Insp Rept 50-482/99-12 on 990816-20.No Violations Noted. Major Areas Inspected:Solid Radioactive Waste Mgt Program, Radioactive Matls Transportation Program,Facilities & Equipment,Staff Kowledge & Performance & Staff TrainingML20216F171 |
Person / Time |
---|
Site: |
Wolf Creek |
---|
Issue date: |
09/14/1999 |
---|
From: |
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
---|
To: |
|
---|
Shared Package |
---|
ML20216F168 |
List: |
---|
References |
---|
50-482-99-12, NUDOCS 9909210179 |
Download: ML20216F171 (10) |
|
|
---|
Category:INSPECTION REPORT
MONTHYEARIR 05000482/19990091999-10-0707 October 1999 Insp Rept 50-482/99-09 on 990830-0903.No Violations Noted. Major Areas Inspected:Events,Emergency Preparedness Facilities & Equipment,Emergency Plan & Implementing Procedures & Emergency Response Organization Training IR 05000482/19990051999-09-21021 September 1999 Insp Rept 50-482/99-05 Has Been Rescheduled for Next Yr.Insp Rept Will Not Be Issued IR 05000482/19990131999-09-20020 September 1999 Insp Rept 50-482/99-13 on 990725-0904.Noncited Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19990121999-09-14014 September 1999 Insp Rept 50-482/99-12 on 990816-20.No Violations Noted. Major Areas Inspected:Solid Radioactive Waste Mgt Program, Radioactive Matls Transportation Program,Facilities & Equipment,Staff Kowledge & Performance & Staff Training IR 05000482/19990161999-08-26026 August 1999 Insp Rept 50-482/99-16 on 990809-13.No Violations Noted. Major Areas Inspected:Planning & Preparation,Program to Maintain Occupational Exposure Alara,Temporary Shielding Program & Hot Spot Reduction Program IR 05000482/19990081999-08-18018 August 1999 Insp Rept 50-482/99-08 on 990613-0724.Noncited Violation Identified.Major Areas Inspected:Operations,Maint & Plant Support IR 05000482/19990111999-08-13013 August 1999 Insp Rept 50-482/99-11 on 990712-16.No Violations Noted. Major Areas Inspected:Review of Radiological Environ Monitoring Program,Meterological Monitoring Prgram & Results of Licensee Investigation of 990525 Personnel Event IR 05000482/19990151999-08-10010 August 1999 Canceled Insp Rept 50-482/99-15.No Inspection Rept Will Be Issued for This Rept Number IR 05000482/19990071999-07-15015 July 1999 Insp Rept 50-482/99-07 on 990614-18.No Violations Noted. Major Areas Inspected:Routine Insp Reviewed Radiation Protection Program Activities IR 05000482/19990061999-07-0202 July 1999 Insp Rept 50-482/99-06 on 990502-0612.Two Violations Occurred & Being Treated as Noncited Violations.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19990031999-05-21021 May 1999 Insp Rept 50-482/99-03 on 990321-0501.Four NCVs Noted.Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000482/19990041999-05-0505 May 1999 Insp Rept 50-482/99-04 on 990405-09.No Violations Noted. Major Areas Inspected:Licensee Implementation of Facility Inservice Insp Program & Followup Review of Previously Identified Insp Findings IR 05000482/19990021999-04-0909 April 1999 Insp Rept 50-482/99-02 on 990207-0320.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19990011999-01-26026 January 1999 Insp Rept 50-482/99-01 on 990111-14.No Violations Noted. Major Areas Inspected:Testing & Maintenance,Protected Area Barriers & Detection Aids,Vital Area Barriers & Detection Aids,Compensatory Measures & Security Sys Power Supply IR 05000482/19980201999-01-15015 January 1999 Insp Rept 50-482/98-20 on 981115-1226.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000482/19980161998-12-10010 December 1998 Informs That Insp Rept 50-482/98-16 Was Combined with Insp Rept 50-482/98-12,therefore,no Rept Will Be Issued for Rept 50-482/98-16 ML20196H3711998-12-0303 December 1998 Insp Rept 50-482/98-19 on 981002-1114.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support.Licensee Response to Road Closure Due to Flooding within 10-mile Emergency Zone Was Excellent ML20155A1871998-10-22022 October 1998 Insp Rept 50-482/98-17 on 980823-1003.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support.Use of Fire Protection Sys Pumps for Purposes Other than Fire Protection Constituted Degradation of Sys IR 05000482/19980181998-10-0505 October 1998 Insp Rept 50-482/98-18 on 980921-25.No Violations Noted. Major Areas Inspected:Licensee Physical Security Program Including Access Authorization,Alarm Stations,Assessment Aids,Communications & Security Program Plan & Procedures ML20154C7071998-09-29029 September 1998 Insp Rept 50-482/98-12 on 980323-0410 & 0622-25.Violations Noted.Major Areas Inspected:Engineering & Plant Support IR 05000482/19980151998-09-0404 September 1998 Insp Rept 50-482/98-15 on 980712-0822.No Violations Noted. Major Areas Inspected:Operation,Maint,Engineering & Plant Support ML20236T1461998-07-23023 July 1998 Insp Rept 50-482/98-14 on 980531-0711.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19980131998-06-12012 June 1998 Insp Rept 50-482/98-13 on 980419-0530.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20216A9051998-05-0606 May 1998 Insp Rept 50-482/98-10 on 980308-0418.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20217M3691998-04-30030 April 1998 Insp Rept 50-482/98-07 on 980330-0403.No Violations Noted. Major Areas Inspected:Operational Status of Licensee Emergency Preparedness Program ML20217M5491998-04-0202 April 1998 Insp Rept 50-482/98-11 on 980316-20.Violations Noted.Major Areas Inspected:Implementation of Solid Radwaste Mgt & Radioactive Waste/Matls Transportation Programs IR 05000482/19980041998-04-0101 April 1998 Insp Rept 50-482/98-04 on 980125-0307.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19980081998-03-30030 March 1998 Insp Rept 50-482/98-08 on 980302-06.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support ML20216G5761998-03-13013 March 1998 Insp Rept 50-482/98-09 on 980223-27.Violation Noted.Major Areas Inspected:Radiation Protection Program IR 05000482/19980021998-03-0606 March 1998 Insp Rept 50-482/98-02 on 980202-06.No Violations Noted. Major Areas Inspected:Maint,Engineering & Emergency Preparedness IR 05000482/19980061998-02-27027 February 1998 Insp Rept 50-482/98-06 on 980202-06.No Violations Noted. Major Areas Inspected:Review of Radiation Protection Program Activities ML20203K9181998-02-26026 February 1998 Insp Rept 50-482/98-03 on 980202-06.No Violations Noted. Major Areas Inspected:Implementation of Liquid & Gaseous Radwaste Mgt Program,Training & Qualifications,Qa Oversight, Facilities & Equipment & Annual Repts ML20203H5341998-02-23023 February 1998 Insp Rept 50-482/97-201 on 971103-980109.No Violations Noted.Major Areas Inspected:Capability of RHR & CCW Sys to Perform Safety Functions Required by Design Bases & Adherence of Sys to Design & Licensing Bases IR 05000482/19970211998-02-0909 February 1998 Insp Rept 50-482/97-21 Cancelled IR 05000482/19970231998-01-29029 January 1998 Insp Rept 50-482/97-23 on 971214-980124.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19980011998-01-23023 January 1998 Insp Rept 50-482/98-01 on 980112-16.No Violation Noted. Major Areas Inspected:Licensee Physical Security Program, Including Protected Area Barriers & Detection Aids,Vital Area Barriers & Detection Aids & Compensatory Measures ML20198A7641997-12-29029 December 1997 Insp Rept 50-482/97-22 on 971102-1213.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19970191997-11-25025 November 1997 Insp Rept 50-482/97-19 on 970922-1102.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19970201997-11-14014 November 1997 Insp Rept 50-482/97-20 on 971020-24.Violations Noted.Major Areas Inspected:Planning & Preparation,External & Internal Exposure Controls,Control of Radioactive Material & Contamination,Training & Qualifications IR 05000482/19970171997-10-29029 October 1997 Insp Rept 50-482/97-17 on 970929-1010.No Violations Noted. Major Areas Inspected:Maint IR 05000482/19970151997-10-22022 October 1997 Insp Rept 50-482/97-15 on 970922-25.no Violations Noted. Major Areas Inspected:Radiological Protection & Chemistry Controls & Status of Radiological Protection & Chemistry Facilities & Equipment IR 05000482/19970161997-10-21021 October 1997 Insp Rept 50-482/97-16 on 971006-10.No Violations Noted. Major Areas Inspected:Licensee Physical Security Program Included Access Authorization,Alarm Stations,Communications, Access Control of Personnel & Packages IR 05000482/19970141997-10-0202 October 1997 Insp Rept 50-482/97-14 on 970810-0920.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19973011997-09-17017 September 1997 Insp Rept 50-482/97-301 on 970825-29.No Violations Noted. Major Areas Inspected:Operations IR 05000482/19970121997-09-0404 September 1997 Insp Rept 50-482/97-12 on 970811-15.No Violations Noted. Major Areas Inspected:Licensed Operator Requalification Program ML20210N6941997-08-21021 August 1997 Insp Rept 50-482/97-11 on 970629-0809.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20141J9561997-08-17017 August 1997 Insp Rept 50-482/97-13 on 970624-27 & 0708.No Violations Noted.Major Areas Inspected:Followup on licensee-identified Welding Work Control Issues by Observation of Welding & Welding Matl Control Activities ML20140E8511997-06-0606 June 1997 Insp Rept 50-482/97-09 on 970406-0517.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support,Re Violation Which Cites Licensee Failure to Comply W/Security Escort Requirements IR 05000482/19970031997-05-0202 May 1997 Insp Rept 50-482/97-03 on 970414-17.No Violations Noted. Major Areas Inspected:Operations ML20140E7261997-04-25025 April 1997 Insp Rept 50-482/97-08 on 970223-0405.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering, Plant Support & Plant Status 1999-09-21
[Table view] Category:NRC-GENERATED
MONTHYEARIR 05000482/19990091999-10-0707 October 1999 Insp Rept 50-482/99-09 on 990830-0903.No Violations Noted. Major Areas Inspected:Events,Emergency Preparedness Facilities & Equipment,Emergency Plan & Implementing Procedures & Emergency Response Organization Training IR 05000482/19990051999-09-21021 September 1999 Insp Rept 50-482/99-05 Has Been Rescheduled for Next Yr.Insp Rept Will Not Be Issued IR 05000482/19990131999-09-20020 September 1999 Insp Rept 50-482/99-13 on 990725-0904.Noncited Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19990121999-09-14014 September 1999 Insp Rept 50-482/99-12 on 990816-20.No Violations Noted. Major Areas Inspected:Solid Radioactive Waste Mgt Program, Radioactive Matls Transportation Program,Facilities & Equipment,Staff Kowledge & Performance & Staff Training IR 05000482/19990161999-08-26026 August 1999 Insp Rept 50-482/99-16 on 990809-13.No Violations Noted. Major Areas Inspected:Planning & Preparation,Program to Maintain Occupational Exposure Alara,Temporary Shielding Program & Hot Spot Reduction Program IR 05000482/19990081999-08-18018 August 1999 Insp Rept 50-482/99-08 on 990613-0724.Noncited Violation Identified.Major Areas Inspected:Operations,Maint & Plant Support IR 05000482/19990111999-08-13013 August 1999 Insp Rept 50-482/99-11 on 990712-16.No Violations Noted. Major Areas Inspected:Review of Radiological Environ Monitoring Program,Meterological Monitoring Prgram & Results of Licensee Investigation of 990525 Personnel Event IR 05000482/19990151999-08-10010 August 1999 Canceled Insp Rept 50-482/99-15.No Inspection Rept Will Be Issued for This Rept Number IR 05000482/19990071999-07-15015 July 1999 Insp Rept 50-482/99-07 on 990614-18.No Violations Noted. Major Areas Inspected:Routine Insp Reviewed Radiation Protection Program Activities IR 05000482/19990061999-07-0202 July 1999 Insp Rept 50-482/99-06 on 990502-0612.Two Violations Occurred & Being Treated as Noncited Violations.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19990031999-05-21021 May 1999 Insp Rept 50-482/99-03 on 990321-0501.Four NCVs Noted.Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000482/19990041999-05-0505 May 1999 Insp Rept 50-482/99-04 on 990405-09.No Violations Noted. Major Areas Inspected:Licensee Implementation of Facility Inservice Insp Program & Followup Review of Previously Identified Insp Findings IR 05000482/19990021999-04-0909 April 1999 Insp Rept 50-482/99-02 on 990207-0320.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19990011999-01-26026 January 1999 Insp Rept 50-482/99-01 on 990111-14.No Violations Noted. Major Areas Inspected:Testing & Maintenance,Protected Area Barriers & Detection Aids,Vital Area Barriers & Detection Aids,Compensatory Measures & Security Sys Power Supply IR 05000482/19980201999-01-15015 January 1999 Insp Rept 50-482/98-20 on 981115-1226.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000482/19980161998-12-10010 December 1998 Informs That Insp Rept 50-482/98-16 Was Combined with Insp Rept 50-482/98-12,therefore,no Rept Will Be Issued for Rept 50-482/98-16 ML20196H3711998-12-0303 December 1998 Insp Rept 50-482/98-19 on 981002-1114.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support.Licensee Response to Road Closure Due to Flooding within 10-mile Emergency Zone Was Excellent ML20155A1871998-10-22022 October 1998 Insp Rept 50-482/98-17 on 980823-1003.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support.Use of Fire Protection Sys Pumps for Purposes Other than Fire Protection Constituted Degradation of Sys IR 05000482/19980181998-10-0505 October 1998 Insp Rept 50-482/98-18 on 980921-25.No Violations Noted. Major Areas Inspected:Licensee Physical Security Program Including Access Authorization,Alarm Stations,Assessment Aids,Communications & Security Program Plan & Procedures ML20154C7071998-09-29029 September 1998 Insp Rept 50-482/98-12 on 980323-0410 & 0622-25.Violations Noted.Major Areas Inspected:Engineering & Plant Support IR 05000482/19980151998-09-0404 September 1998 Insp Rept 50-482/98-15 on 980712-0822.No Violations Noted. Major Areas Inspected:Operation,Maint,Engineering & Plant Support ML20236T1461998-07-23023 July 1998 Insp Rept 50-482/98-14 on 980531-0711.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19980131998-06-12012 June 1998 Insp Rept 50-482/98-13 on 980419-0530.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20216A9051998-05-0606 May 1998 Insp Rept 50-482/98-10 on 980308-0418.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20217M3691998-04-30030 April 1998 Insp Rept 50-482/98-07 on 980330-0403.No Violations Noted. Major Areas Inspected:Operational Status of Licensee Emergency Preparedness Program ML20217M5491998-04-0202 April 1998 Insp Rept 50-482/98-11 on 980316-20.Violations Noted.Major Areas Inspected:Implementation of Solid Radwaste Mgt & Radioactive Waste/Matls Transportation Programs IR 05000482/19980041998-04-0101 April 1998 Insp Rept 50-482/98-04 on 980125-0307.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19980081998-03-30030 March 1998 Insp Rept 50-482/98-08 on 980302-06.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support ML20216G5761998-03-13013 March 1998 Insp Rept 50-482/98-09 on 980223-27.Violation Noted.Major Areas Inspected:Radiation Protection Program IR 05000482/19980021998-03-0606 March 1998 Insp Rept 50-482/98-02 on 980202-06.No Violations Noted. Major Areas Inspected:Maint,Engineering & Emergency Preparedness IR 05000482/19980061998-02-27027 February 1998 Insp Rept 50-482/98-06 on 980202-06.No Violations Noted. Major Areas Inspected:Review of Radiation Protection Program Activities ML20203K9181998-02-26026 February 1998 Insp Rept 50-482/98-03 on 980202-06.No Violations Noted. Major Areas Inspected:Implementation of Liquid & Gaseous Radwaste Mgt Program,Training & Qualifications,Qa Oversight, Facilities & Equipment & Annual Repts ML20203H5341998-02-23023 February 1998 Insp Rept 50-482/97-201 on 971103-980109.No Violations Noted.Major Areas Inspected:Capability of RHR & CCW Sys to Perform Safety Functions Required by Design Bases & Adherence of Sys to Design & Licensing Bases IR 05000482/19970211998-02-0909 February 1998 Insp Rept 50-482/97-21 Cancelled IR 05000482/19970231998-01-29029 January 1998 Insp Rept 50-482/97-23 on 971214-980124.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19980011998-01-23023 January 1998 Insp Rept 50-482/98-01 on 980112-16.No Violation Noted. Major Areas Inspected:Licensee Physical Security Program, Including Protected Area Barriers & Detection Aids,Vital Area Barriers & Detection Aids & Compensatory Measures ML20198A7641997-12-29029 December 1997 Insp Rept 50-482/97-22 on 971102-1213.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19970191997-11-25025 November 1997 Insp Rept 50-482/97-19 on 970922-1102.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19970201997-11-14014 November 1997 Insp Rept 50-482/97-20 on 971020-24.Violations Noted.Major Areas Inspected:Planning & Preparation,External & Internal Exposure Controls,Control of Radioactive Material & Contamination,Training & Qualifications IR 05000482/19970171997-10-29029 October 1997 Insp Rept 50-482/97-17 on 970929-1010.No Violations Noted. Major Areas Inspected:Maint IR 05000482/19970151997-10-22022 October 1997 Insp Rept 50-482/97-15 on 970922-25.no Violations Noted. Major Areas Inspected:Radiological Protection & Chemistry Controls & Status of Radiological Protection & Chemistry Facilities & Equipment IR 05000482/19970161997-10-21021 October 1997 Insp Rept 50-482/97-16 on 971006-10.No Violations Noted. Major Areas Inspected:Licensee Physical Security Program Included Access Authorization,Alarm Stations,Communications, Access Control of Personnel & Packages IR 05000482/19970141997-10-0202 October 1997 Insp Rept 50-482/97-14 on 970810-0920.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19973011997-09-17017 September 1997 Insp Rept 50-482/97-301 on 970825-29.No Violations Noted. Major Areas Inspected:Operations IR 05000482/19970121997-09-0404 September 1997 Insp Rept 50-482/97-12 on 970811-15.No Violations Noted. Major Areas Inspected:Licensed Operator Requalification Program ML20210N6941997-08-21021 August 1997 Insp Rept 50-482/97-11 on 970629-0809.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20141J9561997-08-17017 August 1997 Insp Rept 50-482/97-13 on 970624-27 & 0708.No Violations Noted.Major Areas Inspected:Followup on licensee-identified Welding Work Control Issues by Observation of Welding & Welding Matl Control Activities ML20140E8511997-06-0606 June 1997 Insp Rept 50-482/97-09 on 970406-0517.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support,Re Violation Which Cites Licensee Failure to Comply W/Security Escort Requirements IR 05000482/19970031997-05-0202 May 1997 Insp Rept 50-482/97-03 on 970414-17.No Violations Noted. Major Areas Inspected:Operations ML20140E7261997-04-25025 April 1997 Insp Rept 50-482/97-08 on 970223-0405.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering, Plant Support & Plant Status 1999-09-21
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARIR 05000482/19990091999-10-0707 October 1999 Insp Rept 50-482/99-09 on 990830-0903.No Violations Noted. Major Areas Inspected:Events,Emergency Preparedness Facilities & Equipment,Emergency Plan & Implementing Procedures & Emergency Response Organization Training IR 05000482/19990051999-09-21021 September 1999 Insp Rept 50-482/99-05 Has Been Rescheduled for Next Yr.Insp Rept Will Not Be Issued IR 05000482/19990131999-09-20020 September 1999 Insp Rept 50-482/99-13 on 990725-0904.Noncited Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19990121999-09-14014 September 1999 Insp Rept 50-482/99-12 on 990816-20.No Violations Noted. Major Areas Inspected:Solid Radioactive Waste Mgt Program, Radioactive Matls Transportation Program,Facilities & Equipment,Staff Kowledge & Performance & Staff Training IR 05000482/19990161999-08-26026 August 1999 Insp Rept 50-482/99-16 on 990809-13.No Violations Noted. Major Areas Inspected:Planning & Preparation,Program to Maintain Occupational Exposure Alara,Temporary Shielding Program & Hot Spot Reduction Program IR 05000482/19990081999-08-18018 August 1999 Insp Rept 50-482/99-08 on 990613-0724.Noncited Violation Identified.Major Areas Inspected:Operations,Maint & Plant Support IR 05000482/19993011999-08-17017 August 1999 Exam Rept 50-482/99-301 on 990726-29.Exam Results:All Nine Applicants Passed Written Exams & Exhibited No Broad Knowledge or Training Weaknesses IR 05000482/19990111999-08-13013 August 1999 Insp Rept 50-482/99-11 on 990712-16.No Violations Noted. Major Areas Inspected:Review of Radiological Environ Monitoring Program,Meterological Monitoring Prgram & Results of Licensee Investigation of 990525 Personnel Event IR 05000482/19990151999-08-10010 August 1999 Canceled Insp Rept 50-482/99-15.No Inspection Rept Will Be Issued for This Rept Number IR 05000482/19990071999-07-15015 July 1999 Insp Rept 50-482/99-07 on 990614-18.No Violations Noted. Major Areas Inspected:Routine Insp Reviewed Radiation Protection Program Activities IR 05000482/19990061999-07-0202 July 1999 Insp Rept 50-482/99-06 on 990502-0612.Two Violations Occurred & Being Treated as Noncited Violations.Major Areas Inspected:Operations,Maint,Engineering & Plant Support PNO-IV-99-029, on 990625,female Licensee Employee Was Discovered Contaminated in Facial Area.Licensee Convened Incident Investigation Team to Assess Event.Worker Received Total Effective Dose Equivalent of Approx 7 Mrem1999-06-28028 June 1999 PNO-IV-99-029:on 990625,female Licensee Employee Was Discovered Contaminated in Facial Area.Licensee Convened Incident Investigation Team to Assess Event.Worker Received Total Effective Dose Equivalent of Approx 7 Mrem IR 05000482/19990031999-05-21021 May 1999 Insp Rept 50-482/99-03 on 990321-0501.Four NCVs Noted.Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000482/19990041999-05-0505 May 1999 Insp Rept 50-482/99-04 on 990405-09.No Violations Noted. Major Areas Inspected:Licensee Implementation of Facility Inservice Insp Program & Followup Review of Previously Identified Insp Findings IR 05000482/19990021999-04-0909 April 1999 Insp Rept 50-482/99-02 on 990207-0320.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000482/19990011999-01-26026 January 1999 Insp Rept 50-482/99-01 on 990111-14.No Violations Noted. Major Areas Inspected:Testing & Maintenance,Protected Area Barriers & Detection Aids,Vital Area Barriers & Detection Aids,Compensatory Measures & Security Sys Power Supply IR 05000482/19980201999-01-15015 January 1999 Insp Rept 50-482/98-20 on 981115-1226.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000482/19980161998-12-10010 December 1998 Informs That Insp Rept 50-482/98-16 Was Combined with Insp Rept 50-482/98-12,therefore,no Rept Will Be Issued for Rept 50-482/98-16 ML20196H3711998-12-0303 December 1998 Insp Rept 50-482/98-19 on 981002-1114.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support.Licensee Response to Road Closure Due to Flooding within 10-mile Emergency Zone Was Excellent PNO-IV-98-051, on 981102,flooding in Vicinity of Wolf Creek Generating Station Occurred.Licensee Has Been in Close Contact with Army Corps of Engineers,Region VII Ofc of Federal Emergency Mgt Agency Emergency Organizations1998-11-0505 November 1998 PNO-IV-98-051:on 981102,flooding in Vicinity of Wolf Creek Generating Station Occurred.Licensee Has Been in Close Contact with Army Corps of Engineers,Region VII Ofc of Federal Emergency Mgt Agency Emergency Organizations ML20155A1871998-10-22022 October 1998 Insp Rept 50-482/98-17 on 980823-1003.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support.Use of Fire Protection Sys Pumps for Purposes Other than Fire Protection Constituted Degradation of Sys IR 05000482/19980181998-10-0505 October 1998 Insp Rept 50-482/98-18 on 980921-25.No Violations Noted. Major Areas Inspected:Licensee Physical Security Program Including Access Authorization,Alarm Stations,Assessment Aids,Communications & Security Program Plan & Procedures ML20154C7031998-09-29029 September 1998 Notice of Violations from Insp on 980323-0410 & 0622-25. Violations Noted:Without Prior Commission Approval & Without Performing Written Safety Evaluations,Licensee Made Changes Described in USAR Re Unreviewed Safety Question ML20154C7071998-09-29029 September 1998 Insp Rept 50-482/98-12 on 980323-0410 & 0622-25.Violations Noted.Major Areas Inspected:Engineering & Plant Support IR 05000482/19980151998-09-0404 September 1998 Insp Rept 50-482/98-15 on 980712-0822.No Violations Noted. Major Areas Inspected:Operation,Maint,Engineering & Plant Support ML20236T1461998-07-23023 July 1998 Insp Rept 50-482/98-14 on 980531-0711.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20236T1431998-07-23023 July 1998 Notice of Violation from Insp on 980531-0711.Violation Noted:On 980604,technicians Placed Heavy Door & Frame in Control Room Equipment Cabinet Adjacent to Train a Protection Sys Logic Cabinets IR 05000482/19980131998-06-12012 June 1998 Insp Rept 50-482/98-13 on 980419-0530.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20249A0341998-06-12012 June 1998 Notice of Violation from Insp on 980419-0530.Violation Noted:On 980317,electricians Removed Breaker NG001AGF1 While Clearance Order 98-0250-EF Relied on Procedure Mge EOOP-11 to Establish Isolation of Breaker from Bus ML20248B6471998-05-27027 May 1998 Notice of Violation from NRC Investigation on 961224-980206. Violation Noted:On 961211,S Buehne Intentionally Submitted Info to Licensee Known to Be Inaccurate & Info Submitted to NRC ML20247Q3461998-05-22022 May 1998 SALP Rept 50-482/98-99 for Period 970406-980418 ML20216A8881998-05-0606 May 1998 Notice of Violation from Insp on 980308-0418.Violation Noted:On 980410,an Accessible High Radiation Area on Radwaste Bldg Roof W/Dose Rate of Approx 400 Mr/H at 18 Inch Was Not Posted as High Radiation Area ML20216A9051998-05-0606 May 1998 Insp Rept 50-482/98-10 on 980308-0418.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20217M3691998-04-30030 April 1998 Insp Rept 50-482/98-07 on 980330-0403.No Violations Noted. Major Areas Inspected:Operational Status of Licensee Emergency Preparedness Program ML20217E0851998-04-23023 April 1998 Notice of Violation from Insp on 970624-27.Violation Noted: Licensee Identified That Unauthorized Work, (Work Outside Scope of Assigned Work Package Tasks & Applicable Procedures) Performed & Not Documented ML20217M5291998-04-0202 April 1998 Notice of Violation from Insp on 980316-20.Violation Noted: Inspector Identified Seven Radioactive Matl Containers Located in Radwaste Storage Bldg ML20217M5491998-04-0202 April 1998 Insp Rept 50-482/98-11 on 980316-20.Violations Noted.Major Areas Inspected:Implementation of Solid Radwaste Mgt & Radioactive Waste/Matls Transportation Programs IR 05000482/19980041998-04-0101 April 1998 Insp Rept 50-482/98-04 on 980125-0307.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20217H6431998-04-0101 April 1998 Notice of Violation from Insp on 980125-0307.Violation Noted:Operators Failed to Log Entry Into Action Statement for TS 3.1.3.5 Shutdown Rods Inserted Beyond Rod Insertion Limits IR 05000482/19980081998-03-30030 March 1998 Insp Rept 50-482/98-08 on 980302-06.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support ML20216G5661998-03-13013 March 1998 Notice of Violation from Insp on 980223-27.Violation Noted: Proper Surveys Were Not Performed to Prevent Unconditional Release of Radioactive Matls Greater than Release Criteria ML20216G5761998-03-13013 March 1998 Insp Rept 50-482/98-09 on 980223-27.Violation Noted.Major Areas Inspected:Radiation Protection Program IR 05000482/19980021998-03-0606 March 1998 Insp Rept 50-482/98-02 on 980202-06.No Violations Noted. Major Areas Inspected:Maint,Engineering & Emergency Preparedness IR 05000482/19980061998-02-27027 February 1998 Insp Rept 50-482/98-06 on 980202-06.No Violations Noted. Major Areas Inspected:Review of Radiation Protection Program Activities ML20203K9181998-02-26026 February 1998 Insp Rept 50-482/98-03 on 980202-06.No Violations Noted. Major Areas Inspected:Implementation of Liquid & Gaseous Radwaste Mgt Program,Training & Qualifications,Qa Oversight, Facilities & Equipment & Annual Repts ML20203K2831998-02-26026 February 1998 Insp Rept 50-482/98-301 on 980217.No Violations Noted.Major Areas Inspected:Operations,Including Evaluation of Competency of 2 Retake RO & 2 SRO Retake License Applicants for Issuance of Operating Licenses at Facility ML20203H5341998-02-23023 February 1998 Insp Rept 50-482/97-201 on 971103-980109.No Violations Noted.Major Areas Inspected:Capability of RHR & CCW Sys to Perform Safety Functions Required by Design Bases & Adherence of Sys to Design & Licensing Bases IR 05000482/19970211998-02-0909 February 1998 Insp Rept 50-482/97-21 Cancelled ML20199H9141998-01-29029 January 1998 Notice of Violation from Insp on 971214-980124.Violation Noted:Technicians Failed to Follow Procedure Steps by Removing Vendor Wire & Reversed Variable Transformer Leads IR 05000482/19970231998-01-29029 January 1998 Insp Rept 50-482/97-23 on 971214-980124.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support 1999-09-21
[Table view] |
Text
r
.
.
ENCLOSURE U.S. NUCLEAR REGULATORY COMMISSION
REGION IV
Docket No.: 50-482 License No.: NPF-42 Report No.: 50-482/99-12 Licensee: Wolf Creek Nuclear Operating Corporation Facility: Wolf Creek Generating Station Location: 1550 Oxen Lane, NE Burlington, Kansas Dates: August 16 20,1999 Inspector (s): James S. Dodson, Radiation Specialist Plant Support Branch Approved By: Gail M. Good, Chief, Plant Support Branch Division of Reactor Safety Attachment: Supplemental Information l
!
l l
I l
!
i l
l 9909210179 9909 4 PDR G ADOCK 05000482 pg t
l
.
! -2-EXECUTIVE SUMMARY Wolf Creek Generating Station NRC inspection Report No. 50-482/99-12 The NRC conducted an inspection of the so!id radioactive waste management and radioactive material transportation programs. Areas reviewed included: the solid radioactive waste management program, radioactive material transportation program, facilities and equipment, staff knowledge and performance, staff training and qualifications, and quality assurance activitie Plant Support
- The licensee met regulatory requirements associated with the solid radioactive waste management program. Radioactive material was correctly stored and controlle Radioactive waste was correctly classified and stabilized for burial. Waste manifests were prepared in accordance with regulatory requirements (Section R1.1).
- The licensee met regulatory requirements for the packaging and shipping of radioactise materials and radioactive waste. Packages were properly marked and labeled, and radioactive material transport vehicles were properly placarded. Shipping documentation contained the required information (Section R1.2).
- Some problems were observed with the material condition of the licensee's radwaste j facilities; one pipe tee and one valve showed significant surface rust (Section R2). I
- The individuals responsible for training, routine oversight, transfer, packaging, and transport of radioactive material were knowledgeable of training and retraining requirements. Additionally, these individuals were knowledgeable of waste classification, packaging, marking, labeling, storage, documentation, vendor supplied computer software operation, and radioactive material transportation regulations (Section R4).
- The licensee provided solid radwaste and transportation personnel with the appropriate initial training and retraining (Section RS).
- The biennial quality assurance audit of the Process Control Program was not comprehensive. The audit only addressed observation of a radwaste shipment, reviews of task observations, a summary of Performance improvement Requests, and regulatory commitments. The Process Control Program contained approximately 13 areas and implementing procedures for processing, packaging, and transportation of radioactive wastes. As a result, this narrowly focused audit provided management with limited information needed to assess the program's performance (Section R7).
l C
-
I.
l l
l
.
l 3-
'
Report Details
!
! IV. Plant Support i R1 Radiological Protection and Chemistry Controls l
- R Solid Radioactive Waste Manaaement Proaram Inspection Scope (86750)
The inspector interviewed licensee personnel and reviewed the following program areas:
l l
- Waste storage and container accountability
'
. Waste stream sampling results
. Waste classification
- Waste characteristics
. Waste shipment manifests Observations and Findinas Waste Storaae and Container Accountability During tours of the radiological controlled areas, the inspector confirmed that radioactive l
waste was stored in accordance with commitments in the Updated Final Safety Analysis l Report, Chapter 11.4. The inspector verified that randomly selected radioactive material containers were properly labeled and confirmed that the licensee's tracking system listed the correct location and status of the container Waste Stream Samolina The inspector reviewed the analysis results and the associated evaluations for the eight identified waste streams. The inspector determined that sampling and analyses were completed at the required intervals. The scaling factors used in the vendor supplied computer code were verified with current analysis results as required by procedur .. Analyses were performed by a vendor laboratory and the licensee as required by procedure. During the review of selected waste stream analysis packages, the inspector noted that waste stream analysis package No. 9 was missing the Independent Laboratory Data Checklist in accordance with management expectations. The licensee entered the item in the corrective action program.
!
! Waste Classification i
I The licensee used a vendor supplied computer scftware code to perform the calculations necessary to classify radioactive waste. The inspector reviewed sample results from selected radioactive waste shipments and confirmed that the waste shipments were properly classified in accordance with 10 CFR 61.5 V,
.
-4 Waste Characteristics ,
Through record review and observations, the inspector confirmed that the licensee met the structural integrity requirements of 10 CFR 61.56 (b)(1) by using high integrity containers. No adverse findings relating to the licensee's radioactive waste characteristics had been identified by burial site representative Manifests The inspector reviewed random shipping documentation and confirmed that the licensee accurately prepared manifests and included the information required by 10 CFR Part 20, Appendix G. The shipment manifests included a certification that the transported material was properly classified, described, packaged, marked, labeled, and in proper ;
condition for transport. The certification was signed and dated by an authorized l licensee representativ l
'
l Conclusions The licensee met regulatory requirements associated with the solid radioactive waste management program. Radioactive material was correctly stored and controlle Radioactive waste was correctly classified and stabilized for burial. Waste manifests were prepared in accordance with regulatory requirement R1.2 Radioactive Material Transportation Proaram Inspection Scoce (86750)
The inspector interviewed licensee personnel and reviewed selected examples of the following materials: l
. Packaging
. Radiation surveys ,
. Shipping paper documentation l
= Package marking and labeling
. Loading and storage, blocking and bracing
. Vehicle placarding i
. Driver instructions
. Emergency response information ; Observations and Findinas Packaaina The inspector reviewed A, values for selected radionuclides in the licensee's waste classification computer data base and confirmed that they matched the values in 49 CFR 173.435. The licensee maintained records that documented Type B packages used by the licensee were designed to meet the applicable requirements specified in 10 CFR 71.1 ,
.
5-Radiation Surveys Radiation surveys were conducted by the inspector during tours of the radioactive waste l
'
processing and storage facilities to ensure that external radiation levels were within the allowable limits of 49 CFR 173.441. The inspector verified that radioactive waste package external radiation levels were within allowable limits for randomly selected package Packaae Markina. Labelino. and Loadina and Vehicle Placardina The inspector reviewed shipping documentation packages and determined that packages were properly marked and labeled and that radioactive material transport vehicles were properly placarded in accordance with 49 CFR 172.504 and 172.50 Shiocina Pacers and Documentation The inspector reviewed selected examples of shipping documentation and confirmed that the licensee provided the shipping papers and information required by 49 CFR Part 172, Subpart C, and the emergency response information required by 49 CFR Part 172, Subpart G. Additionally, the inspector verified that shipping permits, licenses, certificates of compliance, user lists, and shipping regulations were curren c. Conclusions l The licensee met regulatory requirements for the packaging and shipping of radioactive materials and radioactive waste. Packages were properly maued and labeled, and radioactive material transport vehicles were properly placarded. Shipping documentation contained the required informatio R2 Status of Radiological Protection and Chemistry Facilities and Equipment a. Insoection Scoce (86750)
The inspector reviewed associated documentation and toured the radwaste building and interim onsite storage facility. The inspector also viewed radwaste storage tanks, pumps, valves, and associated pipin b. Observations and Findinos The licensee made no significant changes to solid radwaste f acilities since the last inspection in this area. Changes in equipment were reflected in the current versions of the Process Control Program and implementing procedures. The inspector noted no deviations from commitments in the Updated Final Safety Analysis Report, Chapter i 11.4, due to the revision which was in process to correct both fidelity and terminology
'
issues identified by the license During the tours of the radwaste building and interim onsite storage facility, the inspector noted that the housekeeping was acceptable.
l l J
.
.
6-To selectively review the material conditions in the licensee's radwaste facility, the inspector asked to see radwaste storage tanks, pumps, valves and associated pipin The inspector noted that there were problems with the material condition of a reducer pipe tee and Valve HBV-422 in floor drain tank room No. A. Specifically, there were signs of significant sudace rust on the pipe tee and in some areas on the valve. The licensee initiated Work Request WR#99-016899 to address this issu c. Conclusions Housekeeping in the solid radwaste facilities was acceptable. Some problems were observed with the material condition of the licensee's radwaste facilities; one pipe tee and one valve showed significant surface rus R4 Staff Knowledge and Performance a. Insoection Scope (86750)
The inspector interviewed a quality assurance specialist, health physics supervisor radwaste, and the training instructor involved in the radioactive material transportation program, b. Observations and Findinas The quality assurance specialist who conducted quality assurance observations and surveillances was knowledgeable of regulatory and procedural requirements for solid radioactive waste management and transportation. The training instructor responsible for radwaste personnel training was knowledgeable of the regulatory training and retraining requirements. The health physics supervisor radwaste was knowledgeable of radioactive waste classification, packaging, marking, labeling, storage, documentation, vendor supplied computer software operation, and radioactive material transportation regulation c. Conclusions The individuals responsible for training, routine oversight, transfer, packaging, and transport of radioactive material were knowledgeable of training and retraining requirements. Additionally, these individuals were knowledgeable of waste classification, packaging, marking, labeling, storage, documentation, vendor supplied computer software operation, and radioactive material transportation regulation R5 Staff Training and Qualification a. Inspection Scope (86750)
The inspector reviewed initial training lesson plans, retraining lesson plans, and training records for the health physics supervisor radwaste, and two radwaste technician .
.
-7- Observations and Findinas Training lesson plans and records confirmed that the licensee provided the appropriate initial training and periodic retraining in Department of Transportation and NRC regulatory requirements. Additionally, the training and retraining programs included instructions and a review of operating procedures for personnelinvolved in the transfer, packaging, and trarssport of radioactive materia Conclusions The licensee provided solid radwaste and transportation personnel with the appropriate initial training and retrainin R7 Quality Assurance in Radiological Protection and Chemistry Activities Inspection Scope (86750)
The inspector interviewed licensee personnel and reviewed the following items:
. Quality assurance audit
. Quality assurance surveillances
. Vendor audits
. Self-assessments
. Performance improvement Requests Observations and Findinas The licensee conducted one audit, WCNOC OA Audit K-508, since the previous NRC inspection of solid radioactive waste management and transportation activitie Procedure AP 20A-003, Revision 3, " Audit / Surveillance Scheduling," identified the 24-month audit elements as the Process Control Program, implementing procedures for processing, packaging, and transportation of radioactive wastes including Type B and fissile quantities of radioactive materials and low-level radioactive waste. The elements of the Process Control Program, as delineated in Procedure AP 31 A-100, Revision 2,
" Solid Radwaste Process Control Program," were: waste stream identification, solidification / encapsulation methods, operation and maintenance of dewatering equipment, high integrity container usage, waste characterization, waste classification, waste packaging, regulatory requirements, quality control, certifications, waste management facility requi ements, administrative controls, and surveillance requirement The scope of the program audit included observation of a radwaste shipment, a review of task observations, a summary of Performance improvement Requests, and regulatory commitments. Due to the narrow scope of the audit, the inspector determined that the audit was not comprehensiv _
Since the previous inspection, quality assurance personnel conducted four observation . These observations were general and addressed segments of activities and practice I l
i
- l
\ \
I
.
.
-8-The observations provided minimal oversight of radwaste management and transportation activitie Three vendor audits were conducted for radwaste management related support functions. The vendor services were for the waste stream analysis laboratory and radwaste processing. The results of the vendor audits were satisfactor One self-assessment audit was conducted by quality assurance during this inspection period. Deficiencies identified by the evaluators were properly placed in the corrective action program. The inspector noted no problems with the assessmen The inspector reviewed a summary of performance improvement requests and selected performance improvement requests relating to transportation and radioactive waste management activities. Selected corrective actions and closure documentation were reviewed and determined to be adequate. The inspector noted that corrective actions were completed in a timely manne c. Conclusions The biennial quality assurance audit of the Process Control Program was not comprehensive. The audit only addressed observation of a radwaste shipment, reviews of task observations, a summary of Performance Improvement Roquests, and regulatory commitments. The Process Control Program contained approximately 13 areas and implementing procedures for processing, packaging, and transportation of radioactive wastes. As a result, this narrowly focused audit provided management with limited information needed to assess the program's performanc V. Manaaement Meetinas X1 Exit Meeting Summary The inspectors presented the inspection results to members of licensee management at an exit meeting on August 20,1999. The licensee acknowledged the findings presente No proprietary information was identifie l I
. l
..
ATTACHMENT l SUPPLEMENTAL INFORMATION PARTIAL LIST OF PERSONS CONTACTED Licensee B. McKinney, Plant Manager S. Koenig, Manager, Performance Improvement and Assessment M. Blow, Manager, Chemistry and Radiation Protection K. Hall, Supervisor, Corrective Actions V. Cannales, Supervisor, Quality Evaluations S. Burkdoll, Supervisor, Health Physics and Chemistry Training ,
C. Medenciy, Supervisor, Health Physics Radwaste C. Stone, Quality Assurance R. Skiles, Health Physics Radwaste Instructor C. Reekie, Engineering Specialist, Licensing l
NRC )
R. Kopriva, Senior Project Engineer INSPECTION PROCEDURES USED 86750 Solid Radioactive Waste Management and Transportation of Radioactive Material
!
PARTIAL LIST OF DOCUMENTS REVIEWED Lists of Performance improvement Requests relating to the inspection areas (3/1/98 to 8/15/99)
Performance Imorovement Reauests j l
PIR-97-0737 PIR-98-0011 l PIR-98-0624 l PIR-98-0759 PIR-98-0765 PIR-98-0791 PIR-98-0939 PIR-98-1286 PIR 98-2090 PIR-98 2811 PIR 98-3327 PIR-98-3607 PIR-99-0801 '
PIR-99-0948 PIR-99-2150 PIR-99-2316
r- 1 I
O t-2-WCNOC OA Audit K-508, February 18 to March 19,1999 Self Assessment Report K-473 dated April 10,1997 Sucolier Evaluation Reoorts T105 dated September 4,1998 TB66 dated March 11,1998 SC75 dated September 3,1908 Quality Assurance Observations (Plant Evaluation Checklist) OB 98-0138, OB 98-0352, l OB 98-0445, and OB 99-0005 j l
Procedures !
AP 17C-017 " Manager Chemistry / Radiation Protection Duties and Responsibilities," i Revision 2 !
AP 20A-002 " Audit System," Revision 4 AP 20A-003 " Audit / Surveillance Scheduling," Revision 3 AP 20A-004 " Audit Procedure," Revision 4 ,
AP 20A-005 " Surveillance Procedure," Revision 3 AP 25-001 " Radiation Protection Quality Program Requirements," Revision 1 AP 28D-001 "Self 4 ssessment Process," Revision 4 AP 30D-010 " Contractor Training and Qualification," Revision 1 ;
AP 30D-100 " Health Physics Training Program," Revision 1 AP 30G-001 " Training, Qualification, and Certification of Audit Personnel," Revision 2 AP 31-001 " Packaging for Transporting Type B and Fissile Quantities of Radioactive Materials Quality Program Reouirements," Revision 1
'
AP 31 A-001 " Low Level Radioactive Waste Quality Program Requirements,"
Revision 1 AP 31 A-100 " Solid Radwaste Process Control Program," Revision 2 AP 31B-001 " Hazardous Waste Management," Revision 2 RPP 07-101 " Control of Radioactive Material Management Software and Data Bases,"
Revision 5 RPP 07-110 " Solid Radwaste Packaging," Revision 5 RPP 07-111 " Handling Cartridge Filters," Revision 7 RPP 07-120 " Preparation and Shipment of Radioactive Waste," Revision 11 RPP 07-121 " Preparation and Shipment of Radioactive Material," Revision 11 RPP 07-130 " Verification of Free Standing Water in High Integrity Containers,"
Revision 2 RPP 07-131 " Bead Resin / Activated Carbon Dewatering Procedure for CNSI 14-215 or Smaller Liners," Revision 3 RPP 07-140 " Mixed Waste Handling, inspection and Storage," Revision 4 At 02B-001 " Resin Monitoring Guidelines," Revision 1 Al 21-002 " Standards for Completion of Fundamentals Qualification Special Qualification Card," Revision 0 Al 25A-002 " Radiation Protection Interdepartmental Proi n Review," Revision 0
"
Al 28D-001 " Wolf Creek Performance Observation Prograin, Revision 3 Al 30E-005 " Instructor Training, Qualification, Certification, and Continuing Training,"
Revision 5