Braidwood Station, Units 1 and 2 - NRC Temporary Instruction 2515/191, Mitigation Strategies, Spent Fuel Pool Instrument and Emergency Preparedness Inspection Report 05000456/2018011 and 05000457/2018011
ML18033A711
Person / Time
Site: Braidwood  Constellation icon.png
Issue date: 02/02/2018
From: Stone A M
Division Reactor Projects III
To: Bryan Hanson
Exelon Generation Co, Exelon Nuclear
References
IR 2018011
Download: ML18033A711 (12)


Text

February 2, 2018

Mr. Bryan Senior VP, Exelon Generation Company, LLC President and CNO, Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555

SUBJECT: BRAIDWOOD STATION, UNITS 1 AND 2-NRC TEMPORARY INSTRUCTION 2515/191, MITIGATION STRATEGIES, SPENT FUEL POOL INSTRUMENTATION AND EMERGENCY PREPAREDNESS INSPECTION REPORT 05000456/2018011 AND 05000457/2018011

Dear Mr. Hanson:

On January 19, 2018, the U.S. Nuclear Regulatory Commission (NRC) completed a Temporary Instruction (TI) 2515/191, "Inspection of the Implementation of Mitigation Strategies and Spent Fuel Pool Instrumentation Orders and Emergency Preparedness Communication/Staffing/Multi-

Unit Dose Assessment Plans" inspection at your Braidwood Station, Units 1 and 2. The NRC inspectors discussed the results of this inspection with Ms. A. Ferko and other members of your staff. The results of this inspection are documented in the enclosed report. The inspection examined activities conducted under your license as they relate to the implementation of mitigation strategies and spent fuel pool instrumentation orders (EA-12-049 and EA-12-051) and Emergency Preparedness Communication/Staffing/Multi-Unit Dose Assessment Plans, your compliance with the Commission's rules and regulations, and with the conditions of your operating license. Within these areas, the inspection involved examination of selected procedures and records, observation of activities, and interviews with station personnel. The NRC inspectors did not identify any findings or violations during this inspection. This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with 10 CFR 2.390, "Public Inspections, Exemptions, Requests for Withholding."

Sincerely,/RA/

Ann Marie Stone, Team Leader Technical Support Branch Division of Reactor Projects Docket Nos. 50-456; 50-457 and 72-073 License Nos. NPF-72 and NPF-77

Enclosure:

IR 05000456/2018011; 05000457/2018011 cc: Distribution via ListServ