3/4.6 CONTAINMENT SYSTEMS i

1' 3/4.6.I PRIMARY CONTAINMENT f) b PRIMARY CONTAINMENT INTEGRITY

_ LIMITING CONDITION FOR OPERATION PRIMkRY CONTAINMENT UfIf,GRITY shall be maintained

3. 6.1.1 ApPLICABT'.ITY:

OPERATIONAL CONDITIONS 1, 28 and 3.

ACTION:

~

within I hour or be in at least HOT SHUTDOW COLD SHUTOOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

I i

SURVEILLANCE REQUIREMENTS

  • i I

4.6.1.1

_=

PRIMARY CONTAINNENT INTEGRITY shall be demonst After each closing of each penetration sub a.

except the primary containment air locks, ject to Type 8 testing, m.r r,

if opened following Type A In oce.c4xce_

_ or 8 test, by leak rate tetting.th: = !:

t fth : :t ^:, '* 1 ;';,

; r v r; init f:: th:

deterr! 01 pur u; t te S r :!'?::::::

wA h

%c.f eftd t^ t'e -le ?- : :*^

t.

f:-

cog.g.,A t.e b y,

8^^e'~~:-t '. ".1. ?_ d '-

!' e" Tre * =d C p:::tr:tf:::, th:

g p,

_ g u e..a i..u.7 --+;

4.

7...

w z..:! *: G,6Gh b.

At least once penetrations **per 31 days by verifying that all primary containment not capable of being closed by.0PERABLE containment automatic isolation valves and required to be closed during accide conditions are closed by valves, blind flanges, or deactivated 3.6.3-1 of Specification 3.6.3. automatic valves secured in po By verifying each primary containment air lock is in compliance w c.

the requirements of Specification 3.6.1.3.

d.

By verifying the suppression chamber is in compliance with the requirements of Specification 3.6.2.1.

4 "See Speciel Test Exception 3.10.1

    • Except valves, blind flanges, and deactivated a re located in the closed positi6n.

each COLD SNUTOOWN except such verification need not

  • Q primary containment has not been de-inerted since the last verification or more cften than once per 92 days.

HOPE CREEK 3/4 6-1

's 9704090006 970401 PDR ADOCK 050003S4 p

POR

j~.O J CONTAINMENT SYSTEMS l

PRIMARY CONTAINMENT LEAKAGE LIMITING CONDITION FOR OPERATION

3. 6.1. 2 Primary containment 1eakaae rates shall be limited to:

An overall integrated leakage r N [ir pn M h = ; ;t!N:I th a.

_ rg5EP{.

nt by.;;fght Of th: ::nt:{-,nt ;

, d1 A combined leakage rate h 1r: *"n er ;r! t Ia ** * ***

b.

0.50 L for all

&PdQ.4 penetrations and all valves listed in Table 3.6.3-I, ex2ept for main C * ^b.

P,.k.. p,osy steam line isolation valves *, valves which form the boundary for the long-term seal of the feedwater lines, and other valves which are i

hydrostatically tested per Table 3.6.3-1, subject to Type 8 and C tests,2:n ;rrrrf ud te P,,

".1 p:f;.

}

c.

"Less than or equal to 46.0 scfh combined through all four main steam lines when tested at 5 psig (seal system AP).

1 d.

A combined leakage rate of less than or equal to 10 gpm for all con-tainment isolation valves which form the boundary for the long-term seal

~

of the feedwater ifnes in Table 3.6.3-1, when tested at 1.10 Pa, 52.9 pr A combis.ed leakage rate of less than or equal to 10 gpm for all other e.

penetrations and containment isolation valves in hydrostatically tested lines in Table 3.6.3-1 which penetrate the primary contain-ment, when tested at 1.10 Pa, 52.9 psig Ap.

l APPLICABILITY: When PRIMARY CONTAINMENT INTEGRITY is required per Specification 3.6.1.1.

i ACTION:

.~-

With:

The measured overall inte

=adin; 0.-?5 L, r des + grated primary containment leakage rate (r pe A a.

y

)n.+ y o r-A b.

The measured combined leakage rate for all penetratio6s and all valves listed in Table 3.6.3-1, except for main steam line isolation valves", valves which form the boundary for the long-term seal of the feedwater lines, and other valves which are hydrostatically tested per Table 3.6.3-1, subject to Type 8 and C tests [ q:rd"; 0.50 L,, or The measured leakage rate e.xceeding 46.0 scfh combined through all c.

four main steam lines, or d.

The measured combined leakage rate for all centainment isolation valves which form the boundary for the long-term seal of the feedwater lines in Tabla 3.6.3 1 exceeding 10 gpm, or The measured combined leakage rate for all other penetrations and e.

containment isolation valves in hydrostatically tested lines in Table 3.6.3-1 which penetrate the primary containment exceeding 10 gpm, ggggg/

restore:

a.

The overall integrated leakage rate (s) +^ 'r: tt: r :;_:1 t: 0. 5 L,. r d ond

  • Exemption to Appendix."J" of 10 CFR 50.

HOPE CREEK 3/4 6-2 Amendment No. 32

C CONTAINNENT SYSTEMS

_ LIMITING' CONDITION FOR OPERATION (Continued) a

(

ACTION (Continued) b.

The combined leakage rate for all penetrations and all valves listec in Table 3.6.3-1, except for rnain steam line isolation valves", valves which form the boundary for the long-term seal of the feedwater lines, arc other valves which are hy#rostatically tested per Table 3.6 3-1, sucject to Type 8 and C tests to M ir thea e*e' to 0.50 L, and i

s a

The leakage rate to less than or equal to 46,0 scfh combined througn c.

m utork L 511 four main steam lines, and Wah the Pr Codcomenbg d.

The combined leakage rate for all containment isolation valves wnicn f rm the bnundary for the long-term seal of the feedwater lines in Table 3.5.3-;

RAleTe5 Prc34rn to less than or equal to 10 gpa, and The combined leakage rate for all other penetrations and containment isolation valves in hydrostatically tested lines in Table 3.6.3-1 which penetrate the primary containment to less than or equal,to 10 gpm,.

prior to increasin~g reactor coolant system temperature above 200*F.

1 SURVEILLANCE REQUIREMENTS.

j 1

4.6.1,2IThe primary containment leakage rates shall be demonstrated a-t-ee

/

'ellowing +est schedu!e and sha!' be determined da cenfere:n:: uf" t-he criteri:

erci4ted fa fapendix J ^f 10 CF" 50 u:ing th: ::th d: :nd prowition; cf ANSI l-Pc A led

5. * - 1972: for the fe lice 3-2- /N a.

00 Typ:

  • Overe!' !ntegr:ted CC-*:i e:nt L::k g ht t::t:-sh !'

1 C MS

'")

b: corducted at A0

  • 10 ?: nth 'nte-

':" dur'ng-:hutd wn at air lo cks 1

40.1 p;ig, during :::h 10 y;;r ;;rvice p;ri;d.

'he third t :: ;f-i each : t :h:!'.b: conducted dur ng th: :hutdcea for the 10 ye:r p12n:

i tac 0rvic: # sper_tf e%

e f :ny ;;ri:di Typ: ? t :t f fl; t: :::t 0.75 L,, th: tc:t :chedu!:

b.7 +for :tb::quent Type ^ te:t:

g

h:!' be revf = d and taproved by the g

C =f::1er I' tee sense:Utive Type ^ tests faf' te *eet 0.75 L,,

e j

Iype test :h:!' be p rfereed at !:::4-4v:ry IS =09th: unti' tee---

i a

-Gensecutive Type a test! meet 0. " L,.

et "ich +4*e 'na ebwa +"+

44he4M4: ?:y be refu?:d.

c.

'h: :::ur: y Of :::b Type ^ to:t th:l' b: ver'#itd by : Su?p!: rental i

te:t which:

COnfin: th: :::ur: y Of'th: test by.:rifying th:t the differ:rtet l

betee r the tupp!:rente! dat: and the Type 8 test det: 1: "ith'a

.n

  • l t

v.

.t g.

" Exemption to Appendix "J" of 10 CFR 50.

  • EThe-eaximum_pami!s ib!: test 'Sterv:1 fe th: ::::nd Typ:

^ t::t of th: fir:t-ten-yeae semice perled is extended te 55 eenth!. Tht: exten:1en expires upea jj

-completion-of-the-sesend Type te:t of the f.!r:t ten year-service ceriod.

a

}

^

HOPE CREEK 3/46-3 Amendment No. 48

CONTAINMENT SYSTEMS 0

e t

SURVEILLANCE REQUIREMENTS (Continued)

-3.

u.g ggy;g{,a Sgypygjggg gg ggg337 f;p ;;;gy;g;7y gg; ;p,;3 gn

'eekag: r:te between th: Type t::t :nd th: :epp!:::nt:1-+es4, a

2.

'Jequ i r:: the qu2ntity Of g:: 'nj: 4ee-&nte - th conta4mnent-om b!cd

    • c-the ceatria ent dur ng th: cupp!:::nte! te:t t; be-i n. w, e..
4.. s w p.

.a ee 1.......

ww.-..

v m

'h:,formu : to u ed 15:

[L

~L

- n 25 L 1a' L

l

< ri

+e o

am C

-o am 0.25 L,' wh::: L 2 2"EE 220^#

U 'o 2 2'ECI *E000d 02 2N c

..s

,..u

.. A

,..y.

ooo m,

d.

Tjpe.2 ond C teekt :h;I' b; : ndu:t^d with g:: et ",, "0.1 psig",

at interv:1: n greater th:n 2' conth: :n::pt f:r :::t: ' velving; Dg g{gg

,A J..

T..L,,

_T 2.

":f ::::: '<n: i::!:t!:r v:!v::,

l 2.

'!:lve; prc::urf::d with fluid fr;; ; :::: system, 4.

All :;ntefneent :: lation velv;s in hydrestatically teated lines ia Table ?.E.31 'hich peaetrate the prierry centzia ent, and

5.

Dur;e supply and e-h ust # 0!:tf en vo4v:: with re:ili:nt ::t rf;F i

i e.

^4/ 'eck the!' be tested and di-cartreted ODEDASLE per Sur"e!'! nce i

.o,,.,u.t......+. -.._

n.e..,,

.q f.

Main. steam line isolation valves shall be leak tested at least once per 18 months.

g.

Containment isolation valves which form the boundary for the long-term seal of the feedwater lines in Table 3.6.3-1 shall be hydrostati-cally tested at 1.10 P,, 52.9 psig, at least once per 18 months.

h.

All containment isolati:n valves in hydrostatically tested lines in Table 3.6.3-1 which pe 1: rate the primary containment shall be leak tested at least once pa-18 months.

i.

Purge supply and exhaust isolation valves with resilient material seals i

shall be tested and~ demonstrated OPERABLE per Surveillance Requirements 4.6.1.8.2.

J.

The previ:ien: Of Sp::if t::t4:n d.C.2 :r: not :pp!!:-abl: t.:

W4_,, 4. m_ m._,

4. e..,_ _,.,,

1_ e_. 3_. _9. s_, i e_.,_ _ _,.,_,

1. a_ 1_. _9. a_

n a A. 2.

9. 6..

x i

"Unle:: : hyce::tatic te:t 1 required per Table 3.8.3-1.

I HOPE CREEK 3/4 6-4 Amendment No. 48 e

4

+

t es' i

e CONTAINMENT SYSTEMS PRIMARY CONTAINMENT AIR LOCKS LIMITING CONDITION FOR OPERATION
3. 6.1. 3 Each primary containment air lock shall be OPERABLE with:

a.

Both doors closed except when the air lock is being used for normal transit entry and exit through the containment, then at least one air lock door 'shall be closed, and.

b.

An over,all air lock leakage rate :f ?;;; th;n :^ in a ccenknee w.4;% Pr;morv

? t: 0.05 La :t o

en

-,4,.

'a'

~- " ' ' '

contain w.nt t.enkaqe eckTokg Pegmm.

APPLICABILITY: OPERATIONAL CONDITIONS 1, 2* and 3.

ACTION:

a.

With one primary containment air lock door inoperable 1.

Maintain at least the OPERABLE air lock door closed and either restore the inoperable air lock door to OPERABLE status within 24 i

hours or lock the OPERABLE air lock door closed.

j e

2.

Operation may then continue until performance of the next required.

overall air lock leakage test provided that the OPERABLE air lock door is verified to be locked closed at least once per 31 days.

3.

Otherwise, be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and 0

in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

4.

The provisions of Specification 3.0.4 are not applicable.

b.

With the primary containment air lock inoperable, except as a result of an inoperable air. lock door, maintain at least one air lock door closed; restore the inoperable air lock to OPERABLE status within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTOOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, "See Special Test Exception 3.10.1.

C)

HOPE CREEK 3/4 6-5 1

0 e

Q CONTAINMENT SYSTEMS SURVEILLANCE REQUIREMENTS EachprimarycontainmentairlochhallbedemonstratedOPERABLE:

4.6.1.3 Ry ver$ yins sed \\eakaserake. k

+b^

'i d @ '"

8.

"!tt'^ 72 her*: f ^ ?-l eM ' "; :::' C': #^;, ^"'^p' "h^^

+han s u ggg+

nn, g ng 79 kg..e, hy hg4nn

..end (ne mi1+4nlo an+ea ge p. g, ','...a, g_ :I t ^ 5

"",# p"h^"

"0"4#yi"; :::' '.^.3k:g^ ":t^ '" :,th'a

^

2" a+n n n n,4

,7 u.- +qe g--

,c 4,

7,

_mhnn

+hn TMSEF By conducting an overall air lock leakage test :y"

'S.? p:#g, b.

_ ?, t; i t-

'ithi3 J E E H f f7 "; th0t th^ ^V072I' 2i-l^Ck 10 h;90 I

in occordone e vW We Primo.7 co,Agnee.a+

At least once per 6 months #, and

%guke.

rows Precyon 2.

Prior ablishing PRIMARY CONTAINMENT

'RITY when r lock that could affect

-s maintenance n pe pedont the airlock seali init

  • nd 3.

Prior to esta 1 hi IMARY C MENT INTEGRITY when main-tenance has n een performed on the ock that could affect the air sealing capability, a seal test e performed in 1

the overall air lock leakage test. The accP ce teria and test pressure shall be as specified in 4.6...

At least once per 6 months by verifying that only one door in each c.

air lock can be opened at a time.**

1 s

l The prc';!:ier: ef !;::!'ic:tt:r * " 2 2-^

et :;; W eb'e.

  • Exe ptt:- t: A;;;rdi.' f '.^ CT" 50.
    • Except that the inner door need not be opened to verify interlock OPERABILITY when the primary containment is inerted, provided that the inner door interlock is tested within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> after the prir.ary containment has been de-inerted.

HOPE CREEK 3/4 6-6

l

+

CONTAINMENT SYSTEMS l

PRIMARY CONTAINMENT STRUCTURAL INTEGRITY 1

I LIMITING CONDITION FCR OPERATION 1

3.6.1.5 The structural integrity of the primary containment shall be maintained at a level consistent with the acceptance criteria in Specification 4.6.1.5.1.

APPLICABILITY: OPERATIONAL CONDITIONS 1, 2 and 3.

7 ACTION:

With the structural integrity of tho ;.rimary containment not conforming to the above requirements, restore the structural integrity to within the limits within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or be in at least HOT SHUTOOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

1 SURVEILLANCE REQUIREMENTS 4.6.1.5.1 The structural integrity of the exposed accessible interior and exterior surfaces cf the primary containment shall be determined i: 'ng th^ <

fer each Type cente!--eat leeke;? rate test by a "109:1 inspsct h a

'k"+d~"a l

e pege. ed p.4e. te the Type a nr +xm,e

....<3ee, Tse, 4-epect4em ch333 x e ^ ^ * " - c -* ' ^ e k ;c r et^ t ^* + + 0 "e = "" ^^ epp e re a + ^'^;ac 4" eppa="=a"e c*

j n+hme shnnems1 AgnesAs+49n_

4.6.1.5.2 Reports Any abrormal degradation of the primary containment struc-ture detected duW ng the above required inspections shall be reported to the Commission pursuant to Specification 6.9.2 within 30 days. This report shall include a description of the condition of the containment, the inspection pro-cedure, and the corrective actions taken.

1 T AJ SEAT-in acc.ordance WN-Ne 9rimor y cenbinmed leakase Ede. bbs Prestoe HOPE CREEK 3/4 6-8 i

l as 1

ft?r AINHEN* SYSTEMS

'OPYWEL' AND SUPPRESSION CWAMBEP Pt*RGE SYSTEM -

i LIMITING CCR' ITION FOR OPERATIONS 1

4 J

i 1

3.6.1.8 The drywell and. suppression chamber purge system, including the 6-Inch nitrogen supply.ine, may be in operation for up to 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> each 365 l

days with the supply and exhaust. isolation valves in one supply line and one exhaust line open for containment prepurge cleanup, inerting, dstr.erting, or pressure control

  • 4 j

iPPLfcABILITY:

OPERATIONAL CONDITICNS 1, 2 and 3.

1 ACT!ON:

a. With a drywell or suppression chamber purge supply and/ur exhaust isoittien i

valve and/or ths ' nitrogen supply valve open, except as permitted above, close the valves (s) or otherwise isolate the penetration (s) within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> y

1 or be'in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

b. With a drywell purge supply or exhaust isolation valve, or a suppression chamber purge supply or exhaust isol. tion valve or the nitrogen supply

)

valve, with resilient material seals having a measured leakage rate 4

E..eeding t...

..... of Surveillance Requirement 4.6.1.8.2, restore the' inoperable valvels) to OPERABLE status within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHtflDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

SVRVEILLANCE REQUIREMENTS 1

4.6.1.8.1 Before being cpened, the drywell and suppression chamber purge supply and exhaust, and nitrogen supply butterfly isolation" valves shall be verified not to have been open for more than 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> in the previous 365 l

days.*

l 4.6,1,B.2 At least once per 6 months **, but no more than once per 92 days ***,

the 26 inch drywell purga supply and exhaust isolation valves and the 24 inch suppression chammer purge supply and exhaust isolation valves and the 6-inch n:trogen supply valve with resilient material seals shall be demonstrated OPERABLE by t ri8 yin; that th: ?:::ur:d 1::.h:;: ;;. t ; i: 1;;; th;.

n : pei-te L, per peaetratier -her precrurized te ?, M.i prig. ;n accordoue oAlde.Prbery 0 C5

runn # c.Ca4 Led =p pater % Pr*p.

Valves cpen for pressure control are not subject to the 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> per 365 l

days limit, provided the 2-inch bypass lir.es are being utilized.

Provided that the valve has not been operated since the previous test.

l Applies only to a valve which has been operated since the previous test.

.....og HOPE CREEK 3/4 6-11 Amendment No.84 l

)

i i

j l

i

~

j

~

i 3/a.6 CONTA!NwfNT SY57185 8ASES a

1 3/4.6.1 # MARY CONTAINMENT 4

3/a.6.1.1 PRIMARY CONTAINMENT INT [CRITY 1

PRIMARY CONTAINMENT INTEGRITY ensures that the release of racicactiv rials from the contairment staosphere will be restricted to those leatage pat 9s and associatec leak rates assumed in the accident analyses.

This rastriction.

in' conjunction with the leakage rate limitation, wn1 limit tr,e site boundary radiation doses to within the Ifmits cf 10 CFR Part 1.00 during accident conottens.

3/4.6.1.2 PRIMARY CONTAf*ENT LEAKAGE

.. usar det.en bosis t.oca moAmW6 P*d WNnad The limitatio an primar/ containment leakage rates ensure that the total i

containment les i

e vefune will not exceed the value assumed in the accident i

i analyses at the accident pressure of 48.1 psig. P. As an added conserva-tisa, the esasured overall integrated leaf. age rate is further limited to less i

a than or equal to 0.75 L during performance of the riodic tests to account for j

possible degradatfon of,the containment Isakage bar f ors between leakage tests.

4' 2m (Ty e. W %

p Operating experience with the main steen line isolation valves has i

indicated that degradation has occasionally...... A in the lea...w.r6 ness of j

the valves; therefore the special requiment for-testing these valves.

' ' ' ~

The surveillance testing for esasuring leakade rates is consistent with tt ---irrt: :f ^;;;rb "? :f 10 !!! ^ rt 50 _i't ^2; rr;tir ;f

---t'r

-'rd " r n' c' r Smt' r th: hP trth; rd 'r

  • 'r t'-'rt s't-- rt n-' 0> Ac, Pr;mory ceab;.med Mg khb%g R.ep.

1asser 3/4.6.1.3 PCIMARY CONTAlfetENT AIR LOCK 5 The limitatit.ns on closure and leak rate for the primary containment air Io su.T locks are required to meet the restrictions en PRDERY CONTAlmENT INTEGRITY h rf and the? ' : ; r-t:':_r-t '--t;: r"

'
= '- f;r--t'r : ?
  • L1 --*

c..n w nut 2.5.1.2. 't: ; r M:0!= r i : :?t_ x x ":r tS N t tM t it tr; ""

t. g 9de h;p
:f tir

= "J.: O f - 5: : M " h *

- Md W -- ad i

i Te.sh % gram +8aiti4a-4Wr**0 " ??t'" "*-*e**^a.

Only one closed door in each air lock is ret: sired to maintain the integrity of the containment, j

3/4.5.1.4 MSTV SEALING SYSTEM 4

Caleviated doses resulting from the maximum leakage allowance for the main i

steaaline isolation valves in the postulated LOCA situations would be a small fraction of the 10 CFR 100 guietiines, provided the main steam line system from the isolation valves w to and including the turbine condenser remains intact.

Operating experience has fadicated that degradation has occasionally occurred in the leak tightness 6f the M51V's such that the specified leakage requirements have not always been maintained eentint.ously. The sealing system will reduce the untreated leakage from the MSIVs when isolation of the primary system and containment is required.

HOPE CREEK l

8 3/4 6 1 4

i

-y6-r,

.'e I

!!?.- A!NvEN' SYSTEM 3

' sAsES

-l 1 4 4 i 's P9:v>JY C0tcAINMEtri STRUCMR. INTEGPi*/

'I This limitation ensures that the struttural integrity of the containment i -

Adl be er.intained comparable to the original. design standards for the lif e of

- the un t,

. Structural integrity is reTaired to ensure that'the containment i

1

. will withstand the maximum pressure of 48,1 psig in the event'of a LOCA.

A nsual :nspection i re.7 o----

-- * ' - ^ - -


-"**d-*~

~

in accoraoncI sach %e.5mor-conWemed 1.cokap ble

~ 43

' :tosar.T'a Tes% Presrun is suGele.n+. y 34 6.1 6 ' ORYWELL mfd StTPPRESSION CHAMBER ItCERNAL PRESSURE 4

i

.he limitations on drywell and suppression chamber internal pressure ensure that the containment peak preseure of 40.1 psig does not exceed the 4

i design prcssure of 62 psig during LOCA conditions or that the external j

pressure differential does not exceed the design maximum external pressure 4

differential of 3 psid. The limit of.0".5 to +1.5 peig for initial positi'e j

s containment pressure will limit the total pressure to 48.1 psig which is less '

l than the design pressure and is consistent with the safety analysis.

j 1

j 3/4.6.1.'F DRYWELL AVERAGE ATR TEMPERATURE i

Tu limitation y d mwell average air temperature ensures that the

- centa;nment peak air temperature does not exceed the design ternperature of

)

340'F during LOCA conditions and in consistent with the safety analysis. The

. 135'r ave 14ge temperature.is conducive to normal and long term operation.

4 3 '4 6.1:8 ORYIELL AND SUPPRESSION CHAMBER PUPGE SYSTEM j

1

.he.500 hourr/365 days limit for the operation of the purge valves and l

1' the 6" nitrogen supply valve during plant Operational Conditions 1, 2 and 3 is I

-intended to' reduce the probabiltty of a LOCA occurtence during the above

)

operational conditions when the applicable combination of the above valves are open.

Blov out panels are installed in the CPCS ductwork to provide additional assurance that the FRVs will be capable of performing its safety function su.bs e gaent to a LOCA.

1.

i..s HOPE' CREEK B 3/4 6-2 Amendment No. 84 1

1 L

i

-w e

~... - -

i d,

~*

' ADMINISTRATIVE CONTROLS J

d.

Erelesive cas Kanitorina i

This program provides centrols for~potentially explosive gas mixtures contained in the Main Condettser of fgas Treatment System. The program shall include the limit for hydrogen concentration in the Main condenser offgas Treatment system and a surveillance program to ensure the limit is maintained. Thi s limit shall be appropriate to the system's design criteria (i.e., whether or not the system is designed to withstand a hydrogen explosion).

The provisions of sucveillance Requiremente 4.0.2 and 4.0.3 are applicable to the Explosive. Gas Monitoring Program surveillance frequencies.

t I

e lhl$Eifff /t f

I

.m r

\\.

HOPE CREEK 6-16a Amendment No.9I t

wt t

i i

+ ". -

'INSFRT-At

$.8.4.e' Primary Containment Leakage Rate' Testing-Program l

j A program'shall be. established, implemente'd, and

'i maintained to comply with the 3eakage rate testing of the containment. as required by 10CFR50.34 (o). and

10CFR50,'AppendixLJ, Option B,

.s modified by approved-a exemptions.

This'programfshall be in accordance with' l

the guidelines contained in Regulatory Guide,1.163, 2

" Performance-Based Containment Leak-Test Program", dated; September 1995..

The peak calculated containment internal pressure for-the design basis loss.of' coolant accident, P.,

i s -~4 8. 1 psig.

l The maximum allowable primary containment leakage rate,.

I i

. L., at P.,

shall be 0.5% of primary containment air l

weight per day, t

i Leakage Rate Acceptance Criteria are:

y i

a.

Primary containment leakage rate acceptance criterion is less than or equal to 1.0 L..

During the first' unit startup following testing in j

accordance with this program, the leakage rate acceptance criteria are less than or equal to 0.6 L.

r 3

for Type B and Type C tests and less than or equal-to 0.75 L. for Type A tests; j

b.

Air lock testing acceptance criteria are:

1 l

1)

Overall air lock leakage rate is less than or d

equal to 0.05 La when tested at greater than or i

i equal to P.,

2)

Seal leakage rate less than or equal to 5 scf per hour when the gap between the door seals is pressurized to 10.0 psig.

The provisions of Specification 4.0.2 do not apply to the test frequencies specified in the Primary Containment Leakage Rate Testing Program.

\\

i The provisions of. Specification 4.0.3 are applicable to i

the Primary Containment' Leakage Rate Testing Program.