IR 05000261/1981010

From kanterella
Jump to navigation Jump to search

IE Safety Insp Rept 50-261/81-10 on 810302-04.Noncompliance Noted:Failure to Perform Adequate Survey or Evaluation & Preserve Survey Records
ML14176A616
Person / Time
Site: Robinson, San Onofre  
Issue date: 04/10/1981
From: Hosey C, Wray J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML14176A615 List:
References
50-261-81-10, NUDOCS 8105270509
Download: ML14176A616 (8)


Text

/

QUNITED STATES NUCLEAR REGULATORY COMMISSION REGION il 101 MARIETTA ST., N.W., SUITE 3100 ATLANTA, GEORGIA 30303 Report No. 50-261/81-10 Licensee: Carolina Power and Light Company 411 Fayetteville Street Raleigh, NC 27602 Facility Name: H. B. Robinson Docket No. 50-261 License No. DPR-23 Inspection at H. B. Robinson site near Hartsville, South Carolina Inspector:

Jt Wray ate Signed Approved b C. M. ie ting ection Chief

/Dat Sighe Technical Inspectio Branch Engineering and Tec nical Inspection Division SUMMARY Inspected on March 2-4, 1981 Areas Inspected This special, announced inspection involved 22 inspector-hours onsite reviewing the licensee's evaluation of whole body doses received by personnel working inside steam generators during 198 Results Of the area inspected, three violations were identified (failure to perform an adequate survey or evaluation; exceeding quarterly whole body dose limit; and failure to maintain and preserve survey records).

810527

REPORT DETAILS 1. Persons Contacted Licensee Employees H. B. Starkey, Jr., General Manager

  • B. H. Webster, Manager -

Environmental and Radiation Control (Corporate)

  • 0. S. Crocker, E&RC Supervisor J. Pettigout, Senior ALARA Specialist B. MacCready, E&RC Engineer D. Gainey, RC&T Foreman E. Paine, Engineer Other Organizations F. E. Lesko, Senior Principal Engineer, Proto-Power Management Corporation NRC Resident Inspectors S. Weise, Resident Inspector J. Skolds, Senior Resident Inspector - V. C. Summer
  • Attended exit interview Exit Interview The inspection scope and findings were summarized on March 4, 1981 with

.those persons indicated in paragraph 1 above. The licensee representatives acknowledged the violations and indicated that all individuals whose dose records had been upgraded will be.notified pursuant to 10 CFR 19.13 whether or not their revised exposure exceeded regulatory limit.

Licensee Action. on Previous Inspection Findings Not inspecte.

Unresolved Items Unresolved items were not identified during this inspectio.

Summary of Events During review of the external radiation exposure control program while conducting the special Health Physics Appraisal inspection on January 26 February 6, 1981, the appraisal team examined individual exposure records, radiation survey data, and personnel monitoring techniques related to steam

generator tube plugging operations in 1980. Survey data showed that non uniform and complex radiation fields existed in both hot and cold leg sections of each steam generator (SG).

Personnel radiation monitoring consisted of thermoluminescent dosimeters (TLDs)

and self-reading pocket dosimeters (PDs)

enclosed in plastic bags and attached to the workers'

chests. A licensee representative acknowledged that an evaluation of the survey data did not generate sufficient concern to warrant use of extra dosimetry in the area of the worker's head and gonad The inspector stated that based on review of the available information, it appeared workers may have received a significantly greater whole body dose than previously recorded by dosimetry worn on their chest. On February 10, 1981 a Confirmation of Action Letter was issued to Carolina Power and Light documenting the licensee's commitment to reevaluate the radiation dose received by individuals who made entries into the steam generators during 198 The licensee contracted a consulting firm to (a) determine if the recorded exposure data was adequate; (b).determine the most appropriate method for evaluating whole body exposure if the recorded data was not adequate; and (c)

develop correction factors from existing data as appropriat The consultant's evaluation indicated that the exposure data recorded by the dosimetry worn by workers while inside SG channel heads did not reflect the whole body exposure actually received. The licensee concluded that avail able records could be used to develop correction factors for adjustments of recorded exposure data to properly reflect the actual whole body dos On February 19, the licensee notified the NRC regional office that prelimi nary calculations indicated two employees had received whole body occupa tional doses greater than 3 *ems in a.calendar quarter. These calculations were based on correction factors developed from extensive channel head survey dat The whole body dose recorded by personnel dosimetry worn on the chest during steam generator entries was adjusted for exposures which could have affected portions of the whole body other than the ches An inspector reviewed the licensee's calculations and methodology used in adjusting recorded doses. Licensee records indicated that 86 contract and station employees made steam generator channel head entries in 1980. Using the method developed by their consultant and incorporating comments by the inspector, the licensee concluded that the calculated dose for three indi viduals in 1980 exceeded 3 rems in one calendar quarte One individual received a total whole body dose of 3.054 rems in the first calendar quarter and two individuals received occupational doses of 3.124 rems and 3.257 rems in the third calendar quarter. The adjusted dose of a fourth individual, who had worked first at H. B. Robinson and then at Southern California Edison Company's San Onofre plant, disclosed that although his separate exposures at these two facilities did not exceed regulatory limits, his total occupational whole body dose during the second calendar quarter was greater than 3 rem No calculated occupational dose was more than 3.5 rems

in one calendar quarter and no individual exceeded established annual or lifetime exposure limit On March 30, 1981, CP&L management met with Region II management to discuss these overexposures and concerns about the exposure control program at the plant. During this meeting the violations were discussed and the enforce ment sanctions available to the NRC were disclosed to the license. Surveys and Dosimetry During 1980 four separate outages occurred involving steam generator main tenance work. The inspector reviewed with licensee representatives the available survey data of SG channel heads for each outag Dose rate survey information was taken with both TLDs and portable radiation survey instru ments. It included data at nine different points inside each channel head taken in accordance with health physics procedure HP-12,

"Steam Generator Inspection and Maintenance".

The nine points consisted of 3 points near the tubesheet, three general area points near mid level, and three points along the lower areas of the bow Licensee representatives stated that their evaluation of the data performed prior to the initial.steam generator entry of each outage concluded that dose rates were constant and relatively unifor As a result, only chest worn personnel dosimeters were authorize A review of the data shows that dose rates at the tube sheet and at the bottom of the bowl were up to 60% and 140% greater than at mid-level respectively where chest worn dosimeters normally would be located during a jum The inspector informed the licensee that failure to perform an adequate survey or evaluation of the radiation hazard incident to work inside the steam generators such that appropriate personnel monitoring devices were not provided to measure the dose received by worker's heads and gonads while inside the steam generators was a violation of 10 CFR 20.201 (50-261/81-10-01).

The inspector noted that a revision to HP-12 in January 1981, made the use of head and gonad dosimeters mandatory during future SG entrie This revision was in response to a Westinghouse letter recommending multi badging of workers in non-uniform radiation fields. The inspector concluded that the licensee, once informed of the potential for extremity exposures during steam generator entries, did act expeditiously to correct program inade quacies and provided measures to prevent future violations of regulatory dose limits. Although the licensee did act on his own volition to prevent recurrance, he did not reevaluate past exposure records unti.l requested by the NR. Methodology As a result of their reevaluation of SG survey data, the licensee concluded that exposure data recorded by chest-worn dosimetry did not reflect the whole body exposure actually received. The inspector discussed with licen see representatives the method used to adjust personnel exposure record This method was based on correction factors developed from the available survey data. The inspector was informed that alternate methods which were considered included computer modeling of the channel head environment and collection of empirical data during subsequent SG entrie The inspector agreed with the licensee that neither of these alternate methods would have produced significantly different result Computer modeling would have required extensive generalizations and simplifications and depended on the same survey data used in developing the correction factors employe Empirical data would have been difficult to correlate to past doses because of significant changes in the source term from one outage to anothe The approach employed was possible due to the availability of the extensive dose rate maps and detailed SG entry logs. The entry log included for each jump the duration, the TLD number, and the dose received as recorded by pocket dosimete For each survey performed in each channel head, the highest ratio between tube sheet and general area dose rates or channel head bowl and general area dose rates was determined. Ratios of dose rates from TLD surveys inside SG were equivalent to ratios obtained by portable radiation survey instruments. The inspector concluded from discussions with licensee representatives and observations of a simulated SG channel head survey conducted at the licensee's mock-up facility that the distance between survey points at the tubesheet and general area, and channel head bowl and general area were approximately 24 inches. The head and gonads are approximately 18 inches from the ches The licensee assumed that the chest TL was located in the general area and irradiated at dose rates recorded in this area on the survey maps. Since the distance between each survey point is greater than the distance between the chest and the head or gonads, the licensee reduced the highest ratios obtained by 25% in a linear manne The inspector agreed that a linear reduction is conservative compared to the dose reduction with distance from a finite plane sourc The inspector questioned the assumption that the chest worn TLD was posi tioned in the general area and the potential for self-body shielding of the chest area that would not occur for areas near the head or gonads. The SG mock-up was used to review body positions for the various job activities including installation and removal of nozzle covers and tubesheet templates, tube marking, and eddy current equipment and tube plugging operations. The inspector concluded from personal observations and reenactments of SG activities that the chest worn TLD could be assumed to have been positioned in the general area of the SG channel head with no significantly different results obtained. It was noted that the worst ratio between survey points was calculated, modified and applied to the total recorded occupational dose without regard for the amount of time spent in this worst positio The inspector also concluded that no significant self-body shielding of the chest worn TLD would have occurre The inspector questioned the potential dose to portions of the body other than the head or gonads and from beta radiatio Based on the extensive survey maps, it was concluded that the hand and foot dose limit of 18 3/4

rems per quarter was not exceede Results of several TLD badges used in survey map preparations showed insignificant beta dose contributio Protective clothing and respiratory protection requirements of HP-12 imply that the least protected parts of the skin is the skin on the face which, for each jumper, is shielded by at least a bubble hood with approximately 70 mg/sq cm density thickness. The inspector concluded that beta dose and dose to portions of the body other than the trunk, head or gonads do not appear to be of concern. However, it is recommended that the licensee formalize their evaluation techniques, calculations, and conclusions on beta, skin, extremity, and lens of the eye exposures during SG channel head work (50-261/81-10-02).

Once the adjusted ratios were determined, the dose received in each SG channel head, as measured by the chest TLD, was multiplied by the appro priate adjusted ratio. In those cases where the dose reported on a single TLD was received in separate SG channel heads as well as elsewhere onsite, the pocket dosimeter readings for each jump were used to determine how much dose was received in each channel head. The adjusted SG dose was added to other onsite dose and any prior offsite dose to determine the total quarterly whole body dos This calculation was performed for each individual who entered the SG channel heads in 1980 using the correction factors listed in Table All adjusted doses per jump were summed to determine the reported total quarterly occupational dos The calculations indicated that.one individual received a total whole body dose of 3.054 rems in the first calendar quarter and two individuals received occupational doses of 3.124 rems and 3.257 rems in the third calendar quarte The inspector informed the licensee that failure to limit the total quarterly occupational dose of each individual to 3 rems was a violation of 10 CFR 20.101 (50-261/81-10-03). Record Retention During the review of SG survey data for each outage, the inspector noticed that no dose rate information was available for the hot leg sections of all three steam generators for the September/October segment of the refueling outage. The. plant shut down in August at which time complete surveys of all SG were performed. Entries were made pursuant to health physics procedure HP-12 until late August when each SG was secured for fuel shuffling opera tions. Following this evolution, the SGs were reopened to complete tube plugging operation Based on discussions with licensee personnel and observation of other survey records, the inspector was convinced that complete surveys had been retaken on or before September 17, 1980, prior to additional channel head entrie However, only the survey maps for the cold leg sections of all three SG were retained on file. The inspector informed the licensee that failure to maintain survey records for the retention period specified in 10 CFR 20.401 was a violation (50-261/81-10-04).

0)

6 Training The inspector discussed the type and amount of training administered to workers prior to SG entries. The cognizant licensee representative stated that use of the mock-up steam generator is extensive. Dress out procedures are adhered to during practice jumps. Spare equipment is used to simulate job activities in the training environment. Photographs of the tube sheet plugging pattern are reviewed with appropriate personnel when neede The licensee acknowledged that no written record is maintained of this special ized job training. The inspector stated that although it appears that no requirement exists for special job training record retention, the licensee should develop and maintain records of all special training activities (50-261/81-10-05).

1 Conclusions The licensee's entry log, extensive survey data and administrative exposure limits for SG workers helped mitigate the severity of adjusted doses and limit the number of actual overexposure event The entry log contained information on each SG channel head entered including the duration of each entry, the TLD number of each jumper, and the dose he received as recorded by pocket dosimeter. Survey maps contained dose rate information at nine points inside the channel head Administrative exposure controls consisted of strict dose limits at which a worker's TLD must be processed or above which a worker could not be further expose TLDs are processed at approxi mately 1000 mrems and 2000 mrems. No individual is permitted to enter the SG if his cummulated quarterly whole body dose is above 2500 mre The maximum exposure allowed per jump based on survey data and stay time calculations is normally 50% of the difference between his existent dose and 2500 mrem Normally no individual is permitted to jump a SG if his quarterly dose would exceed 2500 mrem if he received 200 mrems during that jum As a result, correction calculations indicated that of 86 workers who entered SGs in 1980, 14 individuals received whole body doses greater than 2500 mrem in one calendar quarter. Of these, six employees received greater than 2750 mrem. Three of these six exceeded 3000 mrems in one calendar quarter. No occupational whole body dose for 1980 was greater than 3257 mrem in one calendar quarter. The inspector concluded that no safety or health hazard exists at the level of the doses involve TABLE 1 ADJUSTED RATIOS STEAM GENERATOR A

B C

Hot Leg Cold Leg Hot Leg Cold Leg Hot Leg Cold Leg 1)

March.91

--

--

1.42 2.05 2) April.32.25 1.04 1.04 3)

July 1.38 1.42

--

--

--

-

4) August 1.38 1.38 1.38 1.19 1.38 1.15 September 1.12*

1.12 1.45 1.25 1.50 1.25

  • Adjusted ratios obtained by assuming equivalent relative change of dose rates in H/L as had occurred in C/L.