I,~

FRED A. LENNON CHAIRMAN CRAWFORD FITTING COMPANY SOLON, OHIO 44139 February 1, 1993 Document Control Desk Off ice of Nuclear Reactor Regulation Nuclear Regulatory Commission Washington, DC 20555

Subject:

Defects Potentially Reportable under 10CFR21

Dear Sir:

PHONE (216) 248-4600 FAX (216) 349-5970 Pursuant to our letter of December 18, 1992 on a possible material defect in stainless steel Swagelok tube fittings, we are writing this follow-up to report some additional certifications of the parts to nuclear facilities.

A list of the part numbers, heat codes and the nuclear customers to which these additional fittings have been sold is enclosed.

Please note~ this is not the reporting of any new heat codes with a possible defect.

These are additional f acil'ities which our search has uncovered on the previously report:ed heats.

All these facilities have already been notified by us of this potential problem.

If you have any questions, please do not hesitate to contact us.

E.

y 4-

~ahuranec Vice "President and General Manager cc:

SM

.. EPM

  • cc' -

EDS- >-. :*.

c... _.

.. :**~---**~*~:

~::

.~**-.-_ -

.'.1

-~

~ '. '

,.I

~-.....

. t SS-400-3 (EON)

PG & E Company 90 Miles N.W. of Avila Beach Avila Beach, CA 93424 P.O. #057250 SS-600-2-4 (EON)

Nebraska Public Power District Cooper Nuclear Station Brownville, NE 68321 P.O. 353610 SS-600-2-4 (EON)

Omaha Public Power District

-Ft. Calhoun Station Ft. Calhoun N.E. 68023 P.O. S073817 SS-600-2-4 (EDK)

PSE & G Co.

Nuclear Department Material Center Artificial Island End of Buttonwood Road Hancocks Bridge, NJ 08038 P.O. 404006 Rel. 039 SS-600-2-6 (EPY)

Cooper Industries, Inc.

Energy Services Group 150 Lincoln Avenue Grove City, PA 16127 P.O. #3621 N 1998 SS-600-2-6 (EPY)

Nebraska Public Power Station Cooper Nuclear Station BroW'nvilJ.. e NE 68321 P.O.* 356167 SS-600-2-6 (EPY)

PSE & G Nuclear Dept. Material Center Artificial Island End of Buttonwood Road Hancocks Bridge, NJ 08038 P.O. 404005 Rel 008 109 pcs.

10 pcs.

100 pcs.

20 pcs.

80 pcs.

10 pcs.

6 pcs.

40 pcs.