Revised Hope Creek Generating Station Event Classification Guide,Including Rev 33 to Table of Contents,Rev 12 to Attachment 1,Page 5 & Rev 7 to Attachment 2,Page 4
ML20069N207
Person / Time
Site: Hope Creek PSEG icon.png
Issue date: 06/09/1994
From:
Public Service Enterprise Group
To:
References
PROC-940609, NUDOCS 9406220293
Download: ML20069N207 (4)


Text

-

PUBLIC SERVICE ELECTRIC & GAS COMPANY 06/09/94' DOCUMENT DISTRIBUTION MOTICE PAGE 1 OF 1 TRANSMITTAL: DDG 0373826 TO: NUCLEAR REGULATORY COMMISSION I DOCUMENT CONTROL DESK COPYHOLDER: HECG0065 WASHINGTON, DC 20555 DESCRIPTION: TGC CORRECTED PAGE IIECG PLEASE INSERT Tile FOLLOWING DOCUMENTS INTO YOUR CONTROLLED FILE / MANUAL.

SUPERCEDED DOCUMENTS MUST BE SO MARKED AND PHYSICALLY REMOVED OR DESTROYED.

Silt /

, CLASS DOCUMENT ID VOL INST REV STAT TYPE FORMAT OTY PROC ATT. 01 000 012 A IIECG II 001 PROC ATT. 02 000 007 A HECG H 001 oic , . ~

f

/OVE 4 A L .. i

((s PLEASE SIGN AND DATE THIS NOTICE TO ACKNOWLEDGE RECEIPT  !

AND RETURN WITiiIN 5 WORKING DAYS TO:

PSE&G DDG/MC N04 PO BOX 236 IIANCOCKS BRIDGE, NJ 08038 TO CilANGE YOUR DISTRIBUTION S'inTUS, PLEASE CliECK Tile APPROPfd ATE SPACE BELOW:

REMOVE FROM DISTRIBUTION CHANGE COPYHOLDER INFOHkATION SEE MY INSTRUCTIONS ABOVP COP OLDER SIGNATURE: bbCk bbh(354 _ DATE:

PDR DDG USE ONLY: DATA ENTRY COMPLETED:

l

. ~ i

i

, HOPE CREEK GENERATING STATION EVENT CLASSIFICATION GUIDE CHANGE PAGES FOR REVISION #33 The Table of Contents forms a general guide to the current revision ,.

of the Hope Creek ECG. The' changes.that are made in this TOC Revision #33 are shown below. Please check that your revision ,

packet is complete and remove the outdated material listed below: ,

ADD REMOVE Page Description Rev. Page Description Rev.

5 of 16 Att. 1 12 5 of 16 Att. 1 12 thru thru 5 of 16 5 of 16 4 of 7 Att. 2 7 4 of 7 Att. 2 7 thru thru l 4 of 7 4 of 7 O NOTE: PLEASE INLERT (ADD) CORRECTED PAGE AND DISCARD (REMOVE)

INCORRECT PAGE - DUE TO TYPOGRAPHICAL ERROR ,

1 1

I 1

l HC-ECG 1 of 1

EC3

+

ATT 1 Pg. 5 of 16 O Initials NOTE SSCL shall be transmitted every 30 minutes or immediately if a significant' change in station status occurs.

3. Upon receipt of the Station Status checklist EC (SSCL) from the (CM2), review and approve for transmittal.
4. Ensure the completion and approval of the NRC Data EC Sheet form.
a. Obtain the form (both pages) from'the CM2 (Att. 8)
b. Provide the approved form to the CM2 for transmittal to the NRC as soon cs possible, but not to exceed ONE HOUR.

NOTE:

() As manpower permits, the Emergency Coordinator may assign an additional communicator (preferably an RO or SRO) to provide continuous updates to the NRC. The assignment of an additional communicator should not be made if personnel being considered are required to mitigate the event or to complete high priority. Emergency Response functions ~.

c. Notify the NRC of any significant changes in Plant Status, Emergency Status, or any actions taken in accordance with 10CFR50.54(x).
d. Direct CM2 to log or document (via NRC Data sheet) any additional information provided to the NRC.

This includes, but is not limited to, changes in Plant Status, Emergency Status, or any actions taken in accordance with 10CFR50.54(x).

5. If relieved as EC prior to termination of the Unusual EC Event, document the name of your relief below, assumed EC duties at hrs.

s Name time HCGS Rev. 12

. _. _ _ _ ~~ _ _. __

i 3C3

  • ~

ATT'2 'l Pg.-4 of 7 l EC Log Sheet (Cont.)

Initials NOTE:

As manpower permits, the' Emergency Coord.inator may assign an additional communicator (preferably an RO or SRO) to provide continuous updates to the NRC. The assignment of an additional communicator should not be made if personnel being considered are required to mitigate the event or to complete high priority Emergency Response functions.

l c) Notify the NRC of any significant changes in Plant Status, Emergency Status, or any actions taken in accordance with 10CFR50.54(x). t d) Direct CM2 to log or document (via NRC Data Sheet) any additional information provided to the NRC.

O. This includes, but is not limited to, changes in Plant Status, Emergency Status, or any actions taken

+

in accordance with 10CFR50.54(x). ,

3. When turning over EC duties ensure your communicators EC are directed to turnover notifications responsibilities to the facility being activated.  ;

G. EMERGENCY ESCALATION [

EC 11 the event classification escalates above an ALERT, then exit this attachment and implement a new attachment as directed by the classifying section EAL.

Escalated to (circle one) SAE -

GE H. RELIEF / TURNOVER EC If relieved as EC prior to termination of the ALERT, then j turnover responsibility for this attachment to the oncoming  ;

EC and document your relief below and in EPIP 102H. j assumed EC duties at hrs. f name time c i

O HCGS Rev. 7 L

, __ - _