ML20005D643

From kanterella
Jump to navigation Jump to search
Forwards Rev 3 to Ecg Signature Page,Rev 2 to Section 5, Fuel Damage/Degraded Core & Rev 1 to Section 6, Fission Product Boundary Failures
ML20005D643
Person / Time
Site: Hope Creek 
Issue date: 11/29/1989
From:
Public Service Enterprise Group
To:
References
PROC-891129, NUDOCS 8912130206
Download: ML20005D643 (9)


Text

.

PUBLIC SERVICE ELECTRIC & GAS COMPANY

12/05/89' DOCUMENT DISTRIBUTION NOTICE PAGE 1 OF 1

TRANSMITTAL: DDG 0111910 DEhK D

UM T

T COPYHOLDER: HECG0065 WASHINGTON, DC 20555-DESCRIPTION: PCR HECG-TOC REV 4 PLEASE INSERT THE FOLLOWING DOCUMENTS INTO YOUR CONTROLLED FILE / MANUAL.

SUPERCEDED DOCUMENTS MUST BE SO MARKED AND PHYSICALLY REMOVED OR DESTROYED.

SHT/

CLASS DOCUMENT ID VOL INST REV STAT TYPE FORMAT QTY PROC HECG-TOC' 000 004 A HECG H

001 f,[

b

.D t

F-2 h PLEASE SIGN AND DATE THIS NOTICE TO ACKNOWLEDGE RECEIPT AND RETURN WITHIN 5 WORKING DAYS TO:

0!.

(

DOCUMENT DISTRIBUTION GROUP TB-2, N04 y p l

COPYHOLDER SIGNATURE:

DATE:

DDG USE ONLY:

DATA ENTRY COMPLETED:

.]

BOPE CREEK GENERATING STATION EVENT CLASSIFICATION GUIDE November 29, 1989

'y CNANGE PAGES FOR REVISION #4 The Table of Contents forms a general guide to the current revision of each section of the Hope Creek Classification Guide.

The changes that are made in this Revision #4 are shown below.

Please check that your revision packet is complete and remove the outdated material listed below.

J ADD REMOVE Enga Descrintion Bayt Page Descriotion Ray.x 1 of'2 T.O.C.

4 1 of 2 T.O.C.

3 thru thru 2 of 2 2 of 2 1 of 2 Sig. 1-18 3

1 of a Sig. 1-18 2

thru thru 2 of 2 2 of 2, 1 of 2 Section 5 2

1 of 2 Section 5 1

thru thru 2 of 2 2 of 2 1 of 1 Section 6 1

1 of 1 Section 6 0

thru thru 1 of 1 1 of 1 0

HC-ECG 1 of 1 i

i

ECG

'I' A 2

\\

~

Pg. 1of2 1

\\\\TRO'-

BOPE CREEK EVENT CLASSIFICATICN

'I 'DB P

TABLE OF CONTE 31TR,0)Y #

sic i

uovember 17, 19 EFFEC'liTVE SECTION TITLE h

re r.o unrs

" O.C.

Table of Contents 4

2 Nov 17, 1989 Sig. 1-18 Section Identification / Signature Page 3

2 Nov 17, 1989 Sig. Att.

ECG Attachments / Signature Page 2'

2 Sept 29, 1989 1.

Introduction

,0 6

May 26, 1989

'ii.

Cross Reference - Event to Requirement 0

9 May 26, 1989 iii.

Cross Reference -' Attachment to Events 1

1 Sept 29, 1989 l

h 1.

REACTOR COOLANT LEAKAGE /LOCA 0

1 May 26, 1989 2.

STEAM BREAK OR SRV FAILED OPEN O

2 May 26, 1989 3.

FAILURE TO SCRAM 0

1 May 26, 1989 4.

LOSS OF DECAY HEAT REMOVAL 0

2 May 26, 1989 5.

FUEL DAMAGE / DEGRADED CORE 2

2 Nov 17, 1989 t

' h.

FISSION PRODUCT BOUNDARY FAILURE 1

1 Nov 17, 1989 a

7.

RADIOLOGICAL RELEASES / OCCURRENCES 0

5 May 26, 1989 8.

NON-RADIOACTIVE LEAX/ SPILL 1

2 Sept 15, 1989 (toxic gas, oil spill, hazmat) 9.

ELECTRICAL POWER FAILURE 1

2 Sept 15, 1989 10.

LCSS OF INTRUMENTS/ ALARMS / COMMUNICATIONS 0

2 May 26, 1989 l-11.

CONTROL ROOM EVACUATION O

1 May 26, 1989 12.

QUAKE / STORMS (earthquake, wind, 0

6 May 26, 1989 floods, etc) 13.

SITE HAZARDS O

5 May 26, 1989 (aircraft crash, missiles, explosions, etc.)

14.

FIRE 1

1 Sept 15, 1989 l

15.

PERSONNEL EMERGENCIES / MEDICAL 0

2 May 26, 1989 16.

SECURITY EVENTS 1

3 Sept 15.,

1989 17.

PUBLIC INTEREST ITEMS 1

3 Sept 29, 1989 TECH SPECS / PLANT STATUS CHANGES 1

5 Sept 15, 1989 t

i HCGS Rev. 4

. ~.. _ _, _.-___.._, _ _._.___ -

.~.

ECG q

T.O.C 1

Q' BOPE CREEK Pg. 2 of 2 EVENT CLASSIFICATION GUIDE TABLE OF CONTENTS - (Continued)

November 17, 1989 EFFECTIVE ATTACHMENT IIILE E

PAGES DATE 1.

Unusual Event 1

9 Aug 18, 1989.

.2.

Alert 0

8 May 26, 1989

-3.

Site Area Emergency 0

8 May 26, 1989 4.

' General Emergency 0

10 May 26, 1989

5. -

Reserved

6. -

CM1 Log (UE/A/SAE) 1 6

Aug 18, 1989 l

' 7 '..

CMi~ Log (GE) 1 7

Aug 18, 1989 8.

CM2 Log 1

12 Aug 18, 1989 9.

Non-Emergency Notifications Reference 1

2 Aug 18, 1989

p..

'One Hour Report - NRC/ Region 0

5 May 26, 1989 V

11.

One Hour Report - NRC/ OPS (Security) 0 5

May 26, 1989 12.

One Hour Report - NRC/ OPS 0

5 May 26, 1989 l

o 13.

Reserved 14.

.Four Hour Report - NRC/ OPS 1

5 Aug 18, 1989 l

L 15.

Four Hour Report - Environmental 1

5 Sept 29, 1989 16. --

Four Hour Report - Spill /Hazmat 0

6 May 26, 1989 17.

Four Hour Report - Fatality / Medical '

1 7

Aug 18, 1989 18.

Four Hour Report - Transportation Accident 0

6 May'26, 1989 19.

Reserved

-20.

Twenty Four Hour Report - NRC/ OPS 1

5 Aug 18, 1989 21.

' Reportable Event - LACT /MOU 0

2 May 26, 1989

-22.

Other/ Engineering 0

3 May 26, 1989 i

/.

Written Reports /LERS/Other 0

7 May 26, 1989 lt

)

l l

HCGS Rev. 4 l

l l

-o-

u

^'.' -

gcq Sig. 1-18 Pg. 1 of 2

/N BOPE CREEE

-()-

SECTION SIGNATURR PAGES EVENT CLhasIFICATION GUIDE November 17, 1989 EFFECT.TVE SECTION TITLE BEY PAGES DATES 1.-

Introduction 0

6 -

May 26, 1989 ii.

Cross. Reference - Event to Requirement 0

9 May 26, 1989 iii.

Cross Reference - Attachment to Events 1

1 Sept 29, 1989

-1.

REACTOR COOLANT LEAKAGE /LOCA 0

1 May 26, 1989 1

2.

STEAM BREAK OR SRV FAILED OPEN O

2 May 26, 1989 3.

FAILURE TO SCRAM 0

1 May 26, 1989 4.

LOSS OF DECAY HEAT REMOVAL 0

2 May 26, 1989 5.

FUEL DAMAGE / DEGRADED CORE 2

2 Nov 17, 1989 i

6.-

FISSION PRODUCT BOUNDARY FAILURE 1

1 Nov 17, 1989 7.

RADIOLOGICAL RELEASES / OCCURRENCES 0-5 May 26, 1989 NON-RADIOACTIVELEAK/SPIk1 1

2 Sept 15, 1989 8.

(toxic gas, oil spill, hazmat) i 9.

ELECTRICAL POWER FAILURE 1

2 Sept 15, 1989

10. -

LOSS OF INTRUMENTS/ ALARMS / COMMUNICATIONS 0

2 May 26, 1989 l

'11.

CONTROL ROOM EVACUATION O

1 May 26, 1989 12.

QUAKE / STORMS (earthquake, wind, floods, 0

6 May 26, 1989 etc) 13.

SITE HAZARDS 0

5 May 26, 1989 i

(aircraft crash, missiles, explosions, etc.)

14.

FIRE O

1 May 26, 1989 t

15.

PERSONNEL EMERGENCIES / MEDICAL 0

2 May 26, 1989 l

16..

SECURITY EVENTS 1

3 Sept 15, 1989 17.

PUBLIC INTEREST ITEMS 1

3 Sept 29, 1989 18.

TECH SPECS / PLANT STATUS CHANGES 1

5 Sept 15, 1989

'O HCGS Rev. 3 L

]

i ECG y

s.

t SECTIONS i-18 Pg. 2 of 2 SIGNATURE PAGE i

l Prepared By:

'b. Enm.w s t[r, 6 j

(If Editorial Revisions Only, Last Approved Revision)

'Ddte Reviewed By:

/-

L%

h/'/h S,tation Qualified Reviewer Date Significant afety Issue fr

( ) Yes (.

no i

Reviewed By*

///7/87 Departient Managttr Date i

Reviewed By:

)[L

_f//7//s

[

Emergeno? Preparedness Manager Date

/G ig Reviewed By:

N/A General Manager - Quality Assurance / Safety RevicW

-Date (If Applicable)

{

SORC Review and Station Approvals 79-l.3o W %

.~ i,2 Mtg. No.

Salem Chairman Mtg. No.

HgC

~e' Chairman

'llfjaf@9 Date Dalfe

-, /t General Manager - Salem Gen a

n

'e

- Hope Creek ll JM D/ ye Date HCGS Rev. 3

. ~. -. - - - -

,W'M

(

'e J-i 1

v Ns

. s _.e ECG FUEL DAMAGE / DEGRADED CORE 4C'P",, *2-i SECTION 5 INiilAflNG mail 0f6 A. FUEL DAllAGE INDICATI0ffS B. SEVERE 1855 0F FUEL C1 ADDING C. DECRADED CORE WITN WIBICATION OF P055fB12 LASS OF C00tAttE CN F_

W W.

W W

W W

l Fuel cloddeg demoge is in& coted DAPA RCS Sompte Volid t!Qf clorm on any DAFA RCS Somsde l

by cny of the fonoweg:

> 200 R/hr shows del-137 of the tono.ing

> 5000 R/hr shows del-13?

I

> 300 #d/g Process Monitors:

> 1000 JC/g l

Esceeding lodme Sphe Beweh WN SIM UNE (C5-91) on RCS Specific Activity es THEN THEN RnD te IRtP THEN THEN l

> 4 pCi/g del-13:

OR W (as determmed by sample) g g g3 l

0 11 WSN isolot.on present OFFCAS PREIREAlutNT ucraTOR OR l

(9Rv621 / 9Rx622)

OrFCAS PREIREAfufNT MONITOR

  • *'*1 (9Rx629 / 9RX622)

> 6 OE +03 mR/hr M OU EALS l c,c3

, ",.cet et2

,ggy I

I YHEN I

I ime i

Il0IU N $NSS/EDO judgernent in6 cotes probable fuel foikne, comgdetien i

If the Offges Activity a.s not fuct of chemistry somp4 should not l

related but es due to some other restrict / delay classification.

phenomeno (te. RCS chemistry control) refer to ECG Section 7 for Radiological l

Releases prior to Classification.

l t!QlE:

l ff the Offgos Activdy as not fuel

,eloted m a d.e to - ote,er phenorneno (ie. RCS chemistry controt) i refer to ECG Section 7 for Radiciogicot I

  1. efeoses prior to Classificotson.

I L_ _

tl0ilflCAll0N/

REFER TO REFER TO REFER TO HCG ATTACleaEkT I ATTACHMENT 2 AT14CMutNT 3 RE{0RTING REV. 2 Unusuat EvER AtInt grE AllEA EMERGENCY 9

a w.

m,

,t s

ECG FUEL DAMAGE / DEGRADED CORE MC "v'2 2

SECTION 5 IRRADIATED OR SPENT FUEL DAMAGE

!PJIIIAIIPJG D. FtfEL MANDtJNG ACCIDENT WITM RADlotDGICAL E. WAJOR IRRADIATED PtfEl. BAMACR TffW RAD 0DIAGICAL StE12ASE CONCHilCINS RE11ASE TO THE REACTOR DUlfDING FRott EXCEEDif0G (OR PRO 3ECTED TO EXCEED) TNT TIIRESH0t3 BOSE BRRADIATED F'JEL RATES AT TNE afEA FOR A SITE AREA ElfEltGEleCY I ~~

F F

fuel Handling Accident Fuel Pool Water tevet with is decreosmg roslsdly i

l irrodioted foet domoge in on imcontrcHed manner I

I mo Any of the fotooing Process or Area Rod Morwtors l

indscolmg on ' crease of m

EALS l

~

NEW FUEL CRITICMJTY RAD (R9si2/R9 sis) l SPENI FULL W0t. Em4P AREA RAD (R9103) l SrtNT IUEL POOL STORACE AREA RAD (R9707) 1 REFUEL FLR ExH DUCT RAD I

(R9627/R9628/R9629) i THEN I

y I

nel I

"e

'I l

Fues Pool Water Level Rodelogicos Reieases is et or below the top are measured, proMed I

of irodioted fuet in er anotyred to esceed the Spent Fuel Storage the lirnits of ECG rocks Section 7 for o l

Sde Area feyceL ilENf l

THEN' I

t_ _

W R TO REFER TO NOTIFICATION /

LTTaCHMENT 2 ATTACMMENT 3 REPORiiNG Attaf SrfE AnEA EMERGDIET ggg REV. 2

,g"

,a3 y

I f W8km

,./V-

g G

O M

FISSION PRODUCT BOUNDARY FAILURES

[L e SECTION G NJO Ihe foNoemg Con 6 tens / EALS indicate Fodure of a f.smen product tensory Pg. 1 of 1.

Any two boundary Foilures represents a CENERAL EMERGENCY conddsori.

Monster for these con 6tions ofter ony sendle boundary Fodure.

A. SEVERE LOSS OF FUEL CIADDING B. LOSS OF RPV INTEGRITY C. IASS OF PRIMARY CONTAINMENT -

l!4tilATING

t. CONTA!NilENT
2. RCS ANALYST $
3. PRO G SS HONITORS
t. RCS / CONT. INDtCAT10ftS OF A IDCA
2. SNSS/EDO ANALYSIS
1. INDICATIONS OF BItEACE
2. SMS5/Epe Af8AR.TSIS C0iBil0NS ti1CII RADtATION Sit 0WS FAllID INDICAt10NS THAT ItPT gaffECftffY OF CONTAINIfENT OF CONT. FAIL 5EE Oft FUEL IS IDST StetetNENT Falt.tfilt '

F-l w

w w

w w

w w

w l

OAPA RCS Somple Valid (M24 oloren on gny RPV Water teve4 Octb of the fosommg-SNSS/EDO judgement in6cobons of Pnmary SNSS/EDO judgament

> 200 R/hr shows 0(t-131 of the foso.ing connot be maintoined

1. ORYWELL PRESSURE H that RPV integedy is Contomrnent fodure by that Prwnary I

> 300 pCi/g Process uorwtors.

above -ID inches

2. RPV Water t.evet lost 2 or vnore otheroese Contomment forture.

<i25 inches and une pioined conditions.

hos eccorred kN STM tlNE (CS-61) decreosng such os-OR 1

RAD H TRIP is on,n.nent OR INOP Drywet Pressure decreasing I

ca

- =SSss 5,,

.et-usiv isop2t.on peesent gev,e 4.c.,os ng OR 08 l

OFFCAS PRETREAfuENT MONITOR (9RX621 / 9RX622)

Rodestion tek or EALSl HICH ALARM Surrp or %or levels OR incr-l CACS ALARM for HICH H2 I

I i

8 A

B C

I I

I I

Any Too Frasion Product i

Doundaries have faded I

A est 11 N

I i

l 1

A and C QB l

B oM C l

no L_

norrorioN/

ggy, nccs

. PEI'ORIlf h1 REV. t CENERAL EME9CENCY e

v:v-e

.- M