05000293/LER-1997-030, Forwards LER 97-030-00, Misapplication of FSAR Drywell Free Volume. Commitments Made within Ltr Listed

From kanterella
Jump to navigation Jump to search
Forwards LER 97-030-00, Misapplication of FSAR Drywell Free Volume. Commitments Made within Ltr Listed
ML20199F734
Person / Time
Site: Pilgrim
Issue date: 01/23/1998
From: Olivier L
BOSTON EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20199F737 List:
References
BECO-LTR.2.98.0, NUDOCS 9802040094
Download: ML20199F734 (1)


LER-2097-030, Forwards LER 97-030-00, Misapplication of FSAR Drywell Free Volume. Commitments Made within Ltr Listed
Event date:
Report date:
2932097030R00 - NRC Website

text

_ _ _ _ _ _ _ _ _

-1 10 CFR 50.73 Pihrim Nuclear Power Station

. ,, ~

Rocky Hiil Road Plymouth. Massachusetts 02360 b

L.J. Olivier Vice President Nuclear and Station Director January BECo l tr. 2.98.010 0

U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555 Docket No. 50-293 5, License NoJPR-35 The enclosect Licensee Event Report (LER) 97-030-00, " Misapplication of FSAR Drywell Free Volume,"is submitted in accordance with 10 CFR 50.73.

The following commitments are made in this letter.

. Resise FSAR Table 5.2.1 to clarify the listed drywell free volume value (March 30,1998),

e Complete the drywell volume calculations, M776 and M777 (February 28,1998).

Please do not hesitate to contact me if there are any questions regarding this report, J. Ol ier KRD/dcg

60. 97030000/ler cc: Mr. Hubert J. Miller ,

Regional Administrator, Region i U S. Nuclear Regulatory Commission 475 Allendale Road Khg of Prussia, PA 19406 Sr. NRC Resident inspector - Pilgrim Station Standard BECo LER Distribution ,/

m.m . , o llllillll.11 Illlil?

'900204009<~900123 ADOCK C5000293

)61 I PDR 8 PDRg

.. . ... . . .-.. - ___-_________ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _