- COMMITTEE ON WASHINGTON OFFICE ANKIt. FINANCE AND BulDING URBAN AFFAIRS 2238 Au Bu.DING HouawO orEPRESENTATIVES:
SUBCDMMITTrEZs WASNGTON. D.C.
20515 HOUSING
.TEnwO (202) 225-2965 INTERNATIONAL FINANCE INTERNATIONAL TRADE HOME OPPICE FEDERAL OFFICE BUILING COMM ITTEE ON 34CM Cmmk 0IA
- 9Z INTERIOR AND Civic INSULAR AFFAIRS
( 0tC gton E1Of SAWA All&, CAd" FO"^A 92701 UI.OMMES of~ t4h.L a nite %tat TMLM-OF: (714)'835-3811 SUBCOMMFTrTEES:
OVERSIGHT AN INVESTIGATIONS WATER AND POWER RESOURCES aootRpenaibs JERRY M. PATTERSON 38TH DISTRICT OF CALIFORNIA January 19, 1983 Mr. Nunzio J. Palladino Chairman, Nuclear Regulatory Commission Matomic Building 1717 H Street, N.W.
Washington DC, 20555
Dear Mr. Chairman:
On December 13, 1982, you appeared before the Sub committee on Oversight and Investigations of the House Com mittee on the Interior and Insular Affairs to discuss the issue of degradation of steam generator tubes at a number of nuclear power plants throughout the nation.
Unfortunately., I was unable to attend this session.
I would, however, like to direct some questions regarding steam generator leaks at the San Onofre Unit I power plant in southern California to you and your staff.
It is my understanding that in 1980, the owners of the San Onofre plant, Southern California Edison and San Diego Gas and Electric, found it necessary to sleeve approx imately 7,000 steam generator tubes at the Unit I plant because of severe degradation of the tubes.
In reference to this repair, I would like to know:
- 1) the causes of such degradation and, in the opinion of the Nuclear Regulatory Commission, the party or parties responsible for an occurence of this nature;
- 2) if, (given that the material used to sleeve the faulty tubes is similar in nature to the original tubing),
the Nuclear Regulatory Commission believes that sleeving is a permanent fix which will last the life of the plant;
- 3) if the Nuclear Regulatory Commission does consider sleeving to be a permanent fix, what technical studies have been done to support this position; 8303290241 830307 PDR CEOM NEC R
coRRSP
Mr. Nunzio J. Palladino January 19,.1983 Page two
- 4) if, with the problems of Unit I in mind, the steam generators in San Onofre Units II and III have been designed in such a manner that we can expect them to be trouble-free with respect to steam generator capability?
In addition to having these questions satisfac torily answered, I am very interested in being kept informed of any issues involving the San Onofre power plant.
Thank you in advance for assistance in this matter.
Cordially, JES M. PATTERSON U.S Congressman JMP:pbs