SPEC 2AL TEST EXCEPT2ONS 3/4.10.8 INSERVICE LEAK AND HYDROSTATIC TESTING LIMITING CONDITION FOR OPERATION l

3.10.8 When conducting inservice leak or hydrostatic testing, the average reactor coolant temperature specified in Table 1.2 for OPERATIONAL CONDITION 4 I

may be increased to 212'F, and operation considered not to be in OPERATIONAL j

CONDITION 3, tc, allow performance of an inservice leak or hydrostatic test provided the following OPERATIONAL CONDITION 3 LCO's are mots j

a.

3.3.2, " ISOLATION ACTUATION INSTRUMENTATION", Functions 2.a, 2.b, l

2.c, 2.d and 2.e of Table 3.3.2-1; l

b.

3.6.5.1, "SECOI;DARY CONTAINMENT INTEGRITY";

l l

c.

3.6.5.2, " SECONDARY CONTAINMI T AUTOMATIC ISOLATION DAMPERS *; and d.

3.6.5.3, " FILTRATION, RECIRCULATION AND VENTILATION SYSTEM."

l APPLICABILITY:

OPERATIONAL CONDITION 4, with average reactor coolant temperature > 200*F.

ACTION:

With the requirements of the above specification not satisfied, immediately l

enter the applicable condition of the affected specification or immediately l

suspend activities that could increase the average reactor coolant temperature or pressure and reduce the average reactor coolant temperature to n 200*F within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

SURVEILLANCE REQUIREMENTS 4.10.8 verify applicable OPERATIONAL CONDITION 3 surveillance for specifications listed in 3.10.8 are met.

i 9805220194 980513 PDR ADOCK 05000354 P

PDR HOPE CREEK 3/4 10-8 Amendment No. 69

>