 Issue dateTitleTopic
ML20217M02120 September 1999Part 21 Rept Re Possible Deviation of NLI Dc Power Supply Over Voltage Protection Circuit Actuation.Caused by Electrical Circuit Conditions Unique to Remote Engine Panel. Travelled to Hope Creek to Witness Startup Sequence of DG
ML18107A3441 June 1999Interim Part 21 Rept Re Premature Over Voltage Protection Actuation in Circuit Specific Application in Dc Power Supply.Testing & Evaluation Activities Will Be Completed on 990716
ML18106B09325 February 1999Part 21 Rept Re Possible Defect in Swagelok Pipe Fitting Tee,Part Number SS-6-T.Caused by Crack Due to Improper Location of Heated Bar.Only One Part Out of 7396 Pieces in Forging Lot Was Found to Be Cracked.Affected Util,Notified
ML18106B0551 February 1999Part 21 Rept Re Possible Matl Defect in Swagelok Pipe Fitting Tee,Part Number SS-6-T.Defect Is Crack in Center of Forging.Analysis of Part Is Continuing & Further Details Will Be Provided IAW Ncr Timetables.Drawing of Part,Encl
ML18106B04429 January 1999Part 21 Rept Re Possible Defect in Swagelok Pipe Fitting Tee Part Number SS-6-T.Caused by Crack in Center of Forging. Continuing Analysis of Part & Will Provide Details in Acoordance with NRC Timetables
ML20202F68626 January 1999Engine Sys,Inc Part 21 (10CFR21-0078) Rept Re Degradation of Synchrostat Model ESSB-4AT Speed Switches Resulting in Heat Related Damage to Power Supply Card Components.Caused by Incorrect Sized Resistor.Notification Sent to CustomersReverse polarity
ML17354B0979 September 1998Part 21 Rept Re Possible Machining Defect in Certain One Inch Stainless Steel Swagelok Front Ferrules,Part Number SS-1613-1.Caused by Tubing Slipping Out of Fitting at Three Times Working Pressure of Tubing.Notified Affected Utils
ML20236N6759 July 1998Part 21 & Deficiency Rept Re Notification of Potential Safety Hazard from Breakage of Cast Iron Suction Heads in Apkd Type Pumps.Caused by Migration of Suction Head Journal Sleeve Along Lower End of Pump Shaft.Will Inspect Pumps
ML20217D57020 March 1998Part 21 Rept 40 Re Governor Valve Stems Made of Inconel 718 Matl Which Caused Loss of Governor Control.Control Problems Have Been Traced to Valve Stems Mfg by Bw/Ip.Id of Carbon Spacer Should Be Increased to at Least .5005/.5010
ML20210E35927 March 1997Part 21 Rept Re Sorrento Electronics Inc Has Determined Operation & Maint Manual May Not Adequately Define Requirements for Performing Periodic Surveillance of SR Applications.Caused by Hardware Failures.Revised RM-23A
ML20096A40228 December 1995Interim Part 21 Rept Failure of Scram Discharge Vol Drain Valve 1BFHV-F011.Possible Causes of Failure,Includes Spring mis-adjustment,change in Spring Adjuster Setting & Spring Relaxation.Further Investigation OngoingScram Discharge Volume
ML20082S74026 April 1995Part 21 Rept Re Hinge Arms Associated W/Sixteen Swing Check Valves Mfg by Anchor-Darling Valve CoAnchor Darling
ML20081L77029 March 1995Initial Part 21 Rept Re Anchor-Darling Check Valve Hinge Arms.Cs Pump B Discharge Check Valve Failed to Close in Nov 1994 Because Butt Stop on Hinge Arm Not of Sufficient Length.New Butt Stop Hinge Arm,Hinge Pin & Disc Installed
ML20063M1702 March 1994Part 21 Rept Clarifying & Supplementing Info Provided by Licensee Re Deficiency in Qualified Life Calculation for Microswitches Mfg by Comsip,Inc. Subj PTW-5300 Dc Indicators Supplied by Comsip,Inc,Mfg by Microswitch Corp
ML20046C6595 August 1993Part 21 Rept:On 930429,deficiency Identified Re Heat Damage to Comsip Series PTW-5300 Dc Powered Microswitches.Initially Reported on 930709.Safety-related Dc Microswitches Will Be Replaced Prior to 931230
ML20128H9939 February 1993Interim Deficiency Rept Re Defect in Replacement EDG Fuel Oil Pumps Supplied by Colt Industries (Fairbanks Morse Engine Div).Initially Reported on 930111.Plugs & O-rings Repositioned.Vendor Requested to Perform EvaluationSafe Shutdown
ML18096B2421 February 1993Part 21 Rept Re Possible Matl Defect in Stainless Steel Swagelock Tube Fittings.Initially Reported on 921218.List of Part Numbers,Heat Codes & Addl Affected Customers Encl
ML20127K8816 January 1993Part 21 Rept Re Engine Driven Fuel Oil Pump Being Returned for Proper Configuration Due to Portion of O Ring Missing from Plug
ML20116L43120 October 1992Followup to Part 21 Rept from Consolidating Power Supply, Inc Re Purchase & Procurement of 24-inch Flange at Facility Which Failed to Meet ASME Code Class III Requirements.Flange Purchased by Conex Pipe Sys,Inc.Investigation Underway
ML20101L07929 June 1992Final Part 21 Rept Re Defect in Assembly Process for Gh Bettis Containment Atmosphere Control Sys Valve Replacement Actuators.Initially Reported on 920529.Air Filter Installed in Compressor Main Air Line to Prevent ContaminationLoctite
ML20102B20724 June 1992Part 21 Rept Re Cracking of Stellite 21 Hardfacing on Guide Nose of Poppets Supplied as Part of MSIV Leakage Improvement Mod.Initially Reported by Clei on 920522. Recommends That Liquid Penetrant Exam Be PerformedLiquid penetrant
ML20097D9113 June 1992Part 21 Rept Re Design Defect in Degraded Grid Trip & Bus Transfer Scheme for Class IE Vital Busses Supplied by Bechtel Power Corp.Initially Reported on 920508.Design Change Package 4EC-3341 Issued & Implemented
ML20097H15829 May 1992Initial Part 21 Rept Re Failure of Gh Bettis Actuators Used at Plant.Gh Bettis Has Ordered Replacement SOVs & Pilot Valves for Installation at Butterfly Valve Mfg,C&S Valve
ML20102B1048 May 1992Part 21 Rept Re Defect Discovered in Degraded Grid Trip/Bus Transfer Scheme for Class IE Vital Bus Equipment.Time Delay of .7 Incorporated in Loading Scheme to Allow Loads to Drop Off of auto-swapped Class IE Buses
ML20077N3499 August 1991Part 21 Rept Re Potential for Malfunction of Filtration Recirculator Ventilation Sys Heater Control Panels at Plant Due to Excessive Heat Rise.Heater Control Panel Doors Removed
ML20077J96430 July 1991Interim Deficiency Rept Re Potential Deviation of Design Safety Function of Filtration Recirculator Ventilation Sys Heaters Controls Panels.Further Investigation Required to Determine If Defect Requires Notification,Per 10CFR21
ML19332C58320 November 1989Part 21 Rept Re Misapplication of Magnetrol Level Switches Supplied by GE W/Hpci & RCIC Turbine Assemblies.Switches Declared Inoperable & Electrically Disconnected.Magnetrol Will Modify Spare Level Switch Assemblies
ML20205F32110 October 1988Part 21 Rept Re Potential Deviation from Tech Spec Concerning Ry Indicators Due to Operating Temp Effect on Analog Meter Movement.Initially Reported on 881006.Customers Verbally Notified on 881006-07
ML20215G24416 June 1987Part 21 Rept Re Failure of Load Sequencing Equipment Supplied in Aug 1977 During Scheduled Testing.Caused by Open Electrical Connection on One Crimp Lug.Since 1978,insulated Lugs Used on All Equipment
ML20211P72123 February 1987Part 21 Rept Re Rockbestos Coaxial Cable Used in Sorrento Electronics Digital & Analog high-range Radiation Monitor. Insulation Resistance at High Temp Not High Enough for Ion Chamber & Associated Electronics to Operate Properly
ML20210S3354 February 1987Part 21 Rept Re Cracking in O-ring on Latch Mechanism on Contactors in Nuclear Exciters.Initially Reported on 861216. Sprecher & Schuh Changed O-ring Matl to Viton E60C. Contactors Will Be Returned to Vendor & Rebuilt
ML20214E92328 January 1987Part 21 Rept Re Incorrect Valve Stem Matl on Dragon Valves. Evaluation Underway.Owners or Architects/Engineers & NRC Will Be Notified of Results of Evaluation & Recommendations
ML20215B96826 September 1986Part 21 & Deficiency Rept Re Synchro-Start Type Essb Speed Switches.Initially Reported on 860822.Speed Switches Currently in Svc or Designated for Svc Will Be Tested for Relay Contact Closure & Relay Contact Condition
ML20212N13725 August 1986Part 21 Rept Re Potentially Defective Operation of Synchro-Start Products,Inc Synchronizing Speed Switches Used in Auxiliary Generating Equipment.Initally Reported on 860820.Next Rept Will Be Submitted by 860926
ML20211C6189 June 1986Part 21 Rept Re Unknown Qualification of Yokogawa Type AB 40 Voltmeters & Ammeters Due to Unreported Design & Configuration Changes.Three Nuclear Plants Receiving 23 Items as Class 1E Spare Parts Notified.List of Users Encl
ML20141E4361 April 1986Final Significant Const Deficiency Rept Re Failure of Electrical Amplifier Assembly in Tobar Transmitters to Function During Irradiation Testing.Initially Reported on 860303.Seven Transmitters Will Be Replaced
ML20141E4411 April 1986Final Significant Const Deficiency Rept Re Anchor-Darling Testable Check Valves Not Opening/Closing Under Normal Operating Conditions.Initially Reported on 860305.Valves Modified to Improve Mechanism for Opening/Closing Disc
ML20140J42631 March 1986Part 21 Rept Re Nuclear Valves Shipped to Pse&G.Internal Parts Lapped Which Could Reduce or Eliminate Nickel Plating Resulting in Seat Leakage & Shifting Problems
ML20210E00317 March 1986Part 21 Rept Re Failure of Amplifiers at Hope Creek Plant During Gamma Radiation Testing.Initially Reported on 860314. Util Supplied W/List of Model 32 Transmitters Which Meet Criteria
ML20199E9167 March 1986Final Significant Const Deficiency Rept Re Overspeed Trip on Emergency Diesel Generator Mfg by Colt Industries.Initially Reported on 860213.All Colt-Pielstick PC-2 Engines Will Be Modified by 860415Safe Shutdown
ML20141N6505 March 1986Final Deficiency Rept Re Environ Qualification of Tobar Pressure Transmitter Terminations.Initially Reported on 860205.Pressure Transmitters Reworked & Discrepancy & Startup Deviation Repts Issued
ML20154H2193 March 1986Part 21 & Deficiency Rept Re Tobar Model 32-2 Transmitters W/Steel,Not Polyester or Aluminum Amplifier Housings. Initially Reported on 860227.Preliminary Investigation Confirms Adequacy of Transmitters
ML20141N70126 February 1986Suppl to Final Significant Const Deficiency Rept Re Anchor/Darling Swing Check Valves.Eight Valves W/O Lock Welds Reworked
ML20151Y8144 February 1986Part 21 Rept Re Colt-Pielstick Engine Tripping Out on High Speed When Started for Test Purposes at Seabrook.Caused by Source of Air Pressure Staying On.Engines Will Be Modified to Positively Vent Air from Rack Boost CylinderSafe Shutdown
Boric Acid
Shutdown Margin
Packing leak
High Radiation Area
Ultimate heat sink
Fire Barrier
Anticipated operational occurrence
Hydrostatic
Probabilistic Risk Assessment
Operating Basis Earthquake
Design basis earthquake
Process Control Program
Fuel cladding
Pressure Boundary Leakage
Grace period
Power change
Unidentified leakage
ML20137U8463 February 1986Significant Const Deficiency Rept Re Inadequate Power to Tobar Pressure Transmitters.Initially Reported on 860115. Design Change Package (DCP-7153) Issued to Modify Power Supply Circuits
ML20140A52819 December 1985Part 21 Rept Forwarding Ltr Sent to Customers Re Check Valves Missing Lock Welds on Hinge Supports or Hinge Support Capscrews,Per 851121 Request.List of Customers Receiving Ltr Also Encl
ML20137Z16121 November 1985Final Part 21 & Significant Deficiency Rept Re Ruskin Mfg Co Spring Closure Fire Dampers.Initially Reported on 841224. Dampers Reworked & in-place Testing Program to Identify Limiting Airflow Conditions ImplementedFire Barrier
Exemption Request
ML20137S1036 November 1985Final Part 21 & Significant Const Deficiency Rept Re Heat Buildup Inside Generator Control Cabinets.Initially Reported on 850403.Design Change Packages 570 & 7079 Implemented. Current Transformers Replaced
ML20138K27311 October 1985Final Part 21 & Const Deficiency Rept Re Missing Lock Welds on Anchor/Darling Swing Check Valves.Initially Reported on 850911.Set Screws Staked During Insp & Disc Nut Pins Peened as Alternative to Lock Welding
ML20133N82110 October 1985Final Const Deficiency Rept Re Misoperation of Bailey Controls Co 862 Sys Logic Module Logic Memories During Environ Qualification Testing.Initially Reported on 850909. Gap in Circuit Board Pads Increased & Area Cleaned