ML20140J426

From kanterella
Jump to navigation Jump to search
Part 21 Rept Re Nuclear Valves Shipped to Pse&G.Internal Parts Lapped Which Could Reduce or Eliminate Nickel Plating Resulting in Seat Leakage & Shifting Problems
ML20140J426
Person / Time
Site: Salem, Hope Creek, 05000000
Issue date: 03/31/1986
From: Naumann H
AUTOMATIC SWITCH CO.
To: Zech G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
REF-PT21-86, REF-PT21-86-124-000 PT21-86-124, PT21-86-124-000, NUDOCS 8604040328
Download: ML20140J426 (1)


Text

g Automa.ic Switca Co.

= =.

Since 'd88 FLORH AM PARK. NEW JERSEY 07332

  • N J 1201) 966-2000 /N Y 1212)344 37 6 March 31, 1986 9

St(

U.S. Nuclear Regulatory Commission 4 Q l

Office of Inspection & Enforcement

/

Washington, DC 20555 Attention:

Mr. Gary C. Zech Chief, Vendor Program Branch

Subject:

Nuclear Valves 125/DC ASCO Catalog No. NPK8342B4E, Serial Nos. 86157N1-20 Customer - Public Service Electric & Gas Co.

Gentlemen:

During the processing of the order for the 20 referenced valves',,

certain internal parts were lapped in order to reduce seat leakage.

This lapping reduced or eliminated nickcl plating in certain areas which could lead to greater than allowable seat leakage and shifting problems before the valves reach their qualified life.

Although the valves were shipped to Public Service Electric & Gas Company, they are as yet to be installed, and we have requested their return to ASCO for examination and rebuilding as applicable.

Based on the information that we have obtained, the referenced valves are the only ones which have been subjected to this lapping procedure in this manner, and thus, the only ones which are being recalled.

Very truly yours, AUTOMATIC SWITC11 COMPANY

[,do-m~

8604040320 060331 A

PDR ADOCK 050 2

es e S

Ilans R.E. Naumann President and Chief Operating Officer IIREN:mw cc:

W. Brown D. llolland J. Mikesell L. Olsen J. Shank 8

D. Vollmer Public Service Electric & Gas Co.

(P.O.#939563)

\\ %

,