ML20129G828

From kanterella
Revision as of 07:07, 6 July 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Final Significant Const Deficiency Rept Re Inadequate Performance of motor-operated Valve Supplied by Anchor Darling.Initially Reported on 850315.Replacement Motor to Be Provided by Limitorque Corp
ML20129G828
Person / Time
Site: Hope Creek PSEG icon.png
Issue date: 06/24/1985
From: Martin T
Public Service Enterprise Group
To: Murley T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
NUDOCS 8507180292
Download: ML20129G828 (2)


Text

R F

, e '*

Public Service Electric and Gas Company Thomes J. Martin 80 Park Plaza, Newark, NJ 07101 201-430-8316 Mailing Address: P.O. Box 570, Newark, NJ 07101 Vice President Engineering and Construction June 24, 1985 Dr. Thomas E. Murley, Administrator U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement Region I 631 Park Avenue King of Prussia, Pennsylvania 19406

Dear Dr. Murley:

SIGNIFICANT CONSTRUCTION DEFICIENCY MOTOR OPERATED VALVE - HPCI HOPE CREEK GENERATING STATION On March 15, 1985, a verbal report was made to Region I, Office of Inspection and Enforcement representative, Mr. J.

Strosnider, advising of a significant construction deficiency regarding the performance of a motor operated valve supplied by Anchor Darling. On April 15, 1985, an interim report describing the deficiency and conveying our safety analysis was submitted to your office. The following final report is provided in accordance with 10CFR50.55 (e) .

As indicated in our report dated April 15, 1985, Bechtel initiated a factory data review to ensure that the problem is isolated to the subject valve. Bechtel has advised us that no additional discrepancies were found as a result of this review.

Bechtel has issued Purchase Order No. 10855-F-61639 (Q)-SU to Limitorque Corporation to provide a replacement motor that is compatible with existing circuitry. Delivery of the motor is 8507180292 850624 PDR ADOCM 05000354 S PDR' N

p --

a l*

Dr. T. E. Murley 2 6/24/85 scheduled for the week of July 22, 1985. Subsequent installa-tion records will be available for review by your Resident Inspector.

Very truly yours,

/

C Office of Inspection and Enforcement Division of Reactor Construction Inspection Washington, D. C. 20555 NRC Resident Inspector - Hope Creek P. O. Box 241-Hancocks Bridge, NJ 08038 Records Center Institute of Nuclear Power Operations 1100 Circle 75 Parkway, Suite 1500 Atlanta, GA 30339

!