provided two comments on the ISLOCA analysis.

The first comment primarily questions whether there could be ISLOCA locations inside containment, which could lead to loss of mitigating system (presumed to be ECCS recirc.) function. This comment was investigated, and determined not to be valid for the following reasons:

1. Various documented ISLOCA definitions, e.g., that provided in SR IE-A2, item (d), of the PRA Standard, either explicitly state, or imply, that

ULNRC-05908 September 24, 2012 Page 4 of 77 ISLOCAs occur outside containment.

2. For any LOCA location inside the Callaway containment, the water exiting the break will drain to one of the two safety-related containment sumps, and then be available for ECCS recirculation.

Since the F&O comment was determined not to be valid, as described above, there is no associated impact on the SAMA analysis.

The second comment of this F&O is related to the lack of treatment of parametric uncertainty in the ISLOCA analysis. The concern expressed was that this could be important for redundant isolation valves, in an ISLOCA flowpath, that used the same failure rate.

As noted in Table 3-8 of Attachment F, this second F&O comment/issue does not bear negatively on the SAMA analysis. ISLOCA is a very minor contributor to the Callaway internal events CDF (approximately 1%). In addition, the treatment of uncertainty in the SAMA analysis, as described in section 8.2 of Attachment F, is sufficiently conservative so as to bound any impact on the ISLOCA CDF associated with this F&O comment.

ST-1:

This F&O suggests using a reference such as NUREG/CR-5744 to determine the probability of low pressure piping failure upon overpressurization. The F&O states that the reviewers were not familiar with the reference that was used to perform this determination.

This F&O was addressed in an updated ISLOCA analysis performed for PRA Update 5. The methodology in the suggested NUREG was used to determine the probabilities of failure of RHR and SI piping on exposure to RCS pressure.

The failure probability of RHR piping on exposure to over-pressure did not change. The failure probability of SI piping increased; however, the overall ISLOCA CDF determined in Update 5 was similar to, and less than, the ISLOCA CDF of Update 4B. The results of the ISLOCA analyses are summarized in the Table 1.d.i, below.

Table 1.d.i - ISLOCA CDF Comparison Internal Events PRA Version ISLOCA CDF (yr-1)

Update 4B 1.73E-7 Update 5 1.49E-7 Since the overall ISLOCA CDF results are similar, and, in fact, the Update 4B ISLOCA CDF is slightly greater than that for Update 5, WOG F&O ST-1 does not bear negatively on the SAMA analysis.

ULNRC-05908 September 24, 2012 Page 5 of 77 Note that both the ISLOCA analysis used in PRA Update 4B and the updated ISLOCA analysis of PRA Update 5 include the potential for common cause failure of redundant MOVs and redundant check valves in ISLOCA flow paths.

ii. A description of the findings of the 2006 review against the 2005 revision of the American Society Mechanical Engineers (ASME) PRA standard and the disposition of any deficiencies for the SAMA application. Attachment U of the National Fire Protection Association (NFPA) 805 Licensing Amendment Request (LAR) provides this information relative to the fire risk application.

Similar information is needed for the SAMA application including disposition of open findings.

Response

Table 1.d.ii, below, provides a listing of the gaps between the Callaway internal events Level 1 PRA used for the SAMA analysis and applicable Capability Category II requirements of the 2005 revision of the ASME PRA Standard. The table also provides a disposition of each of the gaps relative to the SAMA application.

ULNRC-05908 September 24, 2012 Enclosure 1 Page 6 of 77 Table 1.d.ii Comparison of Callaway Internal Events Level 1 PRA Used in the SAMA Analysis to Applicable Capability Category II Requirements of the ASME PRA Standard Supporting Associated Requirement Finding/ F/O Level of (SR) Not Met at F/O Description F/O Disposition for SAMA Application Observation Significance Capability (F/O) No.

Category II IE-A4 IE-3 C No documentation of a system-by-system review System-by-system review has since been performed for IE potential. and documented. No new IEs were identified.

Therefore, there is no impact on the SAMA application.

IE-A5 IE-4 C Non-power events were not evaluated/ Non-power events have since been addressed. No new addressed in the original IE analysis. IEs were identified. Therefore, there is no impact on the SAMA application.

IE-A7 IE-6 B Callaway Plant OE for IE precursors was not Callaway precursor OE has since been reviewed. No reviewed when originally identifying IEs. new IEs were identified. Therefore, there is no impact on the SAMA application.

IE-C1 IE-7 B The IE frequencies do not have uncertainty The SAMA analysis includes a conservative treatment of bounds assigned. uncertainty, as discussed in section 8.2 of Attachment F.

This treatment of uncertainty bounds the anticipated uncertainties in the IE frequencies used in PRA Update 4B.

IE-C1a IE-7 B See discussion for SR IE-C1. See discussion for SR IE-C1.

IE-C1b IE-8 B Certain recovery events, following loss of CCW The credit given (i.e., probabilities used) for the and loss of SW, are credited, without, in the recovery events in question was based on a credible reviewers view, sufficient analysis or data. analysis. Should additional analysis determine different recovery probabilities, the resulting uncertainty would be bounded by the overall treatment of uncertainty applied in the SAMA analysis, which is discussed in section 8.2 of Attachment F.

ULNRC-05908 September 24, 2012 Enclosure 1 Page 7 of 77 IE-C3 IE-10 C Certain IE frequencies are not adjusted to account Adjustment of the IE frequencies in question, to account for plant availability. for plant availability, would result in IE frequencies that are approximately 10 percent lower than those that are not adjusted. Therefore, to the extent that certain IE frequencies in the SAMA analysis do not include this adjustment, the resulting CDF would be conservative.

IE-C9 IE-8 B See discussion for SR IE-C1b. See discussion for SR IE-C1b.

IE-C10 IE-12 B There is no documentation of a comparison of A comparison of all IE frequencies to generic and other fault tree-generated support system IE frequencies plant data was performed and documented for PRA to generic data. Update 5. No IE frequencies were determined to be outliers as a result of this comparison. Therefore, this gap does not negatively impact the SAMA application.

IE-C12 IE-13 B Identified gap is related to documentation and age ISLOCA is only a minor contributor to the Callaway of the Interfacing System LOCA (ISLOCA) CDF. In addition, the ISLOCA analysis was redone for analysis. PRA Update 5 to address gaps to Capability Category II of the ASME PRA Standard. As noted in the response to RAI question 1.d.i, the Update 5 ISLOCA CDF is similar to, and slightly lower than, the Update 4B ISLOCA CDF. Therefore, this gap does not negatively impact the SAMA application.

IE-C13 IE-7 B See discussion for SR IE-C1. See discussion for SR IE-C1.

IE-D1 IE-14 C Finding is that, while IE documentation is This gap was deemed by the review team to be a reasonably complete, it is not conducive to documentation issue. Adequate documentation of the performing updates or peer reviews, primarily IE analysis does exist. This finding does not negatively because the IE documentation resides in a impact the SAMA application.

relatively large number of documents. Finding was categorized by review team as a documentation issue.

IE-D2 IE-14 C See discussion for SR IE-D1. See discussion for SR IE-D1.

IE-D3 IE-14 C See discussion for SR IE-D1. See information for SR IE-D1.

ULNRC-05908 September 24, 2012 Enclosure 1 Page 8 of 77 AS-A11 AS-2 B This finding was based on there being event tree The transfer sequences have been extensively transfer sequences that were quantified with .OCL reviewed, and no issues have been identified.

(i.e., sequence quantification) files that were Therefore, this F/O does not negatively impact the generated manually, and not with a specific event SAMA application.

tree. This was deemed to introduce the possibility of errors, although none were found.

AS-B1 AS-1, AS-3, B, B, C, B, The 4 cited F/Os essentially question whether the A sensitivity evaluation performed for the previously-AS-5, AS-7 respectively impact of certain IEs, on certain mitigation approved one-time ESW Completion Time (CT) functions credited in event trees (ETs), was extension application determined that correction of F/Os correctly captured. AS-1, -3 and -7 would result in only a 1% increase in the Update 4 baseline CDF. (Note also that certain F/O-implied issues were investigated, and could not be verified.) F/O AS-5 suggests re-evaluation of the switchgear room cooling requirements for SBO conditions. It has since been determined that switchgear room cooling is not required for any initiator.

Use of the Update 4B model, which requires room cooling, for the SAMA application, would be conservative.

Based on the above discussion, the gap to Capability Category II of SR AS-B1 would not negatively impact the SAMA application.

AS-B2 AS-1, AS-3, B, B, C, B, See discussion for SR AS-B1. See discussion for SR AS-B1.

AS-5, AS-7 respectively AS-B6 AS-4, AS-5 B, C, AS-4 cites the need to update the RCP seal LOCA AS-5 is discussed above for SR AS-B1. Regarding AS-respectively model. AS-5 recommends re-evaluating the room 4, the seal LOCA model used in Update 4B is based on cooling requirement for switchgear rooms during an older-vintage Westinghouse Owners Group study.

SBO. A previous sensitivity study indicated that baseline CDF would increase by only 1.5 percent when seal LOCA model-related parameters were varied (i.e., increased).

Thus, the AS-4 finding would not negatively impact the SAMA application.

ULNRC-05908 September 24, 2012 Enclosure 1 Page 9 of 77 SC-B5 SC-2 C No documentation of a check of the The review team deemed this to be a documentation reasonableness of success criteria. issue.

The Callaway Plant success criteria are similar to the Wolf Creek success criteria. (Wolf Creek is essentially the same plant design as Callaway.) During development of the original PRA model, for the IPE, periodic comparisons were made of the Callaway and Wolf Creek PRAs, including comparisons of success criteria.

The Callaway Plant success criteria are also comparable to success criteria for other, similar plants.

In addition, for PRA Update 5, the various event tree success criteria were validated using MAAP 4.0.7. No significant changes were identified.

Based on the above discussion, this finding does not negatively impact the SAMA application.

SC-C1 SC-1 C Success criteria are not documented in a single The review team deemed this to be a documentation place. issue. Thus, this gap to Capability Category II of the SR does not negatively impact the SAMA application.

SC-C2 SC-1 C See discussion for SR SC-C1. See discussion for SR SC-C1.

SC-C3 SC-1 C See discussion for SR SC-C1. See discussion for SR SC-C1.

SY-A7 SY-1 B Two issues were identified: (1) the dependency of A sensitivity analysis was performed to address these Main Feedwater on instrument air (IA) needs to be issues for a previous application. The analysis resulted included in the model and (2) the applicability of in only a 0.59 percent increase in the Update 4 baseline data used for undeveloped events for loss of IA CDF. Therefore, this finding does not negatively impact and failure of actuation signals needs to be the SAMA application.

verified.

SY-A22 IE-8 B See discussion for SR IE-C1b. See discussion for SR IE-C1b.

ULNRC-05908 September 24, 2012 Enclosure 1 Page 10 of 77 SY-B1 SY-2 B CCFs are not modeled for battery chargers or Battery charger and breaker independent failure events breakers. In addition, the quantification of CCF have low Fussel-Vesely importances in PRA Update 4.

probabilities should be updated. The F-V importance of CCFs of battery chargers and breakers would also be expected to be relatively low, if these failure modes were modeled. As a sensitivity analysis, battery charger common cause failure events were added to the Update 4 PRA model, and the model was re-quantified. There was no discernable change in core damage frequency. In fact, all battery charger CCF events added to the model were truncated from the core damage cutset results. (A truncation value of approximately seven (7) orders of magnitude below the baseline CDF was used in the PRA quantification.)

A separate sensitivity analysis was performed in which all existing CCF probabilities were increased by 10 percent. The PRA Update 4 baseline CDF increased by only 3.54 percent.

Based on the above discussion, this finding does not negatively impact the SAMA application.

SY-B3 SY-2 B See discussion for SR SY-B1. See discussion for SR SY-B1.

HR-D3 HR-1 C Suggestion for addition of a ground rule The review team deemed this finding to be a statement to HRA documentation. documentation issue. As such, this finding does not negatively impact the SAMA application.

HR-G6 HR-2 C A reasonableness check of HEPs was performed, The review team deemed this finding to be a but not documented. documentation issue. As such, this finding does not negatively impact the SAMA application.

HR-I3 HR-3 C No documentation of key sources of uncertainty The review team deemed this finding to be a associated with the HRA. documentation issue. As such, this finding does not negatively impact the SAMA application.

ULNRC-05908 September 24, 2012 Enclosure 1 Page 11 of 77 DA-B1 DA-2 B Only Capability Category I is met with respect to The data update task performed for PRA Update 5 SR DA-B1. (Components were not grouped grouped components by component type and according to characteristics of their usage.) characteristics of their usage (in order to meet Capability Category II of this SR). The resulting groupings had populations that were similar to the groupings that are the subject of this finding. Therefore, this finding would not negatively impact the SAMA application.

DA-C2 DA-2 B See discussion for SR DA-B1. See discussion for SR DA-B1.

DA-C6 DA-1 C Documentation of certain data collection is lacking. The review team deemed this finding to be a (The reviewer noted, however, that the correct documentation issue. As such, and since no actual information appears to have been collected.) errors were noted, this finding does not negatively impact the SAMA application.

DA-C7 DA-1 C See discussion for SR DA-C6. See discussion for SR DA-C6.

DA-C8 DA-1 C See discussion for SR DA-C6. See discussion for SR DA-C6.

DA-C9 DA-1 C See discussion for SR DA-C6. See discussion for SR DA-C6.

DA-C14 IE-8 B See discussion for SR IE-C1b. See discussion for SR IE-C1b.

DA-D2 DA-3 C No justification is provided for the use of The review team deemed this finding to be a engineering judgment to determine the documentation issue.

probabilities of HYDRAULIC-SYSFAIL, STR-FS, STR-FR basic events. A sensitivity analysis was performed in which the probabilities of the HYDRAULICSYSFAIL and all STR basic events were increased by a factor of 2. The PRA Update 4 baseline CDF increased by only 0.03 percent.

Based on the above discussion, this finding does not negatively impact the SAMA application.

ULNRC-05908 September 24, 2012 Enclosure 1 Page 12 of 77 IF-C2a IF-5 B The SR requires that operator response to floods The Callaway internal flooding (IF) analysis was redone be based on flood area and flood sources. The for PRA Update 5 to update the analysis and address Callaway Plant IF analysis, through Update 4B, gaps to Capability Category II of the Standard. The treats operator response in a generic sense. Update 5 IF CDF is 6.21E-6, or about two-thirds of the Update 4B IF CDF.

Due to the method for inclusion of the IF CDF in the SAMA analysis, i.e., including the IF contribution to CDF in the external events multiplier (refer to section 3.1.2.4 of Attachment F), use of the larger Update 4B IF CDF is conservative. Therefore, the various findings related to the IF analysis do not negatively impact the SAMA application.

IF-C6 IF-3 C Current Callaway Plant flood area screening Refer to F/O disposition discussion for SR IF-C2a.

credits operator intervention for floods that take

>30 mins. Criteria for Capability Category II are not explicitly addressed.

IF-C8 IF-3 C See discussion for SR IF-C6. Refer to F/O disposition discussion for SR IF-C2a.

IF-D5 IF-1 C The flood initiator frequencies are based on Refer to F/O disposition discussion for SR IF-C2a.

generic pipe break frequencies. No plant-specific experience was considered in the determination of flood initiator frequencies.

IF-D5a IF-1 C See discussion for SR IF-D5. Refer to F/O disposition discussion for SR IF-C2a.

IF-E3a IF-2 B Standard specifies a CDF screening criterion of Refer to F/O disposition discussion for SR IF-C2a.

1E-9; existing Callaway Plant IF analysis used 1E-6.

IF-E5 IF-4 B HEPs for operator intervention and mitigation are Refer to F/O disposition discussion for SR IF-C2a.

not based on HRA, as required by the Standard.

IF-E5a IF-4 B See discussion for SR IF-E5. Refer to F/O disposition discussion for SR IF-C2a.

QU-A2b QU-1 B Current PRA does not include an uncertainty Uncertainty is included in the SAMA analysis via the calculation accounting for the state-of-knowledge methodology described in section 8.2 of Attachment F.

correlation. Therefore, this finding does not negatively impact the SAMA application.

ULNRC-05908 September 24, 2012 Enclosure 1 Page 13 of 77 QU-D4 QU-5 C No documentation of a review of non-significant The review team deemed this gap to be a sequences or cutsets. documentation issue. As such, it does not negatively impact the SAMA application.

It is noted that all accident sequences have been reviewed via QR (qualified review) of the event trees, regardless of their frequency. In addition, non-significant cutsets have been reviewed from time-to-time, e.g., following a PRA update, or pursuant to applications.

QU-E3 QU-1 B See discussion for SR QU-A2b. See discussion for SR QU-A2b.

QU-F1 QU-8 C Recommendation to integrate all pieces of the When using Update 4B, separate steps are, in fact, internal events analysis into one quantification required to quantify internal events, internal flooding process. and/or ISLOCA. However, as long as the contribution to risk from each of these sources can be determined (including via the use of multipliers), this finding does not negatively impact the SAMA application.

QU-F2 QU-9 B Some of the typical QU documentation items cited The review team deemed this gap to be a in the Standard do not exist for Update 4. documentation issue. As such, it does not negatively impact the SAMA application.

QU-F4 QU-10 B Key assumptions and key sources of uncertainty The review team deemed this finding to be a are not addressed in a coherent manner in the documentation issue. As such, it does not negatively documentation. impact the SAMA application. In addition, uncertainty is addressed in the SAMA analysis.

QU-F5 QU-12 C No documentation exists of limitations in the The review team deemed this finding to be a quantification process that would impact documentation issue. As such, it does not negatively applications, per the Standard requirements. impact the SAMA application.

QU-F6 QU-11 B Definitions of significant cutset and significant The review team deemed this finding to be a accident sequence, used in PRA Update 4, differ documentation issue. As such, it does not negatively from those of the Standard. Justification of the impact the SAMA application.

alternative definitions used was not justified, as required by the Standard.

ULNRC-05908 September 24, 2012 Enclosure 1 Page 14 of 77 Notes on Table 1d.ii:

1. SR numbers based on the 2005 version of the ASME PRA Standard.
2. Definitions of F/O Significance Levels:

A. Extremely important and necessary to address to assure the technical adequacy of the PRA or the quality of the PRA or the quality of the update process.

(There was no A level F/Os.)

B. Important and necessary to address, but may be deferred until the next PRA update.

C. Marginal importance, but considered desirable to maintain maximum flexibility in PRA applications and consistency in the industry.

D. Editorial or minor technical item, left to the discretion of the host utility.

(No D level F/Os were written.)

ULNRC-05908 September 24, 2012 Page 15 of 77 iii. Discussion of findings from a Human Reliability Analysis (HRA) focused scope peer review. We understand from Attachment U of the NFPA 805 LAR submittal that the internal events HRA modeling has been revised and undergone a focused scope peer review. This peer review is not discussed in the SAMA submittal. Discuss the scope of this review and disposition of open findings.

Response

As noted in Table 3-3 of Attachment F, the Fourth Update to the internal events PRA, i.e., PRA Update 4, implemented an updated human reliability analysis (HRA) for risk-significant human failure events (HFEs). One of the purposes of this HRA update was to address open HRA-related Westinghouse Owners Group (WOG) peer review findings, as the WOG peer review deemed the HRA element to be Grade 2 (refer to page F-32). The updated HRA is also used in PRA Update 4B, the model used in the SAMA analysis.

In 2011, an independent, focused-scope peer review of the updated Callaway internal events HRA was performed. The purpose of the review was to examine updated elements of the HRA relative to the findings from the WOG peer review and with respect to the current (i.e., 2009) version of the Standard for probabilistic risk assessment (PRA). The review concluded that the detailed analyses of risk-significant HFEs appeared to reflect appropriate methods properly implemented. Some observations were made in the course of the review, but were judged to be relatively minor, meriting consideration in further updates to the HRA. The focused-scope peer review of the HRA update did not generate any findings per se. Some observations were made.

All of the observations were judged by the reviewer to be relatively minor, meriting consideration in future updates to the HRA.

e. As a result of the NRC review of the Callaway NFPA 805 submittal, NRC staff has requested the results of sensitivity analyses to show the impact of potentially unacceptable modeling approaches (see PRA RAI-08 on influence weighting factors and PRA RAI-09 on control power transformer credit). Please provide the sensitivity of these unacceptable fire PRA modeling approaches on the calculated th fire CDF. If this NFPA 805 sensitivity is not bounded by the SAMA 95 sensitivity analysis provide the impact of this higher fire CDF on the SAMA evaluation.

Response

PRA-RAI-08a from the NFPA-805 LAR involves the usage of compartment weighting factors for transient fire apportionment. The method used in the Callaway Fire PRA was shown to be within the bounds of the approved NRC methods. The approved NRC method requires that at least one of the 3 weighting factors is set to 1.0 and thus, the total weighting factor is not less than 1.0. The

ULNRC-05908 September 24, 2012 Page 16 of 77 Callaway Fire PRA used a combined minimum weighting factor of 1.15 and therefore is within the bounds of the approved NRC methods. No sensitivity study was performed on this issue for the RAI.

PRA-RAI-09a concerns the use of data from Table 10.1 in NUREG/CR-6850. The Callaway PRA used values from Table 10.1 for probability of spurious operation for components with a control power transformer in the control circuit. New fire test data shows minimal effect of CPTs. The RAI asked for a recalculation of CDF using the spurious operation probabilities from Table 10.2 of NUREG/CR-6850 (i.e., for thermoset cables without CPT). When using the Table 10.2 values, the point estimate of fire CDF increased from 2.04E-5 to 2.67E-5, an increase of 6.3E-6.

The internal events CDF at Callaway is 1.66E-5. The 95th percentile value for internal events CDF is 3.50E-5. This provides an uncertainty factor of 2.11 for point estimate to 95th. The total external events CDF (due to Fire, Internal flood, high winds, seismic) is 5.91E-5. If the uncertainty factor of 2.11 from the internal events is applied to the external events, the 95th percentile of the external events CDF is 1.25E-4. The CDF increase of 6.3E-6 from the CPT sensitivity study performed for PRA-RAI-9a is well within the 95th value for external CDF.

f. Provide the freeze date for PRA Update 4B and include in your response whether there have been any changes to the plant, either physical or procedural, since that date that could have a significant impact on the results. If there have been significant changes that represent an increase in risk, provide the impact of those changes on the SAMA evaluation.

Response

The purpose of PRA Update 4B was to incorporate the Alternate Emergency Power System (AEPS) into the Callaway internal events PRA model. Update 4B was completed in February, 2011, and reflected the as-built, as-operated plant at that time. In addition, Callaway has various programs in place to screen plant hardware and procedure changes for their impact on the Callaway PRA. There have been no physical or procedural changes to the plant, since the completion of Update 4B, that would have a significant impact on the PRA results, or the SAMA analysis.

g. Table 3-2 on page F-13 includes the basic event TORNADO-T1-EVENT with a risk reduction worth (RRW) of 1.031. Please explain the basis for this event being included in the internal events PRA.

Response

The Callaway internal events PRA includes credit for an Alternate Emergency Power System (AEPS). This system is comprised of an off-site facility with both a connection to a Cooperative power line and four (4) 2 MWe diesel-generators.

Following certain loss of offsite power events, with subsequent failure of the on-

ULNRC-05908 September 24, 2012 Page 17 of 77 site, safety-related emergency diesel-generators, AC power can be manually aligned, from either the Cooperative power line or the 2 MWe diesel-generators, to one of the 4160 VAC safety-related electrical busses. However, should the loss of offsite power have been caused by a tornado, it is assumed that AEPS is not available. Thus, the TORNADO-T1-EVENT basic event, which represents the conditional probability that the LOOP event was caused by a tornado, is used in the internal events PRA to fail the AEPS.

The probability of this event is determined as follows:

P(tornado) / P(LOOP) = 5E-4 / 1.6E-2 = 3.125E-2, where P(tornado) is taken from page 2.3-7 of the Callaway FSAR Site Addendum. (Note that this same tornado frequency is used in the estimation of tornado-initiated CDF of section F.3.1.2.3, and is referred to in the response to RAI 3.b.)

2. Relative to the Level 2 PRA:
a. The 5th bullet in Section F.3.2 indicates that the sequences that contribute to large early release frequency (LERF) were determined based on source term calculations using Modular Accident Analysis Program (MAAP) 4.0.7. Please provide the basis for the source terms for the other release categories.

Response

All source terms were determined using MAAP 4.0.7, with the results from MAAP used to categorize the sequences as LERF or non-LERF per the ASME PRA Standard.

b. The last paragraph in Section F.3.2 states There were no changes to major modeling assumptions, containment event tree structure, accident progression, source term calculations or other Level 2 attributes, used in the individual plant examination (IPE) Level 2 analysis, when developing the initial and updated models. Justify this statement in light of the many apparent changes discussed previously in this section and in the disposition of the Level 2 Peer Review Facts/Observations (F&Os) in Table F.3-8, or provide a discussion of the changes.

Response

This statement is referring to the individual plant examination (IPE) Level 2 analysis, Initial LERF Model in 2000 (first row of the table) and Updated LERF Model in 2002 (second row of the table). The changes discussed previously in that section and in the disposition of the Level 2 Peer Review F&Os in Table F.3-8 refer to changes between the IPE Updated LERF Model in 2002 (second row of the table) and the Updated full Level 2 Model in 2011 (last row of the table).

c. Provide a description of the containment event tree (CET) or trees used in the level 2 analysis including a listing and description of the CET nodes. Include a description of how phenomenological events and containment system failures are addressed in the CET.

ULNRC-05908 September 24, 2012 Page 18 of 77

Response

Section 2.2 of the Callaway Level 2 Analysis is provided in Enclosure 2, and describes the containment event tree structure.

d. Section F.3.4 identifies eight release categories. Provide further information on each release category including: category definitions and their bases; how the CET end states are assigned to release categories; a description of the sequences that are the major contributors to each release category; the basis for the selection of MAAP case used for each release category; and a description of the MAAP cases used. Also, if the source terms for each release category are not bounding, then provide justification of how the impact of higher source term sequences are accounted for in determining the benefit of potential SAMAs, or provide a sensitivity analysis using bounding case source terms.

Response

Sections 2.5 and 3.1 of the Callaway Level 2 Analysis are provided in Enclosure

2. Sections 2.5.1 and 2.5.3 provide the release category definitions and bases.

CET endstate assignments are included in Section 2.5.2 (also see CET in previous RAI). Major contributors to each release category are included in Section 3.1.1 of the Level 2 report.

A unique MAAP case was created and run for each release category in Table 3-1 of the Level 2 report (e.g., MAAP run LERF-CI for case LERF-CI). Additional MAAP runs for LERF categories with more than one significant contributor were also performed to ensure the representative sequence was valid (e.g., LERF-CI, LERF-CF).

The categories were selected based on the types of sequences that Callaway produces. Failures or bypasses of containment lead to generally early releases.

Otherwise, a long time occurs until a later release due to containment overpressure or basemat melt through. Intermediate time sequences do not generally occur, and so no such category was needed.

e. Provide a discussion of the steps taken to insure the technical adequacy of the Level 2 PRA. Include, as part of your response, identification of peer reviews, gap analyses, or other reviews that were performed for the Level 2 PRA and when these reviews were performed.

Response

Several steps were taken to ensure the technical adequacy of the Level 2 PRA.

Within the technical staff of the contractor that performed the Level 2 PRA (ERIN Engineering & Research Inc.), an internal review was performed as evidenced by the signature sheet on the Level 2 PRA. Prior to finalization, the Level 2 PRA and report were also reviewed by Ameren/Callaway staff.

In addition, Appendix E of the Level 2 PRA report provides a self-assessment of the 2011 Level 2 PRA against the LE supporting requirements from the ASME PRA Standard. This roadmap identifies how the Level 2 PRA addresses the Category II LE supporting requirements. No gaps related to the Level 2 analysis were identified. The Level 2 roadmap is included as Enclosure 4 and provided with permission from ERIN Engineering and Research, Inc.

ULNRC-05908 September 24, 2012 Page 19 of 77

f. Table 3-6 gives the importance results for LERF and Table 3-7 gives the importance results for Late Release. Since there are five LERF release categories and two late release categories, please explain which release categories were included in these assessments, (i.e. all or just the largest contributor).

Response

The importance results for LERF and Late Releases use the general LERF and LATE release categories which combine the detailed LERF and LATE release categories. That is, LERF is the combination of the five LERF subcategories LERF-IS, LERF-CI, LERF-CF, LERF-SG, & LERF-ITR, while LATE is the combination of the two LATE subcategories LATE-BMT and LATE-COP.

3. Relative to External Events
a. Section F.3.1.2.2 states the following: "For the individual plant examination external events (IPEEE), Callaway used the Electric Power Research Institute (EPRI) seismic margins analysis (SMA) method. This analysis was transmitted to NRC in the IPEEE submittal. The latest estimate of the Callaway seismic contribution to CDF is 5.00E-6/yr."

A SMA does not normally include an estimate of seismic CDF. Please explain the source and basis for the 5.00E-6/yr value.

Response

The 5.00E-6/yr seismic CDF estimate was not developed directly from the IPEEE SMA. This estimate was derived using engineering insights from the IPEEE and more current studies (e.g. the NRC's Generic Issue 199 risk assessment report) for the sole purpose of developing the total external events multiplier used in the SAMA analysis.

There were no significant seismic vulnerabilities identified at the Review Level Earthquake acceleration analyzed by the IPEEE; thus the plant design was determined to be seismically robust. The Generic Issue 199 risk assessment calculated a seismic CDF of 2.3E-6 using the weakest link model for Callaway.

However, that risk assessment was a relatively generic assessment. To account for modeling uncertainties Engineering judgment was used and the calculated value was doubled and rounded up for use in developing the seismic contribution to the total external events multiplier.

b. Section F.3.1.2.3 states that the risk for tornado events is 2.5E-05/yr. and this is considered a contributor to the external events initiator group for calculating the external events multiplier.
i. Provide the basis for computation of this value. Include in this description consideration of buildings that are not tornado hardened and systems that could be failed by the tornado.

ULNRC-05908 September 24, 2012 Page 20 of 77

Response

Callaway does not have a high winds PRA and thus an engineering estimate of high winds CDF contribution was developed. This estimate was derived using engineering insights from the IPEEE and the internal events PRA for the sole purpose of developing the total external events multiplier used in the SAMA analysis.

The most relevant value for tornado frequency calculated in the FSAR Site Addendum, section 2.3.1.2.6.1, is 5E-4/yr. Due to the robust building design basis for tornado loading, described in FSAR section 3.3.2.1, it is virtually certain that no safety related equipment credited in the PRA would be damaged by any tornado. However, when combined with random failures of safety related equipment, it is still assumed that a tornado could contribute to CDF by impacting offsite power and other PRA credited equipment not protected by hardened structures. It is conservatively assumed that 50 percent of potential tornados would be of sufficient strength and size to cause wide spread damage to unprotected equipment. Assuming that a tornado disables the following unprotected equipment: normal and alternate sources of offsite power, non-safety related service water and the non-safety related auxiliary feedwater pump; the conditional core damage probability (CCDP) is on the order of 1E-3. If it is assumed that the ultimate heat sink (safety related water source) is also disabled, the CCDP could approach 1.0. Given that there is a range of CCDPs associated with different combinations of wind damaged equipment and varying combinations of random equipment failures, a CCDP of 0.1 was chosen as a representative value for the convolution of CCDPs from potential damage states. Thus, 5E-4/yr

  • 0.5
  • 0.1 results in a conservatively estimated 2.5E-5/yr CDF from tornados.

ii. Identify SAMAs to mitigate the contribution this makes to the total CDF.

Response

SAMA 15 is related to tornado impacts; however this contribution is included in the internal events loss of offsite power initiator and is not considered an external event. There are no other SAMA items directly related to tornado impacts. New SAMAs intended to protect the equipment referenced in the response above would be of such a scale that they would be physically infeasible from an engineering perspective and prohibitively expensive from a SAMA cost benefit perspective.

ULNRC-05908 September 24, 2012 Page 21 of 77

4. Relative to the Level 3 analysis
a. Tables F.3-9 and 3-10 provide the year 2044 population distribution used in the MELCOR Accident Consequence Code System, Version 2 (MACCS2) analysis.

Since the SECPOP2000 code was utilized to develop initial residential population estimates for each spatial element within the 50 mile region based on year 2000 census data, provide the year 2000 population distribution (Table 2.6-1 provides only a partial breakdown).

Response

The year 2000 population distribution is provided in Tables 4a-1 and 4a-2 below, in a format similar to that of Tables F.3-9 and F.3-10. This year 2000 population includes permanent residents (developed from the SECPOP2000 code) and population associated with transients and special populations for the 0-10 mile region (developed from the Callaway evacuation time estimate study). (See response to RAI 4c regarding the inclusion of special populations). The year 2000 population distribution provided in Tables 4a-1 and 4a-2 was used as the basis for the population projection to year 2044.

Table 4a-1 Year 2000 Population Distribution Within a 10-Mile Radius 0-1 1-2 2-3 3-4 4-5 5-10 10 mile Sector mile miles miles miles miles miles Total N 5 5 50 136 55 202 453 NNE 6 19 50 50 69 262 456 NE 6 5 0 16 29 52 108 ENE 6 7 0 0 0 95 108 E 6 5 0 0 77 109 197 ESE 16 5 2 11 34 140 208 SE 6 5 0 46 64 169 290 SSE 5 5 4 0 0 179 193 S 0 0 3 2 0 976 981 SSW 0 51 0 50 10 88 199 SW 0 0 0 0 74 1461 1535 WSW 0 0 0 0 28 548 576 W 0 131 0 0 0 583 714 WNW 0 56 84 83 102 852 1177 NW 0 0 1 15 5 789 810 NNW 0 0 26 24 7 455 512 Total 56 294 220 433 554 6960 8517

ULNRC-05908 September 24, 2012 Page 22 of 77 Table 4a-2 Year 2000 Population Distribution Within a 50-Mile Radius 0-10 10-20 20-30 30-40 40-50 50 mile Sector miles miles miles miles miles Total N 453 803 6498 1356 1901 11011 NNE 456 564 2533 2036 5610 11199 NE 108 861 3790 1333 2285 8377 ENE 108 524 3120 3608 17555 24915 E 197 1517 1154 12724 18022 33614 ESE 208 3148 2168 6700 34651 46875 SE 290 769 1352 5248 7069 14728 SSE 193 420 928 6785 4519 12845 S 981 1934 1624 3297 2592 10428 SSW 199 2291 2794 1996 2664 9944 SW 1535 1468 14347 4912 3642 25904 WSW 576 6035 43896 12195 7166 69868 W 714 2481 5767 2454 3572 14988 WNW 1177 5989 15341 95759 3525 121791 NW 810 9801 2338 8352 5217 26518 NNW 512 2400 8287 6253 1534 18986 Total 8517 41005 115937 175008 121524 461991

b. Section F.3.4.1 identifies that the population was projected to year 2044 using county growth estimates. Please describe how the county growth rates were applied (e.g., county weighted per sector, or State average uniformly applied across all sectors). In addition, if sectors or counties were projected to have negative growth, describe how they were treated.

Response

To obtain the year 2044 population projection, individual county growth rates were applied at the polar coordinate grid element level such that adjacent grid elements may use different growth rates if different county data applies.

Some grid elements include land from multiple counties. In such cases, a weighted growth rate was developed for those grid elements based on the fraction of land in that grid element associated with each county.

The county growth rates were developed based on Missouri Office of Administration (MOA) projected population data. MOA provides projected population data for each county in 5 year increments, from year 2000 to 2030.

County growth rates were calculated using the MOA population data from year 2000 (census data) and year 2025 (MOA projection), not year 2030 as implied in Section F.3.4.1. The year 2025 was chosen in lieu of 2030 based upon the year 2025 being closer to the mid-point of the total required projection period (from year 2000 to 2044). Originally, consideration was given to projecting the population out to year 2050, and use of the 2000-2025 period would allow applying the same growth factor for each grid element successively to project to 2050. Projection to year 2050 was subsequently

ULNRC-05908 September 24, 2012 Page 23 of 77 judged to be overly conservative, and year 2044 (end of license) was selected for use. The MOA-based county growth rates were applied, as applicable, to each grid element as discussed above, to calculate a year 2025 projected population distribution. This process was then repeated to project from year 2025 to year 2044, using the year 2000-2025 growth factors with an adjustment factor of 0.76 applied (i.e., 19yr/25yr) to represent the shorter projection period associated with years 2025 to 2044.

Two counties were projected to have negative growth in the year 2000 to 2025 time period, Howard and Montgomery. Zero growth (rather than negative growth) was conservatively assumed for these two counties for the Callaway population projection.

It is noted that projecting the population to year 2044 (the last year of the Callaway license renewal term) rather than a year within the second half of the period of extended operation (NEI 05-01, Section 3.4.1), which could be as early as 2034, provides conservatism.

c. Section F.3.4.1 identifies that transient population data was included within the 10-mile radius. Provide the year 2000 transient population and identify whether the transient population was scaled to the year 2044. Briefly discuss how the year 2000 transient population was included within the 10-mile radius. If transient population was not addressed, provide the impact of accounting for transient population on the SAMA evaluation.

Response

Transient population data was included in the 10-mile radius prior to the population projection such that transient population data was scaled to year 2044 using grid element growth factors developed for the permanent resident population data. The transient population data was obtained from Figure 6a of the Callaway evacuation time estimate (ETE) study. It is noted that the ETE also identified special facility population data associated with individuals in institutions such as hospitals, nursing homes, schools, and jails.

This special facility population data could include individuals (e.g., hospital patients) not included in census based residential population data. Therefore, this special facility data (from ETE Figure 7a) was included with the identified transient population data prior to the population projection such that special facility data was also scaled to year 2044 using grid element growth factors developed for the permanent resident population data. Inclusion of special facility data may result in some conservatism because some special facility populations such as nursing homes and jails may be included in permanent resident data.

The ETE transient and special facility population data (Figures 6a and 7a, respectively) are provided for each of the 16 sector directions for radial intervals of 0-to-2 miles, 2-to-5 miles, and 5-to-10 miles. For the 0-to-2 miles and 2-to-5 miles intervals, the population was divided evenly between the grid elements used in the MACCS2 analysis. If the population could not be divided evenly, the additional population was added to the grid element(s) closest to the site.

ULNRC-05908 September 24, 2012 Page 24 of 77 Table 4c-1 provides the year 2000 transient (including special facility) population distribution. The special facility population is specifically provided per the table notes.

Table 4c-1 Year 2000 Transient (Including Special Facility) Population Distribution Within a 10-Mile Radius 0-1 1-2 2-3 3-4 4-5 5-10 10 mile Sector mile miles miles miles miles miles Total N 5 5 50 50 50 0 160 NNE 6 5 50 50 50 0 161 NE 6 5 0 0 0 0 11 ENE 6 5 0 0 0 0 11 E 6 5 0 0 0 0 11 ESE 5 5 0 0 0 42 52 SE 6 5 0 0 0 42 53 SSE 5 5 0 0 0 42 52 S 0 0 0 0 0 345(1) 345 SSW 0 0 0 0 0 58 58 SW 0 0 0 0 0 1155(2) 1155 WSW 0 0 0 0 0 0 0 W 0 0 0 0 0 0 0 WNW 0 0 84 83 83 0 250 NW 0 0 0 0 0 0 0 NNW 0 0 0 0 0 0 0 Total 45 40 184 183 183 1684 2319 Notes:

(1) Includes special facility population of 287 persons.

(2) Includes special facility population of 1097 persons.

d. Section F.3.4.2 identifies that some generic economic data was used from NUREG-1150, and scaled using the consumer price index (CPI) to May 2010.

Please provide the effective cost escalation factor applied.

Response

An effective cost escalation factor of 2.0 was applied to escalate generic economic data used from NUREG-1150 (estimated to date from 1986) to May 2010. The cost escalation factor was derived from the CPI, as follows:

1986 Annual CPI = 109.6 May 2010 CPI = 218.178 Cost escalation factor = 218.178 / 109.6 = 1.991, rounded up to 2.0

e. Three sector population and economic estimator (SECPOP) 2000 code errors have been publicized, specifically: (1) incorrect column formatting of the output file, (2) incorrect 1997 economic database file end character resulting in the selection of data from wrong counties, and (3) gaps in the 1997

ULNRC-05908 September 24, 2012 Page 25 of 77 economic database numbering scheme resulting in the selection of data from wrong counties. Address whether these errors were corrected in the Callaway analysis. If they were not corrected, then provide a revised cost-benefit evaluation of each SAMA with the errors corrected.

Response

All three SECPOP2000 code errors were accounted for in the original submittal such that the errors did not impact the Callaway analysis. Error #1 (incorrect column formatting of the SECPOP2000 output file which can lead to incorrect column formatting of the SITE input file) was accounted for by ensuring that the column alignment of the final SITE input file was correct (e.g., manually adjusting the column formatting as needed). Errors #2 and #3 both involve the 1997 economic database associated with SECPOP2000.

Section F.3.4.2 notes that the 1997 economic database was not used because of the age of the data. Instead, more recent data (e.g., 2007 Census of Agriculture, 2008 Bureau of Economic Analysis, 2010 Bureau of Labor Statistics) was obtained and the calculation approach documented in NUREG/CR-6525 (SECP2000) was used to develop regional economic data inputs. This was done in an electronic spreadsheet rather than using SECPOP2000. Because the 1997 economic database associated with SECPOP2000 was not used, the associated errors (#2 and #3) were avoided.

f. The emergency response sensitivity shows a +7 percent change for slower evacuation and a +2.4 percent change for delayed evacuation. Is the higher impact for evacuation speed due to unsheltered travel and/or exposure to "higher" initial dose releases versus early sheltering and lower delayed releases?

Response

Sensitivity to emergency response inputs (i.e., delay time to evacuation, evacuation speed) was evaluated by means of sensitivity analysis. Section 3.4.4 summarizes that the first sensitivity case evaluated the impact of increased delay time before evacuation begins (i.e., vehicles begin moving in the 10-mile region). For this sensitivity case, the base delay time of 105 minutes was doubled to 210 minutes. The second sensitivity case evaluated the impact of a reduced evacuation speed. For this second sensitivity case, the evacuation speed was halved from 2.14 m/s (4.8 mph) to 1.07 m/s (2.4 mph). Section 3.4.4. specifies that the increased delay time case and the decreased evacuation speed case shows a dose increase of about 2.4% and 7%, respectively. Review of these dose impact values indicates that they are incorrect. The 2.4% and 7% reported values were based on release frequencies that were subsequently updated, but the text of Section 3.4.4 was not updated appropriately.

Additionally, while reviewing the Callaway MACCS2 modeling to respond to the RAIs, an error was found involving the evacuation zone distance. The MACCS2 model used to develop the results for the Attachment F SAMA analysis incorrectly modeled evacuation of individuals within 20 miles of the Callaway plant rather than within 10 miles, as intended. The model was corrected and a MACCS2 sensitivity case was run to determine the impact of

ULNRC-05908 September 24, 2012 Page 26 of 77 the error on the base case analysis. The impact was found to be very small.

The population dose risk increased from 4.60 person-rem/yr to 4.65 person-rem/yr (an approximately 1% increase). The cost risk did not change. To provide a perspective on this change, the impact on the SAMA analysis is less than the change associated with using a different year of weather data.

Table 4f-1 provides the results of the sensitivity case with the corrected evacuation modeling for comparison to Table 3-14 (which was based on evacuation of individuals within 20 miles). The ingestion dose results (Table 3-15) are not impacted by this evacuation correction because ingestion dose is accumulated over the long term.

Table 4f-1 Base Case Evacuation Region Corrected Dose and Cost Results (0-50 Mile Radius from Callaway Site)

Release Frequency Dose Dose Risk Cost Cost Risk Category (per yr) (p-rem) (p-rem/yr) ($) ($/yr)

LERF-IS 1.73E-07 1.91E+06 3.30E-01 8.22E+09 1.42E+03 LERF-CI 1.66E-10 7.81E+05 1.30E-04 4.80E+09 7.97E-01 LERF-CF 1.13E-08 8.44E+05 9.54E-03 5.49E+09 6.20E+01 LERF-SG 2.33E-06 9.35E+05 2.18E+00 4.92E+09 1.15E+04 LERF-ITR 2.17E-07 1.22E+06 2.65E-01 8.01E+09 1.74E+03 LATE-BMT 2.55E-06 3.92E+04 1.00E-01 4.91E+07 1.25E+02 LATE-COP 3.19E-06 5.45E+05 1.74E+00 1.86E+09 5.93E+03 INTACT 8.08E-06 2.87E+03 2.32E-02 1.25E+06 1.01E+01 Total 1.66E-05 -- 4.65E+00 -- 2.08E+04 When the distance within which people were evacuated was corrected from 20 miles to 10 miles, the impact on different release categories varied. For most release categories, the population dose increased as would generally be expected because fewer people were evacuating (i.e., those in the 10-to-20 mile region were no longer evacuating.) Those individuals who were no longer evacuating would generally be expected to receive additional dose. For two release categories (i.e., LERF-IS and LERF-ITR) the dose decreased slightly. Review of the release timing for these two release categories indicates that people in the 10-to-20 mile region were just beginning their evacuation movement at approximately the time the first release plume was entering the 10-to-20 mile region. (The average wind speed in the 2008 meteorological data is approximately 7.3 mph, which roughly corresponds to a time of 1.4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> before the plume reaches 10 miles. Wind speeds associated with specific weather sequences used in a MACCS2 run will vary.)

People who are evacuating are modeled to have less shielding than those who are not evacuating. Therefore, by eliminating the evacuation in the 10-to-20 mile region, these individuals received less dose for these releases. The cost impacts associated with correcting the evacuation region distance was negligible.

The sensitivity cases for the evacuation delay time (i.e., 210 minutes) and slower evacuation speed (i.e., 1.07 m/s (2.4 mph)) were repeated using the corrected evacuation zone distance. The dose results are presented in Table

ULNRC-05908 September 24, 2012 Page 27 of 77 4f-2 for evacuation delay and Table 4f-3 for evacuation speed. The dose results of Tables 4f-2 and 4f-3 may be compared to those of Table 4f-1.

Table 4f-2 demonstrates that increasing the delay time from 105 minutes to 210 minutes increases the dose risk by approximately 2.7% (compared to the corrected base case analysis). Table 4f-3 demonstrates that decreasing the evacuation speed from 1.14 m/s to 1.07 m/s increases the dose risk by approximately 6% (compared to the corrected base case analysis).

Per Table 4f-2, the increased delay time results in decreased dose for two release categories (i.e., LERF-IS and LERF-ITR). Both of these releases involve short duration initial plumes (i.e., less than 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />) with relatively high release fractions (i.e., > 0.1 CsI) that occur relatively rapidly compared to the time of GE declaration. As a result, the increased delay time affords individuals increased shielding (e.g., at their residences) while the first plume passes over before their evacuation movement begins (when less shielding is provided by their vehicles). In comparison, the slower evacuation movement case (Table 4f-3 results) does not afford this additional shielding effect, and therefore, a slower evacuation speed has a larger impact (for the parameter values utilized).

Table 4f-2 Increased Delay Time Sensitivity (Evacuation Region Corrected) Dose Results (0-50 Mile Radius from Callaway Site)

Release Frequency Dose Dose Risk Dose Risk Category (per yr) (p-rem) (p-rem/yr) Change from Base Case

(%)

LERF-IS 1.73E-07 1.77E+06 3.06E-01 -7.3%

LERF-CI 1.66E-10 7.92E+05 1.31E-04 1.4%

LERF-CF 1.13E-08 8.53E+05 9.64E-03 1.1%

LERF-SG 2.33E-06 1.00E+06 2.33E+00 7.0%

LERF-ITR 2.17E-07 1.19E+06 2.58E-01 -2.5%

LATE-BMT 2.55E-06 3.92E+04 1.00E-01 0.0%

LATE-COP 3.19E-06 5.46E+05 1.74E+00 0.2%

INTACT 8.08E-06 2.87E+03 2.32E-02 0.0%

Total 1.66E-05 -- 4.77E+00 2.7%

ULNRC-05908 September 24, 2012 Page 28 of 77 Table 4f-3 Decreased Evacuation Speed Sensitivity (Evacuation Region Corrected) Dose Results (0-50 Mile Radius from Callaway Site)

Release Frequency Dose Dose Risk Dose Risk Category (per yr) (p-rem) (p-rem/yr) Change from Base Case

(%)

LERF-IS 1.73E-07 2.01E+06 3.48E-01 5.2%

LERF-CI 1.66E-10 7.95E+05 1.32E-04 1.8%

LERF-CF 1.13E-08 8.52E+05 9.63E-03 0.9%

LERF-SG 2.33E-06 1.04E+06 2.42E+00 11.2%

LERF-ITR 2.17E-07 1.29E+06 2.80E-01 5.7%

LATE-BMT 2.55E-06 3.92E+04 1.00E-01 0.0%

LATE-COP 3.19E-06 5.46E+05 1.74E+00 0.2%

INTACT 8.08E-06 2.88E+03 2.33E-02 0.3%

Total 1.66E-05 -- 4.93E+00 6.0%

g. Provide the MAAP and MACCS2 (if different than MAAP) radioisotope grouping and identify the release time for early versus late release.

Response

MAAP 4.0.7 (used for Callaway) uses 12 radioisotope groups as follows:

Group # Description 1 Noble (Xe, Kr) and Inert aerosols 2 CsI, RbI 3 TeO2 4 SrO 5 MoO2, RuO2, TcO2 6 CsOH, RbOH 7 BaO 8 La2O3, Pr2O3, Nd2O3, Sm2O3, Y2O3, ZrO2, NbO2 9 CeO2, NpO2, PuO2 10 Sb 11 Te2 12 UO2

ULNRC-05908 September 24, 2012 Page 29 of 77 MACCS2 uses nine radioisotope groups as follows:

Group # Description 1 Xe, Kr 2 I 3 Cs, Rb 4 Te, Sb 5 Sr 6 Ru, Co, Mo, Tc, Rh 7 La, Y, Zr, Nb, Pr, Nd, Am, Cm, 8 Ce, Np, Pu 9 Ba The 12 MAAP groups were mapped to the nine MACCS2 groups as follows:

MACC2 Group # MAAP Group #

1 1 2 2 3 6 4 3, 10, 11 5 4 6 5 7 8 8 9, 12 9 7 For cases where multiple MAAP groups were assigned to a MACCS2 group, the largest release fraction of the MAAP groups was used for the MACCS2 group.

In the Callaway Level 2 PRA, the distinction between early and late releases includes consideration of the associated plant specific source term such that the distinction is between LERF and non-LERF. In general releases that occur within a few hours of a declaration of a general emergency (GE) and have a CsI cumulative release fraction approaching or above 0.1 are defined as LERF. Releases that have a lower CsI release fraction or tend to occur later, such as due to containment overpressure or basemat meltthrough, are defined as non-LERF releases. In the Callaway release category naming scheme, these non-LERF releases are identified as LATE- because they have a significant delay prior to significant release.

Attachment F Table 3-13 identifies the time of GE declaration and the times of release of individual plumes for each release category used in the MACCS2 analysis, based on the MAAP plant specific analysis. As a result, the MACCS2 modeling is not dependent upon a specific definition of early versus late releases.

h. Identify the specific reference for the Callaway Evacuation Study. In your response, please discuss whether and how the evacuation time was adjusted for the difference in population between year 2045 and the year of

ULNRC-05908 September 24, 2012 Page 30 of 77 the referenced evacuation time estimate study. If the evacuation time was not adjusted for the difference in population between year 2045 and the year of the referenced evacuation time estimate study, briefly discuss the potential impact to the SAMA evaluation. Identify whether the emergency planning zone (EPZ) was treated as a single evacuation zone.

Response

The specific reference for the Callaway Evacuation Study is as follows:

Evacuation Time Estimate for the Callaway Nuclear Plant Emergency Planning Zone, July 2002, Appendix G of Radiological Emergency Response Plan (RERP) Revision 36.

No adjustment was made to the estimated evacuation time to account for potential differences between the year 2044 population (the year of the population projection for the SAMA analysis) and the year of the time estimate study (2002) for the MACCS2 basecase analysis. It is generally assumed that increases in population will be accompanied by increases in infrastructure (e.g., road widening) during this lengthy time period such that the evacuation speed will not significantly decrease. The base case evacuation speed assumed for the analysis is 2.14 m/s (4.8 mph).

Sensitivity to evacuation speed was evaluated by means of sensitivity analysis, as discussed in response to RAI 4f. The results of Table 4f-3 may be compared to those of Table 4f-1 and demonstrate that reducing the evacuation speed by one half results in an increase of the population dose risk from 4.65 p-rem/yr to 4.93 p-rem/yr, an increase of approximately 6%.

This dose increase is relatively modest and demonstrates that a relatively significant decrease in the evacuation speed will not have a significant impact on the SAMA dose risk.

Table 4h-2 Slower Evacuation and Evacuation Region Corrected Dose and Cost Results (0-50 Mile Radius from Callaway Site)

Release Frequency Dose Dose Risk Cost Cost Risk Category (per yr) (p-rem) (p-rem/yr) ($) ($/yr)

LERF-IS 1.73E-07 2.01E+06 3.48E-01 8.22E+09 1.42E+03 LERF-CI 1.66E-10 7.95E+05 1.32E-04 4.80E+09 7.97E-01 LERF-CF 1.13E-08 8.52E+05 9.63E-03 5.49E+09 6.20E+01 LERF-SG 2.33E-06 1.04E+06 2.42E+00 4.92E+09 1.15E+04 LERF-ITR 2.17E-07 1.29E+06 2.80E-01 8.01E+09 1.74E+03 LATE-BMT 2.55E-06 3.92E+04 1.00E-01 4.91E+07 1.25E+02 LATE-COP 3.19E-06 5.46E+05 1.74E+00 1.86E+09 5.93E+03 INTACT 8.08E-06 2.88E+03 2.33E-02 1.25E+06 1.01E+01 Total 1.66E-05 -- 4.93E+00 -- 2.08E+04 For evacuation, 95% of the population is assumed to evacuate the 10 mile radius portion of the EPZ, radially away from the site. This 95% evacuation is modeled as a single evacuation zone. Five percent of the population is assumed to not participate in the evacuation.

ULNRC-05908 September 24, 2012 Page 31 of 77

i. Section F.3.4.5 indicates that the year 2008 meteorological data was more conservative than years 2007 and 2009. Describe the basis for this assertion and briefly quantify the relative conservatism. In addition, please identify the meteorological tower heights (i.e. potential range of measurement elevations) for the onsite meteorology station and for the station at the Prairie Fork Conservation.

Response

[Note: In the ERIN MACCS2 report, Table 4.2-1 provides the results of the meteorological sensitivities (see cases CALMET07, CALMET09). For these cases the change in population dose risk and cost risk ranged from -4% to 0%. These results formed the basis for the characterization of year 2008 met data providing conservative results. Following finalization of the ERIN report, the Level 2 release category frequencies were apparently updated (i.e., the frequencies in Table F.3-14 are different than in ERIN Report Table 4.2-1).

The changes in the release frequencies result in year 2008 data being less conservative, and non-conservative for cost risk for 2007. The RAI response addresses the 2007 data using different justification however.]

Table 4i-1 provides the frequency-weighted 50-mile population dose risk and cost risk results for each of the years of weather data evaluated, calculated using the MACCS2 model used for the results documented in Attachment F.

Table 4i-1 Attachment F Callaway Meteorological Sensitivity Results 50-mile Pop Dose 50-mile Risk Delta from Cost Risk Delta from Met Data Year (p-rem/yr) 2008 Basecase ($/yr) 2008 Basecase 2008 4.60 -- 2.08E+04 --

(base case) 2007 4.58 -0.4% 2.09E+04 0.5%

2009 4.60 0% 2.02E+04 -2.9%

For the 2009 sensitivity case, the 50-mile population dose risk and cost risk exhibit no change (dose risk) or a slight decrease (cost risk). For the 2007 sensitivity case, the dose risk showed a slight decrease while the cost risk showed a slight increase.

RAI response 4f identifies an error discovered in the MACCS2 evacuation modeling that results in small changes to the risk metrics. When the evacuation modeling is corrected, the results of the meteorological sensitivities cases are as shown in Table 4i-2.

ULNRC-05908 September 24, 2012 Page 32 of 77 Table 4i-2 Callaway Meteorological Sensitivity Results for Corrected Evacuation 50-mile Pop Dose 50-mile Risk Delta from Cost Risk Delta from Met Data Year (p-rem/yr) 2008 Basecase ($/yr) 2008 Basecase 2008 4.65 -- 2.08E+04 --

(base case) 2007 4.61 -0.9% 2.09E+04 0.5%

2009 4.62 -0.6% 2.02E+04 -2.9%

Use of the year 2008 meteorological data is slightly conservative in terms of dose risk and cost risk compared to year 2009 meteorological data. For year 2007, the dose risk is conservative but the cost risk is slightly non-conservative. For reasons discussed below, year 2008 data were preferred over year 2007 data.

In addition to Callaway on-site meteorological data, additional weather data was obtained from nearby Prairie Fork Conservation Station due to incomplete Callaway on-site precipitation data. Use of data from the Prairie Fork Conservation Station was limited to precipitation data only (i.e., not wind speed or wind direction) for portions of year 2007 only (i.e., the 2008 and 2009 meteorological data sets used in the MACCS2 analysis did not incorporate any data from the Prairie Fork Conservation Station). Use of precipitation data from Prairie Fork Conservation Station was warranted for 2007 due to significant precipitation data voids (approximately 23% for year 2007) associated with Callaway on-site precipitation gage malfunctions and system upgrades. The inclusion of off-site precipitation data for year 2007 to fill significant data voids was a determining factor in not selecting the 2007 meteorological data set for the base case MACCS2 analysis.

The Callaway on-site meteorological data is collected at heights of 10m, 60m and 90m. The Prairie Fork Conservation Station precipitation data is collected near ground level (at approximately 0.8m)

j. Provide the values and associated assumptions made about the following MACCS2 input parameters: rainfall, mixing heights, building wake effects, plume release energy, land fraction, region index, watershed index, growing season, fraction of farmland, and shielding and protection factors.

Response

Rainfall Site specific precipitation data was used for the Callaway MACCS2 analysis.

Site specific precipitation data for year 2007 was supplemented by data from the Prairie Fork Conservation Station. (See response to RAI 4i for further discussion on the use of Prairie Fork Conservation Station precipitation data).

The total (i.e., annual) precipitation included in each MACCS2 meteorological file is as follows:

ULNRC-05908 September 24, 2012 Page 33 of 77 Year Total Precipitation 2007 27.7 inches 2008 (base case) 53.1 inches 2009 60.3 inches Mixing Heights The atmospheric mixing height values included in the MACCS2 meteorological input files were based on Holzworth (Mixing Heights, Wind Speeds, and Potential for Urban Air Pollution Throughout the Contiguous United States, EPA, January 1972). This is a copyrighted reference and is therefore not supplied with this response. The following mixing height values were used in the Callaway MACCS2 analysis:

Time Winter Spring Summer Autumn Morning 460m 500m 350m 350m Afternoon 890m 1600m 1690m 1400m Building Wake Effects In MACCS2 the initial size of the plume is influenced by the building wake which is dependent on the width (W) and height (H) of the building. For the Callaway MACCS2 analysis, values for the initial plume standard deviation parameters sigma-y (SIGYINIT) and sigma-z (SIGXINIT) were calculated using plant specific containment dimensions and the following relationships documented in the MACCS2 Users Guide:

Sigma-y = W / 4.3 Sigma-z = H / 2.15 The Callaway containment width is approximately 45.3 m, and the containment height is approximately 63.6 m above grade level (from Callaway drawing M-2G029). Therefore, the initial plume parameters used are as follows:

Sigma-y = 45.3 m / 4.3 = 10.5 m Sigma-z = 63.6 m / 2.15 = 29.6 m These values were assumed for each of the plume segments associated with each release category.

The building height (MACCS2 parameter WEBUILDH) was a straight input of the Containment Buildings height of 63.6m.

Plume Release Energy For the base case MACCS2 analysis zero plume energy was assumed. A sensitivity case was performed to examine the impact of plume heat content. The sensitivity case assumed 1E+07 watts for each plume of each release, except for the intact containment case in which the assumption of zero plume heat was maintained. When plume heat content is included, the dose risk decreases approximately 2.1% and the cost risk increases approximately 1.7%. This sensitivity case demonstrates that the

ULNRC-05908 September 24, 2012 Page 34 of 77 assumption related to plume release energy has a very small impact on the MACCS2 results. (These results are based on using the corrected evacuation region MACCS2 model discussed in response to RAI 4f.)

Land Fraction The fraction of each spatial element that is land (as opposed to water) was visually estimated using maps and images of the 50-mile region. Table 4j-1 shows the land fractions used in the MACCS2 model.

Table 4j-1 Callaway Spatial Element Land Fractions Sector 0-1 1-2 2-3 3-4 4-5 5-10 10-20 20-30 30-40 40-50 N 0.95 0.99 0.96 0.95 0.95 0.99 0.99 0.98 0.98 0.95 NNE 0.95 0.99 0.98 0.99 0.94 0.99 0.99 0.99 0.98 0.99 NE 0.90 0.99 0.99 0.99 0.96 0.99 0.99 0.99 0.98 0.98 ENE 0.97 0.99 0.99 0.98 0.99 0.99 0.98 0.98 0.98 0.98 E 0.99 0.99 0.99 0.97 0.98 0.99 0.98 0.97 0.98 0.98 ESE 0.99 0.99 0.99 0.99 0.99 0.95 0.95 0.97 0.95 0.95 SE 0.98 0.99 0.99 0.99 0.90 0.95 0.98 0.98 0.99 0.98 SSE 0.95 0.99 0.99 0.99 0.80 0.98 0.98 0.98 0.98 0.98 S 0.97 0.99 0.99 0.99 0.98 0.96 0.99 0.97 0.97 0.97 SSW 0.97 0.99 0.99 0.99 0.98 0.95 0.98 0.97 0.99 0.98 SW 0.97 0.99 0.99 0.97 0.96 0.98 0.96 0.94 0.97 0.97 W 0.98 0.99 0.99 0.96 0.99 0.99 0.99 0.95 0.98 0.98 WNW 0.97 0.99 0.99 0.96 0.99 0.99 0.99 0.99 0.96 0.98 NW 0.99 0.99 0.99 0.98 0.97 0.99 0.99 0.99 0.98 0.97 NNW 0.98 0.99 0.97 0.97 0.98 0.99 0.99 0.99 0.99 0.99 N 0.98 0.99 0.97 0.95 0.96 0.99 0.99 0.99 0.99 0.98 Region Index A total of 63 regions are defined for the MACCS2 model for the 50-mile region surrounding the Callaway plant. Spatial elements of the 50-mile polar coordinate grid within the same county have the same

ULNRC-05908 September 24, 2012 Page 35 of 77 index value. Spatial elements involving multiple counties have unique index values.

Watershed Index All spatial elements within the 50-mile region surrounding the Callaway plant are designated as river systems. Per NUREG/CR-4551 the designation of lake is only used for very large bodies of water, such as Lake Michigan, which may serve as drinking water sources. The lakes around the Callaway site are smaller and are expected to behave like river systems.

Growing Season Growing season and crop share data are required to be included in the MACCS2 SITE input file. Table 4j-2 provides the growing season and crop share data included in Callaway SITE file. These data are consistent with the values in the MACCS2 Users Guide. These data, however, are only implemented in MACCS2 when the old MACCS2 food model is used. For Callaway, the new COMIDA2 food model was used. Therefore, these growing season values have no impact on the Callaway MACCS2 results.

Table 4j-2 Callaway Crop Growing Season Inputs Calendar Growth Calendar Growth Crop Crop Start End Share Pasture 90 270 0.41 Stored Forage 150 240 0.13 Grains 150 240 0.21 Green Leafy 150 240 0.002 Vegetables Other Food Crops 150 240 0.004 Legumes and 150 240 0.15 Sees Roots and Tubers 150 240 0.003

ULNRC-05908 September 24, 2012 Enclosure 1 Page 36 of 77 Fraction of Farmland The fraction of farmland in each spatial element was estimated using county farm fraction data obtained from the 2007 Census of Agriculture, multiplied by the percentage of county in each spatial element (i.e., a land area weighting was applied to the county data). Table 4j-3 shows the farmland fractions used in the Callaway MACCS2 model corresponding to the region index.

Table 4j-3 Callaway MACCS2 Region Farm Fraction Input Region # Description Farm Fraction Region # Description Farm Fraction 1 EXCLUSION 0.61 33 SE-40 0.50 2 CALLAWAY 0.61 34 OSAGE 0.77 3 N-20 0.91 35 SSE-10 0.72 4 N-30 0.96 36 SSE-20 0.67 5 N-40 0.75 37 SSE-30 0.64 6 NNE-10 0.64 38 SSE-40 0.48 7 NNE-20 0.79 39 S-30 0.72 8 NNE-30 0.93 40 S-40 0.69 9 NNE-40 0.86 41 SSW-05 0.73 10 NE-5 0.63 42 SSW-30 0.74 11 NE-10 0.71 43 SSW-40 0.70 12 MONTGOM 0.72 44 SW-5 0.64 13 NE-30 0.75 45 SW-10 0.67 14 NE-40 0.76 46 SW-20 0.74 15 ENE-05 0.68 47 SW-30 0.72 16 ENE-20 0.69 48 SW-40 0.66 17 ENE-30 0.59 49 WSW-20 0.64 18 ENE-40 0.62 50 WSW-30 0.76

ULNRC-05908 September 24, 2012 Enclosure 1 Page 37 of 77 Region # Description Farm Fraction Region # Description Farm Fraction 19 E-05 0.69 51 WSW-40 0.85 20 E-10 0.69 52 W-20 0.59 21 E-20 0.53 53 W-30 0.76 22 WARREN 0.54 54 W-40 0.91 23 E-40 0.48 55 WNW-20 0.59 24 ESE-05 0.68 56 BOONE 0.59 25 ESE-10 0.67 57 WNW-40 0.78 26 ESE-20 0.56 58 NW-20 0.64 27 ESE-30 0.52 59 NW-30 0.61 28 ESE-40 0.50 60 NW-40 0.73 29 SE-05 0.73 61 NNW-20 0.84 30 SE-10 0.65 62 NNW-30 0.89 31 SE-20 0.62 63 NNW-40 0.83 32 SE-30 0.54 -- -- --

Shielding and Protection Factors Shielding and protection factors used in the Callaway MACCS2 model are presented in Table 4j-4. Shielding and protection factors are taken from NUREG-1150 (NUREG/CR-4551). Shelter values for cloud shine and ground shine are based on those used in NUREG-1150 for Sequoyah. Sequoyah values were chosen because they represent reasonable mid-range values (for the five sites evaluated in NUREG-1150) and because the Sequoyah site is one of the closest NUREG-1150 sites to Callaway, such that similar conditions are expected.

ULNRC-05908 September 24, 2012 Page 38 of 77 Table 4j-4 Callaway Shielding and Protection Factors Description Evacuees Normal Activity Shelter Cloud Shielding 1 0.75 0.65 Factor Ground Shielding 0.5 0.33 0.20 Factor Protection Factor for 1 0.41 0.33 Inhalation Skin Protection 1 0.41 0.33 Factor

k. Table 3-15 provides ingestion doses. Identify the model(s) and version used and the critical input parameters used to produce these results.

Response

Food ingestion is modeled using the COMIDA2 food ingestion model (provided with MACCS2), consistent with Sample Problem A (i.e., the Sample Problem A COMIDA2 binary output file, SAMP_A.bin, was used as input to the MACCS2 calculation).

Water ingestion data inputs (e.g., NUMWPI, NAMWPI, WSHFRI, WSHRTA, WINGF) included in the CHRONC file are consistent with Sample Problem A, based on NUREG/CR-4551 values.

Food ingestion dose limit data inputs are based on 1998 FDA Guidance (Accidental Radioactive Contamination of Human Food and Animal Feeds: Recommendations for State and Local Agencies) that superseded the 1982 FDA Guidance incorporated in Sample Problem A. The values used for Callaway are as follows:

Dose Limit Variable Effective Thyroid (Sv) (Sv)

DOSEMILK001 0.0025 0.025 DOSEOTHR001 0.0025 0.025 DOSELONG001 0.005 0.050 It is noted that the ingestion doses identified in Table 3-15 are not affected by the evacuation modeling change identified in the response to RAI 4f.

5. Relative to the selection and screening of Phase I SAMA candidates
a. Table F.5-1 shows that while 6 out of the 171 SAMA candidates identified are plant specific SAMAs identified from plant-specific risk insights, it appears that the fire PRA for the recently submitted NFPA 805 LAR was not used as a source to generate plant-specific risk insights. Table F.3-4 shows that the external event contribution to total CDF is greater (e.g., fire CDF is 2.0E-5/yr) than the internal events

ULNRC-05908 September 24, 2012 Page 39 of 77 contribution (i.e., internal CDF is 1.7E-5/yr). Provide identification and evaluation of SAMAs based on plant specific insights from the post-transition fire PRA. Include, as part of this identification, consideration of fire PRA importance analysis, the dominant risk fire areas and associated sequences, and the risk of modifications that Callaway has committed to. Also, describe how this information was used to identify SAMA candidates and evaluate any resulting SAMA candidates not already evaluated. When evaluating the impact of additional SAMAs consider whether the fire related SAMA can have additional benefit from non-fire contributors.

Response

The results of the NFPA 805 Fire PRA were not available at the time the SAMA analysis was performed and therefore could not be used to identify and evaluate any SAMA candidates. The following summarizes the requested information.

Fire Areas Contributing >1% of Fire CDF and/or Fire LERF The following table shows individual fire areas that contribute at least 1% of total Fire CDF or Fire LERF, excluding the Multi-compartment (MCA) fire risk. The cumulative MCA risk is below 2E-7/yr, which is 1% of the total fire risk.

Table 5-2: Risk Significant, Individual Fire Areas Fire CDF LERF Total CDF Total LERF Area (1/yr) (1/yr) Contribution Contribution TB-1 6.54E-06 1.36E-07 32.4% 34.3%

A-21 5.13E-06 6.12E-08 25.4% 15.4%

C-10 1.72E-06 3.85E-08 8.5% 9.7%

C-22 1.35E-06 2.58E-08 6.7% 6.5%

YD-1 1.03E-06 2.18E-08 5.1% 5.5%

C-9 9.31E-07 2.10E-08 4.6% 5.3%

C-27 7.83E-07 2.06E-08 3.9% 5.2%

C-21 5.10E-07 4.17E-08 2.5% 10.5%

A-29 2.63E-07 2.29E-10 1.3% 0.1%

ULNRC-05908 September 24, 2012 Page 40 of 77 Table 5-2: Risk Significant, Individual Fire Areas Fire CDF LERF Total CDF Total LERF Area (1/yr) (1/yr) Contribution Contribution A-17 2.50E-07 2.29E-09 1.2% 0.6%

RB-1 2.36E-07 1.93E-09 1.2% 0.5%

A-13 2.04E-07 1.78E-10 1.0% 0.0%

C-24 1.30E-07 6.15E-09 0.6% 1.5%

The top 8 fire areas accounting for 89% of CDF and 92.4% of LERF are summarized below. The fire frequency in each area is comprised of many individual fire scenarios. There are approximately 1,300 fire scenarios in the Callaway fire PRA. The top 16 individual fire scenarios are discussed after the area discussion. The top 16 individual fire scenarios account for 58% of CDF and 59% of LERF.

Risk Significant Fire Areas Fire Area TB-1 has the highest CDF because it is the largest fire area and has the highest fire ignition frequency of any fire area. These fires do not generally fail any safety related equipment. The principle fire related failures are Offsite power and the non-safety service water system. Although there are generally two safety related trains to support shutdown after a turbine building fire, the random failures of these systems can lead to core damage. The average CCDP of turbine building fires is 2.3E-4, which is indicative of the failure of two safety related cooling water systems.

Fire Area A-21 has the opposite risk characteristics of TB-1. There are only 5 ignition sources in this area, but one of the ignition sources has two risk significant fire scenarios contributing to Fire CDF. Note that fire suppression is not credited in A-21.

Fire Area C-10 is an electrical switchgear room. The risk significant fires in this room will fail Offsite power, and train related safety equipment. There are switchgear fires in this room which have a high relative initiating event frequency and are postulated to be damage intensive. Extensive fire modeling was performed in this area, especially for the main buss. Automatic suppression is credited to reduce the risk of fires where possible.

ULNRC-05908 September 24, 2012 Page 41 of 77 Fire Area C-22 is a cable spreading room, which has a limited total ignition frequency of transient fires only. Although frequency of fires is low (automatic fire suppression is also credited), when fires do occur they can cause significant damage due to the cable content of the area. The risk profile of this room is the same as C-10.

The Yard (YD-1) is a CDF contributor because it causes Loss of Offsite Power, which in turn causes loss of the non-safety service water system. A simplified fire modeling approach was used in the YARD in which ten sub-areas or analysis areas were analyzed as whole-area burnouts. As such, within each analysis area the assumed fire damage was conservative, which, along with a relatively high ignition frequency, causes moderate risk. The dominant fires involve the transformer fires.

Fire Area C-9 is an electrical switchgear room. The risk profile of this switchgear room is similar to C-10, but pertains to the opposite train.

Fire Area C-27 is the Main Control Room (MCR). Risk significant fires in the control room involve main control board fires which fail significant safety related equipment of both trains (as well as MCR evacuation).

Fire Area C-21 is a cable spreading room. The risk profile of this cable spreading room is similar to C-22, but pertains to the opposite train.

Fire Scenarios Contributing Top 95% of Fire CDF and LERF The quantification of individual areas report supporting the NFPA-805 submittal contains tables showing all quantified fire scenarios (including fire-modeled and whole-area burnup scenarios) that contribute to the Fire CDF and LERF.

Fire scenarios contributing > 1% of Fire CDF are described in detail below:

Scenario 1501-1A Notable failures include MDAFP "B" via suction valves spurious close (SC), CCW "B" via EGHV16/54 SC and EFHV52 SC, EDG "B" via EFHV60 spurious open (SO), and all 4 RCP seal injection valves (8351A/B/C/D) SC. The fire damage leaves the plant running on Train "A" with no seal injection available from the NCP.

Cutsets are dominated by spurious fire-induced failures of CCW "A", spurious closure of any one RCP seal injection valve (leading

ULNRC-05908 September 24, 2012 Page 42 of 77 to seal LOCA), and failure to initiate recirc after successful injection.

Scenario 1501-1 This scenario is dominated by an RCP seal LOCA of 176 gal per minute in one or more pumps with successful ECCS injection, but failures in the ECCS recirculation mode due to a) human errors, b) spurious opening of EGTV0030, or c) spurious closure of EFHV0052. The loss of seal cooling is caused by spurious closure of the BBHV8351 valves [fire damage] and spurious closure of the CCW thermal barrier cooling isolation valves due to false signal from EGFT0062. Charging pumps and CCW pump are available, but blockage in the seal injection line and the CCW thermal barrier line isolate seal cooling to all RCPs. After 13 minutes, a 176 gpm LOCA is postulated to occur in each pump.

Scenario YD-SXFR This scenario involves a large transformer fire in the YARD. It fails all offsite power from the main switchyard to PA01 and PA02.

Offsite power is available to NB01 and NB02 from the Alternate Emergency Power System (AEPS). The dominant pathway to core damage is a loss of RCP seal cooling and a failure to provide RCS makeup in response. AFW is available throughout the sequence.

Contributors to risk are failures of both trains of ESW. The non-safety service water is unavailable due to LOSP. Loss of all ESW causes loss of all ECCS, CCW and the charging pumps. Non-safety charging pump is unavailable due to LOOP. Loss of seal cooling leads to RCP seal LOCA, which cannot be mitigated.

Scenario 4501-2B This scenario involves a large turbine hydrogen fire with failure of suppression. Collateral damage in the turbine building fails all offsite power from the main switchyard to NB01, NB02, PA01 and PA02. Offsite power is available to NB01 and NB02 from AEPS.

The dominant pathway to core damage is through a loss of AFW due to a loss of condensate. Included in this fire is a spurious opening of ADLV0079BB and ADLV0079BA, which drains the CST to minimum tech spec level. After a period of time the CST is empty and non-fire related failures of ESW pumps and room coolers lead to a loss of AFW pump suction. Feed and bleed is similarly failed by the same ESW failures which failed ESW water to the AFW system.

ULNRC-05908 September 24, 2012 Page 43 of 77 Scenario C10-8s This scenario is started by a fire in a motor control center, which causes significant cable damage in C-10. Significant train related safety systems are lost by the fire. Offsite power to PA01 and PA02 are also failed by the fire. Opposite train safety systems are unaffected. Offsite power is available to NB01. Core damage is caused by random failures of Train A safety equipment.

Scenario C10-17 This scenario is started by a fire in an electrical panel, which causes significant cable damage in C-10. All Significant train related safety systems are lost by the fire. Offsite power to PA01 and PA02 are also failed by the fire. Opposite train safety systems are unaffected. Offsite power is available to NB01. Core damage is caused by random failures of Train A safety equipment.

Scenario C9-12 This scenario is started by a fire in an electrical panel, which causes significant cable damage in C-9. Significant train related safety systems are lost by the fire. Offsite power to PA01 and PA02 are also failed by the fire. Opposite train safety systems are unaffected. Offsite power is available to NB02. Core damage is caused by random failures of Train B safety equipment.

Scenario RL015/016e Main Control Board RL15/16 Fire with MCR Evacuation This scenario is a large fire in control board panels RL015 and RL016 in the main control room. Fire is suppressed before is extends beyond the panel RL015/016, but all equipment controlled from this panel is unavailable. Safe shutdown is provided by safety train B equipment from the Auxiliary Shutdown Panel. Offsite power is available to NB02 from AEPS through PB05 and NB0214.

Failure to provide safe shutdown from the ASP is attributed to human error and random failures of train B equipment.

Scenario 3801T3 This scenario represents a transient fire in a cable spreading room

[C-22], which causes limited damage, but creates some high frequency undesired events. Seal injection isolation valves from all four RCPs [BBHV8141 and BBHV8351] are damaged in this fire.

Loss of seal cooling is virtually guaranteed. Spurious opening of ADLV0079BA/BB causes CST drain down to the minimum tech

ULNRC-05908 September 24, 2012 Page 44 of 77 spec water level; ESW makeup is eventually required. Feed and bleed cooling is unavailable due to fire damage to the PORVs.

Scenario 4501-3 This scenario is a catastrophic turbine generator fire which fails all equipment and cables in the Turbine Building, including normal offsite power and offsite power from the AEPS. Automatic fire suppression fails. Random failures of NE01 and NE02 lead to station blackout with no potential credited recovery.

Scenario 3501T11 This scenario represents a transient fire in a cable spreading room

[C-21], which causes loss of offsite power to PA01 and PA02 and loss of significant train related safety equipment. AFW is available from PAL02 and PAL01B. Random failures of Train B ESW/CCW and charging system failure to provide seal cooling leads to RCP seal LOCA.

Scenario 3801T2 This scenario represents a transient fire in a cable spreading room

[C-22], which causes limited damage, but creates some high frequency undesired events. Seal injection isolation valves from all four RCP's [BBHV8141 and BBHV8351] are damaged in this fire.

Loss of seal cooling is virtually guaranteed. Spurious opening of ADLV0079BA/BB causes CST drain down to the minimum tech spec water level; ESW makeup is eventually required. Feed and bleed cooling is unavailable due to fire damage to the PORVs.

Scenario 4501-1B This scenario involves a large turbine lube oil system fire.

Collateral damage in the turbine building fails all offsite power from the main switchyard to NB01, NB02, PA01 and PA02. Offsite power is available to NB01 and NB02 from the AEPS. The dominant pathway to core damage is through a loss of AFW due to a loss of condensate. Included in this fire is a spurious opening of ADLV0079BB and ADLV0079AA, which drains the CST to minimum tech spec level. After some period of time the CST is empty and non-fire related failures of ESW pumps and room coolers lead to a loss of AFW pump suction. Feed and bleed is similarly failed by the same ESW failures which failed ESW water to the AFW system.

ULNRC-05908 September 24, 2012 Page 45 of 77 Scenario A29-WR The scenario is caused by a large fire in A-29. Fire modeling was not employed in this room. This scenario fails steam line pressure instrumentation on all steam lines causing spurious opening of SG-ASD's. Fire also fails auxiliary feedwater flow indication on several SG's. Failure of the operator to respond to the loss of instrumentation leads to loss of SG cooling and failure of feed and bleed.

Scenario 4203-0 This is a large floor area transient fire in zone 4203. The normal charging pump and the 3 non-essential service water pumps are failed by this fire. There is no fire induced failure of any safety related equipment or offsite power. Fire risk is driven by random and common cause failures of the essential service water system pumps.

Scenario A-13 WR This scenario represents large fire in A-13. Fire induced failures include atmospheric steam dumps in Steam generators A, B, D.

Fire risk is dominated by fire induced damage to the SG isolation system, with random failure of the intact AFW pumps and failure of feed and bleed cooling.

Plant Modifications related to NFPA 805 The following modifications were identified by the NFPA 805 project.

The NFPA 805 project did not consider any other modifications to be necessary.

Modification 07-0066 - the buried carbon steel ESW piping was replaced with high density polyethylene (HDPE) piping. During the piping replacement the cabling associated with DFTE0067A and 68A was relocated to restore the required 20 foot separation criteria. This modification is complete. This modification was not assigned a specific SAMA since it is already complete.

Modification 10-0032 - Installed a non-safety related AFW pump as diverse AFW backup supply to the safety related motor driven and turbine driven pumps. This modification is complete. This modification is related to SAMAs 68 and 78.

Modification 10-0038 - Install four non-safety related diesel generators (8MW) at the electric cooperative substation. Either the electrical

ULNRC-05908 September 24, 2012 Page 46 of 77 cooperative substation or the 4 non-safety diesel generators will be able to power either Safety Related bus in the event of a loss of AC power and failure of the Emergency Diesel Generators. This modification is complete. This modification is related to SAMAs 9 and 14.

Modification 05-3029 - Install lower amperage fuses for various 14 AWG control circuits in the MCR. The majority of the modification centers around the trip circuit fuses on NB, NG, PA, PB, and PG system breakers. This modification is not complete. This modification was added as SAMA 180.

Modification 07-0151 - Install redundant fuses and isolation switches for MCR evacuation procedure OTO-ZZ-00001. This modification is not complete. This modification was added as SAMA 181.

Modification 09-0025 - To protect against multiple spurious operation scenarios, cable runs will be changed to run a single wire in a protected metal jacket such that spurious valve opening due to a hot short affecting the valve control circuit is eliminated for the fire area.

This modification will be implemented in multiple fire areas. This modification is not complete. This modification was added as SAMA 182.

Modification 12-0009 - Quick response sprinkler heads in cable chases A-11, C-30, and C-31 will be modified to be in accordance with the applicable requirements of NFPA 13-1976 edition. This modification is not complete. This modification was added as SAMA 183.

b. Section F.3.1.2.3 states the internal events PRA does not include an internal flooding modeling. However, Section F.3.1.1.2 indicates that internal flooding was included in the IPE and in a PRA update as recently as 2004. Discuss the results of the latest applicable internal flooding analysis, the differences from the IPE analysis cited for the internal flooding frequency identified in Section F.3.1.2.3 and potential internal flooding SAMAs based on the latest most applicable internal event flooding analysis.

Response

The statements referred to in Section F.3.1.2.3 pertain to the fact that, through PRA Update 4B, i.e., the internal events PRA version used in the SAMA analysis, the Callaway internal flooding analysis was not developed into a PRA model that could generate cutsets and thus not integrated into the internal events PRA model. As a result, when the

ULNRC-05908 September 24, 2012 Page 47 of 77 internal events model was perturbed to evaluate SAMAs, the CDF results did not include a contribution from internal flooding; and the stand-alone flooding analysis format did not support any practical method for assessment of SAMAs. Thus, the external events multiplier, developed in Section F.3.1.2.4, includes the PRA Update 4B internal flood numerical CDF of 9.14E-6 per year.

The latest Callaway internal flooding analysis was performed as part of the PRA Update 5 scope of work. The purpose of updating the internal flooding analysis in PRA Update 5 was to move the analysis to Capability Category II of the PRA Standard. Changes made to the analysis method were not dramatic in nature, and included items such as use of a more-recent flood initiator frequency database, more-accurate treatment of non-watertight door flood retention capabilities, and better treatment of operator actions to terminate floods.

As noted in the tabular response to RAI question 1.d.ii, the PRA Update 5 internal flooding analysis CDF is 6.21E-6, or only about two-thirds of the PRA Update 4B internal flooding CDF. Given the approach used to incorporate the internal flooding contribution to CDF in the SAMA analysis, i.e., by inclusion of the internal flooding CDF in the external events multiplier, use of the Update 4B internal flooding CDF in the SAMA analysis is conservative.

SAMA 160 is the only plant specific internal flooding related SAMA.

The 1999 internal flooding analysis used as a basis for the SAMA identified only one flood that was below the screening value used.

After implementation of the internal flooding task force recommendations, this flood was considered an acceptable risk and no further actions were needed.

Although the Callaway Internal Flooding analysis was updated following the submittal of the License Renewal LAR, there were no significant changes in methodologies used to develop flood scenarios, thus the insights used to assess SAMAs should not be significantly impacted and the existing method for addressing internal flooding in the SAMA analysis remains conservative.

c. Section F.5.2 states that potential enhancements identified in the IPE were included in Table F.5-1. Only four of the five enhancements identified in IPE Section 6.2.1, "Plant Improvements to be Implemented," are included in Table F.5-1 and none of the five enhancements in Section 6.2.2, "Plant Improvements to be Considered," were included. Provide the status and an evaluation of:

ULNRC-05908 September 24, 2012 Page 48 of 77

i. The missing improvements from IPE Section 6.2.1, addition of procedural guidance and the required hardware to enable the operators to feed one or more steam generators with a diesel driven firewater pump; and, ii. The five improvements listed in IPE Section 6.2.2.

Response

The items have been added to the SAMA list as SAMAs 172, 173, 174, 175, 176, and 177 which are included in Attachment 1 to this enclosure. All items have been implemented and therefore screen as Intent Met in the Phase I analysis.

d. Note 1 to Table F.3-2 states, "The current plant procedures and training meet current industry standards. There are no additional specific procedure improvements that could be identified that would affect the result of the human error probability (HEP) calculations.

Therefore, no SAMA items were added to the plant specific list of SAMAs as a result of the human actions on the list of basic events with RRW greater than 1.005." This appears to imply that meeting current industry standards is sufficient to indicate that no additional SAMAs are needed.

i. Provide additional information to justify the conclusion stated as indicated above.

ii. Explain the process used to make the determination that there are no opportunities to improve procedures and training. Include in the explanation how human error probability factors were considered (e.g., cognition, resources, timing, and stress level).

iii. Discuss whether any of the risk significant operator action failures could be addressed by options other than training or procedures such as automated functions, testing, and maintenance to reduce failure or event rates, or enhanced documentation. Specifically discuss the potential for automating the function associated with basic event OP-XHE-FO-CCWRHX (OPERATOR FAILS TO INITIATE CCW FLOW TO THE RHR HXS) identified in Table 3-2.

Response

In order to perform a cost/benefit analysis of any change, the impact on the calculated Human Error Probability must be determined. Discussion with the HRA analysts indicate that based on the current structure and format of the existing procedures, any incremental improvements or changes made to training or procedures would not result in the ability to take additional credit in the HRA because in general full credit is already taken.

ULNRC-05908 September 24, 2012 Page 49 of 77 Improvements may be possible through re-ordering steps in the EOP network to improve timing, however, since Callaway uses the standardized EOP network significant changes in EOP structure would result in compliance issues with EOP configuration control.

The current standardized EOP structure is based on the deterministic safety analysis, not a PRA analysis, thus while there may be PRA improvements there are significant analysis and infrastructure changes that would have to be implemented Industry-wide to change the standardized structure. Any enhancements that could be made within the standardized structure have either already been made at Callaway or would not result in additional significant credit in the HEP determination.

With no significant change to the HEP, the benefit of making the change would be negligible.

The note was not intended to state that no opportunities for improvement exist, rather that there would be no calculated dollar value benefit from any improvements made. Plant personnel are always encouraged to use the corrective action process to identify potential improvements. In addition, the PRA group reviews and actively participates in changes made to Operating Procedures to evaluate impact on the PRA as well as suggest improvements.

In general, operator actions credited in the Level 1 PRA, are proceduralized in the EOP and OTO procedure network. The EOP/OTO procedures address both cognition and execution as follows:

  • Cognition - specifically they identify the primary cue (instrumentation or alarm needed to make the diagnosis)
  • Execution - specifically they identify the tasks needed to accomplish the required action)

The EOP/OTO procedures are highly trained on both in the classroom and to the extent possible in the simulator or through job performance measures. All EOPs are required to be trained on at least once every six years. In general, most EOPS are trained on several times a year in both the simulator and class room training. There is a six week training cycle and each crew will spend one week in simulator and/or class room training during each six week cycle. The trainers review the procedures regularly to identify areas where the training crews have encountered difficulty and update the procedures accordingly. EOP/OTO Writers manual APA-ZZ-00102 is the guidance document the procedure writers follow to ensure that the procedures are written to be consistent with industry standards.

ULNRC-05908 September 24, 2012 Page 50 of 77 As part of the HRA task the EOP and OTO procedures are reviewed to ensure that credited operator actions in the PRA are proceduralized in the same context as the EOPs/OTOs. The HRA task accounts for the following:

  • Procedure Context -Does the procedure match the modeled PRA scenario,
  • Procedure Structure - Response not obtained column format vs paragraphs of instructions,
  • Procedure Wording - Does the procedure wording have a double negative,
  • Distinction of important steps (boxed, bulleted, bolded, etc),
  • Time to reach the required procedure step.

If the HEP is dominated by a single failure mechanism such as an ambiguously worded statement or not enough time to reach the required procedure step, then these findings are passed back to the Callaway training department and procedure revisions are made within the limitations of standardized procedures, as applicable.

The Callaway training department maintains a listing of time critical deterministic and PRA risk significant actions in procedure APA-ZZ-00395. On a defined cycle, the deterministic operator actions are evaluated/validated in the simulator, including timing of events.

There is considerable overlap in the deterministic operator actions and the PRA risk significant actions and timing information from these validations is used to evaluate the assumptions in the HRA.

This training identifies procedure ambiguities associated with the procedure guidance for most actions credited in the PRA. These completions times are not requirements but are intended to be nominal average estimates that most crews can achieve. Following the completion of a major PRA update APA-ZZ-00395 is updated.

As part of PRA Update 5, all Level 1 post-initiator operator actions were reviewed and updated to align with the current EOP/OTO procedure revisions and training. As part of this update, all risk-significant scenarios were talked through with Callaway trainers and insights from recent simulator training were incorporated into the updated HRA.

The process followed for this HRA update was:

1. Identify - Each PRA scenario was reviewed in the context of the appropriate EOP to ensure that the as-operated plant is reflected in the HRA.
2. Define - As part of the definition a feasibility check was performed for each HFE. This included defining both a cognitive and execution procedure, identify the frequency and level of training, showing there is enough time to complete the

ULNRC-05908 September 24, 2012 Page 51 of 77 action, and there are enough people available to perform all tasks associated with the initiating event.

3. Quantify - The HEP is quantified using the EPRI HRA approach which accounts for a combination of cognitive and execution performance shaping factors.
4. Uncertainty - The uncertainty is addressed both qualitatively and quantitatively in the HRA.

As part of the HRA update no procedure updates to improve the SAMA were identified.

A case was quantified to determine the benefit of automating the initiation of CCW flow to the RHR heat exchangers. This case was evaluated by setting the value of basic event OP-XHE-FO-CCWRHX to 0.0. The benefit of this modification was determined to be $62K with the 95% CDF benefit being $132K. This modification was judged to be not cost-beneficial.

The cost of adding hardware systems to automatically perform the actions represented by important human actions is high. This cost has been shown in a number of SAMA submittals to sometimes be order(s) of magnitude higher than the benefit achieved.

Other non-procedural changes such as additional maintenance and testing would not necessarily reduce risk significant human errors. Most equipment related failures are induced by human errors during testing or maintenance. The benefits of increasing the occurrence of tests and maintenance diminish at the point where additional maintenance or restoration errors are introduced or at the point where undue wear and tear occurs. Callaway's maintenance and testing program uses vendor recommended test and maintenance intervals as well as operating experience in an attempt to optimize mechanical reliability. Randomly increasing test and maintenance over the recommended intervals is perceived to have no mechanical reliability benefit; but would pose an increase in maintenance and restoration errors as well as wear and tear.

e. In Tables 3-2, 3-6, and 3-7, the SAMAs associated with the various basic events in many cases are identified by generic titles such as "Service Water SAMAs," or "Safety Injection SAMAs," rather than citing specific SAMAs that address the failure associated with the basic event. Also, these SAMA categories do not correlate to SAMA categories identified in Table 5-1. For example the categories "Service Water SAMAs," and "Safety Injection SAMAs," are not identified in the fourth column of Table 5-1. In light of this and the fact that only three SAMAs are identified in Table F.5-1 as a result of the importance analysis, the extent of the effort made to identify Callaway specific SAMAs for the important failures is not clear. Within Tables 3-2, 3-6, and 3-7, clarify which SAMA(s) address each specific basic event.

Also, please provide a general description of this mapping.

ULNRC-05908 September 24, 2012 Page 52 of 77

Response

Tables F.3-2, 3-6 and 3-7 have been revised to address RAIs 5e and 5f, and are provided in Enclosure 3.

f. In importance analyses Tables F.3-2, 3-6, and 3-7, some basic events are not assigned a candidate SAMA but rather with the notation that they are initiating events (i.e., IE-T3, IE-TMSO, IE-S3, IE-T2). Identify SAMAs for these initiating events that either reduce their frequency or mitigate their impact.

Response

Tables F.3-2, 3-6 and 3-7 have been revised to address RAIs 5e and 5f, and are provided in Enclosure 3.

g. Table F.6-1 indicates that SAMA 3 (add additional battery charger or portable diesel-driven battery charger to existing direct current (DC) system) is screened out on the basis that the intent of this SAMA is met by having two spare battery chargers. This SAMA also includes a diesel driven battery charger. Clarify whether Callaway has a diesel charger that could be considered as part of candidate SAMA and evaluate if appropriate.

Response

Callaway Energy Center maintains a portable diesel generator capable of supplying any single train of the existing 125V DC (system NK) electrical busses. Emergency Coordinator Supplemental Guidelines, Attachment N, "Temporary Power to NK Swing Chargers provides procedural guidance on uses the portable generator to provide power to the NK system swing battery chargers.

h. Provide additional information describing the basis for the screening of SAMA 16 (improve uninterruptible power supplies) in Table 6-1.

Include explanation of what upgrades were made and for any upgrades made, identify which frontline system those uninterruptible power supplies support.

Response

The modification replaced the existing Class IE 120 VAC inverters to add a standby regulated 120 VAC source and associated automatic transfer switches to form a complete inverter/uninterruptible power supply (UPS). The automatic transfer function will transfer the 120 VAC load to the standby source in the event of inverter or DC system failure without interruption to the power supply.

ULNRC-05908 September 24, 2012 Page 53 of 77 The UPSs supply power to the following systems:

  • Engineered Safety Feature Actuation System (ESFAS)
  • Neutron Flux Monitor
  • Ex-Core Neutron Flux Monitor
  • Solid State Protection System
  • Nuclear Instrumentation (NIS) Cabinet
  • Control Room fire isolation panel
  • BOP instrument racks
  • Safety Related instrument racks
  • Subcooling Monitor
  • Relay racks
i. Clarify whether remote operation of the atmospheric steam dumps (ASDs), cited in the disposition of SAMA 40 in Table 6-1, is possible and could be credited for risk reduction using the PRA model used to perform the SAMA analysis.

Response

Emergency Coordinator Supplemental Guidelines, Attachment S Manual Control of ABPHC0002 to Control ABPV0002, and Attachment T Manual Control of ABPHC0003 to Control ABPV0003, provide direction to operators on local manual operation of the ASDs.

Plant personnel are trained on the use of protective equipment and breathing apparatus that may be required in order to access the controllers in adverse environmental conditions. Given this guidance it may be possible to credit this action to reduce risk; however, this capability is not modeled in the PRA used to develop the SAMA.

j. In Table F.6-1, SAMAs 81, 82, and 83 were screened on the basis that the intent of these heating, ventilation, and air conditioning (HVAC)

SAMAs was met at Callaway. In light of the fact that just one general HVAC SAMA (i.e., SAMA 80) was evaluated, please provide further justification for screening out these SAMAs.

Response

SAMAs 81 and 83 suggested installation of high temperature alarms in the diesel generator rooms and switchgear rooms respectively. These SAMAs were screened as being met because high temperature alarms exist at Callaway for these areas.

SAMA 82 deals with staging portable fans as a backup to switchgear room ventilation. This item was screened as intent met since

ULNRC-05908 September 24, 2012 Page 54 of 77 procedures exist at Callaway for opening doors to provide alternate cooling capability should switchgear room ventilation be lost. Analysis has shown that only opening doors is necessary and the use of portable fans is not required.

As part of the Callaway PRA, room heat-up calculations have been performed to determine those areas that require ventilation to prevent equipment failure. For those areas that require ventilation, the SAMA case HVAC was evaluated by removing the HVAC dependency for these areas in the PRA.

k. In Table F.6-1, SAMA 137 (Provide capability to remove power from the bus powering the control rods) has the following Phase I disposition: "Response procedure in place." Confirm that this procedure includes removing power from the bus powering the control rods.

Response

Procedure FR-S.1, Response to Nuclear Power Generation/ATWS, provides direction to the Operators to remove power from the busses (PG19 and PG20) powering the control rods. This action is performed within the Control Room and is included in the Licensed Operator training program.

l. In Table F.6-1, SAMA candidate 138 (improve inspection of rubber expansion points on main condenser) is screened out as "Not Applicable" with the disposition that, "No risk significant flooding sources identified in the turbine building." Although the current internal events PRA is stated not to include analysis of internal flooding, the Callaway IPE indicates that internal flooding contributed 31 percent to internal events CDF. Clarify whether this flooding source is possible and whether it can be risk significant. If it can, provide an evaluation for this SAMA.

Response

The condenser expansion joints are a potential flooding source. The original and updated IPE internal flooding assessment did not identify this flooding source as impacting any safety related equipment. The flooding analysis used to develop the SAMA did not identify this flooding source as risk significant.

The Callaway Internal Flooding analysis was updated again following the submittal of the License Renewal LAR. This updated analysis estimated the risk associated with all circulating water floods, including

ULNRC-05908 September 24, 2012 Page 55 of 77 large expansion joint floods, in the turbine building to be approximately 5E-08/yr which is less than 1 percent of the total flooding CDF.

m. In Table F.6-1, SAMA 141 (provide additional restraints for carbon dioxide (C02) tanks) is combined with other seismic SAMAs (i.e., 154, 155,156,157,158, and 159). None of these SAMAs address this specific issue. Justify why these SAMAs are combined or evaluate them separately.

Response

The intent was to address generic seismic SAMAs with individual plant specific seismic issues. SAMA 141 could have been screened as Not Applicable for Callaway. The topic of SAMA 141 (provide additional restraints for carbon dioxide (CO2) tanks) was not identified as a seismic issue to be corrected during the IPEEE seismic analysis and Callaway has no CO2 fire suppression systems within the powerblock.

The AEPS diesel generators do have a CO2 suppression system that is not seismically qualified; however the AEPS diesel generators themselves are not seismically qualified and may not survive a seismic event.

n. In Table F.6-1, SAMA candidate 144 (install additional transfer and isolation switches) for reducing the potential for spurious actuation during a fire is screened out as "Intent Met" based on modification commitments made in the NFPA 805 LAR submittal. NFPA 805 LAR Attachment S does identify such an item (i.e., Item 070151 -Install redundant fuses and switches to prevent multiple spurious actions from stopping or starting safety equipment). However, this modification is specific to selected cables in the Main Control Room to Train B fed from NB02. Justify or evaluate other modifications that would reduce spurious actuations during a fire.

Response

The following modifications were identified by the NFPA 805 project.

The NFPA 805 project did not consider any other modifications to be necessary.

Modification 07-0066 - The buried carbon steel ESW piping was replaced with high density polyethylene (HDPE) piping. During the piping replacement the cabling associated with DFTE0067A and 68A was relocated to restore the required 20 foot separation criteria. This modification is complete. This modification was not assigned a specific SAMA since it is already complete.

Modification 10-0032 - Installed a non-safety related AFW pump as diverse AFW backup supply to the safety related motor driven and

ULNRC-05908 September 24, 2012 Page 56 of 77 turbine driven pumps. This modification is complete. This modification is related to SAMAs 68 and 78.

Modification 10-0038 - Install four non-safety related diesel generators (8MW) at the electric cooperative substation. Either the electrical cooperative substation or the 4 non-safety diesel generators will be able to power either Safety Related bus in the event of a loss of AC power and failure of the Emergency Diesel Generators. This modification is complete. This modification is related to SAMAs 9 and 14.

Modification 05-3029 - Install lower amperage fuses for various 14 AWG control circuits in the MCR. The majority of the modification centers around the trip circuit fuses on NB, NG, PA, PB, and PG system breakers. This modification is not complete. This modification was added as SAMA 180.

Modification 07-0151 - Install redundant fuses and isolation switches for MCR evacuation procedure OTO-ZZ-00001. This modification is not complete. This modification was added as SAMA 181.

Modification 09-0025 - To protect against multiple spurious operation scenarios, cable runs will be changed to run a single wire in a protected metal jacket such that spurious valve opening due to a hot short affecting the valve control circuit is eliminated for the fire area.

This modification will be implemented in multiple fire areas. This modification is not complete. This modification was added as SAMA 182.

Modification 12-0009 - Quick response sprinkler heads in cable chases A-11, C-30, and C-31 will be modified to be in accordance with the applicable requirements of NFPA 13-1976 edition. This modification is not complete. This modification was added as SAMA 183.

o. Table 5-1 includes in Note 1 SAMA identification sources to include "D. Expert panel convened to review SAMA analysis." Section 5.5 of the LRA states that "The Callaway plant staff provided plant specific items that were included in the evaluation." Describe this activity in more detail. identifying the individuals involved and how the review was conducted. In addition, please clarify whether the "Expert Panel" was a formal panel or several individuals reviewing material individually.

ULNRC-05908 September 24, 2012 Page 57 of 77

Response

The Expert Panel convened to review the SAMA analysis was a formal panel that met over a two day period. The panel was made up of the following personnel:

  • Supervising Engineer, Plant Life Extension (Facilitator)
  • Mechanical Design Engineer
  • Operations Supervisor
  • Engineering Fix-It-Now Mechanical Engineer
  • (Scientech), PRA Engineer/Senior Scientist The panel first reviewed the Phase I screening results for concurrence. The Panel then reviewed the Phase II screening. In Phase II, each SAMA item was discussed and any questions on how the calculated benefit was determined. In many cases the SAMA analysts had determined an estimated cost based on previous SAMA submittals. If so, the Expert Panel would decide to agree or revise the cost estimate. For other SAMAs, the panel members discussed how the potential modification could be implemented and determined simple minimum cost based on the costs to install similar modifications in the past. The Panel used the 95% CDF sensitivity benefit as the benefit for cost/benefit comparison. The cost estimates and design inputs were only discussed in enough detail to determine that the implementation costs would be significantly greater than the 95% CDF sensitivity benefit.

During this review process, a few members of the Expert Panel brought up possible SAMA items that were generated by the discussions. These were added to the list of SAMA items.

6. With regard to the Phase II Cost-Benefit Evaluations:
a. Provide the percent reduction in off-site economic cost risk (OECR) for each SAMA evaluated in Table F.7-1 and any other SAMAs evaluated in response to RAls.

ULNRC-05908 September 24, 2012 Page 58 of 77

Response

Table F.7-1 has been revised to include the percent reduction in off-site economic cost risk (OECR) for each SAMA item in the table. The updated table is included in Attachment 1 to this enclosure. The percent reduction was calculated by dividing the Total Offsite Benefit for each SAMA case by the Total Offsite Risk calculated for the baseline PRA case.

b. ER Section F.7.2 indicates that an expert panel developed the implementation cost estimates for each of the SAMAs. Describe the level of detail used to develop the cost estimates (i.e., the general cost categories considered). Also, clarify whether the cost estimates accounted for inflation, contingency costs associated with unforeseen implementation obstacles, replacement power during extended outages required to implement the modifications, and maintenance and surveillance costs during plant operation.

Response

The general categories of costs considered were materials, analyses to support implementation and feasibility, procedure development, replacement power costs, and the costs of ongoing training and surveillance. Inputs such as cost of implementation at other plants and implementation of similar modifications and equipment replacements were also considered. Some estimates included costs of a structure to house the equipment if the Expert Panel felt that sufficient space did not exists within the current plant structures. In general, the discussion for an individual item would start out relatively low and more detail and refinement would take place after comparison of the cost estimate to the benefit at 95% CDF, which was always the highest benefit from the sensitivity evaluations.

The cost estimates did not consider inflation. Contingency costs were not specifically considered. Members used the costs of similar modifications as a basis for their input to the cost estimates and those modifications may have included varying amounts of contingency costs.

c. Confirm which CDF value and contributors (e.g., internal and external) were used to calculate the risk reduction values presented in Table F.7-1. Table F.7-1 presents the reduction in CDF for SAMA 2 as 12.17 percent. This is evaluated as eliminating SBO events. Table F.3-1 presents a value for SBO that is 28 percent of the total. Please explain this discrepancy.

ULNRC-05908 September 24, 2012 Page 59 of 77

Response

The values shown in the original Table F.3-1 were incorrect. The original value shown in this table classified sequences with failure of the EDGs with power successfully provided from the AEPS diesel generators as a station blackout. A revised table is provided below that classifies those sequences as Loss of Offsite Power sequences.

Table 3-1. Contributions to Internal Events CDF Contribution to Internal CDF Initiating Event Type (/year)

Small LOCA 5.93E-06 Loss of Offsite Power 3.98E-06 SGTR 2.35E-06 RCP Seal LOCA 8.63E-07 Reactor Trip 7.88E-07 Station Blackout 7.85E-07 Intermediate LOCA 3.67E-07 All Steam Line Breaks 3.35E-07 Anticipated Transient without Scram (ATWS) 2.04E-07 ISLOCA 1.73E-07 Loss of Feedwater 1.65E-07 Very Small LOCA 1.29E-07 Loss of CCW 1.20E-07 Loss of SW 1.15E-07 Feedwater Line Break 9.01E-08 Loss of DC Vital Bus 6.93E-08 PORV Fails to Reclose 4.52E-08 Large LOCA 4.21E-08 Total 1.66E-05 LOCA = loss of coolant accident; SGTR = steam generator tube rupture; RCP = reactor coolant pump; CCW = component cooling water; SW = service water; DC = direct current; PORV =

power operated relief valve

d. Clarify modeling assumptions used for SAMA cases in which failures are eliminated (e.g., service water pumps) by indicating which failures were eliminated including whether this includes support failure (e.g.,

mechanical failure of service water pumps and support failures such as alternating current (AC) power supply to service water pumps).

Response

Descriptions of the changes made to the PRA model for each SAMA case are shown below. Preparation of the response determined that cases NOSGTR and NOSLOCA needed revision and these cases were re-quantified. New SAMA cases created in response to the RAIs

ULNRC-05908 September 24, 2012 Page 60 of 77 have been added. The revised results are included in the revised tables F7-1, F8-1, and F11-1 which are included in Attachment 1 to this enclosure.

NOATWS SB-ICC-AF-RXTRIP BB-BKR-CC-TRPBKR BB-RCA-WW-RCCAS The above basic events represent reactor trip failure modes and are set to 0.0 in BED file SAMANOATWS.BED. There are no modeled support systems associated with these failure events.

This case is used to determine the benefit of eliminating all Anticipated Transient Without Scram (ATWS) events. For the purposes of the analysis, a single bounding analysis was performed which assumed that ATWS events do not occur.

NOSGTR IE-TSG L2-SGT-VF-PISGR L2=SGT-VF-TISGR The above basic events were set to 0.0. The basic events represent the Steam Generator Tube Rupture initiating event and the probability of pressure and thermally induced tube ruptures. This allows evaluation of various possible improvements that could reduce the risk associated with SGTR events. For the purposes of this analysis, a single bounding analysis was performed which assumed that SGTR events do not occur.

INSTAIR KA-PSF-VF-ISTAIR KA-PSF-VF-TKA02 KA-PSF-VF-TKA03 KA-PSF-VF-TKA04 KA-PSF-VF-TKA05 The above basic events are set to 0.0 in BED file SAMAINSTAIR.BED. The PRA model does not contain detailed modeling of the instrument air system. The first basic event represents failure of the instrument air system. The others represent failures of the steam generator PORV backup nitrogen supply.

Support system failures were not directly considered in this case.

This case is used to determine the benefit of replacing the air compressors. For the purposes of the analysis, a single bounding condition was performed, which assumed the station air systems do not fail.

ULNRC-05908 September 24, 2012 Page 61 of 77 NOLOSP IE-T1 The above basic event is set to 0.0 in BED file SAMANOLOSP.BED.

This eliminates the Loss of Offsite Power initiating event.

This case is used to determine the benefit of eliminating all Loss of Offsite Power (LOSP) events, both as the initiating event and subsequent to a different initiating event. This allows evaluation of various possible improvements that could reduce the risk associated with LOSP events. For the purposes of the analysis, a single bounding analysis was performed which assumed that LOSP events do not occur.

CCW01 EG-MDP-CR-EGPMP3 EG-MDP-DR-EGPMP4 EG-MDP-DS-EGPMP3 EG-MDP-DS-EGPMP4 EG-MDP-FR-PUMPA EG-MDP-FR-PUMPB EG-MDP-FR-PUMPC EG-MDP-FR-PUMPD EG-MDP-FS-PUMPA EG-MDP-FS-PUMPB EG-MDP-FS-PUMPC EG-MDP-FS-PUMPD The above basic events are set to 0.0 in BED file SAMACCW01.BED.

These basic events represent failures of the CCW pumps. This case did not consider support system failures.

This case is used to determine the benefit of improvement to the CCW system by assuming that CCW pumps do not fail.

FW01 IE-T2 The above basic event is set to 0.0 in BED file SAMAFW01.BED. This eliminates the loss of feedwater initiating event.

Eliminate loss of feedwater initiating events. This case is used to determine the benefit of improvements to the feedwater and feedwater control systems.

NOSLB IE-TMSI IE-TMSO The above basic events are set to 0.0 in BED file SAMANOSLB.BED.

This eliminates the steam line break initiating events, both inside and outside containment.

This case is used to determine the benefit of installing secondary side guard pipes to the Main Steam Isolation Valves (MSIVs). This would

ULNRC-05908 September 24, 2012 Page 62 of 77 prevent secondary side depressurization should a Steam Line Break (SLB) occur upstream of the MSIVs. For the purposes of the analysis, a single bounding analysis was performed which assumed that no SLB events occur.

CHG01 The fault trees were modified to remove the cooling water dependency for the charging pumps. This assumes the charging pumps are not dependent on cooling water. This case is used to determine the benefit of removing the charging pumps dependency on cooling water.

No other support system modifications were made.

SW01 The Essential Service Water system fault trees were modified to remove the dependency on DC power. This assumes the Essential Service Water pumps are not dependent on DC power. This case is used to determine the benefit of enhancing the DC control power to the Essential Service Water pumps. No other support system modifications were made.

NOSBO NE-DGN-DR-NE01-2 NE-DGN-DS-NE01-2 NE-DGN-FR-NE01 NE-DGN-FR-NE01-2 NE-DGN-FR-NE01-8 NE-DGN-FR-NE0110 NE-DGN-FR-NE0112 NE-DGN-FR-NE02 NE-DGN-FR-NE02-2 NE-DGN-FR-NE02-8 NE-DGN-FR-NE0210 NE-DGN-FR-NE0212 NE-DGN-FS-NE01 NE-DGN-FS-NE02 NE-DGN-TM-NE01 NE-DGN-TM-NE02 The above basic events represent failures of the emergency diesel generators and are set to 0.0 for this case. Failures of the EDG support systems were not modified. This case is used to determine the benefit of eliminating all Station Blackout (SBO) events. This allows evaluation of possible improvements related to SBO sequences. For the purpose of the analysis, a single bounding analysis is performed that assumes the emergency AC power supplies do not fail.

ULNRC-05908 September 24, 2012 Page 63 of 77 LOCA05 IE-A IE-S1 IE-S2 IE-S3 The above basic events represent the initiating events Large LOCA, Medium LOCA, Small LOCA, and Small-Small LOCA. For this case these events were set to 0.0 to represent that piping system LOCAs do not occur. This case is used to determine the benefit of eliminating all LOCA events related to piping failure (no change to non-piping failure is considered).

NOSLOCA IE-S2 IE-S3 BB-PRV-OC-V455A BB-PRV-OC-V456A The above basic events were set to 0.0. These basic events represent the small and small-small LOCA initiating events and the failure of the PORVs to close following an opening. These values were applied to the model modification used to evaluate RCP seal LOCAs. No other support system modifications were made.

This case is used to evaluate the elimination of all small LOCAs, from pipe breaks, stuck open PORV, and RCP seal LOCA.

H2BURN L2-CNT-VF-CFE1 L2-CNT-VF-CFE5 The above basic events were set to 0.0. These basic events represent the probability of containment failure due to hydrogen burns.

Assume hydrogen burns and detonations do not occur. This case is used to determine the benefit of eliminating all hydrogen ignition and burns.

RCPLOCA Created new data file SAMARCPLOCA.BED with a single basic event, NORCPLOCA, with value 0.0. The fault tree for RCP seal LOCA was modified to add this event under the AND gate representing causes of RCP seal failures. This logically eliminates all seal failure causes from the calculation.

This case is used to determine the benefit of eliminating all Reactor Coolant Pump (RCP) seal loss of coolant accident (LOCA) events.

This allows evaluation of various possible improvements that could reduce the risk associated with RCP seal LOCA and other small LOCA events.

ULNRC-05908 September 24, 2012 Page 64 of 77 LOCA02 Created new BED file SAMAEVNTZERO.BED with a single basic event, EVNTZERO, with value 0.0. Modified fault trees 1OF4HPI, 1OF4HPR, and 14HPI1S to add event EVNTZERO as input to top AND gate. Modified fault trees HPCI-1, HPCI-2, HPCR-1, and HPCISBO to change to single top gate with only event EVNTZERO as input. No changes to support system logic were made.

This case is used to determine the benefit of no failures of high pressure injection/recirculation systems. This allows evaluation of various possible improvements that could reduce the risk associated with high pressure injection/recirculation failures.

LOCA12 BG-MDP-DR-CCPS BG-MSP-DS-CCPS BG-MDP-FR-CCPA BG-MDP-FR-CCPB BG-MDP-FR-NCP BG-MDP-FS-CCPA BG-MDP-FS-CCPB BG-MDP-FS-NCP BG-MDP-TM-CCPA BG-MDP-TM-CCPB EM-MDP-DR-SIPMPS EM-MSP-DS-SIPMPS EM-MDP-FR-PEM01A EM-MDP-FR-PEM01B EM-MDP-FS-PEM01A EM-MDP-FS-PEM01B EM-MDP-TM-PEM01A EM-MDP-TM-PEM01B The above basic events represent failures of safety injection and charging pumps and are set to 0.0 for this case. Failures of the support systems were not modified. This case is used to determine the benefit of no failures of high pressure injection/recirculation pumps. This allows evaluation of various possible improvements that could reduce the risk associated with high pressure injection/recirculation pump failures.

ULNRC-05908 September 24, 2012 Page 65 of 77 CONT02 The results equation for failure of containment isolation was set to 0.0.

This case is used to determine the benefit of no containment isolation failures. This allows evaluation of various possible improvements that could reduce the risk associated with all containment isolation failures.

LOCA04 BN-TNK-FC-RWSTUA The above basic event represents unavailability of the RWST and is set to 0.0. No support system modifications were made.

This case is used to determine the benefit of additional RWST inventory. This allows evaluation of various possible improvements that could reduce the risk associated with RWST inventory by assuming that the RWST does not run out of water.

CONT01 The results equation for late containment failure due to containment overpressure was set to 0.0.

This case is used to determine the benefit of no containment overpressure failures. This allows evaluation of various possible improvements that could reduce the risk associated with all containment overpressure failures.

LOCA03 EJ-MDP-DR-EJPMPS EJ-MDP-DS-EJPMPS EJ-MDP-FR-PEJ01A EJ-MDP-FR-PEJ01B EJ-MDP-FS-PEJ01A EJ-MDP-FS-PEJ01B The above basic events represent failures of the RHR pumps and are set to 0.0 for this case. Failures of the support systems were not modified.

This case is used to determine the benefit of no failures of low pressure injection/recirculation pumps. This allows evaluation of various possible improvements that could reduce the risk associated with low pressure injection/recirculation pump failures.

SW02 Created new BED file SAMASW02.BED with the following basic events set to 0.0.

EF-MDP-DR-EFPMPS EF-MDP-DS-EFPMPS EF-MDP-FR-PEF01A EF-MDP-FR-PEF01B EF-MDP-FS-PEF01A EF-MDP-FS-PEF01B

ULNRC-05908 September 24, 2012 Page 66 of 77 EF-PSF-TM-ESWTNA EF-PSF-TM-ESWTNB The above basic events represent failures of the ESW pumps and are set to 0.0 for this case. Failures of support systems were not modified. This case is used to determine the benefit of no failures of Essential Service Water pumps.

DC01 The AFW fault trees were modified to remove the dependency on DC power for the TDAFW pump. No other support system modifications were made.

This case is used to determine the benefit of removing TDAFW pump dependency on DC power. This allows evaluation of various possible improvements that could reduce the risk associated with the TDAFW pump dependency on DC power.

CCW02 This case combined cases CCW01 and SW02. This represents failures of the CCW and ESW pumps. No support system modifications were made.

Sets all CCW pumps and ESW pumps to 0.0 to evaluate the benefit of backup cooling water supplies.

ISLOCA The results spreadsheet release category LERF-IS was set to 0.0.

This case is used to determine the benefit of eliminating intra-system LOCA failures. This allows evaluation of various possible improvements that could reduce the risk associated with all intra-system LOCA failures.

LOSP1 Basic event TORNADO-T1-EVENT was set to 0.0. This basic event is the probability that a Loss of Offsite Power Event was caused by a tornado.

This case is used to determine the benefit of no tornado-related failures of the Alternate Emergency Power System (AEPS). This allows evaluation of various possible improvements that could reduce the risk associated with tornado induced failures of AEPS by providing tornado protection for the AEPS diesel generators and associated circuits.

DEPRESS In Fault tree DEPRESS.LGC gate GDEP100 was changed to an AND gate and a new basic event, EVENTZERO, was added as an input and set to 0.0.

This case is used to determine the benefit of no failures of depressurization. This allows evaluation of various possible

ULNRC-05908 September 24, 2012 Page 67 of 77 improvements that could reduce the risk associated with depressurization failures by eliminating depressurization failures.

LOCA06 Basic event IE-A was set to 0.0. This eliminates the Large LOCA initiating event. No support system changes were made.

This case is used to determine the benefit of eliminating Large LOCAs. This allows evaluation of various possible improvements that could reduce the risk associated with all Large LOCA events.

HVAC The fault trees for AFW, Safety Injection, RCP Seal Cooling, Emergency Diesel Generators, and DC power were modified to remove the dependency on room cooling. No other support system changes were made.

These changes eliminate various HVAC dependencies. This allows evaluation of various possible improvements that could reduce the risk associated with failures of various HVAC systems.

FB01 The fault trees were changed to replace the logic requiring two PORVs for successful feed and bleed with the logic for only one PORV required for feed & bleed. No support system modifications were made.

This case was used to evaluate modifying the PORVs such that only one PORV is required for Feed and Bleed.

PORV BB-PRV-CC-V455A BB-PRV-CC-V456A The above basic events were set to 0.0. These basic events represent failure of the PORVs to open. No support system changes were made.

This case was used to evaluate improvements that lower the probability of PORVs failing to open.

EDGFUEL The fault trees for the emergency diesel generators were modified to eliminate the dependency on the fuel oil transfer system. No other support system modifications were made.

This case was used to evaluate the addition of a gravity feed EDG fuel oil tank.

ULNRC-05908 September 24, 2012 Page 68 of 77 FW02 AE-CKV-CC-AEV120 AE-CKV-CC-AEV121 AE-CKV-CC-AEV122 AE-CKV-CC-AEV123 AE-CKV-DF-V120-3 The above basic events represent failure of the feedwater check valves to open and were set to 0.0 for this case. No support system changes were made.

This case was used to evaluate improvements that lower the probability of feedwater check valves failing to open.

SW03 The fault trees for the SW System Train A were modified to add AEPS as a possible power source. No other support system modifications were made.

This case was used to evaluate adding the ability to power the normal service water pumps from the AEPS.

HVAC02 VD-FAN-DR-GD02AB VD-FAN-DS-GD02AB VD-FAN-FR-CGD02A VD-FAN-FR-CGD02B VD-FAN-FS-CGD02A VD-FAN-FS-CGD02B The listed basic events represent failures of the fans for the UHS cooling tower electrical room and were set to 0.0 for this case. No other support system modifications were made.

This case was used to evaluate adding additional UHS cooling tower electrical room HVAC.

CST01 The probability for basic event AD-TNK-FC-CSTUNA (Condensate Storage Tank Unavailable) to 0.0. Supporting analysis for the PRA shows that the CST does not deplete within the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> PRA mission time so this is the only PRA manipulation required. No other support system modifications were made.

This case was used to evaluate adding a second CST or expanding the capacity of the current CST.

HEP Basic event OP-XHE-FO-CCWRHX (Operator fails to initiate CCW flow to the RHR HXs) was set to 0.0. No other support system modifications were made.

This case was used to support the response to RAI 5.d.iii.

ULNRC-05908 September 24, 2012 Page 69 of 77 RAI7a Basic event L2-SGT-VF-TISGR was set to 0.0 for this evaluation. This basic event represents the probability of a thermally induced steam generator tube rupture. No other support system modifications were made.

This case was used to evaluate the impact of a procedure change to prevent the operators from clearing the RCS cold leg loop seal following core damage (RAI 7.a).

SLIS Basic events SA-ICC-AF-MSLIS, SA-ICC-AF-MSLIS1, SA-ICC-AF-MSLIS4 were set to 0.0. These basic events represent the failure of the main steam line isolation system. No support system modifications were made.

This case is used to evaluate improvements in the main steam line isolation system.

FWCCW2 The RHR fault trees were modified to add fire water as a backup source of cooling to the RHR heat exchangers. The fire water pumps and system do not appear in the PRA. To simulate the use of the fire water pumps and operator actions to perform the temporary hookup, a single basic event with failure probability of 0.1 was placed in the fault trees.

This case is used to evaluate the benefit of providing a temporary hookup of fire water to the RHR heat exchangers.

e. For certain Phase II SAMAs listed in Table F.7 -1, the information provided does not sufficiently describe the associated modifications to clearly identify what is included to justify the cost estimates. Provide a more detailed description of the modifications and cost estimates for SAMAs 11, 15, 64, 94, 104, 116, 163, and 164.

Response

The process used to determine the cost of potential modification was to have the Expert Panel draw on their knowledge and experience with previous modifications and costs estimated in SAMA submittals from other plants. The modification needed was discussed in general terms unless the cost appeared to be close to being potentially cost-beneficial. In some cases, preliminary cost estimates existed for proposed design modifications that would implement either the SAMA being described or a similar modification.

For SAMA 11, the cost estimate considered the analysis required to support the implementation, materials to be purchased and pre-staged, the development of procedures to support the implementation of the cross-tie, the initial and continuing training of personnel on how to implement the cross-tie procedure, and the cost of periodic inspections to ensure all pre-staged material and equipment is present.

ULNRC-05908 September 24, 2012 Page 70 of 77 For SAMA 15, the cost estimate was based on a preliminary design that was considered at the time the AEPS diesel generators were constructed and installed.

The benefit of SAMA 64 would be better estimated by using the benefit calculated for case SW02 (no failures of ESW pumps) rather than case CCW01 (no failures of the CCW pumps). Using this case benefits, the development of temporary procedures to use fire water to cool the CCW heat exchangers is potentially cost beneficial. This SAMA has been added to the list of potentially cost-beneficial SAMAs.

The discussion for SAMA 94 determined that a suitable containment penetration that could be used for this filtered vent does not exist. It was estimated that creating a new containment penetration would cost in excess of $1M. The cost of purchase and installing the new equipment was estimated to cost in excess of $1M. No further costs were added to estimate, so the additional costs of procedures, training, on-going testing and inspection were not included.

The discussion for SAMA 104 noted that most of the piping to be inspected is located inside containment. In order to reduce the radiation dose during the inspections, the plant would be required to either significantly reduce power or shut down. The replacement power costs required to perform the inspections was estimated to be in excess of $2M.

The discussion of SAMA 116 noted that the current plant design and licensing basis require the floor drains in these rooms to be open. The cost of analysis and license changes required to support implementation of this SAMA item were determined to be in excess of $1M.

The discussion for SAMA 163 noted that the feedwater check valves were previously replaced to improve reliability. The cost of replacement in the past exceeded $500K.

The cost estimate for SAMA 164 included an estimate of the cost of cabling and wall penetrations for running the cable. Due to the distance involved, the cost was estimated to exceed $500K.

f. For certain Phase II SAMAs listed in Table F.7-1, the calculated benefit does not seem consistent with the percent reduction in CDF or off-site dose or there was no CDF or off-site dose information to compare to the calculated benefit. Provide corrections or more justification for the benefit calculated for SAMAs 39, 160,161, 162, 163, 164, and 171.

Response

The information was added to table F.7-1 for SAMAs 161, 162, 163, 164, and 171.

The original submittal included this information for SAMA 39, but did not for SAMA 29. This response assumes that the question is concerning SAMA 29.

The Expert Panel concluded that SAMA items 29 and 160 were potentially cost-beneficial without determining an actual cost or benefit. These two items were considered to be relatively low cost for implementation and should therefore be

ULNRC-05908 September 24, 2012 Page 71 of 77 entered into the Callaway long-range plan development process for further consideration. Determination of a numerical benefit of SAMA item 160 is not directly possible since the existing Callaway Internal Flooding study is not quantifiable and does not include this flood propagation path.

g. In Table 7-1, SAMA 1 (add additional DC battery capacity) is evaluated by eliminating turbine driven auxiliary feed water (TDAFW) pump dependency on DC power while SAMA 2 (replace lead-acid batteries with fuel cells) is evaluated by eliminating all SBO. For SAMA 1 and SAMA 5 (provide DC bus cross ties also evaluated by eliminating the TDAFW pump DC dependency), describe whether the TDAFW pump availability is the only impact of the loss of DC. Both SAMAs 1 and 2 extend DC power availability during SBO. Explain the reasons for the different evaluations that do the same thing.

Response

Tables F7-1 and F8-1 have been revised, and included in Attachment 1, to reflect case NOSBO for SAMA 1. The Expert Panel cost estimate considers the cost of material (batteries, chargers, and cables), a structure to house the new equipment, and ongoing battery monitoring and testing. For SAMAs 1, 2, and 5 in addition to the TDAFW pump dependency, loss of DC impacts the availability of instrumentation. Emergency Coordinator Supplemental Guidelines exist for the use of portable generators to provide backup power on extended SBO events.

This backup portable power is not credited in the PRA.

h. SAMA 15 (install tornado protection on gas turbine generator) is evaluated by SAMA case LOSP1 which is described as leading to no tornado LOSP events. Given Callaway has alternate emergency power system (AEPS) diesel generators rather than a gas turbine, clarify the model changes made and their applicability to this SAMA.

Response

The AEPS diesel generators are not located in a tornado resistant building. The intent of this SAMA was interpreted to be providing a tornado resistant building for the AEPS diesel generators. The case LOSP1 was evaluated by setting basic event TORNADO-T1-EVENT (conditional probability that a Tornado event initiates a LOSP event and directly causes the loss of AEPS) to a probability of 0.0, which eliminates tornado induced AEPS failures. This allows the determination of the benefit of providing tornado protection for the AEPS diesel generators.

i. In Table F.7-1, SAMA 24 (bury off-site power lines) is shown as costing >$3M and as not being cost beneficial. However, the potential benefit of this SAMA is high ($1.2M) and the estimated cost of this SAMA reported in the Seabrook ER (a recent Westinghouse PWR-4 submittal) is lower (>$1 M). Provide a more detailed description of this modification and additional justification for the estimated cost.

Response

In order to provide the necessary benefit, the offsite power lines would need to be buried the full length of the line to next transmission substation. The nearest transmission substation is approximately 21 miles from the site. The industry

ULNRC-05908 September 24, 2012 Page 72 of 77 accepted cost estimate for burying power lines is approximately $1M per mile, thus the modification would cost approximately $21M.

j. Provide additional information on the changes made for SAMA Case LOCA 12 used to evaluate SAMAs 25, 26, and 39. Describe what modeling change was made to eliminate failures of the charging or SI pumps. Include as part of this description whether these assumed failures are limited to LOCAs or if they include failure due to loss of AC.

Response

SAMA case LOCA12 was evaluated by creating a new BED file SAMALC12.BED with the following basic events set to 0.0.

BG-MDP-DR-CCPS BG-MSP-DS-CCPS BG-MDP-FR-CCPA BG-MDP-FR-CCPB BG-MDP-FR-NCP BG-MDP-FS-CCPA BG-MDP-FS-CCPB BG-MDP-FS-NCP BG-MDP-TM-CCPA BG-MDP-TM-CCPB EM-MDP-DR-SIPMPS EM-MSP-DS-SIPMPS EM-MDP-FR-PEM01A EM-MDP-FR-PEM01B EM-MDP-FS-PEM01A EM-MDP-FS-PEM01B EM-MDP-TM-PEM01A EM-MDP-TM-PEM01B These basic events represent direct failures of the two SI and three high pressure charging pumps. Setting these basic events to 0.0 eliminates failures of the pumps to start or run as well as unavailability due to testing or maintenance. This case considered eliminating only failures of the actual pumps and did not eliminate failures due to loss a support system such as AC power. Modifying the model in this way eliminates these direct pump failures from all accident sequences which call for the operation of these pumps.

k. Provide additional information on the changes made for SAMA Case LOCA03 used to evaluate SAMA 28. Describe what modeling change was made to eliminate failures of the low pressure pumps. Include as part of this description whether these assumed failures are limited to LOCAs or if they include failure due to loss of AC.

ULNRC-05908 September 24, 2012 Page 73 of 77

Response

SAMA case LOCA03 was evaluated by creating a new BED file SAMALOCA03.BED with the following basic events set to 0.0.

EJ-MDP-DR-EJPMPS EJ-MDP-DS-EJPMPS EJ-MDP-FR-PEJ01A EJ-MDP-FR-PEJ01B EJ-MDP-FS-PEJ01A EJ-MDP-FS-PEJ01B These basic events represent direct failures of the low pressure injection pumps.

Setting these basic events to 0.0 eliminates failures of the pumps to start or run.

This case considered eliminating only failures of the actual pumps and did not eliminate failures due to loss a support system such as AC power. Modifying the model in this way eliminates these direct pump failures from all accident sequences which call for the operation of these pumps.

l. In Table F.7-1 the benefit for SAMA 39 appears to be excessively high (i.e.,

$748K) when compared to other similar SAMA benefits. Provide corrections as needed.

Response

The current benefit of $748K shown in Table F7-1 for SAMA 39 is a typographical error. The correct benefit value for SAMA 39 is $48K. Table F7-1 has been corrected and included in Attachment 1.

m. Table F.7-1 indicates that SAMA 46 (add a service water pump) was modeled by assuming there were no failures of essential service water (ESW) pumps. Clarify whether modeling of this SAMA case includes ESW pump unavailability due to test and maintenance.

Response

The original PRA case SW02 did not include test and maintenance events. The case was modified to include setting the test and maintenance events to 0.0. The results of the revised case are reflected in the revised Tables F7-1, F8-1, and F11-1 which are included in Attachment 1 to this enclosure.

n. In Table F.7-1, SAMA 94 (install a filtered containment vent to remove decay heat) is shown as >$2M and as not being cost beneficial. However, the potential benefit of this SAMA is high ($1.2M) and the estimated cost of this SAMA reported in the Seabrook ER is lower (>$500K). Provide a more detailed description of this modification and additional justification for the estimated cost.

Response

The Expert Panel discussion for SAMA 94 determined that a suitable containment penetration that could be used for this filtered vent does not exist. It was estimated that designing and licensing of a new containment penetration or modification of an existing penetration would cost in excess of $1M. The cost of procurement, installation and maintenance (including on-going testing and

ULNRC-05908 September 24, 2012 Page 74 of 77 inspections) of the new equipment was estimated to cost in excess of $1M. No further costs were added to estimate, so the additional costs of procedures and training were not included.

o. In Table F.7-1, SAMA 113 (increase leak testing of valves in interfacing systems (IS) LOCA paths) is shown as costing >$1 M and as not being cost beneficial.

However, the potential benefit of this SAMA is moderate ($123K) and the cost of this SAMA seems high, as it does not require hardware modification. The Seabrook ER reports an estimated cost of >$100K for this SAMA. Provide a more detailed description of this modification and additional justification for the estimated cost.

Response

The containment isolation valves in the ISLOCA pathways are currently tested every refueling outage. In order to test these valves the plant must be in Cold Shutdown/Refueling conditions when the valves are accessible and the systems can be aligned/configured to allow installation of test equipment and the performance of the testing. Leak testing on a more frequent basis would require plant shutdown. The cost of replacement power to support shutdowns to test the valves was estimated to be significantly greater than $1M. Callaway currently does not have any regularly scheduled mid-cycle outages. Mid-cycle forced or scheduled outages could produce an opportunity for performing these tests, however any extension of these outages in order to perform leak testing on these valves would quickly accumulate costs that would make this testing not cost-beneficial. Replacement power costs for outage extension is generally estimated to be $1M per day.

p. In Table F.7-1, SAM A 119 (institute a maintenance practice to perform a 100 percent inspection of steam generator tubes during each refueling outage) is shown as costing >$3M and as not being cost beneficial. However, the potential benefit of this SAMA is high ($1.2M) and the cost of this SAMA seems high, as it does not require hardware modification. The Seabrook ER reports an estimated cost of >$500K for this SAMA. Provide a more detailed description of this modification and additional justification for the estimated cost.

Response

Due to the recent replacement of steam generators and the associated reduced inspection requirements, the expert panel estimated that performing a 100%

inspection every refueling outage would extend the duration of many outages. In addition, testing of steam generator tubes requires considerable radiological dose, testing equipment costs and vendor costs for data analysis and reporting.

The sum of these costs is in excess of the estimated $3M for this SAMA.

q. Section F.11 states that the RCPLOCA modeling case "allows evaluation of various possible improvements that could reduce the risk associated with RCP seal LOCA and other small LOCA events." As for other SAMA cases, provide a description of the specific modeling assumptions made to determine the percent reduction in CDF and off-site dose.

ULNRC-05908 September 24, 2012 Page 75 of 77

Response

SAMA case RCP-LOCA was evaluated by using the following changes to the baseline PRA model:

The fault tree that develops Reactor Coolant Pump (RCP) seal loss of coolant accident (LOCA) cutsets, RCP-1, was modified by adding a new basic event called NORCPLOCA to the top gate of the fault tree. When failed, basic event NORCPLOCA prevents the RCP seal LOCA portion of the model from being solved. A new BED file, SAMARCPLOCA.BED, was created with basic event NORCPLOCA failed by setting it to a value of 0.0. This evaluates elimination of all RCP seal LOCA events that are caused by failure of seal cooling and injection except those which occur as a result of a support system initiating event such as loss of CCW.

Case RCP-LOCA used SAMARCPLOCA.BED and the modified fault tree modeling to determine the benefit of eliminating all RCP seal LOCA accident sequences.

th

r. Section F.8.2 indicates that the uncertainty factor used for the ratio of the 95 percentile value to the mean value of the CDF is 2.11. In Table F.8-1, the ratio of th the base cost benefit to the 95 percentile case for SAMAs 91, 93, and 94 appears to be low (i.e., 1.4). Please explain this apparent discrepancy, or if this is th a mistake, recalculate the 95 percentile benefit for these three SAMAs.

Response

The nominal case benefit listed for SAMAs 91, 93, and 94 in Tables F7-1 and F.8.2 is a typographical error. The correct nominal benefit for each is $793K. The listed 95% benefits of $1.7M are correct. Tables F.7-1 and F.8-1 have been revised, and included in Attachment 1, to show the corrected nominal benefit.

s. Table F.7-1 reports the baseline benefit for SAMA 136 to be $53K, whereas Table F.8-1 reports this value as $63K. Provide corrections as needed.

Response

The current benefit shown in Table F.7-1 for SAMA 136 is a typographical error.

The correct benefit value for this SAMA is $63K. Table F.7-1 has been corrected and included in Attachment 1.

th

t. Table F.7-1 reports a 95 percentile benefit for SAMA 24 as 2.4M but should be 2.5M. Provide corrections as needed.

Response

As Table F.7-1 does not list a 95th percentile value, it is assumed that the RAI is referring to Table F.8-1. The current 95th percentile CDF benefit shown in Table F.8-1 for SAMA 24 is a typographical error. The correct 95th percentile CDF benefit value for SAMA 24 is $2.6M. Table F.8-1 has been corrected and included in Attachment 1.

ULNRC-05908 September 24, 2012 Page 76 of 77

u. The NRC staff has been unable to find a description for SAMA case CST01 identified in Tables F.7-1 and F.8-1 of Section F.11. As for the other SAMA cases, provide a description of the case and the specific modeling assumptions made to determine the percent reduction in CDF and off-site dose.

Response

Case CST01 changed the probability for basic event AD-TNK-FC-CSTUNA (Condensate Storage Tank Unavailable) to 0.0 representing perfect reliability of the CST. Supporting analysis for the PRA shows that the CST does not deplete within the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> PRA mission time so this is the only PRA manipulation required to emulate additional CST capabilities such that a CST source is always available.

v. The Section F.11 Annex defines SAMA case "HVAC" as eliminating various HVAC dependencies. Identify which HVAC systems this applies to and how the benefit was calculated. Also, confirm which dependencies this applies to.

Response

This case evaluated equipment dependencies from the following HVAC systems:

  • Motor driven AFW pumps
  • Charging pumps
  • DC switchgear The benefit was calculated by modifying the PRA model to remove the HVAC dependency logic from the fault trees and solving the PRA model.

Case HVAC02 determined the benefit from eliminating all failures of the Ultimate Heat Sink Cooling Tower electrical room HVAC.

All other equipment was shown to not require room cooling through heat-up calculations performed to support the PRA.

Procedural guidance exists for opening doors to the DC switchgear rooms following loss of HVAC. SAMA 80 has been modified to be potentially cost beneficial to provide procedural guidance to open doors or provide temporary ventilation to the EDGs, motor driven AFW pumps, and charging pumps. Loss of HVAC is only an issue for the EDGs if outside ambient temperature is above 60°F.

7. With regard to Alternative SAMAs
a. A note at the end of Table F.5-1 indicates that recent industry submittals of like-kind plants (i.e., Wolf Creek, South Texas, Diablo Canyon, and Seabrook) were used as a source of candidate SAMAs. The extent to which these submittals were examined is not clear, as only two SAMA candidates were identified in Table F.5-1 as being from these sources (i.e., SAMA 162 and 165). Also, it appears that a cost beneficial SAMA identified in the Diablo Canyon submittal might represent an unevaluated SAMA candidate for Callaway (i.e., SAMA 24 - Prevent clearing of

ULNRC-05908 September 24, 2012 Page 77 of 77 RCS cold leg water seals). Describe the extent to which the four cited SAMA submittals were used as sources to generate candidate SAMAs and evaluate each SAMA determined to be cost beneficial in those submittals or show how they could be screened out using criteria presented in ER Section F.6.0. If the SAMA review for a submittal has been completed, use the cost beneficial SAMAs as reported in the respective site specific volume of NUREG-1437, "Generic Environmental Impact Statement for License Renewal of Nuclear Plants."

Response

Response to be provided by separate correspondence.

b. SAMA 64 (implement procedure and hardware modifications to allow manual alignment of the fire water system to the component cooling water system, or install a component cooling water header cross-tie) is evaluated by eliminating CCW pump failures. Consider a similar SAMA that provides fire water to the ESW system.

Response

SAMA 64 was revised to evaluate the benefit of a temporary hookup of fire water as backup on loss of CCW cooling to the RHR heat exchangers. This determined the benefit to be $104K with a 95% CDF benefit of $220K. This SAMA is considered potentially cost beneficial and has been added to the list of potentially cost beneficial SAMAs.

SAMA 186 was added to evaluate procedures to provide fire water to the ESW system. This SAMA was considered potentially cost beneficial based on the 95%

CDF benefit. Implementation of this SAMA will cost significantly more than a procedure change since it would require replacement of the existing fire pumps with larger pumps.

c. Table 7-1 indicates that elimination of all HVAC dependencies for SAMA 80 results in a 6 percent reduction in CDF. The individual HVAC failures listed in Table 3-2 appear to involve unrelated pieces of equipment in various rooms or buildings. Discuss the possibility of lower cost alternatives that address the more important contributors to CDF. Note that two of the above cited failures (VD-FAN-FR-CGD02A and -CGD02B) appear to be the reason for SAMA Case HVAC02 described on Page F-109. This case is not used in the Phase II analyses described in Table 7-1.

Response

SAMA 178 was added to evaluate the cited fan failures and is evaluated using SAMA case HVAC02. Creating a procedure to provide temporary ventilation or opening of doors to provide alternate cooling is potentially cost-beneficial. Table 9-1 has been revised to show this as a potentially cost beneficial SAMA item.

The revised table is included as Attachment 1 to this enclosure.

Information on other HVAC to other areas is included in the response to RAI 6.v.

ULNRC-05908 September 24, 2012 Page 1 of 58 CALLAWAY PLANT UNIT 1 LICENSE RENEWAL APPLICATION REQUEST FOR ADDITIONAL INFORMATION Revised SAMA Tables

ULNRC-05908 September 24, 2012 Page 2 of 58 Table 5-1. List of SAMA Candidates.

Callaway SAMA Focus of Number Potential Improvement Discussion SAMA Source 1 Provide additional DC battery capacity. Extended DC power availability during an SBO station AC/DC 1 blackout (SBO).

2 Replace lead-acid batteries with fuel cells. Extended DC power availability during an SBO. AC/DC 1 3 Add additional battery charger or portable, diesel-driven battery Improved availability of DC power system. AC/DC 1 charger to existing DC system.

4 Improve DC bus load shedding. Extended DC power availability during an SBO. AC/DC 1 5 Provide DC bus cross-ties. Improved availability of DC power system. AC/DC 1 6 Provide additional DC power to the 120/240V vital AC system. Increased availability of the 120 V vital AC bus. AC/DC 1 7 Add an automatic feature to transfer the 120V vital AC bus from Increased availability of the 120 V vital AC bus. AC/DC 1 normal to standby power.

8 Increase training on response to loss of two 120V AC buses which Improved chances of successful response to loss of two AC/DC 1 causes inadvertent actuation signals. 120V AC buses.

9 Provide an additional diesel generator. Increased availability of on-site emergency AC power. AC/DC 1 10 Revise procedure to allow bypass of diesel generator trips. Extended diesel generator operation. AC/DC 1 11 Improve 4.16-kV bus cross-tie ability. Increased availability of on-site AC power. AC/DC 1 12 Create AC power cross-tie capability with other unit (multi-unit site) Increased availability of on-site AC power. AC/DC 1 13 Install an additional, buried off-site power source. Reduced probability of loss of off-site power. AC/DC 1 14 Install a gas turbine generator. Increased availability of on-site AC power. AC/DC 1 15 Install tornado protection on gas turbine generator. Increased availability of on-site AC power. AC/DC 1 16 Improve uninterruptible power supplies. Increased availability of power supplies supporting front- AC/DC 1 line equipment.

17 Create a cross-tie for diesel fuel oil (multi-unit site). Increased diesel generator availability. AC/DC 1 18 Develop procedures for replenishing diesel fuel oil. Increased diesel generator availability. AC/DC 1 19 Use fire water system as a backup source for diesel cooling. Increased diesel generator availability. AC/DC 1 20 Add a new backup source of diesel cooling. Increased diesel generator availability. AC/DC 1 21 Develop procedures to repair or replace failed 4 KV breakers. Increased probability of recovery from failure of breakers AC/DC 1 that transfer 4.16 kV non-emergency buses from unit station service transformers.

22 In training, emphasize steps in recovery of off-site power after an Reduced human error probability during off-site power AC/DC 1 SBO. recovery.

23 Develop a severe weather conditions procedure. Improved off-site power recovery following external AC/DC 1 weather-related events.

24 Bury off-site power lines. Improved off-site power reliability during severe AC/DC 1 weather.

25 Install an independent active or passive high pressure injection Improved prevention of core melt sequences. Core 1 system. Cooling

ULNRC-05908 September 24, 2012 Page 3 of 58 Table 5-1. List of SAMA Candidates (Continued).

Callaway SAMA Focus of Number Potential Improvement Discussion SAMA Source 26 Provide an additional high pressure injection pump with independent Reduced frequency of core melt from small LOCA and Core 1 diesel. SBO sequences. Cooling 27 Revise procedure to allow operators to inhibit automatic vessel Extended HPCI and RCIC operation. Core 1 depressurization in non-ATWS scenarios. Cooling 28 Add a diverse low pressure injection system. Improved injection capability. Core 1 Cooling 29 Provide capability for alternate injection via diesel-driven fire pump. Improved injection capability. Core 1 Cooling 30 Improve ECCS suction strainers. Enhanced reliability of ECCS suction. Core 1 Cooling 31 Add the ability to manually align emergency core cooling system Enhanced reliability of ECCS suction. Core 1 recirculation. Cooling 32 Add the ability to automatically align emergency core cooling system Enhanced reliability of ECCS suction. Core 1 to recirculation mode upon refueling water storage tank depletion. Cooling 33 Provide hardware and procedure to refill the reactor water storage Extended reactor water storage tank capacity in the Core 1 tank once it reaches a specified low level. event of a steam generator tube rupture (or other Cooling LOCAs challenging RWST capacity).

34 Provide an in-containment reactor water storage tank. Continuous source of water to the safety injection Core 1 pumps during a LOCA event, since water released from Cooling a breach of the primary system collects in the in-containment reactor water storage tank, and thereby eliminates the need to realign the safety injection pumps for long-term post-LOCA recirculation.

35 Throttle low pressure injection pumps earlier in medium or large- Extended reactor water storage tank capacity. Core 1 break LOCAs to maintain reactor water storage tank inventory. Cooling 36 Emphasize timely recirculation alignment in operator training. Reduced human error probability associated with Core 1 recirculation failure. Cooling 37 Upgrade the chemical and volume control system to mitigate small For a plant like the Westinghouse AP600, where the Core 1 LOCAs. chemical and volume control system cannot mitigate a Cooling small LOCA, an upgrade would decrease the frequency of core damage.

ULNRC-05908 September 24, 2012 Page 4 of 58 Table 5-1. List of SAMA Candidates (Continued).

Callaway SAMA Focus of Number Potential Improvement Discussion SAMA Source 38 Change the in-containment reactor water storage tank suction from Reduced common mode failure of injection paths. Core 1 four check valves to two check and two air-operated valves. Cooling 39 Replace two of the four electric safety injection pumps with diesel- Reduced common cause failure of the safety injection Core 1 powered pumps. system. This SAMA was originally intended for the Cooling Westinghouse-CE System 80+, which has four trains of safety injection. However, the intent of this SAMA is to provide diversity within the high- and l 40 Provide capability for remote, manual operation of secondary side Improved chance of successful operation during station Core 1 pilot-operated relief valves in a station blackout. blackout events in which high area temperatures may be Cooling encountered (no ventilation to main steam areas).

41 Create a reactor coolant depressurization system. Allows low pressure emergency core cooling system Core 1 injection in the event of small LOCA and high-pressure Cooling safety injection failure.

42 Make procedure changes for reactor coolant system Allows low pressure emergency core cooling system Core 1 depressurization. injection in the event of small LOCA and high-pressure Cooling safety injection failure.

43 Add redundant DC control power for SW pumps. Increased availability of SW. Cooling 1 Water 44 Replace ECCS pump motors with air-cooled motors. Elimination of ECCS dependency on component cooling Cooling 1 system. Water 45 Enhance procedural guidance for use of cross-tied component Reduced frequency of loss of component cooling water Cooling 1 cooling or service water pumps. and service water. Water 46 Add a service water pump. Increased availability of cooling water. Cooling 1 Water 47 Enhance the screen wash system. Reduced potential for loss of SW due to clogging of Cooling 1 screens. Water 48 Cap downstream piping of normally closed component cooling water Reduced frequency of loss of component cooling water Cooling 1 drain and vent valves. initiating events, some of which can be attributed to Water catastrophic failure of one of the many single isolation valves.

49 Enhance loss of component cooling water (or loss of service water) Reduced potential for reactor coolant pump seal damage Cooling 1 procedures to facilitate stopping the reactor coolant pumps. due to pump bearing failure. Water 50 Enhance loss of component cooling water procedure to underscore Reduced probability of reactor coolant pump seal failure. Cooling 1 the desirability of cooling down the reactor coolant system prior to Water seal LOCA.

51 Additional training on loss of component cooling water. Improved success of operator actions after a loss of Cooling 1 component cooling water. Water

ULNRC-05908 September 24, 2012 Page 5 of 58 Table 5-1. List of SAMA Candidates (Continued).

Callaway SAMA Focus of Number Potential Improvement Discussion SAMA Source 52 Provide hardware connections to allow another essential raw cooling Reduced effect of loss of component cooling water by Cooling 1 water system to cool charging pump seals. providing a means to maintain the charging pump seal Water injection following a loss of normal cooling water.

53 On loss of essential raw cooling water, proceduralize shedding Increased time before loss of component cooling water Cooling 1 component cooling water loads to extend the component cooling (and reactor coolant pump seal failure) during loss of Water water heat-up time. essential raw cooling water sequences.

54 Increase charging pump lube oil capacity. Increased time before charging pump failure due to lube Cooling 1 oil overheating in loss of cooling water sequences. Water 55 Install an independent reactor coolant pump seal injection system, Reduced frequency of core damage from loss of Cooling 1 with dedicated diesel. component cooling water, service water, or station Water blackout.

56 Install an independent reactor coolant pump seal injection system, Reduced frequency of core damage from loss of Cooling 1 without dedicated diesel. component cooling water or service water, but not a Water station blackout.

57 Use existing hydro test pump for reactor coolant pump seal injection. Reduced frequency of core damage from loss of Cooling 1 component cooling water or service water, but not a Water station blackout, unless an alternate power source is used.

58 Install improved reactor coolant pump seals. Reduced likelihood of reactor coolant pump seal LOCA. Cooling 1 Water 59 Install an additional component cooling water pump. Reduced likelihood of loss of component cooling water Cooling 1 leading to a reactor coolant pump seal LOCA. Water 60 Prevent makeup pump flow diversion through the relief valves. Reduced frequency of loss of reactor coolant pump seal Cooling 1 cooling if spurious high pressure injection relief valve Water opening creates a flow diversion large enough to prevent reactor coolant pump seal injection.

61 Change procedures to isolate reactor coolant pump seal return flow Reduced frequency of core damage due to loss of seal Cooling 1 on loss of component cooling water, and provide (or enhance) cooling. Water guidance on loss of injection during seal LOCA.

62 Implement procedures to stagger high pressure safety injection Extended high pressure injection prior to overheating Cooling 1 pump use after a loss of service water. following a loss of service water. Water 63 Use fire prevention system pumps as a backup seal injection and Reduced frequency of reactor coolant pump seal LOCA. Cooling 1 high pressure makeup source. Water

ULNRC-05908 September 24, 2012 Page 6 of 58 Table 5-1. List of SAMA Candidates (Continued).

Callaway SAMA Focus of Number Potential Improvement Discussion SAMA Source 64 Implement procedure and hardware modifications to allow manual Improved ability to cool residual heat removal heat Cooling 1 alignment of the fire water system to the component cooling water exchangers. Water system, or install a component cooling water header cross-tie.

65 Install a digital feed water upgrade. Reduced chance of loss of main feed water following a Feedwater/ 1 plant trip. Condensate 66 Create ability for emergency connection of existing or new water Increased availability of feedwater. Feedwater/C 1 sources to feedwater and condensate systems. ondensate 67 Install an independent diesel for the condensate storage tank Extended inventory in CST during an SBO. Feedwater/C 1 makeup pumps. ondensate 68 Add a motor-driven feedwater pump. Increased availability of feedwater. Feedwater/C 1 ondensate 69 Install manual isolation valves around auxiliary feedwater turbine- Reduced dual turbine-driven pump maintenance Feedwater/C 1 driven steam admission valves. unavailability. ondensate 70 Install accumulators for turbine-driven auxiliary feedwater pump flow Eliminates the need for local manual action to align Feedwater/C 1 control valves. nitrogen bottles for control air following a loss of off-site ondensate power.

71 Install a new condensate storage tank (auxiliary feedwater storage Increased availability of the auxiliary feedwater system. Feedwater/C 1 tank). ondensate 72 Modify the turbine-driven auxiliary feedwater pump to be self-cooled. Improved success probability during a station blackout. Feedwater/C 1 ondensate 73 Proceduralize local manual operation of auxiliary feedwater system Extended auxiliary feedwater availability during a station Feedwater/C 1 when control power is lost. blackout. Also provides a success path should auxiliary ondensate feedwater control power be lost in non-station blackout sequences.

74 Provide hookup for portable generators to power the turbine-driven Extended auxiliary feedwater availability. Feedwater/C 1 auxiliary feedwater pump after station batteries are depleted. ondensate 75 Use fire water system as a backup for steam generator inventory. Increased availability of steam generator water supply. Feedwater/C 1 ondensate 76 Change failure position of condenser makeup valve if the condenser Allows greater inventory for the auxiliary feedwater Feedwater/C 1 makeup valve fails open on loss of air or power. pumps by preventing condensate storage tank flow ondensate diversion to the condenser.

77 Provide a passive, secondary-side heat-rejection loop consisting of a Reduced potential for core damage due to loss-of- Feedwater/C 1 condenser and heat sink. feedwater events. ondensate 78 Modify the startup feedwater pump so that it can be used as a Increased reliability of decay heat removal. Feedwater/C 1 backup to the emergency feedwater system, including during a ondensate station blackout scenario.

79 Replace existing pilot-operated relief valves with larger ones, such Increased probability of successful feed and bleed. Feedwater/C 1 that only one is required for successful feed and bleed. ondensate

ULNRC-05908 September 24, 2012 Page 7 of 58 Table 5-1. List of SAMA Candidates (Continued).

Callaway SAMA Focus of Number Potential Improvement Discussion SAMA Source 80 Provide a redundant train or means of ventilation. Increased availability of components dependent on HVAC 1 room cooling.

81 Add a diesel building high temperature alarm or redundant louver Improved diagnosis of a loss of diesel building HVAC. HVAC 1 and thermostat.

82 Stage backup fans in switchgear rooms. Increased availability of ventilation in the event of a loss HVAC 1 of switchgear ventilation.

83 Add a switchgear room high temperature alarm. Improved diagnosis of a loss of switchgear HVAC. HVAC 1 84 Create ability to switch emergency feedwater room fan power supply Continued fan operation in a station blackout. HVAC 1 to station batteries in a station blackout.

85 Provide cross-unit connection of uninterruptible compressed air Increased ability to vent containment using the IA/Nitrogen 1 supply. hardened vent.

86 Modify procedure to provide ability to align diesel power to more air Increased availability of instrument air after a LOOP. IA/Nitrogen 1 compressors.

87 Replace service and instrument air compressors with more reliable Elimination of instrument air system dependence on IA/Nitrogen 1 compressors which have self-contained air cooling by shaft driven service water cooling.

fans.

88 Install nitrogen bottles as backup gas supply for safety relief valves. Extended SRV operation time. IA/Nitrogen 1 89 Improve SRV and MSIV pneumatic components. Improved availability of SRVs and MSIVs. IA/Nitrogen 1 90 Create a reactor cavity flooding system. Enhanced debris cool ability, reduced core concrete Containment 1 interaction, and increased fission product scrubbing. Phenomena 91 Install a passive containment spray system. Improved containment spray capability. Containment 1 Phenomena 92 Use the fire water system as a backup source for the containment Improved containment spray capability. Containment 1 spray system. Phenomena 93 Install an unfiltered, hardened containment vent. Increased decay heat removal capability for non-ATWS Containment 1 events, without scrubbing released fission products. Phenomena 94 Install a filtered containment vent to remove decay heat. Option 1: Increased decay heat removal capability for non-ATWS Containment 1 Gravel Bed Filter; Option 2: Multiple Venturi Scrubber events, with scrubbing of released fission products. Phenomena 95 Enhance fire protection system and standby gas treatment system Improved fission product scrubbing in severe accidents. Containment 1 hardware and procedures. Phenomena 96 Provide post-accident containment inerting capability. Reduced likelihood of hydrogen and carbon monoxide Containment 1 gas combustion. Phenomena 97 Create a large concrete crucible with heat removal potential to Increased cooling and containment of molten core Containment 1 contain molten core debris. debris. Molten core debris escaping from the vessel is Phenomena contained within the crucible and a water cooling mechanism cools the molten core in the crucible, preventing melt-through of the base mat.

ULNRC-05908 September 24, 2012 Page 8 of 58 Table 5-1. List of SAMA Candidates (Continued).

Callaway SAMA Focus of Number Potential Improvement Discussion SAMA Source 98 Create a core melt source reduction system. Increased cooling and containment of molten core Containment 1 debris. Refractory material would be placed underneath Phenomena the reactor vessel such that a molten core falling on the material would melt and combine with the material.

Subsequent spreading and heat removal from the vitrified compound would be facilitated, and concrete attack would not occur.

99 Strengthen primary/secondary containment (e.g., add ribbing to Reduced probability of containment over-pressurization. Containment 1 containment shell). Phenomena 100 Increase depth of the concrete base mat or use an alternate Reduced probability of base mat melt-through. Containment 1 concrete material to ensure melt-through does not occur. Phenomena 101 Provide a reactor vessel exterior cooling system. Increased potential to cool a molten core before it Containment 1 causes vessel failure, by submerging the lower head in Phenomena water.

102 Construct a building to be connected to primary/secondary Reduced probability of containment over-pressurization. Containment 1 containment and maintained at a vacuum. Phenomena 103 Institute simulator training for severe accident scenarios. Improved arrest of core melt progress and prevention of Containment 1 containment failure. Phenomena 104 Improve leak detection procedures. Increased piping surveillance to identify leaks prior to Containment 1 complete failure. Improved leak detection would reduce Phenomena LOCA frequency.

105 Delay containment spray actuation after a large LOCA. Extended reactor water storage tank availability. Containment 1 Phenomena 106 Install automatic containment spray pump header throttle valves. Extended time over which water remains in the reactor Containment 1 water storage tank, when full containment spray flow is Phenomena not needed.

107 Install a redundant containment spray system. Increased containment heat removal ability. Containment 1 Phenomena 108 Install an independent power supply to the hydrogen control system Reduced hydrogen detonation potential. Containment 1 using either new batteries, a non-safety grade portable generator, Phenomena existing station batteries, or existing AC/DC independent power supplies, such as the security system diesel.

109 Install a passive hydrogen control system. Reduced hydrogen detonation potential. Containment 1 Phenomena

ULNRC-05908 September 24, 2012 Page 9 of 58 Table 5-1. List of SAMA Candidates (Continued).

Callaway SAMA Focus of Number Potential Improvement Discussion SAMA Source 110 Erect a barrier that would provide enhanced protection of the Reduced probability of containment failure. Containment 1 containment walls (shell) from ejected core debris following a core Phenomena melt scenario at high pressure.

111 Install additional pressure or leak monitoring instruments for Reduced ISLOCA frequency. Containment 1 detection of ISLOCAs. Bypass 112 Add redundant and diverse limit switches to each containment Reduced frequency of containment isolation failure and Containment 1 isolation valve. ISLOCAs. Bypass 113 Increase leak testing of valves in ISLOCA paths. Reduced ISLOCA frequency. Containment 1 Bypass 114 Install self-actuating containment isolation valves. Reduced frequency of isolation failure. Containment 1 Bypass 115 Locate residual heat removal (RHR) inside containment Reduced frequency of ISLOCA outside containment. Containment 1 Bypass 116 Ensure ISLOCA releases are scrubbed. One method is to plug Scrubbed ISLOCA releases. Containment 1 drains in potential break areas so that break point will be covered Bypass with water.

117 Revise EOPs to improve ISLOCA identification. Increased likelihood that LOCAs outside containment Containment 1 are identified as such. A plant had a scenario in which Bypass an RHR ISLOCA could direct initial leakage back to the pressurizer relief tank, giving indication that the LOCA was inside containment.

118 Improve operator training on ISLOCA coping. Decreased ISLOCA consequences. Containment 1 Bypass 119 Institute a maintenance practice to perform a 100% inspection of Reduced frequency of steam generator tube ruptures. Containment 1 steam generator tubes during each refueling outage. Bypass 120 Replace steam generators with a new design. Reduced frequency of steam generator tube ruptures. Containment 1 Bypass 121 Increase the pressure capacity of the secondary side so that a steam Eliminates release pathway to the environment following Containment 1 generator tube rupture would not cause the relief valves to lift. a steam generator tube rupture. Bypass 122 Install a redundant spray system to depressurize the primary system Enhanced depressurization capabilities during steam Containment 1 during a steam generator tube rupture generator tube rupture. Bypass 123 Proceduralize use of pressurizer vent valves during steam generator Backup method to using pressurizer sprays to reduce Containment 1 tube rupture sequences. primary system pressure following a steam generator Bypass tube rupture.

124 Provide improved instrumentation to detect steam generator tube Improved mitigation of steam generator tube ruptures. Containment 1 ruptures, such as Nitrogen-16 monitors). Bypass

ULNRC-05908 September 24, 2012 Page 10 of 58 Table 5-1. List of SAMA Candidates (Continued).

Callaway SAMA Focus of Number Potential Improvement Discussion SAMA Source 125 Route the discharge from the main steam safety valves through a Reduced consequences of a steam generator tube Containment 1 structure where a water spray would condense the steam and rupture. Bypass remove most of the fission products.

126 Install a highly reliable (closed loop) steam generator shell-side heat Reduced consequences of a steam generator tube Containment 1 removal system that relies on natural circulation and stored water rupture. Bypass sources 127 Revise emergency operating procedures to direct isolation of a Reduced consequences of a steam generator tube Containment 1 faulted steam generator. rupture. Bypass 128 Direct steam generator flooding after a steam generator tube Improved scrubbing of steam generator tube rupture Containment 1 rupture, prior to core damage. releases. Bypass 129 Vent main steam safety valves in containment. Reduced consequences of a steam generator tube Containment 1 rupture. Bypass 130 Add an independent boron injection system. Improved availability of boron injection during ATWS. ATWS 1 131 Add a system of relief valves to prevent equipment damage from Improved equipment availability after an ATWS. ATWS 1 pressure spikes during an ATWS.

132 Provide an additional control system for rod insertion (e.g., AMSAC). Improved redundancy and reduced ATWS frequency. ATWS 1 133 Install an ATWS sized filtered containment vent to remove decay Increased ability to remove reactor heat from ATWS ATWS 1 heat. events.

134 Revise procedure to bypass MSIV isolation in turbine trip ATWS Affords operators more time to perform actions. ATWS 1 scenarios. Discharge of a substantial fraction of steam to the main condenser (i.e., as opposed to into the primary containment) affords the operator more time to perform actions (e.g., SLC injection, lower water level, depressurize RPV) than if the main condenser was unavailable, resulting in lower human error probabilities.

135 Revise procedure to allow override of low pressure core injection Allows immediate control of low pressure core injection. ATWS 1 during an ATWS event. On failure of high pressure core injection and condensate, some plants direct reactor depressurization followed by five minutes of automatic low pressure core injection.

136 Install motor generator set trip breakers in control room. Reduced frequency of core damage due to an ATWS. ATWS 1 137 Provide capability to remove power from the bus powering the Decreased time required to insert control rods if the ATWS 1 control rods. reactor trip breakers fail (during a loss of feedwater ATWS which has rapid pressure excursion).

138 Improve inspection of rubber expansion joints on main condenser. Reduced frequency of internal flooding due to failure of Internal 1 circulating water system expansion joints. Flooding 139 Modify swing direction of doors separating turbine building basement Prevents flood propagation. Internal 1 from areas containing safeguards equipment. Flooding

ULNRC-05908 September 24, 2012 Page 11 of 58 Table 5-1. List of SAMA Candidates (Continued).

Callaway SAMA Focus of Number Potential Improvement Discussion SAMA Source 140 Increase seismic ruggedness of plant components. Increased availability of necessary plant equipment Seismic Risk 1 during and after seismic events.

141 Provide additional restraints for CO2 tanks. Increased availability of fire protection given a seismic Seismic Risk 1 event.

142 Replace mercury switches in fire protection system. Decreased probability of spurious fire suppression Fire Risk 1 system actuation.

143 Upgrade fire compartment barriers. Decreased consequences of a fire. Fire Risk 1 144 Install additional transfer and isolation switches. Reduced number of spurious actuations during a fire. Fire Risk 1 145 Enhance fire brigade awareness. Decreased consequences of a fire. Fire Risk 1 146 Enhance control of combustibles and ignition sources. Decreased fire frequency and consequences. Fire Risk 1 147 Install digital large break LOCA protection system. Reduced probability of a large break LOCA (a leak Other 1 before break).

148 Enhance procedures to mitigate large break LOCA. Reduced consequences of a large break LOCA. Other 1 149 Install computer aided instrumentation system to assist the operator Improved prevention of core melt sequences by making Other 1 in assessing post-accident plant status. operator actions more reliable.

150 Improve maintenance procedures. Improved prevention of core melt sequences by Other 1 increasing reliability of important equipment.

151 Increase training and operating experience feedback to improve Improved likelihood of success of operator actions taken Other 1 operator response. in response to abnormal conditions.

152 Develop procedures for transportation and nearby facility accidents. Reduced consequences of transportation and nearby Other 1 facility accidents.

153 Install secondary side guard pipes up to the main steam isolation Prevents secondary side depressurization should a Other 1 valves. steam line break occur upstream of the main steam isolation valves. Also guards against or prevents consequential multiple steam generator tube ruptures following a main steam line break event.

154 Mount or anchor the MCCs to the respective building walls. Reduces failure probability of MCCs during an IPEEE - B earthquake Seismic 155 Install shear pins (or strength bolts) in the AFW pumps. Takes up the shear load on the pump and/or driver IPEEE - B during an earthquake. Seismic 156 Mount all fire extinguishers within their UL Standard required drop Reduces the potential for the fire extinguishers to fall IPEEE - B height and remove hand-held fire extinguishers from Containment during an earthquake and potentially fracturing upon Seismic during normal operation. impact with the floor or another object.

ULNRC-05908 September 24, 2012 Page 12 of 58 Table 5-1. List of SAMA Candidates (Continued).

Callaway SAMA Focus of Number Potential Improvement Discussion SAMA Source 157 Identify and remove unsecured equipment near areas that contain Ensures direct access to areas such as Load Shedding IPEEE - B relays that actuate, so area is kept clear. and Emergency Load Sequencing (LSELS) and Seismic Engineered Safety Feature Actuation System (ESFAS) cabinets. Unsecured equipment (e.g.,

carts, filing cabinets, and test equipment) in these areas could result 158 Properly position chain hoists that facilitate maintenance on pumps Improper positioning of hoists reduces the availability IPEEE - B within pump rooms and institute a training program to ensure that the due to moving during an earthquake and having Seismic hoists are properly positioned when not in use. chainfalls impacting pump oil bubblers or other soft targets resulting in failure of the pumps.

159 Secure floor grating to prevent damage to sensing lines due to Prevent sensing lines that pass through the grating from IPEEE - B differential building motion. being damaged. Seismic 160 Modifications to lessen impact of internal flooding path through Lower impact of flood that propagates through the Internal D Control Building dumbwaiter. dumbwaiter Flooding 161 Improvements to PORV performance that will lower the probability of Decrease in risk due to PORV failing to open. Core Cooling E failure to open.

162 Install a large volume EDG fuel oil tank at an elevation greater than Allows transfer of EDF fuel oil to the EDG day tanks on AC/DC C the EDG fuel oil day tanks. failure of the fuel oil transfer pumps.

163 Improve feedwater check valve reliability to reduce probability of Lower risk due to failures in which feedwater check Cooling E failure to open. valves fail to open and allow feeding of the steam Water generators.

164 Provide the capability to power the normal service water pumps from Provide backup to ESW in conditions with power only Cooling D AEPS. available from AEPS. Water 165 Purchase or manufacture a "gagging device" that could be used to Reduce the amount of radioactive material release to SGTR C close a stuck open steam generator relief valve for a SGTR event the atmosphere in a SGTR event with core damage.

prior to core damage.

166 Installation of high temperature qualified RCP seal O-rings. Lower potential for RCP seal leakage. RCP Seal A LOCA 167 Addition of procedural guidance to re-establish normal service water Provide back-up pumps for UHS cooling. Cooling A should essential service water fail. Water 168 Addition of procedural guidance for running charging and safety Allow use of pumps following loss of component cooling Cooling A injection pumps without component cooling water water. Water 169 Addition of procedural guidance to verify RHR pump room cooling at Verifying that support system for RHR pumps is in HVAC A switchover to ECCS recirculation phase. service to allow continued operation of RHR pumps.

170 Modifications to add controls in the main control room to allow Faster ability to provide power to the plant electrical AC Power C remote operation of nearby diesel generator farm and busses from the offsite diesel generator farm.

alignment/connection to the plant vital electrical busses.

ULNRC-05908 September 24, 2012 Page 13 of 58 Table 5-1. List of SAMA Candidates (Continued).

Callaway SAMA Focus of Number Potential Improvement Discussion SAMA Source 171 Increase the size of the RWST or otherwise improve the availability Ensure a supply of makeup water is available from the Core Cooling E of the RWST RWST.

172 Addition of procedural guidance and the required hardware to enable Provide a backup to turbine driven auxiliary feedwater. Feedwater A the operators to feed one or more steam generators with a diesel driven firewater pump.

173 Addition of a black start combustion turbine generator. A redundant source of AC Power that could be used in AC Power A station blackout events.

174 Addition of a black-start engine-generator to provide AC Power Ability to power a 125VDC battery charger and a AC Power A during a station blackout charging pump. Powering the battery charger would permit operation of the TDAFP without recovering AC power. Powering a charging pump could provide RCP seal injection and preclude a RCP seal LOCA during a station blackout.

175 Replacement of the positive displacement charging pump with a third Provide another source for RCP seal cooling, RCS Cooling A centrifugal charging pump. makeup, and pumped flow for feed and bleed. Water 176 Provide control modifications to bypass feedwater isolation in order Allow faster and more reliable bypass of the main Feedwater A to restore main feedwater. feedwater isolation signal in order to restore main feedwater to the steam generators should auxiliary feedwater fail.

177 Procedural and hardware modifications to reduce core damage risk The IPE identified a need to form a task force to identify Flooding A due to internal flooding. and evaluate potential procedural and hardware modifications aimed at reducing the risk due to internal flooding.

178 Improvements to UHS cooling tower electrical room HVAC. Improve availability or mitigate loss of HVAC. HVAC E 179 Modify procedures such that the water loop seals in the RCS cold Prevents possible thermally induced steam generator Containment C legs are not cleared following core damage. tube rupture following core damage. Bypass 180 Install lower amperage fuses for various 14 AWG control circuits in Reduced fire risk. Fire Risk F the MCR. The majority of the modification centers around the trip circuit fuses on NB, NG, PA, PB, and PG system breakers.

181 Install redundant fuses and isolation switches for MCR evacuation Reduced fire risk. Fire Risk F procedure OTO-ZZ-00001.

182 To protect against multiple spurious operation scenarios, cable runs Reduced fire risk. Fire Risk F will be changed to run a single wire in a protected metal jacket such that spurious valve opening due to a hot short affecting the valve control circuit is eliminated for the fire area. This modification will be implemented in multiple fire areas.

ULNRC-05908 September 24, 2012 Page 14 of 58 Table 5-1. List of SAMA Candidates (Continued).

Callaway SAMA Focus of Number Potential Improvement Discussion SAMA Source 183 Quick response sprinkler heads in cable chases A-11, C-30, and C- Reduced fire risk. Fire Risk F 31 will be modified to be in accordance with the applicable requirements of NFPA 13-1976 edition.

184 Improvements in the reliability of the Steam Line Isolation automatic More reliable main steam line isolation. Containment E signal. Isolation 185 Automate initiation of CCW flow to the RHR heat exchangers. More reliable than manual initiation of flow to RRHR HX. Cooling E Water 186 Develop a procedure and obtain equipment to provide a temporary Backup cooling water if ESW/SW is lost Cooling D hookup of fire water as a replacement for ESW Water Note 1: The source references are:

1 NEI 05-01 (Reference 19)

A IPE (Reference 28)

B IPEEE (Reference 29)

C Recent industry SAMA submittals (Wolf Creek, South Texas, Diablo Canyon, Seabrook)

D Expert panel convened to review SAMA analysis or other plant personnel E PRA importance list review F Callaway NFPA 805 License Amendment Request

ULNRC-05908 September 24, 2012 Page 15 of 58 6.0 PHASE I ANALYSIS A preliminary screening of the complete list of SAMA candidates was performed to limit the number of SAMAs for which detailed analysis in Phase II was necessary. The screening criteria used in the Phase I analysis are described below.

  • Screening Criterion A - Not Applicable: If a SAMA candidate did not apply to the Callaway Unit 1 plant design, it was not retained.
  • Screening Criterion B - Already Implemented or Intent Met: If a SAMA candidate had already been implemented at the Callaway Plant or its intended benefit already achieved by other means, it was not retained.
  • Screening Criterion C - Combined: If a SAMA candidate was similar in nature and could be combined with another SAMA candidate to develop a more comprehensive or plant-specific SAMA candidate, only the combined SAMA candidate was retained.
  • Screening Criterion D - Excessive Implementation Cost: If a SAMA required extensive changes that will obviously exceed the maximum benefit (Section 4.5), even without an implementation cost estimate, it was not retained.
  • Screening Criterion E - Very Low Benefit: If a SAMA from an industry document was related to a non-risk significant system for which change in reliability is known to have negligible impact on the risk profile, it was not retained. (No SAMAs were screened using this criterion.)

Table 6-1 presents the list of Phase I SAMA candidates and provides the disposition of each candidate along with the applicable screening criterion associated with each candidate. Those candidates that have not been screened by application of these criteria are evaluated further in the Phase II analysis (Section 7). It can be seen from this table that 107 SAMAs were screened from the analysis during Phase 1 and that 64 SAMAs passed into the next phase of the analysis.

ULNRC-05908 September 24, 2012 Page 16 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 12 Create AC power cross-tie Increased availability of on-site AC power. Yes A - Not Applicable Callaway is a single unit site.

capability with other unit (multi-unit site) 17 Create a cross-tie for diesel fuel oil Increased diesel generator availability. Yes A - Not Applicable Callaway is a single unit site.

(multi-unit site).

27 Revise procedure to allow Extended HPCI and RCIC operation. Yes A - Not Applicable BWR item.

operators to inhibit automatic vessel depressurization in non-ATWS scenarios.

34 Provide an in-containment reactor Continuous source of water to the safety Yes A - Not Applicable Not applicable for existing water storage tank. injection pumps during a LOCA event, since designs. Insufficient room water released from a breach of the primary inside primary containment.

system collects in the in-containment reactor water storage tank, and thereby eliminates the need to realign the safety injection pumps for long-term post-LOCA recirculation.

35 Throttle low pressure injection Extended reactor water storage tank Yes A - Not Applicable Per the Callaway safety pumps earlier in medium or large- capacity. analysis, this is an break LOCAs to maintain reactor undesirable action. The water storage tank inventory. Callaway safety analysis and design calls for injection of the RWST to inside the containment as soon as possible.

38 Change the in-containment reactor Reduced common mode failure of injection Yes A - Not Applicable Callaway does not have an in-water storage tank suction from paths. containment RWST with this four check valves to two check and valve arrangement.

two air-operated valves.

47 Enhance the screen wash system. Reduced potential for loss of SW due to Yes A - Not Applicable Plant uses Ultimate Heat Sink clogging of screens. pond for cooling. UHS sized for 30 days without make-up.

River intake is only used for make-up to the UHS.

52 Provide hardware connections to Reduced effect of loss of component cooling Yes A - Not Applicable Charging pump seals do not allow another essential raw cooling water by providing a means to maintain the require external cooling, they water system to cool charging charging pump seal injection following a loss are cooled by the process pump seals. of normal cooling water. fluid.

ULNRC-05908 September 24, 2012 Page 17 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis (Continued)

Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 57 Use existing hydro test pump for Reduced frequency of core damage from Yes A - Not Applicable Callaway does not have a reactor coolant pump seal injection. loss of component cooling water or service permanently installed hydro water, but not a station blackout, unless an test pump. Timing alternate power source is used. considerations prevent credit for hookup of temporary pump.

63 Use fire prevention system pumps Reduced frequency of reactor coolant pump Yes A - Not Applicable Existing fire protection system as a backup seal injection and high seal LOCA. pumps do not have sufficient pressure makeup source. discharge head to use as high pressure makeup source.

69 Install manual isolation valves Reduced dual turbine-driven pump Yes A - Not Applicable Callaway does not have dual around auxiliary feedwater turbine- maintenance unavailability. turbine AFW pump.

driven steam admission valves.

85 Provide cross-unit connection of Increased ability to vent containment using Yes A - Not Applicable N/A, single unit.

uninterruptible compressed air the hardened vent.

supply.

95 Enhance fire protection system and Improved fission product scrubbing in severe Yes A - Not Applicable Standby gas treatment system standby gas treatment system accidents. is BWR item.

hardware and procedures.

105 Delay containment spray actuation Extended reactor water storage tank Yes A - Not Applicable Per the Callaway safety after a large LOCA. availability. analysis, this is an undesirable action. The Callaway safety analysis and design calls for injection of the RWST to inside the containment as soon as possible.

106 Install automatic containment spray Extended time over which water remains in Yes A - Not Applicable Per the Callaway safety pump header throttle valves. the reactor water storage tank, when full analysis, this is an containment spray flow is not needed. undesirable action. The Callaway safety analysis and design calls for injection of the RWST to inside the containment as soon as possible.

ULNRC-05908 September 24, 2012 Page 18 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis (Continued)

Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 134 Revise procedure to bypass MSIV Affords operators more time to perform Yes A - Not Applicable Specific to BWRs.

isolation in turbine trip ATWS actions. Discharge of a substantial fraction of scenarios. steam to the main condenser (i.e., as opposed to into the primary containment) affords the operator more time to perform actions (e.g., SLC injection, lower water level, depressurize RPV) than if the main condenser was unavailable, resulting in lower human error probabilities.

135 Revise procedure to allow override Allows immediate control of low pressure Yes A - Not Applicable Based on description, this is a of low pressure core injection core injection. On failure of high pressure BWR item.

during an ATWS event. core injection and condensate, some plants direct reactor depressurization followed by five minutes of automatic low pressure core injection.

138 Improve inspection of rubber Reduced frequency of internal flooding due to Yes A - Not Applicable No risk significant flooding expansion joints on main failure of circulating water system expansion sources identified in the condenser. joints. turbine building.

139 Modify swing direction of doors Prevents flood propagation. Yes A - Not Applicable Flooding analysis did not separating turbine building indicate any flooding issues basement from areas containing related to the direction of door safeguards equipment. swing.

142 Replace mercury switches in fire Decreased probability of spurious fire Yes A - Not Applicable No mercury switches in the protection system. suppression system actuation. fire protection system.

143 Upgrade fire compartment barriers. Decreased consequences of a fire. Yes A - Not Applicable Fire analysis did not identify any issues related to fire barriers. NFPA 805 Fire Protection Program is in progress, any issues identified by that project will be handled by the NFPA 805 program.

152 Develop procedures for Reduced consequences of transportation and Yes A - Not Applicable IPEEE determined that there transportation and nearby facility nearby facility accidents. are no transportation routes or accidents. nearby facilities that could cause concern.

ULNRC-05908 September 24, 2012 Page 19 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis (Continued)

Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 165 Purchase or manufacture a Reduce the amount of radioactive material Yes A - Not Applicable Callaway does not have the "gagging device" that could be release to the atmosphere in a SGTR event ability to isolate the steam used to close a stuck open steam with core damage. generator from the RCS loop.

generator relief valve for a SGTR The amount of force required event prior to core damage. to close a stuck open atmospheric steam dump valve would likely not be successful and would result in further damage to the valve.

3 Add additional battery charger or Improved availability of DC power system. Yes B - Intent Met Current configuration is two portable, diesel-driven battery spare battery chargers for the charger to existing DC system. instrument buses. The spare can carry one bus. One feeds A/B, the other feeds C/D trains. Also Emergency Coordinator Supplemental Guidelines, Attachment N, "Temporary Power to NK Swing Charger 4 Improve DC bus load shedding. Extended DC power availability during an Yes B - Intent Met DC load shedding is SBO. conducted.

6 Provide additional DC power to the Increased availability of the 120 V vital AC Yes B - Intent Met Procedures in place to provide 120/240V vital AC system. bus. temporary power to DC Chargers which can power vital AC system.

7 Add an automatic feature to Increased availability of the 120 V vital AC Yes B - Intent Met On loss of DC or inverter, the transfer the 120V vital AC bus from bus. UPS static switch normal to standby power. automatically transfers to AC power through a constant voltage transformer. An additional backup AC source is available, but must be closed manually.

8 Increase training on response to Improved chances of successful response to Yes B - Intent Met Typical response training in loss of two 120V AC buses which loss of two 120V AC buses. place.

causes inadvertent actuation signals.

9 Provide an additional diesel Increased availability of on-site emergency Yes B - Intent Met Alternate Emergency Power generator. AC power. System installed.

ULNRC-05908 September 24, 2012 Page 20 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis (Continued)

Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 10 Revise procedure to allow bypass Extended diesel generator operation. Yes B - Intent Met Bypass of non-vital diesel of diesel generator trips. generator trips were in original design for Callaway.

13 Install an additional, buried off-site Reduced probability of loss of off-site power. Yes B - Intent Met AEPS installed with buried power source. power lines.

14 Install a gas turbine generator. Increased availability of on-site AC power. Yes B - Intent Met Alternate Emergency Power System installed.

16 Improve uninterruptible power Increased availability of power supplies Yes B - Intent Met Replaced to add static switch supplies. supporting front-line equipment. and upgrade to newer design.

18 Develop procedures for Increased diesel generator availability. Yes B - Intent Met EOP Addenda direct ordering replenishing diesel fuel oil. fuel oil.

19 Use fire water system as a backup Increased diesel generator availability. Yes B - Intent Met Procedures exist for cooling source for diesel cooling. EDG with fire water.

20 Add a new backup source of diesel Increased diesel generator availability. Yes B - Intent Met Procedure exists for backup cooling. diesel cooling.

21 Develop procedures to repair or Increased probability of recovery from failure Yes B - Intent Met Spares exist and procedures replace failed 4 KV breakers. of breakers that transfer 4.16 kV non- exist.

emergency buses from unit station service transformers.

22 In training, emphasize steps in Reduced human error probability during off- Yes B - Intent Met Recovery stressed in training.

recovery of off-site power after an site power recovery.

SBO.

23 Develop a severe weather Improved off-site power recovery following Yes B - Intent Met Severe weather condition conditions procedure. external weather-related events. procedure in place.

30 Improve ECCS suction strainers. Enhanced reliability of ECCS suction. Yes B - Intent Met Callaway has implemented a containment sump modification that now uses state-of-the-art strainers to address the industrys concerns on blockage from debris. This modification occurred over two outages in 2007 and 2008.

31 Add the ability to manually align Enhanced reliability of ECCS suction. Yes B - Intent Met Current alignment capabilities emergency core cooling system are half and half recirculation. (manual/automatic).

ULNRC-05908 September 24, 2012 Page 21 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis (Continued)

Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 32 Add the ability to automatically Enhanced reliability of ECCS suction. Yes B - Intent Met Current alignment capabilities align emergency core cooling are half and half system to recirculation mode upon (manual/automatic).

refueling water storage tank depletion.

33 Provide hardware and procedure to Extended reactor water storage tank capacity Yes B - Intent Met Addressed in SAMGs and the refill the reactor water storage tank in the event of a steam generator tube EC Supplemental Guideline.

once it reaches a specified low rupture (or other LOCAs challenging RWST level. capacity).

36 Emphasize timely recirculation Reduced human error probability associated Yes B - Intent Met Current alignment capabilities alignment in operator training. with recirculation failure. are half and half (manual/automatic). Swap to recirculation is stressed in operator training.

37 Upgrade the chemical and volume For a plant like the Westinghouse AP600, Yes B - Intent Met CVCS system is capable of control system to mitigate small where the chemical and volume control mitigating small LOCA.

LOCAs. system cannot mitigate a small LOCA, an upgrade would decrease the frequency of core damage.

40 Provide capability for remote, Improved chance of successful operation Yes B - Intent Met Remote Operation of manual operation of secondary side during station blackout events in which high Atmospheric Steam Dumps pilot-operated relief valves in a area temperatures may be encountered (no (ASDs) is possible.

station blackout. ventilation to main stream areas). Equipment Operators trained and Operator Aid posted.

42 Make procedure changes for Allows low pressure emergency core cooling Yes B - Intent Met Multiple depressurization reactor coolant system system injection in the event of small LOCA methods are in place.

depressurization. and high-pressure safety injection failure.

44 Replace ECCS pump motors with Elimination of ECCS dependency on Yes B - Intent Met Current ECCS pump motors air-cooled motors. component cooling system. are air-cooled. Additionally the plant OTN procedures allow for alternate trains to supply cooling.

45 Enhance procedural guidance for Reduced frequency of loss of component Yes B - Intent Met Can use service water as use of cross-tied component cooling water and service water. backup to ESW.

cooling or service water pumps.

48 Cap downstream piping of normally Reduced frequency of loss of component Yes B - Intent Met Vents & drains capped.

closed component cooling water cooling water initiating events, some of which drain and vent valves. can be attributed to catastrophic failure of one of the many single isolation valves.

ULNRC-05908 September 24, 2012 Page 22 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis (Continued)

Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 49 Enhance loss of component cooling Reduced potential for reactor coolant pump Yes B - Intent Met CCW is cooled by ESW.

water (or loss of service water) seal damage due to pump bearing failure. Currently authorized to run 10 procedures to facilitate stopping the minutes.

reactor coolant pumps.

50 Enhance loss of component cooling Reduced probability of reactor coolant pump Yes B - Intent Met Procedures include direction water procedure to underscore the seal failure. to cool down to minimize desirability of cooling down the impact of RCP seal LOCA.

reactor coolant system prior to seal LOCA.

51 Additional training on loss of Improved success of operator actions after a Yes B - Intent Met Training is conducted for Loss component cooling water. loss of component cooling water. of CCW.

53 On loss of essential raw cooling Increased time before loss of component Yes B - Intent Met Most non-safety loads have water, proceduralize shedding cooling water (and reactor coolant pump seal been removed from the component cooling water loads to failure) during loss of essential raw cooling system. Non-safety loop is extend the component cooling water sequences. automatically isolated on water heat-up time. safety injection signal.

60 Prevent makeup pump flow Reduced frequency of loss of reactor coolant Yes B - Intent Met Current configuration does not diversion through the relief valves. pump seal cooling if spurious high pressure have a relief valve.

injection relief valve opening creates a flow diversion large enough to prevent reactor coolant pump seal injection.

61 Change procedures to isolate Reduced frequency of core damage due to Yes B - Intent Met Procedure exist reactor coolant pump seal return loss of seal cooling.

flow on loss of component cooling water, and provide (or enhance) guidance on loss of injection during seal LOCA.

62 Implement procedures to stagger Extended high pressure injection prior to Yes B - Intent Met Procedure currently in place high pressure safety injection pump overheating following a loss of service water. to stagger use of HPSI.

use after a loss of service water.

66 Create ability for emergency Increased availability of feedwater. Yes B - Intent Met Procedures exist.

connection of existing or new water sources to feedwater and condensate systems.

67 Install an independent diesel for the Extended inventory in CST during an SBO. Yes B - Intent Met Procedures do exist for make-condensate storage tank makeup up to CST from fire water and pumps. for supplying fire water directly to the TDAFW pump.

ULNRC-05908 September 24, 2012 Page 23 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis (Continued)

Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 68 Add a motor-driven feedwater Increased availability of feedwater. Yes B - Intent Met Non-Safety Auxiliary pump. Feedwater Pump installed.

70 Install accumulators for turbine- Eliminates the need for local manual action to Yes B - Intent Met Currently have nitrogen driven auxiliary feedwater pump align nitrogen bottles for control air following accumulators.

flow control valves. a loss of off-site power.

72 Modify the turbine-driven auxiliary Improved success probability during a station Yes B - Intent Met Turbine-driven auxiliary feedwater pump to be self-cooled. blackout. feedwater pump is self-cooled.

73 Proceduralize local manual Extended auxiliary feedwater availability Yes B - Intent Met Procedures exist.

operation of auxiliary feedwater during a station blackout. Also provides a system when control power is lost. success path should auxiliary feedwater control power be lost in non-station blackout sequences.

74 Provide hookup for portable Extended auxiliary feedwater availability. Yes B - Intent Met Procedures exist, hardware generators to power the turbine- on site.

driven auxiliary feedwater pump after station batteries are depleted.

75 Use fire water system as a backup Increased availability of steam generator Yes B - Intent Met Equipment staged at CST for for steam generator inventory. water supply. makeup.

See operator aids.

Procedural guidance exists.

76 Change failure position of Allows greater inventory for the auxiliary Yes B - Intent Met Valve currently fails closed.

condenser makeup valve if the feedwater pumps by preventing condensate condenser makeup valve fails open storage tank flow diversion to the condenser.

on loss of air or power.

78 Modify the startup feedwater pump Increased reliability of decay heat removal. Yes B - Intent Met Non-Safety Auxiliary so that it can be used as a backup Feedwater Pump gets power to the emergency feedwater from Alternate Emergency system, including during a station Power System.

blackout scenario.

81 Add a diesel building high Improved diagnosis of a loss of diesel Yes B - Intent Met Computer points for temperature alarm or redundant building HVAC. monitoring diesel room louver and thermostat. temperatures.

82 Stage backup fans in switchgear Increased availability of ventilation in the Yes B - Intent Met Procedures include rooms. event of a loss of switchgear ventilation. instructions for opening doors to provide alternate cooling capability.

ULNRC-05908 September 24, 2012 Page 24 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis (Continued)

Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 83 Add a switchgear room high Improved diagnosis of a loss of switchgear Yes B - Intent Met Plant Process Computer has temperature alarm. HVAC. alarming computer points for switchgear room temperature.

84 Create ability to switch emergency Continued fan operation in a station blackout. Yes B - Intent Met Procedure currently in place feedwater room fan power supply to switch fan power supply.

to station batteries in a station blackout.

86 Modify procedure to provide ability Increased availability of instrument air after a Yes B - Intent Met Currently have 3 air to align diesel power to more air LOOP. compressors (service air).

compressors. A/B compressors are powered off the emergency buses (cooled from essential service lines). Compressors are initially load shed, but procedure direct operators to override and place compressor in service.

88 Install nitrogen bottles as backup Extended SRV operation time. Yes B - Intent Met Current configuration includes gas supply for safety relief valves. nitrogen bottles as backup gas supply.

89 Improve SRV and MSIV pneumatic Improved availability of SRVs and MSIVs. Yes B - Intent Met MSIV actuators changed to components. process fluid actuated.

Modification installed to relocate Atmospheric Steam Dump valve controllers.

90 Create a reactor cavity flooding Enhanced debris cool ability, reduced core Yes B - Intent Met Procedures exist system. concrete interaction, and increased fission product scrubbing.

92 Use the fire water system as a Improved containment spray capability. Yes B - Intent Met Procedures exist backup source for the containment spray system.

101 Provide a reactor vessel exterior Increased potential to cool a molten core Yes B - Intent Met Procedures exist.

cooling system. before it causes vessel failure, by submerging the lower head in water.

103 Institute simulator training for Improved arrest of core melt progress and Yes B - Intent Met Operators are trained on the severe accident scenarios. prevention of containment failure. SAMG that the operators must implement.

ULNRC-05908 September 24, 2012 Page 25 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis (Continued)

Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 117 Revise EOPs to improve ISLOCA Increased likelihood that LOCAs outside Yes B - Intent Met Current EOPs address identification. containment are identified as such. A plant ISLOCA identification.

had a scenario in which an RHR ISLOCA could direct initial leakage back to the pressurizer relief tank, giving indication that the LOCA was inside containment.

118 Improve operator training on Decreased ISLOCA consequences. Yes B - Intent Met Current procedure training ISLOCA coping. addresses ISLOCA identification.

120 Replace steam generators with a Reduced frequency of steam generator tube Yes B - Intent Met Replaced during the fall of new design. ruptures. 2005 (newer design) which consist of 72,000 sq. ft. per generator.

123 Proceduralize use of pressurizer Backup method to using pressurizer sprays Yes B - Intent Met Procedure currently in place.

vent valves during steam generator to reduce primary system pressure following tube rupture sequences. a steam generator tube rupture.

124 Provide improved instrumentation Improved mitigation of steam generator tube Yes B - Intent Met Modification installed to to detect steam generator tube ruptures. improve operation of N16 ruptures, such as Nitrogen-16 detectors.

monitors).

127 Revise emergency operating Reduced consequences of a steam Yes B - Intent Met EOP currently in place.

procedures to direct isolation of a generator tube rupture.

faulted steam generator.

128 Direct steam generator flooding Improved scrubbing of steam generator tube Yes B - Intent Met Procedures direct that steam after a steam generator tube rupture releases. generator level be maintained rupture, prior to core damage. above the tubes.

132 Provide an additional control Improved redundancy and reduced ATWS Yes B - Intent Met Currently have AMSAC.

system for rod insertion (e.g., frequency.

AMSAC).

137 Provide capability to remove power Decreased time required to insert control Yes B - Intent Met Response procedure in place.

from the bus powering the control rods if the reactor trip breakers fail (during a rods. loss of feedwater ATWS which has rapid pressure excursion).

ULNRC-05908 September 24, 2012 Page 26 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis (Continued)

Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 144 Install additional transfer and Reduced number of spurious actuations Yes B - Intent Met Items are identified and are isolation switches. during a fire. being implemented as part of the 805 process.

Examples include fuse and alternate feed line modifications to prevent the loss of the 4160 V buses.

145 Enhance fire brigade awareness. Decreased consequences of a fire. Yes B - Intent Met Most recent inspections and evaluations did not identify any weaknesses in this area.

146 Enhance control of combustibles Decreased fire frequency and consequences. Yes B - Intent Met Procedure in place. NFPA-and ignition sources. 805 project will evaluate the needs for any additional controls.

148 Enhance procedures to mitigate Reduced consequences of a large break Yes B - Intent Met Existing procedures meet large break LOCA. LOCA. current guidelines issued by the Owner's Group.

149 Install computer aided Improved prevention of core melt sequences Yes B - Intent Met Currently have SPDS in place.

instrumentation system to assist by making operator actions more reliable.

the operator in assessing post-accident plant status.

150 Improve maintenance procedures. Improved prevention of core melt sequences Yes B - Intent Met Current procedures are in line by increasing reliability of important with industry guidelines and equipment. practices.

151 Increase training and operating Improved likelihood of success of operator Yes B - Intent Met Current training program experience feedback to improve actions taken in response to abnormal meets industry standards and operator response. conditions. practices.

154 Mount or anchor the MCCs to the Reduces failure probability of MCCs during Yes B - Intent Met Identified in the IPEEE and respective building walls. an earthquake successfully implemented.

155 Install shear pins (or strength bolts) Takes up the shear load on the pump and/or Yes B - Intent Met Identified in the IPEEE and in the AFW pumps. driver during an earthquake. successfully implemented.

156 Mount all fire extinguishers within Reduces the potential for the fire Yes B - Intent Met Identified in the IPEEE and their UL Standard required drop extinguishers to fall during an earthquake successfully implemented.

height and remove hand-held fire and potentially fracturing upon impact with extinguishers from Containment the floor or another object.

during normal operation.

ULNRC-05908 September 24, 2012 Page 27 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis (Continued)

Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 157 Identify and remove unsecured Ensures direct access to areas such as Load Yes B - Intent Met Identified in the IPEEE and equipment near areas that contain Shedding and Emergency Load Sequencing successfully implemented.

relays that actuate, so area is kept (LSELS) and Engineered Safety Feature clear. Actuation System (ESFAS) cabinets. Unsecured equipment (e.g., carts, filing cabinets, and test equipment) in these areas could result 158 Properly position chain hoists that Improper positioning of hoists reduces the Yes B - Intent Met Identified in the IPEEE and facilitate maintenance on pumps availability due to moving during an successfully implemented.

within pump rooms and institute a earthquake and having chainfalls impacting training program to ensure that the pump oil bubblers or other soft targets hoists are properly positioned when resulting in failure of the pumps.

not in use.

159 Secure floor grating to prevent Prevent sensing lines that pass through the Yes B - Intent Met Identified in the IPEEE and damage to sensing lines due to grating from being damaged. successfully implemented.

differential building motion.

166 Installation of high temperature Lower potential for RCP seal leakage. Yes B - Intent Met High temperature O-Rings qualified RCP seal O-rings. installed.

167 Addition of procedural guidance to Provide back-up pumps for UHS cooling. Yes B - Intent Met Procedures in place.

re-establish normal service water should essential service water fail.

168 Addition of procedural guidance for Allow use of pumps following loss of Yes B - Intent Met Procedures in place.

running charging and safety component cooling water.

injection pumps without component cooling water 169 Addition of procedural guidance to Verifying that support system for RHR pumps Yes B - Intent Met Procedures in place.

verify RHR pump room cooling at is in service to allow continued operation of switchover to ECCS recirculation RHR pumps.

phase.

170 Modifications to add controls in the Faster ability to provide power to the plant Yes B - Intent Met AEPS diesel generators main control room to allow remote electrical busses from the offsite diesel automatically start upon loss operation of nearby diesel generator farm. of offsite power to the local generator farm and electrical co-op distribution alignment/connection to the plant system. The controls for the vital electrical busses. breakers to connect to the Callaway distribution system are in the main control room.

ULNRC-05908 September 24, 2012 Page 28 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis (Continued)

Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 172 Addition of procedural guidance Provide a backup to turbine driven auxiliary Yes B - Intent Met Procedure and hardware and the required hardware to feedwater. changes complete enable the operators to feed one or more steam generators with a diesel driven firewater pump.

173 Addition of a black start combustion A redundant source of AC Power that could Yes B - Intent Met The original evaluation of this turbine generator. be used in station blackout events. proposed modification concluded that the cost for this modification was prohibitively high. However, this was subsequently changed and the offsite Alternate Emergency Power System (AEPS) system was installed. The AEPS system consists of diesel generators and a connection to the offsite electrical Co-op.

174 Addition of a black-start engine- Ability to power a 125VDC battery charger Yes B - Intent Met The original evaluation of this generator to provide AC Power and a charging pump. Powering the battery proposed modification during a station blackout charger would permit operation of the TDAFP concluded that the cost for without recovering AC power. Powering a this modification was charging pump could provide RCP seal prohibitively high. However, injection and preclude a RCP seal LOCA later implementation of the during a station blackout. AEPS system provides the backup power source represented by this item. Also the EC Coordinator Supplemental Guidelines provide procedures and equipment for hookup of a portable generator.

175 Replacement of the positive Provide another source for RCP seal cooling, Yes B - Intent Met The positive displacement displacement charging pump with a RCS makeup, and pumped flow for feed and charging pump has been third centrifugal charging pump. bleed. replaced by a centrifugal pump that does not require component cooling water. It is powered from a non-safety 4160 VAC power supply.

ULNRC-05908 September 24, 2012 Page 29 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis (Continued)

Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 176 Provide control modifications to Allow faster and more reliable bypass of the Yes B - Intent Met Feedwater Isolation bypass bypass feedwater isolation in order main feedwater isolation signal in order to switches installed and EOP in to restore main feedwater. restore main feedwater to the steam place with directions for use.

generators should auxiliary feedwater fail.

177 Procedural and hardware The IPE identified a need to form a task force Yes B - Intent Met The flooding task force modifications to reduce core to identify and evaluate potential procedural identified 3 generic damage risk due to internal and hardware modifications aimed at recommendations; 1) evaluate flooding. reducing the risk due to internal flooding. the impact of the normal charging pump (NCP), 2) evaluate the impact of increased inspections or changes in pipe class on pipe failure probability, and 3) re-analyze pipe break flowrates for actual flow, rather than assuming pump runout flowrates. All three recommendations have been implemented. The flooding analysis credited the NCP and reduced one flood zone below the screening value. A leakage detection program was implemented which uses security personnel and operators to visually inspect specific piping in the major flood zones. The implementation of the leakage detection program reduced flooding risk sufficiently to not require the installation of some watertight doors and piping encapsulation.

140 Increase seismic ruggedness of Increased availability of necessary plant Yes C - Combined Individual seismic issues plant components. equipment during and after seismic events. identified in the IPEEE are included as SAMA items 154, 155, 156, 157, 158, and 159.

ULNRC-05908 September 24, 2012 Page 30 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis (Continued)

Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 141 Provide additional restraints for Increased availability of fire protection given Yes C - Combined Individual seismic issues CO2 tanks. a seismic event. identified in the IPEEE are included as SAMA items 154, 155, 156, 157, 158, and 159.

1 Provide additional DC battery Extended DC power availability during an No Original battery capacity is 4 capacity. SBO. hrs. No additional battery capacity has been added.

Evaluate in Phase II.

2 Replace lead-acid batteries with Extended DC power availability during an No Plant currently uses batteries fuel cells. SBO. rather than fuel cells.

Evaluate in Phase II.

5 Provide DC bus cross-ties. Improved availability of DC power system. No No existing capability for DC bus cross-ties. Evaluate in Phase II.

11 Improve 4.16-kV bus cross-tie Increased availability of on-site AC power. No Evaluate during Phase II ability.

15 Install tornado protection on gas Increased availability of on-site AC power. No No gas turbine currently turbine generator. installed. No tornado protection for Alternate Emergency Power System diesel generators. Evaluate in Phase II.

24 Bury off-site power lines. Improved off-site power reliability during No Evaluate during Phase II severe weather.

25 Install an independent active or Improved prevention of core melt sequences. No Evaluate during Phase II passive high pressure injection system.

26 Provide an additional high pressure Reduced frequency of core melt from small No Evaluate during Phase II injection pump with independent LOCA and SBO sequences.

diesel.

28 Add a diverse low pressure Improved injection capability. No Evaluate during Phase II injection system.

ULNRC-05908 September 24, 2012 Page 31 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis (Continued)

Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 29 Provide capability for alternate Improved injection capability. No Currently being evaluated by injection via diesel-driven fire plant improvement program.

pump. Would use unborated water and portable pump (fire truck).

Calculation of specific benefit of this SAMA was not performed since it is judged to be potentially low cost.

Evaluation will consider impacts of injection of non-borated water.

39 Replace two of the four electric Reduced common cause failure of the safety No Evaluate during Phase II safety injection pumps with diesel- injection system. This SAMA was originally powered pumps. intended for the Westinghouse-CE System 80+, which has four trains of safety injection.

However, the intent of this SAMA is to provide diversity within the high- and l 41 Create a reactor coolant Allows low pressure emergency core cooling No Evaluate during Phase II depressurization system. system injection in the event of small LOCA and high-pressure safety injection failure.

43 Add redundant DC control power Increased availability of SW. No Evaluate during Phase II for SW pumps.

46 Add a service water pump. Increased availability of cooling water. No Evaluate during Phase II 54 Increase charging pump lube oil Increased time before charging pump failure No Evaluate during Phase II capacity. due to lube oil overheating in loss of cooling water sequences.

55 Install an independent reactor Reduced frequency of core damage from No Evaluate during Phase II coolant pump seal injection system, loss of component cooling water, service with dedicated diesel. water, or station blackout.

56 Install an independent reactor Reduced frequency of core damage from No Evaluate during Phase II coolant pump seal injection system, loss of component cooling water or service without dedicated diesel. water, but not a station blackout.

58 Install improved reactor coolant Reduced likelihood of reactor coolant pump No Evaluate during Phase II pump seals. seal LOCA.

59 Install an additional component Reduced likelihood of loss of component No Evaluate during Phase II cooling water pump. cooling water leading to a reactor coolant pump seal LOCA.

ULNRC-05908 September 24, 2012 Page 32 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis (Continued)

Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 64 Implement procedure and hardware Improved ability to cool residual heat removal No Evaluate during Phase II modifications to allow manual heat exchangers.

alignment of the fire water system to the component cooling water system, or install a component cooling water header cross-tie.

65 Install a digital feed water upgrade. Reduced chance of loss of main feed water No Evaluate during Phase II following a plant trip.

71 Install a new condensate storage Increased availability of the auxiliary No Evaluate during Phase II tank (auxiliary feedwater storage feedwater system.

tank).

77 Provide a passive, secondary-side Reduced potential for core damage due to No Evaluate during Phase II heat-rejection loop consisting of a loss-of-feedwater events.

condenser and heat sink.

79 Replace existing pilot-operated Increased probability of successful feed and No Evaluate during Phase II relief valves with larger ones, such bleed.

that only one is required for successful feed and bleed.

80 Provide a redundant train or means Increased availability of components No Evaluate during Phase II of ventilation. dependent on room cooling.

87 Replace service and instrument air Elimination of instrument air system No Air compressors currently compressors with more reliable dependence on service water cooling. cooled by ESW. Evaluate compressors which have self- during Phase II contained air cooling by shaft driven fans.

91 Install a passive containment spray Improved containment spray capability. No Evaluate during Phase II system.

93 Install an unfiltered, hardened Increased decay heat removal capability for No Evaluate during Phase II containment vent. non-ATWS events, without scrubbing released fission products.

94 Install a filtered containment vent to Increased decay heat removal capability for No Evaluate during Phase II remove decay heat. Option 1: non-ATWS events, with scrubbing of Gravel Bed Filter; Option 2: released fission products.

Multiple Venturi Scrubber 96 Provide post-accident containment Reduced likelihood of hydrogen and carbon No Evaluate during Phase II inerting capability. monoxide gas combustion.

ULNRC-05908 September 24, 2012 Page 33 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis (Continued)

Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 97 Create a large concrete crucible Increased cooling and containment of molten No Evaluate during Phase II with heat removal potential to core debris. Molten core debris escaping contain molten core debris. from the vessel is contained within the crucible and a water cooling mechanism cools the molten core in the crucible, preventing melt-through of the base mat.

98 Create a core melt source Increased cooling and containment of molten No Evaluate during Phase II reduction system. core debris. Refractory material would be placed underneath the reactor vessel such that a molten core falling on the material would melt and combine with the material.

Subsequent spreading and heat removal from the vitrified compound would be facilitated, and concrete attack would not occur.

99 Strengthen primary/secondary Reduced probability of containment over- No Evaluate during Phase II containment (e.g., add ribbing to pressurization.

containment shell).

100 Increase depth of the concrete Reduced probability of base mat melt- No Evaluate during Phase II base mat or use an alternate through.

concrete material to ensure melt-through does not occur.

102 Construct a building to be Reduced probability of containment over- No Evaluate during Phase II connected to primary/secondary pressurization.

containment and maintained at a vacuum.

104 Improve leak detection procedures. Increased piping surveillance to identify leaks No Evaluate during Phase II prior to complete failure. Improved leak detection would reduce LOCA frequency.

107 Install a redundant containment Increased containment heat removal ability. No Evaluate during Phase II spray system.

ULNRC-05908 September 24, 2012 Page 34 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis (Continued)

Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 108 Install an independent power Reduced hydrogen detonation potential. No Evaluate during Phase II supply to the hydrogen control system using either new batteries, a non-safety grade portable generator, existing station batteries, or existing AC/DC independent power supplies, such as the security system diesel.

109 Install a passive hydrogen control Reduced hydrogen detonation potential. No Evaluate during Phase II system.

110 Erect a barrier that would provide Reduced probability of containment failure. No Evaluate during Phase II enhanced protection of the containment walls (shell) from ejected core debris following a core melt scenario at high pressure.

111 Install additional pressure or leak Reduced ISLOCA frequency. No Evaluate during Phase II monitoring instruments for detection of ISLOCAs.

112 Add redundant and diverse limit Reduced frequency of containment isolation No Evaluate during Phase II switches to each containment failure and ISLOCAs.

isolation valve.

113 Increase leak testing of valves in Reduced ISLOCA frequency. No Evaluate during Phase II ISLOCA paths.

114 Install self-actuating containment Reduced frequency of isolation failure. No Evaluate during Phase II isolation valves.

115 Locate residual heat removal Reduced frequency of ISLOCA outside No Evaluate during Phase II (RHR) inside containment containment.

116 Ensure ISLOCA releases are Scrubbed ISLOCA releases. No Evaluate during Phase II scrubbed. One method is to plug drains in potential break areas so that break point will be covered with water.

119 Institute a maintenance practice to Reduced frequency of steam generator tube No Current frequency of perform a 100% inspection of ruptures. inspection of SG tubes is steam generator tubes during each 100% inspection every third refueling outage. outage.

Evaluate during Phase II

ULNRC-05908 September 24, 2012 Page 35 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis (Continued)

Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 121 Increase the pressure capacity of Eliminates release pathway to the No Evaluate during Phase II the secondary side so that a steam environment following a steam generator generator tube rupture would not tube rupture.

cause the relief valves to lift.

122 Install a redundant spray system to Enhanced depressurization capabilities No Evaluate during Phase II depressurize the primary system during steam generator tube rupture.

during a steam generator tube rupture 125 Route the discharge from the main Reduced consequences of a steam No Evaluate during Phase II steam safety valves through a generator tube rupture.

structure where a water spray would condense the steam and remove most of the fission products.

126 Install a highly reliable (closed loop) Reduced consequences of a steam No Evaluate during Phase II steam generator shell-side heat generator tube rupture.

removal system that relies on natural circulation and stored water sources 129 Vent main steam safety valves in Reduced consequences of a steam No Evaluate during Phase II containment. generator tube rupture.

130 Add an independent boron injection Improved availability of boron injection during No Evaluate during Phase II system. ATWS.

131 Add a system of relief valves to Improved equipment availability after an No Evaluate during Phase II prevent equipment damage from ATWS.

pressure spikes during an ATWS.

133 Install an ATWS sized filtered Increased ability to remove reactor heat from No Evaluate during Phase II containment vent to remove decay ATWS events.

heat.

136 Install motor generator set trip Reduced frequency of core damage due to No Evaluate during Phase II breakers in control room. an ATWS.

147 Install digital large break LOCA Reduced probability of a large break LOCA No Evaluate during Phase II protection system. (a leak before break).

153 Install secondary side guard pipes Prevents secondary side depressurization No Evaluate during Phase II up to the main steam isolation should a steam line break occur upstream of valves. the main steam isolation valves. Also guards against or prevents consequential multiple steam generator tube ruptures following a main steam line break event.

ULNRC-05908 September 24, 2012 Page 36 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis (Continued)

Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 160 Modifications to lessen impact of Lower impact of flood that propagates No Evaluate during Phase II internal flooding path through through the dumbwaiter Control Building dumbwaiter.

161 Improvements to PORV Decrease in risk due to PORV failing to open. No Evaluate during Phase II performance that will lower the probability of failure to open.

162 Install a large volume EDG fuel oil Allows transfer of EDF fuel oil to the EDG No Evaluate during Phase II tank at an elevation greater than day tanks on failure of the fuel oil transfer the EDG fuel oil day tanks. pumps.

163 Improve feedwater check valve Lower risk due to failures in which feedwater No Valves replaced with new reliability to reduce probability of check valves fail to open and allow feeding of type, but are still significant failure to open. the steam generators. risk contributor. Evaluate in Phase II.

164 Provide the capability to power the Provide backup to ESW in conditions with No Evaluate during Phase II normal service water pumps from power only available from AEPS.

AEPS.

171 Increase the size of the RWST or Ensure a supply of makeup water is available No Evaluate during Phase II otherwise improve the availability of from the RWST.

the RWST 178 Improvements to UHS cooling Improve availability or mitigate loss of HVAC. No Evaluate during Phase II tower electrical room HVAC.

179 Modify procedures such that the Prevents possible thermally induced steam No Evaluate during Phase II water loop seals in the RCS cold generator tube rupture following core legs are not cleared following core damage.

damage.

180 Install lower amperage fuses for Reduced fire risk. No Evaluate during Phase II various 14 AWG control circuits in the MCR. The majority of the modification centers around the trip circuit fuses on NB, NG, PA, PB, and PG system breakers.

181 Install redundant fuses and Reduced fire risk. No Evaluate during Phase II isolation switches for MCR evacuation procedure OTO-ZZ-00001.

ULNRC-05908 September 24, 2012 Page 37 of 58 Table 6-1. Callaway Plant Phase I SAMA Analysis (Continued)

Callaway SAMA Screened Number Potential Improvement Discussion Out Ph 1? Screening Criterion Phase I Disposition 182 To protect against multiple spurious Reduced fire risk. No Evaluate during Phase II operation scenarios, cable runs will be changed to run a single wire in a protected metal jacket such that spurious valve opening due to a hot short affecting the valve control circuit is eliminated for the fire area.

This modification will be implemented in multiple fire areas.

183 Quick response sprinkler heads in Reduced fire risk. No Evaluate during Phase II cable chases A-11, C-30, and C-31 will be modified to be in accordance with the applicable requirements of NFPA 13-1976 edition.

184 Improvements in the reliability of More reliable main steam line isolation. No Evaluate during Phase II the Steam Line Isolation automatic signal.

185 Automate initiation of CCW flow to More reliable than manual initiation of flow to No Evaluate during Phase II the RHR heat exchangers. RRHR HX.

186 Develop a procedure and obtain Backup cooling water if ESW/SW is lost No Evaluate during Phase II equipment to provide a temporary hookup of fire water as a replacement for ESW

ULNRC-05908 September 24, 2012 Attachment 1 Page 38 of 58 Table 7-1. Callaway Plant 1 Phase II SAMA Analysis Callaway  % Red.

SAMA  % Red. In OS SAMA SAMA Case  % Red IN Number Potential Improvement Discussion In CDF Dose Case Description Benefit Cost OECR Cost Basis Evaluation Basis for Evaluation 1 Provide additional DC battery Extended DC power 12.17% 10.87% NOSBO No Station Blackout $360K >$1M 10.49% Expert Not Cost- Cost will exceed benefit.

capacity. availability during an SBO. Events Panel Beneficial 2 Replace lead-acid batteries Extended DC power 12.17% 10.87% NOSBO No Station Blackout $360K >$1M 10.49% Expert Not Cost- Cost will exceed benefit.

with fuel cells. availability during an SBO. Events Panel Beneficial 5 Provide DC bus cross-ties. Improved availability of DC 0.30% 0.00% DC01 TDAFW no DC $1K >$199K 0.03% Expert Not Cost- Cost will exceed benefit.

power system. Dependency Panel Beneficial 11 Improve 4.16-kV bus cross- Increased availability of on- 12.17% 10.87% NOSBO No Station Blackout $360K >$1M 10.49% Expert Not Cost- Cost will exceed benefit.

tie ability. site AC power. Events Panel Beneficial Cost for implementation includes analysis, material to be purchased and prestaged, development of procedures, and training of personnel on implementation.,

15 Install tornado protection on Increased availability of on- 2.65% 4.35% LOSP1 No tornado related $91K >$500K 3.38% Expert Not Cost- Cost will exceed benefit.

gas turbine generator. site AC power. LOSP Panel Beneficial 24 Bury off-site power lines. Improved off-site power 40.66% 41.30% NOLOSP Eliminate all Loss of $1.2M >$3M 35.28% Expert Not Cost- Cost will exceed benefit.

reliability during severe Offsite Power Events Panel Beneficial Previous SAMA submittals weather. have estimated approximately $1M per mile.

25 Install an independent active Improved prevention of 2.77% 0.00% LOCA12 No failures of the $48K >$1M 0.35% Expert Not Cost- Cost will exceed benefit.

or passive high pressure core melt sequences. charging or SI pumps Panel Beneficial injection system.

26 Provide an additional high Reduced frequency of core 2.77% 0.00% LOCA12 No failures of the $48K >$1M 0.35% Expert Not Cost- Cost will exceed benefit.

pressure injection pump with melt from small LOCA and charging or SI pumps Panel Beneficial independent diesel. SBO sequences.

28 Add a diverse low pressure Improved injection 3.19% 2.17% LOCA03 No failure of low $65K >$1M 1.01% Expert Not Cost- Cost will exceed benefit.

injection system. capability. pressure injection Panel Beneficial 29 Provide capability for Improved injection Potentially SAMA is judged to be low alternate injection via diesel- capability. Cost- cost, but analysis is driven fire pump. Beneficial needed to determine impacts of injection of non-borated water to RCS.

Expert Panel judged this SAMA to be potentially cost-beneficial without determining an actual benefit or cost.

ULNRC-05908 September 24, 2012 Attachment 1 Page 39 of 58 Table 7-1. Callaway Plant 1 Phase II SAMA Analysis (Continued)

Callaway  % Red.

SAMA  % Red. In OS SAMA SAMA Case  % Red IN Number Potential Improvement Discussion In CDF Dose Case Description Benefit Cost OECR Cost Basis Evaluation Basis for Evaluation 39 Replace two of the four Reduced common cause 2.77% 0.00% LOCA12 No failures of the $48K >$1M 0.35% Expert Not Cost- Cost will exceed benefit.

electric safety injection failure of the safety charging or SI pumps Panel Beneficial pumps with diesel-powered injection system. This pumps. SAMA was originally intended for the Westinghouse-CE System 80+, which has four trains of safety injection.

However, the intent of this SAMA is to provide diversity within the high-and l 41 Create a reactor coolant Allows low pressure 0.78% 0.00% DEPRESS No failures of $12K >$500K 0.27% Expert Not Cost- Cost will exceed benefit.

depressurization system. emergency core cooling depressurization Panel Beneficial system injection in the event of small LOCA and high-pressure safety injection failure.

43 Add redundant DC control Increased availability of 0.30% 0.00% SW01 Service Water Pumps $1K >$100K 0.06% Expert Not Cost- Cost will exceed benefit.

power for SW pumps. SW. not dependent on DC Panel Beneficial Power 46 Add a service water pump. Increased availability of 17.60% 27.72% SW02 No failures of ESW $636K >$5M 23.26% Expert Not Cost- Cost will exceed benefit.

cooling water. pumps Panel Beneficial 54 Increase charging pump lube Increased time before 0.48% 0.00% CHG01 Charging pumps not $4K >$100K 0.06% Expert Not Cost- Cost will exceed benefit.

oil capacity. charging pump failure due dependent on cooling Panel Beneficial to lube oil overheating in water.

loss of cooling water sequences.

55 Install an independent Reduced frequency of core 5.54% 0.00% RCPLOCA No RCP Seal LOCAs $94K >$1M 0.21% Expert Not Cost- Cost will exceed benefit.

reactor coolant pump seal damage from loss of Panel Beneficial Previous investigation into injection system, with component cooling water, installing such a system dedicated diesel. service water, or station concluded that operators blackout. did not have sufficient time to place the system in service prior to seal damage.

56 Install an independent Reduced frequency of core 5.54% 0.00% RCPLOCA No RCP Seal LOCAs $94K >$500K 0.21% Expert Not Cost- Cost will exceed benefit.

reactor coolant pump seal damage from loss of Panel Beneficial injection system, without component cooling water dedicated diesel. or service water, but not a station blackout.

58 Install improved reactor Reduced likelihood of 5.54% 0.00% RCPLOCA No RCP Seal LOCAs $94K >$3M 0.21% Expert Not Cost- Cost will exceed benefit.

coolant pump seals. reactor coolant pump seal Panel Beneficial LOCA.

59 Install an additional Reduced likelihood of loss 3.61% 0.00% CCW01 No failures of the CCW $59K >$1M 0.07% Expert Not Cost- Cost will exceed benefit.

component cooling water of component cooling water Pumps Panel Beneficial pump. leading to a reactor coolant pump seal LOCA.

ULNRC-05908 September 24, 2012 Attachment 1 Page 40 of 58 Table 7-1. Callaway Plant 1 Phase II SAMA Analysis (Continued)

Callaway  % Red.

SAMA  % Red. In OS SAMA SAMA Case  % Red IN Number Potential Improvement Discussion In CDF Dose Case Description Benefit Cost OECR Cost Basis Evaluation Basis for Evaluation 64 Implement procedure and Improved ability to cool 5.39% 0.76% FWCCW Evaluate fire water $104K <150K 0.77%% Expert Potentially The cost estimate is for hardware modifications to residual heat removal heat 2 hookup to RHR HX Panel Cost development of a allow manual alignment of exchangers. Beneficial procedure and use of the fire water system to the temporary connections.

component cooling water Cost of permanent system, or install a modification would be component cooling water significantly higher.

header cross-tie.

65 Install a digital feed water Reduced chance of loss of 1.57% 0.00% FW01 No loss of Feedwater $29K $19M 0.49% Callaway Not Cost- Cost will exceed benefit.

upgrade. main feed water following a Events Modification Beneficial plant trip. Costs 71 Install a new condensate Increased availability of the 1.14% 0.00% CST01 CST does not deplete $18K >$2.5M 0.24% Expert Not Cost- Cost will exceed benefit.

storage tank (auxiliary auxiliary feedwater system. Panel Beneficial feedwater storage tank).

77 Provide a passive, Reduced potential for core 1.57% 0.00% FW01 No loss of Feedwater $29K $>1M 0.49% Expert Not Cost- Cost will exceed benefit.

secondary-side heat- damage due to loss-of- Events Panel Beneficial rejection loop consisting of a feedwater events.

condenser and heat sink.

79 Replace existing pilot- Increased probability of 3.43% 2.17% FB01 Only one PORV $79K >$500K 1.68% Expert Not Cost- Cost will exceed benefit.

operated relief valves with successful feed and bleed. required for Feed & Panel Beneficial larger ones, such that only Bleed one is required for successful feed and bleed.

80 Provide a redundant train or Increased availability of 6.08% 4.35% HVAC No dependencies on $156K >$1M 3.87% Expert Potentially Procedures to open doors means of ventilation. components dependent on HVAC Panel Cost or provide temporary room cooling. Beneficial ventilation may be cost beneficial for the EDGs, MDAFW pumps, and charging pumps.

Procedures for opening doors to the DC switchgear rooms exist.

87 Replace service and Elimination of instrument 0.36% 0.00% INSTAIR Eliminate all instrument $2K >$500K 0.06% Expert Not Cost- Cost will exceed benefit.

instrument air compressors air system dependence on air failures Panel Beneficial with more reliable service water cooling.

compressors which have self-contained air cooling by shaft driven fans.

91 Install a passive containment Improved containment 19.52% 36.96% CONT01 No failures due to $793K >$10M 31.32% Expert Not Cost- Cost will exceed benefit.

spray system. spray capability. containment Panel Beneficial overpressure 93 Install an unfiltered, Increased decay heat 19.52% 36.96% CONT01 No failures due to $793K >$2M 31.32% Expert Not Cost- Cost will exceed benefit.

hardened containment vent. removal capability for non- containment Panel Beneficial ATWS events, without overpressure scrubbing released fission products.

94 Install a filtered containment Increased decay heat 19.52% 36.96% CONT01 No failures due to $793K >$2M 31.32% Expert Not Cost- Cost will exceed benefit.

vent to remove decay heat. removal capability for non- containment Panel Beneficial Option 1: Gravel Bed Filter; ATWS events, with overpressure Option 2: Multiple Venturi scrubbing of released Scrubber fission products.

ULNRC-05908 September 24, 2012 Attachment 1 Page 41 of 58 Table 7-1. Callaway Plant 1 Phase II SAMA Analysis (Continued)

Callaway  % Red.

SAMA  % Red. In OS SAMA SAMA Case  % Red IN Number Potential Improvement Discussion In CDF Dose Case Description Benefit Cost OECR Cost Basis Evaluation Basis for Evaluation 96 Provide post-accident Reduced likelihood of 0.48% 0.00% H2BURN No hydrogen $10K >$100K 0.44% Expert Not Cost- Cost will exceed benefit.

containment inerting hydrogen and carbon burns/explosions Panel Beneficial capability. monoxide gas combustion.

97 Create a large concrete Increased cooling and MAB >$10M Note 1 Expert Not Cost- Cost will exceed benefit.

crucible with heat removal containment of molten core Panel Beneficial potential to contain molten debris. Molten core debris core debris. escaping from the vessel is contained within the crucible and a water cooling mechanism cools the molten core in the crucible, preventing melt-through of the base mat.

98 Create a core melt source Increased cooling and MAB >$10M Note 1 Expert Not Cost- Cost will exceed benefit.

reduction system. containment of molten core Panel Beneficial debris. Refractory material would be placed underneath the reactor vessel such that a molten core falling on the material would melt and combine with the material.

Subsequent spreading and heat removal from the vitrified compound would be facilitated, and concrete attack would not occur.

99 Strengthen Reduced probability of 19.52% 36.96% CONT01 No failures due to $1.2M >$10M 31.32% Expert Not Cost- Cost will exceed benefit.

primary/secondary containment over- containment Panel Beneficial containment (e.g., add pressurization. overpressure ribbing to containment shell).

100 Increase depth of the Reduced probability of MAB >$10M Note 1 Expert Not Cost- Cost will exceed benefit.

concrete base mat or use an base mat melt-through. Panel Beneficial alternate concrete material to ensure melt-through does not occur.

102 Construct a building to be Reduced probability of 19.52% 36.96% CONT01 No failures due to $1.2M >$10M 31.32% Expert Not Cost- Cost will exceed benefit.

connected to containment over- containment Panel Beneficial primary/secondary pressurization. overpressure containment and maintained at a vacuum.

104 Improve leak detection Increased piping 39.34% 2.17% LOCA05 No piping system $689K >$2M 1.03% Expert Not Cost- Cost will exceed benefit.

procedures. surveillance to identify LOCAs Panel Beneficial leaks prior to complete failure. Improved leak detection would reduce LOCA frequency.

107 Install a redundant Increased containment 19.52% 36.96% CONT01 No failures due to $1.2M >$2M 31.32% Expert Not Cost- Cost will exceed benefit.

containment spray system. heat removal ability. containment Panel Beneficial overpressure

ULNRC-05908 September 24, 2012 Attachment 1 Page 42 of 58 Table 7-1. Callaway Plant 1 Phase II SAMA Analysis (Continued)

Callaway  % Red.

SAMA  % Red. In OS SAMA SAMA Case  % Red IN Number Potential Improvement Discussion In CDF Dose Case Description Benefit Cost OECR Cost Basis Evaluation Basis for Evaluation 108 Install an independent power Reduced hydrogen 0.48% 0.00% H2BURN No hydrogen $10K >$100K 0.44% Expert Not Cost-supply to the hydrogen detonation potential. burns/explosions Panel Beneficial control system using either new batteries, a non-safety grade portable generator, existing station batteries, or existing AC/DC independent power supplies, such as the security system diesel.

109 Install a passive hydrogen Reduced hydrogen 0.48% 0.00% H2BURN No hydrogen $10K >$100M 0.44% Expert Not Cost- Cost will exceed benefit.

control system. detonation potential. burns/explosions Panel Beneficial 110 Erect a barrier that would Reduced probability of MAB >$10M Note 1 Expert Not Cost- Cost will exceed benefit.

provide enhanced protection containment failure. Panel Beneficial of the containment walls (shell) from ejected core debris following a core melt scenario at high pressure.

111 Install additional pressure or Reduced ISLOCA 1.33% 8.70% ISLOCA No ISLOCA events $123K >$500K 7.08% Expert Not Cost- Cost will exceed benefit.

leak monitoring instruments frequency. Panel Beneficial for detection of ISLOCAs.

112 Add redundant and diverse Reduced frequency of 0.30% 0.00% CONT02 No failures of $1K >$1M Expert Not Cost- Cost will exceed benefit.

limit switches to each containment isolation containment isolation Panel Beneficial containment isolation valve. failure and ISLOCAs.

113 Increase leak testing of Reduced ISLOCA 1.33% 8.70% ISLOCA No ISLOCA events $123K >$1M 7.08% Expert Not Cost- Cost will exceed benefit.

valves in ISLOCA paths. frequency. Panel Beneficial 114 Install self-actuating Reduced frequency of 0.30% 0.00% CONT02 No failures of $1K >$500K 0.03% Expert Not Cost- Cost will exceed benefit.

containment isolation valves. isolation failure. containment isolation Panel Beneficial 115 Locate residual heat removal Reduced frequency of 1.33% 8.70% ISLOCA No ISLOCA events $123K >$1M 7.08% Expert Not Cost- Cost will exceed benefit.

(RHR) inside containment ISLOCA outside Panel Beneficial containment.

116 Ensure ISLOCA releases are Scrubbed ISLOCA 1.33% 8.70% ISLOCA No ISLOCA events $123K >$1M 7.08% Expert Not Cost- Cost would exceed benefit.

scrubbed. One method is to releases. Panel Beneficial Current plant design plug drains in potential break requires drains to be open.

areas so that break point will Analysis and license be covered with water. changes required to implement are included in the cost estimate.

119 Institute a maintenance Reduced frequency of 20.47% 63.28% NOSGTR No SGTR Events $1.4M >$3M 69.43% Expert Not Cost- Cost will exceed benefit.

practice to perform a 100% steam generator tube Panel Beneficial inspection of steam ruptures.

generator tubes during each refueling outage.

121 Increase the pressure Eliminates release pathway 20.47% 63.28% NOSGTR No SGTR Events $1.4M >$10M 69.43% Expert Not Cost- Cost will exceed benefit.

capacity of the secondary to the environment Panel Beneficial side so that a steam following a steam generator tube rupture would generator tube rupture.

not cause the relief valves to lift.

ULNRC-05908 September 24, 2012 Attachment 1 Page 43 of 58 Table 7-1. Callaway Plant 1 Phase II SAMA Analysis (Continued)

Callaway  % Red.

SAMA  % Red. In OS SAMA SAMA Case  % Red IN Number Potential Improvement Discussion In CDF Dose Case Description Benefit Cost OECR Cost Basis Evaluation Basis for Evaluation 122 Install a redundant spray Enhanced depressurization 20.47% 63.28% NOSGTR No SGTR Events $1.4M >$10M 69.43% Expert Not Cost- Cost will exceed benefit.

system to depressurize the capabilities during steam Panel Beneficial primary system during a generator tube rupture.

steam generator tube rupture 125 Route the discharge from the Reduced consequences of 20.47% 63.28% NOSGTR No SGTR Events $1.4M >$10M 69.43% Expert Not Cost- Cost will exceed benefit.

main steam safety valves a steam generator tube Panel Beneficial through a structure where a rupture.

water spray would condense the steam and remove most of the fission products.

126 Install a highly reliable Reduced consequences of 20.47% 63.28% NOSGTR No SGTR Events $1.4M >$10M 69.43% Expert Not Cost- Cost will exceed benefit.

(closed loop) steam a steam generator tube Panel Beneficial generator shell-side heat rupture.

removal system that relies on natural circulation and stored water sources 129 Vent main steam safety Reduced consequences of 20.47% 63.28% NOSGTR No SGTR Events $1.4M >$10M 69.43% Expert Not Cost- Cost will exceed benefit.

valves in containment. a steam generator tube Panel Beneficial Current containment rupture. design does not support this modification.

Modifications to containment and associated analysis are included in the cost estimate.

130 Add an independent boron Improved availability of 2.41% 2.17% NOATWS Eliminate all ATWS $63K >$1M 1.85% Expert Not Cost- Cost will exceed benefit.

injection system. boron injection during Panel Beneficial ATWS.

131 Add a system of relief valves Improved equipment 2.41% 2.17% NOATWS Eliminate all ATWS $63K >$2M 1.85% Expert Not Cost- Cost will exceed benefit.

to prevent equipment availability after an ATWS. Panel Beneficial damage from pressure spikes during an ATWS.

133 Install an ATWS sized filtered Increased ability to remove 2.41% 2.17% NOATWS Eliminate all ATWS $63K >$1M 1.85% Expert Not Cost- Cost will exceed benefit containment vent to remove reactor heat from ATWS Panel Beneficial decay heat. events.

136 Install motor generator set Reduced frequency of core 2.41% 2.17% NOATWS Eliminate all ATWS $63K >$500K 1.85% Expert Not Cost- Cost will exceed benefit.

trip breakers in control room. damage due to an ATWS. Panel Beneficial 147 Install digital large break Reduced probability of a 39.34% 2.17% LOCA05 No piping system $689K >$5M 1.03% Expert Not Cost- Cost will exceed benefit.

LOCA protection system. large break LOCA (a leak LOCAs Panel Beneficial before break).

153 Install secondary side guard Prevents secondary side 2.53% 0.00% NOSLB No Steam Line Breaks $51K >$1M 0.87% Expert Not Cost- Cost will exceed benefit.

pipes up to the main steam depressurization should a Panel Beneficial isolation valves. steam line break occur upstream of the main steam isolation valves.

Also guards against or prevents consequential multiple steam generator tube ruptures following a main steam line break event.

ULNRC-05908 September 24, 2012 Attachment 1 Page 44 of 58 Table 7-1. Callaway Plant 1 Phase II SAMA Analysis (Continued)

Callaway  % Red.

SAMA  % Red. In OS SAMA SAMA Case  % Red IN Number Potential Improvement Discussion In CDF Dose Case Description Benefit Cost OECR Cost Basis Evaluation Basis for Evaluation 160 Modifications to lessen Lower impact of flood that <$50K Expert Potentially Relatively minor impact of internal flooding propagates through the Panel Cost- modifications to door path through Control Building dumbwaiter Beneficial opening could result in dumbwaiter. lower flow to the dumbwaiter. Specific benefit could not be calculated but SAMA item is judged to be low cost and therefore potentially cost beneficial.

161 Improvements to PORV Decrease in risk due to 0.85% 0.46% PORV PORVs do not fail to $18K >$100K 0.24% Expert Not Cost- Cost will exceed benefit.

performance that will lower PORV failing to open. open Panel Beneficial the probability of failure to open.

162 Install a large volume EDG Allows transfer of EDF fuel 1.14% 7.60% EDGFUEL No EDG fuel pump $124K $150K 7.11% Wolf Creek Potentially Wolf Creek estimated cost fuel oil tank at an elevation oil to the EDG day tanks on failures Cost- of $150K is less than the greater than the EDG fuel oil failure of the fuel oil Beneficial potential benefit.

day tanks. transfer pumps.

163 Improve feedwater check Lower risk due to failures in 5.52% 2.05% FW02 Feedwater Check $127K >$500K 2.23% Expert Not Cost- Cost will exceed benefit.

valve reliability to reduce which feedwater check Valves do not fail to Panel Beneficial probability of failure to open. valves fail to open and open allow feeding of the steam generators.

164 Provide the capability to Provide backup to ESW in 5.62% 7.64% SW03 AEPS power to SW $191K >$500K 6.37% Expert Not Cost- Cost will exceed benefit.

power the normal service conditions with power only pumps Panel Beneficial water pumps from AEPS. available from AEPS.

171 Increase the size of the Ensure a supply of makeup 0.68% 0.13% LOCA04 RWST does not $13K >$100K 0.07% Expert Not Cost- Cost will exceed benefit.

RWST or otherwise improve water is available from the deplete Panel Beneficial the availability of the RWST RWST.

178 Improvements to UHS Improve availability or 3.29% 4.75% HVAC02 UHS cooling tower $113K 3.82% Expert Potentially Implementation of cooling tower electrical room mitigate loss of HVAC.  % electrical room HVAC Panel Cost temporary ventilation or HVAC. does not fail. Beneficial opening of doors will be a lower cost than the calculated benefit.

179 Modify procedures such that Prevents possible thermally 0.15% 3.18% RAI7a Reduced probability of $63K 4.46% Expert Potentially Implementation of the water loop seals in the induced steam generator thermally induced Panel Cost procedure change will be RCS cold legs are not tube rupture following core steam generator tube Beneficial lower cost than benefit, cleared following core damage. failure especially if 95% CDF damage. benefit is considered.

180 Install lower amperage fuses Reduced fire risk. Potentially SAMA considered for various 14 AWG control Cost potentially cost beneficial circuits in the MCR. The Beneficial without benefit or cost majority of the modification determination since the centers around the trip circuit NFPA 805 license fuses on NB, NG, PA, PB, amendment request and PG system breakers. committed to performing the modification.

ULNRC-05908 September 24, 2012 Attachment 1 Page 45 of 58 Table 7-1. Callaway Plant 1 Phase II SAMA Analysis (Continued)

Callaway  % Red.

SAMA  % Red. In OS SAMA SAMA Case  % Red IN Number Potential Improvement Discussion In CDF Dose Case Description Benefit Cost OECR Cost Basis Evaluation Basis for Evaluation 181 Install redundant fuses and Reduced fire risk. Potentially SAMA considered isolation switches for MCR Cost potentially cost beneficial evacuation procedure OTO- Beneficial without benefit or cost ZZ-00001. determination since the NFPA 805 license amendment request committed to performing the modification.

182 To protect against multiple Reduced fire risk. Potentially SAMA considered spurious operation scenarios, Cost potentially cost beneficial cable runs will be changed to Beneficial without benefit or cost run a single wire in a determination since the protected metal jacket such NFPA 805 license that spurious valve opening amendment request due to a hot short affecting committed to performing the valve control circuit is the modification.

eliminated for the fire area.

This modification will be implemented in multiple fire areas.

183 Quick response sprinkler Reduced fire risk. Potentially SAMA considered heads in cable chases A-11, Cost potentially cost beneficial C-30, and C-31 will be Beneficial without benefit or cost modified to be in accordance determination since the with the applicable NFPA 805 license requirements of NFPA 13- amendment request 1976 edition. committed to performing the modification.

184 Improvements in the More reliable main steam 0.59% 0.95% SLIS Steam Line Isolation $28K >500K 1.06% Expert Not Cost- Cost is for installation of reliability of the Steam Line line isolation. System does not fail Panel Beneficial redundant instrumentation Isolation automatic signal. system and would likely be much higher. Procedure and training already direct operators to manually back up failed automatic actuations.

185 Automate initiation of CCW More reliable than manual 3.53% 0.14% HEP Evaluate automating $62K >$500K 0.11% Expert Not Cost- Cost will exceed benefit.

flow to the RHR heat initiation of flow to RRHR CCW flow to RHR HXs Panel Beneficial exchangers. HX.

186 Develop a procedure and Backup cooling water if 17.60% 27.72% SW02 No failures of ESW $636K >$1M 23.26% Expert Potentially Ability to do this will require obtain equipment to provide ESW/SW is lost pumps Panel Cost larger fire pumps a temporary hookup of fire Beneficial water as a replacement for ESW

ULNRC-05908 September 24, 2012 Page 46 of 58 Table 7-1. Callaway Plant 1 Phase II SAMA Analysis (Continued)

OS = off site Note 1: For SAMA items that were judged to cost significantly more than the Maximum Attainable Benefit (MAB), no calculation of the individual benefit was performed.

ULNRC-05908 September 24, 2012 Attachment 1 Page 47 of 58 Table 8-1. Callaway Plant Sensitivity Evaluation Callaway Benefit at Benefit at Benefit SAMA SAMA 3% Disc Realistic Benefit at 95%

Number Potential Improvement Discussion Case Benefit Rate Disc Rate at 33yrs CDF Cost Cost Basis Evaluation Basis for Evaluation 1 Provide additional DC battery Extended DC power availability NOSBO $360K $588K $325K $512K $761K >$1M Expert Panel Not Cost- Cost will exceed capacity. during an SBO. Beneficial benefit.

2 Replace lead-acid batteries with fuel Extended DC power availability NOSBO $360K $588K $325K $512K $761K >$1M Expert Panel Not Cost- Cost will exceed cells. during an SBO. Beneficial benefit.

5 Provide DC bus cross-ties. Improved availability of DC DC01 $1K $1K $1K $1K $1K >$199K Expert Panel Not Cost- Cost will exceed power system. Beneficial benefit.

11 Improve 4.16-kV bus cross-tie ability. Increased availability of on-site NOSBO $360K $588K $325K $512K $761K >$1M Expert Panel Not Cost- Cost will exceed AC power. Beneficial benefit. Cost for implementation includes analysis, material to be purchased and prestaged, development of procedures, and training of personnel on implementation.,

15 Install tornado protection on gas Increased availability of on-site LOSP1 $91K $144K $82K $125K $192K >$500K Expert Panel Not Cost- Cost will exceed turbine generator. AC power. Beneficial benefit.

24 Bury off-site power lines. Improved off-site power reliability NOLOSP $1.2M $2.0M $1.1M $1.7M $2.6M >$3M Expert Panel Not Cost- Cost will exceed during severe weather. Beneficial benefit. Previous SAMA submittals have estimated approximately $1M per mile.

25 Install an independent active or Improved prevention of core melt LOCA12 $48K $85K $44K $75 $102 >$1M Expert Panel Not Cost- Cost will exceed passive high pressure injection sequences. Beneficial benefit.

system.

26 Provide an additional high pressure Reduced frequency of core melt LOCA12 $48K $85K $44K $75 $102 >$1M Expert Panel Not Cost- Cost will exceed injection pump with independent from small LOCA and SBO Beneficial benefit.

diesel. sequences.

28 Add a diverse low pressure injection Improved injection capability. LOCA03 $65K $111K $58K $97K $137K >$1M Expert Panel Not Cost- Cost will exceed system. Beneficial benefit.

29 Provide capability for alternate Improved injection capability. Potentially SAMA is judged to be injection via diesel-driven fire pump. Cost-Beneficial low cost, but analysis is needed to determine impacts of injection of non-borated water to RCS.

Expert Panel judged this SAMA to be potentially cost-beneficial without determining an actual benefit or cost.

ULNRC-05908 September 24, 2012 Attachment 1 Page 48 of 58 Table 8-1. Callaway Plant Sensitivity Evaluation (Continued)

Callaway Benefit at Benefit at Benefit SAMA SAMA 3% Disc Realistic Benefit at 95%

Number Potential Improvement Discussion Case Benefit Rate Disc Rate at 33yrs CDF Cost Cost Basis Evaluation Basis for Evaluation 39 Replace two of the four electric safety Reduced common cause failure LOCA12 $48K $85K $44K $75 $102 >$1M Expert Panel Not Cost- Cost will exceed injection pumps with diesel-powered of the safety injection system. Beneficial benefit.

pumps. This SAMA was originally intended for the Westinghouse-CE System 80+, which has four trains of safety injection.

However, the intent of this SAMA is to provide diversity within the high- and l 41 Create a reactor coolant Allows low pressure emergency DEPRESS $12K $20K $11K $17K $25K >$500K Expert Panel Not Cost- Cost will exceed depressurization system. core cooling system injection in Beneficial benefit.

the event of small LOCA and high-pressure safety injection failure.

43 Add redundant DC control power for Increased availability of SW. SW01 $1K $2K $1K $2K $3K >$100K Expert Panel Not Cost- Cost will exceed SW pumps. Beneficial benefit.

46 Add a service water pump. Increased availability of cooling SW02 $636K $1M $575K $879K $1.3M >$5M Expert Panel Not Cost- Cost will exceed water. Beneficial benefit.

54 Increase charging pump lube oil Increased time before charging CHG01 $4K $7K $4K $6K $9K >$100K Expert Panel Not Cost- Cost will exceed capacity. pump failure due to lube oil Beneficial benefit.

overheating in loss of cooling water sequences.

55 Install an independent reactor coolant Reduced frequency of core RCPLOCA $94K $168K $85K $148K $198K >$1M Expert Panel Not Cost- Cost will exceed pump seal injection system, with damage from loss of component Beneficial benefit. Previous dedicated diesel. cooling water, service water, or investigation into station blackout. installing such a system concluded that operators did not have sufficient time to place the system in service prior to seal damage.

56 Install an independent reactor coolant Reduced frequency of core RCPLOCA $94K $168K $85K $148K $198K >$500K Expert Panel Not Cost- Cost will exceed pump seal injection system, without damage from loss of component Beneficial benefit.

dedicated diesel. cooling water or service water, but not a station blackout.

58 Install improved reactor coolant pump Reduced likelihood of reactor RCPLOCA $94K $168K $85K $148K $198K >$3M Not Cost- Cost will exceed seals. coolant pump seal LOCA. Beneficial benefit.

59 Install an additional component Reduced likelihood of loss of CCW01 $59K $106K $53K $93K $124K >$1M Cost will Not Cost- Cost will exceed cooling water pump. component cooling water leading exceed Beneficial benefit.

to a reactor coolant pump seal benefit LOCA.

ULNRC-05908 September 24, 2012 Attachment 1 Page 49 of 58 Table 8-1. Callaway Plant Sensitivity Evaluation (Continued)

Callaway Benefit at Benefit at Benefit SAMA SAMA 3% Disc Realistic Benefit at 95%

Number Potential Improvement Discussion Case Benefit Rate Disc Rate at 33yrs CDF Cost Cost Basis Evaluation Basis for Evaluation 64 Implement procedure and hardware Improved ability to cool residual FWCCW2 $104K $184K $94K $161K $220K <150K Expert Panel Potentially Cost The cost estimate is modifications to allow manual heat removal heat exchangers. Beneficial for development of a alignment of the fire water system to procedure and use of the component cooling water system, temporary or install a component cooling water connections. Cost of header cross-tie. permanent modification would be significantly higher.

65 Install a digital feed water upgrade. Reduced chance of loss of main FW01 $29K $50K $27K $44K $62K $19M Callaway Not Cost- Cost will exceed feed water following a plant trip. Modification Beneficial benefit.

Costs 71 Install a new condensate storage Increased availability of the CST01 $18K $32K $16K $28K $39K >$2.5M Expert Panel Not Cost- Cost will exceed tank (auxiliary feedwater storage auxiliary feedwater system. Beneficial benefit.

tank).

77 Provide a passive, secondary-side Reduced potential for core FW01 $29K $50K $27K $44K $62K $>1M Expert Panel Not Cost- Cost will exceed heat-rejection loop consisting of a damage due to loss-of-feedwater Beneficial benefit.

condenser and heat sink. events.

79 Replace existing pilot-operated relief Increased probability of FB01 $79K $133K $72K $117K $168K >$500K Expert Panel Not Cost- Cost will exceed valves with larger ones, such that successful feed and bleed. Beneficial benefit.

only one is required for successful feed and bleed.

80 Provide a redundant train or means Increased availability of HVAC $156K $259K $141K $227K $331K >$1M Expert Panel Potentially Cost Procedures to open of ventilation. components dependent on room Beneficial doors or provide cooling. temporary ventilation may be cost beneficial for the EDGs, MDAFW pumps, and charging pumps. Procedures for opening doors to the DC switchgear rooms exist.

87 Replace service and instrument air Elimination of instrument air INSTAIR $2K $3K $2K $$2K $4K >$500K Expert Panel Not Cost- Cost will exceed compressors with more reliable system dependence on service Beneficial benefit.

compressors which have self- water cooling.

contained air cooling by shaft driven fans.

91 Install a passive containment spray Improved containment spray CONT01 $793K $1.2M $717K $1.1M $1.7M >$10M Expert Panel Not Cost- Cost will exceed system. capability. Beneficial benefit.

93 Install an unfiltered, hardened Increased decay heat removal CONT01 $793K $1.2M $717K $1.1M $1.7M >$2M Expert Panel Not Cost- Cost will exceed containment vent. capability for non-ATWS events, Beneficial benefit.

without scrubbing released fission products.

94 Install a filtered containment vent to Increased decay heat removal CONT01 $793K $1.2M $717K $1.1M $1.7M >$2M Expert Panel Not Cost- Cost will exceed remove decay heat. Option 1: Gravel capability for non-ATWS events, Beneficial benefit.

Bed Filter; Option 2: Multiple Venturi with scrubbing of released fission Scrubber products.

96 Provide post-accident containment Reduced likelihood of hydrogen H2BURN $10K $15K $9K $13K $20K >$100K Expert Panel Not Cost- Cost will exceed inerting capability. and carbon monoxide gas Beneficial benefit.

combustion.

ULNRC-05908 September 24, 2012 Attachment 1 Page 50 of 58 Table 8-1. Callaway Plant Sensitivity Evaluation (Continued)

Callaway Benefit at Benefit at Benefit SAMA SAMA 3% Disc Realistic Benefit at 95%

Number Potential Improvement Discussion Case Benefit Rate Disc Rate at 33yrs CDF Cost Cost Basis Evaluation Basis for Evaluation 97 Create a large concrete crucible with Increased cooling and MAB >$10M Expert Panel Not Cost- Cost will exceed heat removal potential to contain containment of molten core Beneficial benefit.

molten core debris. debris. Molten core debris escaping from the vessel is contained within the crucible and a water cooling mechanism cools the molten core in the crucible, preventing melt-through of the base mat.

98 Create a core melt source reduction Increased cooling and MAB >$10M Expert Panel Not Cost- Cost will exceed system. containment of molten core Beneficial benefit.

debris. Refractory material would be placed underneath the reactor vessel such that a molten core falling on the material would melt and combine with the material. Subsequent spreading and heat removal from the vitrified compound would be facilitated, and concrete attack would not occur.

99 Strengthen primary/secondary Reduced probability of CONT01 $1.2M $1.2M $717K $1.1M $1.7M >$10M Expert Panel Not Cost- Cost will exceed containment (e.g., add ribbing to containment over-pressurization. Beneficial benefit.

containment shell).

100 Increase depth of the concrete base Reduced probability of base mat MAB >$10M Expert Panel Not Cost- Cost will exceed mat or use an alternate concrete melt-through. Beneficial benefit.

material to ensure melt-through does not occur.

102 Construct a building to be connected Reduced probability of CONT01 $1.2M $1.2M $717K $1.1M $1.7M >$10M Expert Panel Not Cost- Cost will exceed to primary/secondary containment containment over-pressurization. Beneficial benefit.

and maintained at a vacuum.

104 Improve leak detection procedures. Increased piping surveillance to LOCA05 $685K $1.2M $620K $1.1M $1.5M >$2M Expert Panel Not Cost- Cost will exceed identify leaks prior to complete Beneficial benefit.

failure. Improved leak detection would reduce LOCA frequency.

107 Install a redundant containment spray Increased containment heat CONT01 $1.2M $1.2M $717K $1.1M $1.7M >$2M Expert Panel Not Cost- Cost will exceed system. removal ability. Beneficial benefit.

108 Install an independent power supply Reduced hydrogen detonation H2BURN $10K $15K $9K $13K $20K >$100K Expert Panel Not Cost-to the hydrogen control system using potential. Beneficial either new batteries, a non-safety grade portable generator, existing station batteries, or existing AC/DC independent power supplies, such as the security system diesel.

109 Install a passive hydrogen control Reduced hydrogen detonation H2BURN $10K $15K $9K $13K $20K >$100M Expert Panel Not Cost- Cost will exceed system. potential. Beneficial benefit.

110 Erect a barrier that would provide Reduced probability of MAB >$10M Expert Panel Not Cost- Cost will exceed enhanced protection of the containment failure. Beneficial benefit.

containment walls (shell) from ejected core debris following a core melt scenario at high pressure.

ULNRC-05908 September 24, 2012 Attachment 1 Page 51 of 58 Table 8-1. Callaway Plant Sensitivity Evaluation (Continued)

Callaway Benefit at Benefit at Benefit SAMA SAMA 3% Disc Realistic Benefit at 95%

Number Potential Improvement Discussion Case Benefit Rate Disc Rate at 33yrs CDF Cost Cost Basis Evaluation Basis for Evaluation 111 Install additional pressure or leak Reduced ISLOCA frequency. ISLOCA $123K $179K $111K $154K $259K >$500K Expert Panel Not Cost- Cost will exceed monitoring instruments for detection Beneficial benefit.

of ISLOCAs.

112 Add redundant and diverse limit Reduced frequency of CONT02 $1K $1K $1K $1K $2K >$1M Expert Panel Not Cost- Cost will exceed switches to each containment containment isolation failure and Beneficial benefit.

isolation valve. ISLOCAs.

113 Increase leak testing of valves in Reduced ISLOCA frequency. ISLOCA $123K $179K $111K $154K $259K >$1M Expert Panel Not Cost- Cost will exceed ISLOCA paths. Beneficial benefit.

114 Install self-actuating containment Reduced frequency of isolation CONT02 $1K $1K $1K $1K $2K >$500K Expert Panel Not Cost- Cost will exceed isolation valves. failure. Beneficial benefit.

115 Locate residual heat removal (RHR) Reduced frequency of ISLOCA ISLOCA $123K $179K $111K $154K $259K >$1M Expert Panel Not Cost- Cost will exceed inside containment outside containment. Beneficial benefit.

116 Ensure ISLOCA releases are Scrubbed ISLOCA releases. ISLOCA $123K $179K $111K $154K $259K >$1M Expert Panel Not Cost- Cost would exceed scrubbed. One method is to plug Beneficial benefit. Current plant drains in potential break areas so that design requires break point will be covered with drains to be open.

water. Analysis and license changes required to implement are included in the cost estimate.

119 Institute a maintenance practice to Reduced frequency of steam NOSGTR $1.4M $2.1M $1.2M $1.8M $2.9M >$3M Expert Panel Not Cost- Cost will exceed perform a 100% inspection of steam generator tube ruptures. Beneficial benefit.

generator tubes during each refueling outage.

121 Increase the pressure capacity of the Eliminates release pathway to NOSGTR $1.4M $2.1M $1.2M $1.8M $2.9M >$10M Expert Panel Not Cost- Cost will exceed secondary side so that a steam the environment following a Beneficial benefit.

generator tube rupture would not steam generator tube rupture.

cause the relief valves to lift.

122 Install a redundant spray system to Enhanced depressurization NOSGTR $1.4M $2.1M $1.2M $1.8M $2.9M >$10M Expert Panel Not Cost- Cost will exceed depressurize the primary system capabilities during steam Beneficial benefit.

during a steam generator tube generator tube rupture.

rupture 125 Route the discharge from the main Reduced consequences of a NOSGTR $1.4M $2.1M $1.2M $1.8M $2.9M >$10M Expert Panel Not Cost- Cost will exceed steam safety valves through a steam generator tube rupture. Beneficial benefit.

structure where a water spray would condense the steam and remove most of the fission products.

126 Install a highly reliable (closed loop) Reduced consequences of a NOSGTR $1.4M $2.1M $1.2M $1.8M $2.9M >$10M Expert Panel Not Cost- Cost will exceed steam generator shell-side heat steam generator tube rupture. Beneficial benefit.

removal system that relies on natural circulation and stored water sources 129 Vent main steam safety valves in Reduced consequences of a NOSGTR $1.4M $2.1M $1.2M $1.8M $2.9M >$10M Expert Panel Not Cost- Cost will exceed containment. steam generator tube rupture. Beneficial benefit. Current containment design does not support this modification.

Modifications to containment and associated analysis are included in the cost estimate.

ULNRC-05908 September 24, 2012 Attachment 1 Page 52 of 58 Table 8-1. Callaway Plant Sensitivity Evaluation (Continued)

Callaway Benefit at Benefit at Benefit SAMA SAMA 3% Disc Realistic Benefit at 95%

Number Potential Improvement Discussion Case Benefit Rate Disc Rate at 33yrs CDF Cost Cost Basis Evaluation Basis for Evaluation 130 Add an independent boron injection Improved availability of boron NOATWS $63K $104K $57K $90K $134K >$1M Expert Panel Not Cost- Cost will exceed system. injection during ATWS. Beneficial benefit.

131 Add a system of relief valves to Improved equipment availability NOATWS $63K $104K $57K $90K $134K >$2M Expert Panel Not Cost- Cost will exceed prevent equipment damage from after an ATWS. Beneficial benefit.

pressure spikes during an ATWS.

133 Install an ATWS sized filtered Increased ability to remove NOATWS $63K $104K $57K $90K $134K >$1M Expert Panel Not Cost- Cost will exceed containment vent to remove decay reactor heat from ATWS events. Beneficial benefit heat.

136 Install motor generator set trip Reduced frequency of core NOATWS $63K $104K $57K $90K $134K >$500K Expert Panel Not Cost- Cost will exceed breakers in control room. damage due to an ATWS. Beneficial benefit.

147 Install digital large break LOCA Reduced probability of a large LOCA05 $689K $1.2M $620K $1.1M $1.5M >$5M Expert Panel Not Cost- Cost will exceed protection system. break LOCA (a leak before Beneficial benefit.

break).

153 Install secondary side guard pipes up Prevents secondary side NOSLB $51K $87K $46K $77K $108K >$1M Expert Panel Not Cost- Cost will exceed to the main steam isolation valves. depressurization should a steam Beneficial benefit.

line break occur upstream of the main steam isolation valves.

Also guards against or prevents consequential multiple steam generator tube ruptures following a main steam line break event.

160 Modifications to lessen impact of Lower impact of flood that <$50K Expert Panel Potentially Relatively minor internal flooding path through Control propagates through the Cost-Beneficial modifications to door Building dumbwaiter. dumbwaiter opening could result in lower flow to the dumbwaiter. Specific benefit could not be calculated but SAMA item is judged to be low cost and therefore potentially cost beneficial.

161 Improvements to PORV performance Decrease in risk due to PORV PORV $18K $32K $16K $28K $39K >$100K Expert Panel Not Cost- Cost will exceed that will lower the probability of failure failing to open. Beneficial benefit.

to open.

162 Install a large volume EDG fuel oil Allows transfer of EDF fuel oil to EDGFUEL $124K $131K $113K $156K $263K $150K Wolf Creek Potentially Wolf Creek estimated tank at an elevation greater than the the EDG day tanks on failure of Cost-Beneficial cost of $150K is less EDG fuel oil day tanks. the fuel oil transfer pumps. than the potential benefit.

163 Improve feedwater check valve Lower risk due to failures in FW02 $127K $218K $115K $191K $270K >$500K Expert Panel Not Cost- Cost will exceed reliability to reduce probability of which feedwater check valves fail Beneficial benefit.

failure to open. to open and allow feeding of the steam generators.

164 Provide the capability to power the Provide backup to ESW in SW03 $1191K $307K $172K $267K $403K >$500K Expert Panel Not Cost- Cost will exceed normal service water pumps from conditions with power only Beneficial benefit.

AEPS. available from AEPS.

171 Increase the size of the RWST or Ensure a supply of makeup LOCA04 $13K $23K $12K $20K $27K >$100K Expert Panel Not Cost- Cost will exceed otherwise improve the availability of water is available from the Beneficial benefit.

the RWST RWST.

ULNRC-05908 September 24, 2012 Attachment 1 Page 53 of 58 Table 8-1. Callaway Plant Sensitivity Evaluation (Continued)

Callaway Benefit at Benefit at Benefit SAMA SAMA 3% Disc Realistic Benefit at 95%

Number Potential Improvement Discussion Case Benefit Rate Disc Rate at 33yrs CDF Cost Cost Basis Evaluation Basis for Evaluation 178 Improvements to UHS cooling tower Improve availability or mitigate HVAC02 $113K $181K $102K $158K $239K <100K Expert Panel Potentially Cost Implementation of electrical room HVAC. loss of HVAC. Beneficial temporary ventilation or opening of doors will be a lower cost than the calculated benefit.

179 Modify procedures such that the Prevents possible thermally RAI7a $63K $87K $57K $75K $134K Expert Panel Potentially Cost Implementation of water loop seals in the RCS cold legs induced steam generator tube Beneficial procedure change are not cleared following core rupture following core damage. will be lower cost damage. than benefit, especially if 95%

CDF benefit is considered.

180 Install lower amperage fuses for Reduced fire risk. Potentially Cost SAMA considered various 14 AWG control circuits in the Beneficial potentially cost MCR. The majority of the beneficial without modification centers around the trip benefit or cost circuit fuses on NB, NG, PA, PB, and determination since PG system breakers. the NFPA 805 license amandment request committed to performing the modification.

181 Install redundant fuses and isolation Reduced fire risk. Potentially Cost SAMA considered switches for MCR evacuation Beneficial potentially cost procedure OTO-ZZ-00001. beneficial without benefit or cost determination since the NFPA 805 license amendment request committed to performing the modification.

182 To protect against multiple spurious Reduced fire risk. Potentially Cost SAMA considered operation scenarios, cable runs will Beneficial potentially cost be changed to run a single wire in a beneficial without protected metal jacket such that benefit or cost spurious valve opening due to a hot determination since short affecting the valve control circuit the NFPA 805 is eliminated for the fire area. This license amendment modification will be implemented in request committed to multiple fire areas. performing the modification.

183 Quick response sprinkler heads in Reduced fire risk. Potentially Cost SAMA considered cable chases A-11, C-30, and C-31 Beneficial potentially cost will be modified to be in accordance beneficial without with the applicable requirements of benefit or cost NFPA 13-1976 edition. determination since the NFPA 805 license amendment request committed to performing the modification.

ULNRC-05908 September 24, 2012 Attachment 1 Page 54 of 58 Table 8-1. Callaway Plant Sensitivity Evaluation (Continued)

Callaway Benefit at Benefit at Benefit SAMA SAMA 3% Disc Realistic Benefit at 95%

Number Potential Improvement Discussion Case Benefit Rate Disc Rate at 33yrs CDF Cost Cost Basis Evaluation Basis for Evaluation 184 Improvements in the reliability of the More reliable main steam line SLIS $28K $40K $23K $35K $55K >$500K Expert Panel Not Cost- Cost is for installation Steam Line Isolation automatic isolation. Beneficial of redundant signal. instrumentation system and would likely be much higher.

Procedure and training already direct operators to manually back up failed automatic actuations.

185 Automate initiation of CCW flow to More reliable than manual HEP $62K $112K $56K $99K $132K >$500K Expert Panel Not Cost- Cost will exceed the RHR heat exchangers. initiation of flow to RRHR HX. Beneficial benefit.

186 Develop a procedure and obtain Backup method of removing SW02 $636K $1M $575K $879K $1.3M >$1M Expert Panel Potentially Cost Ability to do this will equipment to provide a temporary decay heat if CCW is lost. Beneficial require larger fire hookup of fire water to the RHR heat pumps exchangers to use as a backup to CCW for removing decay heat.

ULNRC-05908 September 24, 2012 Attachment 1 Page 55 of 58 Table 9-1. Callaway Plant Potentially Cost Beneficial SAMAs Callaway SAMA Number Potential Improvement Discussion Additional Discussion 29 Provide capability for Improved injection Currently being evaluated by alternate injection via capability. plant improvement program.

diesel-driven fire pump. Would use unborated water and portable pump (fire truck). Calculation of specific benefit of this SAMA was not performed since it is judged to be potentially low cost. Evaluation will consider impacts of injection of non-borated water.

64 Implement procedure and Improved ability to cool Cost based on development hardware modifications to residual heat removal heat of procedure for temporary allow manual alignment of exchangers. hookup of fire water to CCW the fire water system to the heat exchangers. Cost of component cooling water permanent modification system, or install a would be much greater.

component cooling water header cross-tie.

80 Provide a redundant train Increased availability of Procedures to open doors or or means of ventilation. components dependent on provide temporary ventilation room cooling. may be cost beneficial for the EDGs, MDAFW pumps, and charging pumps.

Procedures for opening doors to the DC switchgear rooms exist.

160 Modifications to lessen Lower impact of flood that impact of internal flooding propagates through the path through Control dumbwaiter Building dumbwaiter.

162 Install a large volume EDG Allows transfer of EDG fuel fuel oil tank at an elevation oil to the EDG day tanks greater than the EDG fuel on failure of the fuel oil oil day tanks. transfer pumps.

178 Improvements to UHS Improve availability or Implementation of temporary cooling tower electrical mitigate loss of HVAC. ventilation or opening of room HVAC. doors will be a lower cost than the calculated benefit.

ULNRC-05908 September 24, 2012 Page 56 of 58 Table 9-1. Callaway Plant Potentially Cost Beneficial SAMAs (continued) 179 Modify procedures such Prevents possible Implementation of that the water loop seals in thermally induced steam procedure change will be the RCS cold legs are not generator tube rupture lower cost than benefit, cleared following core following core damage. especially if 95% CDF damage. benefit is considered.

180 Install lower amperage Reduced fire risk. SAMA considered fuses for various 14 AWG potentially cost beneficial control circuits in the MCR. without benefit or cost The majority of the determination since the modification centers NFPA 805 license around the trip circuit fuses amendment request on NB, NG, PA, PB, and committed to performing PG system breakers. the modification.

181 Install redundant fuses and Reduced fire risk. SAMA considered isolation switches for MCR potentially cost beneficial evacuation procedure without benefit or cost OTO-ZZ-00001. determination since the NFPA 805 license amendment request committed to performing the modification.

182 To protect against multiple Reduced fire risk. SAMA considered spurious operation potentially cost beneficial scenarios, cable runs will without benefit or cost be changed to run a single determination since the wire in a protected metal NFPA 805 license jacket such that spurious amendment request valve opening due to a hot committed to performing short affecting the valve the modification.

control circuit is eliminated for the fire area. This modification will be implemented in multiple fire areas.

183 Quick response sprinkler Reduced fire risk. SAMA considered heads in cable chases A- potentially cost beneficial 11, C-30, and C-31 will be without benefit or cost modified to be in determination since the accordance with the NFPA 805 license applicable requirements of amendment request NFPA 13-1976 edition. committed to performing the modification.

186 Develop a procedure and Backup cooling water if Ability to do this will require obtain equipment to ESW/SW is lost larger fire pumps provide a temporary hookup of fire water as a replacement for ESW

ULNRC-05908 September 24, 2012 Page 57 of 58 Table 11-1. Callaway Plant Release Category Frequency Results Obtained From SAMA Cases RELEASE CATEGORY BASE NOATWS INSTAIR NOLOSP NOSLOCA CCW01 FW01 NOSGTR NOSLB CHG01 LERF-IS 1.730E-07 1.730E-07 1.730E-07 1.730E-07 1.730E-07 1.730E-07 1.730E-07 1.730E-07 1.730E-07 1.730E-07 LERF-CI 1.658E-10 1.411E-10 1.658E-10 1.422E-10 6.210E-11 1.567E-10 1.658E-10 1.658E-10 1.610E-10 1.658E-10 LERF-CF 1.125E-08 1.103E-08 1.124E-08 7.372E-09 5.378E-09 1.071E-08 1.115E-08 1.135E-08 1.116E-08 1.123E-08 LERF-SG 2.331E-06 2.306E-06 2.330E-06 2.331E-06 2.331E-06 2.331E-06 2.331E-06 0.000E+00 2.331E-06 2.331E-06 LERF-ITR 2.170E-07 1.845E-07 2.167E-07 1.309E-07 2.072E-07 2.170E-07 2.052E-07 0.000E+00 1.936E-07 2.169E-07 LATE-BMT 2.551E-06 2.268E-06 2.547E-06 1.254E-07 2.022E-06 2.507E-06 2.448E-06 2.626E-06 2.515E-06 2.467E-06 LATE-COP 3.185E-06 3.185E-06 3.185E-06 1.796E-08 3.170E-06 3.185E-06 3.185E-06 2.234E-06 3.185E-06 3.185E-06 SERF 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 INTACT 8.080E-06 8.075E-06 8.080E-06 7.065E-06 2.540E-06 7.573E-06 7.983E-06 8.119E-06 7.773E-06 8.137E-06 TOTAL 1.655E-05 1.620E-05 1.654E-05 9.851E-06 1.045E-05 1.600E-05 1.634E-05 1.316E-05 1.618E-05 1.652E-05 Table 11-1. Callaway Plant Release Category Frequency Results Obtained From SAMA Cases (Cont.)

RELEASE CATEGORY SW01 NOSBO LOCA05 H2BURN RCPLOCA LOCA 12 CONT02 LOCA04 LOCA03 CONT01 LERF-IS 1.730E-07 1.730E-07 1.730E-07 1.730E-07 1.730E-07 1.730E-07 1.730E-07 1.730E-07 1.730E-07 1.730E-07 LERF-CI 1.658E-10 1.658E-10 6.210E-11 1.658E-10 1.567E-10 1.658E-10 0.000E+00 1.658E-10 1.658E-10 1.658E-10 LERF-CF 1.124E-08 1.030E-08 5.018E-09 4.102E-12 1.048E-08 1.099E-08 1.125E-08 1.114E-08 1.089E-08 1.125E-08 LERF-SG 2.331E-06 2.329E-06 2.331E-06 2.331E-06 2.331E-06 2.331E-06 2.331E-06 2.331E-06 2.298E-06 2.331E-06 LERF-ITR 2.170E-07 1.443E-07 2.072E-07 2.170E-07 2.170E-07 2.165E-07 2.170E-07 2.170E-07 2.169E-07 2.170E-07 LATE-BMT 2.553E-06 1.611E-06 2.009E-06 2.551E-06 2.475E-06 1.893E-06 2.551E-06 2.441E-06 2.007E-06 2.551E-06 LATE-COP 3.181E-06 2.426E-06 3.170E-06 3.170E-06 3.173E-06 3.182E-06 3.185E-06 3.185E-06 3.185E-06 0.000E+00 SERF 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 INTACT 8.080E-06 7.883E-06 2.170E-06 8.080E-06 7.301E-06 8.329E-06 8.080E-06 8.080E-06 8.180E-06 8.080E-06 TOTAL 1.655E-05 1.458E-05 1.007E-05 1.652E-05 1.568E-05 1.614E-05 1.655E-05 1.644E-05 1.607E-05 1.336E-05

ULNRC-05908 September 24, 2012 Page 58 of 58 Table 11-1. Callaway Plant Release Category Frequency Results Obtained From SAMA Cases (Cont.)

RELEASE CATEGORY BREAKER DC01 SW02 CCW02 CST01 ISLOCA LOSP1 DEPRESS LOCA06 HVAC LERF-IS 1.730E-07 1.730E-07 1.730E-07 1.730E-07 1.730E-07 0.000E+00 1.730E-07 1.730E-07 1.730E-07 1.730E-07 LERF-CI 1.666E-10 1.658E-10 1.514E-10 1.422E-10 1.650E-10 1.658E-10 1.666E-10 1.658E-10 1.658E-10 1.658E-10 LERF-CF 1.129E-08 1.124E-08 9.088E-09 8.906E-09 1.112E-08 1.125E-08 1.113E-08 1.122E-08 1.109E-08 1.099E-08 LERF-SG 2.328E-06 2.331E-06 2.331E-06 2.331E-06 2.331E-06 2.331E-06 2.331E-06 2.331E-06 2.331E-06 2.329E-06 LERF-ITR 2.093E-07 2.170E-07 2.013E-07 2.108E-07 2.169E-07 2.170E-07 1.814E-07 2.160E-07 2.169E-07 1.944E-07 LATE-BMT 2.047E-06 2.551E-06 2.213E-06 1.864E-06 2.022E-06 2.551E-06 2.039E-06 2.508E-06 2.020E-06 1.657E-06 LATE-COP 3.210E-06 3.185E-06 8.964E-07 1.455E-06 3.185E-06 3.185E-06 2.991E-06 3.166E-06 3.185E-06 2.917E-06 SERF 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 INTACT 8.180E-06 8.080E-06 7.898E-06 7.836E-06 8.471E-06 8.080E-06 8.431E-06 8.069E-06 8.431E-06 8.312E-06 TOTAL 1.616E-05 1.655E-05 1.372E-05 1.388E-05 1.641E-05 1.638E-05 1.616E-05 1.647E-05 1.637E-05 1.559E-05 Table 11-1. Callaway Plant Release Category Frequency Results Obtained From SAMA Cases (Cont.)

RELEASE CATEGORY FB01 PORV EDGFUEL FW02 SW03 HVAC02 RAI7a SLIS HEP FWCCW2 LERF-IS 1.730E-07 1.730E-07 1.730E-10 1.730E-07 1.730E-07 1.730E-07 1.730E-07 1.730E-07 1.730E-07 1.730E-07 LERF-CI 1.658E-10 1.658E-10 1.658E-10 1.658E-10 1.514E-10 1.658E-10 1.658E-10 1.658E-10 1.658E-10 1.567E-10 LERF-CF 1.094E-08 1.112E-08 1.124E-08 1.047E-08 1.031E-08 1.096E-08 1.135E-08 1.123E-08 1.080E-08 1.048E-10 LERF-SG 2.326E-06 2.331E-06 2.331E-06 2.324E-06 2.331E-06 2.331E-06 2.331E-06 2.290E-06 2.329E-06 2.317E-06 LERF-ITR 1.796E-07 2.169E-07 2.169E-07 1.659E-07 2.141E-07 2.169E-07 7.508E-08 2.138E-07 2.170E-07 2.170E-07 LATE-BMT 2.006E-06 2.022E-06 2.544E-06 1.983E-06 2.428E-06 1.990E-06 2.631E-06 2.545E-06 2.523E-06 2.467E-06 LATE-COP 3.185E-06 3.185E-06 3.182E-06 3.185E-06 2.557E-06 2.823E-06 3.235E-06 3.185E-06 3.185E-06 3.174E-06 SERF 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 INTACT 8.146E-06 8.471E-06 8.078E-06 7.796E-06 7.907E-06 8.461E-06 8.119E-06 8.036E-06 7.529E-06 7.311E-06 TOTAL 1.603E-05 1.641E-05 1.636E-05 1.564E-05 1.562E-05 1.601E-05 1.658E-05 1.645E-05 1.597E-05 1.566E-05

ULNRC-05908 September 24, 2012 Page 1 of 16 Excerpts from the Callaway Level 2 Analysis, Rev. 0 Section 2.2 Containment Event Tree Structure Section 2.5 Release Categories Section 3.1 Source Term Calculations Provided with permission from ERIN Engineering and Research, Inc.

ULNRC-05908 September 24, 2012 Page 2 of 16 2.2 CONTAINMENT EVENT TREE STRUCTURE To assess the accident progression following a core damage event, this Level 2 analysis uses the containment event trees shown in Figures 2-1 & 2-2 based on the containment event trees provided in WCAP-16341-P. One event tree models station blackout scenarios, while the other models all other events. The event trees begin with one or a group of core damage sequences, then ask a number of questions to determine the type of release, if any, that occurs. Each question is modeled as a top event in the event tree and the outcome is based on previous work for Callaway, recent accident progression research, and the guidance provided in the WCAP. Each top event in the event trees is discussed below. Endstates on the event trees are discussed in Sections 2.4 and 2.5.

When implemented within the WinNUPRA model, these event trees are customized for each plant damage state, resulting in a large number of similar, but unique, containment event trees for quantification. Each unique CET is constructed by eliminating the unnecessary portions of the more general CETs, thereby maintaining the same structure and sequence labeling.

Plant Damage State Sequences This first node of each containment event tree represents the collection of all core damage sequences from the Level 1 PRA into plant damage states. Station blackout sequences are assigned to the SBO tree, while all other core damage sequences follow the non-SBO tree.

The assignment of core damage sequences to plant damage states is discussed in Section 2.3.

Containment Bypassed Level 1 PRA sequences with an unisolated, initiating steam generator tube rupture (SGTR) or an unisolated, interfacing systems LOCA (ISLOCA) will bypass containment. The analysis of ISLOCA scenarios is documented separately [6,7]. The probability of an ISLOCA is incorporated directly into the Level 2 model through basic event BI with a probability of 1.73E-07 based on that analysis.

For SGTR core damage scenarios, the analysis assumes that the steam generator relief valve will stick open once it passes superheated water with high-temperature fission products, providing a direct path to the atmosphere. SGTRs with bypass would occur if failures allow the leakage through the tube rupture to continue indefinitely. From the Callaway Level 1 analysis, SGTR core damage sequences that include successful isolation of the ruptured steam generator and successful operator actions to depressurize the RCS, cooldown the RCS, and stop the

ULNRC-05908 September 24, 2012 Page 3 of 16 safety injection will not lead to an unisolated bypass condition. SGTR sequences with such failures (including low probability event tree branches that do not question the actions) are treated as containment bypass scenarios. Subsequent CET questions can determine whether each scenario is a large and/or early release. The decision on this branch is determined by the accident sequence characteristics from the Level 1 PRA, which is indicated by the plant damage state designation.

Containment Isolated For non-bypass scenarios, the possibility of containment isolation failure exists to provide a fission product release path through containment. The existing Callaway Level 1 analysis provides the associated containment isolation system (CIS) fault trees. The Level 2 model directly incorporates the CIS fault tree model into this top event. The containment isolation system includes all potential penetration locations with pipe sizes greater than 1. Further details of the containment isolation system analysis are located in the Containment Isolation System section 3.2.19 of the IPE [8]. This top event is modeled by gate ISO-FAIL in the general event tree, and by CI-XXX, where XXX represents the individual event trees as implemented in WinNUPRA.

Reactor Coolant System Pressure High The next two top events have similar effects on accident progression, though the method by which it is achieved is different. The bottom branch of this top event, RCS Pressure High, represents core damage scenarios where the reactor coolant system is at low pressure due to a large (A) or medium (S1) loss of coolant accident or other scenarios with open relief valves that would depressurize the reactor. Low pressure means that pressure is insufficient to challenge the steam generator tubes or result in direct containment heating later in the accident progression (generally less than about 200 psi). The upper branch represents all other scenarios that will not depressurize through the break or relief valve. The decision on this branch is determined by the accident sequence characteristics from the Level 1 PRA, which is indicated by the plant damage state designation.

Steam Generator Feedwater Available Another method for reducing reactor pressure is through use of the steam generators. If feedwater is available to the steam generators, decay heat is removed and the reactor can be reduced in pressure (to around 1000 psi). This pressure reduction will eliminate the challenge to the steam generator tubes and reduce the effects of direct containment heating (which is

ULNRC-05908 September 24, 2012 Page 4 of 16 negligible for Callaway). The function of feedwater is modeled in the Level 1 PRA via both main feedwater and auxiliary feedwater and identified by the plant damage state.

Pressure-Induced Steam Generator Tube Rupture Core damage sequences that continue on the high pressure branch are assumed to be at or near the primary PORV/SRV setpoint. Without water in the steam generators, there is a possibility of pressure-induced steam generator tube rupture early in the scenario. Because the pressure is high from the beginning of the scenario, this question is asked prior to any operator actions or other reactor coolant system failures that could depressurize the RCS.

Details of this evaluation are based on WCAP-16341-P and shown in Appendix D. This event is modeled via basic event L2-SGT-VF-PISGR.

RCS Depressurize Early If the steam generator tubes survive the initial pressure differential, the operators could take action to depressurize the reactor coolant system in order to reduce the likelihood of tube rupture or direct containment heating. To do so, the operators would open a primary system PORV. If successful, the scenario transfers to a low-pressure accident progression. If the RCS is not depressurized, either due to human inaction or equipment failure, additional high-pressure failures are considered. This action appears in the plant Severe Accident Control Room Guideline Initial Response SACRG-1 [9]. This top event is modeled by gate RCS-DEP1 in the general event tree, and by RD-XXX, where XXX represents the individual event trees as implemented in WinNUPRA. The gate couples the existing system fault tree G12P100, Failure of Both PORVs, from fault tree 12PORVS with an operator action OP-XHE-FO-DEP1, Operator Fails to Open PORV to Depressurize RCS. The human error probability for this operator action is set to 0.1 consistent with Section 4.8 of the IPE [10]. The effect of the operator action is examined in the sensitivity studies.

Thermally-Induced Steam Generator Tube Rupture With the reactor coolant system remaining at high pressure and without feedwater to enough steam generators to depressurize the reactor, the likelihood of thermally-induced creep rupture of steam generator tubes is addressed. As with pressure-induced tube rupture, the age and condition of the steam generator tubes must be considered. Failure probabilities for moderately-damaged tubes are used to account for plant aging during the license renewal term. Details of this evaluation are shown in Appendix D along with the pressure-induced SGTR analysis. Basic event L2-SGT-VF-TISGR represents the probability in the model.

ULNRC-05908 September 24, 2012 Page 5 of 16 RCS Depressurize Late During high-pressure core damage scenarios, a "race" occurs to determine where the RCS will first fail. While the reactor vessel will eventually fail as the molten core degrades the lower vessel head, failures may also occur in the steam generator tubes (discussed above) or in the hot leg or surge line of the reactor coolant system. For high-pressure, station-blackout-like scenarios which tend to occur on this branch, the likelihood of hot leg failure is very high.

Based on the WCAP, this analysis uses a likelihood of 98% for hot leg failure (basic event L2-RCS-VF-DEP2). When hot leg failure occurs prior to vessel breach, the reactor coolant system depressurizes prior to failing the lower vessel head, thus eliminating the possibility of high-pressure core melt events leading to direct containment heating. This is generally a beneficial failure since it prevents direct containment heating.

Containment Failure Early Three primary causes for containment failure at the time of reactor vessel breach apply to Callaway - steam explosion, hydrogen burn, and direct containment heating. The analysis of these containment challenges follows the guidance in WCAP-16341-P. Low pressure sequences (such as due to a LOCA) reduce reactor coolant system pressure to the point where containment is only subject to steam explosion and hydrogen burn challenges. Low pressure sequences due to steam generator cooling do not depressurize as far, but likewise only consider steam explosion and hydrogen burn since the already low threat due to direct containment heating would only decrease further. High pressure sequences with depressurization after core damage due to operator action or hot leg failure are primarily subject to hydrogen burn challenges. High pressure scenarios that remain at high pressure until the time of vessel breach are primarily subject to direct containment heating challenges, which includes the effects of hydrogen combustion and steam explosion. Therefore, different branches through the event tree require different early containment failure probabilities. This model assigns probability CFE1 to the combination of steam explosion and hydrogen burn, CFE3 to direct containment heating, and CFE5 to hydrogen burn alone. Recent research has provided an improved understanding of these phenomena and each is discussed below.

Ex-vessel steam explosions due to the pouring of the molten core into a pool of water can challenge the integrity of the containment via damage to the reactor cavity. Based on WCAP-16341-P, this is a greater issue for free-standing reactor cavities (as opposed to excavated

ULNRC-05908 September 24, 2012 Page 6 of 16 cavities). Because Callaway is an excavated cavity, steam explosions do not pose a failure mechanism for early containment failure.

Hydrogen burns can challenge the integrity of the containment by creating high pressure excursions. The amount of hydrogen released into containment depends upon the amount of core damage at the time of vessel failure. Scenarios that lead to hydrogen burns at plants like Callaway are limited to about 50% zirconium oxidation for CFE5-type scenarios and 40% for CFE1-type scenarios. Based on WCAP-16341-P, the plant-specific probability of early containment failure at Callaway due to hydrogen burn is less than 0.001 at 40% oxidation and at 50% oxidation. To capture the possibility of containment failure due to hydrogen burn and/or steam explosion and maintain flexibility in the model, a probability of 0.001 will be used for both CFE1 and CFE5 in the model.

Direct containment heating is also addressed by WCAP-16341-P. The WCAP reports plant-specific conditional containment failure probabilities due to direct containment heating for several plants, including Callaway. The suggested probability is reported as 0.000 to cover all scenarios, and includes the effects of blowdown of the RCS, debris-to-gas heat transfer, exothermic metal/steam & metal/oxygen reactions, and hydrogen combustion that occur during a high-pressure melt ejection. To capture the possibility of DCH and maintain flexibility in the model, a CFE3 probability of 0.001 will be used in the model.

Containment Heat Removal Containment Heat Removal can be accomplished through either the Containment Spray System (CS) or the Containment Coolers (VN). The Level 2 PRA models the containment heat removal function via gate NO-CHR in the general event tree based on the WCAP, and by CH-XXX, where XXX represents the individual event trees as implemented in WinNUPRA. The containment heat removal function consists of a combination of gates:

  • GCS-100, Failure of CS Injection Mode, from existing system fault tree CS1
  • GCSR100, Failure of CS Recirc Mode, from existing system fault tree CSREC
  • GVN-100, Failure of VN, from existing system fault tree VN Note that for some Level 2 scenarios, these functions may not be available due to power or cooling water failures, and the system fault trees model these support systems accordingly. Failure of containment heat removal will allow the containment to slowly pressurize until failure. The plant-

ULNRC-05908 September 24, 2012 Page 7 of 16 specific MAAP calculations use a failure pressure of 134.9 psig to define containment overpressure failure [11].

No Large Early Release For accidents that bypass containment or cause a containment isolation failure, it is possible that the release may be of insufficient magnitude to be classified as a large, early release.

For steam generator tube rupture scenarios that bypass containment and lead to an early release, the operators may still be able to reduce the magnitude of the release by providing feedwater to the ruptured steam generator in order to scrub fission products from the release.

Such scrubbing should reduce the magnitude of the release such that it is no longer categorized as a large release. In the Level 2 model, this capability is included in the structure for future analysis, but is not currently credited. To credit such scrubbing as a fission product reduction mechanism, analysis would be required to include failures of secondary heat removal (i.e., feedwater to the steam generator) and human reliability analysis of the human action to keep the steam generator full. Success of the function would reduce the release to a small magnitude (non-LERF).

Note that some accidents initiated by a steam generator tube rupture may also have a relatively slow accident progression characterized by several hours between depletion of the refueling water storage tank and core uncovery. Depending on a plant's emergency response procedures, it is possible for the plant to make an anticipatory declaration of general emergency to allow more time for offsite protective actions. For SGTR sequences that do not have operable safety injection, this time delay will be much shorter, and an anticipatory declaration is not possible. At this time, no credit is taken for an anticipatory declaration in the Callaway model, but the action could be considered as an option to assess some early releases as late releases.

Containment isolation failures can also be assessed for their release magnitudes to determine whether they should be classified as LERF. Similarly to the SGTR scenarios, credit is not taken in the model for this distinction, though the Level 2 model structure does include the events to allow future evaluation if further analyses become available that support a distinction among containment isolation failures. Details of the containment isolation system analysis are located in the Containment Isolation System section 3.2.19 of the IPE [8].

ULNRC-05908 September 24, 2012 Page 8 of 16 Interfacing system LOCAs (ISLOCAs) could exist in locations that could fill with water and scrub the fission products from the release, thus providing another method of reducing a large release. However, based on the current ISLOCA analysis [6,7], such situations are not expected to occur for Callaway.

This branch of the containment event trees captures the possibility of a reduced or delayed release that would be classified as a non-LERF scenario. The Level 2 model provides for this possibility in the structure of the model, but does not credit such reductions in the current base model. The branches of the event tree are represented by basic events ISO-LG and BYP-LG.

Basemat Meltthrough If no other containment failures occur during an accident scenario and containment heat removal exists, the last containment failure mode to examine is basemat meltthrough. If not cooled by an overlying water pool, the molten corium will begin to attack and erode the concrete basemat. Several beneficial factors at Callaway make basemat meltthrough less severe than other plants. First, Callaway has a "wet" containment design. If the RWST is injected into the primary system or containment via ECCS or containment spray, the water will drain to the reactor cavity and provide cooling of the molten corium, thus reducing the chance of basemat meltthrough. Second, the Callaway containment has a very thick basemat - 10 feet thick [12]. Even without cooling of the molten corium, basemat meltthrough will require many hours to erode through this thickness of concrete. Third, Callaway has a relatively large cavity floor area, meaning the molten corium will have more space to spread, resulting in a shallow layer (less than 1 foot ) of corium which can be more easily cooled by overlying water.

For the containment event trees, sequences including injection of the RWST can avoid basemat meltthrough with a high probability of success, while sequences without injection are subject to eventual basemat meltthrough. Because basemat meltthrough is only questioned if containment heat removal is successful, a wet cavity will be maintained if it was initially wet.

The probability of having basemat meltthrough with a wet cavity is assigned a value of 0.05 (basic event L2-CNT-VF-BMMTW), based on guidance in the WCAP for a wet cavity with a shallow corium layer. For scenarios where the cavity is dry, basic event L2-CNT-VF-BMMTD models eventual basemat meltthrough with a probability of 1.0.

Core Damage Arrested Prior to Vessel Breach WCAP-16341-P provides guidance to allow incorporation of actions to recover offsite power and restore injection during station blackout scenarios. As noted in the Assumptions, this analysis

ULNRC-05908 September 24, 2012 Page 9 of 16 does not provide credit for recovery of offsite power after core damage but before a radioactive release. Given that power recovery has not occurred prior to core damage, there is a small, but non-zero chance of power recovery in the period between core damage and radioactive release. In addition, further recovery actions may be required to restore safety functions to arrest core damage and prevent a significant release. The time window available for these actions will vary for different scenarios, and therefore the slightly conservative assumption of no power recovery during this window is taken. The bottom failure branch is always followed for the Callaway Level 2 model, and is labeled in the general CET with the type of containment failure that could occur (either VB-low for low-pressure vessel breach or HPME for high-pressure melt ejection).

ULNRC-05908 September 24, 2012 Page 10 of 16 Figure 2-1 GENERAL CET FOR NON-SBO SCENARIOS

ULNRC-05908 September 24, 2012 Page 11 of 16 Figure 2-2 GENERAL CET FOR SBO SCENARIOS

ULNRC-05908 September 24, 2012 Page 12 of 16 2.5 RELEASE CATEGORIES 2.5.1 General Release Categories As indicated in the previous section, the Level 2 PRA containment event tree sequences are categorized into four general release categories, which are described below.

INTACT Containment structure and function succeed and prevent a substantial release of fission products. Source term calculations assume normal plant leakage to determine offsite consequences.

LATE Containment failure occurs, but is considered late because of a significant time delay between core damage and containment failure. Releases may be large or small, but offsite consequences are limited to latent health effects and contamination.

SERF Containment function is bypassed, but the radioactive release is scrubbed by an overlying water pool or limited by the size of the containment failure, reducing the offsite health effects.

LERF Containment failure occurs early in the scenario. Early releases are defined as those releases that occur within a short time following core damage based on plant-specific source term calculations, such that adequate evacuation time is not available to protect the public from prompt health effects. Large releases are determined by plant-specific source term calculations.

2.5.2 Detailed Release Categories A number of different Level 2 sequences contribute to each of the four general release categories above. Because the actual release characteristics will vary depending on how the containment event tree progresses, detailed release categories further define the Level 2 sequences. These detailed release categories consider the scenario characteristics and the ultimate containment failure mode.

Each Level 2 sequence is mapped into one of these detailed release categories.

INTACT

ULNRC-05908 September 24, 2012 Page 13 of 16 This release category captures all of the INTACT sequences. Because the containment is essentially intact, sequence variations have a negligible impact on the release characteristics.

INTACT-01, INTACT-02, INTACT-03, INTACT-04, and INTACT-05 contribute to this category.

Releases to the environment are via normal containment leakage.

LATE-BMT This release category captures sequences that result in basemat meltthrough. Because basemat meltthrough takes a significant amount of time to erode the thick basemat at Callaway, the release is small and significantly delayed. LATE-01, LATE-04, LATE-06, and LATE-08 contribute to this category.

LATE-COP This release category captures sequences that result in containment failure due to late overpressure. LATE-02, LATE-03, LATE-05, LATE-07, LATE-09, LATE-B, LATE-C, and LATE-D contribute to this category.

LERF-IS This release category captures sequences caused by an unisolated ISLOCA. Those sequences from LERF-09 with ISLOCA initiating events contribute to this category.

LERF-CI This release category captures sequences that result in containment isolation failure due to either valve failure or excessive pre-existing containment leakage. LERF-08 and LERF-H contribute to this release category.

LERF-CF This release category captures sequences that result in early containment failure due to steam explosion, hydrogen burn, and/or direct containment heating at the time of vessel breach. LERF-01, LERF-02, LERF-03, LERF-05, LERF-07, LERF-B, LERF-C, and LERF-E contribute to this category. Note that no credit for containment heat removal is credited as the function would not prevent containment failure, though it could affect ex-vessel cooling of the core if containment sprays fill up the reactor cavity.

LERF-SG

ULNRC-05908 September 24, 2012 Page 14 of 16 This release category captures sequences caused by a steam generator tube rupture. SGTR sequences with core damage provide a direct release path to the environment through the steam generator relief valves. Those sequences from LERF-09 with SGTR initiating events contribute to this category.

LERF-ITR This release category captures sequences that result in either a pressure-induced or thermally-induced steam generator tube rupture that bypasses containment. LERF-04, LERF-06, LERF-D, and LERF-F contribute to this category.

3.1 SOURCE TERM CALCULATIONS 3.1.1 Representative Sequence Selection For each detailed release category defined above, accident progression calculations predict the timing and amount of release. Because each release category can contain a high number of sequences, representative sequences must be defined for each category. For the INTACT, LATE, and SERF categories, the most likely contributing sequences are chosen to represent the category. For the LERF categories, both the likelihood of the scenario and its potential offsite effect is considered in order to capture the effects of all of the most likely scenarios within the category. The table below describes the representative sequences for each detailed release category. The first column includes the dominant Level 2 sequence to each release category, with the percentage of that category that the sequence contributes.

For INTACT sequences, containment structure and function succeed and prevent a large or late release of fission products. Source term calculations assume normal plant leakage to determine offsite consequences.

For LATE sequences, containment failure occurs, but is considered late because of a significant time delay between core damage and containment failure. Releases may be large or small, but offsite consequences are limited to latent health effects and contamination.

For SERF sequences, containment bypass occurs via a steam generator tube rupture, but the release is scrubbed to significantly reduce the offsite health effects.

For LERF sequences, containment failure occurs early in the scenario. Early releases are defined as those releases that occur within a short time following core damage, such that adequate evacuation time is

ULNRC-05908 September 24, 2012 Page 15 of 16 not available to protect the public from prompt health effects. The magnitude of each release is determined by a plant-specific source term calculation.

Table 3-1 REPRESENTATIVE RELEASE SCENARIOS Release Dominant Dominant Representative Sequence Category L2 Sequences L1 Sequences LERF-IS LE9:100% BI:100% Large break ISLOCA through RHR cold leg, rupture in RHR HX, ECCS success, op fail to depressurize RCS & fail to refill RWST LERF-CI LE8:62% T1S-S10:34% LOOP/SBO, AFW avail for 8 hrs, 21gpm seal LOCAs, successful initial cooldown & depressurize, fail to restore LEH:38% S2-S03:27%

power, cont isolation failure at t=0 T1TC-S02:13%

LERF-CF LEC:41% T1S-S10:34% LOOP/SBO, AFW avail for 8 hrs, 21gpm seal LOCAs, successful initial cooldown & depressurize, fail to restore LE1:24% S2-S03:22%

power, cont failure at vessel breach LE3:17% T1TC-S02:12%

LE7:11%

LERF-SG LE9:100% TSG-S07:85% SGTR, AFW to unbroken SGs, ECCS success, isolation of broken SG MSIV, op fail to cooldown/depressurize/stop SI, TSG-S09:11%

stuck-open SGRV when passing water LERF-ITR LED:49% T1S-S10:61% LOOP/SBO, AFW avail for 8 hrs, 21gpm seal LOCAs, successful initial cooldown & depressurize, fail to restore LE4:22%

power, tube rupture at core damage LEF:20%

LATE-BMT LA4:55% T1S-S03: 20% LOOP/SBO, AFW avail, 21gpm seal LOCAs, successful initial cooldown & depressurize, power restored at 8hrs, but LA1:35% T3-S06: 14%

failure of ECCS injection, CHR successful, cont failure by T2-S05: 11% basemat meltthrough TSW-S23: 11%

LATE-COP LAC:78% T1S-S10:79% LOOP/SBO, AFW avail for 8 hrs, 21gpm seal LOCAs, successful initial cooldown & depressurize, fail to restore LAD:12%

power, CHR fail due to SBO, cont failure by overpressure @

134.9 psig SERF NA* NA* Same as LERF-SG, but add AFW to ruptured SG at CD INTACT IN1:47% S2-S03: 42% S2 LOCA, AFW successful, ECCS successful, fail to recirc, no cont faiure IN5:33% T1TC-S02: 23%

IN3:17%

  • With current model, SERF does not occur, but release category is maintained for insights.

Percentage contributions based on Update 4 model.

ULNRC-05908 September 24, 2012 Page 16 of 16 Note that, in order to determine the dominant Level 1 sequences in the table above, the Level 1 eqn files were modified to add flags indicating which Level 1 sequence created each cutset.

As these propagate through the Level 2 model with the attached flags, some non-minimal cutsets may occur in the Level 2 results, leading to a very slightly conservative result. These changes are not significant enough to affect the contribution percentages recorded in the table.

ULNRC-05908 September 24, 2012 Page 1 of 14 Response to RAIs 5e and 5f Revised Tables:

Table 3-2: Level 1 Importance List Review Table 3-6: LERF Importance Review Table 3-7: Late Release Importance Review Table 3-2. Level 1 Importance List Review Associated Basic Event Name Basic Event Description RRW SAMA IE-S2 SMALL LOCA INITIATING EVENT FREQUENCY 1.554 25-42 LOSS OF OFFSITE POWER INITIATING EVENT IE-T1 FREQUENCY 1.514 1-24 OPERATOR FAILS TO ALIGN ECCS SYSTEMS FOR COLD OP-XHE-FO-ECLRS2 LEG RECIRC 1.389 36 IE-TSG STEAM GENERATOR TUBE RUPTURE IE FREQUENCY 1.166 119-129 see note on OPERATOR FAILS TO C/D AND DEPRESS THERCS AFTER operator OP-XHE-FO-SGTRDP SGTR 1.082 action events see note on OPERATOR FAILS TO C/D AND DEPRESS RCSAFTER operator OP-XHE-FO-SGTRWR WATER RELIEF 1.082 action events 26, 28-33, 36, 39, 41-46, 49-64, 70, 72, 79, 80, 82, 83,89-103, 107, 110, 149, 161, 163, 166-169, 171, 172, 175-176, 178, 179 provide mitigation of TURBINE TRIP WITH MAIN FEEDWATER AVAILABLE IE possible IE-T3 FREQ 1.07 impacts.

ULNRC-05908 September 24, 2012 Page 2 of 14 Table 3-2. Level 1 Importance List Review (continued)

BB-PRV-CC-V455A PRESSURIZER PORV PCV455A FAILS TO OPEN 1.053 89 BB-PRV-CC-V456A PRESSURIZER PORV PCV456A FAILS TO OPEN 1.053 89 NE-DGN-DR-NE01-2 DGNS CC FTR. 1.049 1-24 CHECK VALVES AEV120121,122,123 COMMON CAUSE FAIL AE-CKV-DF-V120-3 TO OPEN 1.048 163 EF-PSF-TM-ESWTNB ESW TRAIN B IN TEST OR MAINTENANCE 1.045 46-57, 62-64 OPERATOR FAILS TO RECOVER FROM A LOSSOF OP-XHE-FO-ACRECV OFFSITE POWER 1.044 22 EF-PSF-TM-ESWTNA ESW TRAIN A IN TEST OR MAINTENANCE 1.043 46-57, 62-64 PROBABILITY THAT POWER IS NOT RECOV-ERED IN 8 FAILTORECOVER-8 HOURS. 1.042 1-24 EF-MDP-DR-EFPMPS ESW PUMPS CC FTR. 1.041 46-57, 62-64 OPERATOR FAILS TO INITIATE CCW FLOW TO THE RHR OP-XHE-FO-CCWRHX HXS 1.037 185 CONDITIONAL PROB. THAT PWR IS NOT RE-COVERED IN FAILTORECOVER-12 12 HRS. 1.035 1-24 EF-MDP-FR-PEF01A ESW PUMP A (PEF01A)FAILS TO RUN 1.033 46-57, 62-64 see note on operator FB-XHE-FO-FANDB OPERATOR FAILS TO ESTABLISH RCS FEED AND BLEED 1.032 action events OPERATOR FAILS TO ALIGN ECCS SYSTEMS FOR COLD OP-XHE-FO-ECLR LEG RECIRC 1.031 36 CONDITIONAL PROB. TORNADO T(1) EVENT LOSS OF TORNADO-T1-EVENT AEPS 1.031 15 EF-MDP-FR-PEF01B ESW PUMP B (PEF01B)FAILS TO RUN 1.025 46-57, 62-64 EG-MDP-DS-EGPMP4 ALL 4 EG PUMPS CC FTS. 1.025 59 IE-S1 INTERMEDIATE LOCA INITIATING EVENT FREQUENCY 1.023 25-42 IE-TMSO MAIN STEAMLINE BREAK OUTSIDE CTMT IE FREQUENCY 1.022 153

ULNRC-05908 September 24, 2012 Page 3 of 14 Table 3-2. Level 1 Importance List Review (continued) 66, 68, 75, AL-TDP-TM-TDAFP TDAFP IN TEST OR MAINTENANCE 1.019 78 BB-RCA-WW-RCCAS TWO OR MORE RCCA'S FAIL TO INSERT (MECH. CAUSES) 1.019 130-137 ALL TRAIN B SW UNAVAIL. DUE TO DRAINAGE OF EF EF-DRAIN-TRAINB TRAIN B. 1.019 46-57, 62-64 EG-HTX-TM-CCWHXB CCW TRAIN B TEST/MAINT. (E.G. HX B TEST/MAINT.) 1.016 59 VL-ACX-DS-GL10AB ROOM COOLER SGL10A, B CC FTS 1.014 80 EF-MOV-CC-EFHV37 VALVE EFHV37 FAILS TO OPEN 1.013 46-57, 62-64 IE-S3 VERY SMALL LOCA INITIATING EVNET 1.013 25-42 NE-DGN-FR-NE0112 DIESEL GENERATOR NE01 FTR - 12 HR MT 1.013 1-24 NE-DGN-FR-NE0212 DIESEL GENERATOR NE02 FTR - 12 HR MT 1.013 1-24 NE-DGN-TM-NE01 DIESEL GENERATOR NE01 IN TEST OR MAINTENANCE 1.013 1-24 NE-DGN-TM-NE02 DIESEL GENERATOR NE02 IN TEST OR MAINTENANCE 1.013 1-24 IE-T2 LOSS OF MAIN FEEDWATER IE FREQUENCY 1.012 65-79 NE-DGN-FS-NE01 DIESEL GENERATOR NE01 FAILS TO START 1.012 1-24 66, 68, 75, AL-TDP-FS-TDAFP TDAFP FAILS TO START 1.011 78 EF-MDP-FS-PEF01A ESW PUMP A (PEF01A)FAILS TO START 1.011 46-57, 62-64 EJ-PSF-TM-EJTRNB RHR TRAIN B IN TEST OR MAINTENANCE 1.011 25-42 NE-DGN-FS-NE02 DIESEL GENERATOR NE02 FAILS TO START 1.011 1-24 EF-MDP-DS-EFPMPS ESW PUMPS CC FTS 1.01 46-57, 62-64 EF-MOV-CC-EFHV38 VALVE EFHV38 FAILS TO OPEN 1.01 46-57, 62-64 OP-XHE-FO-AEPS1 OPERATOR FAILS TO ALIGN AEPS TO NB BUS IN 1 HR 1.01 1-24 UHS C.T. ELEC. ROOM SUPPLY FAN CGD02A FAILS TO VD-FAN-FR-CGD02A RUN 1.01 178

ULNRC-05908 September 24, 2012 Page 4 of 14 Table 3-2. Level 1 Importance List Review (continued)

CHECK VALVES AEV124,125,126,127 COMMON CAUSE FAIL AE-CKV-DF-V124-7 TO OPEN 1.009 163 AEPS-ALIGN-NB02 PDG ALIGN TO NB02 (FAIL TO ALIGN PDG TO NB02) 1.009 1-24 EF-MDP-FS-PEF01B ESW PUMP B (PEF01B)FAILS TO START 1.009 46-57, 62-64 VALVES EFHV37 & 38 COMMON CAUSE FAIL TO CLOSE (2 EF-MOV-D2-V37-38 VALVES) 1.009 46-57, 62-64 see note on operator FAILTOMNLINSRODS OPERATOR FAILS TO MANUALLY DRIVE RODS INTO CORE 1.009 action events see note on OPERATORS FAIL TO DIAGNOSE RED PATH ON HEAT operator OP-COG-FRH1 SINK 1.009 action events UHS C.T. ELEC. ROOM SUPPLY FAN CGD02B FAILS TO VD-FAN-FR-CGD02B RUN 1.009 178 AEPS-ALIGN-NB01 PDG ALIGN TO NB01 (FAIL TO ALIGN PDG TO NB01) 1.008 1-24 see note on OPERATOR FAILS TO CONTROL S//G LEVEN AFTER operator AL-XHE-FO-SBOSGL COMPLEX EVENT 1.008 action events EF-MOV-OO-EFHV59 VALVE EFHV59 FAILS TO CLOSE 1.008 46-57, 62-64 EJ-PSF-TM-EJTRNA RHR TRAIN A IN TEST OR MAINTENANCE 1.008 25-42 see note on operator FAILTOREC-EFHV59 OPERATORS FAIL TO RECOVER (CLOSE) EFHV59 1.008 action events VL-ACX-FS-SGL10A ROOM COOLER FAN SGL10A FAILS TO START 1.008 80 66, 68, 75, AL-PSF-TM-ALTRNB AFW TRAIN B IN TEST OR MAINTENANCE 1.007 78 BN-TNK-FC-RWSTUA RWST UNAVAILALBE 1.007 171 54-59, 61, EG-MDP-DR-EGPMP4 ALL 4 EG PUMPS CC FTR. 1.007 63, 64 see note on OPERATOR FAILS TO START AN RHR PUMP FOR LONG operator EJ-XHE-FO-PEJ01 TERM C/D 1.007 action events

ULNRC-05908 September 24, 2012 Page 5 of 14 Table 3-2. Level 1 Importance List Review (continued)

LOSS OF ALL COMPONENT COOLING WATER IE 54-59, 61, IE-TC FREQUENCY 1.007 63, 64 IE-TSW LOSS OF SERVICE WATER INITIATING EVENT 1.007 46-57, 62-64 SA-ICC-AF-RWSTL1 NO INPUT FOR RX TRIP FROM RPS 1.007 130-137 see note on FAILURE TO RE-ESTABLISH MFW FLOW DUE TO HUMAN operator AE-XHE-FO-MFWFLO ERRORS 1.006 action events BG-MDP-FR-NCP MOTOR DRIVEN CHARGING PUMP FAILS TO RUN 1.006 25-42 EJ-MDP-DS-EJPMPS RHR PUMPS CC FAIL TO START 1.006 25-42 EJ-MOV-CC-V8811A VALVE EJHV8811A FAILS TO OPEN 1.006 25-42 FEEDLINE BREAK DOWNSTREAM OF CKVS IE IE-TFLB FREQUENCY 1.006 65-79 NF-ICC-AF-LSELSA LOAD SHEDDER TRAIN A FAILS TO SHED LOADS 1.006 1-24 see note on OPERATOR FAILS TO ISOLATE THE FAULTED S/G operator OP-XHE-FO-SGISO FOLLOWING SGTR 1.006 action events SA-ICC-AF-MSLIS NO SLIS ACTUATION SIGNAL 1.006 184 SA-ICC-AF-RWSTL4 NO RWST LOW LEVEL SIGNAL AVAILABLE (SEP GRP 4) 1.006 25-42 VL-ACX-FS-SGL10B ROOM COOLER FAN SGL10B FAILS TO START 1.006 80 VM-BDD-CC-GMD001 DAMPER GMD001 FAILS TO OPEN 1.006 80 VM-BDD-CC-GMD004 DAMPER GMD004 FAILS TO OPEN 1.006 80 VM-EHD-CC-GMTZ1A ELEC/HYDR OP DAMPER GMTZ01A FAILS TO OPEN 1.006 80 66, 68, 75, AL-MDP-FR-MDAFPB MDAFPB FAILS TO RUN AFTER START 1.005 78 66, 68, 75, AL-TDP-FR-TDAFP TDAFP FAILS TO RUN AFTER START 1.005 78 BLOWDOWN ISOLATION VALVE BMHV0001 FAILS TO 66, 68, 75, BM-AOV-OO-BMHV1 CLOSE 1.005 78 BLOWDOWN ISOLATION VALVE BMHV0004 FAILS TO 66, 68, 75, BM-AOV-OO-BMHV4 CLOSE 1.005 78

ULNRC-05908 September 24, 2012 Page 6 of 14 Table 3-2. Level 1 Importance List Review (continued)

EJ-MOV-CC-V8811B VALVE EJHV8811B FAILS TO OPEN 1.005 25-42 EJ-MOV-D2-8811AB VALVES EJHV8811A & B COMMON CAUSE FAIL TO OPEN 1.005 25-42 NE-DGN-FR-NE01-2 DGN NE01 FAILS TO RUN (1 HR MISSION TIME) 1.005 1-24 NF-ICC-AF-LSELSB LOAD SHEDDER TRAIN B FAILS TO SHED LOADS 1.005 1-24 VM-BDD-CC-GMD006 DAMPER GMD006 FAILS TO OPEN 1.005 80 VM-BDD-CC-GMD009 DAMPER GMD009 FAILS TO OPEN 1.005 80 VM-EHD-CC-GMTZ11 ELEC/HYDR OP DAMPER GMTZ11A FAILS TO OPEN 1.005 80 RCS = reactor coolant system; IE = initiating event; CC = common cause; FTR = fail to run; ESW = essential service water; ECCS = emergency core cooling system; FTS = fail to start Note 1 - The current plant procedures and training meet current industry standards. There are no additional specific procedure improvements that could be identified that would affect the result of the HEP calculations. Therefore, no SAMA items were added to the plant specific list of SAMAs as a result of the human actions on the list of basic events with RRW greater than 1.005.

ULNRC-05908 September 24, 2012 Page 7 of 14 Table 3-6. LERF Importance Review Associated Basic Event Name Basic Event Description RRW SAMA IE-TSG STEAM GENERATOR TUBE RUPTURE IE FREQUENCY 6.808 119-129 See note on OPERATOR FAILS TO C/D AND DEPRESS THERCS operator OP-XHE-FO-SGTRDP AFTER SGTR 1.835 action events See note on OP-XHE-FO- OPERATOR FAILS TO C/D AND DEPRESS RCSAFTER operator SGTRWR WATER RELIEF 1.835 action events BB-PRV-CC-V455A PRESSURIZER PORV PCV455A FAILS TO OPEN 1.314 161 BB-PRV-CC-V456A PRESSURIZER PORV PCV456A FAILS TO OPEN 1.314 161 BI ISLOCA CDF 1.068 111-113 See note on OPERATOR FAILS TO ISOLATE THE FAULTEDS/G operator OP-XHE-FO-SGISO FOLLOWING SGTR 1.037 action events LOSS OF OFFSITE POWER INITIATING EVENT IE-T1 FREQUENCY 1.034 1-24 26, 28-33, 36, 39, 41-46, 49-64, 70, 72, 79, 80, 82, 83,89-103, 107, 110, 149, 161, 163, 166-169, 171, 172, 175-176, 178, 179 provide mitigation of TURBINE TRIP WITH MAIN FEEDWATER AVAILABLE IE possible IE-T3 FREQ 1.028 impacts.

S/G PORVS ABPV01, 02, 03, & 04 COMMONCAUSE FAIL AB-ARV-DF-SGPRVS TO OPEN 1.024 89 S/G PORV ABPV0003 ISOLATED FOR AB-ARV-TM-ABPV03 TEST/MAINTENANCE 1.024 89 SAMA 36, see note on OPERATOR FAILS TO ESTABLISH RCS FEED AND operator FB-XHE-FO-FANDB BLEED 1.023 action events

ULNRC-05908 September 24, 2012 Page 8 of 14 Table 3-6. LERF Importance Review (continued)

CHECK VALVES AEV120121,122,123 COMMON CAUSE AE-CKV-DF-V120-3 FAIL TO OPEN 1.022 163 S/G PORV ABPV0001 ISOLATED FOR AB-ARV-TM-ABPV01 TEST/MAINTENANCE 1.02 89 TWO (2) OR MORE RCCA's FAIL TO IN- SERT (MECH.

BB-RCA-WW-RCCAS CAUSES) 1.02 130-137 SA-ICC-AF-MSLIS NO SLIS ACTUATION SIGNAL 1.016 184 S/G PORV ABPV0004 ISOLATED FOR AB-ARV-TM-ABPV04 TEST/MAINTENANCE 1.015 89 AB-PHV-OO-ABHV17 MSIV "B" (AB-HV-17) FAILS TO CLOSE ON DEMAND 1.015 89 CONDITIONAL PROB. TORNADO T(1) EVENT LOSS OF TORNADO-T1-EVENT AEPS 1.014 15 BB-RLY-FT-72455 72 RELAY FAILS TO TRANSFER 1.011 79 BB-RLY-FT-72456 72 RELAY FAILS TO TRANSFER 1.011 79 BB-RLY-FT-AR455 AUX. RELAY FAILS TO TRANSFER 1.011 79 BB-RLY-FT-AR456 AUX. RELAY FAILS TO TRANSFER 1.011 79 NE-DGN-DR-NE01-2 DGNS CC FTR. 1.01 1-24 AB-ARV-CC-ABPV04 S/G PORV ASPV0004 FAILS TO OPEN 1.009 89 VL-ACX-DS-GL10AB ROOM COOLER SGL10A, B CC FTS 1.009 80 AB-ARV-CC-ABPV01 S/G PORV ASPV0001 FAILS TO OPEN 1.008 89 See note on FAILURE TO RE-ESTABLISH MFW FLOW DUE TO operator AE-XHE-FO-MFWFLO HUMAN ERRORS 1.008 action events AL-TDP-TM-TDAFP TDAFP IN TEST OR MAINTENANCE 1.008 66, 68, 75, 78 MAIN STEAMLINE BREAK OUTSIDE CTMT IE IE-TMSO FREQUENCY 1.008 153 AB-ARV-CC-ABPV03 S/G PORV ASPV0003 FAILS TO OPEN 1.007 89 NE-DGN-FR-NE0112 DIESEL GENERATOR NE01 FTR - 12 HR MT 1.007 1-24

ULNRC-05908 September 24, 2012 Page 9 of 14 Table 3-6. LERF Importance Review (continued)

NE-DGN-FR-NE0212 DIESEL GENERATOR NE02 FTR - 12 HR MT 1.007 1-24 EJ-PSF-TM-EJTRNB RHR TRAIN B IN TEST OR MAINTENANCE 1.006 25-42 See note on OPERATOR FAILS TO PERFORM C/D TO COLD S/D IAW operator OP-XHE-FO-ECA32 ECA 3.2 1.006 action events AB-AOV-CC-ABUV34 STEAM DUMP ABUV0034 FAILS TO OPEN 1.005 89 AB-AOV-CC-ABUV35 STEAM DUMP ABUV0035 FAILS TO OPEN 1.005 89 AB-AOV-CC-ABUV36 STEAM DUMP ABUV0036 FAILS TO OPEN 1.005 89 See note on OPERATOR FAILS TO CONTROL S//G LEVEN AFTER operator AL-XHE-FO-SBOSGL COMPLEX EVENT 1.005 action events See note on OPERATOR FAILS TO START AN RHR PUMP FOR LONG operator EJ-XHE-FO-PEJ01 TERM C/D 1.005 action events OPERATOR FAILS TO MANUALLY DRIVE RODS INTO FAILTOMNLINSRODS CORE 1.005 130-137 ISLOCA = interfacing system LOCA; S/G = steam generator Note 1 - The current plant procedures and training meet current industry standards. There are no additional specific procedure improvements that could be identified that would affect the result of the HEP calculations. Therefore, no SAMA items were added to the plant specific list of SAMAs as a result of the human actions on the list of basic events with RRW greater than 1.005.

ULNRC-05908 September 24, 2012 Page 10 of 14 Table 3-7. Late Release Importance Review Associated Basic Event Name Basic Event Description RRW SAMA LOSS OF OFFSITE POWER INITIATING EVENT IE-T1 FREQUENCY 4.51 1-24 RECOVERY POWER AND SW IN 8 HRS BEFORE CORE RECSWT1 UNCVRED 1.474 1-24 SAMA 22, see note on OPERATOR FAILS TO RECOVER FROM A LOSSOF operator OP-XHE-FO-ACRECV OFFSITE POWER 1.14 action events EF-PSF-TM-ESWTNB ESW TRAIN B IN TEST OR MAINTENANCE 1.136 46-57, 62-64 NE-DGN-DR-NE01-2 DGNS CC FTR. 1.133 1-24 EF-MDP-DR-EFPMPS ESW PUMPS CC FTR. 1.129 46-57, 62-64 EF-PSF-TM-ESWTNA ESW TRAIN A IN TEST OR MAINTENANCE 1.127 46-57, 62-64 PROBABILITY THAT POWER IS NOT RECOV-ERED IN 8 FAILTORECOVER-8 HOURS. 1.105 1-24 CONDITIONAL PROB. THAT PWR IS NOT RE-COVERED FAILTORECOVER-12 IN 12 HRS. 1.098 1-24 26, 28-33, 36, 39, 41-46, 49-64, 70, 72, 79, 80, 82, 83,89-103, 107, 110, 149, 161, 163, 166-169, 171, 172, 175-176, 178, 179 provide mitigation of TURBINE TRIP WITH MAIN FEEDWATER AVAILABLE IE possible IE-T3 FREQ 1.088 impacts.

EF-MDP-FR-PEF01A ESW PUMP A (PEF01A)FAILS TO RUN 1.085 46-57, 62-64

ULNRC-05908 September 24, 2012 Page 11 of 14 Table 3-7. Late Release Importance Review (continued)

SAMA 36, see note on OPERATOR FAILS TO ESTABLISH RCS FEED AND operator FB-XHE-FO-FANDB BLEED 1.076 action events EF-MDP-FR-PEF01B ESW PUMP B (PEF01B)FAILS TO RUN 1.074 46-57, 62-64 CONDITIONAL PROB. TORNADO T(1) EVENT LOSS OF TORNADO-T1-EVENT TEMP EDGS 1.073 1-24 IE-S2 SMALL LOCA INITIATING EVENT FREQUENCY 1.067 25-42 CHECK VALVES AEV120121,122,123 COMMON CAUSE AE-CKV-DF-V120-3 FAIL TO OPEN 1.05 163 TWO (2) OR MORE RCCA's FAIL TO IN- SERT (MECH.

BB-RCA-WW-RCCAS CAUSES) 1.048 130-137 SAMA 36, see note on OPERATOR FAILS TO ALIGN ECCS SYSTEMS FOR operator OP-XHE-FO-ECLRS2 COLD LEG RECIRC 1.042 action events ALL TRAIN B SW UN- AVAIL. DUE TO DRAINAGE OF EF EF-DRAIN-TRAINB TRAIN B. 1.036 46-57, 62-64 NE-DGN-TM-NE02 DIESEL GEN NE02 IN TEST OR MAINTENANCE 1.034 1-24 NE-DGN-FR-NE0112 DIESEL GENERATOR NE01 FTR - 12HR MT 1.033 1-24 EF-MOV-CC-EFHV37 VALVE EFHV37 FAILS TO OPEN 1.032 46-57, 62-64 IE-S3 VERY SMALL LOCA INITIATING EVENT FREQUENCY 1.032 25-42 NE-DGN-FR-NE0212 DIESEL GENERATOR NE02 FTR - 12HR MT 1.032 1-24 NE-DGN-TM-NE01 DIESEL GEN NE01 IN TEST OR MAINTENANCE 1.032 1-24 NE-DGN-FS-NE01 DIESEL GENERATOR NE01 FAILS TO START 1.03 1-24 CONDITIONAL PROB. T(1) EVENT NOT CAUSED BY NON-TORNADO-T1 TORNADO 1.03 1-24 UHS C.T. ELEC. ROOMSUPPLY FAN CGD02A FAILS TO VD-FAN-FR-CGD02A RUN 1.03 178

ULNRC-05908 September 24, 2012 Page 12 of 14 Table 3-7. Late Release Importance Review (continued)

NE-DGN-FS-NE02 DIESEL GENERATOR NE02 FAILS TO START 1.029 1-24 See note on operator OP-XHE-FO-DEP1 Operator Fails to Open PORV to Depressurize RCS 1.029 action events EF-MDP-DS-EFPMPS ESW PUMPS CC FTS. 1.028 46-57, 62-64 EF-MOV-CC-EFHV38 VALVE EFHV38 FAILS TO OPEN 1.028 46-57, 62-64 EF-MDP-FS-PEF01A ESW PUMP A (PEF01A)FAILS TO START 1.027 46-57, 62-64 EF-MDP-FS-PEF01B ESW PUMP B (PEF01B)FAILS TO START 1.027 46-57, 62-64 EF-MOV-D2-V37-38 COMMON CAUSE FAIL.-VALVES EF-HV-37 AND38 FTC. 1.027 46-57, 62-64 UHS C.T. ELEC. ROOMSUPPLY FAN CGD02B FAILS TO VD-FAN-FR-CGD02B RUN 1.026 178 See note on operator OP-XHE-FO-AEPS1 OPERATOR FAIL TO ALIGN AEPS TO NB BUS IN 1 HR 1.025 action events OPERATOR FAILS TO MANUALLY DRIVE RODSINTO FAILTOMNLINSRODS CORE (RI). 1.023 130-137 EF-MOV-OO-EFHV59 VALVE EFHV59 FAILS TO CLOSE 1.022 46-57, 62-64 See note on operator FAILTOREC-EFHV59 OPERATORS FAIL TO RECOVER (CLOSE) EFHV59. 1.022 action events BN-TNK-FC-RWSTUA RWST UNAVAILABLE 1.02 171 AEPS-ALIGN-NB01 PDG ALIGN TO NB01 (FAIL TO ALIGN PDG TO NB01) 1.016 1-24 AEPS-ALIGN-NB02 PDG ALIGN TO NB02 (FAIL TO ALIGN PDG TO NB02) 1.015 1-24 AL-TDP-TM-TDAFP TDAFP IN TEST OR MAINTENANCE 1.015 66, 68, 75, 78 IE-T2 LOSS OF MAIN FEEDWATER IE FREQUENCY 1.013 65-79 NF-ICC-AF-LSELSA LOAD SHEDDER TRAIN A FAILS TO SHED LOADS 1.013 1-24

ULNRC-05908 September 24, 2012 Page 13 of 14 Table 3-7. Late Release Importance Review (continued)

NF-ICC-AF-LSELSB LOAD SHEDDER TRAIN B FAILS TO SHED LOADS 1.013 1-29 VM-BDD-CC-GMD001 DAMPER GMD001 FAILS TO OPEN 1.013 80 VM-BDD-CC-GMD004 DAMPER GMD004 FAILS TO OPEN 1.013 80 VM-BDD-CC-GMD006 DAMPER GMD006 FAILS TO OPEN 1.013 80 VM-BDD-CC-GMD009 DAMPER GMD009 FAILS TO OPEN 1.013 80 VM-EHD-CC-GMTZ11 ELEC/HYDR OP DAMPER GMTZ11A FAILS TO OPEN 1.013 80 VM-EHD-CC-GMTZ1A ELEC/HYDR OP DAMPER GMTZ01A FAILS TO OPEN 1.013 80 NE-DGN-FR-NE01-2 DGN NE02 FAILS TO RUN (1 HR MISSION TIME) 1.012 1-24 NE-DGN-FR-NE02-2 DGN NE02 FAILS TO RUN (1 HR MISSION TIME) 1.011 1-24 CHECK VALVES EFV001 AND EFV004 COMMON CAUSE EF-CKV-DF-V01-04 FAIL TO OPEN 1.009 46-57, 62-64 OPERATORS MANUALLY DRIVE RODS INTO THE MANLRODINSERTION CORE 1.009 130-137 VM-FAN-FS-CGM01A DIESEL GEN SUPPLY FAN CGM01A FAILS TO START 1.009 80 VM-FAN-FS-CGM01B DIESEL GEN SUPPLY FAN CGM01B FAILS TO START 1.009 80 CHECK VALVES AEV124,125,126,127 COMMON CAUSE AE-CKV-DF-V124-7 FAIL TO OPEN 1.008 163 See note on FAILURE TO RE-ESTABLISH MFW FLOW DUE TO operator AE-XHE-FO-MFWFLO HUMAN ERRORS 1.008 action events COMMON CAUSE FAILURE EG-TV-29 AND 30 TO EG-AOV-DF-TV2930 CLOSE 1.008 46-57, 62-64 EG-HTX-TM-CCWHXB CCW TRAIN B TEST/MAINT. (E.G. HX B TEST/MAINT.) 1.008 46-57, 62-64 FEEDLINE BREAK DOWNSTREAM OF CKVS IE IE-TFLB FREQUENCY 1.008 65-79 AL-TDP-FS-TDAFP TDAFP FAILS TO START 1.007 66, 68, 75, 78 See note on OPERATOR FAILS TO CONTROL S//G LEVEN AFTER operator AL-XHE-FO-SBOSGL COMPLEX EVENT 1.007 action events

ULNRC-05908 September 24, 2012 Page 14 of 14 Table 3-7. Late Release Importance Review (continued)

IE-TSW LOSS OF SERVICE WATER INITIATING EVENT 1.007 46-57, 62-64 NB-BKR-CC-NB0112 BREAKER NB0112 FAILS TO OPEN 1.007 1-24 NE-DGN-DS-NE01-2 DGNS CC FTS. 1.007 1-24 BG-MDP-TM-CCPA CCP A IN TEST OR MAINTENANCE 1.006 25-42 BG-MDP-TM-CCPB CCP B IN TEST OR MAINTENANCE 1.006 25-42 EG-MDP-DS-EGPMP4 ALL 4 EG PUMPS CC FTS. 1.006 25-42 MAIN STEAMLINE BREAK OUTSIDE CTMT IE IE-TMSO FREQUENCY 1.006 153 NB-BKR-CC-NB0209 BREAKER NB0209 FAILS TO OPEN 1.006 1-24 UHS C.T. ELEC. ROOMSUPPLY FAN CGD02A FAILS TO VD-FAN-FS-CGD02A START 1.006 178 LOSS OF VITAL DC BUS NK01 INITIATING EVENT IE-TDCNK01 FREQUENCY 1.005 3, 5, 6, 7, OPERATOR FAILS TO INITIATE CCW FLOW TO THE OP-XHE-FO-CCWRHX RHR HXS 1.005 185 See note on OPERATOR FAILS TO START AND ALIGN ESW 2 HR operator OP-XHE-FO-ESW2HR AFTER SW LOSS 1.005 action events VD-FAN-DR-GD02AB FANS CGD02A,B COMMON CAUSE FTS 1.005 178 UHS C.T. ELEC. ROOMSUPPLY FAN CGD02B FAILS TO VD-FAN-FS-CGD02B START 1.005 178 VM-FAN-DS-GMFANS FANS CGM01A,B COMMON CAUSE FTS 1.005 178 UHS = ultimate heat sink; AEPS = alternate emergency power system; RWST = refueling water storage tank Note 1 - The current plant procedures and training meet current industry standards. There are no additional specific procedure improvements that could be identified that would affect the result of the HEP calculations. Therefore, no SAMA items were added to the plant specific list of SAMAs as a result of the human actions on the list of basic events with RRW greater than 1.005.

ULNRC-05908 September 24, 2012 Page 1 of 8 CALLAWAY PLANT UNIT 1 LICENSE RENEWAL APPLICATION REQUEST FOR ADDITIONAL INFORMATION Callaway Level 2 Analysis, Appendix E Provided with permission from ERIN Engineering and Research, Inc.

ULNRC-05908 September 24, 2012 Page 2 of 8 SR CATEGORY_II ROADMAP LE-A1 IDENTIFY those physical characteristics at the time of core damage that can influence Section 2.3, Plant Damage LERF. Examples include (a) RCS pressure (high RCS pressure can result in high States pressure melt ejection) (b) status of emergency core coolant systems (failure in injection can result in a dry cavity and extensive Core Concrete Interaction) (c) status of containment isolation (failure of isolation can result in an unscrubbed release) (d) status of containment heat removal (e) containment integrity (e.g., vented, bypassed, or failed) (f) steam generator pressure and water level (PWRs) (g) status of containment inerting (BWRs)

LE-A2 IDENTIFY the accident sequence characteristics that lead to the physical characteristics Section 2.2, 2.3, & CET identified in LE-A1. Examples include (a) type of initiator (1) Transients can result in high RCS pressure (2) LOCAs usually result in lower RCS pressure (3) ISLOCAs, SGTRs can result in containment bypass (b) status of electric power: loss of electric power can result in loss of ECC injection (c) status of containment safety systems such as sprays, fan coolers, igniters, or venting systems: operability of containment safety systems determines status of containment heat removal. The references in Notes (1) and (2) provide example lists of typical characteristics.

LE-A3 IDENTIFY how the physical characteristics identified in LE-A1 and the accident Section 2.2 & CET sequence characteristics identified in LE-A2 are addressed in the LERF analysis. For example (a) which characteristics are addressed in the Level 1 event trees (b) which characteristics, if any, are addressed in bridge trees (c) which characteristics, if any, are addressed in the containment event trees. JUSTIFY any characteristics identified in LE-A1 or LE-A2 that are excluded from the LERF analysis.

LE-A4 PROVIDE a method to explicitly account for the LE-A1 and LE-A2 characteristics and Integrated model, section ensure that dependencies between the Level 1 and Level 2 models are properly 2.3 treated. Examples include: treatment in Level 2, expanding Level 1, construction of a bridge tree, transfer of the information via PDS, or a combination of these.

LE-A5 DEFINE plant damage states consistent with LE-A1, LE-A2, LE-A3, and LE-A4. Section 2.3 LE-B1 IDENTIFY LERF contributors from the set identified in Table 2-2.8-3. INCLUDE as Section 2.2 appropriate, unique plant issues as determined by expert judgment and/or engineering analyses.

ULNRC-05908 September 24, 2012 Page 3 of 8 SR CATEGORY_II ROADMAP LE-B2 DETERMINE the containment challenges (e.g., temperature, pressure loads, debris Section 2.2 subsections on impingement) resulting from contributors identified in LE-B1 using applicable generic or Containment Failure at plant-specific analyses for significant containment challenges. USE conservative Vessel Breach &

treatment or a combination of conservative and realistic treatment for non-significant Containment Heat Removal containment challenges. If generic calculations are used in support of the assessment, Fails JUSTIFY applicability to the plant being evaluated.

LE-B3 UTILIZE supporting engineering analyses in accordance with the applicable Success criteria based on requirements of Table 2-2.3-2(b). system notebooks for containment systems, which provide SC basis.

LE-C1 DEVELOP accident sequences to a level of detail to account for the potential Section 2.2 subsection on contributors identified in LE-B1 and analyzed in LE-B2. Compare the containment Containment Failure at challenges analyzed in LE-B with the containment structural capability analyzed in LE-D Vessel Breach, CET, and identify accident progressions that have the potential for a large early release. Section 2.4 - Level 2 JUSTIFY any generic or plant-specific calculations or references used to categorize Sequences, Section 2.5 -

releases as non-LERF contributors based on release magnitude or timing. NUREG/CR- Release Categories 6595, App. A provides a discussion and examples of LERF source terms.

LE-C2 INCLUDE realistic treatment of feasible operator actions following the onset of core Section 2.2 subsections damage consistent with applicable procedures, e.g., EOPs/SAMGs, proceduralized RCS Depressurize Early; actions, or Technical Support Center guidance. Section 3.2.5 - Sensitivity Studies LE-C3 REVIEW significant accident progression sequences resulting in a large early release to Section 3.2.4 determine if repair of equipment can be credited. JUSTIFY credit given for repair [i.e.,

ensure that plant conditions do not preclude repair and actuarial data exists from which to estimate the repair failure probability (see SY-A24, DA-C15, and DA-D8)]. AC power recovery based on generic data applicable to the plant is acceptable.

ULNRC-05908 September 24, 2012 Page 4 of 8 SR CATEGORY_II ROADMAP LE-C4 INCLUDE model logic necessary to provide a realistic estimation of the significant Section 2.2, CET, Section accident progression sequences resulting in a large early release. INCLUDE mitigating 2.4 - Level 2 Sequences, actions by operating staff, effect of fission product scrubbing on radionuclide release, fission product scrubbing in and expected beneficial failures in significant accident progression sequences. MAAP as appropriate, PROVIDE technical justification (by plant-specific or applicable generic calculations beneficial failures by e.g.,

demonstrating the feasibility of the actions, scrubbing mechanisms, or beneficial LOCAs that depressurize failures) supporting the inclusion of any of these features.

LE-C5 USE appropriate realistic generic or plant-specific analyses for system success criteria System success criteria in for the significant accident progression sequences. USE conservative or a combination system notebooks of conservative and realistic system success criteria for non-risk significant accident progression sequences.

LE-C6 DEVELOP system models that support the accident progression analysis in a manner Existing system models for consistent with the applicable requirements for 2-2.4, as appropriate for the level of CS, VN, CIS detail of the analysis.

LE-C7 In crediting HFEs that support the accident progression analysis, USE the applicable Conservative treatment of requirements of 2-2.5, as appropriate for the level of detail of the analysis. HFE, with sensitivity study LE-C8 INCLUDE accident sequence dependencies in the accident progression sequences in a Integrated model, section manner consistent with the applicable requirements of para. 2-2.2, as appropriate for 2.3 the level of detail of the analysis.

LE-C9 JUSTIFY any credit given for equipment survivability or human actions under adverse Section 3.2.4 environments.

LE-C10 REVIEW significant accident progression sequences resulting in a large early release to Section 3.2.4 determine if engineering analyses can support continued equipment operation or operator actions during accident progression that could reduce LERF. USE conservative or a combination of conservative and realistic treatment for nonsignificant accident progression sequences.

LE-C11 JUSTIFY any credit given for equipment survivability or human actions that could be Section 3.2.4 impacted by containment failure.

ULNRC-05908 September 24, 2012 Page 5 of 8 SR CATEGORY_II ROADMAP LE-C12 REVIEW significant accident progression sequences resulting in a large early release to Section 3.2.4 determine if engineering analyses can support continued equipment operation or operator actions after containment failure that could reduce LERF. USE conservative or a combination of conservative and realistic treatment for non-significant accident progression sequences.

LE-C13 PERFORM a containment bypass analysis in a realistic manner. JUSTIFY any credit Section 2.2 subsection on taken for scrubbing (i.e., provide an engineering basis for the decontamination factor No Large Early Release, used). MAAP model for SGTR with scrubbing LE-D1 DETERMINE the containment ultimate capacity for the containment challenges that Section 2.2 subsections on result in a large early release. PERFORM a realistic containment capacity analysis for Containment Failure Early the significant containment challenges. USE a conservative or a combination of & Containment Heat conservative and realistic evaluation of containment capacity for non-significant Removal, based on plant-containment challenges. If generic calculations are used in support of the assessment, specific values of WCAP JUSTIFY applicability to the plant being evaluated. Analyses may consider use of similar containment designs or estimating containment capacity based on design pressure and a realistic multiplier relating containment design pressure and median ultimate failure pressure. Quasi-static containment capability evaluations are acceptable unless hydrogen concentrations are expected to result in potential detonations. Such considerations need to be included for small volume containments, such as the ice condenser type.

LE-D2 EVALUATE the impact of containment seals, penetrations, hatches, drywell heads Covered by IPE Section (BWRs), and vent pipe bellows and INCLUDE as potential containment challenges, as 4.1.1, Containment required. If generic analyses are used in support of the assessment, JUSTIFY Structure and Systems, applicability to the plant being evaluated. subsection Containment Isolation LE-D3 When containment failure location affects the event classification of the accident NA - Failure location does progression as a large early release, DEFINE failure location based on a realistic not affect classification of containment assessment that accounts for plant-specific features. If generic analyses early failures are used in support of the assessment, JUSTIFY applicability to the plant being evaluated.

ULNRC-05908 September 24, 2012 Page 6 of 8 SR CATEGORY_II ROADMAP LE-D4 PERFORM a realistic interfacing system failure probability analysis for the significant See ISLOCA References accident progression sequences resulting in a large early release. USE a conservative or a combination of conservative and realistic evaluation of interfacing system failure probability for nonsignificant accident progression sequences resulting in a large early release. INCLUDE behavior of piping relief valves, pump seals, and heat exchangers at applicable temperature and pressure conditions.

LE-D5 PERFORM a realistic secondary side isolation capability analysis for the significant Section 2.2, 2.3, CET accident progression sequences caused by SG tube failure resulting in a large early realistically address release. USE a conservative or a combination of conservative and realistic evaluation SGTRs, binning into of secondary side isolation capability for nonsignificant accident progression sequences appropriate PDSs, resulting in a large early release. JUSTIFY applicability to the plant being evaluated. sensitivities for scrubbing Analyses may consider realistic comparison with similar isolation capability in similar and late releases containment designs.

LE-D6 PERFORM an analysis of thermally-induced SG tube rupture that includes plant-specific Appendix D procedures and design features and conditions that could impact tube failure. An acceptable approach is one that arrives at plant-specific split fractions by selecting the SG tube conditional failure probabilities based on NUREG-1570 or similar evaluation for induced SG failure of similarly designed SGs and loop piping. SELECT failure probabilities based on (a) RCS and SG post-accident conditions sufficient to describe the important risk outcomes (b) secondary side conditions including plant-specific treatment of MSSV and ADV failures. JUSTIFY assumptions and selection of key inputs.

An acceptable justification can be obtained by the extrapolation of the information in NUREG-1570 to obtain plant-specific models, use of reasonably bounding assumptions, or performance of sensitivity studies indicating low sensitivity to changes in the range in question.

LE-D7 PERFORM containment isolation analysis in a realistic manner for the significant See CIS system notebook /

accident progression sequences resulting in a large early release. USE conservative or IPE a combination of conservative or realistic treatment for the non-significant accident progression sequences resulting in a large early release. INCLUDE consideration of both the failure of containment isolation systems to perform properly and the status of safety systems that do not have automatic isolation provisions.

ULNRC-05908 September 24, 2012 Page 7 of 8 SR CATEGORY_II ROADMAP LE-E1 SELECT parameter values for equipment and operator response in the accident Equipment and operator progression analysis in a manner consistent with the applicable requirements of 2-2.5 parameters consistent with and 2-2.6 including consideration of the severe accident plant conditions, as Level 1 approach appropriate for the level of detail of the analysis.

LE-E2 USE realistic parameter estimates to characterize accident progression phenomena for Phenomena values based significant accident progression sequences resulting in a large early release. USE on plant-specific values, conservative or a combination of conservative and realistic estimates for non- WCAP significant accident progression sequences resulting in a large early release.

LE-E3 INCLUDE as LERF contributors potential large early release (LER) sequences identified Section 2.5 from the results of the accident progression analysis of LE-C except those LER sequences justified as non-LERF contributors in LE-C1.

LE-E4 QUANTIFY LERF in a manner consistent with the applicable requirements of Tables 2- Section 3.2 2.7-2(a), 2-2.7-2(b), and 2-2.7-2(c).

LE-F1 PERFORM a quantitative evaluation of the relative contribution to LERF from plant Section 3.2 damage states and significant LERF contributors from Table 2-2.8-3.

LE-F2 REVIEW contributors for reasonableness (e.g., to assure excessive conservatisms have Section 3.2.4 not skewed the results, level of plant specificity is appropriate for significant contributors, etc.).

LE-F3 IDENTIFY and CHARACTERIZE the LERF sources of model uncertainty and related Section 3.2 assumptions, in a manner consistent with the applicable requirements of Tables 2-2.7-2(d) and 2-2.7-2(e).

LE-G1 DOCUMENT the LERF analysis in a manner that facilitates PRA applications, upgrades, Entire Level 2 Report and peer review.

ULNRC-05908 September 24, 2012 Page 8 of 8 SR CATEGORY_II ROADMAP LE-G2 DOCUMENT the process used to identify plant damage states and accident progression Section 2 contributors, define accident progression sequences, evaluate accident progression analyses of containment capability, and quantify and review the LERF results. For example, this documentation typically includes (a) the plant damage states and their attributes, as used in the analysis (b) the method used to bin the accident sequences into plant damage states (c) the containment failure modes, phenomena, equipment failures and human actions considered in the development of the accident progression sequences and the justification for their inclusion or exclusion from the accident progression analysis (d) the treatment of factors influencing containment challenges and containment capability, as appropriate for the level of detail of the analysis (e) the basis for the containment capacity analysis including the identification of containment failure location(s), if applicable (f) the accident progression analysis sequences considered in the containment event trees (g) the basis for parameter estimates (h) the model integration process including the results of the quantification including uncertainty and sensitivity analyses, as appropriate for the level of detail of the analysis.

LE-G3 DOCUMENT the relative contribution of contributors (i.e., plant damage states, accident Section 3.2 progression sequences, phenomena, containment challenges, containment failure modes) to LERF.

LE-G4 DOCUMENT the sources of model uncertainty and related assumptions (as identified in Assumptions in Section LE-F3) associated with the LERF analysis, including results and important insights from 2.1; Key uncertainties in sensitivity studies. Section 3.2.5 LE-G5 IDENTIFY limitations in the LERF analysis that would impact applications. Section 3.2.1 LE-G6 DOCUMENT the quantitative definition used for significant accident progression Section 3.2.4 sequence. If other than the definition used in Section 2, JUSTIFY the alternative.