Text
Enclosure 9 to ULNRC-06696 Page 1 of 94 to ULNRC-06696 ARCON96-NAI Input Run Specifications (94 pages) to ULNRC-06696 Page 2 of 94 Table of Contents clwA96_01.RSF: Stack/Plant Vent to 'A' CB intake (Emergency).................................................................................................................................. 6 clwA96_02.RSF: Stack/Plant Vent to 'B' CB intake (Emergency).................................................................................................................................. 7 clwA96_03.RSF: Stack/Plant Vent to Midpoint between Intakes................................................................................................................................. 8 clwA96_04.RSF: RWST to 'A' CB intake (Emergency).................................................................................................................................................... 9 clwA96_05.RSF: RWST to 'B' CB intake (Emergency).................................................................................................................................................. 10 clwA96_06.RSF: RWST to Midpoint between Intakes................................................................................................................................................ 11 clwA96_07.RSF: FHB Closest Point to 'A' CB intake (Emergency)............................................................................................................................... 12 clwA96_08.RSF: FHB Closest Point to 'B' CB intake (Emergency)............................................................................................................................... 13 clwA96_09.RSF: FHB Closest Point to Midpoint between Intakes............................................................................................................................. 14 clwA96_10.RSF: FHB Closest Point to CB intake (Normal).......................................................................................................................................... 15 clwA96_11.RSF: Closest ASD to 'A' CB intake (Emergency)........................................................................................................................................ 16 clwA96_12.RSF: Closest ASD to 'B' CB intake (Emergency)........................................................................................................................................ 17 clwA96_13.RSF: Closest ASD to Midpoint between Intakes....................................................................................................................................... 18 clwA96_14.RSF: Closest MSSV to 'A' CB intake (Emergency)..................................................................................................................................... 19 clwA96_15.RSF: Closest MSSV to 'B' CB intake (Emergency)...................................................................................................................................... 20 clwA96_16.RSF: Closest MSSV to Midpoint between Intakes.................................................................................................................................... 21 clwA96_17.RSF: Closest Main Steam Line Point to 'A' CB intake (Emergency).......................................................................................................... 22 clwA96_18.RSF: Closest Main Steam Line Point to 'B' CB intake (Emergency).......................................................................................................... 23 clwA96_19.RSF: Closest Main Steam Line Point to Midpoint between Intakes......................................................................................................... 24 clwA96_20.RSF: Closest Feedwater Line Point to 'A' CB intake (Emergency)............................................................................................................ 25 clwA96_21.RSF: Closest Feedwater Line Point to 'B' CB intake (Emergency)............................................................................................................. 26 clwA96_22.RSF: Closest Feedwater Line Point to Midpoint between Intakes........................................................................................................... 27 to ULNRC-06696 Page 3 of 94 clwA96_23.RSF: Containment Maintenance Hatch (DSM52) to 'A' CB intake (Emergency)...................................................................................... 28 clwA96_24.RSF: Containment Maintenance Hatch (DSM52) to 'B' CB intake (Emergency)...................................................................................... 29 clwA96_25.RSF: Containment Maintenance Hatch (DSM52) to Midpoint between Intakes..................................................................................... 30 clwA96_26.RSF: Steam Jet Air Ejector to 'A' CB intake (Emergency).......................................................................................................................... 31 clwA96_27.RSF: Steam Jet Air Ejector to 'B' CB intake (Emergency).......................................................................................................................... 32 clwA96_28.RSF: Steam Jet Air Ejector to Midpoint between Intakes........................................................................................................................ 33 clwA96_29.RSF: Condenser to 'A' CB intake (Emergency).......................................................................................................................................... 34 clwA96_30.RSF: Condenser to 'B' CB intake (Emergency).......................................................................................................................................... 35 clwA96_31.RSF: Condenser to Midpoint between Intakes........................................................................................................................................ 36 clwA96_32.RSF: Stack/Plant Vent CB intake (Normal)............................................................................................................................................... 37 clwA96_33.RSF: Containment (Diffuse) to CB intake (Normal).................................................................................................................................. 38 clwA96_34.RSF: Containment (Diffuse) to CB Intake (Emergency) Midpoint............................................................................................................ 39 clwA96_35.RSF: Containment (Diffuse) 10 m to CB intake (Normal)......................................................................................................................... 40 clwA96_36.RSF: Containment (Diffuse) 20 m to CB intake (Normal)......................................................................................................................... 41 clwA96_37.RSF: Stack/Plant Vent to TSC Intake......................................................................................................................................................... 42 clwA96_39.RSF: RWST to CB intake (Normal)............................................................................................................................................................. 43 clwA96_40.RSF: RWST to TSC Intake.......................................................................................................................................................................... 44 clwA96_42.RSF: FHB Closest Point to TSC Intake....................................................................................................................................................... 45 clwA96_44.RSF: Closest ASD to CB intake (Normal)................................................................................................................................................... 46 clwA96_45.RSF: Closest ASD to TSC Intake................................................................................................................................................................. 47 clwA96_47.RSF: Closest MSSV to CB intake (Normal)................................................................................................................................................ 48 clwA96_48.RSF: Closest MSSV to TSC Intake.............................................................................................................................................................. 49 clwA96_50.RSF: Closest Main Steam Line Point to CB intake (Normal)..................................................................................................................... 50 to ULNRC-06696 Page 4 of 94 clwA96_51.RSF: Closest Main Steam Line Point to TSC Intake................................................................................................................................... 51 clwA96_53.RSF: Closest Feedwater Line Point to CB intake (Normal)....................................................................................................................... 52 clwA96_54.RSF: Closest Feedwater Line Point to TSC Intake..................................................................................................................................... 53 clwA96_56.RSF: Containment Maintenance Hatch (DSM52) to CB intake (Normal)................................................................................................. 54 clwA96_57.RSF: Containment Maintenance Hatch (DSM52) to TSC Intake............................................................................................................... 55 clwA96_59.RSF: Steam Jet Air Ejector to CB intake (Normal).................................................................................................................................... 56 clwA96_60.RSF: Steam Jet Air Ejector to TSC Intake.................................................................................................................................................. 57 clwA96_62.RSF: Condenser to CB intake (Normal)..................................................................................................................................................... 58 clwA96_63.RSF: Condenser to TSC Intake.................................................................................................................................................................. 59 clwA96_65.RSF: TDAFP Exhaust Vent to 'A' CB intake (Emergency).......................................................................................................................... 60 clwA96_66.RSF: TDAFP Exhaust Vent to 'B' CB intake (Emergency)........................................................................................................................... 61 clwA96_67.RSF: TDAFP Exhaust Vent to Midpoint between Intakes......................................................................................................................... 62 clwA96_68.RSF: TDAFP Exhaust Vent to CB intake (Normal)..................................................................................................................................... 63 clwA96_69.RSF: TDAFP Exhaust Vent to TSC Intake................................................................................................................................................... 64 clwA96_71.RSF: Containment (Diffuse) to TSC Intake................................................................................................................................................ 65 clwA96_73.RSF: Emergency Personnel Access Hatch to 'A' CB intake (Emergency).................................................................................................. 66 clwA96_74.RSF: Emergency Personnel Access Hatch to 'B' CB intake (Emergency).................................................................................................. 67 clwA96_75.RSF: Emergency Personnel Access Hatch to Midpoint between Intakes................................................................................................. 68 clwA96_76.RSF: Emergency Personnel Access Hatch to CB intake (Normal)............................................................................................................. 69 clwA96_77.RSF: Emergency Personnel Access Hatch to TSC Intake........................................................................................................................... 70 rwst_mp1.RSF: RWST to Access Point 1...................................................................................................................................................................... 71 rwst_mp2.RSF: RWST to Access Point 2...................................................................................................................................................................... 72 rwst_mp3.RSF: RWST to Access Point 3...................................................................................................................................................................... 73 to ULNRC-06696 Page 5 of 94 rwst_mp4.RSF: RWST to Access Point 4...................................................................................................................................................................... 74 rwst_mp4p5.RSF: RWST to Closest Point of Segment from Access Point 4 to Access Point 5................................................................................... 75 rwst_mp5.RSF: RWST to Access Point 5...................................................................................................................................................................... 76 rwst_mp6.RSF: RWST to Access Point 6...................................................................................................................................................................... 77 rwst_mp7.RSF: RWST to Access Point 7...................................................................................................................................................................... 78 vent_mp1.RSF: Stack/Plant Vent to Access Point 1.................................................................................................................................................... 79 vent_mp1_0height.RSF: Stack/Plant Vent to Access Point 1 (Zero Receptor Height)................................................................................................ 80 vent_mp2.RSF: Stack/Plant Vent to Access Point 2.................................................................................................................................................... 81 vent_mp2_0height.RSF: Stack/Plant Vent to Access Point 2 (Zero Receptor Height)................................................................................................ 82 vent_mp3.RSF: Stack/Plant Vent to Access Point 3.................................................................................................................................................... 83 vent_mp3_0height.RSF: Stack/Plant Vent to Access Point 3 (Zero Receptor Height)................................................................................................ 84 vent_mp4.RSF: Stack/Plant Vent to Access Point 4.................................................................................................................................................... 85 vent_mp4_0height.RSF: Stack/Plant Vent to Access Point 4 (Zero Receptor Height)................................................................................................ 86 vent_mp4p5.RSF: Stack/Plant Vent to Closest Point of Segment from Access Point 4 to Access Point 5................................................................. 87 vent_mp4p5_0height.RSF: Stack/Plant Vent to Closest Point of Segment from Access Point 4 to Access Point 5 (Zero Receptor Height)............. 88 vent_mp5.RSF: Stack/Plant Vent to Access Point 5.................................................................................................................................................... 89 vent_mp5_0height.RSF: Stack/Plant Vent to Access Point 5 (Zero Receptor Height)................................................................................................ 90 vent_mp6.RSF: Stack/Plant Vent to Access Point 6.................................................................................................................................................... 91 vent_mp6_0height.RSF: Stack/Plant Vent to Access Point 6 (Zero Receptor Height)................................................................................................ 92 vent_mp7.RSF: Stack/Plant Vent to Access Point 7.................................................................................................................................................... 93 vent_mp7_0height.RSF: Stack/Plant Vent to Access Point 7 (Zero Receptor Height)................................................................................................ 94 to ULNRC-06696 Page 6 of 94 clwA96_01.RSF: Stack/Plant Vent to 'A' CB intake (Emergency) 4 NAI-1900-06_R0, clwA96_01 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 66.3 1526.
0.00
.00
.00 339 90 71.3 5.50 0.00 clwA96_01.log clwA96_01.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 7 of 94 clwA96_02.RSF: Stack/Plant Vent to 'B' CB intake (Emergency) 4 NAI-1900-06_R0, clwA96_02 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 66.3 1526.
0.00
.00
.00 338 90 70.9 5.50 0.00 clwA96_02.log clwA96_02.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 8 of 94 clwA96_03.RSF: Stack/Plant Vent to Midpoint between Intakes 4 NAI-1900-06_R0, clwA96_03 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 66.3 1526.
0.00
.00
.00 338 90 71.1 5.50 0.00 clwA96_03.log clwA96_03.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 9 of 94 clwA96_04.RSF: RWST to 'A' CB intake (Emergency) 4 NAI-1900-06_R0, clwA96_04 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 16.5 0.01 0.00
.00
.00 20 90 94.9 5.50 0.00 clwA96_04.log clwA96_04.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 10 of 94 clwA96_05.RSF: RWST to 'B' CB intake (Emergency) 4 NAI-1900-06_R0, clwA96_05 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 16.5 0.01 0.00
.00
.00 19 90 93.8 5.50 0.00 clwA96_05.log clwA96_05.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 11 of 94 clwA96_06.RSF: RWST to Midpoint between Intakes 4 NAI-1900-06_R0, clwA96_06 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 16.5 0.01 0.00
.00
.00 20 90 94.3 5.50 0.00 clwA96_06.log clwA96_06.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 12 of 94 clwA96_07.RSF: FHB Closest Point to 'A' CB intake (Emergency) 4 NAI-1900-06_R0, clwA96_07 CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 60.0 2
1 5.5 0.01 0.00
.00
.00 3 90 74.4 5.50 0.00 clwA96_07.log clwA96_07.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 13 of 94 clwA96_08.RSF: FHB Closest Point to 'B' CB intake (Emergency) 4 NAI-1900-06_R0, clwA96_08 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 5.5 0.01 0.00
.00
.00 2 90 73.6 5.50 0.00 clwA96_08.log clwA96_08.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 14 of 94 clwA96_09.RSF: FHB Closest Point to Midpoint between Intakes 4 NAI-1900-06_R0, clwA96_09 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 5.5 0.01 0.00
.00
.00 3 90 74.0 5.50 0.00 clwA96_09.log clwA96_09.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 15 of 94 clwA96_10.RSF: FHB Closest Point to CB intake (Normal) 4 NAI-1900-06_R0, clwA96_10 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 22.5 0.01 0.00
.00
.00 41 90 52.2 22.5 0.00 clwA96_10.log clwA96_10.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 16 of 94 clwA96_11.RSF: Closest ASD to 'A' CB intake (Emergency) 4 NAI-1900-06_R0, clwA96_11 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 35.5 0.01 0.00
.00
.00 312 90 60.7 5.50 0.00 clwA96_11.log clwA96_11.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 17 of 94 clwA96_12.RSF: Closest ASD to 'B' CB intake (Emergency) 4 NAI-1900-06_R0, clwA96_12 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 35.5 0.01 0.00
.00
.00 311 90 60.8 5.50 0.00 clwA96_12.log clwA96_12.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 18 of 94 clwA96_13.RSF: Closest ASD to Midpoint between Intakes 4 NAI-1900-06_R0, clwA96_13 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 35.5 0.01 0.00
.00
.00 312 90 60.7 5.50 0.00 clwA96_13.log clwA96_13.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 19 of 94 clwA96_14.RSF: Closest MSSV to 'A' CB intake (Emergency) 4 NAI-1900-06_R0, clwA96_14 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 34.8 0.01 0.00
.00
.00 317 90 60.5 5.50 0.00 clwA96_14.log clwA96_14.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 20 of 94 clwA96_15.RSF: Closest MSSV to 'B' CB intake (Emergency) 4 NAI-1900-06_R0, clwA96_15 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 34.8 0.01 0.00
.00
.00 316 90 60.5 5.50 0.00 clwA96_15.log clwA96_15.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 21 of 94 clwA96_16.RSF: Closest MSSV to Midpoint between Intakes 4 NAI-1900-06_R0, clwA96_16 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 34.8 0.01 0.00
.00
.00 317 90 60.5 5.50 0.00 clwA96_16.log clwA96_16.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 22 of 94 clwA96_17.RSF: Closest Main Steam Line Point to 'A' CB intake (Emergency) 4 NAI-1900-06_R0, clwA96_17 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 12.0 0.01 0.00
.00
.00 316 90 60.5 5.50 0.00 clwA96_17.log clwA96_17.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 23 of 94 clwA96_18.RSF: Closest Main Steam Line Point to 'B' CB intake (Emergency) 4 NAI-1900-06_R0, clwA96_18 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 12.0 0.01 0.00
.00
.00 316 90 60.5 5.50 0.00 clwA96_18.log clwA96_18.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 24 of 94 clwA96_19.RSF: Closest Main Steam Line Point to Midpoint between Intakes 4 NAI-1900-06_R0, clwA96_19 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 12.0 0.01 0.00
.00
.00 316 90 60.5 5.50 0.00 clwA96_19.log clwA96_19.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 25 of 94 clwA96_20.RSF: Closest Feedwater Line Point to 'A' CB intake (Emergency) 4 NAI-1900-06_R0, clwA96_20 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 8.7 0.01 0.00
.00
.00 316 90 60.5 5.50 0.00 clwA96_20.log clwA96_20.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 26 of 94 clwA96_21.RSF: Closest Feedwater Line Point to 'B' CB intake (Emergency) 4 NAI-1900-06_R0, clwA96_21 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 8.7 0.01 0.00
.00
.00 316 90 60.5 5.50 0.00 clwA96_21.log clwA96_21.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 27 of 94 clwA96_22.RSF: Closest Feedwater Line Point to Midpoint between Intakes 4 NAI-1900-06_R0, clwA96_22 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 8.7 0.01 0.00
.00
.00 316 90 60.5 5.50 0.00 clwA96_22.log clwA96_22.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 28 of 94 clwA96_23.RSF: Containment Maintenance Hatch (DSM52) to 'A' CB intake (Emergency) 4 NAI-1900-06_R0, clwA96_23 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 17.4 0.01 0.00
.00
.00 342 90 93.2 5.50 0.00 clwA96_23.log clwA96_23.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 29 of 94 clwA96_24.RSF: Containment Maintenance Hatch (DSM52) to 'B' CB intake (Emergency) 4 NAI-1900-06_R0, clwA96_24 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 17.4 0.01 0.00
.00
.00 342 90 92.7 5.50 0.00 clwA96_24.log clwA96_24.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 30 of 94 clwA96_25.RSF: Containment Maintenance Hatch (DSM52) to Midpoint between Intakes 4 NAI-1900-06_R0, clwA96_25 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 17.4 0.01 0.00
.00
.00 342 90 93.0 5.50 0.00 clwA96_25.log clwA96_25.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 31 of 94 clwA96_26.RSF: Steam Jet Air Ejector to 'A' CB intake (Emergency) 4 NAI-1900-06_R0, clwA96_26 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 1.4 0.01 0.00
.00
.00 293 90 62.2 5.50 0.00 clwA96_26.log clwA96_26.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 32 of 94 clwA96_27.RSF: Steam Jet Air Ejector to 'B' CB intake (Emergency) 4 NAI-1900-06_R0, clwA96_27 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 1.4 0.01 0.00
.00
.00 292 90 62.6 5.50 0.00 clwA96_27.log clwA96_27.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 33 of 94 clwA96_28.RSF: Steam Jet Air Ejector to Midpoint between Intakes 4 NAI-1900-06_R0, clwA96_28 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 1.4 0.01 0.00
.00
.00 293 90 62.4 5.50 0.00 clwA96_28.log clwA96_28.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 34 of 94 clwA96_29.RSF: Condenser to 'A' CB intake (Emergency) 4 NAI-1900-06_R0, clwA96_29 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 5.5 0.01 0.00
.00
.00 281 90 73.3 5.50 0.00 clwA96_29.log clwA96_29.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 35 of 94 clwA96_30.RSF: Condenser to 'B' CB intake (Emergency) 4 NAI-1900-06_R0, clwA96_30 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 5.5 0.01 0.00
.00
.00 280 90 74.1 5.50 0.00 clwA96_30.log clwA96_30.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 36 of 94 clwA96_31.RSF: Condenser to Midpoint between Intakes 4 NAI-1900-06_R0, clwA96_31 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 5.5 0.01 0.00
.00
.00 281 90 73.7 5.50 0.00 clwA96_31.log clwA96_31.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 37 of 94 clwA96_32.RSF: Stack/Plant Vent CB intake (Normal) 4 NAI-1900-06_R0, clwA96_32 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 66.3 1526.
0.00
.00
.00 8 90 31.9 22.5 0.00 clwA96_32.log clwA96_32.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 0.00 0.00 n
to ULNRC-06696 Page 38 of 94 clwA96_33.RSF: Containment (Diffuse) to CB intake (Normal) 4 NAI-1900-06_R0, clwA96_33 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 34.8 1526.
0.00
.00
.00 8 90 9.3 22.5 0.00 clwA96_33.log clwA96_33.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 7.52 6.59 n
to ULNRC-06696 Page 39 of 94 clwA96_34.RSF: Containment (Diffuse) to CB Intake (Emergency) Midpoint 4 NAI-1900-06_R0, clwA96_34 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 34.8 1526.
0.00
.00
.00 339 90 47.6 5.5 0.00 clwA96_34.log clwA96_34.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 7.52 6.59 n
to ULNRC-06696 Page 40 of 94 clwA96_35.RSF: Containment (Diffuse) 10 m to CB intake (Normal) 4 NAI-1900-06_R0, clwA96_35 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 34.8 1526.
0.00
.00
.00 8 90
- 10.
22.5 0.00 clwA96_35.log clwA96_35.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 7.52 6.59 n
to ULNRC-06696 Page 41 of 94 clwA96_36.RSF: Containment (Diffuse) 20 m to CB intake (Normal) 4 NAI-1900-06_R0, clwA96_36 CALL_ARCON_2013_Rev1.met CALL_ARCON_2014_Rev1.met CALL_ARCON_2015_Rev1.met CALL_ARCON_2016_Rev1.met 10.0 60.0 2
1 34.8 1526.
0.00
.00
.00 8 90
- 20.
22.5 0.00 clwA96_36.log clwA96_36.CFD 0.20 0.50 4.30 1 2 4 8 12 24 96 168 360 720 1 2 4 8 11 22 87 152 324 720 7.52 6.59 n
to ULNRC-06696 Page 42 of 94 clwA96_37.RSF: Stack/Plant Vent to TSC Intake 4 NAI-1900-06_R1, clwA96_37 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 66.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 49 90 ! *** Angle, sector width (degrees) 223.0 ! *** Horizontal distance to source (m) 2.4 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_37.log clwA96_37.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 43 of 94 clwA96_39.RSF: RWST to CB intake (Normal) 4 NAI-1900-06_R1, clwA96_39 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 16.5 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 49 90 ! *** Angle, sector width (degrees) 82.7 ! *** Horizontal distance to source (m) 22.5 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_39.log clwA96_39.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 44 of 94 clwA96_40.RSF: RWST to TSC Intake 4 NAI-1900-06_R1, clwA96_40 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 16.5 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 53 90 ! *** Angle, sector width (degrees) 282.6 ! *** Horizontal distance to source (m) 2.4 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_40.log clwA96_40.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 45 of 94 clwA96_42.RSF: FHB Closest Point to TSC Intake 4 NAI-1900-06_R1, clwA96_42 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 2.4 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 46 90 ! *** Angle, sector width (degrees) 250.2 ! *** Horizontal distance to source (m) 2.4 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_42.log clwA96_42.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 46 of 94 clwA96_44.RSF: Closest ASD to CB intake (Normal) 4 NAI-1900-06_R1, clwA96_44 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 35.5 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 292 90 ! *** Angle, sector width (degrees) 15.9 ! *** Horizontal distance to source (m) 22.5 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_44.log clwA96_44.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 47 of 94 clwA96_45.RSF: Closest ASD to TSC Intake
.4 NAI-1900-06_R1, clwA96_45 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 35.5 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 48 90 ! *** Angle, sector width (degrees) 191.3 ! *** Horizontal distance to source (m) 2.4 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_45.log clwA96_45.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 48 of 94 clwA96_47.RSF: Closest MSSV to CB intake (Normal) 4 NAI-1900-06_R1, clwA96_47 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 34.8 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 316 90 ! *** Angle, sector width (degrees) 14.5 ! *** Horizontal distance to source (m) 22.5 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_47.log clwA96_47.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 49 of 94 clwA96_48.RSF: Closest MSSV to TSC Intake 4 NAI-1900-06_R1, clwA96_48 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 34.8 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 48 90 ! *** Angle, sector width (degrees) 195.2 ! *** Horizontal distance to source (m) 2.4 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_48.log clwA96_48.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 50 of 94 clwA96_50.RSF: Closest Main Steam Line Point to CB intake (Normal) 4 NAI-1900-06_R1, clwA96_50 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 12.0 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 316 90 ! *** Angle, sector width (degrees) 14.5 ! *** Horizontal distance to source (m) 22.5 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_50.log clwA96_50.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 51 of 94 clwA96_51.RSF: Closest Main Steam Line Point to TSC Intake 4 NAI-1900-06_R1, clwA96_51 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 12.0 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 46 90 ! *** Angle, sector width (degrees) 90.5 ! *** Horizontal distance to source (m) 2.4 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_51.log clwA96_51.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 52 of 94 clwA96_53.RSF: Closest Feedwater Line Point to CB intake (Normal) 4 NAI-1900-06_R1, clwA96_53 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 8.7 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 316 90 ! *** Angle, sector width (degrees) 14.5 ! *** Horizontal distance to source (m) 22.5 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_53.log clwA96_53.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 53 of 94 clwA96_54.RSF: Closest Feedwater Line Point to TSC Intake 4 NAI-1900-06_R1, clwA96_54 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 8.7 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 46 90 ! *** Angle, sector width (degrees) 90.5 ! *** Horizontal distance to source (m) 2.4 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_54.log clwA96_54.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 54 of 94 clwA96_56.RSF: Containment Maintenance Hatch (DSM52) to CB intake (Normal) 4 NAI-1900-06_R1, clwA96_56 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 17.4 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 2 90 ! *** Angle, sector width (degrees) 54.1 ! *** Horizontal distance to source (m) 22.5 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_56.log clwA96_56.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 55 of 94 clwA96_57.RSF: Containment Maintenance Hatch (DSM52) to TSC Intake 4 NAI-1900-06_R1, clwA96_57 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 17.4 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 46 90 ! *** Angle, sector width (degrees) 236.6 ! *** Horizontal distance to source (m) 2.4 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_57.log clwA96_57.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 56 of 94 clwA96_59.RSF: Steam Jet Air Ejector to CB intake (Normal) 4 NAI-1900-06_R1, clwA96_59 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 1.4 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 249 90 ! *** Angle, sector width (degrees) 28.9 ! *** Horizontal distance to source (m) 22.5 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_59.log clwA96_59.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 57 of 94 clwA96_60.RSF: Steam Jet Air Ejector to TSC Intake 4 NAI-1900-06_R1, clwA96_60 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 1.4 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 50 90 ! *** Angle, sector width (degrees) 171.6 ! *** Horizontal distance to source (m) 2.4 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_60.log clwA96_60.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 58 of 94 clwA96_62.RSF: Condenser to CB intake (Normal) 4 NAI-1900-06_R1, clwA96_62 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 7.1 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 244 90 ! *** Angle, sector width (degrees) 46.7 ! *** Horizontal distance to source (m) 22.5 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_62.log clwA96_62.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 59 of 94 clwA96_63.RSF: Condenser to TSC Intake 4 NAI-1900-06_R1, clwA96_63 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 2.4 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 48 90 ! *** Angle, sector width (degrees) 123.3 ! *** Horizontal distance to source (m) 2.4 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_63.log clwA96_63.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 60 of 94 clwA96_65.RSF: TDAFP Exhaust Vent to 'A' CB intake (Emergency) 4 NAI-1900-06_R1, clwA96_65 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 13.9 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 315 90 ! *** Angle, sector width (degrees) 75.6 ! *** Horizontal distance to source (m) 5.5 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_65.log clwA96_65.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 61 of 94 clwA96_66.RSF: TDAFP Exhaust Vent to 'B' CB intake (Emergency) 4 NAI-1900-06_R1, clwA96_66 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 13.9 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 314 90 ! *** Angle, sector width (degrees) 75.6 ! *** Horizontal distance to source (m) 5.5 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_66.log clwA96_66.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 62 of 94 clwA96_67.RSF: TDAFP Exhaust Vent to Midpoint between Intakes 4 NAI-1900-06_R1, clwA96_67 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 13.9 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 314 90 ! *** Angle, sector width (degrees) 75.6 ! *** Horizontal distance to source (m) 5.5 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_67.log clwA96_67.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 63 of 94 clwA96_68.RSF: TDAFP Exhaust Vent to CB intake (Normal) 4 NAI-1900-06_R1, clwA96_68 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 13.9 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 308 90 ! *** Angle, sector width (degrees) 29.8 ! *** Horizontal distance to source (m) 22.5 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_68.log clwA96_68.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 64 of 94 clwA96_69.RSF: TDAFP Exhaust Vent to TSC Intake 4 NAI-1900-06_R1, clwA96_69 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 13.9 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 47 90 ! *** Angle, sector width (degrees) 193.7 ! *** Horizontal distance to source (m) 2.4 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_69.log clwA96_69.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 65 of 94 clwA96_71.RSF: Containment (Diffuse) to TSC Intake 4 NAI-1900-06_R1, clwA96_71 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 22.6 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 49 90 ! *** Angle, sector width (degrees) 200.4 ! *** Horizontal distance to source (m) 2.4 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_71.log clwA96_71.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 66 of 94 clwA96_73.RSF: Emergency Personnel Access Hatch to 'A' CB intake (Emergency) 4 NAI-1900-06_R2, clwA96_73 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 4.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 328 90 ! *** Angle, sector width (degrees) 88.7 ! *** Horizontal distance to source (m) 5.5 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_73.log clwA96_73.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 67 of 94 clwA96_74.RSF: Emergency Personnel Access Hatch to 'B' CB intake (Emergency) 4 NAI-1900-06_R2, clwA96_74 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 4.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 328 90 ! *** Angle, sector width (degrees) 88.4 ! *** Horizontal distance to source (m) 5.5 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_74.log clwA96_74.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 68 of 94 clwA96_75.RSF: Emergency Personnel Access Hatch to Midpoint between Intakes 4 NAI-1900-06_R2, clwA96_75 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 4.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 328 90 ! *** Angle, sector width (degrees) 88.5 ! *** Horizontal distance to source (m) 5.5 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_75.log clwA96_75.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 69 of 94 clwA96_76.RSF: Emergency Personnel Access Hatch to CB intake (Normal) 4 NAI-1900-06_R2, clwA96_76 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 4.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 338 90 ! *** Angle, sector width (degrees) 43.8 ! *** Horizontal distance to source (m) 22.5 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_76.log clwA96_76.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 70 of 94 clwA96_77.RSF: Emergency Personnel Access Hatch to TSC Intake 4 NAI-1900-06_R2, clwA96_77 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 4.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 44 90 ! *** Angle, sector width (degrees) 214.1 ! *** Horizontal distance to source (m) 2.4 ! *** Intake height (m) 0.00 ! Grade difference (0.0) clwA96_77.log clwA96_77.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 71 of 94 rwst_mp1.RSF: RWST to Access Point 1 4 LOCA Mission Dose, Point 1 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 16.5 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 70 90 ! *** Angle, sector width (degrees) 603.3 ! *** Horizontal distance to source (m) 2.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) rwst_mp1.log rwst_mp1.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 72 of 94 rwst_mp2.RSF: RWST to Access Point 2 4 LOCA Mission Dose, Point 2 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 16.5 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 83 90 ! *** Angle, sector width (degrees) 405.7 ! *** Horizontal distance to source (m) 2.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) rwst_mp2.log rwst_mp2.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 73 of 94 rwst_mp3.RSF: RWST to Access Point 3 4 LOCA Mission Dose, Point 3 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 16.5 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 67 90 ! *** Angle, sector width (degrees) 347.8 ! *** Horizontal distance to source (m) 2.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) rwst_mp3.log rwst_mp3.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 74 of 94 rwst_mp4.RSF: RWST to Access Point 4 4 LOCA Mission Dose, Point 4 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 16.5 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 74 90 ! *** Angle, sector width (degrees) 271.6 ! *** Horizontal distance to source (m) 2.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) rwst_mp4.log rwst_mp4.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 75 of 94 rwst_mp4p5.RSF: RWST to Closest Point of Segment from Access Point 4 to Access Point 5 4 LOCA Mission Dose, Point 4.5 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 16.5 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 46 90 ! *** Angle, sector width (degrees) 228.8 ! *** Horizontal distance to source (m) 2.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) rwst_mp4p5.log rwst_mp4p5.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 76 of 94 rwst_mp5.RSF: RWST to Access Point 5 4 LOCA Mission Dose, Point 5 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 16.5 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 30 90 ! *** Angle, sector width (degrees) 238.4 ! *** Horizontal distance to source (m) 2.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) rwst_mp5.log rwst_mp5.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 77 of 94 rwst_mp6.RSF: RWST to Access Point 6 4 LOCA Mission Dose, Point 6 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 16.5 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 19 90 ! *** Angle, sector width (degrees) 148.0 ! *** Horizontal distance to source (m) 2.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) rwst_mp6.log rwst_mp6.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 78 of 94 rwst_mp7.RSF: RWST to Access Point 7 4 LOCA Mission Dose, Point 7 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 16.5 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 30 90 ! *** Angle, sector width (degrees) 137.8 ! *** Horizontal distance to source (m) 2.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) rwst_mp7.log rwst_mp7.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 79 of 94 vent_mp1.RSF: Stack/Plant Vent to Access Point 1 4 LOCA Mission Dose, Point 1 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 66.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 70 90 ! *** Angle, sector width (degrees) 538.4 ! *** Horizontal distance to source (m) 2.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) vent_mp1.log vent_mp1.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 80 of 94 vent_mp1_0height.RSF: Stack/Plant Vent to Access Point 1 (Zero Receptor Height) 4 LOCA Mission Dose, Point 1 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 66.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 70 90 ! *** Angle, sector width (degrees) 538.4 ! *** Horizontal distance to source (m) 0.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) vent_mp1_0height.log vent_mp1_0height.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 81 of 94 vent_mp2.RSF: Stack/Plant Vent to Access Point 2 4 LOCA Mission Dose, Point 2 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 66.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 86 90 ! *** Angle, sector width (degrees) 347.7 ! *** Horizontal distance to source (m) 2.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) vent_mp2.log vent_mp2.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 82 of 94 vent_mp2_0height.RSF: Stack/Plant Vent to Access Point 2 (Zero Receptor Height) 4 LOCA Mission Dose, Point 2 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 66.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 86 90 ! *** Angle, sector width (degrees) 347.7 ! *** Horizontal distance to source (m) 0.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) vent_mp2_0height.log vent_mp2_0height.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 83 of 94 vent_mp3.RSF: Stack/Plant Vent to Access Point 3 4 LOCA Mission Dose, Point 3 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 66.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 67 90 ! *** Angle, sector width (degrees) 286.2 ! *** Horizontal distance to source (m) 2.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) vent_mp3.log vent_mp3.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 84 of 94 vent_mp3_0height.RSF: Stack/Plant Vent to Access Point 3 (Zero Receptor Height) 4 LOCA Mission Dose, Point 3 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 66.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 67 90 ! *** Angle, sector width (degrees) 286.2 ! *** Horizontal distance to source (m) 0.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) vent_mp3_0height.log vent_mp3_0height.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 85 of 94 vent_mp4.RSF: Stack/Plant Vent to Access Point 4 4 LOCA Mission Dose, Point 4 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 66.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 75 90 ! *** Angle, sector width (degrees) 212.1 ! *** Horizontal distance to source (m) 2.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) vent_mp4.log vent_mp4.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 86 of 94 vent_mp4_0height.RSF: Stack/Plant Vent to Access Point 4 (Zero Receptor Height) 4 LOCA Mission Dose, Point 4 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 66.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 75 90 ! *** Angle, sector width (degrees) 212.1 ! *** Horizontal distance to source (m) 0.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) vent_mp4_0height.log vent_mp4_0height.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 87 of 94 vent_mp4p5.RSF: Stack/Plant Vent to Closest Point of Segment from Access Point 4 to Access Point 5 4 LOCA Mission Dose, Point 4.5 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 66.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 46 90 ! *** Angle, sector width (degrees) 174.6 ! *** Horizontal distance to source (m) 2.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) vent_mp4p5.log vent_mp4p5.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 88 of 94 vent_mp4p5_0height.RSF: Stack/Plant Vent to Closest Point of Segment from Access Point 4 to Access Point 5 (Zero Receptor Height) 4 LOCA Mission Dose, Point 4.5 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 66.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 46 90 ! *** Angle, sector width (degrees) 174.6 ! *** Horizontal distance to source (m) 0.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) vent_mp4p5_0height.log vent_mp4p5_0height.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 89 of 94 vent_mp5.RSF: Stack/Plant Vent to Access Point 5 4 LOCA Mission Dose, Point 5 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 66.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 19 90 ! *** Angle, sector width (degrees) 197.4 ! *** Horizontal distance to source (m) 2.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) vent_mp5.log vent_mp5.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 90 of 94 vent_mp5_0height.RSF: Stack/Plant Vent to Access Point 5 (Zero Receptor Height) 4 LOCA Mission Dose, Point 5 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 66.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 19 90 ! *** Angle, sector width (degrees) 197.4 ! *** Horizontal distance to source (m) 0.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) vent_mp5_0height.log vent_mp5_0height.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 91 of 94 vent_mp6.RSF: Stack/Plant Vent to Access Point 6 4 LOCA Mission Dose, Point 6 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 66.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 357 90 ! *** Angle, sector width (degrees) 119.5 ! *** Horizontal distance to source (m) 2.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) vent_mp6.log vent_mp6.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 92 of 94 vent_mp6_0height.RSF: Stack/Plant Vent to Access Point 6 (Zero Receptor Height) 4 LOCA Mission Dose, Point 6 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 66.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 357 90 ! *** Angle, sector width (degrees) 119.5 ! *** Horizontal distance to source (m) 0.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) vent_mp6_0height.log vent_mp6_0height.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 93 of 94 vent_mp7.RSF: Stack/Plant Vent to Access Point 7 4 LOCA Mission Dose, Point 7 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 66.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 8 90 ! *** Angle, sector width (degrees) 98.2 ! *** Horizontal distance to source (m) 2.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) vent_mp7.log vent_mp7.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output to ULNRC-06696 Page 94 of 94 vent_mp7_0height.RSF: Stack/Plant Vent to Access Point 7 (Zero Receptor Height) 4 LOCA Mission Dose, Point 7 ! Number of met files; *** title ! Values marked by *** change for different cases. Note that string inputs cannot have a comment, so not all inputs are annotated.
CALL_ARCON_2013_Rev1.MET CALL_ARCON_2014_Rev1.MET CALL_ARCON_2015_Rev1.MET CALL_ARCON_2016_Rev1.MET 10.0 ! Lower height (10 m) 60.0 ! Upper height (60 m) 2 ! Wind units (2=mph, 1=m/s) 1 ! Release type (1=ground) 66.3 ! *** Release height, m 0.01 ! Building area, m^2 0.00 ! Vertical velocity (0 for ground source)
.00 ! Stack flow (0 for ground source)
.00 ! Stack radius (0 for ground source) 8 90 ! *** Angle, sector width (degrees) 98.2 ! *** Horizontal distance to source (m) 0.0 ! *** Intake height (m) 0.00 ! Grade difference (0.0) vent_mp7_0height.log vent_mp7_0height.CFD 0.20 ! Surface roughness (0.2) 0.50 ! Calm speed 4.30 ! Averaging sector width constant (4.3) 1 2 4 8 12 24 96 168 360 720 ! Hours in averages 1 2 4 8 11 22 87 152 324 720 ! Min number of hours 0.00 0.00 ! Initial sigma_y and sigma_z (0 if not diffuse source) n ! Flag for expanded output