IR 05000456/2022501

From kanterella
Jump to navigation Jump to search
Emergency Preparedness Biennial Exercise Inspection Report 05000456/2022501 and 05000457/2022501
ML22076A055
Person / Time
Site: Braidwood  Constellation icon.png
Issue date: 03/21/2022
From: Patricia Pelke
NRC/RGN-III/DRS/OLB
To: Rhoades D
Constellation Energy Generation, Constellation Nuclear
Garza M
References
IR 2022501
Download: ML22076A055 (8)


Text

March 21, 2022

SUBJECT:

BRAIDWOOD STATION - EMERGENCY PREPAREDNESS BIENNIAL EXERCISE INSPECTION REPORT 05000456/2022501 AND 05000457/2022501

Dear Mr. Rhoades:

On March 4, 2022, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Braidwood Station and discussed the results of this inspection with Mr. Gregory Gugle, Site Vice President, and other members of your staff. The results of this inspection are documented in the enclosed report.

No findings or violations of more than minor significance were identified during this inspection.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely, Signed by Pelke, Patricia on 03/21/22 Patricia J. Pelke, Chief Operations Branch Division of Reactor Safety Docket Nos. 05000456 and 05000457 License Nos. NPF-72 and NPF-77

Enclosure:

As stated

Inspection Report

Docket Numbers: 05000456 and 05000457 License Numbers: NPF-72 and NPF-77 Report Numbers: 05000456/2022501 and 05000457/2022501 Enterprise Identifier: I-2022-501-0007 Licensee: Constellation Energy Generation, LLC Facility: Braidwood Station Location: Braceville, IL Inspection Dates: February 28, 2022 to March 04, 2022 Inspectors: D. Betancourt-Roldan, Senior Resident Inspector M. Garza, Emergency Preparedness Inspector G. Hansen, Senior Emergency Preparedness Inspector T. Iskierka-Boggs, Operations Engineer Approved By: Patricia J. Pelke, Chief Operations Branch Division of Reactor Safety Enclosure

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting an emergency preparedness biennial exercise inspection at Braidwood Station, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.

List of Findings and Violations

No findings or violations of more than minor significance were identified.

Additional Tracking Items

None.

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs)in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html.

Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.

REACTOR SAFETY

71114.01 - Exercise Evaluation

Inspection Review (IP Section 02.01-02.11) (1 Sample)

(1) The inspectors evaluated the biennial radiological emergency preparedness exercise on March 1, 2022. The exercise scenario simulated an event at the Braidwood Station that initiated with the declaration of an Alert in response to an earthquake that resulted in a loss of offsite power. The scenario conditions simulated the escalation of the significance of the event, requiring the declaration of a Site Area Emergency, for a steam generator tube rupture and loss of heat sink. Each emergency classification was communicated to the required state and local government agencies.

71114.08 - Exercise Evaluation - Scenario Review

Inspection Review (IP Section 02.01 - 02.04) (1 Sample)

(1) The inspectors reviewed and evaluated the proposed scenario for biennial emergency plan exercise on January 21,

OTHER ACTIVITIES - BASELINE

===71151 - Performance Indicator Verification The inspectors verified licensee performance indicators submittals listed below:

EP01: Drill/Exercise Performance (DEP) Sample (IP Section 02.12) ===

(1) January 01, 2021 through December 31, 2021 EP02: Emergency Response Organization (ERO) Drill Participation (IP Section 02.13)

(1 Sample)

(1) January 01, 2021 through December 31, 2021 EP03: Alert And Notification System (ANS) Reliability Sample (IP Section 02.14) (1 Sample)
(1) January 01, 2021 through December 31,

INSPECTION RESULTS

No findings were identified.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

On March 4, 2022, the inspectors presented the emergency preparedness biennial exercise inspection results to Mr. Gregory Gugle, Site Vice President, and other members of the licensee staff.

DOCUMENTS REVIEWED

Inspection Type Designation Description or Title Revision or

Procedure Date

71114.01 Corrective Action AR 04325067 BRW-EP-2020-NRC-SIM-TSC Failed Objectives/DEP Failure 03/09/2020

Documents AR 04325079 BRW-EP-2020-NRC-TSC-SIM Failed DCS 03/09/2020

AR 04325084 BRW-EP-2020-NRC-OSC Failed DCS 03/09/2020

AR 04440081 BRW-EP-2021-OYE-OSC Failed Demonstration Criteria 08/11/2021

AR 04440097 BRW-EP-2021-OYE-MCR/SIM Failed Demonstration Criteria 08/11/2021

AR 04440111 BRW-EP-2021-OYE-TSC Sat with Comments and Additional 08/11/2021

Issues

AR 04475692 Braidwood Practice Exercise - EOF Performance 02/03/2022

AR 04475781 EP Pre-Exercise Control Room Simulator Learnings 02/03/2022

AR 04476119 EP Pre-Exercise Drill Critique Learning for the TSC 02/04/2022

AR 04476121 EP Pre-Exercise Drill Critique Learning for the TSC 2/2 02/04/2022

Miscellaneous Emergency Preparedness Drill and Exercise Reports (Sample) 02/01/2020 -

2/28/2022

EP-AA-1000 Standardized Radiological Emergency Plan 33

EP-AA-1001, Emergency Action Levels for Braidwood Station 6

Addendum 3

Procedures EP-AA-111 Emergency Classification and Protective Action 23

Recommendations

EP-AA-112 Emergency Response Organization (ERO) / Emergency 22

Response Facility (ERF) Activation and Operation

EP-AA-112-400 Emergency Operations Facility Activation and Operation 15

EP-AA-114 Notifications 17

EP-MW-114-100 Midwest Region Offsite Notifications 20

71114.08 Miscellaneous RS-21-119 Braidwood Station 2022 Emergency Preparedness Biennial 12/17/2021

Exercise Scenario

71151 Miscellaneous Monthly Data Alert Notification System Reliability 01/01/2021 -

Elements for NRC 12/31/2021

ROP Indicator

Monthly Data Emergency Response Organization Readiness 01/01/2021 -

Elements for NRC 12/31/2021

ROP Indicator

Monthly Data Drill/Exercise Performance 01/01/2021 -

Inspection Type Designation Description or Title Revision or

Procedure Date

Elements for NRC 12/31/2021

ROP Indicator

6