ML20101L578

From kanterella
Revision as of 18:37, 28 April 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Interim Potentially Reportable Deficiency Rept 180 Re Failure to Maintain Adequate Document Control of Vendor Manuals.Initially Reported on 840918.Next Rept Will Be Submitted by 850116
ML20101L578
Person / Time
Site: Waterford Entergy icon.png
Issue date: 12/19/1984
From: Cook K
LOUISIANA POWER & LIGHT CO.
To: Martin R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
180, WP384-3472, NUDOCS 8501020279
Download: ML20101L578 (1)


Text

Louisiana / ,4.o -c~o.-e.7 9 .o .ex.co.

P O W E R & L I G H T / N W CALEANS LoUSANA 7o1744CoS 9 (So4)388-.345 MIDDLE SOUTH mim sss w December 19, 1984 3P84-3472 Q-3-A35.07 3-A1.01.04 A4.05 Mr. R. D. Martin Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 .a T

Arlington, TX 76011

Dear Mr. Martin:

d

Subject:

Waterford 3 SES Docket No. 50-382 Potentially Reportable Deficiency No. 180

" Failure to Maintain Adequate Document Control of Vendor Manuals"

References:

1. W3P84-3221 from K.W. Cook (LP&L) to J.T. Collins (NRC),

dated 11/16/84

2. W3P84-2386 from K.W. Cook (LP&L) to J.T. Collins (NRC),

9 dated 9/13/84 In accordance with 10CFR50.55(e), LP&L provided telephone notification on September 18, 1984 of the subject deficiency. Via Reference 1, LP&L obtained an extension to December 17, 1984 for submittal of the written report on PRD-180 The Reference 2 letter provided LP&L's response to related Violation No. 8425-01 which provided details on corrective actions planned and underway to resolve this violation.

LP&L requiros additional time to evaluate the safety significance of PRD-180 for reportability determination of the deficiency per 10CFR50.55(e) guidance. LP&L has, therefore, rescheduled the submittal of the written report on PRD-180 for January 16, 1985.

If you have any questions, please contact Mr. G. E. Wuller at (504) 464-3499, Onsite Licensing.

Yours very truly, K.W. Cook Nuclear Support & Licensing Manager KWC:GEW:sms cc: NRC, Director, Office of I&E INPO Records Center G.W. Knighton, NRC-NRR (Attn: D.L. Gillispie)

J.H. Wilson, NRC-NRR E.L. Blake NRC Resident Inspectors Office W.M. Stevenson 8501020279 841219 - gg gDRADOCK05000