Category:INSPECTION REPORT
MONTHYEARIR 05000482/19990091999-10-0707 October 1999 Insp Rept 50-482/99-09 on 990830-0903.No Violations Noted. Major Areas Inspected:Events,Emergency Preparedness Facilities & Equipment,Emergency Plan & Implementing Procedures & Emergency Response Organization Training IR 05000482/19990051999-09-21021 September 1999 Insp Rept 50-482/99-05 Has Been Rescheduled for Next Yr.Insp Rept Will Not Be Issued IR 05000482/19990131999-09-20020 September 1999 Insp Rept 50-482/99-13 on 990725-0904.Noncited Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19990121999-09-14014 September 1999 Insp Rept 50-482/99-12 on 990816-20.No Violations Noted. Major Areas Inspected:Solid Radioactive Waste Mgt Program, Radioactive Matls Transportation Program,Facilities & Equipment,Staff Kowledge & Performance & Staff Training IR 05000482/19990161999-08-26026 August 1999 Insp Rept 50-482/99-16 on 990809-13.No Violations Noted. Major Areas Inspected:Planning & Preparation,Program to Maintain Occupational Exposure Alara,Temporary Shielding Program & Hot Spot Reduction Program IR 05000482/19990081999-08-18018 August 1999 Insp Rept 50-482/99-08 on 990613-0724.Noncited Violation Identified.Major Areas Inspected:Operations,Maint & Plant Support IR 05000482/19990111999-08-13013 August 1999 Insp Rept 50-482/99-11 on 990712-16.No Violations Noted. Major Areas Inspected:Review of Radiological Environ Monitoring Program,Meterological Monitoring Prgram & Results of Licensee Investigation of 990525 Personnel Event IR 05000482/19990151999-08-10010 August 1999 Canceled Insp Rept 50-482/99-15.No Inspection Rept Will Be Issued for This Rept Number IR 05000482/19990071999-07-15015 July 1999 Insp Rept 50-482/99-07 on 990614-18.No Violations Noted. Major Areas Inspected:Routine Insp Reviewed Radiation Protection Program Activities IR 05000482/19990061999-07-0202 July 1999 Insp Rept 50-482/99-06 on 990502-0612.Two Violations Occurred & Being Treated as Noncited Violations.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19990031999-05-21021 May 1999 Insp Rept 50-482/99-03 on 990321-0501.Four NCVs Noted.Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000482/19990041999-05-0505 May 1999 Insp Rept 50-482/99-04 on 990405-09.No Violations Noted. Major Areas Inspected:Licensee Implementation of Facility Inservice Insp Program & Followup Review of Previously Identified Insp Findings IR 05000482/19990021999-04-0909 April 1999 Insp Rept 50-482/99-02 on 990207-0320.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19990011999-01-26026 January 1999 Insp Rept 50-482/99-01 on 990111-14.No Violations Noted. Major Areas Inspected:Testing & Maintenance,Protected Area Barriers & Detection Aids,Vital Area Barriers & Detection Aids,Compensatory Measures & Security Sys Power Supply IR 05000482/19980201999-01-15015 January 1999 Insp Rept 50-482/98-20 on 981115-1226.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000482/19980161998-12-10010 December 1998 Informs That Insp Rept 50-482/98-16 Was Combined with Insp Rept 50-482/98-12,therefore,no Rept Will Be Issued for Rept 50-482/98-16 ML20196H3711998-12-0303 December 1998 Insp Rept 50-482/98-19 on 981002-1114.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support.Licensee Response to Road Closure Due to Flooding within 10-mile Emergency Zone Was Excellent ML20155A1871998-10-22022 October 1998 Insp Rept 50-482/98-17 on 980823-1003.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support.Use of Fire Protection Sys Pumps for Purposes Other than Fire Protection Constituted Degradation of Sys IR 05000482/19980181998-10-0505 October 1998 Insp Rept 50-482/98-18 on 980921-25.No Violations Noted. Major Areas Inspected:Licensee Physical Security Program Including Access Authorization,Alarm Stations,Assessment Aids,Communications & Security Program Plan & Procedures ML20154C7071998-09-29029 September 1998 Insp Rept 50-482/98-12 on 980323-0410 & 0622-25.Violations Noted.Major Areas Inspected:Engineering & Plant Support IR 05000482/19980151998-09-0404 September 1998 Insp Rept 50-482/98-15 on 980712-0822.No Violations Noted. Major Areas Inspected:Operation,Maint,Engineering & Plant Support ML20236T1461998-07-23023 July 1998 Insp Rept 50-482/98-14 on 980531-0711.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19980131998-06-12012 June 1998 Insp Rept 50-482/98-13 on 980419-0530.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20216A9051998-05-0606 May 1998 Insp Rept 50-482/98-10 on 980308-0418.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20217M3691998-04-30030 April 1998 Insp Rept 50-482/98-07 on 980330-0403.No Violations Noted. Major Areas Inspected:Operational Status of Licensee Emergency Preparedness Program ML20217M5491998-04-0202 April 1998 Insp Rept 50-482/98-11 on 980316-20.Violations Noted.Major Areas Inspected:Implementation of Solid Radwaste Mgt & Radioactive Waste/Matls Transportation Programs IR 05000482/19980041998-04-0101 April 1998 Insp Rept 50-482/98-04 on 980125-0307.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19980081998-03-30030 March 1998 Insp Rept 50-482/98-08 on 980302-06.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support ML20216G5761998-03-13013 March 1998 Insp Rept 50-482/98-09 on 980223-27.Violation Noted.Major Areas Inspected:Radiation Protection Program IR 05000482/19980021998-03-0606 March 1998 Insp Rept 50-482/98-02 on 980202-06.No Violations Noted. Major Areas Inspected:Maint,Engineering & Emergency Preparedness IR 05000482/19980061998-02-27027 February 1998 Insp Rept 50-482/98-06 on 980202-06.No Violations Noted. Major Areas Inspected:Review of Radiation Protection Program Activities ML20203K9181998-02-26026 February 1998 Insp Rept 50-482/98-03 on 980202-06.No Violations Noted. Major Areas Inspected:Implementation of Liquid & Gaseous Radwaste Mgt Program,Training & Qualifications,Qa Oversight, Facilities & Equipment & Annual Repts ML20203H5341998-02-23023 February 1998 Insp Rept 50-482/97-201 on 971103-980109.No Violations Noted.Major Areas Inspected:Capability of RHR & CCW Sys to Perform Safety Functions Required by Design Bases & Adherence of Sys to Design & Licensing Bases IR 05000482/19970211998-02-0909 February 1998 Insp Rept 50-482/97-21 Cancelled IR 05000482/19970231998-01-29029 January 1998 Insp Rept 50-482/97-23 on 971214-980124.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19980011998-01-23023 January 1998 Insp Rept 50-482/98-01 on 980112-16.No Violation Noted. Major Areas Inspected:Licensee Physical Security Program, Including Protected Area Barriers & Detection Aids,Vital Area Barriers & Detection Aids & Compensatory Measures ML20198A7641997-12-29029 December 1997 Insp Rept 50-482/97-22 on 971102-1213.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19970191997-11-25025 November 1997 Insp Rept 50-482/97-19 on 970922-1102.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19970201997-11-14014 November 1997 Insp Rept 50-482/97-20 on 971020-24.Violations Noted.Major Areas Inspected:Planning & Preparation,External & Internal Exposure Controls,Control of Radioactive Material & Contamination,Training & Qualifications IR 05000482/19970171997-10-29029 October 1997 Insp Rept 50-482/97-17 on 970929-1010.No Violations Noted. Major Areas Inspected:Maint IR 05000482/19970151997-10-22022 October 1997 Insp Rept 50-482/97-15 on 970922-25.no Violations Noted. Major Areas Inspected:Radiological Protection & Chemistry Controls & Status of Radiological Protection & Chemistry Facilities & Equipment IR 05000482/19970161997-10-21021 October 1997 Insp Rept 50-482/97-16 on 971006-10.No Violations Noted. Major Areas Inspected:Licensee Physical Security Program Included Access Authorization,Alarm Stations,Communications, Access Control of Personnel & Packages IR 05000482/19970141997-10-0202 October 1997 Insp Rept 50-482/97-14 on 970810-0920.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19973011997-09-17017 September 1997 Insp Rept 50-482/97-301 on 970825-29.No Violations Noted. Major Areas Inspected:Operations IR 05000482/19970121997-09-0404 September 1997 Insp Rept 50-482/97-12 on 970811-15.No Violations Noted. Major Areas Inspected:Licensed Operator Requalification Program ML20210N6941997-08-21021 August 1997 Insp Rept 50-482/97-11 on 970629-0809.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20141J9561997-08-17017 August 1997 Insp Rept 50-482/97-13 on 970624-27 & 0708.No Violations Noted.Major Areas Inspected:Followup on licensee-identified Welding Work Control Issues by Observation of Welding & Welding Matl Control Activities ML20140E8511997-06-0606 June 1997 Insp Rept 50-482/97-09 on 970406-0517.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support,Re Violation Which Cites Licensee Failure to Comply W/Security Escort Requirements IR 05000482/19970031997-05-0202 May 1997 Insp Rept 50-482/97-03 on 970414-17.No Violations Noted. Major Areas Inspected:Operations ML20140E7261997-04-25025 April 1997 Insp Rept 50-482/97-08 on 970223-0405.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering, Plant Support & Plant Status 1999-09-21
[Table view] Category:NRC-GENERATED
MONTHYEARIR 05000482/19990091999-10-0707 October 1999 Insp Rept 50-482/99-09 on 990830-0903.No Violations Noted. Major Areas Inspected:Events,Emergency Preparedness Facilities & Equipment,Emergency Plan & Implementing Procedures & Emergency Response Organization Training IR 05000482/19990051999-09-21021 September 1999 Insp Rept 50-482/99-05 Has Been Rescheduled for Next Yr.Insp Rept Will Not Be Issued IR 05000482/19990131999-09-20020 September 1999 Insp Rept 50-482/99-13 on 990725-0904.Noncited Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19990121999-09-14014 September 1999 Insp Rept 50-482/99-12 on 990816-20.No Violations Noted. Major Areas Inspected:Solid Radioactive Waste Mgt Program, Radioactive Matls Transportation Program,Facilities & Equipment,Staff Kowledge & Performance & Staff Training IR 05000482/19990161999-08-26026 August 1999 Insp Rept 50-482/99-16 on 990809-13.No Violations Noted. Major Areas Inspected:Planning & Preparation,Program to Maintain Occupational Exposure Alara,Temporary Shielding Program & Hot Spot Reduction Program IR 05000482/19990081999-08-18018 August 1999 Insp Rept 50-482/99-08 on 990613-0724.Noncited Violation Identified.Major Areas Inspected:Operations,Maint & Plant Support IR 05000482/19990111999-08-13013 August 1999 Insp Rept 50-482/99-11 on 990712-16.No Violations Noted. Major Areas Inspected:Review of Radiological Environ Monitoring Program,Meterological Monitoring Prgram & Results of Licensee Investigation of 990525 Personnel Event IR 05000482/19990151999-08-10010 August 1999 Canceled Insp Rept 50-482/99-15.No Inspection Rept Will Be Issued for This Rept Number IR 05000482/19990071999-07-15015 July 1999 Insp Rept 50-482/99-07 on 990614-18.No Violations Noted. Major Areas Inspected:Routine Insp Reviewed Radiation Protection Program Activities IR 05000482/19990061999-07-0202 July 1999 Insp Rept 50-482/99-06 on 990502-0612.Two Violations Occurred & Being Treated as Noncited Violations.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19990031999-05-21021 May 1999 Insp Rept 50-482/99-03 on 990321-0501.Four NCVs Noted.Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000482/19990041999-05-0505 May 1999 Insp Rept 50-482/99-04 on 990405-09.No Violations Noted. Major Areas Inspected:Licensee Implementation of Facility Inservice Insp Program & Followup Review of Previously Identified Insp Findings IR 05000482/19990021999-04-0909 April 1999 Insp Rept 50-482/99-02 on 990207-0320.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19990011999-01-26026 January 1999 Insp Rept 50-482/99-01 on 990111-14.No Violations Noted. Major Areas Inspected:Testing & Maintenance,Protected Area Barriers & Detection Aids,Vital Area Barriers & Detection Aids,Compensatory Measures & Security Sys Power Supply IR 05000482/19980201999-01-15015 January 1999 Insp Rept 50-482/98-20 on 981115-1226.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000482/19980161998-12-10010 December 1998 Informs That Insp Rept 50-482/98-16 Was Combined with Insp Rept 50-482/98-12,therefore,no Rept Will Be Issued for Rept 50-482/98-16 ML20196H3711998-12-0303 December 1998 Insp Rept 50-482/98-19 on 981002-1114.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support.Licensee Response to Road Closure Due to Flooding within 10-mile Emergency Zone Was Excellent ML20155A1871998-10-22022 October 1998 Insp Rept 50-482/98-17 on 980823-1003.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support.Use of Fire Protection Sys Pumps for Purposes Other than Fire Protection Constituted Degradation of Sys IR 05000482/19980181998-10-0505 October 1998 Insp Rept 50-482/98-18 on 980921-25.No Violations Noted. Major Areas Inspected:Licensee Physical Security Program Including Access Authorization,Alarm Stations,Assessment Aids,Communications & Security Program Plan & Procedures ML20154C7071998-09-29029 September 1998 Insp Rept 50-482/98-12 on 980323-0410 & 0622-25.Violations Noted.Major Areas Inspected:Engineering & Plant Support IR 05000482/19980151998-09-0404 September 1998 Insp Rept 50-482/98-15 on 980712-0822.No Violations Noted. Major Areas Inspected:Operation,Maint,Engineering & Plant Support ML20236T1461998-07-23023 July 1998 Insp Rept 50-482/98-14 on 980531-0711.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19980131998-06-12012 June 1998 Insp Rept 50-482/98-13 on 980419-0530.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20216A9051998-05-0606 May 1998 Insp Rept 50-482/98-10 on 980308-0418.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20217M3691998-04-30030 April 1998 Insp Rept 50-482/98-07 on 980330-0403.No Violations Noted. Major Areas Inspected:Operational Status of Licensee Emergency Preparedness Program ML20217M5491998-04-0202 April 1998 Insp Rept 50-482/98-11 on 980316-20.Violations Noted.Major Areas Inspected:Implementation of Solid Radwaste Mgt & Radioactive Waste/Matls Transportation Programs IR 05000482/19980041998-04-0101 April 1998 Insp Rept 50-482/98-04 on 980125-0307.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19980081998-03-30030 March 1998 Insp Rept 50-482/98-08 on 980302-06.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support ML20216G5761998-03-13013 March 1998 Insp Rept 50-482/98-09 on 980223-27.Violation Noted.Major Areas Inspected:Radiation Protection Program IR 05000482/19980021998-03-0606 March 1998 Insp Rept 50-482/98-02 on 980202-06.No Violations Noted. Major Areas Inspected:Maint,Engineering & Emergency Preparedness IR 05000482/19980061998-02-27027 February 1998 Insp Rept 50-482/98-06 on 980202-06.No Violations Noted. Major Areas Inspected:Review of Radiation Protection Program Activities ML20203K9181998-02-26026 February 1998 Insp Rept 50-482/98-03 on 980202-06.No Violations Noted. Major Areas Inspected:Implementation of Liquid & Gaseous Radwaste Mgt Program,Training & Qualifications,Qa Oversight, Facilities & Equipment & Annual Repts ML20203H5341998-02-23023 February 1998 Insp Rept 50-482/97-201 on 971103-980109.No Violations Noted.Major Areas Inspected:Capability of RHR & CCW Sys to Perform Safety Functions Required by Design Bases & Adherence of Sys to Design & Licensing Bases IR 05000482/19970211998-02-0909 February 1998 Insp Rept 50-482/97-21 Cancelled IR 05000482/19970231998-01-29029 January 1998 Insp Rept 50-482/97-23 on 971214-980124.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19980011998-01-23023 January 1998 Insp Rept 50-482/98-01 on 980112-16.No Violation Noted. Major Areas Inspected:Licensee Physical Security Program, Including Protected Area Barriers & Detection Aids,Vital Area Barriers & Detection Aids & Compensatory Measures ML20198A7641997-12-29029 December 1997 Insp Rept 50-482/97-22 on 971102-1213.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19970191997-11-25025 November 1997 Insp Rept 50-482/97-19 on 970922-1102.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19970201997-11-14014 November 1997 Insp Rept 50-482/97-20 on 971020-24.Violations Noted.Major Areas Inspected:Planning & Preparation,External & Internal Exposure Controls,Control of Radioactive Material & Contamination,Training & Qualifications IR 05000482/19970171997-10-29029 October 1997 Insp Rept 50-482/97-17 on 970929-1010.No Violations Noted. Major Areas Inspected:Maint IR 05000482/19970151997-10-22022 October 1997 Insp Rept 50-482/97-15 on 970922-25.no Violations Noted. Major Areas Inspected:Radiological Protection & Chemistry Controls & Status of Radiological Protection & Chemistry Facilities & Equipment IR 05000482/19970161997-10-21021 October 1997 Insp Rept 50-482/97-16 on 971006-10.No Violations Noted. Major Areas Inspected:Licensee Physical Security Program Included Access Authorization,Alarm Stations,Communications, Access Control of Personnel & Packages IR 05000482/19970141997-10-0202 October 1997 Insp Rept 50-482/97-14 on 970810-0920.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19973011997-09-17017 September 1997 Insp Rept 50-482/97-301 on 970825-29.No Violations Noted. Major Areas Inspected:Operations IR 05000482/19970121997-09-0404 September 1997 Insp Rept 50-482/97-12 on 970811-15.No Violations Noted. Major Areas Inspected:Licensed Operator Requalification Program ML20210N6941997-08-21021 August 1997 Insp Rept 50-482/97-11 on 970629-0809.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20141J9561997-08-17017 August 1997 Insp Rept 50-482/97-13 on 970624-27 & 0708.No Violations Noted.Major Areas Inspected:Followup on licensee-identified Welding Work Control Issues by Observation of Welding & Welding Matl Control Activities ML20140E8511997-06-0606 June 1997 Insp Rept 50-482/97-09 on 970406-0517.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support,Re Violation Which Cites Licensee Failure to Comply W/Security Escort Requirements IR 05000482/19970031997-05-0202 May 1997 Insp Rept 50-482/97-03 on 970414-17.No Violations Noted. Major Areas Inspected:Operations ML20140E7261997-04-25025 April 1997 Insp Rept 50-482/97-08 on 970223-0405.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering, Plant Support & Plant Status 1999-09-21
[Table view] Category:INSPECTION REPORT
MONTHYEARIR 05000482/19990091999-10-0707 October 1999 Insp Rept 50-482/99-09 on 990830-0903.No Violations Noted. Major Areas Inspected:Events,Emergency Preparedness Facilities & Equipment,Emergency Plan & Implementing Procedures & Emergency Response Organization Training IR 05000482/19990051999-09-21021 September 1999 Insp Rept 50-482/99-05 Has Been Rescheduled for Next Yr.Insp Rept Will Not Be Issued IR 05000482/19990131999-09-20020 September 1999 Insp Rept 50-482/99-13 on 990725-0904.Noncited Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19990121999-09-14014 September 1999 Insp Rept 50-482/99-12 on 990816-20.No Violations Noted. Major Areas Inspected:Solid Radioactive Waste Mgt Program, Radioactive Matls Transportation Program,Facilities & Equipment,Staff Kowledge & Performance & Staff Training IR 05000482/19990161999-08-26026 August 1999 Insp Rept 50-482/99-16 on 990809-13.No Violations Noted. Major Areas Inspected:Planning & Preparation,Program to Maintain Occupational Exposure Alara,Temporary Shielding Program & Hot Spot Reduction Program IR 05000482/19990081999-08-18018 August 1999 Insp Rept 50-482/99-08 on 990613-0724.Noncited Violation Identified.Major Areas Inspected:Operations,Maint & Plant Support IR 05000482/19990111999-08-13013 August 1999 Insp Rept 50-482/99-11 on 990712-16.No Violations Noted. Major Areas Inspected:Review of Radiological Environ Monitoring Program,Meterological Monitoring Prgram & Results of Licensee Investigation of 990525 Personnel Event IR 05000482/19990151999-08-10010 August 1999 Canceled Insp Rept 50-482/99-15.No Inspection Rept Will Be Issued for This Rept Number IR 05000482/19990071999-07-15015 July 1999 Insp Rept 50-482/99-07 on 990614-18.No Violations Noted. Major Areas Inspected:Routine Insp Reviewed Radiation Protection Program Activities IR 05000482/19990061999-07-0202 July 1999 Insp Rept 50-482/99-06 on 990502-0612.Two Violations Occurred & Being Treated as Noncited Violations.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19990031999-05-21021 May 1999 Insp Rept 50-482/99-03 on 990321-0501.Four NCVs Noted.Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000482/19990041999-05-0505 May 1999 Insp Rept 50-482/99-04 on 990405-09.No Violations Noted. Major Areas Inspected:Licensee Implementation of Facility Inservice Insp Program & Followup Review of Previously Identified Insp Findings IR 05000482/19990021999-04-0909 April 1999 Insp Rept 50-482/99-02 on 990207-0320.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19990011999-01-26026 January 1999 Insp Rept 50-482/99-01 on 990111-14.No Violations Noted. Major Areas Inspected:Testing & Maintenance,Protected Area Barriers & Detection Aids,Vital Area Barriers & Detection Aids,Compensatory Measures & Security Sys Power Supply IR 05000482/19980201999-01-15015 January 1999 Insp Rept 50-482/98-20 on 981115-1226.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000482/19980161998-12-10010 December 1998 Informs That Insp Rept 50-482/98-16 Was Combined with Insp Rept 50-482/98-12,therefore,no Rept Will Be Issued for Rept 50-482/98-16 ML20196H3711998-12-0303 December 1998 Insp Rept 50-482/98-19 on 981002-1114.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support.Licensee Response to Road Closure Due to Flooding within 10-mile Emergency Zone Was Excellent ML20155A1871998-10-22022 October 1998 Insp Rept 50-482/98-17 on 980823-1003.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support.Use of Fire Protection Sys Pumps for Purposes Other than Fire Protection Constituted Degradation of Sys IR 05000482/19980181998-10-0505 October 1998 Insp Rept 50-482/98-18 on 980921-25.No Violations Noted. Major Areas Inspected:Licensee Physical Security Program Including Access Authorization,Alarm Stations,Assessment Aids,Communications & Security Program Plan & Procedures ML20154C7071998-09-29029 September 1998 Insp Rept 50-482/98-12 on 980323-0410 & 0622-25.Violations Noted.Major Areas Inspected:Engineering & Plant Support IR 05000482/19980151998-09-0404 September 1998 Insp Rept 50-482/98-15 on 980712-0822.No Violations Noted. Major Areas Inspected:Operation,Maint,Engineering & Plant Support ML20236T1461998-07-23023 July 1998 Insp Rept 50-482/98-14 on 980531-0711.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19980131998-06-12012 June 1998 Insp Rept 50-482/98-13 on 980419-0530.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20216A9051998-05-0606 May 1998 Insp Rept 50-482/98-10 on 980308-0418.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20217M3691998-04-30030 April 1998 Insp Rept 50-482/98-07 on 980330-0403.No Violations Noted. Major Areas Inspected:Operational Status of Licensee Emergency Preparedness Program ML20217M5491998-04-0202 April 1998 Insp Rept 50-482/98-11 on 980316-20.Violations Noted.Major Areas Inspected:Implementation of Solid Radwaste Mgt & Radioactive Waste/Matls Transportation Programs IR 05000482/19980041998-04-0101 April 1998 Insp Rept 50-482/98-04 on 980125-0307.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19980081998-03-30030 March 1998 Insp Rept 50-482/98-08 on 980302-06.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support ML20216G5761998-03-13013 March 1998 Insp Rept 50-482/98-09 on 980223-27.Violation Noted.Major Areas Inspected:Radiation Protection Program IR 05000482/19980021998-03-0606 March 1998 Insp Rept 50-482/98-02 on 980202-06.No Violations Noted. Major Areas Inspected:Maint,Engineering & Emergency Preparedness IR 05000482/19980061998-02-27027 February 1998 Insp Rept 50-482/98-06 on 980202-06.No Violations Noted. Major Areas Inspected:Review of Radiation Protection Program Activities ML20203K9181998-02-26026 February 1998 Insp Rept 50-482/98-03 on 980202-06.No Violations Noted. Major Areas Inspected:Implementation of Liquid & Gaseous Radwaste Mgt Program,Training & Qualifications,Qa Oversight, Facilities & Equipment & Annual Repts ML20203H5341998-02-23023 February 1998 Insp Rept 50-482/97-201 on 971103-980109.No Violations Noted.Major Areas Inspected:Capability of RHR & CCW Sys to Perform Safety Functions Required by Design Bases & Adherence of Sys to Design & Licensing Bases IR 05000482/19970211998-02-0909 February 1998 Insp Rept 50-482/97-21 Cancelled IR 05000482/19970231998-01-29029 January 1998 Insp Rept 50-482/97-23 on 971214-980124.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19980011998-01-23023 January 1998 Insp Rept 50-482/98-01 on 980112-16.No Violation Noted. Major Areas Inspected:Licensee Physical Security Program, Including Protected Area Barriers & Detection Aids,Vital Area Barriers & Detection Aids & Compensatory Measures ML20198A7641997-12-29029 December 1997 Insp Rept 50-482/97-22 on 971102-1213.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19970191997-11-25025 November 1997 Insp Rept 50-482/97-19 on 970922-1102.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19970201997-11-14014 November 1997 Insp Rept 50-482/97-20 on 971020-24.Violations Noted.Major Areas Inspected:Planning & Preparation,External & Internal Exposure Controls,Control of Radioactive Material & Contamination,Training & Qualifications IR 05000482/19970171997-10-29029 October 1997 Insp Rept 50-482/97-17 on 970929-1010.No Violations Noted. Major Areas Inspected:Maint IR 05000482/19970151997-10-22022 October 1997 Insp Rept 50-482/97-15 on 970922-25.no Violations Noted. Major Areas Inspected:Radiological Protection & Chemistry Controls & Status of Radiological Protection & Chemistry Facilities & Equipment IR 05000482/19970161997-10-21021 October 1997 Insp Rept 50-482/97-16 on 971006-10.No Violations Noted. Major Areas Inspected:Licensee Physical Security Program Included Access Authorization,Alarm Stations,Communications, Access Control of Personnel & Packages IR 05000482/19970141997-10-0202 October 1997 Insp Rept 50-482/97-14 on 970810-0920.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19973011997-09-17017 September 1997 Insp Rept 50-482/97-301 on 970825-29.No Violations Noted. Major Areas Inspected:Operations IR 05000482/19970121997-09-0404 September 1997 Insp Rept 50-482/97-12 on 970811-15.No Violations Noted. Major Areas Inspected:Licensed Operator Requalification Program ML20210N6941997-08-21021 August 1997 Insp Rept 50-482/97-11 on 970629-0809.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20141J9561997-08-17017 August 1997 Insp Rept 50-482/97-13 on 970624-27 & 0708.No Violations Noted.Major Areas Inspected:Followup on licensee-identified Welding Work Control Issues by Observation of Welding & Welding Matl Control Activities ML20140E8511997-06-0606 June 1997 Insp Rept 50-482/97-09 on 970406-0517.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support,Re Violation Which Cites Licensee Failure to Comply W/Security Escort Requirements IR 05000482/19970031997-05-0202 May 1997 Insp Rept 50-482/97-03 on 970414-17.No Violations Noted. Major Areas Inspected:Operations ML20140E7261997-04-25025 April 1997 Insp Rept 50-482/97-08 on 970223-0405.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering, Plant Support & Plant Status 1999-09-21
[Table view] Category:UTILITY
MONTHYEARML20058B2871990-10-23023 October 1990 Insp Rept 50-482/90-34 on 900926-1005.Violations Noted. Major Areas Inspected:Followup of 891102 Event IR 05000482/19900281990-09-28028 September 1990 Insp Rept 50-482/90-28 on 900701-31.Violations Noted.Major Areas Inspected:Plant Status,Monthly Surveillance & Maint Observation,Operational Safety Verification & Onsite Followup of Events IR 05000482/19900301990-09-26026 September 1990 Insp Rept 50-482/90-30 on 900730-0810.Violation Noted But Not Cited ML20056A2891990-07-30030 July 1990 Insp Rept 50-482/90-26 on 900601-30.Violations Noted.Major Areas Inspected:Plant Status,Operational Safety Verification,Monthly Surveillance Observation,Monthly Maint Observation & Plant Startup from Refueling IR 05000482/19900231990-07-25025 July 1990 Partially Withheld Physical Security Insp Rept 50-482/90-23 on 900507-11 & 0629-0703 (Ref 10CFR73.21).Violation Noted. Major Areas Inspected:Followup on Previous Insp Findings,Mgt Support,Security Program Plan & Audits & Alarm Stations IR 05000482/19900251990-07-0202 July 1990 Insp Rept 50-482/90-25 on 900611-15.No Violations or Deviations Noted.One Unresolved Item Noted.Major Areas inspected:post-fire Safe Shutdown Capability Reverification & Assessment of Fire Protection Program Compliance W/App R IR 05000482/19900221990-06-29029 June 1990 Insp Rept 50-482/90-22 on 900501-31.Noncited Violation Noted.One Unresolved Item Identified.Major Areas Inspected: Plant Status,Operational Safety Verification,Monthly Maint & Surveillance Observation & Refueling Activities IR 05000482/19900271990-06-15015 June 1990 Insp Rept 50-482/90-27 on 900604-08.No Violations or Deviations Noted.Major Areas Inspected:Facility Mods ML20058K3711990-06-15015 June 1990 Insp Rept 50-482/90-24 on 900514-18.Violation Noted.Major Areas Inspected:Operational Status of Emergency Preparedness Program,Including Changes to EPIPs & Review of Emergency Facilities IR 05000482/19890251989-09-26026 September 1989 Insp Rept 50-482/89-25 on 890911-15.No Violations Noted. Major Areas Inspected:Licensee Submitted Relief Requests & Current Status,Administrative Controls & Procedures,Maint Records & Postmaint Testing & Surveillance Testing of Pumps IR 05000482/19890221989-09-18018 September 1989 Insp Rept 50-482/89-22 on 890828-0901.No Violations Noted. Major Areas Inspected:Surveillance Procedures & Records & Followup of Previous Insp Findings IR 05000482/19890231989-09-14014 September 1989 Insp Rept 50-482/89-23 on 890801-31.Violation Noted.Major Areas Inspected:Plant Status,Onsite Followup of Events at Operating Power Reactors,Operational Safety Verification, Monthly Surveillance & Maint Observation & Part 21 Repts IR 05000482/19890211989-08-0707 August 1989 Insp Rept 50-482/89-21 on 890701-31.No Violations or Deviations.Major Areas Inspected:Plant Status,Operational Safety Verification,Monthly Maint & Surveillance Observation & Onsite Followup of Events IR 05000482/19890171989-07-21021 July 1989 Insp Rept 50-482/89-17 on 890626-0706.No Violations or Deviations Noted.Major Areas Inspected:Licensees Actions to Prevent & Respond to Loss of DHR as Described in Generic Ltr 88-17 IR 05000482/19890181989-07-17017 July 1989 Insp Rept 50-482/89-18 on 890626-30.No Violations or Deviations Noted.Major Areas Inspected:Storage of Emergency Diesel Generator Fuel Oil,Containment Bldg Temp Profiles, LERs & Target Rock Solenoid Valves IR 05000482/19890151989-06-23023 June 1989 Insp Rept 50-482/89-15 on 890501-31.Violation Noted.Major Areas Inspected:Plant Status,Followup on Previous NRC Identified Items,Operational Safety Verification,Monthly Surveillance Observation & Monthly Maint Observation IR 05000482/19890131989-05-11011 May 1989 Insp Rept 50-482/89-13 on 890401-30.No Violations Noted. Major Areas Inspected:Plant Status,Operational Safety Verification,Monthly Surveillance Observation & Monthly Maint Observation IR 05000482/19890101989-05-0505 May 1989 Insp Rept 50-482/89-10 on 890301-31.No Violations or Deviations Noted.Major Areas Inspected:Plant Status, Operational Safety Verification,Monthly Surveillance Observation & Balance of Plant ML20245J4251989-04-21021 April 1989 Insp Rept 50-482/89-05 on 890201-28.Violations Noted.Major Areas Inspected:Plant Status,Followup on Previously Identified NRC Items,Operational Safety Verification,Monthly Surveillance Observation & Monthly Maint Observation IR 05000482/19890091989-04-13013 April 1989 Insp Rept 50-482/89-09 on 890313-17.Violations Noted.Major Areas Inspected:Licensee Liquid & Gaseous Radwaste Mgt Programs & Occupational Radiation Exposure Control Program IR 05000482/19890081989-04-10010 April 1989 Insp Rept 50-482/89-08 on 890306-10.Violations Noted.Major Areas Inspected:Previous Insp Findings & SSOMI Items.Greater Mgt Involvement in Strengthening Attention to Detail Re Procedure Implementation & Facility Changes Needed IR 05000482/19890111989-03-27027 March 1989 Advises That Insp Rept 50-482/89-11 Has Been Cancelled & No Insp Rept Will Be Issued IR 05000482/19890061989-03-0707 March 1989 Insp Rept 50-482/89-06 on 890130-0202.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness Program,Including Changes to Emergency Plan & Implementing Procedures & Revised Emergency Action Levels IR 05000482/19890071989-03-0707 March 1989 Insp Rept 50-482/89-07 on 890213-17.Violations Noted.Major Areas Inspected:Facility Mods & Offsite Technical Support ML20236C4961989-03-0202 March 1989 Partially Withheld Insp Rept 50-482/89-12 on 890130-0203 (Ref 10CFR73.21).Violation Noted.Major Areas Inspected: Physical Security Program,Including Mgt Support,Ler Followup,Security Program Plan & Audits & Physical Barriers IR 05000482/19890031989-02-16016 February 1989 Insp Rept 50-482/89-03 on 890109-13.No Violations or Deviations Noted.Adverse Affects of Decisions Re Exchange of Firearms Discussed.Major Areas Inspected:Physical Security Program,Including Mgt Support & LER Followup IR 05000482/19880331988-10-28028 October 1988 Insp Rept 50-482/88-33 on 881011-15.No Violations or Deviations Noted.Major Areas Inspected:Containment Integrated Leak Rate Test IR 05000482/19880241988-10-27027 October 1988 Insp Rept 50-482/88-24 on 880901-30.No Violations Noted. Major Areas Inspected:Plant Status,Followup on Previously Identified NRC Item,Review of Lers,Operational Safety Verification & Physical Security Verification IR 05000482/19880231988-10-21021 October 1988 Insp Rept 50-482/88-23 on 880829-0902.No Violations Noted. Major Areas Inspected:Followup to Previous Insp Findings & LERs,10CFR21 Repts & Safety Sys Outage Mod Insp IR 05000482/19880281988-10-20020 October 1988 Insp Rept 50-482/88-28 on 880919-23.Violation Noted.Major Areas Inspected:Licensee Chemistry/Radiochemistry Program & Water Chemistry Confirmatory Measurements IR 05000482/19880261988-10-14014 October 1988 Insp Rept 50-482/88-26 on 880926-30.No Violations or Deviations Noted.Major Areas Inspected:Inservice Insp Program & Procedures,Welding & NDE Procedures & Program for Control of Design Changes & Mods IR 05000482/19880251988-10-13013 October 1988 Insp Rept 50-482/88-25 on 880912-16.Violations Noted.No Deviations Noted.Major Areas Inspected:Radiation Protection Program & Planning Activities for Forthcoming Refueling Outage IR 05000482/19880291988-10-13013 October 1988 Partially Withheld Insp Rept 50-482/88-29 on 880927-29 (Ref 10CFR73.21).Violation Noted.Major Areas Inspected:Physical Security Plan & Implementing Procedures,Security Program Audits & Matls Control & Accountability IR 05000482/19880221988-09-22022 September 1988 Insp Rept 50-482/88-22 on 880801-31.One Violation Noted. Major Areas Inspected:Plant Status,Operational Safety Verification,Monthly Surveillance Observation,Monthly Maint Observation,Onsite Event Followup & Physical Security ML20154G8641988-09-16016 September 1988 Insp Rept 50-482/88-200 on 880606-17.Potential Enforcement Findings & Observations Noted.Major Areas Inspected:Line Organization Support & Contribution to Plant Quality & Quality Verification Organization Abilities Re Deficiencies IR 05000482/19880211988-08-17017 August 1988 Insp Rept 50-482/88-21 on 880711-15.Violation Noted.Major Areas Inspected:Nonlicensed Staff Training Program,Licensed Operator Training Program & Related Followup Items ML20207E9771988-08-11011 August 1988 Insp Rept 50-482/88-20 on 880701-31.No Violations or Deviations Noted.Major Areas Inspected:Plant Status, Operational Safety Verification,Monthly Surveillance Observation & Physical Security Verification IR 05000482/19880191988-07-29029 July 1988 Insp Rept 50-482/88-19 on 880515-0630.Violation Noted.Major Areas Inspected:Plant Status,Allegation followup,10CFR21 Rept Followup,Operational Safety Verification,Monthly Surveillance Observation & Physical Security Verification IR 05000482/19880161988-06-16016 June 1988 Insp Rept 50-482/88-16 on 880401-0514.No Violations or Deviations Noted.Major Areas Inspected:Followup of Previous Insp Findings, Monthly Surveillance & Maint Observation, Operational Safety Verification & Onsite Event Followup IR 05000482/19880171988-06-0606 June 1988 Insp Rept 50-482/88-17 on 880502-06.Violations Noted.Major Areas Inspected:Activities Associated W/Followup to Licensee Event Reporting,Mod Testing & Surveillance Procedures & Records IR 05000482/19880131988-05-10010 May 1988 Insp Rept 50-482/88-13 on 880314-0406.Violations Noted.Major Areas Inspected:Correctness of Emergency Operating Procedures & Meaningful Accomplishment Using Existing Equipment & Controls & Instrumentation IR 05000482/19880151988-05-0606 May 1988 Insp Rept 50-482/88-15 on 880328-0401.Violations Noted.Major Areas inspected:10CFR21 & Procurement Program IR 05000482/19880071988-05-0505 May 1988 Insp Rept 50-482/88-07 on 880215-0331.Violation Noted.Major Areas Inspected:Followup of Previously Identified NRC Items, Operational Safety Verification,Esf Sys Walkdown,Monthly Maint & Surveillance Observations & Physical Security ML20151N9321988-04-11011 April 1988 Insp Rept 50-482/88-09 on 880314-18.Violation Noted.Major Areas Inspected:Solid Radwaste Program,Transportation Activities & Low Level Radwaste Storage Facilities ML20151V0511988-04-11011 April 1988 Insp Rept 50-482/88-12 on 880307-11.No Violation Noted.Major Areas Inspected:Emergency Plan Implementing Procedures, Emergency Facilities,Equipment,Instrumentation & Supplies, Training & Independent Reviews/Audits ML20148Q9141988-04-0505 April 1988 Insp Rept 50-482/87-24 on 871019-23.Violations Noted.Major Areas Inspected:Implementation of Equipment Qualification Commitments Identified in SER (NUREG-0881) & Suppls 4 & 5 IR 05000482/19880111988-03-15015 March 1988 Insp Rept 50-482/88-11 on 880222-26.Violation Noted.Major Areas Inspected:Inservice Testing of Pumps & Valves,Program & Organization,Procedure & Records,Test Witness & Personnel Qualification & Training IR 05000482/19880011988-03-0909 March 1988 Insp Rept 50-482/88-01 on 880104-0214.Violations Noted.Major Areas Inspected:Onsite Event Followup,Esf Sys Walkdown,Part 21 Followup,Physical Security Verification & Radiological Protection ML20147C9711988-02-23023 February 1988 Insp Rept 50-482/87-33 on 871119-880103.Violations Noted. Major Areas Inspected:Plant Startup from Refueling, Operational Safety Verification,Monthly Maint Observation, Monthly Surveillance Observation & Cathodic Protection Sys IR 05000482/19870331988-02-23023 February 1988 Insp Rept 50-482/87-33 on 871119-880103.Violations Noted. Major Areas Inspected:Plant Startup from Refueling, Operational Safety Verification,Monthly Maint Observation, Monthly Surveillance Observation & Cathodic Protection Sys 1990-09-28
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARIR 05000482/19990091999-10-0707 October 1999 Insp Rept 50-482/99-09 on 990830-0903.No Violations Noted. Major Areas Inspected:Events,Emergency Preparedness Facilities & Equipment,Emergency Plan & Implementing Procedures & Emergency Response Organization Training IR 05000482/19990051999-09-21021 September 1999 Insp Rept 50-482/99-05 Has Been Rescheduled for Next Yr.Insp Rept Will Not Be Issued IR 05000482/19990131999-09-20020 September 1999 Insp Rept 50-482/99-13 on 990725-0904.Noncited Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19990121999-09-14014 September 1999 Insp Rept 50-482/99-12 on 990816-20.No Violations Noted. Major Areas Inspected:Solid Radioactive Waste Mgt Program, Radioactive Matls Transportation Program,Facilities & Equipment,Staff Kowledge & Performance & Staff Training IR 05000482/19990161999-08-26026 August 1999 Insp Rept 50-482/99-16 on 990809-13.No Violations Noted. Major Areas Inspected:Planning & Preparation,Program to Maintain Occupational Exposure Alara,Temporary Shielding Program & Hot Spot Reduction Program IR 05000482/19990081999-08-18018 August 1999 Insp Rept 50-482/99-08 on 990613-0724.Noncited Violation Identified.Major Areas Inspected:Operations,Maint & Plant Support IR 05000482/19993011999-08-17017 August 1999 Exam Rept 50-482/99-301 on 990726-29.Exam Results:All Nine Applicants Passed Written Exams & Exhibited No Broad Knowledge or Training Weaknesses IR 05000482/19990111999-08-13013 August 1999 Insp Rept 50-482/99-11 on 990712-16.No Violations Noted. Major Areas Inspected:Review of Radiological Environ Monitoring Program,Meterological Monitoring Prgram & Results of Licensee Investigation of 990525 Personnel Event IR 05000482/19990151999-08-10010 August 1999 Canceled Insp Rept 50-482/99-15.No Inspection Rept Will Be Issued for This Rept Number IR 05000482/19990071999-07-15015 July 1999 Insp Rept 50-482/99-07 on 990614-18.No Violations Noted. Major Areas Inspected:Routine Insp Reviewed Radiation Protection Program Activities IR 05000482/19990061999-07-0202 July 1999 Insp Rept 50-482/99-06 on 990502-0612.Two Violations Occurred & Being Treated as Noncited Violations.Major Areas Inspected:Operations,Maint,Engineering & Plant Support PNO-IV-99-029, on 990625,female Licensee Employee Was Discovered Contaminated in Facial Area.Licensee Convened Incident Investigation Team to Assess Event.Worker Received Total Effective Dose Equivalent of Approx 7 Mrem1999-06-28028 June 1999 PNO-IV-99-029:on 990625,female Licensee Employee Was Discovered Contaminated in Facial Area.Licensee Convened Incident Investigation Team to Assess Event.Worker Received Total Effective Dose Equivalent of Approx 7 Mrem IR 05000482/19990031999-05-21021 May 1999 Insp Rept 50-482/99-03 on 990321-0501.Four NCVs Noted.Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000482/19990041999-05-0505 May 1999 Insp Rept 50-482/99-04 on 990405-09.No Violations Noted. Major Areas Inspected:Licensee Implementation of Facility Inservice Insp Program & Followup Review of Previously Identified Insp Findings IR 05000482/19990021999-04-0909 April 1999 Insp Rept 50-482/99-02 on 990207-0320.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19990011999-01-26026 January 1999 Insp Rept 50-482/99-01 on 990111-14.No Violations Noted. Major Areas Inspected:Testing & Maintenance,Protected Area Barriers & Detection Aids,Vital Area Barriers & Detection Aids,Compensatory Measures & Security Sys Power Supply IR 05000482/19980201999-01-15015 January 1999 Insp Rept 50-482/98-20 on 981115-1226.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000482/19980161998-12-10010 December 1998 Informs That Insp Rept 50-482/98-16 Was Combined with Insp Rept 50-482/98-12,therefore,no Rept Will Be Issued for Rept 50-482/98-16 ML20196H3711998-12-0303 December 1998 Insp Rept 50-482/98-19 on 981002-1114.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support.Licensee Response to Road Closure Due to Flooding within 10-mile Emergency Zone Was Excellent PNO-IV-98-051, on 981102,flooding in Vicinity of Wolf Creek Generating Station Occurred.Licensee Has Been in Close Contact with Army Corps of Engineers,Region VII Ofc of Federal Emergency Mgt Agency Emergency Organizations1998-11-0505 November 1998 PNO-IV-98-051:on 981102,flooding in Vicinity of Wolf Creek Generating Station Occurred.Licensee Has Been in Close Contact with Army Corps of Engineers,Region VII Ofc of Federal Emergency Mgt Agency Emergency Organizations ML20155A1871998-10-22022 October 1998 Insp Rept 50-482/98-17 on 980823-1003.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support.Use of Fire Protection Sys Pumps for Purposes Other than Fire Protection Constituted Degradation of Sys IR 05000482/19980181998-10-0505 October 1998 Insp Rept 50-482/98-18 on 980921-25.No Violations Noted. Major Areas Inspected:Licensee Physical Security Program Including Access Authorization,Alarm Stations,Assessment Aids,Communications & Security Program Plan & Procedures ML20154C7031998-09-29029 September 1998 Notice of Violations from Insp on 980323-0410 & 0622-25. Violations Noted:Without Prior Commission Approval & Without Performing Written Safety Evaluations,Licensee Made Changes Described in USAR Re Unreviewed Safety Question ML20154C7071998-09-29029 September 1998 Insp Rept 50-482/98-12 on 980323-0410 & 0622-25.Violations Noted.Major Areas Inspected:Engineering & Plant Support IR 05000482/19980151998-09-0404 September 1998 Insp Rept 50-482/98-15 on 980712-0822.No Violations Noted. Major Areas Inspected:Operation,Maint,Engineering & Plant Support ML20236T1461998-07-23023 July 1998 Insp Rept 50-482/98-14 on 980531-0711.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20236T1431998-07-23023 July 1998 Notice of Violation from Insp on 980531-0711.Violation Noted:On 980604,technicians Placed Heavy Door & Frame in Control Room Equipment Cabinet Adjacent to Train a Protection Sys Logic Cabinets IR 05000482/19980131998-06-12012 June 1998 Insp Rept 50-482/98-13 on 980419-0530.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20249A0341998-06-12012 June 1998 Notice of Violation from Insp on 980419-0530.Violation Noted:On 980317,electricians Removed Breaker NG001AGF1 While Clearance Order 98-0250-EF Relied on Procedure Mge EOOP-11 to Establish Isolation of Breaker from Bus ML20248B6471998-05-27027 May 1998 Notice of Violation from NRC Investigation on 961224-980206. Violation Noted:On 961211,S Buehne Intentionally Submitted Info to Licensee Known to Be Inaccurate & Info Submitted to NRC ML20247Q3461998-05-22022 May 1998 SALP Rept 50-482/98-99 for Period 970406-980418 ML20216A8881998-05-0606 May 1998 Notice of Violation from Insp on 980308-0418.Violation Noted:On 980410,an Accessible High Radiation Area on Radwaste Bldg Roof W/Dose Rate of Approx 400 Mr/H at 18 Inch Was Not Posted as High Radiation Area ML20216A9051998-05-0606 May 1998 Insp Rept 50-482/98-10 on 980308-0418.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20217M3691998-04-30030 April 1998 Insp Rept 50-482/98-07 on 980330-0403.No Violations Noted. Major Areas Inspected:Operational Status of Licensee Emergency Preparedness Program ML20217E0851998-04-23023 April 1998 Notice of Violation from Insp on 970624-27.Violation Noted: Licensee Identified That Unauthorized Work, (Work Outside Scope of Assigned Work Package Tasks & Applicable Procedures) Performed & Not Documented ML20217M5291998-04-0202 April 1998 Notice of Violation from Insp on 980316-20.Violation Noted: Inspector Identified Seven Radioactive Matl Containers Located in Radwaste Storage Bldg ML20217M5491998-04-0202 April 1998 Insp Rept 50-482/98-11 on 980316-20.Violations Noted.Major Areas Inspected:Implementation of Solid Radwaste Mgt & Radioactive Waste/Matls Transportation Programs IR 05000482/19980041998-04-0101 April 1998 Insp Rept 50-482/98-04 on 980125-0307.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20217H6431998-04-0101 April 1998 Notice of Violation from Insp on 980125-0307.Violation Noted:Operators Failed to Log Entry Into Action Statement for TS 3.1.3.5 Shutdown Rods Inserted Beyond Rod Insertion Limits IR 05000482/19980081998-03-30030 March 1998 Insp Rept 50-482/98-08 on 980302-06.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support ML20216G5661998-03-13013 March 1998 Notice of Violation from Insp on 980223-27.Violation Noted: Proper Surveys Were Not Performed to Prevent Unconditional Release of Radioactive Matls Greater than Release Criteria ML20216G5761998-03-13013 March 1998 Insp Rept 50-482/98-09 on 980223-27.Violation Noted.Major Areas Inspected:Radiation Protection Program IR 05000482/19980021998-03-0606 March 1998 Insp Rept 50-482/98-02 on 980202-06.No Violations Noted. Major Areas Inspected:Maint,Engineering & Emergency Preparedness IR 05000482/19980061998-02-27027 February 1998 Insp Rept 50-482/98-06 on 980202-06.No Violations Noted. Major Areas Inspected:Review of Radiation Protection Program Activities ML20203K9181998-02-26026 February 1998 Insp Rept 50-482/98-03 on 980202-06.No Violations Noted. Major Areas Inspected:Implementation of Liquid & Gaseous Radwaste Mgt Program,Training & Qualifications,Qa Oversight, Facilities & Equipment & Annual Repts ML20203K2831998-02-26026 February 1998 Insp Rept 50-482/98-301 on 980217.No Violations Noted.Major Areas Inspected:Operations,Including Evaluation of Competency of 2 Retake RO & 2 SRO Retake License Applicants for Issuance of Operating Licenses at Facility ML20203H5341998-02-23023 February 1998 Insp Rept 50-482/97-201 on 971103-980109.No Violations Noted.Major Areas Inspected:Capability of RHR & CCW Sys to Perform Safety Functions Required by Design Bases & Adherence of Sys to Design & Licensing Bases IR 05000482/19970211998-02-0909 February 1998 Insp Rept 50-482/97-21 Cancelled ML20199H9141998-01-29029 January 1998 Notice of Violation from Insp on 971214-980124.Violation Noted:Technicians Failed to Follow Procedure Steps by Removing Vendor Wire & Reversed Variable Transformer Leads IR 05000482/19970231998-01-29029 January 1998 Insp Rept 50-482/97-23 on 971214-980124.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support 1999-09-21
[Table view] |
See also: IR 05000482/1986016
Text
.
9
APPENDIX B
US NUCLEAR REGULATORY COMMISSION
REGION IV
NRC Inspection Report: 50-482/86-16 LP: NPF-42
Docket: 50-482
Licensce: Kansas Gas and Electric Company (KG&E)
Post Office Box 208
Wichita, Kansas 67201
Facility Name: Wolf Creek Generating Station (WCGS)
Inspection At: Wolf Creek Site, Coffey County, Burlington, Kansas
Inspection Conducted: June 1 to July 5, 1986
Inspectors: ,
J. E. Cummins, Senior Resident Inspector,
7////BI
Date
l Operations, (pars. 2, 3, 4, 5, 6, 7, and 8)
oW A M//!7
~ B. L. Bartlett, Resident Reactor Inspector, ' Dd te
Operations, (pars. 2, 3, 4, 5, 6, 7, and 8)
,
bN nY
D. M. Hunnicutt, Chief, Operations Section 7 Dat(
9/8$>
i
Reactor Safety Branch (pars. 9 and 10)
G. A. P ck,
A%
sactor Inspector
Ld D!U
'Dath
b
(pars. 9 1 10)
I
Approved: I
tM
D. R. ifunter, Chief, Project Section B, Date
Reactor Projects Branch 2
i
!
!
l
8607310247 860725 2
PDR ADOCK 0500
'
G
l
.
1
-g-
Inspection Summary
Inspection Conducted June 1 to July 5, 1986 (Report 50-482/86-16)
Areas Inspected: Routine, unannounced inspection including plant status;
followup on previously identified NRC items; operational safety verification;
engineered safety features system walkdown; onsite followup of events; monthly
surveillance observation; monthly maintenance observation; plant safety review
' committee; and nuclear safety review committee.
Results: Within the nine areas inspected, one violation was identified
(failure to adequately isolate safety-related equipment prior to maintenance,
paragraph 8).
- . . . - . _ -. . ._
.
.
5
-3-
DETAILS
, 1. Persons Contacted
Principal Licensee Personnel
j *G. L. Koester, Vice President-Nuclear
! *J. A. Bailey, Interim Site Director
F. T. Rhodes, Plant Manager
- G. D. Boyer, Deputy Plant Manager
- M. Estes, Superintendent of Operations
- M. D. Rich, Superintendent of Maintenance
- M. G. Williams, Superintendent of Regulatory, Quality, and
1 Administrative Services
0. L. Maynard, Manager Licensing
i. *G. Pendergrass, Licensing
i *W. M. Lindsay, Supervisor Quality Systems
l
- C. J. Hoch, QA Technologist
- W. J. Rudolph, QA Manager-WCGS
! *A. A. Freitag, Manager Nuclear Plant Engineering-WCGS
M. Megehee, Compliance Engineer
. *R. Smith, Nuclear Information Supervisor
- D. Walsh, Maintenance Services Supervisor
,
- B. McKinney, Superintendent of Technical Support
,
The NRC inspectors also contacted other members of the licensee's staff
during the inspection period to discuss identified issues.
'
- Denotes those personnel in attendance at the exit meeting held on
July 8, 1986.
2. Plant Status
The plant operated in Mode 1 during this inspection period except during
the time periods described below:
o June 4 to 11, 1986 - Plant in Mode 3 (hot standby) for investigation
,
and maintenance related to limitorque electrical termination lugs.
o On June 30, 1986, the reactor tripped from 100 percent power because
of 10-10 steam generator water level. During the subsequent startup
on July 1,1986, the reactor tripp d at approximately 20 percent
4
power because of another 10-10 Steam Generator Level. The plant
}
was returned to Mode 1 on July 1, 1986,
i 3. Followup on Previoutl y Identified NRC Items
i
(Closed) Violation (482/8601-01): Failure To Comply With Licensee's
i Temporary Modification Procedure
J
_ . _ _ . _ _ _ _ _ _ . _ . _ . . _ , _ _ _ _ _ _ _ , _ _ _ _ _ _ _ _ _ _ _ , _ _ - . _ , _ . _ _ _ _ _ . - _ _ , _ _
.
'
.
-4-
The licensee discussed the temporary modification requirements with plant
supervisory personnel and issued a Quality Systems Engineering
Directive (86-01) alerting cognizant personnel to the possible need for
adding instructions to work request quality control inspection
instructions for restoration of work areas. The NRC inspectors have not
identified any additional occurrences of this type during subsequent plant
tours. This violation is closed.
(Closed) Violation (482/8604-01): Failure To Comply With Surveillance
Procedure Instructions
The NRC inspector reviewed Surveillance Test Procedure STS SF-001,
Revision 4, " Control and Shutdown Rod Operability Verification," and
verified that Section 2.2 had been changed to relax the precaution from no
change in reactor coolant system (RCS) baron concentration during
perfonaance of the test, to minimizing changes in RCS boron concentration
during the performance of the test. The NRC inspector verified by review
of required reading logs that operations personnel had initialed that they
had read Wolf Creek Event Report 86-17, which discussed this event and the
necessity for observing " precautions and limitations" during procedure
performance. This violation is closed.
(Closed) Violation (482/8604-02): Failure to Maintain Control Room
HVAC in Required State of Operability
The NRC inspector verified that signs requiring control room notification
prior to operating had been installed adjacent to the control room HVAC
control switches. The NRC inspector verified by review of required
reading logs that operations personnel had initialed that they had read
Licensee Event Report 86-006-00, which discussed this event. This
violation is closed.
(Closed) Violation (482/8604-03): Fireproofing Removed From Support Beam
The NRC inspector verified that a knowledgeable individual has been
assigned the responsibility of overseeing the removal and replacement of
fireproofing material, and verified by random sampling that no other
violations of this type have been identified. This violation is closed.
(Closed) Violation (482/8604-04): Out-of-Date Procedures
The NRC inspector performed surveillances of randomly selected alarm
response procedures located at remote alarm panels and no out-of-date
procedures were identified. This violation is closed.
4. Operational Safety Verification
The NRC inspectors verified that the facility is being operated safely and
in conformance with regulatory requirements by direct observation of
licensee facilities, tours of the facility, interviews and discussions
with licensee personnel, independent verification of safety system status
.
.
-5-
and limiting conditions for operations, and by reviewing facility records.
The NRC inspectors, by observation, interview of personnel, and review of
documents, verified the physical security plan was being
implemented in accordance with the security plan and that radiation
protection activities were controlled.
By observing valve position, electrical breaker position, and control room
indication, the NRC inspectors confirmed the operability of the Safety
Injection System, the Coolant Charging System, and the 4160 Volt AC Class
1E. System. The NRC inspectors also visually inspected safety components
for leakage, physical damage, and other impairments that could prevent
them from performing their designed function.
No violations or deviations were identified.
5. Engineered Safety Features (ESF) System Walkdown
"The NRC inspectors verified the operability of ESF systems by walking down
selected accessible portions of the systems. The NRC inspectors verified
valves and electrical circuit breakers were in the required position,
power was available, and valves were locked where required. The NRC
inspectors also inspected system components for damage or other conditions
that could degrade system performance.
The ESF systems walked down during this inspection period and the
documents utilized by the NRC inspectors during the walkdown are listed
below:
System Documents
Auxiliary Feedwater System (AL) Drawing M-12AL01, Revision 0,
Auxiliary Feedwater System P&ID(Q),
Drawing M-12FC02, Revision 1, Auxiliary
Feedwater Pump Turbine P&ID(Q),
Checklist CKL AL-120, Revision 7,
Auxiliary Feedwater Normal Lineup,
Surveillance Tests, STS IC-706,
Revision 1, " Steam Generator N/R Level
Transmitter Response Time
Test-Protection Set I,"
STS IC-260, Revision 3, " Analog Channel
Operational Test Auxiliary Feedwater
Pump Suction Pressure Low Transfer To
ESW,"
.
.
.
-6-
'
STS IC-560, Revision 2, " Channel
Calibration-Auxiliary Feedwater Pump
Low Suction Pressure (Transfer To ESW)"
STS IC-505B, Revision 1, " Channel
Calibration Steam Generator Narrow
Range Level,"
STS IC-505A, Revision 1, " Calibration
Of Steam Generator Narrow-Range Level
Transmitters,"
Class 1E 125 V DC System (NK) Drawing E-01 NK01(Q), Revision 15,
" Class 1E 125 V DC System Meter &
Relay Diagram"
Drawing E-01 NK02(Q) Revision 17,
" Class 1E 125 V DC System Meter &
Relay System"
Checklist CKL NK-131, Revision 1, "NK
Distribution Switchboard Switch
Lineup Checklist"
Class 1E 120 V AC System (NN) Drawing E-03 NN01(Q), Revision 12,
" Class 1E Instrument AC Schematic"
Checklist CKL NN-131, Revision 4,
" Instrument AC Power (Class 1E)
Switchboard Breaker Checklist"
Selected NRC inspector observations are discussed below:
a. The following discrepancies related to Checklist CKL NK-131, Revision
1, "NK Distribution Switchboard Switch Lineup Checklist" were
identified:
o On page 2 of 9 Switch NK 4103 was incorrectly described as an
active circuit; however, it was a spare as identified on
Switchboard NK41 and in note 6 of Drawing E-ul NK02,
Revision 17, " Class 1E 125 V DC System Meter and Relay Diagram."
o On page 8 of 9 Switches NK5402 and NK5408 were incorrectly
described as active circuits; however, they were spares as
identified on Switchboard NK54 and in note 9 of
Drawing E-01 NK02, Revision 17, " Class 1E 125 V DC System Meter
and Relay Diagram."
o On page 7 of 9 the description of Switch NK4410 was incorrect.
It should have read "MCB CONT PNL RLO25 and RLO26," rather than
"MCB CONT PNL RLO25 and RLO24."
_
=. . . - . - -.
.
.
-7-
o On page 2 of 9 the description of Switch NK4112 was incorrect.
It should have read "MCB CONT PNL RL017 and RL018" rather than
"MCB CONT PNL RL017 and RL013."
! o The information plate for Switch NK4408 on Switchboard NK44
should have read " Fused DC Dist PNL RP316," rather than " Fused
l
DC Dist PNL RP3116."
b. The following discrepancies related to Checklist CKL NN-131, Revision
4, " Instrument AC Power (Class 1E) Switchboard Breaker Checklist were
<
identified."
o On Switchboard NN01 the label plate for Switch No.11 was
labeled " Panel SB03B," it should be labeled " Panel SB038" as
shown on Drawing E-03 NN01(Q), Revision 12 " Class 1E Instrument
AC Schematic."
o On page 4 of 7 procedure identified Switch 13 on
Switchboard NN02 as " Panel SB054B," it should be " Panel SE054B"
- as shown on Drawing E-03 NN01(Q), Revision 12, " Class 1E
Instrument AC Schematic."
o Switch 6 on Switchboard NN04 was being used to feed the " Neutron
Flux Monitoring Signal Amplifier SENY61A;" however, it was not
listed in Procedure CKL NN-131. Drawing E-03 NN01(Q),
i Revision 12, " Class 1E Instrument AC Schematic" shows that the
! switch was put in use by Design Change Package DCP-CS-63.
o Switch 8 on Switchboard NN04 was being used to feed " Neutron
Flux Monitor Processor SENY61B;" however, it was not listed in
Procedure CKL NN-131. Drawing E-03 NN01(Q), Revision 12, " Class
IE Instrument AC Schematic" showed that the switch was put in
use by Design Change Package DCP-CS-63.
The deficiencies described in a. and b. above will be an unresolved
- item (482/8616-02) pending further review by the NRC inspector during
j a subsequent inspection to determine the reason for the deficiencies
and if corrective action is required.
No violations or deviations were identified.
6. Onsite Followup of Events
a. events
The NRC inspector
that occurred duringperformed
this report onsite
period.followup
The NRCof inspector
non-emergency (when
available) observed control room personnel response, observed
instrumentation indicators of reactor plant parameters, reviewed logs
and computer printouts, and discussed the event with cognizant
personnel. The NRC inspector verified the licensee had responded to
the event in accordance with procedures and had notified the NRC and
other agencies as required in a timely fashion.
.
.
-8-
Engineered safety feature actuations that occurred during the report
period are listed in the table below. Where applicable, the NRC
inspector will review the LER for each of these events and will
report any findings in subsequent NRC inspection reports.
Date Event * Plant Status Cause
6-4-86 FWIA Mode 2 being High Water Level
shut down SG C
6-18-86 ESF Components Mode 1 **ESF Circuit Wire
Actuated (100%) Shorted During
Maintenance On Limi-
torque Valve EN HV-15
6-26-86 ESF Actuation Mode 1 Loss Of Power To ESF
(100%) Buss NB01 Due To Dis-
connect Opening in
Switchyard
6-30-86 Rx Trip Mode 1 Lo-Lo SG Water
(100%) Level-Condensate
Pumps Tripped Off
7-1-86 Rx Trip Mode 1 Lo-Lo SG Water
(100%) Level
7-2-86 CRVIS Mode 1 Loss Of Control Room
(100%) Radiation Monitors
CRVIS - control room ventilation isolation signal
FWIA - feedwater isolation actuation
Rx Trip - reactor trip
- See paragraph 8 for details
Selected NRC inspector observations are discussed below:
o The ESF actuation on June 26, 1986, was caused by a loss of
power to ESF 4160 V AC electrical buss, NB01, due to a
disconnect in the switchyard opening. The emergency diesel
generator automatically started and picked up safety loads that
sequenced onto the bus per design. The disconnect in the
switchyard was reclosed and the affected electrical system
returned to a normal line up,
o The reactor trip that occurred on June 30, 1986, was due to a
10-10 steam generator water level. The 10-10 steam generator
water level condition was the result of all three condensate
pumps tripping off due to maintenance work being performed on
the condenser water level instrumentation.
.
.
-9-
o The reactor trip that occurred on July 1, 1986, was due to a
10-10 steam generator water level condition. The event occurred
-
.during plant startup at approximately 20 percent power, while
plant personnel were transferring steam generator feedwater flow
from the main feedwater regulator bypass valves to the main
feedwater regulator valves. The subsequent startup was
accomplished with no significant problems.
b. During this report period, the NRC inspectors reviewed licensee event
- reports and defect / deficiency reports (DDR).
A DDR is an internal licensee report on defects and/or deficiencies
found in design or construction. These reports are issued to
appropriate personnel and agencies.
Wolf Creek event reports are internal documentation of events that
are not specifically reportable as a defect / deficiency report, but
are events which plant management should be made aware of.
Wolf Creek event reports reviewed this report period:
No. Title
86-039 " Improper Safety Class Marked on Work Request (WR)"86-047 " Overfilling the HF Evaporator"86-050 "No Flow At S/G Blowdown Effluent Radiation Monitor"
Defect / deficiency reports reviewed this report period:
No. Title
85-100 " Jacket Water Heaters For Standby Diesel Generators
Each Had One Cable Burnt. . . ."86-038 "GH RE-10A Automatically Isolates During Testing Of
"
GH RE-108 and Does Not Automatically Reset. ...86-046 ". . . Valve EF HV-97 Was Found Shut With Valve
Power Removed."86-052 ". . . Impairment 86-075 Was Not Checked By the
Responsible Officer. . . ."
The NRC inspector had the following comments:
o DDR 86-038 stated "On May 15, 1986, based on a conversation with
Callaway personnel, it was discovered that GH RE-10A
automatically isolates during testing of GH RE-108 and does not
automatically reset upon completion of GH RE-10B testing.
GH RE-10A is receiving flow from the building atmosphere while
it is isolated and therefore, no RM-11 indication of a problem
r.
.
.
-10-
exists,-although, a local alarm is present." GH RE-10A was the
radwaste building vent particulate and iodine radiation monitor
and GH RE-10B was the radwaste building vent noble gas monitor.
,
This condition could result in venting of a waste gas decay tank
with GH RE-10A out-of-service. The licensee subsequently
received and_ reviewed Callaway Plant LER 50-483/86-011-00 for
applicability ;to Wolf Creek Generating Station. The licensee's
review of this LER showed that instrumentation and control (I&C)
calibration procedures ensured that GH RE-10A was properly
restored to service after testing of GH RE-10B was completed and
a review of the past releases did not find any instances of GH
RE-10A being found isolated. A temporary procedure change was
made to ensure personnel understood the need to reset GH RE-10A
after testing of GH RE-10B and an information tag was hung in
the control room to ensure operators were aware of this
situation. In response to NRC inspector concerns on this
subject, the licensee has submitted an engineering evaluation
request (EER) to nuclear plant engineering (NPE) to see if
adding a separate annunciator in the control room for GH RE-10A
or adding an automatic reset to GH RE-10A would be desirable.
The completion of the EER and any related modifications was not
required by regulations and thus will not be tracked as an
inspector followup item or a commitment.
No violations or deviations were identified.
7. Monthly Surveillance Observation
The NRC inspectors observed selected portions of the performance of
surveillance testing and/or reviewed completed surveillance test
procedures to verify that surveillance activities were performed in
accordance with TS requirements and administrative procedures. The NRC
inspectors considered the following elements while inspecting surveillance
activities:
s o Testing was being accomplished by qualified personnel in accordance-
with an approved procedure.
o The surveillance procedure conformed to TS requirements.
o Required test instrumentation was calibrated.
o Technical Specification limiting conditions for operation (LCO) were
satisfied.
o Test data was accurate and complete. Where appropriate, the NRC
inspectors performed independent calculations of selected test data
to verify their accuracy.
o The performance of the surveillance procedure conformed to applicable
administrative procedures.
o The surveillance was performed within the required frequency and the
test results met the required limits.
f l
.
.
-11-
Surveillances witnessed and/or reviewed by the NRC inspectors are listed
below:
o STS RE-002, Revision 3, " Determination Of Estimated Critical
Position" performed June 11, 1986
o STS RE-002, Revision 3, " Determination Of Estimated Critical
Position" performed July 1, 1986
o STS RE-004, Revision 4, " Shutdown Margin Determination" performed
July 1, 1986
o STS PE-013, Revision 5, " Personnel Air'ock Seal Test," performed
June 18, 1986
o STS AL-102, Revision 3, " Motor Driven Aux FW Pump iB' Inservice
Pump Test," performed June 18, 1986
o STS RE-012, Revision 1, " Quadrant Power Tilt Ratio," performed
June 18, 1986
Selected NRC inspector observations are discussed below:
On June 11, 1986, the licensee notified the NRC inspectors that a
violation of TS Surveillance 4.6.3.1 had occurred in that this TS requires
that a post maintenance cycling test be performed on any containment
isolation valve listed in TS Table 3.6.1. Maintenance was performed on
the valves listed below, and the licensee determined a continuity test was
to be performed to verify operability prior to returning the valves to
operable status. The licensee subsequently identified the TS oversight
and performed cycling tests on the valves. The table below notes the
dates when r.aintenance was completed on each valve and when the cycling
test was performed. All the valves passed the subsequent cycling test.
Valve Date/ Time Date/ Time
No. Description Work Completed Stroke Tested
LF FV 095 RW Bldg. Demin Vault Floor
Dr. Lower Iso. 6-05-86/2358 6-09-86/2050
GS HV 020 Hydrogen Purge Inner
Containment Iso. 6-06-86/0430 6-06-86/0430
GS HV 021 Hydrogen Purge Outer
Containment Iso. 6-12-86/0810 6-12-86/1038
KC HV 253 Turb. Bldg. Hose Station Iso.
Elevatf ori 2051' 6-08-86/0813 6-08-86/1700
EG HV 058 CCW to RCS Iso. 6-07-86/2200 6-09-86/2142
EG HV 059 CCW Return From RCS Iso. 6-07-86/2200 6-09-86/2142
EG HV 060 CCW Return From RCS Iso. 6-07-86/1600 6-09-86/2050
EG HV 061 CCW Return From RCS Iso. 6-07-86/2322 6-08-86/0215
EG HV 062 CCW Return From RCS Iso. 6-07-86/2115 6-09-86/2050
EG HV 127 CCW To RCS HV-58 & HV-71
'
.
l
>
-12-
Bypass Iso. 6-08-86/0455 6-09-86/2142
EG HV 130 RCS CCW Return HV-60
Bypass Iso. 6-06-86/2150 6-09-86/2050
EG HV 131 RCS CCW Return HV-59
Bypass Iso. 6-09-86/2103 6-09-86/2142
EG HV 132 . Thermal Barrier CCW Return
HV-62 Bypass Iso. 6-06-86/2150 6-09-86/2050
EG HV 133 Thermal Barrier CCW Return
HV-61 Bypass Iso. 6-08-86/1300 6-08-86/1325
EF HV 031 ESW A to CTMT Air Coolers 6-17-86/1100 6-17-86/1125
EF HV 032 ESW B to CTMT Air Coolers 6-13-86/2513 6-13-86/2315
EF HV 033 ESW A to CTMT Air Coolers 6-05-86/0236 6-05-86/1729
EF HV 034 ESW B to CTMT Air Coolers 6-07-86/1840 6-07-86/1945
EF HV 045 ESW A From CTMT Air Coolers 6-07-86/0445 6-07-86/0445
EF HV 046 ESW B From CTMT Air Coolers 6-07-86/1840 6-07-86/2040
EF HV 047 ESW A From CTMT Air Coolers
Bypass 6-13-86/0650 6-13-86/0650
EF HV 048 ESW A From CTMT Air Coolers
Bypass 6-13-86/2200 6-13-86/2222
EF HV 049 ESW A From CTMT Air Coolers 6-16-86/1700 6-16-86/1733
EF HV 050 ESW B From CTMT Air Coolers 6-13-86/2300 6-13-86/2306
EN HV 006 CTMT Spray Train A Disch.
Iso. Valve 6-09-86/0514 6-09-86/2050
EN HV 012 CTMT Spray Train B Disch.
Iso. Valve 6-08-86/1510 6-09-86/2050
EM HV 8801A BIT Outlet Iso. 6-08-86/0238 6-09-86/2050
EM HV 8801B BIT Outlet Iso. 6-08-86/0545 6-09-86/2050
BG HV 8100 Seal Water Return CTMT
Iso. Valve 6-09-86/1900 6-10-86/2045
BG HV 8112 Seal Water Return CTMT
Iso. Valve 6-06-86/0738 6-19-86/2045
BG HV 8105 Charging Pumps to Regen.
HV/CTMT Iso. 6-06-86/2155 6-10-86/0457
BB HV 8351A RCP A Seal Water Supply 6-08-86/1708 6-10-86/0012
BB HV 8351B RCP B Seal Water Supply 6-08-86/1750 6-10-86/0012
BB HV 8351C RCP C Seal Water Supply 6-08-86/1732 6-10-86/0012
BB HV 83510 RCP D Seal Water Supply 6-08-86/1850 6-10-86/0012
BB PV 8702A RCS Hot Leg 1 to RHR
Pump A Suction 6-07-86/1500 6-11-86/0141
BB PV 8702B RCS Hot Leg 4 to RHR
Pump B Suction 6-07-86/1500 6-11-86/0213
EJ HB 8701A RCS Hot Leg 1 to RHR
Pump A Suction 6-05-86/1725 6-11-86/0141
EJ HV B701B RCS Hot Leg 4 to RHR
Pump B Suction 6-06-86/1500 6-11-86/0213
EJ HB 8809A RHR to ACCUM Inj.
Loop 1 & 2 Iso. Valve 6-06-86/2055 6-09-86/2215
EJ HV 8809B RHR to ACCUM Inj
.
'
,
-13-
Loops 3 & 4 Iso. Valve 6-09-86/0904 6-09-86/2215
EJ HB 8840 RHR/SI Hot Leg Recirc
Iso. Valve 6-08-86/2312 6-09-86/2215
EM HV 8802A SI Pump A Discharge Hot Leg
Iso. Valve 6-08-86/0049 6-09-86/2115
EM HV 8802B SI Pump B Discharge Hot Leg
Iso. Valve 6-09-86/1219 6-09-86/2115
EM HV 8835 Safety Inj Cold Leg
Iso. Valve 6-09-86/1052 6-09-86/2115
We have no further questions of this matter at this time. Further review
of this matter will be performed during the subsequent review of the
licensee corrective action report and the event report.
No violations or deviations were identified.
8. Monthly Maintenance Observation
The NRC inspector observed maintenance activities performed on
safety-related systems and components to verify that these activities were
conducted in accordance with approved procedures, Technical
Specifications, and applicable industry codes and standards. The
following elements were considered by the NRC inspector during the
observation and/or review of the maintenance activities:
o LCOs were met and, where applicable, redundant components were
operable,
o Activities complied with adequate administrative controls.
o Where required, adequate, approved, and up-to-date procedures were
used.
o Craftsmen were qualified to accomplish the designated task and
technical expertise (i.e., engineering, health physics, operations)
was made available when appropriate.
o Replacement parts and materials being used were properly certified.
o Required radiological controls were implemented.
o Fire prevention controls were implemented where appropriate.
o Required alignments and surveillances to verify post maintenance
operability were performed.
o Quality control hold points and/or checklists were used when
appropriate and quality control personnel observed designated work
activities.
, Selected portions of the maintenance activities accomplished on the WR
listed below were observed and related documentation reviewed by the NRC
inspector:
No. Title
i WR 02601-86 " Rework Limitorque Operator To Valve EM HV-8814B"
!
WR 02737-86 "EJ FCV-0611 Actuator"
i
i
- _ _ _ _ _ _ _ - - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ __ ___ _ _ _ _ _ _ _ _ _ - _ .
,.
-14-
,
t
Rework Limitorque Operator To Valve AL HV-009"
WR 02513-86
WR 02514-85 "
Rework Limitorque Operator To Valve AL HV-011"
"
WR 00192-86 DCGM01B Breakee Trips Frequently"
"
WR 02778-86 KJ HV-002"
"
WR 02777-86 EF PDV-20"
"
WR 02776-86 EF HV-98"
WR 02399-86 " Alternator NE02 Failed Oil Analysis"
WR 02544-86 "EF HV-025, Vendor Installed Lugs and Wire Quality
Are Indeterminate"
WR 07073-85 "EN HV-015, Maintenance On Limitorque Operator"
Selected NRC inspector observations are discussed below:
While performing maintenance on Limitorque Valve EN HV-015 in accordance
with WR 07073-85, the electrician shorted electrical wires to ground
causing the actuation of the following engineered safety features
components:
o LOCA sequencer actuated.
o Containment spray pump "A'" started,
o Essential service water / service water crossconnect valves closed.
The wires that were shorted were part of the solid state protection system
slave relay test circuit. The electrician was not aware that the leads
had not been de-energized. TS 6.8.1 requires that, " Written procedures
shall be established, implemented, and maintained covering . . . a. The
applicable procedures recommended in Appendix A of Regulatory Guide
(RG) 1.33, Revision 2, February 1978." Section 9.a of RG 1.33, Revision
2, February 1978, states that, ". . . maintenance that can affect the
performance of safety-related equipment should be properly preplanned and
performed in accordance with written procedures, docunented instructions, '
or drawings appropriate to the circumstances." This unanticipated
actuation of ESF components due to the failure to adequately preplan
(isolate) a maintenance activity as required by the above documents is an
apparent violation (482/8616-01).
9. Plant Safety Review Committee (PSRC) j
!
The NRC inspector reviewed Section 6.5.1 of the TS regarding the onsite
review committee, PSRC. This review determined that the PSRC met
regulatory guidelines and commitments.
,
-~ ~- ~-- n--, , , , _ _ _ _ ,,____ , _ _ , , _ _ _ _ _ _ , _ , _ _ , _
,.
-15-
The PSRC reviews and analyzes defect / deficiency reports to detemine
whether a licensee event report should be submitted and what course of
action should be initiated to correct TS violations.
The PSRC reviewed the safety evaluations related to design changes, major
procedure revisions, or plant tests / experiments that reflected a change to
the TS or a condition not analyzed in the Final Safety Analysis Report
(FSAR) that resulted from 10 CFR Part 50.59 reviews.
The PSRC reviewed current unit operations through their considerations for
approval of " Jump-up" items such as temporary change forms regarding shif t
logs, surveillances, tests, and so forth.
Plant procedure revisions were also reviewed by the PSRC.
No violations or deviations were identified.
10. Nuclear Safety Review Comittee (NSRC)
The NRC inspector reviewed Section 6.5.2 of the licensee's TS regarding
the offsite review comittee, NSRC. The NRC inspector determined that the
NSRC met their comitments to regulatory guidance, in the areas of
composition, duties, and responsibilities.
The NSRC audit subcomittee reviewed selected audits that related to the
requirements listed in the TS. The review consisted of examining
completed reports of audits that were conducted by the quality assurance
(QA) department. The audits were scheduled such that the essential
elements - those elements necessary to meet regulatory requirements -
were met and reviewed at the required frequency. The NSRC committee
remained cognizant of their required audit activities by assigning a
comittee member with overview responsibility. The audit subcomittee
reported to the full NSRC.
The NRC inspector reviewed the NSRC's meeting minutes from March 1985
through April 1986. From the review of the NSRC meeting minutes, the
inspector determined that the NSRC comittee retained proper cognizance
through detailed subcomittee reviews in the areas of plant modifications
and violations and reportable events. The NSRC also reviewed the onsite
review comittee minutes and any significant operatirg abnormalities or
system structure and/or component design deficiencies.
No violations or deviations were identified.
11. Exit Meeting
The NRC inspectors met with licensee personnel to discuss the scope and
findings of this inspection on July 8, 1986. The NRC inspectors also
attended entrance / exit meetings of other NRC region based inspectors
identified below:
c
,. .
-16-
Inspection Lead Area Inspection
Period Inspector Inspected Report No.
b'
6-2/5-86 -
J. Whittemore Operator Licensing
Exams OL 86-01
,
6-16/20-86 J. Boardman Maintenance 50-482/86-15
_
6-16/20-86 D. Hunnicutt Review Committee 50-482/86-16
, , (pars. 9 & 10)
During the week of. June 16 through 20, 1986, the NRC Project Manager for
, WCGS, P. O'Connor, visited the site and held discussions with licensee
personnel.
.
-l
'd
l
l
l
,
1