TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT Extended Power Uprate Steam Dryers March 20, 2008

Steam Dryer Analyses AH -ft Unit 1 Analysis Submitted March 6, 2008 Includes:

o Unit 1 specific strain gage data o Latest bias and uncertainty o FEM corrections o Noise reduction Results Location Node SR-P SR-a Freq. Shift (%)

.1 opCoerInerHo"~r co Oerta17 pro,Perf.P,ate

~

fý88059-.

30

2. Top Cover/Tie Bar Base 107054 3.47 1.59 10
3. Top Cover/Tie Bar Base 102407 3.29 1.62 2.5
4. Top Cover Middle Hood/Top Perf. Plate/Top Cover Overlap 91420 3.05 1.63 10
5. Top Cover/Tie Bar Base 96561 3.96 1.94 10
6. Top Perf/Top Cover/Dam Plate 103088 4.31 1.98 7.5
7. Submerged Drain Channel/Skirt 104539 2.57 2.15 10
8. Dam Plate/Lock 102521 4.76 2.19 7.5
9. Top Cover Inner Hood/Hood Support/Tie Bar Base 103094 4

2.28 10

10. Top Perf/Top Cover/Dam Plate 103089 5.14 2.4 5

2

Steam Dryer Analyses Unit 2 Analysis Scheduled to be submitted March 31, 2008 Will include:

o Latest bias and uncertainty o FEM corrections

" Noise reduction 3

Steam Dryer Analyses Unit 3 Analysis Scheduled to be submitted June 2008 Will include:

o Unit 3 specific strain gage data o

Latest bias and uncertainty o

FEM corrections o

Noise reduction Outage status o Outage began March 18 o

Acoustic vibration suppressors will be installed 0Strain gage data will be obtained following restart 4

Steam Dryer Analyses Potential for SRV Resonance Frequency range 105 Hz to 112 Hz most likely No demonstrated SRV resonance at CLTP velocities from plant data 1/5 Scale testing of A & B main steam lines o Testing shows SRV frequency onset starting at CLTP and small increase at EPU Mach numbers 1/8 Scale testing for EPU prediction o In progress

" Used to determine need for mitigation modifications 5

RAI Status

  • Group 1 -January 31,2008 Generic questions, plans to use unit-specific data, clarifications
  • Group 2 - March 6, 2008 Unit 1 stress analysis, damping
  • Group 3 -March 31, 2008

-Unit 2 stress analysis, misc.

  • Group 4 -June 15, 2008 Unit 3 stress analysis 6

Steam Dryer Monitoring Plan

" Draft provided for discussion

  • Includes Test plateaus at 5%

Power increments of 2.5%

Performance criteria based on limit curves Proposed license conditions 7