MONTHYEARIR 05000327/20250102024-10-29029 October 2024 Notification of Sequoyah, Units 1 and 2 - Comprehensive Engineering Team Inspection - U.S. Nuclear Regulatory Commission Inspection Report 05000327/2025010 and 05000328/2025010 IR 05000327/20240052024-08-26026 August 2024 Updated Inspection Plan for Sequoyah Nuclear Plant, Units 1 and 2 - Report 05000327/2024005 and 05000328/2024005 IR 05000327/20240022024-07-31031 July 2024 Integrated Inspection Report 05000327/2024002 and 05000328/2024002 ML24145A0852024-05-30030 May 2024 1B-B Diesel Generator Failure - Final Significance Determination Letter IR 05000327/20240012024-04-17017 April 2024 Integrated Inspection Report 05000327/2024001 and 05000328/2024001 IR 05000327/20240902024-03-19019 March 2024 NRC Inspection Report 05000327-2024090 and 05000328-2024090 and Preliminary Greater than Green Finding and Apparent Violation IR 05000327/20244012024-03-12012 March 2024 – Security Baseline Inspection Report 05000327/2024401 and 05000328/2024401 IR 05000259/20230062024-02-28028 February 2024 Annual Assessment Letter for Sequoyah Nuclear Plant, Units 1, 2 - Report 05000259/2023006, 05000260/2023006 and 05000296/2023006 IR 05000327/20230042024-02-12012 February 2024 Integrated Inspection Report 05000327/2023004 and 05000328/2023004 and Apparent Violation IR 05000327/20234422024-01-11011 January 2024 95001 Supplemental Inspection Report 05000327/2023442 and 05000328/2023442 and Follow-Up Assessment Letter IR 05000327/20234202023-11-28028 November 2023 Security Baseline Inspection Report 05000327/2023420 and 05000328/2023420 IR 05000327/20230032023-11-0303 November 2023 – Integrated Inspection Report 05000327/2023003 and 05000328/2023003 IR 05000327/20230112023-10-16016 October 2023 Triennial Fire Protection Inspection Report 05000327/2023011 and 05000328/2023011 IR 05000327/20234032023-09-14014 September 2023 Cyber Security Inspection Report 05000327/2023403 and 05000328/2023403 (Cover Letter) IR 05000327/20230052023-08-29029 August 2023 Updated Inspection Plan for Sequoyah Nuclear Plant, Units 1 and 2 - Report 05000327/2023005 and 05000328/2023005 IR 05000327/20230022023-07-31031 July 2023 Integrated Inspection Report 05000327/2023002 and 05000328/2023002 IR 05000327/20230102023-07-20020 July 2023 – Biennial Problem Identification and Resolution Inspection Report 05000327/2023010 and 05000328/2023010 ML23163A0392023-06-13013 June 2023 – Notification of an NRC Fire Protection Team Inspection (FPTI) (NRC Inspection Report 05000327/2023011, 05000328/2023011) and Request for Information (RFI) IR 05000327/20233012023-05-15015 May 2023 – NRC Operator License Examination Report 05000327/2023301 and 05000328/2023301 IR 05000327/20230012023-05-0202 May 2023 Integrated Inspection Report 05000327/2023001 and 05000328/2023001 and Exercise of Enforcement Discretion IR 05000327/20234412023-04-20020 April 2023 Final Significance Determination for a Security-Related Greater than Green Finding, Nov & Assessment Followup Letter, 05000327/2023441 & 05000328/2023441 IR 05000327/20234022023-04-13013 April 2023 Security Baseline Inspection Report 05000327/2023402 and 05000328/2023402 IR 05000327/20220062023-03-0101 March 2023 Annual Assessment Letter for Sequoyah Nuclear Plant, Units 1 and 2 Report 05000327/2022006 and 05000328/2022006 IR 05000327/20234402023-02-13013 February 2023 – NRC Inspection Report 05000327/2023440 and 05000328/2023440; Preliminary Greater than Green and Apparent Violation Cover Letter IR 05000327/20220042023-02-10010 February 2023 Integrated Inspection Report 05000327/2022004 and 05000328/2022004 IR 05000327/20234012023-02-0606 February 2023 – Security Baseline Inspection Report 05000327/2023401 and 05000328/2023401 IR 05000327/20224402023-01-17017 January 2023 – Special Inspection Report 05000327/2022440 and 05000328/2022440 and Apparent Violation - Cover IR 05000327/20220032022-11-0707 November 2022 – Integrated Inspection Report 05000327/2022003 and 05000328/2022003 IR 05000327/20224012022-10-18018 October 2022 Material Control and Accounting Program Inspection Report 05000327/2022401 and 05000328/2022401 IR 05000327/20220052022-08-30030 August 2022 Updated Inspection Plan for Sequoyah Nuclear Plant, Units 1 and 2 - Report 05000327 2022005 and 05000328 2022005 - Final IR 05000327/20220022022-08-0101 August 2022 Integrated Inspection Report 05000327 2022002 and 05000328 2022002 IR 05000327/20220012022-05-11011 May 2022 Integrated Inspection Report 05000327/2022001, 05000328/2022001 and 07200034/2010002 IR 05000327/20223012022-05-10010 May 2022 NRC Operator Licensing Examination Approval 05000327/2022301 and 05000328/2022301 IR 05000327/20224022022-03-28028 March 2022 Security Baseline Inspection Report 05000327/2022402 and 05000328/2022402 IR 05000327/20210062022-03-0202 March 2022 Annual Assessment Letter for Sequoyah Nuclear Plant, Units 1 and 2 - (Report No. 05000327/2021006 and 05000328/2021006) IR 05000327/20210042022-02-0707 February 2022 Integrated Inspection Report 05000327/2021004 and 05000328/2021004 IR 05000327/20220102021-12-15015 December 2021 Notification of Sequoyah Nuclear Plant - Design Bases Assurance Inspection (Teams) - U.S. Nuclear Regulatory Commission Inspection Report 05000327/2022010 and 05000328/2022010 IR 05000327/20210032021-11-10010 November 2021 Integrated Inspection Report 05000327/2021003 and 05000328/2021003 and Apparent Violation and Exercise of Enforcement Discretion IR 05000327/20210052021-08-18018 August 2021 Updated Inspection Plan for Sequoyah Nuclear Plant, Units 1 and 2 Report 05000327/2021005 and 05000328/2021005 IR 05000327/20210022021-07-27027 July 2021 Integrated Inspection Report 05000327/2021002 and 05000328/2021002 IR 05000327/20210112021-07-19019 July 2021 Biennial Problem Identification and Resolution Inspection Report 05000327/2021011 and 05000328/2021011 IR 05000327/20210012021-04-27027 April 2021 Integrated Inspection Report 05000327/2021001 and 05000328/2021001 IR 05000327/20214012021-04-21021 April 2021 NRC Inspection Report 05000327/2021401 and 05000328/2021401 (U) IR 05000327/20210102021-04-21021 April 2021 NRC Inspection Report 05000327/2021010 and 05000328/2021010 IR 05000327/20200062021-03-0303 March 2021 Annual Assessment Letter for Sequoyah Nuclear Plant, Units 1 and 2 - Report 05000327/2020006 and 05000328/2020006 IR 05000327/20200042021-01-29029 January 2021 Integrated Inspection Report 05000327/2020004 and 05000328/2020004 IR 05000327/20204202020-11-20020 November 2020 Security Inspection Report 05000327/2020420 and 05000328/2020420 ML20321A2102020-11-20020 November 2020 Security Inspection Report 05000327/2020420 and 05000328/2020420 - Cover Letter IR 05000327/20200032020-11-10010 November 2020 Integrated Inspection Report 05000327/2020003, 05000328/2020003 and 07200034/2020002 IR 05000327/20200122020-10-20020 October 2020 Plants - Triennial Fire Protection Inspection Report 05000327/2020012 and 05000328/2020012 2024-08-26
[Table view] Category:Letter
MONTHYEARML24304A8492024-10-31031 October 2024 December 2024 Requalification Inspection Notification Letter IR 05000327/20250102024-10-29029 October 2024 Notification of Sequoyah, Units 1 and 2 - Comprehensive Engineering Team Inspection - U.S. Nuclear Regulatory Commission Inspection Report 05000327/2025010 and 05000328/2025010 ML24298A1172024-10-24024 October 2024 Cycle 26, 180-Day Steam Generator Tube Inspection Report CNL-24-074, Tennessee Valley Authority - Central Emergency Control Center Emergency Plan Implementing Procedure Revisions2024-10-23023 October 2024 Tennessee Valley Authority - Central Emergency Control Center Emergency Plan Implementing Procedure Revisions 05000327/LER-2024-001, Reactor Trip Due to a Turbine Trip2024-10-17017 October 2024 Reactor Trip Due to a Turbine Trip ML24282B0412024-10-15015 October 2024 Request for Withholding Information from Public Disclosure for Sequoyah Nuclear Plant, Units 1 and 2 and Watts Bar Nuclear Plant, Units 1 and 2 ML24260A1682024-10-0404 October 2024 Regulatory Audit Summary Related to Request to Add and Revise Notes Related to Technical Specification Table 3.3.2-1, Function 5 ML24284A1072024-09-26026 September 2024 Affidavit for Request for Withholding Information from Public Disclosure for Sequoyah Nuclear Plant, Units 1 and 2, and Watts Bar Nuclear Plant, Units 1 and 2 05000328/LER-2024-001, Reactor Trip Due to an Electrical Trouble Turbine Trip2024-09-25025 September 2024 Reactor Trip Due to an Electrical Trouble Turbine Trip CNL-24-060, Supplement to Request for Approval of the Tennessee Valley Authority Nuclear Quality Assurance Program Description2024-09-24024 September 2024 Supplement to Request for Approval of the Tennessee Valley Authority Nuclear Quality Assurance Program Description CNL-24-047, Decommitment of Flood Mode Mitigation Improvement Systems2024-09-24024 September 2024 Decommitment of Flood Mode Mitigation Improvement Systems ML24262A0602024-09-23023 September 2024 Summary of August 19, 2024, Meeting with Tennessee Valley Authority Regarding a Proposed Supplement to the Tennessee Valley Authority Nuclear Quality Assurance Plan ML24267A0402024-09-19019 September 2024 Cycle 27 Core Operating Limits Report Revision 0 CNL-24-065, Tennessee Valley Authority – Central Emergency Control Center Emergency Plan Implementing Procedure Revisions2024-09-18018 September 2024 Tennessee Valley Authority – Central Emergency Control Center Emergency Plan Implementing Procedure Revisions ML24185A1742024-09-18018 September 2024 Cover Letter - Issuance of Exemption Related to Non-Destructive Examination Compliance Regarding Sequoyah Nuclear Plant Independent Spent Fuel Storage Installation ML24253A0152024-09-0808 September 2024 Emergency Plan Implementing Procedure Revisions ML24247A2212024-08-29029 August 2024 Notification of Deviation from Pressurized Water Reactor Owners Group (PWROG) Letter OG-21-160, NEI 03-08 Needed Guidance: PWR Lower Radial Support Clevis Insert X-750 Bolt Inspection Requirements, September 1, 2021 ML24247A1802024-08-28028 August 2024 Application to Revise the Fuel Handling Accident Analysis, to Delete Technical Specification 3.9.4, Containment Penetrations, and to Modify Technical Specification 3.3.6, Containment Ventilation Isolation Instrumentation for Sequoyah Nuclea IR 05000327/20240052024-08-26026 August 2024 Updated Inspection Plan for Sequoyah Nuclear Plant, Units 1 and 2 - Report 05000327/2024005 and 05000328/2024005 ML24239A3972024-08-23023 August 2024 Rssc Wire & Cable LLC Dba Marmon - Part 21 Final Notification - 57243-EN 57243 CNL-24-061, Supplement to Application to Revise Function 5 of Technical Specification Table 3.3.2-1, ‘Engineered Safety Feature Actuation System Instrumentation,’ for the Sequoyah and Watts Bar (SQN-TS-23-02 and WBN-TS-23-08),2024-08-19019 August 2024 Supplement to Application to Revise Function 5 of Technical Specification Table 3.3.2-1, ‘Engineered Safety Feature Actuation System Instrumentation,’ for the Sequoyah and Watts Bar (SQN-TS-23-02 and WBN-TS-23-08), IR 05000327/20240022024-07-31031 July 2024 Integrated Inspection Report 05000327/2024002 and 05000328/2024002 ML24211A0572024-07-29029 July 2024 Submittal of Emergency Plan Implementing Procedure Revision ML24211A0542024-07-29029 July 2024 Operator License Examination Report ML24211A0412024-07-26026 July 2024 Unit 1 Cycle 26 Refueling Outage - 90-Day Inservice Inspection Summary Report ML24199A0012024-07-22022 July 2024 Clarification and Correction to Exemption from Requirement of 10 CFR 37.11(c)(2) ML24172A1342024-07-15015 July 2024 Exemptions from 10 CFR 37.11(C)(2) (EPID L-2023-LLE-0024) - Letter ML24191A4652024-07-0909 July 2024 Response to NRC Regulatory Issue Summary 2024-01, Preparation and Scheduling of Operator Licensing Examinations ML24177A0282024-06-25025 June 2024 Emergency Plan Implementing Procedure Revisions ML24176A0222024-06-24024 June 2024 Retraction of Interim Report of a Deviation or Failure to Comply – Transducer Model 8005N ML24089A1152024-06-21021 June 2024 Transmittal Letter, Environmental Assessments and Findings of No Significant Impact Related to Exemption Requests from 10 CFR 37.11(c)(2) ML24145A0852024-05-30030 May 2024 1B-B Diesel Generator Failure - Final Significance Determination Letter ML24145A1052024-05-29029 May 2024 301 Exam Approval Letter ML24134A1762024-05-13013 May 2024 Submittal of 2023 Annual Radiological Environmental Operating Report CNL-24-040, Tennessee Valley Authority - Central Emergency Control Center Emergency Plan Implementing Procedure Revisions2024-05-0808 May 2024 Tennessee Valley Authority - Central Emergency Control Center Emergency Plan Implementing Procedure Revisions ML24128A0352024-05-0707 May 2024 Providing Supplemental Information to Apparent Violation ML24120A0582024-04-26026 April 2024 10 CFR 50.46 Annual Report for Sequoyah Nuclear Plant Units 1 and 2 ML24116A2612024-04-25025 April 2024 Interim Report of a Deviation or Failure to Comply - Transducer Model 8005N ML24114A0482024-04-23023 April 2024 Annual Radioactive Effluent Release Report for 2023 Monitoring Period CNL-24-037, Clinch River, Sequoyah, Units 1 and 2, Watts Bar, Unit 1 and 2, Nuclear Quality Assurance Plan, TVA-NQA-PLN89-A, Revision 422024-04-22022 April 2024 Clinch River, Sequoyah, Units 1 and 2, Watts Bar, Unit 1 and 2, Nuclear Quality Assurance Plan, TVA-NQA-PLN89-A, Revision 42 ML24144A2362024-04-20020 April 2024 Discharge Monitoring Report (Dmr), March 2024 ML24144A2322024-04-20020 April 2024 Tennessee Multi-Sector Permit (Tmsp), 2024 Annual Discharge Monitoring Report for Outfalls SW-3, SW-3, and SW-9 ML24089A0882024-04-18018 April 2024 – Exemption from Select Requirements of 10 CFR Part 73; Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting ML24102A1212024-04-18018 April 2024 Summary of Conference Call with Tennessee Valley Authority Regarding Sequoyah Nuclear Plant, Unit 1 Spring 2024 Steam Generator Tube Inspections CNL-24-024, Hydrologic Engineering Center River Analysis System Project Milestone Status Update2024-04-17017 April 2024 Hydrologic Engineering Center River Analysis System Project Milestone Status Update CNL-24-033, Central Emergency Control Center Emergency Plan Implementing Procedure Revisions2024-04-17017 April 2024 Central Emergency Control Center Emergency Plan Implementing Procedure Revisions IR 05000327/20240012024-04-17017 April 2024 Integrated Inspection Report 05000327/2024001 and 05000328/2024001 ML24109A0272024-04-16016 April 2024 Cycle 27 Core Operating Limits Report Revision 0 CNL-23-006, Application to Modify Technical Specifications 3.8.1, AC Sources – Operating, and 3.8.2, AC Sources – Shutdown, for Sequoyah Nuclear Plant (SQN-TSC-22-03)2024-04-15015 April 2024 Application to Modify Technical Specifications 3.8.1, AC Sources – Operating, and 3.8.2, AC Sources – Shutdown, for Sequoyah Nuclear Plant (SQN-TSC-22-03) ML24106A0502024-04-12012 April 2024 Discharge Monitoring Report (Dmr), February 2024 2024-09-08
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION May 22, 2019
SUBJECT:
SEQUOYAH NUCLEAR PLANT, UNITS 1 AND 2 - U.S. NUCLEAR REGULATORY COMMISSION SECURITY INSPECTION REPORT 05000327/2019411 AND 05000328/2019411
Dear Mr. Shea:
On May 10, 2019, the U.S. Nuclear Regulatory Commission (NRC) completed a security baseline inspection at your Sequoyah Nuclear Station, Units 1, 2 and discussed the results of this inspection with Mr. M. Rasmussen and other members of your staff. The results of this inspection are documented in the enclosed report.
No NRC-Identified or self-revealing findings were identified during the inspections.
This letter will be made available for public inspection and copying at https://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room, in accordance with 10 CFR 2.390, Public Inspections, Exemptions, Requests for Withholding.
Sincerely,
/RA/
Binoy Desai, Chief Plant Support Branch Division of Reactor Safety Docket Nos. 50-327 and 50-328 License Nos. DPR-77 and DPR-79
Enclosure:
NRC IR 05000327/2019411 and 05000328/2019411
Inspection Report
Docket Nos: 05000327 and 05000328 License Nos: DPR-77 and DPR-79 Report Nos: 05000327/2019411 and 05000328/2019411 Enterprise Identifier: I-2019-411-003 Licensee: Tennessee Valley Authority Facility: Sequoyah Nuclear Station, Units 1 and 2 Location: Chattanooga, TN 37402 Dates: April 1-5, 2019 May 6-10, 2019 (In Office)
Inspectors: Jon Wallo, Senior Physical Security Inspector John Tornow, Physical Security Inspector Jonathan Brown, Physical Security Inspector Approved by: Binoy Desai, Chief Plant Support Branch Division of Reactor Safety Enclosure
SUMMARY
The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting a Baseline Security Inspection at Sequoyah Nuclear Station,
Units 1 and 2, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.
NRC and self-revealed findings, violations, and additional items are summarized in the table below.
List of Findings and Violations No findings were identified.
INSPECTION SCOPE
Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2201, Security Inspection Program for Commercial Nuclear Power Reactors. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.
SAFEGUARDS
71130.02 - Access Control
Main article: IP 71130.02
The inspectors evaluated the access control program. The following elements were evaluated from this IP dated January 1, 2019.
Tier I: all requirements Tier II: 8 requirements 02.06 (a-d), 02.07 (a), 02.08 (a), (e),
- (i) Tier III: 1 requirement 02.10 (a)
71130.04 - Equipment Performance, Testing, and Maintenance
Main article: IP 71130.04
The inspectors evaluated the security testing and maintenance program. The following elements were evaluated from this IP dated January 1, 2019.
Tier I: all 38 requirements Tier II: 4 requirements 02.09 (a); 02.12 (a); 02.13 (a),
- (d) Tier III: 2 requirements 02.14; 02.15 (a)
71130.07 - Security Training
Main article: IP 71130.07
The inspectors evaluated the nuclear security training program. The following elements were evaluated from this IP dated January 1, 2019.
Tier I: all 16 requirements Tier II: 8 requirements 02.05 (a), (b), (c), (d); 02.06 (a), (b); 02.09
- (a) Tier III: 5 requirements 02.10, 02.11(a); 02.13 (a), (b), (c)
OTHER ACTIVITIES - BASELINE
71151 - Performance Indicator Verification
The inspectors verified licensee performance indicators submittals listed below for the period from March 2018, through March 2019.
- (1) Protected Area Security Equipment Performance Index
EXIT MEETINGS AND DEBRIEFS
On May 10, 2019, the inspectors presented the Baseline Security Inspection results to Mr. M.
Rasmussen and other members of the licensee staff.
DOCUMENTS REVIEWED
Inspection Type Designation Description of Title Revision
Procecure & Date
71130.02 Procedures NPG-SPP-
14.10 Fitness-for-Duty- Alcohol and Drug Testing Requirements Rev. 4
NPG-SPP-
14.11 Fitness-for-Duty- Medical Review Officers Procedure Rev. 1
NPG-SPP-
14.12 Fitness-for-Duty-Intoxilyzers Requirements Rev. 4
NPG-SPP-
14.13 Fitness-for-Duty- Administrative Duties Rev. 3
NPG-SPP-14.3 Security Information Control Program Rev. 16
NPG-SPP-14.4 Nuclear Security Rev. 7
NPG-SPP-14.5 Access Authorization Rev. 18
NPG-SPP-14.6 Safety/Security Interface Rev. 7
NPG-SPP-14.7 National Threat Advisory System (SSI) Rev. 2
TVA Nuclear Power Group Nuclear Plant Site Check-In and Check-Out
BP-108 Process Rev. 24
NSDP-8 Keys and Locks Rev. 8
NSDP-17 Records Rev. 4
NSDP-23 Plant Access/Badging Process Rev. 19
NSDP-24 Access Authorization Program Rev. 14
NSDP-38 Access Authorization- Reviewing Officials Rev. 9
NSDP-46 Security Gas Mask Maintenance and Fit Testing Program Rev. 4
NSDP-49 Underground Pathway Rev. 0
NSDP-52 Quantitative Enzyme Diagnostic (QED) Saliva Alcohol Testing Rev. 1
SSI-7.3 Exterior Motor Patrol Rev. 29
SSI-7.5 Interior Foot Patrol Rev. 24
SSI-7.6 Personnel Access Control Rev. 40
SSI-7.7 Vehicle Access Control Rev. 43
SSI-7.10 Gate 56 Vehicle Access Rev. 4
71130.02 Procedures SSI-13.2 Sequoyah Nuclear Plant Law Enforcement Response Plan Rev. 4
SSI-14.1 Special Situations Affecting Security Rev. 5
SSI-16.1 Compensatory Measures Rev. 16
SSI-19.1 Temporary Suspension and/or Alteration of Security Measures Rev. 13
Guidance on the Protection of Unattended Openings that Intersect a
SSI-20.1 Security Boundary Rev. 4
SSI-27.1 Radioactive Material / Nuclear Fuel Receipt Rev. 3
SSI-29.1 Security Seals Rev. 3
71130.04 Procedures NPG-SPP-14.2 Target Set Development, Identification and Maintenance (SSI) Rev. 8
CTP-0-SEC-
FPI-623.W Card Reader and Balanced Magnetic Switch Operability Test Rev. 1
CTP-0-SEC-
FPI-625.S Card Reader and Hand Geometry Performance Test Rev. 0
CTP-0-SEC-
FPI-645.S Perimeter Intrusion Detection System Performance Test Rev. 1
CTP-0-SEC-
FPI-630.W Perimeter Intrusion Detection and CCTV Systems Operability Test Rev. 1
CTP-0-SEC-
FPI-643.W X-Ray Equipment Operability/Performance Test Rev. 2
CTP-0-SEC-
FPI-644.W Weekly Vehicle Barrier System Operational Test
CTP-0-SEC-
FPI-645.S Perimeter Intrusion Detection System Performance Test Rev. 1
CTP-0-SEC-
FPI-645.W Hand Held Metal Detector Operability/Performance Test
CTP-0-SEC-
FPI-646.W Walk Through Metal Detector Operability/Performance Test Rev. 1
CTP-0-SEC-
FPI-647.W Explosive Detector Operability/Performance Test Rev. 2
71130.04 Procedures CTP-0-SEC-
FPI-676.Q Owner Controlled, Protected, and Vital Barrier Inspection
CTP-0-SEC-
FPI-678.A Annual Vehicle Barrier System Inspection
CTP-0-SEC- CCTV System Preventative Maintenance Procedure Maintenance and
FPM-001 Functional Testing Rev. 2
CTP-0-SEC-
FPM-002 Annual Metal Detector Preventative Maintenance Rev. 1
CTP-0-SEC-
FPM-007 Explosive Detector Testing Rev. 0
SSI-7.1 Central and Secondary Alarm Stations Rev. 36
SSI-7.4 Bullet Resistant Enclosures / Semi-Static Posts Rev. 21
SSI-15.1 Testing and Maintenance Rev. 10
SSI-26.2 Response Equipment Inspection and Inventory Rev. 0
71130.07 Procedures BP-106 Administering NPG Medical Examination Process Rev. 4
NPG-SPP-14.1 Fitness for Duty Rev. 16
Guideline for Security Response to Indications of Tampering, Vandalism
NPG-SPP-14.8 and Malicious Mischief Rev. 2
NPG-SPP- Fitness-for-Duty- Training and Field Support for the Fitness of Duty
14.14 Program Rev. 3
NSDP-1 Safeguards Event Reporting Guideline Rev. 14
NSDP-4 Security Organization, Expectations and Standards Rev. 20
NSDP-18 Administration of Security Training Rev. 14
NSDP-22 Security Contingency Events (SGI) Rev. 6
NSDP-26 Weapons Accountability Rev. 19
NSDP-27 Conduct of Security Drills and Exercises/Performance Evaluation Program Rev. 15
71130.07 Procedures NSDP-30 Security Duty Restrictions/Return to Work Rev. 8
NSDP-32 TVA Nuclear Security Law Enforcement Plan Rev. 0
NSDP-39 Security Operating Experience Rev. 2
NSDP-40 Reporting of Non-Threat Security Events Rev. 2
NSDP-43 Safeguards Adjudication Rev. 3
NSDP-44 Graded Systematic Approach to Security Training (GSAST) Rev. 6
NSDP-44.1 Security On-The-Job Training Rev. 3
NSDP-44.2 Security Task Performance Evaluation Rev. 2
NSDP-45 Security Plan and Procedure Revision Process Rev. 1
NSDP-48 NPG Security Physical Fitness Test Rev. 3
TVA Nuclear Power Group Access Services Psychological Screening
NSDP-51 Manual Rev. 1
NSDP-53 Security Severe Weather Response Rev. 0
SSI-7.2 Protected Area Patrol Rev. 24
71151 Procedures NSDP-47 Evaluation of Security Related Issues Rev. 2
NSDP-29 Tracking and Trending and NRC Performance Indicators Rev. 9
71151 Condition 1435249
Reports 1463233
1481146
1488078
1491906
1434135
1403944
1405846
26570
1461494
1473982
1481621
71151 Corrective 1435249 The Security UPS HVAC needs to be repaired or replaced
Actions 1463233 Negative Trend associated with isolation zone LIU
1481146 Improper testing procedure use
1488078 Negative trend associated with isolation zone XX
1491906 Evaluate the elimination of PM 063601107
1383679 Key Core changout not completed within the specified timeframe
1462938
ACP gatehouse lane duress button should activate entry turnstile lockdown
Track training pertaining to the elimination of Security Support to
1405846 Maintenance
26570 Officers failed to complete LMS course requirements prior to attending
2nd.Trimester T/Q
71151 Corrective 1461494 Time stoppage while performing Task 27C
Actions 1473982 TVA Form 41104 - Administrative Error
SSA1903 Remediation Forms not in Training Records reviewed. No
1481621 Remediation form.
Corrective 1504377 Evaluate Key, Core and Lock Program
Actions 1504383 Use of Cover
Based on 1504384 Tester performed wrong test section
Inspection
1504816 Evaluate Barrier Deployment
1505374 Declining attitude for initiating CRs
1505586 Evaluate the FAC pertaining to assessing Exit alarm
1505588 Moving the jacks in the isolation zone while conducting testing
1505589 Drop down Arm at the Sally port is in need of attention
1505591 Evaluate revising procedure for prioritization of Security Equipment
9