ML20197H594

From kanterella
Jump to navigation Jump to search
Proposed Tech Specs Pages,Revising TS Section 4.2.2, Terrestrial Ecology Monitoring, by Changing Wording to Include Completion of Salt Drift Monitoring Program
ML20197H594
Person / Time
Site: Hope Creek 
Issue date: 12/19/1997
From:
Public Service Enterprise Group
To:
Shared Package
ML20197H590 List:
References
NUDOCS 9712310327
Download: ML20197H594 (3)


Text

.

Document Control-LDesk LR-N970670

-Attachment 3-

'LCR H97-18 HOPE CREEK GENERATING STATION FACILITY OPERATING LICENSE NPF-57 DOCKET NO. 50-354-CHANGE TO TECHNICAL SPECIFICATIONS SECTION 4.2.2 " TERRESTRIAL ECOLOGY MONITORING" -

ENVIRONMENTAL PROTECTION PLAN TECHNICAL SPECIFICATION PAGES WITH PROPOSED CHANGES The following Environmental Protection Plan pages are affected by this change request:

EPP Section Page Section 4.<

?

Page 4-2 & 4-3 F

Page 1 of 1

'9712310327 971219 PDR ADOCK 05000354 P-PDR

t.... l.

wrrestrial Eccicgy Lcr,itcring

~

0

  • itt erilicent will implement the Salt C'rif t nionitoring Program to essess ftheimpactsofcoolingtcursoitdriftontheenvironmentirthePCCS vit.d rity trevided to NRC by letter dead Lerch R,1964 frora Robert L. Ititti.

Peblic Cervice Electric & Gas Co., to A. Scbeencer, U.S. Nuclear Reguletcry Cernrission.

The monitering pry rerr. shall com.ence one year prior tc the erset of ecweredt! cpuration of the HCGS ano ir.cloce ice-power testing and operational date up tc thret p6rs f roni receipt of license cr crtil such earlier tire tht.t the licensee can demor. strati that the objectives of the study have been fulfillec. Ar.nual monitoring reports shall be sebeitted to tho NRC for review.

The licensee may make changes it: the seit drift monitoring procedures witbout prior Comission approvel cr.10ss the proposed change affects tne program objectives describec in the' introduction to the 5 alt Drift Honitoring Program. Chances in the procedures, for example, chaliges which atit ct sampling frequency, lccation, gear, or replication, shall be recorded.

Records shall describe the changes made, the reasoris for i.,aking the changes, and a statement shoving how continuity of the study will be affected. Any modificatiers er changes of the monitoring progran, once initiated, shall be governed by the need to maintain consister.cy with previously used procedures so' that direct comparisons of data are technically valid. Such modificatiers or changes shall be justified and 4-2

e

.t'e supported by adequate cor:pretive sarrpling programs or studies derocr.strating

- the comparability ct - results or. which provide a basis fer r.aking ad,1ustments that weuld territ direct comparisons. The annLul report should describe punitsrtog procedures at.c cl.crige:; in such procedures made durirs the report

. pt ri e r-,

"PSE&G has completed the implementation of the Salt Drift Monitoring Program to assess the impacts of cooling tower salt drift on the environment in the HCGS vicinity.

Results of the study were submitted to the NRC in a report entitled " Operational Summary Report for Hope Creek Generating Station Salt Drift Monitoring Program, January 1987 to March 1989."

This report was submitted on October 10, 1989 (NLR-N89201).

Results of the study indicate that onlv minor, localized effects of cooling tower dritt deposition are M0p occurring.

Higher deposition rates potentially 7

attributable to the cooling tower were measured at only one location, which is on station property at a distance of 0.4 km southeast of the cooling tower.

The 2

salt deposition rate at this site is 113 mg/m / month, which is well below the deposition levels that have been reported to cause vegetative damage of 10.000 2

mg/m / year.

Hope Creek Generating Station is surrounded by extensive areas of tidal salt marsh and the nearest uplands are located approximately three 1

miles to the east, therefore no significant adverse impacts will occur as a result of cooling tower operation.

PSE&G has satisfied the commitments under this requirement. No further monitoring is required."

43 I

...-